RuggedCom Switch RSG2100 User Guide

TM  
RuggedSwitch RSG2100  
19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports  
TM  
eRSTP  
ZPL  
Zero-Packet-Loss™  
eRSTP  
TM  
The RuggedSwitch™ RSG2100 is an industrially hardened,  
fully managed, modular, Ethernet switch specifically designed  
to operate reliably in electrically harsh and climatically  
demanding utility substation and industrial environments.  
The RSG2100's superior ruggedized hardware design  
coupled with the embedded Rugged Operating System  
(ROS™) provides improved system reliability and advanced  
cyber security and networking features making it ideally  
suited for creating secure Ethernet networks for mission-  
critical, real-time, control applications.  
RuggedRated for Reliability in Harsh Environments  
.Immunity to EMI and heavy electrical surges  
.
Zero-Packet-Loss™ Technology  
.
Meets IEEE 1613 Class 2 (electric utility substations)  
Exceeds IEC 61850-3 (electric utility substations)  
Exceeds IEC 61800-3 (variable speed drive systems)  
Exceeds IEC 61000-6-2 (generic industrial)  
Exceeds NEMA TS-2 (traffic control equipment)  
.
.
.
.
.-40 to +85°C operating temperature (no fans)  
.Conformal coated printed circuit boards (optional)  
.18 AWG galvanized steel enclosure  
The RSG2100's modular flexibility offers 10BaseFL /100BaseFX  
/1000BaseX fiber and 10/100/1000BaseTX copper port  
combinations. Optional front or rear mount connectors make the  
RSG2100 highly versatile for any application and can support  
multiple fiber connectors (ST, MTRJ, LC, SC) without loss of port  
density. The RSG2100 is packaged in a rugged galvanized steel  
enclosure with industrial grade DIN, panel, or 19" rack-mount  
mounting options.  
.Hazardous Location Certification: Class 1 Division 2  
TM  
Rugged Operating System (ROS ) Features  
.Simple plug and play operation - automatic learning,  
negotiation, and crossover detection  
.RSTP (802.1w) and Enhanced Rapid Spanning  
Tree (eRSTP™) network fault recovery (<5ms)  
.Quality of Service (802.1p) for real-time traffic  
.VLAN (802.1q) with double tagging and GVRP support  
.Link aggregation (802.3ad)  
Features and Benefits  
.IGMP Snooping for multicast filtering  
Ethernet Ports  
.Port Rate Limiting and Broadcast Storm Limiting  
.Port configuration, status, statistics, mirroring, security  
.Loss of link management on fiber ports  
.up to 3-Gigabit Ethernet ports  
.up to 16-Fast Ethernet ports  
-
copper and/or fiber  
-
copper and/or fiber  
.2 port modules for tremendous flexibility  
.Non-blocking, store and forward switching  
.Supports many types of fiber (Multimode, singlemode,  
bi-directional single strand)  
.Long haul optics allow Gigabit distances up to 70km  
.Multiple connector types (ST, MTRJ, LC, SC)  
.SNTP time synchronization (client and server)  
.Industrial automation features (eg. Modbus)  
Management Tools  
.Web-based, Telnet, CLI management interfaces  
.SNMP v1/v2/v3  
.Remote Monitoring (RMON)  
Cyber Security Features  
.Multi-level user passwords  
.SSH/SSL encryption  
.Enable/disable ports, MAC based port security  
.Port based network access control (802.1x)  
.VLAN (802.1q ) to segregate and secure network traffic  
.Radius centralized password management  
.SNMPv3 encrypted authentication and access security  
.Rich set of diagnostics with logging and alarms  
Universal Power Supply Options  
.Fully integrated, dual-redundant (optional) power supplies  
.Universal high voltage range: 88-300VDC or 85-264VAC  
.Popular low voltage ranges: 24VDC(9-36VDC),  
48VDC (36-72VDC)  
.Screw or pluggable terminal blocks available  
.Terminal blocks for reliable  
maintenance free connections  
.CSA/UL 60950 safety approved  
I
I
S
SRUGGEDCOM  
9001:20000  
9001:2 00  
O
O
to +85°C  
CERTIFIED  
RuggedSwitchTM RSG2100  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
TM  
RuggedSwitch RSG2100  
19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports  
TM  
ROS Features  
A configurable "weighted fair queuing" algorithm  
Cyber Security  
Cyber security is an urgent issue in many industries where  
advanced automation and communications networks play  
a crucial role in mission critical applications and where high  
reliability is of paramount importance. Key ROS™ features that  
address security issues at the local area network level include:  
controls how frames are emptied from the  
queues.  
VLAN (IEEE 802.1q)  
Virtual local area networks (VLAN) allow the segregation  
of a physical network into separate logical networks with  
independent broadcast domains. A measure of security is  
provided since hosts can only access other hosts on the  
same VLAN and traffic storms are isolated. ROS™ supports  
802.1q tagged Ethernet frames and VLAN trunks. Port  
based classification allows legacy devices to be assigned  
to the correct VLAN. GVRP support is also provided to  
simplify the configuration of the switches on the VLAN.  
.Passwords - Multi-level user passwords secures switch  
against unauthorized configuration  
.SSH / SSL - Extends capability of password protection  
to add encryption of passwords and data as they cross  
the network  
.Enable / Disable Ports - Capability to disable ports so that  
traffic can not pass  
.802.1q VLAN - Provides the ability to logically segregate  
traffic between predefined ports on switches  
.MAC Based Port Security - The ability to secure ports on  
a switch so only specific Devices / MAC addresses can  
communicate via that port  
.802.1x Port Based Network Access Control - The ability  
to lock down ports on a switch so that only authorized  
clients can communicate via this port  
Link Aggregation (802.3ad)  
The link aggregation feature provides the ability to aggregate  
several Ethernet ports into one logical link (port trunk) with  
higher bandwidth. This provides an inexpensive way to set up  
a high speed backbone to improve network bandwidth. This  
feature is also known as "port trunking", "port bundling", "port  
teaming", and "ethernet trunk".  
.Radius - Provides centralized password management  
.SNMPv3 - encrypted authentication and access security  
IGMP Snooping  
ROS uses IGMP snooping (Internet Group Management  
Protocol v1&v2) to intelligently forward or filter multicast traffic  
streams (e.g. MPEG video) to or from hosts on the network.  
The ROS™ cyber security features are included to help  
address the various industry specific security standards such  
as NERC CIP, ISA S99, AGA 12, IEC 62443, ISO 17799:2005 This reduces the load on network trunks and prevents  
and PCSRF SPP-ICS.  
packets from being received on hosts that are not involved.  
ROS™ has a very powerful implementation of  
IGMP snooping that:  
Enhanced Rapid Spanning Tree Protocol (eRSTP™)  
RuggedCom eRSTP allows the creation of fault-tolerant ring  
and mesh Ethernet networks that incorporate redundant links  
that are 'pruned' to prevent loops. eRSTP yields worst-case  
.Can be enabled on a per VLAN basis.  
.Detects and filters all multicast streams regardless of  
whether subscribers exist.  
1
fault recovery of 5ms times the 'bridge diameter' and allows  
rings of up to 80 switches. For example, a ring of ten  
switches will have fault recovery times under 50ms. eRSTP  
implements both STP and RSTP to ensure interoperability  
with commercial switches unlike other proprietary 'ring'  
solutions.  
.Supports "router-less" operation by supporting an  
"active" mode.  
.Restores traffic streams immediately after an RSTP  
topology change.  
SNMP (Simple Network Management Protocol)  
SNMP provides a standardized method for network  
management stations the ability to interrogate devices from  
different vendors. SNMP versions supported by ROS™ are  
v1, v2c, and v3. SNMPv3 in particular provides security  
features (such as authentication, privacy, and access control)  
not present in earlier SNMP versions. ROS™ also supports  
numerous standard MIBs (Management Information Base)  
allowing for easy integration with any network management  
system (NMS).  
Quality of Service (IEEE 802.1p)  
Some networking applications such as real-time control  
or VoIP (voice over IP) require predictable arrival times for  
Ethernet frames. Switches can introduce latency in times  
of heavy network traffic due to the internal queues that buffer  
frames and then transmit on a first come first serve basis.  
ROS™ supports 'Class of Service' in accordance with IEEE  
802.1p that allows time critical traffic to jump ahead to the  
front of the queue thus minimizing latency and reducing jitter  
to allow such demanding applications to operate correctly.  
ROS™ allows priority classification by port, tags, MAC  
address, and IP type of service (TOS).  
1
eRSTP fault recovery times may be approximated as follows:  
For 100 Mbps, fault recovery performance is <5ms/hop  
For 1,000 Mbps, fault recovery performance is <5ms/hop + 20ms  
RuggedSwitchTM RSG2100  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
TM  
RuggedSwitch RSG2100  
19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports  
TM  
ROS Features  
SNMP (Simple Network Management Protocol) (cont’d)  
Port Configuration and Status  
A feature of SNMP supported by ROS™ is the ability to  
generate "traps" upon system events. A NMS can record  
traps from multiple devices providing a powerful network  
ROS™ allows individual ports to be 'hard' configured for  
speed, duplex, auto-negotiation, flow control and more. This  
allows proper connection with devices that do not negotiate or  
have unusual settings. Detailed status of ports with alarm and  
SNMP trap on link problems aid greatly in system  
troubleshooting.  
TM  
troubleshooting tool. RuggedVue is RuggedCom's NMS  
that provides graphical visualization of the network and is  
fully integrated with all RuggedCom products.  
SNTP (Simple Network Time Protocol)  
Port Statistics and RMON (Remote Monitoring)  
ROS™ provides continuously updating statistics per port  
that provide both ingress and egress packet and byte  
counters as well as detailed error figures. Also provided  
is full support for the RMON statistics, history, alarms, and  
event groups. RMON allows for very sophisticated data  
collection, analysis and detection of traffic patterns.  
SNTP automatically synchronizes the internal clock of all  
ROS™ devices on the network. This allows for correlation  
of time stamped events for troubleshooting.  
SCADA and Industrial Automation  
ROS™ contains features that optimize network performance  
and simplify switch management based on the unique  
requirements found in SCADA and industrial automation  
applications. Features such as Modbus TCP management for  
retrieval of switch data using the ubiquitous Modbus protocol  
and DHCP Option 82, a Rockwell Automation ODVA  
requirement for IP address assignment based on the location  
of the end device, provide capabilities not found in typical  
"commercial" or "office grade" Ethernet switches.  
Event Logging and Alarms  
ROS™ records all significant events to a non-volatile  
system log allowing forensic troubleshooting. Events  
include link failure and recovery, unauthorized access,  
broadcast storm detection, and self-test diagnostics  
among others. Alarms provide a snapshot of recent  
events that have yet to be acknowledged by the network  
administrator. An external hardware relay is de-energized  
during the presence of critical alarms allowing an  
external controller to react if desired.  
Port Based Network Access Control (802.1x)  
ROS™ supports the IEEE 802.1x standard that defines  
a mechanism for port-based network access control which  
provides a means of authenticating and authorizing  
devices attached to LAN ports.  
HTML Web Browser and Telnet User Interfaces  
ROS™ provides a simple, intuitive user interface for  
configuration and monitoring via a standard graphical  
web browser or via Telnet. All system parameters include  
detailed on-line help to make setup a breeze. ROS™ ,  
presents a common look and feel and standardized  
configuration process allowing easy migration to other  
RuggedCom managed products.  
Port Rate Limiting  
ROS™ supports configurable rate limiting per port to limit  
unicast and multicast traffic. This can be essential to  
managing precious network bandwidth for service providers.  
It also provides edge security for denial of service  
(DOS) attacks.  
Configuration via ASCII Text File  
Broadcast Storm Filtering  
All configuration parameters are stored in an ASCII  
formatted text file that can easily be transferred via TFTP  
or Xmodem. The configuration file can be saved for  
backup purposes and easily manipulated by a text editor.  
The same text file can be downloaded to the switch at  
a later date in order to re-configure or restore  
a previous configuration.  
Broadcast storms wreak havoc on a network and can cause  
attached devices to malfunction. This could be disastrous on  
a network with mission critical equipment. ROS™ limits this  
by filtering broadcast frames with a user-defined threshold.  
Loss of Link Management  
Some intelligent electronic devices (IEDs) have dual fiber  
optic ports with automatic failover to a backup port should the  
primary fail. ROS™ ensures this mechanism works reliably  
under all failure modes by appropriately disabling link signals  
when required. ROS™ also flushes learned MAC addresses  
to ensure the failover occurs quickly.  
Command Line Interface (CLI)  
A command line interface can be used in conjunction  
with remote shell to automate data retrieval, configuration  
updates, and firmware upgrades. A powerful SQL-like  
capability allows expert users the ability to selectively  
retrieve or manipulate any parameters the device  
has to offer.  
Port Mirroring  
ROS™ can be configured to duplicate all traffic on one port  
to a designated mirror port. When combined with a network  
analyzer, this can be a powerful troubleshooting tool.  
RuggedSwitchTM RSG2100  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
TM  
RuggedSwitch RSG2100  
19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports  
EMI and Environmental Type Tests  
IEC 61850-3 EMI TYPE TESTS  
TEST  
Description  
Test Levels  
Severity Levels  
Enclosure Contact  
Enclosure Air  
Enclosure ports  
+/- 8kV  
+/- 15kV  
20 V/m  
4
4
x
IEC 61000-4-2  
IEC 61000-4-3  
ESD  
Radiated RFI  
Signal ports  
+/- 4kV @ 2.5kHz  
+/- 4kV  
x
4
4
4
D.C. Power ports  
A.C. Power ports  
IEC 61000-4-4  
Burst (Fast Transient)  
+/- 4kV  
3
+/- 4kV  
Earth ground ports  
Signal ports  
D.C. Power ports  
A.C. Power ports  
+/- 4kV line-to-earth, +/- 2kV line-to-line  
+/- 2kV line-to-earth, +/- 1kV line-to-line  
+/- 4kV line-to-earth, +/- 2kV line-to-line  
4
3
4
IEC 61000-4-5  
IEC 61000-4-6  
Surge  
Signal ports  
10V  
10V  
10V  
3
3
3
D.C Power ports  
A.C. Power ports  
Induced (Conducted) RFI  
3
10V  
3
Earth ground ports  
Enclosure ports  
IEC 61000-4-8  
IEC 61000-4-29  
Magnetic Field  
40 A/m continuous, 1000 A/m for 1 s  
30% for 0.1s, 60% for 0.1s, 100% for 0.05s  
N/A  
N/A  
D.C. Power ports  
Voltage Dips & Interrupts  
30% for 1 period, 60% for 50 periods  
N/A  
N/A  
A.C. Power ports  
2
IEC 61000-4-11  
IEC 61000-4-12  
100% for 5 periods, 100% for 50 periods  
2.5kV common, 1kV diff. mode@1MHz  
2.5kV common, 1kV diff. mode@1MHz  
2.5kV common, 1kV diff. mode@1MHz  
30V Continuous, 300V for 1s  
30V Continuous, 300V for 1s  
10%  
2kVac (Fail-Safe Relay output)  
2kVac  
2kVac  
5kV (Fail-Safe Relay output)  
5kV  
5kV  
Signal ports  
D.C. Power ports  
A.C. Power ports  
Signal ports  
D.C. Power ports  
D.C. Power ports  
Signal ports  
D.C. Power ports  
A.C. Power ports  
Signal ports  
D.C. Power ports  
A.C. Power ports  
3
3
3
4
4
Damped Oscillatory  
IEC 61000-4-16  
IEC 61000-4-17  
Mains Frequency Voltage  
Ripple on D.C. Power Supply  
3
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
IEC 60255-5  
IEC 60255-5  
Dielectric Strength  
H.V. Impulse  
IEEE 1613 (C37.90.x) EMI IMMUNITY TYPE TESTS  
Test  
Description  
Test Levels  
Severity Levels  
Enclosure Contact  
Enclosure Air  
Enclosure ports  
Signal ports  
D.C. Power ports  
A.C. Power ports  
Earth ground ports3  
Signal ports  
D.C. Power ports  
A.C. Power ports  
Signal ports  
D.C. Power ports  
A.C. Power ports  
Signal ports  
D.C. Power ports  
A.C. Power ports  
+/- 8kV  
+/- 15kV  
35 V/m  
+/- 4kV @ 2.5kHz  
+/- 4kV  
+/- 4kV  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
IEEE C37.90.3  
IEEE C37.90.2  
ESD  
Radiated RFI  
IEEE C37.90.1  
IEEE C37.90.1  
Fast Transient  
Oscillatory  
+/- 4kV  
2.5kV common mode @1MHz  
2.5kV common, 1kV diff. mode@1MHz  
2.5kV common, 1kV diff. mode@1MHz  
5kV (Fail-Safe Relay output)  
5kV  
5kV  
2kVac  
2kVac  
2kVac  
IEEE C37.90  
IEEE C37.90  
H.V. Impulse  
Dielectric Strength  
Environmental Type Tests  
Description  
Test  
IEC 60068-2-1  
IEC 60068-2-2  
Test Levels  
-40°C, 16 Hours  
+85°C, 16 Hours  
Severity Levels  
Cold Temperature  
Dry Heat  
Test Ad  
Test Bd  
N/A  
N/A  
95% (non-condensing), 55°C , 6  
cycles  
IEC 60068-2-30  
Humidity (Damp Heat, Cyclic)  
Test Db  
N/A  
IEC 60255-21-1  
IEC 60255-21-2  
Vibration  
Shock  
Tests Fc  
Tests Ea  
2g @ (10 - 150) Hz  
30g @ 11mS  
Class 2  
Class 2  
Notes:  
1. Only applicable to functional earth connections separated from the safety earth connection.  
2. Class 2 refers to "Measuring relays and protection equipment for which a very high security margin is required or where the vibration levels are very high,  
( e.g. shipboard application and for severe transportation conditions")  
RuggedSwitchTM RSG2100  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
TM  
RuggedSwitch RSG2100  
19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports  
Technical Specifications  
EMI Immunity and Environmental Compliance  
.IEC 61000-6-2 Industrial (Generic)  
Power Supply  
.Power Consumption: 28W Max  
.24VDC: 9-36 VDC, 1.2A  
.IEC 61800-3 Industrial (Variable Speed Drive Systems)  
.IEC 61850-3 Electric Utility Substations  
.IEEE 1613 Electric Utility Substations  
.48VDC: 36-72 VDC, 0.6A  
.HI Voltage AC/DC: 88-300VDC or 85-264VAC  
.NEMA TS 2 Traffic Control Equipment  
Critical Alarm Relay  
.Form-C contact ratings:  
Max Voltage 250VAC,125VDC  
IEEE Compliance  
.802.3-10BaseT  
.802.3u-100BaseTX, 100BaseFX  
.802.3x-Flow Control  
.802.3z-1000BaseLX  
.802.3ab-1000BaseTX  
.802.3ad-Link Aggregation  
.802.1d-MAC Bridges  
.802.1d-Spanning Tree Protocol  
.802.1p-Class of Service  
.802.1q-VLAN Tagging  
Max Current 2A@250VAC, 0.15A @125VDC,  
2A@30VDC  
Physical  
.Height: 4.42cm / 1.74"  
.Width: 46.48cm / 18.3"  
.Depth: 31.5cm / 12.4"  
.Weight: 5.2kg / 11.5 lbs  
.Ingress Protection: IP40 (1mm objects)  
.Enclosure: 18 AWG galvanized steel enclosure  
.Mounting: DIN rail or panel mounted  
.802.1w-Rapid Spanning Tree Protocol  
.802.1x-Port Based Network Access Control  
IETF RFC Compliance  
.RFC768-UDP  
Switch Properties  
.Switching method: Store & Forward  
.Switching latency: 7 us  
.Switching bandwidth: 9.2 Gbps  
.MAC addresses: 8192  
.MAC address table size: 64kbytes  
.Priority Queues: 4  
.RFC783-TFTP  
.RFC791-IP  
.RFC792-ICMP  
.RFC793-TCP  
.RFC826-ARP  
.RFC854-Telnet  
.Frame buffer memory: 2 Mbit  
.VLANs: 4094  
.IGMP multicast groups: 256  
.Port rate limiting  
.No head of line blocking  
.RFC894-IP over Ethernet  
.RFC1112-IGMP v1  
.RFC1519-CIDR  
.RFC1541-DHCP (client)  
.RFC2030-SNTP  
.RFC2068-HTTP  
.RFC2236-IGMP v2  
.RFC2284-EAP  
.RFC2475-Differentiated Services  
.RFC2865-Radius  
.RFC3414-SNMPv3-USM  
.RFC3415-SNMPv3-VACM  
Approvals  
.ISO: Designed and manufactured using a ISO9001: 2000  
certified quality program  
.CE Marking  
.Emissions: FCC Part 15 (Class A),  
EN55022 (CISPR22 Class A)  
.Safety: cCSAus (Compliant with CSA C22.2 No. 60950, UL  
60950, EN60950)  
.Laser Eye Safety (FDA/CDRH): Complies with 21  
CFR Chapter1, Subchapter J.  
IETF SNMP MIBS  
.RFC1493-BRIDGE-MIB  
.RFC1907-SNMPv2-MIB  
.RFC2012-TCP-MIB  
Warranty  
.RFC2013-UDP-MIB  
.5 Years - Applicable to design and manufacturing  
related product defects.  
.RFC2578-SNMPv2-SMI  
.RFC2579-SNMPv2-TC  
.RFC2819-RMON-MIB  
Network Management  
.HTTP graphical web-based  
.SNMP v1, v2c, v3  
.Telnet, VT100  
.Command Line Interface (CLI)  
.RFC2863-IF-MIB  
.draft-ietf-bridge-rstpmib-03-BRIDGE-MIB  
.draft-ietf-bridge-bridgemib-smiv2-03-RSTP-MIB  
.IANAifType-MIB  
RuggedSwitchTM RSG2100  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
TM  
RuggedSwitch RSG2100  
19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports  
Dimensions  
RuggedSwitchTM RSG2100  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
TM  
RuggedSwitch RSG2100  
19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports  
Mounting Options  
Slot 1  
Slot 2  
Slot 3  
Slot 4  
Slot 5  
Slot 6  
Slot 7  
Slot 8  
Slot 9  
Slot 10  
RuggedSwitchTM RSG2100  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
TM  
RuggedSwitch RSG2100  
19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports  
Order Codes  
RSG2100 -______ -______ -____ -____ -____ -____ -____ -____ -____ -____ -____ -____ -____ -_____  
Main  
Mount PS1  
PS2  
S1  
S2  
S3  
S4  
S5  
S6  
S7  
S8  
S9  
S10  
Slot 1  
Slot 2  
Slot 3  
Slot 4  
Slot 5  
Slot 6  
Slot 7  
Slot 8  
Slot 9  
S5: Gigabit Ethernet Modules for slot 5  
Slot 10  
.
XXXX = Empty  
.
CG01 = 2 x 10/100/1000Tx RJ45  
.
FG01 = 2 x 1000SX - Multimode, 850nm, LC, 500m  
Main: Ethernet and Power Connectors  
.
.
FG02 = 2 x 1000LX - Singlemode, 1310nm, SC connectors, 10km  
R = Ethernet on rear; LED panel on front; power connector on rear  
F = Ethernet on front; LED panel on front; power connector on rear  
B = Ethernet on rear; LED panel on top; power connector on rear  
T = Ethernet on front; LED panel on top; power connector on rear  
.
.
FG03 = 2 x 1000LX - Singlemode, 1310nm, LC connectors, 10km  
.
.
FG04 = 2 x 1000LX - Singlemode, 1310nm, SC connectors, 25km  
.
.
FG05 = 2 x 1000LX - Singlemode, 1310nm, LC connectors, 25km  
.
FG50 = 2 x 1000LX SFP - Blank (no optical transceiver)  
.
FG51 = 2 x 1000SX SFP - Multimode, 850nm, LC, 500m  
Mount: Mounting Options  
RM = 19" Rack Mount Kit  
DP = DIN and Panel Mount Kit  
RD = 19" Rack, DIN, and Panel Mount Kit  
00 = No Mounting Option  
.
FG52 = 2 x 1000LX SFP - Singlemode, 1310nm, LC, 10km  
.
.
FG53 = 2 x 1000LX SFP - Singlemode, 1310nm, LC, 25km  
.
.
FG54 = 2 x 1000LX SFP - Singlemode, 1550nm, LC, 70km  
.
.
FG70 = 2 x 1000LX GBIC - Blank (no optical transceiver)  
.
.
FG71 = 2 x 1000LX GBIC - Singlemode, 1310nm, SC, 10km  
.
FG72 = 2 x 1000LX GBIC - Singlemode, 1310nm, SC, 25km  
PS1 and PS2: Power Supply 1 and 2  
.
FG73 = 2 x 1000LX GBIC - Singlemode, 1550nm, SC, 70km  
.
24 = 24VDC (9-36VDC), screw terminal block  
48 = 48VDC (36-72VDC), screw terminal block  
HI = 88-300VDC or 85-264VAC, screw terminal block  
24P = 24VDC (9-36VDC), pluggable terminal block  
48P = 48VDC (36-72VDC), pluggable terminal block  
HIP = 88-300VDC or 85-264VAC, pluggable terminal block  
XX = No Power Supply (PS2 Only)  
.
S6: Gigabit Ethernet Modules for slot 6  
.
.
XXXXX = Empty  
.
.
1CG01 = 1 x 10/100/1000Tx RJ45  
.
.
1FG01 = 1 x 1000SX - Multimode, 850nm, LC, 500m  
.
.
1FG02 = 1 x 1000LX - Singlemode, 1310nm, SC connectors, 10km  
.
.
1FG03 = 1 x 1000LX - Singlemode, 1310nm, LC connectors, 10km  
.
1FG04 = 1 x 1000LX - Singlemode, 1310nm, SC connectors, 25km  
S1, S2, S3, S4, S7, S8, S9 and S10:  
.
1FG05 = 1 x 1000LX - Singlemode, 1310nm, LC connectors, 25km  
Ethernet Modules for Slots 1, 2, 3, 4, 7, 8, 9 and 10  
.
1FG50 = 1 x 1000SX SFP - Blank (no optical transceiver)  
.
XXXX = Empty  
.
1FG51 = 1 x 1000SX SFP - Multimode, 850nm, LC, 500m  
.
TX01 = 2 x 10/100Tx RJ45  
.
1FG52 = 1 x 1000LX SFP - Singlemode, 1310nm, LC,10km  
FL01 = 2 x 10FL - Multimode, 850nm, ST  
FX01 = 2 x 100FX - Multimode, 1300nm, ST  
FX02 = 2 x 100FX - Multimode, 1300nm, SC  
FX11 = 2 x 100FX – Multimode, 1300nm, LC  
FX03 = 2 x 100FX - Multimode, 1300nm, MTRJ  
FX04 = 2 x 100FX - Singlemode, 1310nm, ST, 20km  
FX05 = 2 x 100FX - Singlemode, 1310nm, SC, 20km  
FX06 = 2 x 100FX - Singlemode, 1310nm, LC, 20km  
FX07 = 2 x 100FX - Singlemode, 1310nm, SC, 50km  
FX08 = 2 x 100FX - Singlemode, 1310nm, LC, 50km  
FX09 = 2 x 100FX - Singlemode, 1310nm, SC, 90km  
FX10 = 2 x 100FX - Singlemode, 1310nm, LC, 90km  
.
1FG53 = 1 x 1000LX SFP - Singlemode, 1310nm, LC, 25km  
.
(2)  
.
1FG54 = 1 x 1000LX SFP - Singlemode, 1550nm, LC, 70km  
.
.
1FG70 = 1 x 1000LX GBIC - Blank (no optical transceiver)  
.
.
1FG71 = 1 x 1000LX GBIC - Singlemode, 1310nm, SC, 10km  
.
.
1FG72 = 1 x 1000LX GBIC - Singlemode, 1310nm, SC, 25km  
.
(2)  
.
1FG73 = 1 x 1000LX GBIC - Singlemode, 1550nm, SC, 70km  
.
NOTES:  
.
1 Distance ratings are typical but will depend on type of cabling, number of connectors and splices.  
2 These transceivers have an operating temperature range of -20 °C to +85°C.  
All other transceivers have an operating temperature range of -40°C to +85°C  
.
.
.
.
Example Order Codes:  
RSG2100-R-RM-HI-HI-TX01-TX01-FX01-FX01-FG02-  
XXXXX-FX01-FX01-FX01-FX01  
19” Rack mounted, HI power supply, HI power supply,  
4 10/100 RJ45 Ethernet Ports, 12 100FX (Multi Mode 1350nm  
Fiber) Ethernet ports, 2 1000LX (Gigabit) Ethernet ports,  
with Ethernet ports on the front  
RSG2100-R-RM-24-48-TX01-TX01-XXXX-XXXX-XXXX-  
XXXXX-XXXX-XXXX-XXXX-XXXX  
19” Rack mounted, 24VDC power supply, 48VDC power  
supply, 4 10/100 RJ45 Ethernet Ports, with Ethernet  
ports on the rear  
RSG2100-F-RM-48-48-TX01-TX01-FX01-FX01-XXXX-XXXXX-  
XXXX-XXXX-XXXX-XXXX  
19” Rack mounted, 48VDC power supply, 48VDC, 4 10/100  
RJ45 Ethernet Ports, 4 100FX (Multi Mode 1310nm Fiber)  
Ethernet ports, with Ethernet ports on the front  
Accessories/Options  
82-01-0002 - Conformal Coating  
41-11-0011 - Cable support brackets  
43-10-0007 - Power cable (North America three  
prong connector -> beau)  
RuggedSwitchTM RSG2100  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
TM  
RuggedSwitch RSG2100  
19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports  
RuggedCom Inc.  
30 Whitmore Road  
Woodbridge, Ontario, Canada L4L 7Z4  
Tel: (905) 856-5288 Fax: (905) 856-1995  
Toll Free: (888) 264-0006  
Technical Support Center: (866) 922-7975 or (954) 922-7975  
© 2007 RuggedCom Inc.  
RuggedSwitch is a trademark of RuggedCom Inc.  
Ethernet is a trademark of the Xerox Corporation.  
Patent Pending  
All specifications in this document are subject to change without notice.  
Rev 2-U  
For additional information on our products and  
RuggedSwitchTM RSG2100  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Radio Shack Home Theater System ARH7078 A User Guide
Raypak Water Heater 992BD 2342BD User Guide
RCA CRT Television F25433 User Guide
Renesas Switch M306V2T RPD E User Guide
Roadmaster Car Speaker VSW120 User Guide
Roland Can Opener MV8800WS04 User Guide
Roland Electronic Keyboard HP 2 User Guide
Rose electronic Photo Scanner CTP 8S User Guide
Rotel Stereo Amplifier RSP 985 User Guide
Sears Battery Charger 20071201 User Guide