RuggedBackbone™
RX1501
Hardware Installation Guide
Revision 104 - October 14, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
RuggedBackbone™ RX1501
Table of Contents
FCC Statement And Cautions ................................................................................................... 8
1. Product Overview ................................................................................................................... 9
1.1. Functional Overview .................................................................................................... 9
1.2. Feature Highlights ....................................................................................................... 9
2. RuggedBackbone™ Modules .............................................................................................. 12
2.1. Front Panel ............................................................................................................... 13
2.1.1. Module Status LEDs ...................................................................................... 13
2.2. Line Modules (LM) .................................................................................................... 14
2.2.1. Ethernet - Copper ........................................................................................... 14
2.2.2. Ethernet - Fiber .............................................................................................. 14
2.2.3. SFP Modular .................................................................................................. 15
2.2.4. WAN ............................................................................................................... 15
2.2.5. Serial .............................................................................................................. 15
2.2.6. Cellular Modem .............................................................................................. 15
2.2.7. DDS - Digital Data Services ........................................................................... 16
2.2.8. APE - Appplication Processing Engine .......................................................... 16
2.3. Power Supply ............................................................................................................ 17
3. Installation ............................................................................................................................ 18
3.1. Rack Mounting .......................................................................................................... 18
3.1.1. Rack Mounting Dimensions ............................................................................ 18
3.1.2. Panel and DIN Rail Mounting ......................................................................... 20
3.1.3. Panel and DIN Rail Mounting Dimensions ..................................................... 21
3.2. Power Supply Wiring and Grounding ........................................................................ 22
3.2.1. Connectors for HI and HIP Power Modules ................................................... 22
3.2.3. Chassis Ground Connection .......................................................................... 23
3.2.4. AC Power Supply Wiring Example ................................................................. 23
3.2.5. DC Power Supply Wiring Example ............................................................... 24
3.3. Critical Alarm Wiring ................................................................................................. 24
3.4. Serial Console Port ................................................................................................... 25
3.5. WAN Ports: RJ45 ...................................................................................................... 25
3.6. WAN Ports: BNC ...................................................................................................... 26
3.7. Copper Ethernet Ports .............................................................................................. 26
3.7.1. RJ45 Twisted-Pair Copper Ports .................................................................... 26
3.7.3. Transient Suppression .................................................................................... 27
3.8. Serial Ports: RJ45 ..................................................................................................... 28
3.9. DDS Ports: RJ45 ...................................................................................................... 28
3.10. DDS Rx and Tx LED Indications ............................................................................ 29
3.11. SFP Optics – Installation, removal, and precautions .............................................. 29
3.11.1. Module Insertion – SFP ............................................................................... 30
3.11.2. SFP Module Removal .................................................................................. 30
3.12. Fiber Ethernet Ports ................................................................................................ 31
3.13. Cellular Modems ..................................................................................................... 32
RuggedCom® RuggedBackbone™
3
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
RuggedBackbone™ RX1501
3.14. APE: Application Processing Engine ...................................................................... 35
3.14.1. APE Overview .............................................................................................. 35
3.14.2. Supported Operating Systems ..................................................................... 35
3.14.3. Secondary Network Interface ....................................................................... 36
3.14.4. Installing an Operating System .................................................................... 37
3.14.5. The APE BIOS ............................................................................................. 38
3.14.6. Resetting the Module ................................................................................... 38
3.14.7. LED Indicators .............................................................................................. 38
3.14.8. FAQs ............................................................................................................ 39
4. Technical Specifications ....................................................................................................... 40
4.1. Power Supply Specifications ..................................................................................... 40
4.2. Critical Alarm Relay Specifications ........................................................................... 40
4.3. Copper Ethernet Port Specifications ......................................................................... 40
4.4. Fiber Ethernet Port Specifications ............................................................................ 41
4.4.1. Fast Ethernet (100Mbps) Optical Specifications ............................................. 41
4.4.2. Gigabit Ethernet (1Gbps) Optical Specifications ............................................ 42
4.5. Operating Environment ............................................................................................. 42
4.6. Mechanical Specifications ......................................................................................... 42
5. EMI And Environmental Type Tests .................................................................................... 43
6. Agency Approvals ................................................................................................................ 45
7. Warranty ............................................................................................................................... 46
RuggedCom® RuggedBackbone™
4
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
RuggedBackbone™ RX1501
List of Figures
2.1. RX1501 Chassis Slot Assignment .................................................................................... 12
2.2. Front View - RX1501 ........................................................................................................ 13
2.3. CG01: 2 × 10/100/1000TX RJ45 ...................................................................................... 14
2.4. 6TX01: 6 × 10/100/1000TX RJ45 ..................................................................................... 14
2.5. FX**/FG**: 2 × 100FX/1000SX/1000LX LC ...................................................................... 14
2.6. 4FX**: 4 × 100FC LC ....................................................................................................... 14
2.7. FX03: 2 × 100 FX MTRJ .................................................................................................. 14
2.8. 4FX03: 4 × 100FX MTRJ ................................................................................................. 14
2.9. FX**: 2 × 100FX SC ......................................................................................................... 14
2.10. FX**: 2 × 100FX ST ....................................................................................................... 14
2.11. 10FL: 3 × 10FL ST ......................................................................................................... 14
2.12. FG5*: 2 × 1000LX/1000SX SFP ..................................................................................... 15
2.13. FX5*: 4 × 100FX/100LX/100SX SFP .............................................................................. 15
2.14. 6FX50: 6 × 100FX SFP .................................................................................................. 15
2.15. TC1: 1 × T1/E1 RJ45 ..................................................................................................... 15
2.16. E01: 1 × E1 BNC ........................................................................................................... 15
2.17. TC2: 2 × T1/E1 RJ45 ..................................................................................................... 15
2.18. E02: 2 × E1 BNC ........................................................................................................... 15
2.19. TC4: 4 × T1/E1 RJ45 ..................................................................................................... 15
2.20. 6S01: 6 × Serial RJ45 .................................................................................................... 15
2.21. W11, W21, W32 Cellular Modem ................................................................................... 15
2.22. W12, W22 Cellular Modem ............................................................................................. 15
2.23. D02: 1 × DDS RJ45 ....................................................................................................... 16
2.24. APE 1402 ........................................................................................................................ 16
2.27. Pluggable terminal block power module (HIP module shown) ........................................ 17
3.1. Side View of Mounting Brackets ....................................................................................... 18
3.2. RX1501Rack Mounting Dimensions – Front View ............................................................ 18
3.3. RX1501Rack Mounting Dimensions – Top View .............................................................. 19
3.4. RX1501Rack Mounting Dimensions – Rear View ............................................................. 19
3.5. Installing Panel and DIN Rail Mounting Brackets ............................................................. 20
3.6. DIN Rail Mounting ............................................................................................................ 20
3.7. Panel and DIN Rail Mounting Dimensions ....................................................................... 21
3.8. Screw Terminal Power Connector for HI Power Module .................................................. 22
3.9. Pluggable Phoenix Power Connector for HIP Power Module ........................................... 22
3.10. Screw Terminal Power Connector for 24 and 48 Power Modules .................................. 22
3.12. Chassis Ground Connection ........................................................................................... 23
3.13. Wiring for Single AC Power Supply (HIP module shown) ............................................... 23
3.14. Wiring for Single DC Power Supply (24P or 48P module shown) ................................... 24
3.15. Critical Alarm Relay Connector ....................................................................................... 24
3.16. DB9 Serial Console Port ................................................................................................. 25
3.17. RJ45 T1/E1 Pin Configuration ........................................................................................ 25
3.18. RJ45 T1/E1 Pin Configuration ........................................................................................ 26
3.19. RJ45 Ethernet Pin Configuration .................................................................................... 26
RuggedCom® RuggedBackbone™
5
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
RuggedBackbone™ RX1501
3.20. RJ45 Serial Pin Configuration ......................................................................................... 28
3.21. RJ45 DDS Pin Configuration .......................................................................................... 28
3.22. DDS Module Rx and Tx LED Indicators ......................................................................... 29
3.23. SFP module orientation .................................................................................................. 30
3.24. SFP module insertion ..................................................................................................... 30
3.25. SFP module removal ...................................................................................................... 31
3.26. LC .................................................................................................................................... 31
3.27. MTRJ ............................................................................................................................... 31
3.28. SC ................................................................................................................................... 31
3.29. ST .................................................................................................................................... 31
3.30. Single Port Cellular Modem: Antenna Connections ........................................................ 32
3.31. Dual Port Cellular Modem: Antenna Connections .......................................................... 32
3.33. Cellular Modem Module Assembly: W12 Dual Antenna Modules ................................... 33
3.34. APE Faceplate and Ports ............................................................................................... 35
3.35. APE Chassis Network Connection .................................................................................. 36
RuggedCom® RuggedBackbone™
6
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
RuggedBackbone™ RX1501
List of Tables
2.1. Module Status LED Indications ......................................................................................... 13
3.1. DB9 Serial Console Pinout ............................................................................................... 25
3.2. RJ45 T1/E1 Pin Assignment ............................................................................................. 25
3.3. RJ45 Ethernet Pin Assignment ......................................................................................... 26
3.4. Cabling Categories and 1000Base-TX Compliance .......................................................... 27
3.5. RJ45 RS232/RS485/RS422 Serial Pin Assignment .......................................................... 28
3.6. RJ45 DDS Pin Assignment ............................................................................................... 28
3.7. DDS Rx LED Indications .................................................................................................. 29
3.8. DDS Tx LED Indications ................................................................................................... 29
3.9. Available Fiber Connector Types ...................................................................................... 31
3.10. Cellular Modem Modules ................................................................................................ 32
3.11. HSPA Antenna Requirements ........................................................................................ 33
3.12. APE Specifications .......................................................................................................... 35
3.13. APE Module LED Indicators ........................................................................................... 38
4.1. Power Supply Specifications ............................................................................................. 40
4.2. Form C Contact Relay Specifications ............................................................................... 40
4.3. Copper Ethernet Port Specifications ................................................................................. 40
4.4. Fast Ethernet (100Mbps) Optical Specifications ............................................................... 41
4.5. SFP Fast Ethernet Transceivers ....................................................................................... 41
4.6. Fixed Gigabit Transceivers ............................................................................................... 42
4.7. SFP Gigabit Transceivers ................................................................................................. 42
4.8. Operating Environment ..................................................................................................... 42
4.9. Mechanical Specifications ................................................................................................. 42
5.1. IEC 61850-3 EMI Type Tests ........................................................................................... 43
5.2. IEEE 1613 (C37.90.x) EMI Immunity Type Tests ............................................................. 44
5.3. Environmental Type Tests ................................................................................................ 44
6.1. Agency Approvals ............................................................................................................. 45
RuggedCom® RuggedBackbone™
7
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
FCC Statement And Cautions
FCC Statement And Cautions
Federal Communications Commission Radio Frequency Interference
Statement
This equipment has been tested and found to comply with the limits for a Class A digital device
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense.
Caution: LASER
This product contains a LASER system and is classified as a CLASS 1 LASER
PRODUCT. Use of controls or adjustments or performance of procedures other than
those specified herein may result in hazardous radiation exposure.
Caution: Service
This product contains no user-serviceable parts. Attempted service by unauthorized
personnel shall render all warranties null and void.
Changes or modifications not expressly approved by RuggedCom Inc. could invalidate
specifications, test results, and agency approvals, and void the user’s authority to
operate the equipment.
Caution: Physical Access
This product should be installed in a restricted access location where access can only
be gained by service personnel or users who have been instructed about the reasons
for the restrictions applied to the location and about any precautions that shall be taken;
and access is through the use of a tool or lock and key, or other means of security,
and is controlled by the authority responsible for the location.
RuggedCom® RuggedBackbone™
8
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Product Overview
1. Product Overview
1.1. Functional Overview
The RuggedBackbone™ RX1501 is a cost-efficient, rugged layer 3 switch and router. The
RX1501’s modular and field replaceable platform allows you to select WAN, serial, and Ethernet
options, making it ideally suited for electric power utilities, the industrial plant floor, and traffic
control systems.
The RX1501 is designed to the RuggedRated™ specification, providing a high level of immunity to
electromagnetic interference (EMI) and heavy electrical surges typical of the harsh environments
found in many industrial applications. An operating temperature range of -40°C to +85°C (-40°F
to +185°F) allows the RX1501 to be placed in almost any location.
1.2. Feature Highlights
Cyber Security Features
• Multi-level passwords
• SSH/SSL encryption
• Enable/disable ports, MAC-based port security
• Port-based network access control (802.1x)
• VLAN (802.1Q) to segregate and secure network traffic
• RADIUS centralized password management
• SNMPv3 encrypted authentication and access security
RuggedRated™ for Reliability in Harsh Environments
• Immunity to EMI and high voltage electrical transients:
• Zero-Packet-Loss Technology
• Meets IEEE 1613 (electric utility substations)
• Exceeds IEC 61850-3 (electric utility substations)
• Exceeds IEC 61800-3 (variable speed drive systems)
• Exceeds IEC 61000-6-2 (generic industrial environment)
• -40°C to +85°C operating temperature (no fans)
• Optional conformal coated printed circuit boards
• Failsafe Output Relay: For critical failure or error alarming
Physical Ports
• Field replaceable line modules
• Up to 36 ports 100FX
• Up to 36 ports 10/100TX
• Up to 8 ports Gigabit Ethernet
RuggedCom® RuggedBackbone™
9
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Product Overview
WAN Port Options
• Up to 4 T1/E1 ports via RJ45 connectors (channelized/unchannelized)
• Up to 2 E1 ports via BNC connectors (channelized/unchannelized)
• Cellular/DDS
Serial Ports
• Fully compliant EIA/TIA RS485, RS422, RS232 serial ports (software selectable) with RJ45
connectors
• Raw socket mode support allows conversion of any serial protocol
Protocols
WAN
•
• Frame Relay RFC 1490 or RFC 1294
• PPP RFC 1661, 1332, 1321, 1334, PAP, CHAP Authentication
• Multilink PPP RFC 1990
• GOOSE messaging support
IP
•
• Routing: OSPF, BGP, RIPv1, RIPv2
• VRRP Agent
• Traffic control, NTP Server, IP Multicast Routing
• DHCP Agent (Option 82 Capable)
Frame Relay Support
• ISO and ITU compliant, network certified.
• ANSI T1.617 Annex D, Q.933 or LMI Local Signaling
Management Tools
• Web-based, SSH, CLI management interfaces
• SNMP v1, v2, and v3
• Remote Syslog
• Rich set of diagnostics with logging and alarms
• Loopback diagnostic tests
• Raw and interpreted real-time line traces
RuggedCom® RuggedBackbone™
10
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Product Overview
Universal Power Supply Options
• Single, removable power supply module
• Single power supply
• Fully integrated power supply (no external adaptor)
• Input voltage ranges: 10-36VDC, 36-72VDC, 88-300VDC, 85-264VAC
• TUV/UL 60950 safety approved to 85°C
Warranty
• 5 Year Warranty
RuggedCom® RuggedBackbone™
11
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
2. RuggedBackbone™ Modules
2. RuggedBackbone™ Modules
The RX1501 chassis provides seven module slots . Each slot accommodates a particular type
on the RX1501.
Figure 2.1. RX1501 Chassis Slot Assignment
The RX1501 chassis supports the following modules:
LM1 through LM6
The RX1501 chassis supports up to six line module (LM) cards. For more information on line
All modules are built to the RuggedRated™ specifications of the RuggedBackbone™ RX1501.
Each module type is described in the following sections.
To install a module into the RuggedBackbone™ chassis, align the module guide ribs
with the channels on the chassis. Push the module in as far as it will go, being sure to
push through the resistance provided by the grounding springs. When properly seated,
the module flange will rest on the main chassis frame. Tighten the thumbscrews using
finger strength only.
RuggedCom® RuggedBackbone™
12
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
2. RuggedBackbone™ Modules
2.1. Front Panel
The RX1501 Front Panel is equipped with an RS232 serial console port for initial management
functions, and a locally connected 10/100Base-T Ethernet port for system management out of
band from the switch fabric.
Figure 2.2. Front View - RX1501
Other Front Panel features include:
• Utility USB port.
• Power module indicator LED.
• Line module indicator LEDs.
• Alarm Indicator LED, which indicates system alarm status.
• Lamp Test / Alarm Cutoff (LT/ACO) button.
• Removable 1GB Compact Flash (CF) card, which contains active and fallback installations of
the ROX™ operating system, along with the configuration database and other system data.
• Chassis ground connection.
For more information on connecting to the ports on the front panel, see the following topics:
2.1.1. Module Status LEDs
The front panel module status LEDs provide the following information:
LED
Purpose
Description
I = Power supply is receiving input voltage.
O = Power supply is providing
PM1
Indicates power supply status.
output voltage to the RX1501.
Green = OK
LM 1 through 6
Indicates the line module status.
Orange = Warning alert
Red = Configuration error
Table 2.1. Module Status LED Indications
RuggedCom® RuggedBackbone™
13
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
2. RuggedBackbone™ Modules
2.2. Line Modules (LM)
The RuggedBackbone™ RX1501 supports six line modules in slots LM1 through LM6 . Several
types of line modules may be ordered, depending on the type, speed, and number of Ethernet
ports required.
The following illustrations show the typical port configurations and connectors available for
RX1501 line modules. For complete information on the available line modules, refer to the
RuggedBackbone™ RX1501 data sheet.
Only one T1/E1 module may be used per router.
On the RX1501, 2-port modules can only be inserted in LM1 and LM2.
2.2.1. Ethernet - Copper
Figure 2.3. CG01: 2 × 10/100/1000TX RJ45
Figure 2.4. 6TX01: 6 × 10/100/1000TX RJ45
2.2.2. Ethernet - Fiber
Figure 2.5. FX**/FG**: 2 × 100FX/1000SX/1000LX LC
Figure 2.7. FX03: 2 × 100 FX MTRJ
Figure 2.9. FX**: 2 × 100FX SC
Figure 2.6. 4FX**: 4 × 100FC LC
Figure 2.8. 4FX03: 4 × 100FX MTRJ
Figure 2.10. FX**: 2 × 100FX ST
Figure 2.11. 10FL: 3 × 10FL ST
RuggedCom® RuggedBackbone™
14
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
2. RuggedBackbone™ Modules
2.2.3. SFP Modular
Figure 2.12. FG5*: 2 × 1000LX/1000SX SFP
Figure 2.13. FX5*: 4 × 100FX/100LX/100SX SFP
Figure 2.14. 6FX50: 6 × 100FX SFP
2.2.4. WAN
Figure 2.15. TC1: 1 × T1/E1 RJ45
Figure 2.17. TC2: 2 × T1/E1 RJ45
Figure 2.16. E01: 1 × E1 BNC
Figure 2.18. E02: 2 × E1 BNC
Figure 2.19. TC4: 4 × T1/E1 RJ45
2.2.5. Serial
Figure 2.20. 6S01: 6 × Serial RJ45
2.2.6. Cellular Modem
Figure 2.21. W11, W21, W32 Cellular Modem
Figure 2.22. W12, W22 Cellular Modem
RuggedCom® RuggedBackbone™
15
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
2. RuggedBackbone™ Modules
2.3. Power Supply
The RX1501 is equipped with a single power module.
A single power module is capable of delivering a maximum of 42W, and accepts either AC or DC
power at its input.
Power modules may be ordered with a screw terminal block or with a pluggable terminal block. The
screw terminal block features a safety cover which must be removed to make wiring connections,
and must be replaced after wiring is complete.
Power modules may be ordered as separate components. Refer to the RX1501 data sheet for
complete ordering details.
Figure 2.25. Screw terminal block power module: terminal cover in place (HI module shown)
Figure 2.26. Screw terminal block power module: terminal cover removed (HI module shown)
Figure 2.27. Pluggable terminal block power module (HIP module shown)
RuggedCom® RuggedBackbone™
17
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Installation
3. Installation
3.1. Rack Mounting
The RuggedBackbone™ RX1501 mounts to a standard 19" rack. Rack mounting brackets can be
installed at the front or rear of the chassis. Placing the connectors at the rear allows all data and
power cabling to be installed and connected on the same side of the rack.
Remove the black pan head Phillips screws from the front or rear mounting locations. Position
the rack mounting bracket, aligning the holes in the bracket with the screw holes on the chassis.
Attach the mounting bracket with the screws from the chassis. Torque all screws to 10 in-lbs.
For high-vibration or seismically active locations, use rack mounting brackets at all four corners
of the chassis.
Due to the heat dissipated in the RX1501 chassis, it is recommended that 1 unit of rack
space (1U or 1.75") be left unpopulated and free of equipment above each RX1501 unit
to allow for convection airflow. Although forced airflow is not necessary, any increase
in airflow will result in a reduction of ambient temperature and will improve long-term
reliability of all equipment mounted in the rack.
REAR MOUNTING BRACKET
FRONT MOUNTING BRACKET
Figure 3.1. Side View of Mounting Brackets
3.1.1. Rack Mounting Dimensions
Figure 3.2. RX1501Rack Mounting Dimensions – Front View
RuggedCom® RuggedBackbone™
18
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Installation
3.1.2. Panel and DIN Rail Mounting
The RuggedBackbone™ RX1501 features optional mounting brackets for panel and DIN rail
mounting. The optional brackets attach to both sides of the appliance at the rear of the chassis.
For panel mounting, the mounting bracket provides four mounting holes. For DIN rail mounting,
the DIN adaptor mounts to a standard 1" DIN rail and is secured with a lock screw on each adaptor.
To attach the mounting brackets, remove the black pan head Phillips screws from side of the
appliance. Align the brackets with the threaded holes on the sides of the appliance. Secure the
mounting bracket with the screws from the chassis. Torque all screws to 10 in-lbs.
Figure 3.5. Installing Panel and DIN Rail Mounting Brackets
Figure 3.6. DIN Rail Mounting
RuggedCom® RuggedBackbone™
20
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Installation
3.2. Power Supply Wiring and Grounding
The RX1501 supports a single power supply, power module 1 (PM1). Power connections are
located on the PM1 module face plate. An optional chassis ground connection is located on the
RX1501 products can be equipped with either a Phillips Screw Terminal Block or a Phoenix Plug
Terminal Block. The Phillips Screw Terminal Block has Phillips screws with compression plates,
allowing either bare wire connections or crimped terminal lugs. We recommend the use of #6 size
ring lugs to ensure secure, reliable connections under severe shock or vibration. Both terminal
blocks have a safety cover, secured with two Phillips screws, which must be removed to make
connections. The safety cover must be re-attached after wiring to ensure personnel safety.
For AC and DC power supply wiring examples, refer to Section 3.2.4, “AC Power Supply Wiring
The RX1501 has one (1) power supply installed. Service personnel must isolate all
power supplies prior to servicing.
3.2.1. Connectors for HI and HIP Power Modules
Figure 3.8. Screw Terminal Power
Connector for HI Power Module
Figure 3.9. Pluggable Phoenix Power
Connector for HIP Power Module
3.2.2. Connectors for 24, 24P, 48, and 48P Power Modules
Figure 3.10. Screw Terminal Power
Figure 3.11. Pluggable Phoenix Power
Connector for 24 and 48 Power Modules
Connector for 24P and 48P Power Modules
RuggedCom® RuggedBackbone™
22
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Installation
3.2.3. Chassis Ground Connection
uses a #10-32 screw. It is recommended to terminate the ground connection in a #10 ring lug.
Torque on the chassis ground connection should not exceed 30 in-lbs (3.4 Nm).
Figure 3.12. Chassis Ground Connection
3.2.4. AC Power Supply Wiring Example
Figure 3.13. Wiring for Single AC Power Supply (HIP module shown)
• For 125/230VAC rated equipment, a appropriately rated AC circuit breaker must be
installed.
• It is recommended to provide a separate circuit breaker for each power supply
module.
• Equipment must be installed according to applicable local wiring codes.
RuggedCom® RuggedBackbone™
23
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Installation
3.2.5. DC Power Supply Wiring Example
+
Figure 3.14. Wiring for Single DC Power Supply (24P or 48P module shown)
• For 125/230VAC rated equipment, a appropriately rated AC circuit breaker must be
installed.
• It is recommended to provide a separate circuit breaker for each power supply
module.
• Equipment must be installed according to applicable local wiring codes.
3.3. Critical Alarm Wiring
The Critical Alarm output relay signals critical error conditions that may occur on the
RuggedBackbone™ RX1501. The contacts are energized upon power-up of the unit and remain
energized unless a critical alarm condition is detected. Relay connections are shown in the Critical
Alarm Relay Connector diagram. You can configure control of the relay output through the ROX™
user interface.
A common application for this output is to signal an alarm in case of a power failure.
Figure 3.15. Critical Alarm Relay Connector
RuggedCom® RuggedBackbone™
24
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Installation
3.4. Serial Console Port
The serial console port on the front panel provides access to the boot-time control and
configuration menu interface, and a console interface to the ROX™ operating system.
The serial ports implement RS232 DCE on a female DB9 connector. Serial settings are: 57600
bps, 8 bits, No parity, 1 stop bit. See the illustration and table below for pin configuration and
assignment.
DB9 Pin
Signal Function
1
2
3
4
5
6
7
8
9
NC
TX
RX
NC
GND
NC
NC
NC
NC
Figure 3.16. DB9 Serial Console Port
Table 3.1. DB9 Serial Console Pinout
3.5. WAN Ports: RJ45
The RX1501 supports T1/E1 WAN ports, to interface to standard T1 or E1 telecommunication
infrastructure. Carefully note the orientation of the RJ45 receptacle when inserting or removing
cabling. See the illustration and table below for pin configuration and assignment.
T1/E1 pinout
Pin
1
Description
RRING
RTIP
NC
2
3
4
TRING
TTIP
5
6
NC
7
NC
8
NC
Figure 3.17. RJ45 T1/E1 Pin Configuration
Table 3.2. RJ45 T1/E1 Pin Assignment
RuggedCom® RuggedBackbone™
25
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Installation
3.6. WAN Ports: BNC
The RX1501 supports optional E1 WAN ports with BNC connectors. The Tx and Rx connections
are labelled on the line module. See the illustration below for the connection configuration.
Rx
Tx
RTIP
TTIP
Chassis
Chassis
Figure 3.18. RJ45 T1/E1 Pin Configuration
3.7. Copper Ethernet Ports
The RuggedBackbone™ RX1501 can be ordered with up to 36 10/100Base-TX ports that allow
connection to standard CAT-5 UTP cable with RJ45 male connectors. All copper Ethernet ports
feature auto-negotiation, auto-polarity, and auto-crossover functions. The female RJ45 connector
can accept and take advantage of screened (commonly known as “shielded”) cabling.
3.7.1. RJ45 Twisted-Pair Copper Ports
Female RJ45 connectors are available on LMs that support 10/100Base-T and on LMs and SMs
that support 10/100/1000Base-T Ethernet. See the illustration and table below for pin configuration
and assignment.
10/100/1000Base-
RJ45 Pin
10/100Base-Tx
Tx
A+
A-
1
2
3
4
5
6
7
8
RX+
RX-
TX+
NC
B+
C+
C-
NC
TX-
NC
B-
D+
D-
Figure
3.19.
RJ45
Ethernet
Pin
NC
Configuration
Table 3.3. RJ45 Ethernet Pin Assignment
3.7.2. Gigabit Ethernet 1000Base-TX Cabling Recommendations
The IEEE 802.3ab Gigabit Ethernet standard defines 1000 Mbit/s Ethernet communications
over distances of up to 100 meters using 4 pairs of CAT-5 (or higher) balanced, unshielded
twisted-pair cabling. For wiring guidelines, system designers and integrators should refer to
the Telecommunications Industry Association (TIA) TIA/EIA-568-A wiring standard for minimum
cabling performance specifications required for proper Gigabit Ethernet operation. To ensure
reliable, error-free data communications, new and pre-existing communication paths should
be verified for TIA/EIA-568-A compliance. The table: Cabling Categories and 1000Base-
TX Compliance summarizes the relevant cabling standards as they apply to 100Base-TX
connections.
RuggedCom® RuggedBackbone™
26
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Installation
1000Base-
TX Compliant
Cabling Category
Required Action
< 5
5
No
New wiring infrastructure required.
Yes
Yes
Yes
Yes
Verify TIA/EIA-568-A compliance.
5e
6
No action required. New installations should be designed with Category 5e or higher.
No action required.
> 6
Connector and wiring standards to be determined.
Table 3.4. Cabling Categories and 1000Base-TX Compliance
Follow these recommendations for copper data cabling in high electrical noise environments:
• Data cable lengths should be as short as possible, ideally limited to 10' (3m) in length. Copper
data cables should not be used for inter-building communications.
• Power and data cables should not be run in parallel for long distances, and should be installed
in separate conduits. Power and data cables should intersect at 90° angles when necessary
to reduce inductive coupling.
• Optionally, shielded/screened cabling can be used. The cable shield should be grounded at one
single point to avoid the generation of ground loops.
3.7.3. Transient Suppression
All copper Ethernet ports on RuggedCom products include transient suppression circuitry to
protect against damage from electrical transients and to ensure conformance to IEC 61850-3
and IEEE 1613 Class 1. This means that during a transient electrical event, it is possible for
communications errors or interruptions to occur, but recovery is automatic.
RuggedCom does not recommend the use of copper cabling of any length for critical,
real-time, substation automation applications.
RuggedCom also recommends against the use of copper Ethernet connections to interface to
devices in the field across distances which could produce high levels of ground potential rise (that
is, greater than 2500V), during line-to-ground fault conditions.
RuggedCom® RuggedBackbone™
27
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Installation
3.8. Serial Ports: RJ45
The RX1501 supports serial port line modules with RJ45 connections. On power-up, all serial
ports default to RS485 mode. Each port can be individually set to RS232, RS485, or RS422 mode
via software.
Pin
RS232 Mode RS485 Mode RS422 Mode
1
RX-
Reserved
2
3
COM (Isolated GND)
COM (Isolated GND)
4
5
RX
TX
RX+
TX +
6
TX/RX +
7
8
CTS
RTS
TX/RX -
TX -
Shield
Chassis GND
Figure 3.20. RJ45 Serial Pin Configuration
Table 3.5. RJ45 RS232/RS485/RS422 Serial Pin
Assignment
Pin 2 is reserved for future IRIG-B output. Do not connect Pin 2 at this time; doing
so may cause hardware damage. Pins 7 and 8 are connected internally. No internal
termination is provided. In RS232 mode, these pins enter a high impedance state.
A DTE that asserts RTS will see CTS asserted, but hardware flow control is not
performed on the port.
3.9. DDS Ports: RJ45
The RX1501 supports DDS port line modules with RJ45 connections. The 56 kbps DDS port is
compatible with Bellcore standards. Each DDS module features a single 56/64 kbps DDS line
interface with a standard RJ45 receptacle.
RJ45 Pin
Description
1
2
3
4
5
6
7
8
R1: Transmit data to network (Ring 1)
T1: Transmit data to network (Tip 1)
NC
NC
NC
NC
T: Receive data from network (Tip)
R: Receive data from network (Ring)
Figure 3.21. RJ45 DDS Pin Configuration
Table 3.6. RJ45 DDS Pin Assignment
RuggedCom® RuggedBackbone™
28
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Installation
3.10. DDS Rx and Tx LED Indications
The DDS module features Rx and Tx LED indicators that display transmit and receive status.
Figure 3.22. DDS Module Rx and Tx LED Indicators
The following tables describe the DDS module Rx and Tx LED status indications:
Rx LED Color
GREEN
YELLOW
RED
Status
Frame sync detected and signal OK.
Signal OK, but no frame sync.
Loss of signal.
OFF
The interface is not enabled.
Table 3.7. DDS Rx LED Indications
Tx LED Color
GREEN
Status
The interface is enabled and remote device has no errors.
The interface is in loopback mode.
YELLOW
Loss of signal or receiving any of OOS, UNM, or UMC codes: the remote device is out of service
or has problems with the signal.
RED
OFF
The interface is not enabled.
Table 3.8. DDS Tx LED Indications
3.11. SFP Optics – Installation, removal, and precautions
The RX1501 can be ordered with SFP (Small Form-factor Pluggable) pluggable optics modules.
SFP modules can be safely inserted and removed while the chassis is powered and operating.
When inserting or removing optics, observe the following precautions:
• Ensure that dust caps are mounted on SFP cages at all times, unless you are in the process
of inserting or removing an SFP module. The dust caps prevent the accumulation of residue or
particles that might inhibit proper operation.
• Ensure that you have properly discharged any possible electrostatic build-up to prevent
electrostatic discharges (ESD). This can be accomplished by proper grounding through an ESD
wrist strap, or by touching earth or chassis ground before installing or removing optical modules.
ESD can damage or shorten the life of optical modules when they are not plugged into a chassis.
• Ensure that SFP optical modules are always stored in an ESD-safe bag or other suitable
ESD-safe environment. Keep SFP modules free from moisture and store them at the proper
temperature (-40°C to +85°C).
• Disconnect all cables from the SFP module before inserting or removing the module.
• Use only components certified by RuggedCom Inc. with RuggedCom products. Damage can
occur to optics and product if compatibility and reliability have not been properly assessed.
RuggedCom® RuggedBackbone™
29
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Installation
3.11.1. Module Insertion – SFP
Special attention must be paid to the orientation of SFP modules upon installation in the RX1501
chassis. The figure below shows the proper orientation of SFP modules installed in both upper and
lower line modules. SFP modules on the upper row must be inserted top-side up. SFP modules
on the lower row must be inserted top-side down. SFP modules should be inserted with the bail-
latch in the locked position.
Figure 3.23. SFP module orientation
Figure 3.24. SFP module insertion
SFP modules should slide gently into their ports and should lock in place when fully inserted.
Dust covers should be in place when installing the modules, and should always be in place when
cables are not connected.
3.11.2. SFP Module Removal
To remove the SFP module, disconnect any cables and replace the dust cover to protect the
optics. Extend the bail latch found on the top of the module. Grasp the bail latch and gently pull
outwards to unlock and remove the module.
Immediately after removal, store the SFP module in an ESD-safe environment.
RuggedCom® RuggedBackbone™
30
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Installation
Figure 3.25. SFP module removal
3.12. Fiber Ethernet Ports
Depending on the order code of the product, the RuggedBackbone™ RX1501 can be equipped
with several different types of fiber optic ports. The Transmit (TX) and Receive (RX) connections
of each port must be properly connected and matched for proper link establishment and operation.
The drawings in the following figures show a side and top view of each supported fiber optic
connector type to assist in identifying the proper cable connection orientation.
Tx Rx
Figure 3.26. LC
Figure 3.27. MTRJ
Tx
Rx
Tx
Rx
Figure 3.29. ST
Figure 3.28. SC
Table 3.9. Available Fiber Connector Types
RuggedCom® RuggedBackbone™
31
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Installation
3.13. Cellular Modems
The RX1501 can be equipped with cellular modem modules for operation on GSM, EDGE, HSPA
+, or CDMA networks. The cellular modems feature 50 Ω SMA antenna connectors on the front
plate of each module. The following cellular modem modules are available:
Module Order Code
Description
W11
W12
W21
W22
W32
1 Port Cell Modem GSM,EDGE,HSPA+
2 Port Cell Modem GSM,EDGE,HSPA+
1 Port Cell Modem EVDO Rev.A Verizon Wireless
2 Port Cell Modem EVDO Rev.A Verizon Wireless
1 Port Cell Modem GSM,EDGE,HSPA+, 1 Port Cell Modem EVDO Rev.A Verizon Wireless
Table 3.10. Cellular Modem Modules
Figure 3.30. Single Port Cellular Modem: Antenna Connections
Figure 3.31. Dual Port Cellular Modem: Antenna Connections
If two or more antennas are to be installed, the antennas must be separated by a
minimum distance of 20 cm (7.9").
RuggedCom® RuggedBackbone™
32
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Installation
3.13.1. GSM, EDGE, HSPA+ Cellular Modem Card
The HSPA option is available for use on various GSM based networks. This option supports GSM,
GPRS, EDGE, UMTS and WCDMA/HSDPA/HSUPA. The Main antenna and Receive Diversity
antenna connections are made to the 50 Ω SMA connectors located on either side of the front
faceplate.
Supported frequency bands are given in the following table. For safe operation of the device,
ensure that the maximum antenna gain is not exceeded.
Frequency Range
Maximum
Allowable
Gain (dBi)
RX Diversity
Support
Band
Tx (MHz)
VSWR
Rx (MHz)
VSWR
Band I
WCDMA 2100
1920-1980
<2.5:1
<2.5:1
<2.5:1
<2.5:1
<2.5:1
2110-2170
<3.5:1
Y
Y
Y
Y
Y
4
4
5
5
5
Band II
WCDMA 1900
1850-1910
880-915
824-849
830-840
1930-1990
925-960
869-894
875-885
<2.5:1
<3.5:1
<3.5:1
<3.5:1
Band VIII
WCDMA 900
Band V
WCDMA 850
Band VI
WCDMA 800
GSM 850
EGSM 900
GSM 1800
GSM 1900
824-849
880-915
<2.5:1
<2.5:1
<2.5:1
<2.5:1
869-894
925-960
<3.5:1
<3.5:1
<3.5:1
<2.5:1
5
5
4
4
1710-1785
1850-1910
1805-1880
1930-1990
Table 3.11. HSPA Antenna Requirements
3.13.2. Installing SIM Cards for GSM, EDGE, HSPA+ Cellular Modems
Be sure to take appropriate anti-static precautions before opening the cellular modem
module.
1. Remove the module from the RX1501.
2. On the smooth side of the module, remove the four screws and remove the back of the module.
Figure 3.32. Cellular Modem Module Assembly:
W11 and W32 Single Antenna Modules
Figure 3.33. Cellular Modem Module
Assembly: W12 Dual Antenna Modules
RuggedCom® RuggedBackbone™
33
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Installation
3. Note the location of the SIM card cages. For modules W11 and W32, install the SIM card in
SIM 1. For module W22, install a SIM card in both SIM 1 and SIM 2.
4. Top open a SIM card cage, slide the silver catch down towards the antenna connector end
of the module and flip the cage open.
5. Hold the SIM card at its notched end, with its connectors facing down, and insert the SIM
card into the cage.
6. Flip the cage down and slide the silver catch up away from the antenna connector end of
the module.
7. Replace the back of the module and secure the back of the module with the four screws
removed earlier.
8. Re-install the module in the RX1501.
RuggedCom® RuggedBackbone™
34
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Installation
3.14. APE: Application Processing Engine
3.14.1. APE Overview
The APE (Application Processing Engine) is an x86-based computer designed to occupy a single
line module slot on the RX1501. The APE can host any x86-based operating system capable of
running on a computer with similar specifications, and features a Gigabit Ethernet connection on
the module faceplate. You can use the APE for a variety of functions, such as network monitoring,
specialized applications, DNS applications, and more.
Feature
Processor
RAM
Description
Intel Atom E660T 1.3 GHz
2 GB DDR2
Disk
8 GB SATA, solid state
1 × RJ45 Gigabit Ethernet interface, faceplate connector
1 × Gigabit Ethernet interface, connected to internal RX1501 switch
Network
2 × USB 2.0. Maximum USB device power consumption, through single port or combined through both ports:
250 mA at 5 V.
USB
Video
DVI-D
• Power
LED Indicators
• Disk Activity
Controls
Momentary contact reset button
Supports any x86-compatible operating compatible with hardware specifications. For a list of tested and
Operating System
Table 3.12. APE Specifications
Figure 3.34. APE Faceplate and Ports
3.14.2. Supported Operating Systems
The APE supports any x86-compatible operating system. The following operating systems have
been tested and confirmed to work with the APE module:
• Microsoft Windows Embedded Standard 7
• Debian GNU/Linux 6
• Ubuntu 11.04
• Linux Mint 10
• OpenSuse 11.4
RuggedCom® RuggedBackbone™
35
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Installation
3.14.3. Secondary Network Interface
In addition to the gigabit Ethernet interface on the faceplate, the APE features a gigabit Ethernet
interface connecting to a port on the RX1501 chassis. The interface can be used by the operating
system running on the APE as a normal network interface. The port can be configured from ROX™.
Typical port parameters, such as speed, duplex, vlans, and more, can be configured. From the
perspective of the RX1501, the port is just switch port where a device is connected.
Figure 3.35, “APE Chassis Network Connection” shows how the APE and the RX1501 are
connected. The APE module can have connectivity to devices or networks connected to regular
ports on the RX1500.
Figure 3.35. APE Chassis Network Connection
3.14.3.1. Placing the APE in a VLAN
The port connecting the APE to the RX1501 is a normal switch port. The port PVID can be changed
through ROX™ as can be done with any other switch port. For example, if the APE is Line Module
2 (LM2), then setting the lm2/1 pvid parameter to 10 places the APE secondary network interface
connection on VLAN 10.
RuggedCom® RuggedBackbone™
36
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Installation
3.14.4. Installing an Operating System
We recommend that the operating system be installed and configured by users with
experience in installing and administering the chosen operating system.
To install an operating system on the APE, you need the following items:
• DVI-D monitor.
• Keyboard with USB connector.
• Bootable USB flash drive or USB external CD/DVD drive with your operating system installation
package.
When using an external drive that is powered through the USB port, ensure that the
total power consumption through both USB ports does not exceed 250 mA at 5V.
To connect additional USB devices, such as a mouse, you can attach a USB hub to
the APE. Again, ensure that the total power consumption through both USB ports does
not exceed 250 mA at 5V.
Procedure 3.1. To install an operating system:
1. Ensure that the APE module is inserted properly into the line module slot and that the RX1501
is powered up. The APE module power LED should be ON and orange.
2. Connect your monitor to the DVI-D connector, connect your keyboard to a USB port, and
connect your bootable USB device to a USB port.
If your operating system installation package requires a network connection, connect a
network cable to the Ethernet port. Connect the other end of the cable to a functioning network
port.
3. With a pin or small screwdriver, press and release the APE reset button.
4. After the APE boots, press the F2 key. The BIOS screen appears.
5. Navigate to the Boot menu. Move the USB device to the first boot priority.
Your bootable USB device must be connected to the APE for you to be able to
set the device’s boot priority.
6. Navigate to the Exit menu and select Exit Saving Changes. The APE restarts and boots
from the connected USB device.
7. Follow the prompts and instructions from your operating system installation package. Detailed
installation instructions are beyond the scope of this guide. For detailed instructions on
installing your operating system, refer to the operating system documentation.
8. After installing the operating system, you may need to change the boot priority back to the
APE’s internal drive. Reboot the APE and press F2 as the module reboots. Navigate to the
Boot menu and move the internal drive to the first boot priority. Navigate to the Exit menu
and select Exit Saving Changes. The APE restarts and boots from the internal drive.
It is also possible to run a live operating system from the USB device itself. However,
this may result in slower overall performance of the operating system.
RuggedCom® RuggedBackbone™
37
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Installation
3.14.5. The APE BIOS
The APE module features a BIOS with functionality similar to that of a typical PC. You can
configure the following BIOS settings:
• System Time
• Processor Options
• Boot Options
• Security Options
For most purposes, these options are used sparingly unless there is a specific hardware or
software requirement that requires a change. The most commonly changed options are the boot
options, as the USB ports need to be made bootable to install an operating system.
To display the BIOS menus, press F2 while powering on the APE. To display BIOS help, press
F1 and follow the instructions at the bottom of the screen.
3.14.6. Resetting the Module
Whenever possible, shut down and reboot the APE from the operating system instead of
performing a hard reset with the reset button. This helps to ensure graceful shutdowns and data
integrity. If absolutely required, you can perform a hard reset with the reset button on the APE
faceplate.
The reset button is recessed from the front surface of the faceplate. Use a pin or small screwdriver
to reach the button.
To reset the APE, depress and hold the reset button until the power LED turns orange. Then,
release and push the reset button again. The power LED turns green as the module reboots.
3.14.7. LED Indicators
LED Indicator
LED Color and State
Description
Power LED
Green, steady
APE module is on and functioning correctly.
APE module is not receiving
enough power or is shut down.
Power LED
Disk LED
Orange, steady
Indicates read and write
activity to the solid state drive.
Green, steady or blinking.
Ethernet Port LED
Green, steady or blinking.
Indicates incoming and outgoing network activity.
Table 3.13. APE Module LED Indicators
RuggedCom® RuggedBackbone™
38
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Installation
3.14.8. FAQs
Q: How do I use a CD or DVD to install an operating system on the APE module?
A: Connect an external CD/DVD drive to one of the APE USB ports. If the external drive is
powered through the USB port, ensure that it does not exceed the USB port power limitations
(250 mA at 5 V), or use a drive that has an external power supply.
Q: How do I install Windows from a USB flash drive?
A: There are many articles on the Internet explaining how to do this. We recommended
selecting a method that uses the least amount of third-party software to create the bootable
USB drive.
Q: Can I shutdown or power-up the APE module from ROX™?
A: Not currently. In ROX™ version 2.2, the APE is isolated from ROX™ control. ROX™
can identify the type of module present in the RX1501 line module slot, and can monitor
temperature information for the APE module.
Q: Can I connect to the operating system running on the APE from one of the ports on the
other slots?
A: Yes. In ROX™, assign lm{APE_slot}/1, where {APE_slot} is the line module slot where
the APE is installed, to the VLAN on which connectivity is expected. The APE should be
reachable from any device belonging to the same VLAN.
If you want the APE be routable, log in to the operating system on the APE and set the
secondary interface gateway to the IP address of the ROX™ VLAN.
Q: Can I use the APE module as a DHCP server or a DNS server?
A: Yes. The APE module supports any x86-compatible operating system and the services
offered by the system.
RuggedCom® RuggedBackbone™
39
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Technical Specifications
4. Technical Specifications
4.1. Power Supply Specifications
Input Range
Power
Internal
Fuse Rating
Max. Power
Max Power
Output
Connections
Supply Type
Consumptiona
Min
Max
88 VDC
85 VAC
88 VDC
85 VAC
300 VDC
264 VAC
300 VDC
264 VAC
Screw
terminal block
HI
2A(T)b
52W Max
52W Max
42W
42W
Pluggable
terminal block
HIP
2A(T)b
Screw
terminal block
24
24P
48
10 VDC
10 VDC
36 VDC
36 VDC
36 VDC
36 VDC
72 VDC
72 VDC
2A(T)b
2A(T)b
2A(T)b
2A(T)b
52W Max
52W Max
52W Max
52W Max
42W
42W
42W
42W
Pluggable
terminal block
Screw
terminal block
Pluggable
terminal block
48P
a Power consumption varies based on configuration.
b (T) denotes time-delay fuse.
Table 4.1. Power Supply Specifications
4.2. Critical Alarm Relay Specifications
Voltage
Current
30VDC
250VAC
5A
6.25A
Table 4.2. Form C Contact Relay Specifications
4.3. Copper Ethernet Port Specifications
The RX1501 can be ordered with several different modules which contain 10/100Tx or
10/100/1000Tx Ethernet ports. All copper Ethernet ports have the following specifications:
Parameter
Speed
Specification
10/100 or 10/100/1000 Mbps
FDX / HDX
Notes
Auto-negotiating
Duplex
Auto-negotiating
Cable-Type
Wiring Standard
Max Distance
Connector
Isolation
> Category 5
TIA/EIA T568A/B
100 m
Shielded/Unshielded
Auto-Crossover, Auto-Polarity
RJ45
1.5kV
RMS 1-minute
Table 4.3. Copper Ethernet Port Specifications
RuggedCom® RuggedBackbone™
40
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Technical Specifications
4.4. Fiber Ethernet Port Specifications
The following sections detail fiber optic specifications for ports that can be ordered with the
modules on a RuggedBackbone™ RX1501. The user determines the type of optics at time of
ordering, and can determine the modules installed on a particular unit by reading the factory data
file via the ROX™ user interface. Section 4.4.1, “Fast Ethernet (100Mbps) Optical Specifications”
the optical transceivers used in the fiber Ethernet modules available for the RX1501. The
specifications are organized by order code. Module order codes are contained within each unit
when it is assembled and configured at the factory. Consult the RuggedCom ROX™ User Guide
for help in obtaining the factory configuration data.
4.4.1. Fast Ethernet (100Mbps) Optical Specifications
Fixed Fast Ethernet Transceivers
Rx
Rx
Distance
(typ.)
(km)
Power
Budget
(dB)
Cable
Order
Code
Connector
Type
Tx min.
(dBm)
Tx max.
(dBm)
Tx λ (typ.)
Mode
Sensitivity Saturation
(dBm)
Type (µm)
(nm)
(dBm)
62.5/125
50/125
-19
-22.5
-19
12
8.5
12
FX01
FX02
MM
ST
1300
-14
-31
-14
2
62.5/125
50/125
MM
MM
MM
SC
LC
1300
1300
1300
-14
-14
-14
-31
-32
-31
-14
-14
-14
2
2
2
-22.5
8.5
FX11 and
4FX11
9/125
-19
13
62.5/125
50/125
9/125
-19
-22.5
-15
12
8.5
17
16
FX03 and
4FX03
MTRJ
FX04
FX05
SM
SM
ST
SC
1300
1300
-8
-8
-32
-31
-3
-7
20
20
9/125
-15
FX06 and
4FX06
SM
SM
SM
SM
SM
LC
SC
LC
SC
LC
9/125
9/125
9/125
9/125
9/125
1300
1300
1300
1300
1300
-15
-5
-5
0
-8
0
-34
-34
-35
-37
-37
-7
-3
3
20
50
50
90
90
19
29
30
37
37
FX07
FX08 and
4FX08
0
FX09
5
0
FX10 and
4FX10
0
5
0
Table 4.4. Fast Ethernet (100Mbps) Optical Specifications
SFP Fast Ethernet Transceivers
Rx
Rx
Distance
Power
Budget
(dB)
Cable
Order
Code
Connector
Type
Tx min
(dBm)
Tx max
(dBm)
Tx λ (typ.)
Mode
Sensitivity Saturation (typ.)
(dBm)
Type (µm)
(nm)
(dBm)
(km)
62.5/125
50/125
9/125
-20
-23.5
-15
-5
11
7.5
16
29
29
FX51
MM
LC
1310
-14
-31
-14
2
FX52
FX53
FX54
SM
SM
SM
LC
LC
LC
1300
1300
1550
-8
0
-31
-34
-34
-8
0
20
50
90
9/125
9/125
-5
0
-10
Table 4.5. SFP Fast Ethernet Transceivers
RuggedCom® RuggedBackbone™
41
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Technical Specifications
4.4.2. Gigabit Ethernet (1Gbps) Optical Specifications
Fixed Gigabit Transceivers
Rx
Rx
Distance
(typ.)
(km)
Power
Budget
(dB)
Cable
Order
Code
Connector
Type
Tx min
(dBm)
Tx max
(dBm)
Tx λ (typ.)
Mode
Sensitivity Saturation
(dBm)
Type (µm)
(nm)
(dBm)
FG01
FG02
FG03
FG04
FG05
MM
SM
SM
SM
SM
LC
SC
LC
SC
LC
50/125
9/125
9/125
9/125
9/125
850
-9
-10
-9.5
-5
-2.5
-3
-20
0
0.5
10
10
25
25
11
10
1310
1310
1310
1310
-20
-3
-3
-3
-3
-3
-21
11.5
15
0
-20
-7
-3
-24
17
Table 4.6. Fixed Gigabit Transceivers
SFP Gigabit Transceivers
Rx
Rx
Distance
Power
Budget
(dB)
Cable
Order
Code
Connector
Type
Tx min
(dBm)
Tx max
(dBm)
Tx λ (typ.)
Mode
Sensitivity Saturation (typ.)
(dBm)
Type (µm)
(nm)
(dBm)
(km)
50/125
62.5/125
9/125
0.5
0.3
10
25
70
FG51
MM
LC
850
-9
-2.5
-20
0
11
FG52
FG53
FG54
SM
SM
SM
LC
LC
LC
1310
1310
1550
-9.5
-7
-3
-3
5
-19
-23
-23
-3
-3
-3
9.5
16
23
9/125
9/125
0
Table 4.7. SFP Gigabit Transceivers
Notes:
1. Maximum segment length is greatly dependent on factors such as fiber quality, and
the number of patches and splices. Please consult RuggedCom sales associates when
determining maximum segment distances.
2. All optical power numbers are listed as dBm averages.
3. F51 transceivers are rated for -40°C to +85°C.
4.5. Operating Environment
Parameter
Range
Comments
Ambient Temperature as measured from a 30cm
radius surrounding the center of the enclosure.
Ambient Operating Temperature
Table 4.8. Operating Environment
-40°C to 85°C
4.6. Mechanical Specifications
Parameter
Value
Comments
1.74 × 17.36 × 11.9 inches
44.20 × 440.94 × 302.26 mm
Dimensions
(Height × Width × Depth)
Weight
Approximately 10.3 lbs (4.7 kg)
Weight dependent on module selection.
Ingress Protection
IP40
Enclosure
Aluminum
Table 4.9. Mechanical Specifications
RuggedCom® RuggedBackbone™
42
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
5. EMI And Environmental Type Tests
5. EMI And Environmental Type Tests
Severity
Levels
Test
Description
Enclosure Contact
Test Levels
+/- 8 kV
+/- 15 kV
20 V/m
4
IEC 61000-4-2
IEC 61000-4-3
ESD
Enclosure Air
Enclosure Ports
Signal ports
4
Notea
Notea
4
Radiated RFI
+/- 4kV @ 2.5kHz
+/- 4kV
D.C. Power ports
A.C. Power ports
Earth ground ports
IEC 61000-4-4
Burst (Fast Transient)
+/- 4kV
4
+/- 4kV
4
+/- 4kV line-to-earth,
+/- 2kV line-to-line
Signal ports
4
3
4
+/- 2kV line-to-earth,
+/- 1kV line-to-line
IEC 61000-4-5
Surge
D.C. Power ports
A.C. Power ports
+/- 4kV line-to-earth,
+/- 2kV line-to-line
Signal ports
10V
10V
10V
10V
3
3
3
3
D.C Power ports
A.C. Power ports
Earth ground ports
IEC 61000-4-6
IEC 61000-4-8
Induced (Conducted) RFI
Magnetic Field
40 A/m, continuous,
1000 A/m for 1 s
Notea
5
Enclosure Ports
1000 A/m for 1 s
30% for 0.1s, 60% for
0.1s, 100% for 0.05s
D.C. Power ports
A.C. Power ports
A.C. Power ports
Signal ports
N/A
IEC 61000-4-29
IEC 61000-4-11
Voltage Dips & Interrupts
Voltage Dips & Interrupts
30% for 1 period,
60% for 50 periods
N/A
N/A
3
100% for 5 periods,
100% for 50 periods
2.5kV common, 1kV
diff. mode@1MHz
2.5kV common, 1kV
diff. mode@1MHz
IEC 61000-4-12
Damped Oscillatory
D.C. Power ports
A.C. Power ports
3
2.5kV common, 1kV
diff. mode@1MHz
3
Signal ports
30V Continuous, 300V for 1s
30V Continuous, 300V for 1s
4
4
IEC 61000-4-16
IEC 61000-4-17
Mains Frequency Voltage
D.C. Power ports
Ripple on D.C.
Power Supply
D.C. Power ports
10%
3
Signal ports
D.C. Power ports
A.C. Power ports
Signal ports
2kVAC (Fail-Safe Relay output)
N/A
N/A
N/A
N/A
N/A
N/A
IEC 60255-5
IEC 60255-5
Dielectric Strength
H.V. Impulse
1.5kVDC
2kVAC
5kV (Fail-Safe Relay output)
D.C. Power ports
A.C. Power ports
5kV
5kV
a RuggedCom-specified severity levels
Table 5.1. IEC 61850-3 EMI Type Tests
RuggedCom® RuggedBackbone™
43
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
5. EMI And Environmental Type Tests
Test
Description
Enclosure Contact
Test Levels
+/-2kV, +/-4kV, +/- 8kV
IEEE C37.90.3
IEEE C37.90.2
ESD
Enclosure Air
Enclosure ports
Signal ports
+/-4kV, +/-8kV, +/-15kV
Radiated RFI
35 V/m
+/- 4kV @ 2.5kHz
D.C. Power ports
A.C. Power ports
Earth ground ports
Signal ports
+/- 4kV
IEEE C37.90.1
Fast Transient
+/- 4kV
+/- 4kV
2.5kV common mode @1MHz
IEEE C37.90.1
IEEE C37.90
IEEE C37.90
Oscillatory
H.V. Impulse
D.C. Power ports
A.C. Power ports
Signal ports
2.5kV common, 1kV diff. mode@1MHz
2.5kV common, 1kV diff. mode@1MHz
5kV (Fail-Safe Relay output)
D.C. Power ports
A.C. Power ports
Signal ports
5kV
5kV
2kVAC
1.5kVDC
2kVAC
Dielectric Strength
D.C. Power ports
A.C. Power ports
a Meets Class 2 requirements for an all-fiber configuration. Meets Class 1 requirements for copper ports.
Table 5.2. IEEE 1613 (C37.90.x) EMI Immunity Type Testsa
Test
Description
Cold Temperature
Test Levels
-40°C, 16 Hours
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60255-21-1
IEC 60255-21-2
Test Ad
Test Bd
Test Db
Dry Heat
Humidity (Damp Heat, Cyclic)
Vibration
+85°C, 16 Hours
95% (non-condensing), 55°C , 6 cycles
2g @ (10 - 150) Hz
Shock
30g @ 11mS
Table 5.3. Environmental Type Tests
RuggedCom® RuggedBackbone™
44
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Agency Approvals
6. Agency Approvals
Agency
Standards
Comments
UL 60950-1:2007,
CAN/CSA-C22.2 No. 60950-1-07
TUV
CE Compliance is claimed via
Declaration of Self Conformity Route
CE
EN 60950, EN 61000-6-2
FCC
CISPR
FCC Part 15, Class A
EN55022, Class A
FDA/CDRH
21 CFR Chapter 1, Subchapter J
Laser Eye Safety
Designed and manufactured using an
ISO9001: 2008 certified quality program
ISO
ISO9001:2008
Table 6.1. Agency Approvals
RuggedCom® RuggedBackbone™
45
RX1501 Installation Guide Rev 104
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Warranty
7. Warranty
RuggedCom warrants this product for a period of five (5) years from the date of purchase. This
product contains no user-serviceable parts. Attempted service by unauthorized personnel shall
your customer service representative.
Should this product require service, contact the factory at:
RuggedCom Inc.
300 Applewood Crescent
Concord, Ontario
Canada L4K 5C7
Phone: +1 905 856 5288
Fax: +1 905 856 1995
RuggedCom® RuggedBackbone™
46
RX1501 Installation Guide Rev 104