SECO LARM USA Power Supply PH A1612 GUQ User Guide

16/32 Channel 1U Rack Mount  
CCTV Power Supply  
Manual  
PH-A3224-GUQ Shown  
16-Channel  
32-Channel  
PTC  
PH-A1612-PUQ  
PH-A3224-PUQ  
Glass Fuse  
PH-A1612-GUQ PH-A3224-GUQ  
Industrial design  
12 Amp at 24VAC  
3 Amps per channel  
Easy cable management  
Dual-color LED status indicators  
For rack mounting, wall  
mounting, and stacking  
Field-selectable 24/28 VAC  
Note: Model number that end with “Q” or that have a round green “Q” sticker signify RoHS-compliant products.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ENFORCER RACKMOUNT POWER SUPPLY  
Parts List:  
Rack mount power supply ...........................................................................................................1x  
Cable management brackets ......................................................................................................2x  
Cable management hooks ...........................................................................................................2x  
M3x6 Cable bracket screws .........................................................................................................4x  
Mounting brackets:  
16-channel models (rack/wall/surface mount) ....................................................................................2x  
32-channel models (wall and surface mount only)...............................................................................4x  
Extra-long rack mount brackets (32-channel models only) ..................................................................2x  
Rubber feet ..................................................................................................................................4x  
Power cord ..................................................................................................................................1x  
Front panel lock tab (Glass Fuse models only) ...................................................................................1x  
Spare fuses (PH-A1612-GUQ only, mounted inside unit, see Installation: Section D).....................................3x  
Spare fuses (PH-A3224-GUQ only, mounted inside unit, see Installation: Section D).....................................6x  
Spare main fuse (Mounted inside unit, see Installation: Section C) ..........................................................1x  
Manual .........................................................................................................................................1x  
Specifications:  
PH-A1612-PUQ PH-A1612-GUQ PH-A3224-PUQ PH-A3224-GUQ  
Fuse type  
Input voltage  
Number of outputs  
PTC1  
Glass  
PTC1  
Glass  
120VAC2  
16  
32  
12A@24VAC max.  
10A@28VAC max.  
24A@24VAC max.  
20A@28VAC max.  
Total supply current  
Max. amps per ch.  
Rack size  
Dimensions  
3A@24VAC max.  
1U 19" (44.5x483 mm)  
13/4"x171/2"x1113/32" (45x445x290 mm)  
Weight  
14-lb 14-oz (6.75kg) 22-lb 10-oz (10.25kg)  
1Positive Temperature Coefficient  
2220VAC also available. Please contact SECO-LARM.  
Installation:  
A. Mounting  
1. Decide on a location to install the unit, away from moisture, high humidity, heat sources, etc.  
2. Make sure there is enough space around the unit so air can flow in and out for cooling  
purposes.  
3. Be sure ventilation holes are not blocked by other equipment, rack housing, walls, etc.  
4. To avoid undesirable operation in either the product or other equipment place the unit at  
least 12” (30cm) from any television monitor or other radiation-producing, radiation-sensitive  
or heat-producing equipment such as heaters, radiators, etc.  
A1. Shelf/table mounting  
1. Units may be stacked one on top of the other, or with other equipment.  
2. Make sure the rubber feet are firmly attached to the bottom of the unit as shown in Figure 10  
in the Overview section on page 7, and that no ventilation holes are blocked.  
SECO-LARM U.S.A., Inc.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
ENFORCER RACKMOUNT POWER SUPPLY  
A2. Wall mounting (For 32-channel, see A4)  
Figure 1  
Middle mounting point  
Bracket facing down  
1. Remove the mounting screws from the middle  
mounting points as shown in Figure 1.  
2. Screw the left and right mounting brackets on,  
facing downward as shown in Figure 1.  
3. Make sure no ventilation holes are blocked  
when the unit is in place.  
Mounting bracket  
4. Use screws or bolts (not included) to mount the unit in the desired location.  
Note: Make sure that the screws/bolts and mounting surface can support the weight of the unit.  
A3. Rack mounting (For 32-channel, see A4)  
1. Forward facing installation (for easy view of LED indicators):  
a. Remove the mounting screws from the mounting points at the front of the unit.  
b. Screw the mounting brackets onto the front of the unit as shown in Figure 2 or Figure 10.  
2. Backward facing installation (for easy access to terminal blocks and ON/OFF switch):  
a. Remove the mounting screws from the mounting points at the back of the unit.  
b. Screw the mounting brackets onto the back of the unit as shown in Figure 2 or Figure 10.  
3. Find an appropriate unused 1U space in the equipment rack and screw the unit in place.  
4. Leave at least 0.5U above and below the unit for ventilation.  
Note: No rear support rails are needed. The unit can be fully supported using the mounting  
brackets provided.  
Figure 2  
Power supply mounted facing backward  
Equipment rack vertical supports  
Mounting screws (not included)  
Mounting brackets mounted front/back  
Power supply mounted facing forward  
A4. 32-Channel model  
Front mounting point  
Rear mounting point  
1. Wall mounting:  
a. 32-channel models have 4 wall mounting  
brackets, one for each corner.  
b. Attach the brackets, facing downward, at  
the mounting points on the sides of the  
unit as in Figure 3 on the right.  
Figure 3  
2. Rack mounting: (Caution: Do not use the  
Front or rear  
mounting point  
Extra long mounting bracket  
wall-mounting brackets for rack mounting)  
a. Mount with the 2 extra-long brackets as  
shown in Figure 4 on the right.  
b. Attach each bracket at both the middle  
and either front or rear mounting points.  
Middle mounting point  
Figure 4  
4
SECO-LARM U.S.A., Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ENFORCER RACKMOUNT POWER SUPPLY  
B. Wiring  
1. Unplug terminal blocks from their sockets for easy installation.  
2. Connect equipment power input cables to the screw terminals side by side in N/P pairs.  
3. Screw the terminals closed. Once done, reinsert the terminal block back into its slot.  
4. Select channel voltage for each terminal block with the switches on the back of the unit.  
5. For each group of channels, select either 24VAC or 28VAC. Switch unused channels to OFF.  
Tech Tip: Group cameras with similar power-cable lengths on the same terminal block and set  
the 24/28 VAC switch to compensate for voltage drops. Test voltage after changing settings.  
Caution: Do not set 28VAC unless voltage drops under 21.5VAC to avoid camera  
damage, etc.  
6. Connect the unit’s power cord to a 120V outlet and switch on the unit.  
7. Front-panel LEDs for channels set to 24 or 28 VAC should glow blue to show output is on.  
8. Test the output at the camera end of each power cable to be sure voltage is correct.  
Caution: Always test output voltage before connecting cameras or other equipment.  
9. For cable management, see page 6. For example applications, see page 7.  
C. Replacing the Main Fuse  
Caution: Replace only with same  
Figure 5  
fuse type and rating.  
1. Find the main fuse at the back of  
Fuse holder  
the unit, between the power cord  
socket and the ON/OFF switch, as  
show in Figure 5 on the right.  
Lever fuse holder  
2. To check or replace the fuse, first power the unit and remove the power cord.  
3. Use a flat-head screwdriver to gently lever the fuse holder out at the place shown in Figure 5.  
Be careful not to damage the soft plastic fuse holder with the screwdriver.  
Tech Tip: There is a spare fuse in the top of the fuse holderuse the old fuse to push it out.  
D. Replacing the Channel Fuses (Glass Fuse Models Only)  
Note: PTC fuses automatically resets when current overload is fixed or removed.  
1. Check if the front panel lock tab has been installed.  
2. If so, remove it following the instructions in the section Using the Front Panel Lock Tab below.  
3. Press on the front panel at the place marked “Push” on the upper middle of the panel.  
4. The panel will click open and swing downward.  
5. Each unit is equipped with spare fuses: 3 for 16-channel models; 6 for 32-channel models.  
6. The spares are found in white fuse holders mounted conveniently on the circuit board.  
Caution: Use caution when replacing fuses in order to avoid shocks or shorts.  
E. Using the Front Panel Lock Tab (Glass Fuse Models Only)  
1. Use the front panel lock tab when greater safety or security is needed.  
2. The lock tab prevents the front panel from being opened accidentally or by unauthorized persons.  
SECO-LARM U.S.A., Inc.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
ENFORCER RACKMOUNT POWER SUPPLY  
E1. Locking Tab, front position  
Figure 6  
1. Install the front panel lock tab  
using the screw from the power  
supply front mounting point as  
shown in Figure 6 to the right.  
Front panel  
Mounting bracket  
Front panel lock tab  
Rack mount screw  
3
3
2. To open: Loosen the screw and  
slide the lock tab toward the right  
to let the front panel open.  
3. To close: Slide the lock tab toward the left over the front panel and tighten the screw.  
Note: When loosening the rack mount screw, it may be necessary to support the rear of the unit.  
E2. Locking tab, side positions  
Figure 7  
1. Install the front panel lock tab  
using the screw from the power  
supply front mounting point as  
shown in Figure 7 on the right.  
Front panel  
Mounting screw  
31  
32  
Front panel lock tab  
Front right mounting point  
2. To open: Loosen the screw  
and rotate the lock tab upward  
to let the front panel open.  
3. To close: Rotate the lock tab downward so that it covers the front panel and tighten the screw.  
Tech Tip: If the front panel lock tab falls off while opening, replace it starting with the tab  
pointing up, and turn it down over the front panel.  
F. Cable Management  
1. There are two cable management options included with the product:  
a. Cable management “G” brackets (x2). Screw the brackets onto any of the three mounting  
points on the rear of the unit with the included M3x6 screws. Mount the brackets open end  
at the top, as shown in Figure 8 below or Figure 11 on page 7.  
b. Cable management hooks (x2). Press the white plastic hooks into any of the three mounting  
holes on the rear of the unit as shown in Figure 8 below or Figure 11 on page 7.  
Note: Cable management hooks, once inserted, cannot be removed.  
2. Mount the brackets and route power cables in a way that best suits your installation. Be sure to  
leave slack in the cable to ease future maintenance. Use cable ties to reduce cable tension.  
See example in Figure 8 below.  
Cable management hook  
Cable management bracket  
Figure 8  
Use cable ties to secure cables  
to cable management bracket  
Three mounting points  
marked A, B and C  
To cameras  
6
SECO-LARM U.S.A., Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ENFORCER RACKMOUNT POWER SUPPLY  
Sample Application:  
Figure 9  
DC Cameras, Accessories, etc.  
Rack Mount Power Supply  
Use ENFORCER  
Voltage Converters  
to supply your DC  
equipment  
ST-LA110-TTQ  
ENFORCER Voltage Convertor  
Overview:  
Figure 10  
A: Front mounting point  
Mounting brackets  
Power supply front panel  
B: Center mounting point  
Rubber foot & mounting point  
Channel indicator LEDs  
Figure 11  
Power supply rear panel  
Main fuse socket  
Cable management hook  
Terminal blocks  
Cable management bracket  
Power cord socket  
Main power switch  
24VAC/28VAC/OFF switches  
SECO-LARM U.S.A., Inc.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
ENFORCER RACKMOUNT POWER SUPPLY  
Troubleshooting:  
Power does not turn on  
Check front panel LEDs and rear main fuse.  
Ensure the power cord is firmly in its socket.  
The unit may be overheating. Check for heat  
sources nearby and ensure ventilation holes are  
free from obstruction.  
Power cycles on and off  
Voltage drop is large  
Use 18 gauge or thicker wire.  
The camera case is hot  
Check that the correct power is being supplied.  
Also Available:  
Rack Mount Active  
Balun Hub  
12VDC Tester with  
Continuity  
Passive VPD Balun  
1.0 Amp Voltage  
Converter  
EVT-AH16-VT2Q  
Cut cost and complexity  
by sending CCTV signals  
over Cat5e/6 cables up to  
8,000ft (2.4km).  
ST-BT02Q  
EVT-PB1-31RQ  
Transmit video, power,  
and data signals over a  
single Cat5e/6 cable up  
to 2,000’ (610m).  
ST-LA110-TTQ  
Perform 6 different tests  
including voltage drop,  
voltage with load,  
polarity, and continuity  
(LED only).  
Converts 8~30 VAC/VDC  
to a regulated 5/12/24  
VDC output (adjustable).  
CAUTION: To reduce the risk of electric shock, do  
not open the product case. There are no user  
serviceable parts inside. Refer servicing to qualified  
service personnel.  
Glass fuse models only: During replacement of  
fuses, access fuses via unit front panel only. Use  
caution when working with live electronic  
equipment.  
WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used in normal  
service for a period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is  
limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM.  
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect,  
repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines  
that such equipment is not operating properly as a result of causes other than defects in material and workmanship. The  
sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at  
SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential  
personal or property damages of any kind to the purchaser or anyone else.  
NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the  
SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right  
to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.  
Copyright © 2010 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole  
or in part, without the written permission of SECO-LARM.  
SECO-LARM® U.S.A., Inc.  
16842 Millikan Avenue, Irvine, CA 92606  
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326  
PITSW1  
mi-PH-AXXXX-XUQ_0911.docx  
Order Part # 764-504%  
8
SECO-LARM U.S.A., Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Radio Shack Cell Phone CT 503 User Guide
Radio Shack GPS Receiver PLNV430 User Guide
Radio Shack Motorized Toy Car 60 8504 User Guide
Reebok Fitness Home Gym RBEX29761 User Guide
Russell Hobbs Cooktop RHEH1 User Guide
Samson Musical Toy Instrument MXP144 User Guide
Samsung Projector SP H700 User Guide
Sanus Systems Network Cables ELM302 User Guide
Sanyo Vacuum Cleaner SC X1801 User Guide
Schumacher Battery Charger SC 6500A User Guide