Cell Type HR-4/5FAUP
Specifications
Type : Nickel-Metal Hydride Battery
Size : 4/5FA
Typical
1950mAh
1800mAh
Capacity
1)
Minimum
18.1 mm
Nominal Voltage
1.2V
Charging Current x Time
Fast Charge
Fast Charge
2)
2)
1950 mA x about 1.1h
0°C - 40°C
Charge
Condition
Discharge Condition
0°C - 50°C
43.2 mm
Less than
30days
Ambient Temp.
-20°C - 50°C
-20°C - 40°C
-20°C - 30°C
About5 mΩ(at 1000Hz)
About 39 g
Storage
Condition
Less than
90days
Less than
1year
Internal Impedance
3)
(after discharge to E.V.=1.0V)
Weight
4)
Size
4)
:(Diameter) x (Height)
18.1(D) x 43.2(H) mm
1)Single cell capacity under the following condition.
Charge : 195mA×16h, Discharge : 390mA(E.V.=1.0V) at 20°C
2)Use recommended charging system.
3)After a few charge and discharge cycles under the above 1) condition.
4)With tube.
D
H
18.1 mm
43.2 mm
Dimensions
(with tube)
Typical Characteristics
Charge
Discharge
1.6
1.5
1.8
Charge : 2A (-∆V=10mV)
Ambient Temp. : 0°C,20°C,40°C
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0.4A 2A
5A
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0°C
20°C
40°C
10A 15A
Charge : 2A (-DV=10mV)
Rest : 1h
Discharge : 0.4A,2A,5A,10A,15A (E.V.=0.6V)
Ambient Temp. : 20°C
0
10
20
30
40
50
60
70
80
0
250 500 750 1000 1250 1500 1750 2000 2250
Charge Time (min)
Discharge Capacity (mAh)