Model
PSI GPM HP
CS1000.22 1000 2.2 1.5
CS1300.22 1300 2.2 2.0
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING
The following warnings must be followed, Failure to follow
these warnings could result in serious personal injury or death!
Never allow children or untrained personnel to operate machinery.
Electrical equipment can cause shock and sparks.
Do not bypass or remove the grounding prong in any electrical plug. Keep electri-
cal plugs, connections and cords out of water and moisture. Refer to instructions
prior to equipment operation. Disconnect from power source before servicing.
Inspect and repair damaged or exposed electrical components prior to use.Never
splice electrical cords on pressure washers. Be sure the electrical service is ade-
quately sized for the equipment.
Exhaust gases contain harmful gases.
Use only in well ventilated areas or vent the exhaust to the outside.
Exhaust gases can cause death or serious injury.
THIS EQUIPMENT MUST BE VENTED.
High Temperature Water.
Wear protective clothing and face shield.
Do not direct water stream toward self or others.
All hoses should be secured in the lines to be cleaned at least 5 feet.
High pressure water can cause death or serious injury.
High pressure fluid can create a high pressure stream or ruptured vessel.
Wear safety face shield.
Relieve pressure before servicing.
Do not modify/repair/rework vessel or change safety relief or pressure setting.
Do not direct stream toward self or others.
Pressurized fluid streams and ruptured
pressure vessels can cause death or serious injury.
Kerosene, Fuel Oil or Gasoline will burn when ignited.
Wear face shield and protective clothing.
Do not expose fuel to flames, sparks or other sources of ignition.
Use in well ventilated area or vent to outside area.
Fire can cause death or serious injury.
Download from Www.Somanuals.com. All Manuals Search And Download.
Initial setup and operation of your new jetter/pressure washer
Inspection
for freight
damage
When you receive your pressure washer, be sure you check for concealed freight damage. Any
damage should be noted with the delivering carrier. If you have any questions related to freight,
call the 800 number listed on the inside front cover of the manual.
Check all oil levels in the pump or engine, if applicable. Failure to check all levels will result in
equipment damage. Most pumps are shipped with oil from the factory and the crankcase is
sealed. You may have to remove a shipping plug and install a dipstick in the pump.
Inspection
of oil levels
Water supply
Your water supply must provide water to the equipment that exceeds the Gallon Per Minute
(GPM) rate of your machine. You can check your GPM by using a five-gallon bucket and a timer.
If your machine is five GPM or less and the bucket fills in less than a minute you have adequate
supply. Some systems are affected by washing machines, livestock watering systems, and flush-
ing of toilets. Be sure the supply is still adequate when these operations are taking place. The
water temperature cannot exceed 145 degrees Fahrenheit. Pressure should not exceed 60 PSI.
Failure to secure adequate water supply will result in pump damage. Do not run pump
dry!
Your water supply should not contain particles larger than 80 microns. Although there are small
filters installed on pressure washers that filter the water, they can only filter poor quality water
for a short period of time before clogging. This will result in damage to the machine. Therefore,
you should insure no sand or scale particles are present in the water supply.
Water quality
Supply hose
Hook a garden hose from the hydrant to the machine. When doing this, be sure to check the
inlet water filter or screen. This hose should be at least 5/8” diameter with a length at least 15
feet. This 15’ length helps isolate the water supply from pulsations from the pump. Many states
require a vacuum break or backflow preventor be installed at the hydrant, before the
garden hose, to insure the water source cannot be contaminated. Be sure to check
local and state regulations upon installation.
Turn on the water supply and open the trigger gun. This will purge all the air from the system.
Look for water leaks and stop any leak found. Leaks can cause erratic pump behavior.
Purge air
A circuit dedicated only to the pressure washer is recommended. This circuit should be installed
Electrical
Supply
Under Load .
by a licensed electrician and checked to supply adequate voltage
Sometimes the dis-
tance from the panel is to long, the wire size is to small or the voltage is initially to low, this will
cause the GFCI or thermal to trip. If the GFCI trips or the thermal overload on the motor trips
consult factory. Plug your cord into the receptacle. DO NOT USE AN EXTENSION
CORD!
Prior to turning on the power switches check the oil level in the pump.
Pump
In drain jetting applications, the hose must be inserted into the drain line at least five
feet before starting water flow. Be sure machine is not powered on before hose is insert-
ed into the drain.
Federal and
State
Regulations
Many areas are governed by state and federal regulations that protect the envi-
ronment and water quality. In operating this equipment you are also to act
responsibly. Be sure to check with the local, state and federal authorities on
compliance issues.
Download from Www.Somanuals.com. All Manuals Search And Download.
During operation
The pressure was set at the factory during the testing procedure; no adjustments to the machine should be required
for operation. During operation, do not leave the machine running for more than two minutes without the
trigger gun being pulled. Although your machine has a by-pass valve on it and may have a thermal relief system,
this pressure build-up can cause extensive pump damage. If machine will not be discharging water for more than
two minutes, shut the machine off.
Accessory operation
Use extreme caution when attaching devices to the discharge of this equipment. Allow
only trained individuals to operate this machinery. The attachments must be rated to
operate within the pressure range of the equipment or injury could occur. Only use
attachments designed, rated, and sized for the equipment by the manufacturer.
Hose and
reels
The discharge hoses and fittings should be inspected before every use. Also inspect the connec-
tions made on the hose reels. Refer to accessories listing and exploded views included for speci-
fications and replacement parts.
Hose sizing
For pressure wash applications, the ideal hose to deliver adequate water flow and pressure at dis-
tances up to 300 feet is a 3/8” ID hose with a minimum burst pressure rating no less than four
times the operating pressure of the equipment. For drain jetting and sewer cleaning, a hose
should be selected for the adequate pressure range and length needed. The diameter of the hose
should be chosen from the chart below for the application requirements.
Hose size
3/8” or 5/16”
1/4”
Pipe size
Typical application
4” to 8” lines
2” to 4” lines
1” to 2” lines
Floor drains, septic lines, and long runs
Kitchen, laundry drains, and clean-outs
Tight bends, bathroom and trap lines
1/8”
-Remember, when selecting a hose, the smaller diameter and longer the hose, the greater the pres-
sure and flow loss will be.
-Do not couple hoses together for drain jetting. The long couplings will get caught in bends in
the drain lines.
Hose size
considera-
tions
-When drain jetting, always attach a shut-off valve, trigger gun, or foot valve directly to the hose
to be inserted in the drain. This ensures safe shut-off of the water flow at the user’s discretion.
In drain jetting applications, the hose must be inserted into the drain line at least five
feet before starting water flow. Be sure machine is not powered on before hose is
inserted into the drain. Be sure machine is shut down before removing the hose from
the drain. Always be sure hose is marked at the point five feet from the nozzle to iden-
tify nozzle position.
Drain and trap
hoses
Drain and trap hoses listed in the accessory sheet are fitted with a twist-fast coupler. Your drain
jetting equipment is shipped with an assortment of twist-fast couplers to make the necessary con-
nections for the drain hose to be installed either on the existing hose, by removing the drain noz-
zle, or by installing it directly to the foot valve included on some models.
The nozzle, or tip, of the machine is used to restrict the discharge water flow to achieve the rated
operating pressure of the equipment. Only use a properly sized nozzle for your equipment. The
nozzle should be inspected before every use for obstructions and nozzle wear. New nozzles can
be selected from the accessory sheet enclosed in the Operator’s Manual folder pocket.
Nozzles
Download from Www.Somanuals.com. All Manuals Search And Download.
Shut-down procedure
Shut-down
1. Turn off the power switch on the pressure washer.
2. Relieve pressure on line by pulling trigger gun.
3. Shut off water supply and disconnect garden hose.
4. Be sure to check for water leaks or oil leaks that should be repaired before the next oper-
ation.
Storage 5. If you are going to store the machine for extended periods of time in cold climates be sure
to anti-freeze the equipment. A 50% anti-freeze solution may be drawn in through the inlet
of the pump using a short remnant of garden hose. This fluid should be run through the
pump. When the fluid is discharged from the pump discharge your machine is winterized. Do
not allow machine to freeze.
Pump
The pump oil should be changed after the first 50 hours of operation. Then change every
year after that for average use. Oil should be changed more frequently for extensive use or
use in dusty areas or areas with high moisture.
Filters
Water filters, hoses, and fittings should be checked prior to every operation for cleanliness,
leaks, and needed repair or replacement.
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
Despite the complexity of your jetter, a number of common complaints stem from relatively simple problems.
With guidance, the user can identify and remedy many common problems.
Always disconnect the power supply before attempting to service any equipment.
Common problems and solutions
Malfunction
Unit runs but no water dis-
charges
Cause
-Water supply not turned on
-Plugged nozzle on discharge
-Shut off valve is malfunctioning
Remedy
-Turn on water supply
-Remove, clean, or replace nozzle
-Remove, repair, or replace valve
Low nozzle pressure
-Plugged spray nozzle
-Inlet screen is plugged
-Insufficient water supply
-Unloader valve stuck open
-Plugged inlet or discharge hose
-Use of additional lengths of hose
-Remove and clean or replace nozzle
-Remove and clean or replace filter
-Secure adequate water supply
-Disassemble and clean, repair, or replace
-Flush or replace hoses
-Reduce discharge hose length
Surging pressure or drop in
pressure
-Partially plugged spray nozzle
-Worn nozzle
-Remove and clean or replace nozzle
-Remove and replace nozzle
-Soap (low pressure tip installed)
-Restricted or leaking inlet hose, filter
-Cavitation (inadequate water supply)
-Worn pump packings
-Fouled inlet or discharge valves
-Broken valve spring
-Remove and install one of the nozzles
-Check inlet hose, filter; clean or replace
-Secure adequate water supply
-Inspect and replace worn packings
-Inspect and clean or replace valves
-Inspect and replace valve spring
-Inspect, repair, or replace unloader
-Worn or restricted unloader valve
Pressure at pump but low dis-
charge pressure
-Restricted discharger
-Check for discharge obstructions in injector,
gun, hose, valve, wand, and unloader.
Chemical injector not working
properly
-Soap nozzle (low pressure tip) not installed
-Injector valve not turned on
-Discharge hose too long
-Install nozzle with large hole
-Turn on injector by turning fitting on injector
-Reduce hose length or reposition injector to
within 40’ of trigger gun
-Clogged injector pick up hose
-Clogged injector
-Remove, clean, and replace
-Disassemble, clean, and reassemble
Water leaks from pump mani-
fold
-Worn plungers or packings
-Inspect and replace
Unloader does not bypass
-All valves fouled
-Inspect, clean or replace
-Unloader valve seat fouled
-Inspect, clean or replace Unloader assly.
Unloader cycles when gun is
shut off
-Leak in trigger or discharge line
-Inspect, repair or replace leaking fittings
Water in crankcase
-High humidity or direct water spray
-Worn seals
-Reduce oil change intervals
-Replace seals
Download from Www.Somanuals.com. All Manuals Search And Download.
Hose 3/16 x 100’
519033H
Reel Asly
526496.6
Coupler fittings
527810 F x F
527715 Mx F
Hose, Leader
509096
525116
Ball Valve
Pump
TT9061EFUI
Thermal Valve
509312
Tip, Laser
LAS18-CS1300.2
LAS18-CS1000.2
Bracket, Reel
526569.1
Valve, Pulse
GEN100315
Wheel 10x 4
524566
Swivel
526493
Handle
510411T.2D
Motor
521350 (1.5hp)
521308.1 (2hp)
Lynch pin
526521
524100
Rubber foot
Switch
526305
510411T.B
Base, Cart
Download from Www.Somanuals.com. All Manuals Search And Download.
EDP #
DESCRIPTION
LIST
HIGH PRESSURE CHEMICAL INJECTOR
The stainless steel construction makes this nozzle suitable for various soaps, sanitizers,
fungicides and chemical cleaning solutions. Nozzle barrel propels a concentrated spray
pattern up to 25-35 feet. Stainless steel construction provides high strength and chemical
resistance. Adjustment knob at nozzle body allows for convenient chemical metering. 30’
of chemical hose and a check valve which prevents reversal of solution back to the chemical
container are standard features. Weighted strainer filters unwanted debris from entering
the chemical stream.
CAT 7314
Use with 3000 [email protected] GPM
$124.60
CAT 7315
CAT 7316
$124.60
$124.60
JETTER ACCESSORIES
TRAP HOSES
519039
519040
519041
1/8” x 25’ TRAP HOSE 3000# MAX
3/16” x 25’ TRAP HOSE 4000# MAX
3/16” x 50’ TRAP HOSE 4000# MAX
$55.00
$75.00
$135.00
REPLACEMENT HOSES FOR JETTERS
3/16” x 100’ HOSE 3000# MAX
3/16” x 200’ HOSE 3000# MAX
5/16” x 100’ HOSE 4000# MAX
5/16” x 200’ HOSE 4000# MAX
519033
$240.00
$475.00
$245.00
$570.00
519033.1
509083.5H
509083.4
REPLACEMENT HOSES FOR TRAILER JETTERS
1/2” x 200’ HOSE 3000# MAX
1/2” x 300’ HOSE 3000# MAX
1/2” x 400’ HOSE 3000# MAX
1/2” X 500’ HOSE 3000# MAX
509089.200
509089.300
509089.400
509089.500
$1675.00
$2475.00
$3325.00
$4150.00
DRAIN NOZZLES FOR JETTERS
Ram
RAM18-MODEL 1/8” F RAM NOZZLE
RAM14-MODEL 1/4” F RAM NOZZLE
LAS18-MODEL 1/8” F LASER NOZZLE
LAS14-MODEL 1/4” F LASER NOZZLE
COR18-MODEL 1/8” F CORNER NOZZLE
COR14-MODEL 1/4” F CORNER NOZZLE
REV18-MODEL 1/8” F REVOLVING NOZZLE
REV14-MODEL 1/4” F REVOLVING NOZZLE
$40.00
$45.00
$40.00
$45.00
$40.00
$45.00
$136.75
$205.13
Corner
DRAIN NOZZLES FOR TRAILER JETTERS
RAM38-MODEL 3/8” F RAM NOZZLE
LAS38-MODEL 3/8” F LASER NOZZLE
COR38-MODEL 3/8” F CORNER NOZZLE
REV38-MODEL 3/8” F REVOLVING NOZZLE
$55.00
$55.00
$55.00
$250.00
Laser
Revolving
200DS3
200DS4
PORTABLE REEL 3/8” x 200’ 3000#/CART/SHUTOFF
PORTABLE REEL 3/8” x 200’ 4000#/CART/SHUTOFF
$1400.00
$1400.00
509859H
509859
HONDA L.P. CONVERSION KIT
VANGUARD L.P. CONVERSION KIT
$492.91
$492.91
PRESSURE WASH ATTACHMENTS
PRESSURE WASH GUN
#4 MULTI-REG TIP
#5 MULTI-REG TIP
#6 MULTI-REG TIP
509374J
542040
542041
542042
$72.39
$34.94
$34.94
$34.94
Download from Www.Somanuals.com. All Manuals Search And Download.
|