SECO LARM USA Power Supply ST UV16 W100Q User Guide

ST-UV24-W50Q  
ST-UV16-W100Q  
ST-UVDA-W100Q  
ST-UVDA-W180Q  
24VAC/50VA  
16VAC/100VA  
24/28VAC/100VA  
24/28VAC/180VA  
Features:  
Shielded windings to reduce  
Electromagnetic Interference (EMI).  
(Model: ST-UV16-W100Q shown)  
Selectable input voltage.  
Selectable output voltage  
(see chart below).  
Technical Specifications:  
Model  
Output Voltage Amperage  
VA  
Input Voltage  
ST-UV24-W50Q  
ST-UV16-W100Q  
24VAC  
16VAC  
24VAC  
28VAC  
24VAC  
28VAC  
2.08  
6.25  
4.16  
3.57  
7.50  
6.43  
50VA  
120VAC or 240VAC 50/60Hz  
100VA 120VAC or 240VAC 50/60Hz  
100VA 120VAC or 240VAC 50/60Hz  
100VA 120VAC or 240VAC 50/60Hz  
180VA 120VAC or 240VAC 50/60Hz  
180VA 120VAC or 240VAC 50/60Hz  
UL recognized.  
ST-UVDA-W100Q  
ST-UVDA-W180Q  
Match the ENFORCER Open-Frame  
Transformers with the ENFORCER  
Series Power Supply/Chargers  
ST-2406-2A 1.5A continuous. 6/12/24 VDC  
ST-2406-3A 2.5A continuous. 6/12/24 VDC  
ST-2406-5A 4.0A continuous. 6/12/24 VDC  
Convert low-voltage AC input power  
to low-voltage DC output power.  
ST-2406-7A 7.0A continuous. 6/12/24 VDC  
Regulated and filtered output voltage.  
Short-circuit protection.  
Thermal protection and compensation.  
Built-in backup battery charger.  
Switches to backup battery automatically  
in case of power loss.  
Fused protection for battery charger.  
2 LEDs to indicate AC power input and  
DC power output status.  
Compatible with lead acid or  
gel-type rechargeable battery.  
Reverse polarity protected.  
Transformer Selection Table:  
Output voltage: ST-2406-2A  
ST-2406-3A  
ST-2406-5A  
ST-UV16-W100Q ST-UVDA-W180Q  
16VAC/100VA 24-28VAC/180VA  
ST-2406-7A  
ST-UV24-W50Q  
24VAC/50VA  
6VDC  
12VDC  
24VDC  
12VAC/20VA  
12VAC/40VA  
ST-UVDA-W100Q ST-UV16-W100Q ST-UVDA-W180Q  
24-28VAC/100VA 16VAC/100VA  
24-28VAC/180VA  
ST-UV24-W50Q ST-UVDA-W100Q ST-UVDA-W180Q  
24VAC/50VA 24-28VAC/100VA 24-28VAC/180VA  
24-28VAC/210VA  
Copyright 2007 SECO-LARM U.S.A., Inc. Allrights reserved.  
The SECO-LARM policy is one of continual development. For that reason, SECO-LARM reserves the right to change prices and specifications without notice. SECO-LARM is not responsible for misprints.  
®
1.949.261.2999 (CA &Int’l) 1.800.662.0800 Fax: 1.949.261.7326  
OpenFrameTransformers_pdf.cdr  
Email: info@seco-larm.com Website: www.seco-larm.com  
16842 Millikan Avenue, Irvine, CA 92606  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Quasar Garage Door Opener EUR511516 User Guide
Ricoh Scanner IS430 User Guide
RIDGID Saw R3202 User Guide
Robotis Automobile Electronics DX 116 User Guide
Rolls Stereo System MP322 User Guide
Russell Hobbs Microwave Oven RHM2009S User Guide
Samsung Camera Lens EXT85NB User Guide
Samsung Home Theater System HT H5200 User Guide
Samsung TV Receiver SBB NT User Guide
SATO All in One Printer GL 4xxe User Guide