SECO LARM USA Door E 941SA 1200 User Guide

Installation Manual  
®
ENFORCER  
E-941SA-1200  
E-941SA-600  
E-941SA-300  
Electromagnetic Locks  
Also available:  
E-941SA-1K2PD  
1200 lb. maglock  
with status LED  
status sensor &  
delay timer  
E-941DA-1K2P  
Status LED  
Double-Door  
Status LED  
1200 lb. maglock  
with status LEDs &  
status sensors  
HOW THEY WORK  
When power is applied to the magnetic lock, it turns on the unit's powerful built-  
in electromagnet. This electromagnet is attracted to the steel armature plate  
which is mounted on a door, holding the door fast against unauthorized entry.  
When power to the magnetic lock is turned off, the electromagnet releases the  
armature plate, allowing the door to open.  
SPECIFICATIONS  
E-941SA-600  
12VDC/24VDC  
E-941SA-300  
12VDC  
E-941SA-1200  
12VDC/24VDC  
Power  
Magnet Size  
97/8 x 11/16 x 15/8 in.  
(250 x 27 x 42 mm)  
71/4 x 1/2 x 11/2 in.  
(185 x 12 x 38 mm)  
600 lb. (272kg)  
500mA @ 12VDC  
250mA @ 24VDC  
± 10%  
63/4 x 15/16 x 11/4 in.  
(170 x 23 x 32 mm)  
6 x 3/8 x 11/4 in.  
10½ x 15/8 x 25/8 in.  
(268 x 42 x 67 mm)  
71/4 x 5/8 x 23/8 in.  
(185 x 16 x 61 mm)  
1200 lb. (545kg)  
500mA @ 12VDC  
250mA @ 24VDC  
Armature Size  
(152 x 10 x 32 mm)  
300 lb. (136kg)  
315mA @ 12VDC  
Holding Force  
Current Drain  
Voltage Tolerance ± 10%  
± 10%  
Housing  
Aluminum  
Aluminum  
Aluminum  
Temperature  
14° ~ 131°F  
(-10° ~ 55°C)  
11 lb. (5.0kg)  
UL, CUL, CE  
14° ~ 131°F  
14° ~ 131°F  
(-10° ~ 55°C)  
2 lb. 13.5oz. (1.29kg.)  
CE  
(-10° ~ 55°C)  
4 lb. 6oz. (2.0kg.)  
UL, CUL, CE  
Weight  
Certifications  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTROMAGNETIC LOCK Installation Manual  
FIG.  
1
For Inswing Doors  
Filler  
Plate*  
Standard  
Mounting  
*Note: may require more  
than one filler plate.  
"Z"  
Bracket  
"L" Bracket  
(Z/L brackets are not available for E-941SA-300.)  
Steel and  
Steel and  
Rubber  
washers  
(as  
Steel and  
Rubber washers  
(as needed)  
FIG.  
2
Rubber washers  
(as needed)  
Sexnut tube  
Armature  
needed)  
Sexnut  
bolt  
Armature  
Screw  
Sexnut  
bolt  
Armature  
Screw  
Armature Screw  
Armature  
Drill a 8mm  
hole thru door  
Armature  
This side drill  
16mm only  
Drill 12.7mm  
(1/2")  
Drill a 8mm  
hole thru door  
Tap M8 x 1.25 Thread  
HOLLOW METAL DOOR  
SOLID CORE DOOR  
REINFORCED DOOR  
Drill an 8mm hole thru door. From sexnut  
bolt side only, enlarge the 8mm hole to  
16mm.  
Drill an 8mm hole thru door. From sexnut  
bolt side of door, drill 12.7mm (1/2") hole,  
25mm (1") in depth.  
Drill a 6.8mm dia. hole and tap for  
M8 x 1.25 thread.  
(E-941SA-600 &  
E-941SA-1200 only)  
FIG. 3  
Power Cable  
Voltage Selection  
12VDC  
Magnet set for 12VDC  
operation as supplied  
from factory.  
To Magnet  
-
E-941SA-600  
+
ENFORCER  
Control  
Device  
24VDC  
Position a jumper over the  
two middle pins for 24VDC  
operation.  
Power  
Supply  
+
-
R E C R O E N F  
Power Cable  
To Magnet  
E-941SA-1200  
Voltage Selection  
12VDC  
Magnet set for 12VDC  
operation as supplied  
from factory.  
Control  
Device  
+ Power  
INPUT  
POWER  
Supply  
-
24VDC  
Position a jumper over the  
two middle pins for 24VDC  
operation.  
+
-
Important note:  
Check jumper settings before connecting the  
lock to the 24VDC input power. Damage to the  
lock may result from incorrect jumper settings.  
Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTROMAGNETIC LOCK Installation Manual  
TROUBLESHOOTING  
Problem:  
Possible cause: Solutions:  
Door does not lock  
No power  
• Check to make sure the wires are  
securely tightened to the terminal block  
• Check that the power supply is connected  
and operating  
• Make sure the lock switch is wired  
correctly  
Door locks, but can be  
easily forced open  
Poor contact between  
electromagnet and  
armature plate  
• Make sure the electromagnet and  
armature plate are properly aligned  
• Make sure the contact surfaces of the  
electromagnet and armature plate are  
clean and free from rust  
Incorrect voltage  
setting  
• Check the power leads with a meter, and  
make sure 12VDC or 24VDC is present  
Delay in door releasing  
A secondary diode was • The electromagnet is fitted with a metal  
installed across the  
electromagnet  
oxide varistor to prevent interference, so  
do not install a secondary diode  
REGULAR MAINTENANCE  
• Clean the contact surfaces of the electromagnet or armature plate with a soft cloth and non-  
abrasive, non-corrosive cleaner.  
• Apply a light coat of a silicon lubricant to prevent rust. Wipe away the excess.  
• Check that the armature plate is securely attached to the door, yet can pivot slightly around the  
armature screw.  
• Check that the electromagnet is securely attached to the door frame.  
UL CERTIFICATION  
E-941SA-600 and E-941SA-1200 electromagnetic locks conform to UL/10B “Fire Tests of Door  
Assemblies” and UL/10C “Positive Pressure Fire Tests of Door Assemblies” for swinging door  
assemblies. They are also classified in accordance with the Uniform Building Code standard 7-2.  
WARRANTY: ENFORCER Electromagnetic Locks are warranted against defects in  
material and workmanship while used in normal service for a period of one (1) year from the  
date of sale to the original customer. Our obligation is limited to the repair or replacement of any  
defective part if the unit is returned, transportation pre-paid, to SECO-LARM.  
NOTICE  
The information and specifications printed in this manual are current at the time of publication.  
However, the SECO-LARM policy is one of continual development and improvement. For this reason,  
SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not  
responsible for misprints or typographical errors.  
Copyright © 2003 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced  
or copied, in whole or in part, without the written permission of SECO-LARM.  
SECO-LARM® U.S.A., Inc.  
16842 Millikan Avenue, Irvine, CA 92606  
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326  
®
E-mail: sales seco-larm.com  
PITGW1  
E-941SAd.pmd  
@
Page 4  
SECO-LARM U.S.A., Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTROMAGNETIC LOCK Installation Manual  
Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Raypak Indoor Furnishings 302B 2342B User Guide
Recoton Advent Speaker System AW811 User Guide
RedMax Trimmer BC2200E User Guide
Ricoh Printer 120LDS User Guide
Ricoh Printer SP 9100DN User Guide
RightWay GPS Receiver RW 355 User Guide
RocketFish MP3 Player Accessories RF MBT30 User Guide
Sanyo Camcorder VPC HD2000 User Guide
Sanyo Camera Accessories RC 3600HV User Guide
Seiko Instruments Computer Monitor G1216B1N000 User Guide