5. Keep out of direct sunlight and heat radiation sources. It may cause fire.  
6. Install it in a place with good ventilation.  
7. Avoid aiming the controller directly towards extremely bright objects such as sun.  
8. Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be  
placed on the apparatus.  
9. The Mains plug is used as a disconnect device and shall stay readily operable at any time.  
FCC Statement  
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions :  
1) This device may not cause harmful interference, and  
2) This device must accept any interference received including interference that may cause undesired operation.  
Caution  
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part  
15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when  
the equipment is operated in a commercial environment.  
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in ac-  
cordance with the instruction manual, may cause harmful interference to radio communications. Operation of this  
equipment in a residential area is likely to cause harmful interference in which case the user will be required to  
correct the interference at his own expense.  
IMPORTANT SAFETY INSTRUCTIONS  
1. Read these instructions.  
2. Keep these instructions.  
3. Heed all warnings.  
4. Follow all instructions.  
5. Do not use this apparatus near water.  
6. Clean only with dry cloth.  
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.  
8. Do not install near any heat sources such as radiators, heat registers, or other apparatus (including amplifiers) that  
produce heat.  
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one  
wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third  
prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for  
replacement of the obsolete outlet.  
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the  
point where they exit from the apparatus.  
11. Only use attachments/accessories specified by the manufacturer.  
12. Use only with cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with  
the apparatus.  
13. Unplug this apparatus when a card is used. Use caution when moving the cart/ apparatus  
combination to avoid injury from tip-over.  
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any  
way, such as powersupply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus,  
the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.  
English _ 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
contents  
6
7
8
9
Features  
What’s included  
At a Glance  
PRODUCT INTRODUCTION  
Cable Color Scheme  
6
10 Installing the rear template  
11 Cable Selection  
12 Bypass Diode Connection  
12 I/O Connection  
INSTALLATION AND EXTERNAL  
CONNECTION  
14 External Reader Connection  
10  
15 Basic Operations  
16 Wiegand Output Setup  
16 Initialization  
INITIALIZATION  
17 Forced Initialization with External Line  
17 Hardware Forcible Initialization  
15  
READER MODE SETUP  
18  
18 Reader Mode Setup (RF ONLY)  
19 Reader Mode Setup (RF + P/W)  
19 Reader Mode Setup (PIN ONLY)  
20 Reader Mode Setup (RF/PIN Combination  
Mode)  
20 Enabling Keypad Input for the Card Number  
21 To register cards in RF ONLY mode  
21 RegIsterIng cards In a combInatIon oF RF  
and P/W modes  
USER MANAGEMENT  
22 to regIster cards In PIn mode  
22 regIsterIng cards In rF card / PIn combInatIon  
mode  
21  
23 to delete a regIstered card or PIn number  
24 Duress Alarm  
24 To specify the retry count for an unregistered  
ID  
BASIC SETUP  
25 To specify the keypad input suspension time  
if the retry count with an unregistered ID  
exceeds the limit  
25 To specify the delayed start time in Secure  
mode  
24  
26 To specify the operation time of the Door  
Contact Sensor  
26 To specify the limited time for the keypad  
input  
27 To specify the alarm output port for the  
dismantled device  
27 To open or close the entry door  
28 To set or release the QUICK mode  
28 To set or release the Toggle mode for the  
door relay  
29 To specify the output time if the card is  
authenticated  
4_ Contents  
Download from Www.Somanuals.com. All Manuals Search And Download.  
30 To specify the output time if the card is not  
authenticated  
I/O TIME SETUP  
30 To specify the Duress TTL output  
31 To specify the alarm output for an input error  
of the Door contact Sensor  
31 To specify the alarm operation time for AUX 1  
32 To specify the alarm operation time for AUX 2  
32 To specify the alarm operation time for AUX 3  
33 To activate or deactivate the door relay by  
the Door Contact Sensor  
29  
34 To specify the TTL output operation mode  
34 To set the chime bell function  
35 To specify the chime bell operation time  
35 To specify the input mode for AUX 1  
36 To specify the input mode for AUX 2  
36 To specify the input mode for AUX 3  
37 To specify the input mode for the Exit Button  
37 To specify the input mode for the Door  
Contact Sensor  
ADVANCED SETTING  
34  
38 Mute  
38 To specify the use of the tamper alarm  
39 To check the output specified for a registered  
card user  
ADDITIONAL FEATURES  
39 To check the output specified for an  
unregistered card user  
40 To check the output specified for the Door  
Contact Sensor alarm  
40 To check the output specified for AUX 1  
41 To check the output specified for AUX 2  
41 To check the output specified for AUX 3  
38  
42 InItIal Values  
43 FunctIon codes  
OTHER INFOR4MAT2ION  
45 Troubleshooting  
TROUBLESH4OOT5ING  
PRODUCT SPECIFICATIONS  
50  
50 product specifications  
English _ 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
product introduction  
FEATURES  
This controller is best designed for a single entry door control (single door access control).  
It can store up to 512 cards including the Master Card that enables you to register, delete or set various user cards to  
your preference.  
This product features 5 external ports that can be connected to the Exit button, Door Contact Sensor, Motion Sensor,  
and Fire Sensor. It also has 2 relay outputs that can control the door lock and alarm relay. The dual tamper switch triggers  
an alert if the product is forcibly disassembled.  
You can use the keypad to configure all settings as necessary.  
This product is designed for a standalone system.  
Single Door Access Control  
You can use the RF card (SSA-C100,SSA-C110,SSA-C120) to control a single door.  
User Registration  
You can register a total of 512 cards including the Master Card.  
Keypad Registration  
SSA-S2000 is equipped with the built-in keypad that you can use to register, delete cards or configure various settings  
independently.  
Buzzer On/Off  
With the help of various buzzer tones, you can check the operation status and the current settings and results of the  
product.  
External I/O Pins  
SSA-SS2000 has 5 input ports and 4 output ports installed (2 relay and 2 TTL outputs).  
The input ports can receive signals from the Exit button and the Door Contact sensor, while the two relays can be  
connected to the door lock and the alarm device. One of the TTL output ports can function as a chime bell in connection  
with the door bell.  
Duress Alarm  
This is used in a situation where you should open the door inevitably by a robber insisting to do so. Entering the two-digit  
ENT  
duress alarm password with pressing the  
button and recognizing the registered card (or card number)  
can open the door normally, while you can set to produce the TTL signal notifying the door is forcibly  
opened.  
Limited Access Tries for an Unregistered Card  
You can specify the limit of times to try accessing the door, and the suspended operation time of the keypad for an  
improper access.  
6_ Product Introduction  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WHAT’S INCLUDED  
Check if the following items are included in the product package.  
Main Unit  
Template  
O-rings (x5)  
xœŠ’Gnœ‹Œ  
3.5 x 40mm Screws (x4)  
3.5 x 12mm Screws (x4)  
6 x 30mm Plastic Anchors (x4)  
Diodes (x2)  
(UF4004, 1N4001~4007)  
Quick Guide  
tˆš›Œ™Gjˆ™‹  
Master Card (x1)  
Cables (x4)  
CD Manual  
English _ 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
product introduction  
AT A GLANCE  
Front View  
System Status LED  
Keypad  
Indicates the operation status of the system.  
Use this to configure or release settings as appropriate, or enter a card  
number.  
8_ Product Introduction  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CABLE COLOR SCHEME  
2-PIN Connector  
I/O Pins  
Signal  
Signal  
Cable Color  
Cable Color  
Power (+12V)  
DC +12V  
Red  
Earth-grounding  
GND(-)  
Black  
10-PIN Connector  
I/O Pins  
Door Control Relay (NC)  
Door Control Relay (COM)  
Door Control Relay (NO)  
Alarm Relay (NC)  
Alarm Relay (COM)  
Alarm Relay (NO)  
Exit Button  
NC(RL1)  
COM(RL1)  
NO(RL1)  
NC(RL2)  
COM(RL2)  
NO(RL2)  
EXIT  
Blue with White stripes  
Gray with Red stripes  
White with Red stripes  
Purple with White stripes  
White  
Purple  
Orange  
Door Contact Sensor  
Aux Input #1  
CONTACT  
AUX IN 1  
AUX IN 2  
Yellow with Red stripes  
Green  
Aux Input #2  
Green with White stripes  
7-PIN Connector  
I/O Pins  
Signal  
Cable Color  
Wiegand Data Input 0  
Wiegand Data Input 1  
TTL Output  
DATA_0  
DATA_1  
TTL  
Pink  
Sky blue  
Orange with White stripes  
Brown with White stripes  
Green with Red stripes  
Blue with Red stripes  
Yellow with Red stripes  
Chime Bell Output  
Aux Input #3  
CHI  
AUX IN 3  
RESERVED 1  
RESERVED 2  
3-PIN Connector  
I/O Pins  
Signal  
Cable Color  
RESERVED 1  
RESERVED 2  
RESERVED 3  
Black with White stripes  
Red with White stripes  
Black  
English _ 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
installation and external connection  
INSTALLING THE REAR TEMPLATE  
6-32 hole  
O-ring  
O-ring  
1/2” hole  
O-ring  
O-ring  
6-32 hole  
O-ring  
1.52"(38.5mm)  
1.52"(38.5mm)  
3.03"(77mm)  
Once the main unit is fixed with the rear panel, it will not be loosened. Please check if the device is operating before fixing  
it. If you try to remove the rear panel once it is fixed, the lock parts of the rear panel will break, resulting in a situation  
where the whole rear panel must be replaced.  
J
10_ Installation and External Connection  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CABLE SELECTION  
DC12V  
Power Supply  
Sensor Input  
RF Reader  
Lock/Alarm  
Item  
Power (DC12V)  
Cable Type  
Belden #94099, 18 AWWG 2 Connducttor, Unnshielded  
1
2
DC Power This Product  
Belden #9512, 22 AWG 4 Conductor, Shielded  
Belden #9514, 22 AWG 8 Conductor, Shielded  
Reader (power and data)  
External Reader This Product  
Door Contact Sensor  
Exit Button  
Sensor Input  
Belden #9512, 22 AWG 4 Conductor, Shielded  
Belden #9514, 22 AWG 8 Conductor, Shielded  
3
4
Input This Product  
Door Lock,  
Alarm Device  
Belden #94099, 18 AWWG 2 Connducttor, Unnshielded  
Lock (Alarm) This Product  
J The cables should be thick enough to allow the maximum current consumed by the reader.  
English _ 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
installation and external connection  
BYPASS DIODE CONNECTION  
If you connected an inductor (door locks or alarm device) to the output relay, there should occur a voltage surge while the  
inductor is turning on and off. If you do not connect a reverse diode to the relay, the surge voltage will cause damage to the  
electric circuit of the controller. To reduce this surge, it is recommended to connect a reverse diode between the devices.  
DC+  
Cathode  
Anode  
1N4004 ~ 1N4007 or equiv.  
DC-  
Lock/Alarm  
I/O CONNECTION  
Input Connection  
Door Contact Sensor: Green with red stripes, GND  
Exit Button: Orange line, GND  
Door Contact Sensor  
Black-  
Red+  
DC + 12V  
Power Supply  
Exit Button  
PUSH  
1. Connect the DC 12V(+) of the power supply unit to the red line.  
2. Connect the GND(-) of the power supply unit to the black line.  
- Exit Button Connection  
1. Connect one line of the Exit button to the orange line.  
2. Connect the other line of the Exit button to GND.  
- Door Contact Sensor Connection  
1. Connect one line of the door contact sensor to the yellow with red stripes.  
2. Connect the other line of the door contact sensor to GND.  
- Auxiliary Input Device Connection (AUX 1 (green), AUX 2 (green with white stripes), AUX 3 (green with red  
stripes)  
1. Connect one line of the external input device to AUX 1, AUX 2, or AUX 3.  
2. Connect the other line of the external input device to GND(-).  
12_ Installation and External Connection  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Output Connection  
Connect the 10-pin and 7-pin connectors of the controller as follows:  
EXIT  
EXIT  
BUTTON  
CONTACT  
DOOR  
CONTACT  
AUX IN#1  
CHIME  
+12V  
GND  
GND  
DOOR  
RELAY  
COM  
ALARM  
RELAY  
COM  
PIR SENSOR  
DOOR  
RELAY  
NO  
ALARM  
RELAY  
NO  
Anode  
Cathode  
CHIME BELL  
1N4004~1N4007 or equiv.  
+12V  
GND  
DC 12V  
POWER  
SUPPLY  
DOOR  
LOCK  
SIREN  
- Door open (POWER FAIL SAFE) when the power is disconnected from the door lock (Door Relay)  
1. Connect the relay COM line (gray with red stripes for locking the door) to DC +12V.  
2. Connect the relay NC line (blue with white stripes for locking the door) to the plus(+) line of the door lock.  
3. Connect the minus (-) line of the door lock to GND (-).  
- Door close (POWER FAIL SECURE) when the power is disconnected from the door lock (Door Relay)  
1. Connect the relay COM line (gray with red stripes for locking the door) to DC +12V.  
2. Connect the relay NO line (white with red stripes for locking the door) to the plus (+) line of the door lock.  
3. Connect the minus (-) line of the door lock to GND (-).  
- Alarm Connection (Alarm Relay)  
1. Connect the relay COM (white for the alarm device) to DC +12V.  
2. Connect the relay NO line (purple for the alarm device) to the plus (+) line of the alarm device.  
3. Connect the minus (-) line of the alarm device to GND (-).  
- Chime Bell Connection (the chime bell operated by TTL-level signal must be installed in advance.)  
1. Connect the chime bell line (brown with white stripes) of the controller to DC +5V.  
2. Connect the GND line of the power supply unit to GND (-) of the chime bell.  
ESC  
3. Press  
to a0ctivate EthNeT chime bell.  
English _ 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
installation and external connection  
EXTERNAL READER CONNECTION  
Wiegand DATA0(Pink)  
Wiegand DATA0(Sky blue)  
GND  
(+)  
(-)  
검은색-  
빨간색+  
DC+12V  
- Proximity Reader Connection  
1. Connect the DC 12V(+) of the power supply unit to the plus (+) line of the reader.  
2. Connect the GND(-) line of the power supply unit to the minus (-) line of the reader.  
3. Connect the Wiegand data input line 0 of the proximity reader to the purple line.  
4. Connect the Wiegand data input line 1 of the proximity reader to the sky blue line.  
For a list of compliant readers (external readers), see the followings:  
- Standard 26bit Wiegand format proximity reader  
14_ Installation and External Connection  
Download from Www.Somanuals.com. All Manuals Search And Download.  
initialization  
BASIC OPERATIONS  
Initial Status  
While the product is working normally, the orange LED indicator blinks every one second.  
Predefined Operation for a Registered Card  
When reading a registered card, it opens the door with the melody.  
Exit Button Operation  
If you press the Exit button, the door will be opened.  
Predefined Operation for an Unregistered Card  
When reading an unregistered card, it produces an alarm with the melody for two seconds.  
You can specify the use of the alarm and change the operation time.  
Secure Mode Operation  
The person who exits the last can set the secure mode using the keypad.  
ENT  
9
Set Secure mode: Press the  
button twice and press  
.
Release secure mode: Present and authenticate a registered card or the Master Card to the reader. You can use  
the keypad to specify the delayed start time for the Secure mode. (Refer to the delayed start time in Secure mode  
on page 28.)  
For effective security purposes, you can set to activate the sensors (via auxiliary input ports) only in Secure mode.  
M
Duress Alarm  
ENT  
If you are forced to open the door under a robber’s control, enter the Duress password and press  
number of your registered card (or PIN). (See page 24.)  
with the  
How to use the chime bell  
ESC  
When you have connected and set the chime bell, press  
to ring the chime bell. (See page 34.)  
English _ 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
initialization  
WIEGAND OUTPUT SETUP  
You can transfer data of the card read by SSA-S2000 in the 26-bit Wiegand output format.  
Enabling this function will disable the TTL output and the chime bell sound.  
1. To enable the 26-bit Wiegand output, you must manipulate the switch panel (SW1 and SW2) on the rear of the  
product.  
2. See the table below to make adjustment as needed.  
Changing Output  
SW1 #1  
ON  
SW1 #2  
OFF  
SW2 #1  
ON  
SW2 #2  
OFF  
Orange line with white stripes  
TTL Output  
Brown line with white stripes  
Chime Bell Output  
OFF  
ON  
OFF  
ON  
Wiegand Data0  
Wiegand Data1  
In the 26-bit Wiegand output mode, you can not initialize the product by short-circuiting cables.  
J
INITIALIZATION  
If you have the Master Card registered, you can use it to initialize the device.  
1. Present the Master Card to the device.  
ENT  
9
2. Press the  
button twice and press  
.
3. The system will restore the factory default settings with all LED indicators  
blinking.  
Initializing the system will lose all data.  
M
If the product works abnormally, use initialization to restore the default settings.  
16_ Initialization  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FORCED INITIALIZATION WITH EXTERNAL LINE  
1. Turn off the product, shortcircuit between the green line and  
the orange line with white stripes, and turn it back on.  
12V  
GND  
2. When the initialization is completed, 3 LED indicators are  
Green  
blinking with a beep.  
Orange with white stripes  
Connect  
(Short-  
circuit)  
3. Restore the connection of the two lines back to their original  
state.  
HARDWARE FORCIBLE INITIALIZATION  
This is to initialize the product forcibly by disassembling it.  
Use this method only if you have lost the Master Card or the password, or if the forcible initialization with the external line  
failed.  
1. Turn off the product and detach it from the installation site, then loosen the screw (x4) on each corner to  
disassemble it as shown.  
Connect  
2. Apply power to the product and short-circuit the jumper for  
(Short-circuit)  
one second as shown.  
3. When the initialization is completed, 3 LED indicators are  
blinking.  
4. Turn off the product and restore it to the original  
installation state.  
English _ 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
reader mode setup  
- You can specify the operation mode for the device.  
- Once a mode is specified, it will not switch until you perform the initialization.  
- You must keep the Master Card in safe for later use as it is required for your change to the device settings.  
- If progression is halted for more than one minute during any of the following processes, the operation mode of the reader  
will return to the previous state.  
READER MODE SETUP (RF ONLY)  
No Master Card or Master PIN is ever registered.  
If you remember the Master Card or the Master PIN was registered, initialize the product and try again.  
1. When you turn on the product, all of the 3 LED indicators will flash with a  
beep.  
No flashing of the 3 indicators denotes that the reader mode is already  
specified.  
ENT  
0
1
2. Press Button  
and Button  
in sequence and press  
.
When the mode is specified, only the green LED indicator flashes.  
3. Present a card that you want to register as the Master Card to the device.  
When the Master Card is registered, only the red LED indicator flashes.  
4. Present cards to register with the device one after another, and the device  
will register them with a beep. If you don’t want to register the cards right  
now, simply jump to Step 5 above without through Step 4 above.  
5. Present the registered Master Card to the product once again.  
6. The device enters Standby mode with only the orange LED indicator flashing.  
Î
Î
Î
18_ Reader Mode Setup  
Download from Www.Somanuals.com. All Manuals Search And Download.  
READER MODE SETUP (RF + P/W)  
No Master Card or Master PIN is ever registered.  
If you remember the Master Card or the Master PIN was registered, initialize the product and try again.  
1. When you turn on the product, all of the 3 LED indicators will flash with a beep.  
No flashing of the 3 indicators denotes that the reader mode is already  
specified.  
ENT  
2
0
2. Press Button  
and Button  
in sequence and press  
.
3. Present a card that you want to register as the Master Card to the device.  
When the Master Card is registered, only the red LED indicator flashes.  
ENT  
4. Present a card to the device, enter the 4-6 digit password and press  
.
If you don’t want to register the cards right now, simply jump to Step 5 above  
without through Step 4 above.  
5. Present the registered Master Card to the product once again.  
6. The device enters Standby mode with only the orange LED indicator flashing.  
Î
Î
Î
READER MODE SETUP (PIN ONLY)  
No Master Card or Master PIN is ever registered.  
If you remember the Master Card or the Master PIN was registered, initialize the product and try again.  
1. When you turn on the product, all of the 3 LED indicators will flash with a  
beep.  
No flashing of the 3 indicators denotes that the reader mode is already  
specified.  
ENT  
0
3
2. Press Button  
and Button  
in sequence and press  
.
When the mode is specified, only the green LED indicator flashes.  
ENT  
3. Enter the 4-6 digit Master PIN number and press  
.
When the Master PIN is registered, only the red LED indicator flashes.  
4. Enter a PIN number to register (4-6 digits) and press  
Repeat the step above if you want to register PIN numbers with the device in sequence.  
If you don’t want to register the PIN number right now, simply jump to Step 5 above without through Step 4  
above.  
ENT  
5. Enter the 4-6 digit Master PIN number again and press  
.
6. The device enters Standby mode with only the orange LED indicator flashing.  
English _ 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
reader mode setup  
READER MODE SETUP (RF/PIN COMBINATION MODE)  
No Master Card or Master PIN is ever registered.  
If you remember the Master Card or the Master PIN was registered, initialize the product and try again.  
1. When you turn on the product, all of the 3 LED indicators will flash with a  
beep.  
No flashing of the 3 indicators denotes that the reader mode is already  
specified.  
ENT  
0
5
2. Press Button  
and Button  
in sequence and press  
.
3. Present a card that you want to register as the Master Card to the device.  
When the Master Card is registered, only the red LED indicator flashes.  
4. Present cards or PIN numbers (4-6 digits) to register with the device one  
after another, and the device will register them with a beep. If you don’t want  
to register the cards right now, simply jump to Step 5 above without through Step 4 above.  
5. Present the registered Master Card to the product once again.  
6. The device enters Standby mode with only the orange LED indicator flashing.  
or  
Î
Î
ENABLING KEYPAD INPUT FOR THE CARD NUMBER  
Ensure that you must have registered the Master Card.  
1. Present the Master Card to the device.  
ENT  
7
3
2. Press Button  
and Button  
in sequence and press  
.
7
Repeat Step 1 above to release the specified mode, press Button  
and  
ENT  
4
Button  
in sequence, and press  
.
You can set the device to allow you to control the door by entering the 8 digit  
card number using the keypad.  
M
The default is “Keypad Input Disabled”.  
20_ Reader Mode Setup  
Download from Www.Somanuals.com. All Manuals Search And Download.  
user management  
TO REGISTER CARDS IN RF ONLY MODE  
Ensure that you must have registered the Master Card and the device is specified in RF ONLY mode.  
1. Present the Master Card to the device.  
When the mode is specified, only the green LED indicator flashes.  
ENT  
1
1
2. Press Button  
and Button  
in sequence and press  
.
When the device enters Standby, only the red LED indicator flashes.  
3. Present a card to the device, it will be registered with a beep.  
Repeat this step if you want to register multiple cards.  
4. Present the Master card to the device again, and the device will switch to normal  
mode. If no input is made for 20 seconds, the device will switch to normal mode.  
Î
Î
REGISTERING CARDS IN A COMBINATION OF RF AND P/W MODES  
Ensure that you must have registered the Master Card and the device is specified in RF + P/W mode.  
1. Present the Master Card to the device.  
When the mode is specified, only the green LED indicator flashes.  
ENT  
1
2
2. Press Button  
and Button  
in sequence and press  
.
When the device enters Standby, only the red LED indicator flashes.  
ENT  
3. Present a card to the device, enter the 4-6 digit password and press  
.
Repeat this step if you want to register multiple cards.  
4. Present the Master card to the device again, and the device will switch to normal  
mode.  
If no input is made for 20 seconds, the device will switch to normal mode.  
Î
Î
Î
English _ 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
user management  
TO REGISTER CARDS IN PIN MODE  
Ensure that you must have registered the Master Card and the device is specified in PIN mode.  
ENT  
1. Enter the Master PIN number and press  
.
When the mode is specified, only the green LED indicator flashes.  
ENT  
1
3
2. Press Button  
and Button  
in sequence and press  
.
When the mode is specified, only the green LED indicator flashes.  
ENT  
3. If you enter a user number (4-6 digits) to register and press  
number will be registered with a beep.  
, the PIN  
Repeat this step if you want to register multiple PIN numbers.  
4. Present the Master PIN number to the device again, and the device will switch  
to normal mode.  
<Master PIN>  
If no input is made for 20 seconds, the device will switch to normal mode.  
Î
Î
<User Number>  
<User Number>  
<Master PIN>  
REGISTERING CARDS IN RF CARD / PIN COMBINATION MODE  
Ensure that you must have registered the Master Card and the device is specified in RF Card / PIN combination mode.  
1. Present the Master Card to the device.  
When the mode is specified, only the green LED indicator flashes.  
ENT  
5
1
2. Press Button  
and Button  
in sequence and press  
.
When the device enters Standby, only the red LED indicator flashes.  
3. Present cards or PIN numbers (4-6 digits) to register with the device one after  
another, and the device will register them with a beep.  
Repeat this step if you want to register multiple cards or PIN numbers.  
4. Present the Master PIN number to the device again, and the device will switch to normal mode.  
If no input is made for 20 seconds, the device will switch to normal mode.  
or  
Î
Î
The door may be accessed in two ways: using the card or the PIN number.  
M
22_ User Management  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TO DELETE A REGISTERED CARD OR PIN NUMBER  
Ensure that you must have registered the Master Card or the Master PIN number and the device is specified in a certain  
mode. This is applicable in all modes.  
1. Enter the Master Card or Master PIN.  
When the mode is specified, only the green LED indicator flashes.  
ENT  
1
4
2. Press Button  
and Button  
in sequence and press  
.
When the device enters Standby, only the red LED indicator flashes.  
3. Present a card or PIN number to delete.  
Repeat this step if you want to register multiple cards or PIN numbers.  
4. Present the Master card to the device again, and the device will switch to normal mode.  
If no input is made for 20 seconds, the device will switch to normal mode.  
or  
Î
Î
English _ 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
basic setup  
DURESS ALARM  
If you are forced to open the door under the control of a criminal such as a robber, enter the predefined password with the  
number of your registered card (or PIN), which outputs the emergency TTL signal.  
1. Present the Master Card to the device.  
ENT  
2
9
2. Press Button  
and Button  
in sequence and press  
.
ENT  
3. Enter the two-digit Duress code and press  
.
The default code is set to “00”. However, the number “77” can not be used  
because it is set for the Secure mode.  
TO SPECIFY THE RETRY COUNT FOR AN UNREGISTERED ID  
You can specify the retry count for authentication with an unregistered card or PIN.  
If the retry count exceeds the set limit, the keypad input will be suspended for the next one minute. (You can specify the  
keypad input suspension time in “To specify the keypad input suspension time if the retry count with an unregistered ID  
exceeds the limit” on page 25.)  
1. Present the Master Card to the device.  
ENT  
2
8
2. Press Button  
,
and Button  
in sequence and press ENT.  
ENT  
3. Enter the two-digit retry count and press  
.
You can specify a number from 00 to 99.  
The retry count for an unregistered ID is defaulted to “05”.  
24_ Basic Setup  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TO SPECIFY THE KEYPAD INPUT SUSPENSION TIME IF THE RETRY  
COUNT WITH AN UNREGISTERED ID EXCEEDS THE LIMIT  
1. Present the Master Card to the device.  
ENT  
6
0
2. Press Button  
and Button  
in sequence and press  
.
ENT  
3. Enter the two-digit keypad input suspension time (unit: minute) and press  
.
The default is set to “01”.  
You can specify a time from 01 to 99 minutes.  
You can specify the time of the keypad input suspension (followed by an alarm) if  
an unregistered user keeps trying to open the door for certain times (the code  
number is set to “82”.  
M
TO SPECIFY THE DELAYED START TIME IN SECURE MODE  
1. Present the Master Card to the device.  
ENT  
8
0
2. Press Button  
and Button  
in sequence and press  
.
ENT  
3. Enter the two-digit delayed start time (unit: minute) and press  
.
The default is set to “00”.  
See the table below for your reference.  
M
When the last person set the Secure mode before exiting the office, the external sensors will  
get activated since then.  
Secure Mode  
If the external sensors get activated right after you set the Secure mode, your motion will be  
detected before you can get out of the secure area, which will trigger the alarm. Thus, it is  
recommended to set the Secure mode to get activated after a certain time.  
Delayed Start  
Enter the delayed start time by the minute; the sensor operation in Secure mode must have been specified in  
advance. (Refer to “Alarm Operation Time for Auxiliary Input” on pages 31-32)  
English _ 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
basic setup  
TO SPECIFY THE OPERATION TIME OF THE DOOR CONTACT SENSOR  
The Door Contact sensor detects the opening of the door.  
If the door is forcibly opened by an unregistered user, the Door Contact Sensor will perform the predefined alarm  
operation after the set time. (For setting the alarm operation time, refer to the alarm output for an input error of the  
Door Contact Sensor on page 31.)  
1. Present the Master Card to the device.  
ENT  
ENT  
1
8
2. Press Button  
and Button  
in sequence and press  
.
3. Enter the two-digit operation time (unit: second) and press  
.
The default is set to “00” second, which means the Door Contact Sensor is  
disabled.  
You can specify from 01 to 99.  
TO SPECIFY THE LIMITED TIME FOR THE KEYPAD INPUT  
When it passes a certain time during your setting using the keypad , all your settings will be ignored and return to the initial  
state.  
Specify the delay time between the input of the last key and restoring the previous state.  
1. Present the Master Card to the device.  
ENT  
ENT  
3
8
2. Press Button  
and Button  
in sequence and press  
.
3. Enter the two-digit operation time (unit: second) and press  
.
The default is set to “20” second.  
You can specify from 10 to 99.  
26_ Basic Setup  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TO SPECIFY THE ALARM OUTPUT PORT FOR THE DISMANTLED DEVICE  
Specify the alarm type for the dismantled device. The alarm rings from the dismantlement of the device to the  
authentication of the Master Card or a registered card.  
1. Present the Master Card to the device.  
ENT  
4
8
2. Press Button  
and Button  
in sequence and press  
.
ENT  
3. Provide the alarm output port and press  
.
The default is set to “02” (alarm).  
For the alarm output port settings, refer to the output port table on page 29.  
The alarm for the dismantled device occurs regardless of the operation mode  
of either Normal or Secure so you simply specify the operation port only. (To  
specify the operation port, refer to the operation port settings in the output  
port setting table on page 29.)  
TO OPEN OR CLOSE THE ENTRY DOOR  
Follow the step below If you want to keep the door open regardless of the authentication  
process using the Master Card or PIN.  
1. Present the Master Card to the device.  
ENT  
4
1
2. Press Button  
and Button  
in sequence and press  
.
To release opening the door, repeat Step 1 above, select the  
ENT  
4
2
<
> buttons and press  
.
English _ 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
basic setup  
TO SET OR RELEASE THE QUICK MODE  
The QUICK mode is applicable to RF ONLY mode (01) and PIN ONLY mode (03) and RF/PIN combination mode (05),  
ENT  
which enables you to open the door by simply pressing  
without the need of the PIN number. (This is useful for the  
normal business hours when the door entries and exits occur frequently.)  
1. Present the Master Card to the device.  
ENT  
4
3
2. Press Button  
and Button  
in sequence and press  
.
To release the QUICK mode, repeat Step 1 above, select the  
ENT  
4
4
<
> buttons and press  
.
The default is set to “not used”.  
TO SET OR RELEASE THE TOGGLE MODE FOR THE DOOR RELAY  
In the Toggle mode, the door opens if it is closed or vice versa by presenting a registered card or entering the PIN.  
1. Present the Master Card to the device.  
ENT  
4
5
2. Press Button  
and Button  
in sequence and press  
.
To release the Toggle mode, repeat Step 1 above, select the  
ENT  
4
6
<
> buttons and press  
.
The default is set to “not used”.  
28_ Basic Setup  
Download from Www.Somanuals.com. All Manuals Search And Download.  
I/O time setup  
Output Port Setting Table  
You must specify the port settings using whatever combination of the followings if you want the device to operate in  
Secure mode or normal + Secure mode.  
Port  
Setting Value  
Example  
EX 1)  
Operation mode setting value  
Operate only in Secure mode  
If only the door relay operates in normal and  
Secure modes  
00  
50  
Normal and Secure modes: 50  
Door Relay: +01  
Operate in normal mode and Secure mode  
Operation port setting value  
Output Port Setting Value: 51  
Operate the door relay only  
01  
02  
04  
05  
06  
EX 2)  
If the alarm relay and the TTL output operate in  
Secure mode  
Operate the alarm relay only  
Operate the TTL output only  
Secure Mode: 00  
Alarm Relay, TTL: +06  
Output Port Setting Value: 06  
Operate the door relay and TTL output  
Operate the alarm relay and TTL output  
TO SPECIFY THE OUTPUT TIME IF THE CARD IS AUTHENTICATED  
You can specify the output time if the card ID is authenticated.  
When the card ID is authenticated, the door relay and the TTL output operate for a set time.  
1. Present the Master Card to the device.  
ENT  
2
1
2. Press Button  
and Button  
in sequence and press  
.
ENT  
3. Enter the two-digit door open time and press  
.
ENT  
4. Specify the two-digit TTL output time and press  
.
For instance, if you set the door open time to “03” and TTL to “00”, the  
door relay operates for 3 seconds for an authenticated card ID.  
By default, the door relay operates for “03” seconds while the TTL  
output works for “00” second in normal and Secure modes.  
You can specify from 10 to 99.  
English _ 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
I/O time setup  
TO SPECIFY THE OUTPUT TIME IF THE CARD IS NOT AUTHENTICATED  
You can specify the output time if an unregistered card or PIN number fails in getting authenticated.  
1. Present the Master Card to the device.  
ENT  
2
2. Press Button  
twice and press  
.
3. Refer to the output port table on page 29 and specify a desired output mode.  
If you want the alarm relay alone to operate in normal and Secure modes for  
ENT  
5
2
an unauthenticated card, select the  
.
<
> buttons and press  
ENT  
4. Enter the two-digit door relay output time and press  
.
ENT  
5. Enter the two-digit alarm relay output time and press  
.
ENT  
6. Enter the two-digit TTL output time and press  
.
You can specify a two-digit time from 00 to 99 seconds.  
By default, only the alarm relay operates for “02” seconds in normal and  
Secure modes.  
Other output ports that are not specified for the output mode will not be activated. For instance, if you set the output  
mode to [5][2] and assign the operation time for each output device by following the steps 4, 5, and 6 above, only the  
alarm relay will operate.  
M
TO SPECIFY THE DURESS TTL OUTPUT  
If you enter the Duress code and present a registered card, the TTL output operates. Specify the TTL operation time for  
this purpose. (For the Duress code, refer to Duress Alarm on page 24.)  
1. Present the Master Card to the device.  
ENT  
3
0
2. Press Button  
and Button  
in sequence and press  
.
ENT  
3. Specify the two-digit TTL output time (unit: second) and press  
.
The default is set to “03” second.  
You can specify a time from 00 to 99 seconds.  
30_ I/O Time Setup  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TO SPECIFY THE ALARM OUTPUT FOR AN INPUT ERROR OF THE  
DOOR CONTACT SENSOR  
You can specify the output port and operation time if an error occurs from the Door Contact Sensor.  
You must have specified the operation time of the Door Contact Sensor. (Refer to “To specify the operation time of the  
Door Contact Sensor” on page 26.)  
1. Present the Master Card to the device.  
ENT  
2
4
2. Press Button  
3. Refer to the output port table on page 29 and specify a desired output mode.  
If you want the alarm relay alone to operate in normal and Secure modes  
and Button  
in sequence and press  
.
5
2
in case of an error from the Door contact Sensor, select the  
<
>
ENT  
buttons and press  
.
ENT  
4. Enter the two-digit door relay output time and press  
.
ENT  
5. Enter the two-digit alarm relay output time and press  
.
ENT  
6. Enter the two-digit TTL relay output time and press  
.
You can specify a two-digit time from 00 to 99 seconds.  
By default, all output times are set to “00”.  
Other output ports that are not specified for the output mode will not be activated. For instance, if you set the output  
mode to [5][2] and assign the operation time for each output device by following the steps 4, 5, and 6 above, only the  
alarm relay will operate.  
M
TO SPECIFY THE ALARM OPERATION TIME FOR AUX 1  
1. Present the Master Card to the device.  
ENT  
2
5
2. Press Button  
and Button  
in sequence and press  
.
3. Refer to the output port table on page 29 and specify a desired output mode.  
If you want the alarm relay alone to operate in normal and Secure modes in  
5
2
case of an input through the auxiliary port, select the <  
> buttons  
ENT  
and press  
.
ENT  
4. Enter the two-digit door relay output time and press  
.
ENT  
5. Enter the two-digit alarm relay output time and press  
.
ENT  
6. Enter the two-digit TTL relay output time and press  
.
You can specify a two-digit time from 00 to 99 seconds.  
By default, all output times are set to “00”.  
Other output ports that are not specified for the output mode will not be activated. For instance, if you set the output  
mode to [5][2] and assign the operation time for each output device by following the steps 4, 5, and 6 above, only the  
alarm relay will operate.  
M
English _ 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
I/O time setup  
TO SPECIFY THE ALARM OPERATION TIME FOR AUX 2  
1. Present the Master Card to the device.  
ENT  
2
6
2. Press Button  
and Button  
in sequence and press  
.
3. Refer to the output port table on page 29 and specify a desired output mode.  
If you want the alarm relay alone to operate in normal and Secure modes in  
case of an input through the auxiliary port, select the  
ENT  
5
2
<
> buttons and press  
.
ENT  
4. Enter the two-digit door relay output time and press  
.
ENT  
5. Enter the two-digit alarm relay output time and press  
.
ENT  
6. Enter the two-digit TTL relay output time and press  
.
You can specify a two-digit time from 00 to 99 seconds.  
By default, all output times are set to “00”.  
Other output ports that are not specified for the output mode will not be activated. For instance, if you set the output  
mode to [5][2] and assign the operation time for each output device by following the steps 4, 5, and 6 above, only the  
alarm relay will operate.  
M
TO SPECIFY THE ALARM OPERATION TIME FOR AUX 3  
1. Present the Master Card to the device.  
ENT  
2
7
2. Press Button  
and Button  
in sequence and press  
.
3. Refer to the output port table on page 29 and specify a desired output mode.  
If you want the alarm relay alone to operate in normal and Secure modes  
5
2
in case of an input through the auxiliary port, select the  
<
>
ENT  
buttons and press  
.
ENT  
4. Enter the two-digit door relay output time and press  
.
ENT  
5. Enter the two-digit alarm relay output time and press  
.
ENT  
6. Enter the two-digit TTL relay output time and press  
.
You can specify a two-digit time from 00 to 99 seconds.  
By default, all output times are set to “00”.  
Other output ports that are not specified for the output mode will not be activated. For instance, if you set the output  
mode to [5][2] and assign the operation time for each output device by following the steps 4, 5, and 6 above, only the  
alarm relay will operate.  
M
32_ I/O Time Setup  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TO ACTIVATE OR DEACTIVATE THE DOOR RELAY BY THE DOOR  
CONTACT SENSOR  
You can set the Door Contact Sensor to control the door lock. This is to allow the Door Contact Sensor to control the door  
relay where the sensor keeps the door relay active from the normal opening of the door to its closing.  
This is useful when the door stays open with just one authentication.  
1. Present the Master Card to the device.  
ENT  
4
7
2. Press Button  
and Button  
in sequence and press  
.
To release the control by the Door contact Sensor, repeat Step 1 above,  
ENT  
4
8
select the <  
> buttons and press  
.
The default is set to “disabled”.  
M
English _ 33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
advanced setting  
TO SPECIFY THE TTL OUTPUT OPERATION MODE  
This is to switch the TTL output from LOW (0V) to HIGH (5V) when it is activated.  
1. Present the Master Card to the device.  
ENT  
1
7
2. Press Button  
and Button  
in sequence and press  
.
To release the setting, repeat Step 1 above, select the  
ENT  
2
7
<
> buttons and press  
.
The default is set to “switch from HIGH(5V) to LOW(0V)”.  
M
TO SET THE CHIME BELL FUNCTION  
You can specify the use of the chime bell.  
Use the chime bell in the TTL level (5V) for this purpose.  
The default output time is 5 seconds. For changing the output time, refer to “To specify the chime bell operation time” on  
page 35.  
1. Present the Master Card to the device.  
ENT  
7
2. Press Button  
twice and press  
.
ENT  
7
8
twice and press  
<
> buttons and press  
.
The default is set to “use the chime bell”.  
M
34_ Advanced Setting  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TO SPECIFY THE CHIME BELL OPERATION TIME  
You can specify the chime bell operation time.  
1. Present the Master Card to the device.  
ENT  
3
9
2. Press Button  
and Button  
in sequence and press  
.
ENT  
3. Specify the two-digit operation time (unit: second) and press  
.
The default is set to “05” second.  
You can specify a time from 00 to 99 seconds.  
M
TO SPECIFY THE INPUT MODE FOR AUX 1  
You can specify an operation for the auxiliary port 1 when it switches from LOW (0V) to HIGH (5V).  
1. Present the Master Card to the device.  
ENT  
6
1
2. Press Button  
and Button  
in sequence and press  
.
To release the setting, repeat Step 1 above, select the  
ENT  
6
2
<
> buttons and press  
.
The default is set to “switch from HIGH(5V) to LOW(0V)”.  
M
English _ 35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
advanced setting  
TO SPECIFY THE INPUT MODE FOR AUX 2  
You can specify an operation for the auxiliary port 2 when it switches from LOW (0V) to HIGH (5V).  
1. Present the Master Card to the device.  
ENT  
6
3
2. Press Button  
and Button  
in sequence and press  
.
ENT  
6
4
To release the setting, press the  
<
> buttons and press  
.
The default is set to “switch from HIGH(5V) to LOW(0V)”.  
M
TO SPECIFY THE INPUT MODE FOR AUX 3  
You can specify an operation for the auxiliary port 3 when it switches from LOW (0V) to HIGH (5V).  
1. Present the Master Card to the device.  
ENT  
6
5
2. Press Button  
and Button  
in sequence and press  
.
To release the setting, repeat Step 1 above, select the  
ENT  
6
6
<
> buttons and press  
.
The default is set to “switch from HIGH(5V) to LOW(0V)”.  
M
36_ 고급 설정  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TO SPECIFY THE INPUT MODE FOR THE EXIT BUTTON  
You can specify an operation for the Exit button when it switches from LOW (0V) to HIGH (5V).  
1. Present the Master Card to the device.  
ENT  
6
7
2. Press Button  
and Button  
and Button  
.
ENT  
6
8
To release the setting, press the  
<
> buttons and press  
.
buttons and press The default is set to “switch from HIGH(5V) to LOW(0V)”.  
M
TO SPECIFY THE INPUT MODE FOR THE DOOR CONTACT SENSOR  
You can specify an operation for the Door Contact Sensor when it switches from LOW (0V) to HIGH (5V).  
1. Present the Master Card to the device.  
ENT  
6
9
2. Press Button  
and Button  
in sequence and press  
.
To release the setting, repeat Step 1 above, select the  
ENT  
7
0
<
> buttons and press  
.
The default is set to “switch from HIGH(5V) to LOW(0V)”.  
M
English _ 37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
additional features  
MUTE  
You can mute the keypad tone or melody in normal operation.  
1. Present the Master Card to the device.  
ENT  
5
1
2. Press Button  
and Button  
in sequence and press  
.
To release the setting, repeat Step 1 above, select the  
ENT  
5
2
<
> buttons and press  
.
By default, it is set to “enabled”.  
M
TO SPECIFY THE USE OF THE TAMPER ALARM  
You can maintain the alarm setup in normal operation and release it in case of a service repair requiring the dismantlement  
of the device. You must set the alarm mode when you have installed the device.For the alarm output port settings, refer to  
“To specify the alarm output port for the dismantled device” on page 27.  
1. Present the Master Card to the device.  
ENT  
8
2. Press Button  
twice and press  
.
To release the alarm setting for the dismantled device, repeat Step 1  
ENT  
8
9
above, select the  
<
> buttons and press  
.
The default is set to “disabled”.  
M
You can release the alarm for the dismantled device by presenting the Master Card  
or a registered card.  
38_ Additional Features  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TO CHECK THE OUTPUT SPECIFIED FOR A REGISTERED CARD USER  
You can check the output setting that you specified in “To specify the output time if the card is authenticated”. (See page  
29.)  
1. Present the Master Card to the device.  
ENT  
3
1
2. Press Button  
and Button  
in sequence and press  
.
TO CHECK THE OUTPUT SPECIFIED FOR AN UNREGISTERED  
CARD USER  
You can check the output setting that you specified in “To specify the output time if the card is not authenticated”. (See  
page 30.)  
1. Present the Master Card to the device.  
ENT  
3
2
2. Press Button  
and Button  
and Button  
.
English _ 39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
additional features  
TO CHECK THE OUTPUT SPECIFIED FOR THE DOOR CONTACT  
SENSOR ALARM  
You can check the output setting that you specified in “To specify the alarm output for an input error of the Door contact  
Sensor”. (See page 31.)  
1. Present the Master Card to the device.  
ENT  
3
4
2. Press Button  
and Button  
in sequence and press  
.
TO CHECK THE OUTPUT SPECIFIED FOR AUX 1  
You can check the output setting that you specified in “To specify the alarm operation time for AUX 1”. (See page 31.)  
1. Present the Master Card to the device.  
ENT  
3
5
2. Press Button  
and Button  
in sequence and press  
.
40_ Additional Features  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TO CHECK THE OUTPUT SPECIFIED FOR AUX 2  
You can check the output setting that you specified in “To specify the alarm operation time for AUX 2”. (See page 32.)  
1. Present the Master Card to the device.  
ENT  
3
6
2. Press Button  
and Button  
in sequence and press  
.
TO CHECK THE OUTPUT SPECIFIED FOR AUX 3  
You can check the output setting that you specified in “To specify the alarm operation time for AUX 3”. (See page 32.)  
1. Present the Master Card to the device.  
ENT  
3
7
2. Press Button  
and Button  
in sequence and press  
.
English _ 41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
other information  
INITIAL VALUES  
This product operates in the following initial values:  
For changing the settings or registering/deleting the user card, refer to the applicable section in this document.  
1) Entry permitted for a registered card  
- The door control relay operates for 3 seconds.  
- The green LED indicator flashes for 3 seconds.  
2) Entry denied for an unregistered card  
- The alarm relay operates for 2 seconds.  
- The red LED indicator flashes for 2 seconds.  
3) Duress Mode Password : 00  
The TTL output port produces a signal for 3 seconds in Duress mode.  
4) QUICK MODE : Disabled  
5) Chime Bell Output : Enabled  
Chime Bell Operating Time : 0.5 second  
6) Melody Sound : Enabled  
7) Keypad Input Limited Use : 20 seconds  
8) When an input signal is sensed : ‘H’ ‘L’ (common for all inputs)  
9) When a TTL output signal is sensed : ‘H -> L’  
10) Patrol Mode Delay Time : 00 minute  
11) Door Sensor Sensing Time : 00 second  
12) Retry count for an unauthenticated entry : 05 times  
13) Alarm for Dismantled Device : Disabled  
Dismantled device Alarm Output Port : 02 (Alarm Relay)  
14) Toggle Mode : Disabled  
15) Control Lock by the Door Sensor : Disabled  
42_ Additional Features  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FUNCTION CODES  
NO.  
Code Number  
Function Item  
Additional user card registration (RF CARD ONLY MODE)  
11  
12  
13  
14  
15  
21  
22  
24  
25  
26  
27  
29  
30  
31  
32  
34  
35  
36  
37  
39  
41  
42  
43  
44  
45  
46  
47  
48  
1
Additional user card and PIN registration (RF CARD + PIN MODE)  
Additional PIN registration (PIN ONLY MODE)  
Delete a rregistered card or PIN number  
Additional user card or PIN registration (RF/PIN combination mode)  
To specify the output time if the card is authenticated  
To specify the output time if the card is not authenticated  
Set the Door Contact Seensor allarming time  
Set the AUX 1 allarming time  
2
3
4
5
6
7
8
9
Set the AUX 2 allarming time  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
Set the AUX 3 allarming time  
Set the Duress Mode password (2 digits)  
Set the TTL output time in Duress Mode  
To check the output of the registered card user (test on code 21)  
To check the output of the unregistered card user  
To check the output specified for the Door Contact Sensor alarm  
To check the output specified for AUX 1  
To check the output specified for AUX 2  
To check the output specified for AUX 3  
Set the chime bell ringing time  
Set the door open  
Release the door opening  
Set the QUIICK Modde  
Release the QUICK Mode  
Toggle to control the door relay  
Release thhe toggling to control the door relay  
Set to controol the door relay using the Door Contact Sensor  
Release the control of the door relay using the Door Contact Sensor  
English _ 43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
other information  
NO.  
Code Number  
Function Item  
51  
52  
60  
61  
62  
63  
64  
65  
66  
67  
68  
69  
70  
71  
72  
73  
74  
77  
78  
80  
81  
82  
83  
84  
88  
89  
99  
Turn off the sound  
Turn on the sound  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
To specify the keypad input suspension time if the retry count with an unregistered ID exceeds the limit  
Sense if AUUX 1 swittches frrom L to H  
Sense if AUUX 1 swittches frrom H to L  
Sense if AUUX 2 swittches frrom L to H  
Sense if AUUX 2 swittches frrom H to L  
Sense if AUUX 3 swittches frrom L to H  
Sense if AUUX 3 swittches frrom H to L  
Sense if tthe Exit button switches from L to H  
Sense if tthe Exit button switches from H to L  
Sense if the Door Contact Sensor switches from L to H  
Sense if the Door Contact Sensor switches from H to L  
Set the TTL output to H  
Set the TTL output to L  
Keypad input enabled  
Keypad input disabled  
Chime bell enabled  
Chime bell disabled  
Set the sttartinngg delay time for Patrol Mode  
Set the opeeration time for the Door Contact Sensor  
To specify the retry count for an unregistered ID  
Set the llimitation time for the keypad input  
Set the alarm output port for the dismantled device  
Dismantled device alarm enabled  
Dismantled device alarm disabled  
System Initialization (all settings deleted)  
44_ Other Information  
Download from Www.Somanuals.com. All Manuals Search And Download.  
troubleshooting  
TROUBLESHOOTING  
If the product does not work properly, please check the followings before contacting us. If the trouble persists, please  
contact the SAMSUNG Customer Service near you.  
Problem  
Action  
When I turn on the product, it does not  
recognize the card with just the 3 LED  
indicators blinking.  
1) Check if the product is installed properly and works normally.  
- In the initial setup of the product or after it is initialized  
Set the operation mode and register the Master card and user cards as usual  
because the product is in the initial state.  
c SSA—2000 modes available : Mode Number + ENT  
RF Only : 01 + ENT  
RF + P/W : 02 + ENT  
PIN Only : 03 + ENT  
RF or PIN : 05 + ENT  
d Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT)  
e Enter the user card or PIN number and provide the password according to the  
mode  
f Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT)  
For more information about registering the Master Card and the user card,  
refer to the initial setup section in the user manual.  
2) If this happens while the product is operating normally (with the Master Card and  
user card registered)  
Product malfunction  
c Power: OFF ON  
d If the problem persists, perform the initialization process for the next step.  
For more information about initializing the product, refer to the initialization  
section in the user manual.  
3) If the problem persists after you have followed the procedures above, contact a  
designated service center.  
The product just switches to normal  
operation mode while I am registering a  
user in a set mode or configure the  
settings.  
1) If no key input is entered within 20 seconds in a set mode, the product will switch  
to normal operation mode automatically. (normal operation)  
English _ 45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
troubleshooting  
Problem  
Action  
I can not register an additional user card 1) Check if the product is installed properly and works normally.  
(or PIN).  
- In the initial setup of the product or after it is initialized  
Set the operation mode and register the Master card and user cards as usual  
because the product is in the initial state.  
c SSA—2000 modes available : Mode Number + ENT  
RF Only : 01 + ENT  
RF + P/W : 02 + ENT  
PIN Only : 03 + ENT  
RF or PIN : 05 + ENT  
d
Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT)  
e Enter the user card or PIN number and provide the password according to the  
mode  
f
Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT)  
For more information about registering the Master Card and the user card,  
refer to the initial setup section in the user manual.  
2) If this happens when you try to register an additional card in normal operation  
mode  
- Register the user card only as the Master Card is already registered.  
c Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT)  
d Command for an additional card registration according to the operation mode  
RF Only : 11 + ENT  
RF + P/W : 12 + ENT  
PIN Only : 13 + ENT  
RF or PIN : 15 + ENT  
e Enter the user card or PIN number and provide the password according to the  
mode  
f
Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT)  
For more information about registering the user card, refer to the additional user  
registration section in the user manual.  
3) If the problem persists after you have followed the procedures above, contact a  
designated service center.  
46_ Troubleshooting  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Problem  
Action  
The user card (or PIN) is not deleted.  
Check the operation status of the product  
1) Check if the product works properly.  
- If the product operates normally (and you have the Master Card or the PIN number)  
c If you have the card to delete  
Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT)  
Enter the command to delete the user: 14 + ENT  
Enter another card to delete (if you have multiple cards to delete)  
Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT)  
d If you have lost the card to delete. But you know the card number  
Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT)  
Enter the command to enable the keypad input: 73 + ENT  
Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT)  
Enter the command to delete the user: 14 + ENT  
Enter another card to delete and press ENT (if you have multiple cards to delete)  
Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT)  
For more information about deleting the user card, refer to the user deletion section in  
the user manual.  
- If you have lost the Master Card (or PIN)  
c Registering or deleting the user card is not possible without the Master Card  
d Initializing the product  
For more information about initializing the product, refer to the initialization section in the  
user manual.  
2) If the problem persists after you have followed the procedures above, contact a designated  
service center.  
I lost the Master Card and could not  
register or delete the card or change the  
settings.  
1) You must initialize the product if you want to change the device settings without the Master Card  
(or PIN). (Initializing the product will restore all your settings regarding the Master Card and user  
cards to the factory default.)  
c
Initialization using the external cable  
Turn off the product and detach it from the wall.  
Turn off the product and detach it from the wall.  
Turn on the product and check the initial state (LED indicators blink with the increasing bell  
sound)  
Disconnect the two short-circuited lines and turn off the product  
d
Hardware Forcible Initialization (use this only if initializing the product with the external cable is  
not possible)  
Turn off the product and detach it from the wall.  
Loosen the 4 screws on the rear to remove the bezel.  
Turn on the product and connect the initialization jumper switch under the LED.  
Check the initialization state: 3 LED indicators are blinking simultaneously.  
Turn off the product and use the 4 screws to attach it back to the wall.  
e
f
Install and use the product as usual.  
For more information, refer to the initialization section in the user manual.  
-
You must consult with a qualified technician for the removal and initialization process of the  
product.  
2) If the problem persists after you have followed the procedures above, contact a  
designated service center.  
English _ 47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
troubleshooting  
Problem  
Action  
SSA-S2000 can recognize a  
presented RF card but can not  
recognize the RF card number  
using the keypad.  
1) Check if the buzzer sounds when you press a key.  
- If you hear the buzzer sound  
c
Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT)  
d Enter the command to enable the keypad input: 73 + ENT  
e For more information, refer to the section of enabling or disabling the keypad  
input for a card number in the user manual.  
- If you hear the buzzer sound after a certain time  
c The keypad input will be suspended for one minute (default) if you enter  
unregistered numbers in 5 consecutive times (default).  
d To change the retry count for an unauthenticated access  
Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT)  
Enter the command to set the retry count for an unauthenticated access 82 + ENT  
Enter a new retry count: two digits + ENT (ex. 10 + ENT the retry count is 10.)  
For more information, refer to the retry count setting section in the user manual.  
e To change the keypad suspension time  
Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT)  
Enter the command to change the keypad suspension time: 60 + ENT  
Enter a new time: two digits + ENT (ex. 10 + ENT the keypad input will be  
suspended for 10 minutes.)  
For more information, refer to the applicable section for the keypad suspension in the user  
manual.  
- If the buzzer stays inactive  
c Initialize the product.  
Initializing the product will restore all your settings regarding the Master Card  
and user cards to the factory default.  
2) If the problem persists after you have followed the procedures above, contact a  
designated service center.  
The Exit button does not work at  
all.  
1) Check if the Exit button is connected to SSA-S2000 properly.  
- Ensure that the Exit button is of the NO type.  
2) Check if the Exit button works normally.  
-
Check the connection cable between the Exit button and SSA-S2000 for any disconnection or short-  
circuit  
Try to connect the two lines on the Exit button.  
.
-
c If SSA-S2000 responds when you press the Exit button  
Replace the Exit button  it is defective  
d If SSA-S2000 does not respond at all  
Initialize the product  the product malfunctions or is damaged.  
(Initializing will restore all data settings to the default.)  
For more information, refer to the initialization section in the user manual.  
3) If the problem persists after you have followed the procedures above, contact a  
designated service center.  
48_ Troubleshooting  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Problem  
Action  
The external reader can the RF card 1) Check if the external reader is connected to SSA-S2000 properly.  
but the RF card data will not be  
transferred to SSA-S2000 or  
irrelevant data is transferred.  
2) Check if the external reader works normally.  
-
Check the connection cable between the external reader and SSA-S2000 for any  
disconnection or short-circuit  
.
-
Check if there occurs a noise on the connection cable between the external reader and SSA-  
S2000.  
c
If you have to use a measuring device such as an oscilloscope or a multimeter, please  
consult with a qualified technician.  
d
Measure the Wiegand communication cable and check if the exit reader works properly.  
: Check the Wiegand output state of the external reader by referring to the user manual,  
and replace the reader if it shows an abnormal output.  
e
f
If there occurs a noise on the Wiegand communication cable using the measuring device  
:
Reinforce the GND line by using the shield line and space line as additional GND points.  
: Extend the Wiegand communication range along with the stable signal reception using the  
repeater  
For more information, refer to the external reader connection section in the user manual.  
3) If the problem persists after you have followed the procedures above, contact a  
designated service center.  
The door lock does not operate at  
all.  
1) Check if the door lock is connected to SSA-S2000 properly.  
The connection method may differ depending on the type and operation mode (NO, NC) of the  
door lock.  
2) Check the status of the door lock  
-
Check the connection cable between the door lock and SSA-S2000 for any disconnection or  
short-circuit..  
-
Check if the door lock works normally.  
c
If you have to use a measuring device such as an oscilloscope or a multimeter, please  
consult with a qualified technician.  
d
Remove the door lock from SSA-S2000, and check the relay output of SSA-S2000:  
Replace the door lock if the relay output of SSA-S200 shows a normal state.  
e
For more information, refer to the door lock connection section in the user manual.  
2) If the problem persists after you have followed the procedures above, contact a  
designated service center.  
English _ 49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
product specifications  
PRODUCT SPECIFICATIONS  
Item  
SSA-S2000  
User  
512 Users  
Power / Current  
Reader Port  
DC 12V / Max.110mA  
External Reder Port 1ea : 26bit Wiegand for Exit  
30ms  
Reading Time (Card)  
Door Open Time  
Input Port  
00~99 Sec. (Default 3Sec.)  
5ea : Exit Button, Door Sensor, Aux#1, #2, #3  
2ea : 2 Form-C Relay Output (COM, NO, NC) / DC12~18V, Rating Max.2A  
1ea : Chime Bell Output / DC5V, Rating Max.500mA  
1ea : TTL Output / DC5V, Rating Max.20mA  
3 LED Indicators (Red, Green and Orange)  
Piezo Buzzer  
Output Port  
LED Indicator  
Beeper  
Keypad  
12 Key Numeric Keypad with Back Lighting  
-30°C to +50°C  
Operating Temperature  
Operating Humidity  
Color / Material  
10% to 90% relative humidity non-condensing  
Silver with Black/ Polycarbonate  
Dimension (W x H x  
D(mm))  
87.0 x 109.0 x 31.0  
220g  
Weight  
50_ product specifications  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Correct Disposal of This Product (Waste Electrical & Electronic Equipment)  
(Applicable in the European Union and other European countries with separate collection systems)  
This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g.  
charger, headset, USB cable) should not be disposed of with other household waste at the end of their working life. To  
prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate these  
items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources.  
Household users should contact either the retailer where they purchased this product, or their local government office, for  
details of where and how they can take these items for environmentally safe recycling.  
Business users should contact their supplier and check the terms and conditions of the purchase contract.  
This product and its electronic accessories should not be mixed with other commercial wastes for disposal.  
Correct disposal of batteries in this product  
(Applicable in the European Union and other European countries with separate battery return systems.)  
This marking on the battery, manual or packaging indicates that the batteries in this product should not be disposed of  
with other household waste at the end of their working life. Where marked, the chemical symbols Hg, Cd or Pb indicate  
that the battery contains mercury, cadmium or lead above the reference levels in EC Directive 2006/66. If batteries are  
not properly disposed of, these substances can cause harm to human health or the environment.  
To protect natural resources and to promote material reuse, please separate batteries from other types of waste and  
recycle them through your local, free battery return system.  
AB82-02555A  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Quadra Fire Indoor Fireplace QV26E B User Guide
Radio Shack Pager 17 8002 05 User Guide
RBH Sound Portable Speaker AWS 6 User Guide
RCA TV VCR Combo 13V401TV User Guide
Renesas Computer Hardware M16C 62P Group User Guide
Roland Musical Instrument E 09 User Guide
Sakar Digital Camera 92045 User Guide
Sanus Systems TV Mount LAS1A User Guide
Sears Microwave Oven 85951 User Guide
SECO LARM USA Garage Door Opener SD C141S User Guide