Rose electronic Switch rosecom User Guide

ULTRAVIEW REMOTE 2  
KVM Access Over IP  
INSTALLATION AND OPERATIONS  
MANUAL  
10707 Stancliff Road  
Houston, Texas 77099  
Phone (281) 933-7673  
Internet: WWW.ROSE.COM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE of CONTENTS  
Contents  
Page  
Disclaimer........................................................................................................................................................................ 1  
Introduction...................................................................................................................................................................... 1  
Features .......................................................................................................................................................................... 2  
Compatibility.................................................................................................................................................................... 2  
Rose Electronics web site ............................................................................................................................................... 3  
Product Registration........................................................................................................................................................ 3  
System overview ............................................................................................................................................................. 4  
UltraView Remote 2 Installation ...................................................................................................................................... 6  
Connecting the KVM station ........................................................................................................................................ 6  
Connecting the Computers / Servers .......................................................................................................................... 7  
Connecting to the network........................................................................................................................................... 7  
Configuring the UltraView Remote 2 IP Input module................................................................................................. 9  
Logoff.............................................................................................................................................................................12  
Restore mouse functions...............................................................................................................................................12  
Configuration .................................................................................................................................................................12  
Access mode.................................................................................................................................................................12  
Host ...............................................................................................................................................................................12  
Return to host................................................................................................................................................................12  
Connecting Remotely....................................................................................................................................................13  
Remote Configuration ...................................................................................................................................................13  
User Accounts ...............................................................................................................................................................14  
Unit Configuration..........................................................................................................................................................15  
Time and Date Configuration ........................................................................................................................................17  
Network configuration....................................................................................................................................................18  
Host Configuration.........................................................................................................................................................19  
Logging and Status .......................................................................................................................................................20  
KVM Switch Module Configuration................................................................................................................................21  
Configure System..........................................................................................................................................................22  
Expansion ..................................................................................................................................................................22  
Scan settings .............................................................................................................................................................23  
Configure computers.....................................................................................................................................................24  
Configure overlay.......................................................................................................................................................25  
Miscellaneous ............................................................................................................................................................25  
Computer select window............................................................................................................................................26  
Security..........................................................................................................................................................................29  
Remote System Operation............................................................................................................................................30  
Connecting using a web browser ..............................................................................................................................30  
VNC Viewer Toolbar......................................................................................................................................................31  
Controls Tab..................................................................................................................................................................31  
Host Tab........................................................................................................................................................................33  
Keyboard Commands....................................................................................................................................................35  
Troubleshooting.............................................................................................................................................................36  
Maintenance and Repair ...............................................................................................................................................38  
Technical Support .........................................................................................................................................................38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figures  
Page  
Figure 1. UltraView Remote 2 Models ............................................................................................................................ 5  
Figure 2. Connecting a KVM........................................................................................................................................... 6  
Figure 3. Connecting Computers .................................................................................................................................... 7  
Figure 4. Connecting to the Network .............................................................................................................................. 7  
Figure 5. Cascading units ............................................................................................................................................... 8  
Figure 6. Configuration Menu.......................................................................................................................................... 9  
Figure 7. Unit Configuration Menu .................................................................................................................................. 9  
Figure 8. Network Configuration Menu ......................................................................................................................... 10  
Figure 9. Secure Keys Encryption................................................................................................................................. 11  
Figure 10. Logon screen ............................................................................................................................................... 11  
Figure 11. Remote Configuration Menu........................................................................................................................ 13  
Figure 12. Main configuration menu (Ctrl + F12) .......................................................................................................... 21  
Figure 13. Configure system menu............................................................................................................................... 22  
Figure 14. Configure computers.................................................................................................................................... 24  
Figure 15. Configure overlay......................................................................................................................................... 25  
Figure 16. Configure security........................................................................................................................................ 29  
Figure 17. VNC Viewer Toolbar .................................................................................................................................... 31  
Figure 18. Host Configuration window.......................................................................................................................... 33  
Figure 19. Computer Select Window ............................................................................................................................ 34  
Tables  
Page  
Table 1. Typematic rate ................................................................................................................................................ 23  
Appendices  
Page  
Appendix A – Specifications.......................................................................................................................................... 40  
Appendix B – Parts and cables..................................................................................................................................... 40  
Appendix C - RackMount .............................................................................................................................................. 41  
Appendix D – Firmware upgrade .................................................................................................................................. 41  
Appendix E – IP Access Control ................................................................................................................................... 42  
Appendix F – VNC Viewer connection options ............................................................................................................. 44  
Appendix G – VNC viewer window options................................................................................................................... 47  
Appendix H – Browser viewer options .......................................................................................................................... 48  
Appendix I – Supported video modes........................................................................................................................... 49  
Appendix J – Hotkey sequence codes.......................................................................................................................... 50  
Appendix K – Video distance capability........................................................................................................................ 51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
Disclaimer  
While every precaution has been taken in the preparation of this manual, the manufacturer assumes no responsibility  
for errors or omissions. Neither does the manufacturer assume any liability for damages resulting from the use of the  
information contained herein. The manufacturer reserves the right to change the specifications, functions, or circuitry  
of the product without notice.  
The manufacturer cannot accept liability for damages due to misuse of the product or other circumstances outside  
the manufacturer’s control. The manufacturer will not be responsible for any loss, damage, or injury arising directly  
or indirectly from the use of this product.  
(See limited warranty)  
Introduction  
Thank you for choosing Rose Electronics UltraView Remote 2™ for your remote server access requirements. The  
UltraView Remote 2 is the result of Rose Electronics commitment to provide the best, most versatile, products for the  
business community. Now you can have access to all your servers locally or over IP. The multi-platform model  
allows you to connect different types of computers directly to the unit. If your system requires access to more than  
16 computers, the UltraView Remote 2 can easily be expanded to access up to 256 computers using our UltraView  
KVM switch as expansion units.  
Remote users have the ability of connecting to any computer over IP. This allows you to use, control, and monitor the  
remote computers directly from the unit, from your network workstation, or from any from anywhere in the world using  
the internet and a web browser.  
Installing the UltraView Remote 2 consists of  
configuring the unit to be compatible with  
your existing network, connecting  
the unit to local KVM station  
and to your network.  
Once connected you have  
full control of the selected  
computer provided your security  
profile permits it.  
The UltraView Remote 2 consists of an IP input module and a KVM switch module. Each module serves a unique  
purpose in access control and KVM switching control. The IP input module controls the accessibility, security, and  
state-of-the-art encryption to the unit. It can be accessed locally, remotely over your network, or from any workstation  
connected to the internet. All access methods require a user ID and password to gain access to the units IP input  
module. Access to the units IP input module from any remote user is via any supported web browser. The UltraView  
Remote 2 is further enhanced by the use of Real VNC that allows for the creation of ciphered user communications.  
Additionally, an optional user ID and password and other set-up parameters can be set-up to gain access and use  
the KVM switch module. This additional user ID can be set-up for each user needing access to the KVM switch  
module.  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Features  
.
Six models available:  
4-port model (PC or Multi-platform)  
8-port model (PC or multi-platform)  
16-port model (PC or multi-platform)  
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Supports PC or Multi-platform systems  
Solid-state embedded unit, has no disk drive for maximum reliability  
Remote application (Real VNC or Java applet) can be installed directly from the unit  
Local KVM port for configuring and direct access to the connected computers  
Connect to the unit directly, from a network workstation, or over IP using any supported web browser.  
Access remote computers by simple keyboard commands or an on-screen list of computers  
Access up to 256 computers in an expanded system  
Supports video resolution up to 1280 x 1024 @ 75hz  
Password security prevents unauthorized configuration and Unit access  
Remote access requires a user ID and password.  
IP lockout feature for incorrect login (IP address shown as “Blacklisted” in log file)  
All transmissions to and from a remote user are encrypted with the latest AES 128 bit encryption technology.  
Up to 16 remote user accounts can be set-up each with separate access permission levels.  
Scan function sequences through the connected computers at rates of 1 to 999 seconds  
Four different screen savers are available  
Rack mount kits available for 19”, 23”, or 24” racks  
Flash memory technology with free firmware upgrades which provide new features and support for the latest  
devices; available at ROSE.COM  
.
Made in the USA  
Package contents  
The package contents consist of the following:  
.
.
.
.
.
The UltraView Remote 2 unit  
RJ12 Serial Cable  
RJ to DB9 adapter  
Installation and operations manual CD  
Quick Start Guide  
Cables are usually ordered separately. If the package contents are not correct, contact Rose Electronics or your  
reseller so the problem can be quickly resolved.  
Compatibility  
Computers  
Monitors  
Industry standard PCs, Sun, Unix computers such as RS/6000, HP, SGI, DEC, and others.  
VGA  
Keyboards  
PC/Unix US, most foreign Qwerty keyboards, Korean and Japanese, keyboards with or  
without Windows keys (101, 102, 104, 105, 106, 109 keys), USB*, Sun*, Apple ADB*.  
Standard PS/2, PS/2 wheel  
Mouse  
Network  
Network  
workstations  
TCP/IP protocol  
Windows 98 or better PC connected to the network  
* Multi-platform models only  
2
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rose Electronics web site  
by Rose Electronics that are designed for data center applications, classroom environments, and many other access  
and switching applications.  
Product Registration  
Take advantage of the following when you register your Rose Electronics products online at  
http://www.rose.com/htm/online-registrationform.htm:  
.
.
.
.
.
Rose Standard Warranty Plus...  
Free Lifetime Firmware Updates  
Free Lifetime Technical Support  
30 Day Money Back Guarantee  
Priority “First-in-Line” Status for Tech Support  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
OVERVIEW  
System overview  
The UltraView Remote 2 is a versatile and powerful product that can extend the range of access to your computers  
from anywhere in the world. It is designed to provide seamless and trouble-free access from any workstation on your  
network or any remote user to any connected computer. You can connect to and control any of the connected  
computers by simple keyboard commands or an on-screen list of computers. Each computer can be assigned a  
unique name that makes sense for your system. Names like sales, production, and administration make it easy to  
recognize and connect to.  
Access control for the users can be set-up to provide access restrictions to the configuration and unit. The  
installation and configuration section explains all the features and functions of the UltraView Remote 2 and how to  
customize it to fit your business needs.  
The UltraView Remote 2 is designed with the highest regard for security. Remote access requires a user ID and  
password. All transmissions, to and from a remote workstation and UltraView Remote 2 uses the versatile and very  
secure RealVNC viewer and are encrypted with the latest encryption technology. Login, time-out, User ID and  
password add to the security of the system.  
Local workstation  
UltraView Remote  
Network  
Computers  
(4, 8, 16,  
or more)  
Local KVM  
Remote  
workstations  
(unlimited number)  
Typical connection diagram  
4
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODELS  
Connector  
Power  
Type  
IEC320  
DB25F  
DB25F  
RJ12F  
RJ45F  
CPU (4)  
KVM (1)  
RS232  
Network  
UPR-1R04UB/2 - UER-1R04UB/2  
Connector  
Power  
Type  
IEC320  
DB25F  
DB25F  
RJ12F  
RJ45F  
CPU (8)  
KVM (1)  
RS232  
Network  
UPR-1R08UB/2 - UER-1R08UB/2  
Connector  
Power  
Type  
IEC320  
DB25F  
DB25F  
RJ12F  
RJ45F  
CPU (16)  
KVM (1)  
RS232  
Network  
UPR-1R16UB/2 - UER-1R16UB/2  
Figure 1. UltraView Remote 2 Models  
Note: Model part numbers UPR-xxxxx are PC / Unix models  
UPE-xxxxx are Multi-platform models  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
UltraView Remote 2 Installation  
Installing the UltraView Remote 2 is a very easy process and should be performed by a designated administrator.  
The administrator will install, configure, and set-up user access profiles. A network administrator will need to assign  
an IP address to the unit (if needed) and set-up firewall and network access to the unit.  
The following installation procedure is a guide to properly install and configure the UltraView Remote 2. The  
following items are needed to install the UltraView Remote 2:  
1. A valid IP address to assign to the unit (if not using DHCP feature)  
2. VGA monitor  
3. PS/2 keyboard  
4. PS/2 mouse  
5. RJ45 network cable  
6. KVM Adapter cable (DB25M to PS/2F-PS/2F-HD15F)  
7. CPU Adapter cable(s) (DB25M to PS/2M-PS/2M-HD15M)  
Connecting the KVM station  
Connect the KVM stations PS/2 keyboard, video monitor and PS/2 mouse cables to the corresponding connectors on  
the KVM adapter cable as shown in Figure 2. The KVM station’s video monitor should be equal or better than any of  
the connected computers. Connect the DB25M end of the KVM cable to the KVM DB25F port on the rear panel of  
the UltraView Remote 2 unit.  
KVM Adapter Cable  
KVM Station  
Figure 2. Connecting a KVM  
6
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connecting the Computers / Servers  
Connect each computer to the UltraView Remote 2 using the appropriate CPU adapter cable designed to interface to  
the type of computer being connected (PS/2, Unix, SUN, DEC, Apple, etc). Connect the DB25M end of the CPU  
adapter cable to the desired DB25F CPU port on the rear panel of the unit. Connect the other end of the cable to the  
corresponding ports on the computer (keyboard, monitor, and mouse). Refer to Figure 3.  
CPU adapter  
cable(s)  
Remote  
computer  
connections  
Figure 3. Connecting Computers  
Connecting to the network  
Connect a network cable from the RJ45 connector on the rear panel of the UltraView Remote 2 and to your network  
(See Figure 4)  
Network connection  
Figure 4. Connecting to the Network  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cascading units  
If your system demands are greater than a single model can provide, you can cascade the UltraView Remote 2 to  
other UltraView Pro or ServeView Pro models. The total number of cascaded units that can be added is equal to the  
total number of CPU ports on the unit identified as the “Master” unit. If the “Master” UltraView Remote 2 unit has 8  
CPU ports, then 8 additional “Slave” units can be added, increasing the number of computers that can be accessed  
from 8 on a single unit to 64 in a cascaded system. A 16 CPU port model can expand to as many as 256 computers  
(16 CPU ports x 16 units). Figure 5 show a typical cascaded system using an UltraView Remote 2, 8 port master  
and two ServeView Pro 8 port models as slaves. The Master can have 6 computers connected directly to the unit  
and each Slave can have 8 computers connected to them giving a total computer access of 22.  
If you plan to expand your system, the unit designated as the “Master” must be configured to identify that there is an  
expanded system and how many expansion units have been added. This is explained in the “Switch configuration”  
section.  
Slave #1  
Slave #2  
Master  
Figure 5. Cascading units  
8
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
UNIT CONFIGURATION  
Configuring the UltraView Remote 2 IP Input module  
When you locally connect to the UltraView Remote 2 unit for the first time the Unit and Network must be configured.  
Follow the recommended procedure below to configure all models:  
a. Make all cable connections to the KVM station, network, and computers  
b. Make sure power is applied to all devices (Computer, UltraView Remote 2, and Monitor).  
c. Make sure a computer is connected to CPU port #1 and that computer is powered on.  
If no computer is connected to port #1, the OSD menu screens may not sync.  
d. With power applied, a standard login screen will display on the KVM monitor  
e. Login on to the unit using the default user ID, admin and no password  
f. After a successful login, the remote computer’s video will display on the KVM monitor.  
g. Press the CTRL + ALT + C keys simultaneously to display the configuration menu options  
as shown below: (Unit connection screen may display after initial connection is made)  
Figure 6. Configuration Menu  
Select “Unit Configuration” and the below screen will display  
Figure 7. Unit Configuration Menu  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Keyboard Layout  
Using the left and right arrow keys, select the keyboard type expected from the host computers.  
Admin password  
Enter an administrator password of at least six characters that has a mix of letters and numerals. The background  
color provides an indication of password suitability. It is initially red to indicate that the password is not sufficient.  
When a password with reasonable strength has been entered it changes to blue.  
Time and Date  
Set the time and date to the correct values. Use the 24 hour base inputs. All entries in the activity log are time  
stamped using this information.  
Encryption  
Arrange this setting according to your security requirements.  
When all items have been updated, click on “Next” to configure the network information. The network information  
entered (IP Address, Net Mask, and Gateway) must be compatible with the network UltraView Remote 2 will be  
connected to.  
Figure 8. Network Configuration Menu  
MAC address  
Media Access Control address – this is the unique and unchangeable code that was hard coded within your  
UltraView Remote 2 unit when it was built. It consists of two 6-digit hexadecimal (base 16) numbers separated by  
colons. A section of the MAC address identifies the manufacturer, while the remainder is effectively the unique  
electronic serial number of your particular unit  
Use DHCP/IP address/Net Mask/Gateway/VNC port/HTTP Port  
1. You need to either set the DHCP option to ‘Yes’ or manually enter a valid IP address, Net mask and Gateway.  
If you set the option to use DHCP, remote users must be informed of the IP address assigned so they can  
remotely access the unit.  
2. Change the IP Address to the IP address assigned to the unit by your network administrator  
that is compatible with your network.  
3. Change the Net Mask and Gateway addresses if needed.  
4. The VNC and HTTP ports should remain set to 5900 and 80, respectively, unless they clash with an existing  
setup within the network.  
5. When all network information has been entered, click on “Next” to calculate a “Secure Key”.  
10  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Screen #3 is a secure keys screen that will display after the network information has been entered.  
Figure 9. Secure Keys Encryption  
This screen uses mouse movements and keyboard inputs to create random data. This unpredictable information is  
then combined with several other factors to develop the basis of the encryption keys that are used to establish  
secure remote links.  
With every mouse move and key press the single dash will move across the progression bar (unless the same key is  
pressed repeatedly). Periodically, a new star character will be added to the bar as the random data are accepted as  
part of the new encryption key. When the bar is full, the final encryption keys for your UltraView Remote 2 will be  
created – this process takes roughly 30 to 40 seconds.  
Once the secure key has been calculated, the UltraView Remote 2 will restart and present a standard logon screen  
as shown below.  
Figure 10. Logon screen  
At this stage the username is still ‘admin’ but the password will be whatever you entered on the Unit Configuration  
setup screen. Once the username and password has been validated, the screen should now show the host computer  
screen.  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To view the menu options press <CTRL> <ALT> <C>.  
(if the standard hotkeys were altered on the Configure Unit screen, use the new hotkeys plus C)  
Logoff  
Select this option to close your current session and display the screensaver.  
Restore mouse functions  
Select this tab to revive a mouse that has ceased to function correctly. The UltraView Remote 2 provides a feature to  
reinstate PS/2 mouse communications. (Does not apply if using a USB mouse.)  
There are two main types of data formats used by current PC mice; ‘PS/2’ format and the more recent ‘IntelliMouse®’  
format introduced by Microsoft. These use slightly different data arrangements and it is important to know which type  
was being used before you hot-plugged the computer to the UltraView Remote 2. The previous setting depends both  
on the type of mouse and the type of driver, as various combinations of PS/2 and IntelliMouse are possible. Using  
the incorrect restore function may produce unpredictable results and require the computer to be re-booted.  
Using a keyboard and monitor directly connected to the  
UltraView Remote 2, log on and then press the hotkey  
sequence <Ctrl> <Alt> <C> to view the options menu.  
1. Select the ‘Restore mouse functions’ option to  
display:  
2. Select one of the following options:  
3. Restore Standard Mouse – if PS/2 mode is required,  
or Restore IntelliMouse – if IntelliMouse mode is  
required.  
4. Select “Back” to return to the Control menu.  
Configuration  
Select the “Configuration” tab to gain access to the Unit and Network configuration menus. You can also reset the  
UltraView Remote 2 to its initial state.  
Access mode  
Allows you to choose between the Shared mode (where all other logged on users can see your operations) and the  
Private mode (where the screens of all other users are blanked).  
Host  
Indicates the currently selected host computer and allows you to select others. This item will be blank unless host  
details have been set-up.  
Return to host  
Quits the menu and returns to the host screen.  
12  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connecting Remotely  
With the Unit and the Network configured properly, start a web browser like IE or Netscape from any workstation  
connected to the same network your UltraView Remote 2 is connected to. Type in the UltraView Remote 2’s  
below screen. There may be initial login and connect screens displayed.  
(NOTE: See Appendix F for additional VNC Viewer options)  
Click on the “Connect using built-in VNC viewer” option and the UltraView Remote 2 will install a temporary Java  
applet on the requesting computer and then display the connected computer’s video in the browser’s VNC viewer  
window. In the upper right corner of the window is a “Configure” tab. Click on this tab to display the remote  
configuration option menu as shown below.  
Remote Configuration  
Connect to the UltraView Remote 2 unit from any network workstation. When connected, click on the “Configure” tab  
in the upper right corner of the display. The below configuration menu will display.  
Clicking on the Configure tab  
Displays the configuration window  
Figure 11. Remote Configuration Menu  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(Following describes each of the Configuration Tabs.  
Allows you to create and manage up to sixteen separate user accounts, each with  
User Accounts  
separate access permissions. Account #1 is the admin account. Enter User name,  
password. Tick/un-tick the Local and Remote options that are appropriate to the user.  
Allows you to modify unit settings within the UltraView Remote 2. You can define the  
keyboard, set-up the admin account, assign a name to the unit, screensaver time and  
encryption options  
Unit Configuration  
Time & Date  
Configuration  
Set the time and date, this time stamps the log files  
Configures the network IP, network mask, gateway, VNC port, HTTP port. You can  
alter any of the existing network settings plus you can set-up the IP access control  
feature that lets you specifically include or exclude certain addresses or networks  
Network Configuration  
Host Configuration  
Allows configuration of various details for each host system connected to UltraView  
Remote 2. 128 entries max, Add host names, Users, Hotkey, and power control  
sequence.  
Logging and Status  
LDAP Configuration  
Return to Host  
Provides various details about the UltraView Remote 2 activity  
Configures unit for LDAP  
Exit the configuration menu system and return to the host computer  
Following is an explanation and examples of each of the configuration items:  
User Accounts  
Selecting user accounts will display the following menu.  
The first of the sixteen accounts is the admin account and is the only account with access rights to the configuration  
menus. The user name and access rights are fixed for the admin account. The only change possible for this account  
is the password.  
There are fifteen user account positions.  
To create a new account  
1
Enter the required User Name to activate that position (the Password and access tick box positions will  
become editable).  
2
3
4
Optionally enter a password for the user account.  
Tick/un-tick the Local, Remote, and Auto Logon options that are appropriate to the user.  
Click the Save button to register your changes.  
14  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Name  
All user names must consist of lower case characters or numbers only. No symbols or upper case characters are  
permissible. The user name can be between 1 and 16 characters in length.  
Password  
Passwords are case sensitive and can include certain keyboard symbols. The password can be between 1 and 16  
characters in length. The password background remains shaded in amber while the UltraView Remote 2 considers  
your entered password to be too easy to guess. A suitable password is best constructed using a mixture of more  
than 6 letters, numbers and punctuation characters.  
Local  
When ticked, the selected user can gain access using the local KVM station directly connected to the UltraView  
Remote 2.  
Remote  
When ticked, the selected user can gain access via an IP network link, such as a local intranet or the wider Internet  
(depending on how the UltraView Remote 2 is connected and the network access is configured.).  
Auto-Logon  
When ticked and power is applied to the unit, the user is automatically logged on. When not is use, the user should  
logoff.  
Unit Configuration  
The ‘Unit Configuration “option tab will display the following menu.  
Hardware Version  
Indicates the version of the electronic circuitry within the UltraView Remote 2 unit.  
Firmware Version  
Indicates the version of the hardwired software within the UltraView Remote 2 flash memory. This may be updated  
using the flash upgrade procedure.  
Host Keyboard Layout  
Use the arrow buttons to match the keyboard layout expected by the host system.  
Admin Password  
Enter the password that will be used to gain administrator access to the UltraView Remote 2. There can only be one  
admin user and only that user is given access to the configuration menus.  
Unit Name  
The name entered here will be displayed on the local menus and the remote VNC viewer/browser windows.  
Local Hot Key Sequence  
Use the arrow buttons to select an appropriate hot key sequence for the locally connected keyboard. This sequence  
is used in combination with other key presses to access the on-screen menus and to change between hosts. The  
options are: Ctrl+Alt (default), Ctrl+Shift, Alt+Shift, Alt Gr, Left + Right Alt, Left Ctrl + Alt or Right Ctrl + Alt.  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Screensaver Timeout  
Use the arrow keys to select an appropriate period of inactivity before a screensaver is displayed and the user is  
logged out. This setting applies to local users only and once the screensaver is displayed, for security purposes the  
user is required to log in again. The timeout period can be selected between 5 minutes and 1 day (24 hours), it  
cannot be disabled.  
Menu Bar Toggle Hot Key  
Use the left or right arrow keys to choose the hot key to turn on or off the menu bar.  
(NOTE: DO NOT assign a hot key value that will conflict with other hot key assignments. The KVM switch  
module uses hotkeys to quickly perform an operation. Make sure the hot key assigned to toggle the menu  
bar is unique)  
Encryption  
Three encryption options are available; Always on, Prefer off, Prefer on. The one to choose depends on the specific  
details of your installation. The use of encryption imposes a slight performance overhead of roughly 10% but is highly  
secure against third party intrusion.  
Encryption settings  
The Unit configuration page offers three encryption settings:  
Always on - This setting will force all viewers to use encryption. Note: This setting will preclude any VNC  
viewer versions that do not support encryption.  
Prefer off - This setting does not enforce encryption unless a viewer specifically requests it. If a viewer has its  
‘Let server choose’ setting, then an un-encrypted link will be set up.  
Prefer on - This setting generally enforces encryption unless an earlier viewer version is unable to support it,  
in which case the link will be un-encrypted. If a viewer has its ‘Let server choose’ setting, then the link will be  
encrypted.  
The “Advanced Configuration” tab will display advanced options that generally do not need modifying.  
Force VNC protocol 3.3  
IMPORTANT: The use of this option is not recommended. VNC protocol 3.3 is a legacy version that does not offer  
any encryption.  
Idle timeout  
Determines the period of inactivity on a remote connection before the user is logged out. The idle timeout period can  
be set to any time span, expressed in minutes. Note: The Screensaver option serves a similar purpose for local  
connections. A value of 0 will disable the timeout.  
Protocol timeout  
Sets the time period by which responses should have been received to outgoing data packets. If the stated period is  
exceeded, then a connection is considered lost and terminated.  
16  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Background refresh rate  
Use the arrow keys to alter the refresh rate for screen images via remote links. This allows you to tailor the screen  
refresh to suit the network connection speeds. The options are: Slow, Medium, Fast or Disabled. When the disabled  
option is selected, the remote users will need to manually refresh the screen.  
Note: When a low connection speed is detected, the background refresh is automatically disabled, regardless of the  
settings of this option.  
Mouse Latency Allowance  
This option is used during calibration to account for latency delays (caused as signals pass through a device)  
introduced by some KVM switches. During calibration, the UltraView Remote 2 waits for 40ms after each mouse  
movement before sampling the next. If a KVM device adds a significant delay to the flow of data, the calibration  
process can be lengthened or may fail entirely. The value entered here is added to (or subtracted from) the default  
40ms sampling time.  
Note: You can enter negative values (down to -40) in order to speed up the calibration process when using fast KVM  
switches. Use this option with caution as it can adversely affect the calibration process.  
Mouse rate  
Defines the rate at which mouse movement data are transmitted to the system. The default option is 20ms, which  
equates to 50 mouse events per second. This default rate can prove too fast when passed through certain connected  
KVM switches. In such cases, data are discarded causing the local and remote mouse pointers to drift apart. If this  
effect is encountered, increase the mouse rate to around 30ms (data are then sent at a slower rate of 33 times per  
second).  
Single Mouse Mode Mouse Switch  
This option allows you to select the mouse button combination that can be used to exit from single mouse mode  
(when active). Options are: Disabled, Middle+Right Button, Middle+Left Button.  
Behavior for admin connections when limit reached  
Use the arrow keys to modify the action taken when the number of admin connections is reached. The options are:  
Replace oldest connection  
Replace newest connection  
Don’t replace  
Use Quick Mouse Calibration  
When this option is checked, the mouse calibration procedure is performed quickly. If the mouse still does not react  
or follow, perform the complete “Mouse and Video” calibration.  
Behavior for admin connections when limit reached  
Use the arrow keys to modify the action taken when the number of admin connections is reached. The options are:  
Replace oldest connection  
Replace newest connection  
Don’t replace  
Use VESA GTF  
When ticked, the VESA Generalized Timing Formula will be used to help determine the correct input video resolution  
and timing details. See Appendix I for a list of all supported video modes.  
Enable Virtual Media  
The virtual media function is not available on this model.  
Upgrade Firmware  
The Upgrade Firmware tab allows you to easily update the firmware when changes and enhancements have been  
made. Click on this tab and follow the instructions to upgrade the firmware on UltraView Remote 2.  
Time and Date Configuration  
Use the left and right arrow keys to select the correct time and date. The time entry uses the 24 hour clock notation.  
The internal real time clock will continue to run for roughly one week without power to the UltraView Remote 2, after  
that it will be lost and require resetting. Use the up and down arrow keys to move between each of the sections within  
the time and date entries.  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Network configuration  
This page allows you to configure the various aspects of the IP port and its relationship with the local network.  
MAC address  
Media Access Control address – this is the unique and unchangeable code that was hard coded within your  
UltraView Remote 2 unit when it was built. It consists of two 6-digit hexadecimal (base 16) numbers separated by  
colons. A section of the MAC address identifies the manufacturer, while the remainder is effectively the unique  
electronic serial number of your particular unit.  
Use DHCP  
DHCP is an acronym for ‘Dynamic Host Configuration Protocol’. Its function is particularly useful when connecting to  
medium size or larger networks. When this option is selected, your UltraView Remote 2 will attempt to locate a  
DHCP server on the network. If such a server is located, it will supply three things to the UltraView Remote 2: an IP  
address, an IP network mask (also known as a Subnet mask) and a Gateway address. These are not usually granted  
permanently, but on a ‘lease’ basis for a fixed amount of time or for as long as the UltraView Remote 2 remains  
connected and switched on. Remote users must be informed of this IP address in order for them to successfully  
connect to the UltraView Remote 2 unit.  
IP Address  
This is the identity of the UltraView Remote 2 within a network. The IP address can be altered to suit the network it is  
connected on. It can either be entered manually or configured automatically using the DHCP option. When the DHCP  
option is enabled, this entry is grayed out.  
IP Network Mask  
Also often called the subnet-mask, this value is used alongside the IP address to help define a smaller collection (or  
subnet) of devices on a network. In this way a distinction is made between locally connected devices and ones that  
are reachable elsewhere, such as on the wider Internet. This process helps to reduce overall traffic on the network  
and hence speed up connections in general.  
IP Gateway  
This is the address of the device that links the local network the UltraView Remote 2 is connected to another  
network such as the wider Internet. Usually the actual gateway is a network switch or router and it will be used  
whenever a required address lies outside the current network.  
VNC Port  
This is the logical link through which communications with a remote VNC viewer will be channeled. The default  
setting is 5900 which is a widely recognized port number for use by VNC software. However, in certain  
circumstances it may be advantageous to alter this number.  
18  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HTTP Port  
This is the logical link that communications with a remote web browser will be channeled. The default setting of 80 is  
an established standard for web (HTTP – HyperText Transfer Protocol) traffic though this can be changed to suit  
your local network requirements.  
IP Access Control  
This section allows you to optionally specify ranges of addresses which will or will not be granted access to the  
UltraView Remote 2. If this option is left unchanged, then the default entry of ‘+0.0.0.0/0.0.0.0’ ensures that access  
from all IP addresses will be permitted. If this feature is needed, please see Appendix E for a detailed explanation of  
IP access control.  
Host Configuration  
The Host Configuration menu allows you to configure various details for each of the host systems that may be  
connected to the UltraView Remote 2. Each of the 128 entries can be configured with a name, the permitted users,  
and the hot key combinations to switch to it.  
Click on the “Erase Host Configuration” tab to remove  
all host entries if needed.  
Check the box “Add entry for unrecognized host” to  
add any system connected to that is not specified in  
the Host list. Verify these added hosts for the correct  
Hot key sequence and user permission. Connecting  
to complex cascaded systems should be verified.  
It is recommended that the naming and hot key  
assignments for each Host Configuration entry match  
the CPU port configuration of the UltraView Remote 2.  
Entry #1 - Name and hot key defined to switch to  
CPU port #1, Entry #2 for CPU port #2, etc.  
Examples of Hot key sequences for switching to a  
given port are shown below.  
To add a new entry to the Host Configuration, click (highlight) one of the host entries to bring up the host  
configuration dialog box.  
Select each item (1 – 128) as needed and enter the Name, Users,  
Hotkey / KVM port keyboard sequence, and power control ON and  
Off key sequences.  
Click OK after each item has been entered.  
Name  
Enter the name that will be displayed in the viewer window when you click the Host button.  
Users  
Select the users that will be permitted to connect to this host. Either enter * to allow all users or a list of users  
separated by commas (e.g. sales, admin, eng, david).  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hotkey / KVM Port  
Declare the hot key sequence, or Remote Port Direct address that will cause the KVM switch module to link with the  
required host system. Remote Port Direct addresses must be entered within square brackets. To set-up the hotkey  
values used to switch to a given CPU port, the following information is used to create the hot key sequence:  
+
means press down the key that follows  
means release the key that follows  
+– means press down and release the key that follows  
To switch to CPU port #1, the Hotkey / KVM port sequence would be +-Ctrl+-1+-Enter, to switch to CPU port #8, the  
sequence would be +-Ctrl+-8+-Enter, the sequence to switch to CPU port #15 would be +-Ctrl+-1+-5+-Enter. A list of  
the valid hotkey codes are given in Appendix J.  
Logging and Status  
This screen provides various details about the user activity on the UltraView Remote 2 .  
Note: The log has a maximum capacity of 1000 event lines. After 1000 entries, the oldest entries are overwritten. If  
log data are important to your installation, ensure a regular backup procedure or use the Syslog Server IP Address  
option to send log information automatically to another system.  
The first three (3) columns show the date the event  
occurred.  
The next column is the time the event occurred.  
The last column describes the type of event with the  
users name and the access method.  
The “Clear log” tab will clear all entries in the log  
The “Refresh” tab will refresh the log list  
The “Syslog Server IP Address field is an optional  
field where you can enter an IP address to send the  
status log.  
The “Save” tab will save the log file  
The “Cancel” tab will exit the log menu and return to  
the main menu  
To copy and paste the log  
You can copy the information listed within the log and paste it into another application. While viewing the log screen,  
press Ctrl and C, to copy the data into the clipboard. Start a text application (i.e. Word, WordPad, Notepad) press  
Ctrl and V, or right mouse click and ‘Paste’.  
This basically covers the configuration of the input module and allows user access to the unit. Following is the  
additional KVM switch module configuration. Some configurations are needed to assure proper functionality and  
other configurations are optional.  
20  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
KVM Switch Module Configuration  
Connect to the unit directly from the local KVM station. A computer must be connected to CPU port #1 and powered  
on. Using the local keyboard, press and release the Ctrl key, then within 2 seconds press the F12 key. The press  
and release of the Ctrl key notifies the KVM Switch module that the next command issued within 2 seconds is a  
command for the KVM Switch, not a connected computer. The F12 key will invoke the KVM switch modules OSD  
main menu shown below.  
Figure 12. Main configuration menu (Ctrl + F12)  
From this menu, you can configure the system, configure the connected computers, the appearance or overlay of the  
displayed menus, and assign unique passwords for accessing the configuration menus and a password for  
accessing the connected computers. Use the up/down arrow keys to select which section menu to configure and  
press enter.  
From the Main configuration menu, use the up or down arrow keys to select (highlight) “Configure system” and press  
enter. The Configure system menu will display (Figure 13 ).  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configure System  
Figure 13. Configure system menu  
To configure the local keyboard or mouse type, use the up/down arrow keys and select keyboard or mouse and  
press enter. A display box will appear listing the choices for the keyboard or mouse. Use the up/down arrow keys to  
select the correct keyboard or mouse and press enter. The select choices are:  
Keyboard choices  
101/102  
Mouse choices  
PS/2 or PS/2 wheel  
Serial 2-button (N/A)  
Serial 3-button (N/A)  
NOTE: A serial mouse can not  
be connected to the locally,  
only a PS/2 type mouse  
104/105  
Expansion  
If your system consists of cascaded units, the expansion section of the Configure System menu must be properly  
configured to provide the needed information to manage the slave units.  
It is recommended that all slave units have the same number of CPU ports as the “Master” unit. To change the  
“Maximum computers”, “Expansion width”, and “Expansion units”, use the up/down arrow keys and select the item  
and press enter. An input box will display for a new value. (See figure 5)  
Maximum computers  
This setting configures the total number of computers that are connected and provides a wrap around value for  
scanning. Switching commands are validated against this value for a valid port number. The “Maximum computers”  
value is the Expansion width value times the number of slave units plus the CPU ports on the master unit that are not  
used for expansion. Enter the number of connected computers and press enter. Valid entries are 2 to 256.  
Expansion width  
The “Expansion width” setting determines how many computers are connected to a slave unit. If the slave units are  
4 port units, the width value would be 4. If they are 8 port units, the expansion width value would be 8. If the  
expansion units are a mixture of 4, 8, and/or 16 port units, the “Expansion width” value is the number of CPU ports  
on the expansion unit with the greatest number of ports.  
Expansion units  
The “Expansion units” setting is the number of slave units that are connected to the master unit. This value  
determines which computer number is associated with which physical connector.  
If no expansion units are used, this number should be set to zero.  
22  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Scan settings  
The scan settings section determines the amount of time in seconds that a computer’s video is displayed before  
automatically switching to the next sequential computer. The scan mode can be turned on or off and set to  
automatically scan the computers when the UltraView is powered up.  
Scan time (seconds)  
To change the scan time, highlight “Scan time” and press enter. An input box will display for a new value. Enter the  
new scan time in seconds and press enter. Valid entries are 1 to 999.  
Scan mode  
This value turns scanning on or off. To change this value, select “Scan mode” and press enter. An input box will  
appear. Select “On” or “Off” and hit enter.  
Power on scan  
Setting this value to “On” will enable scanning when the UltraView is powered on. To change this value, select  
“Power on scan” and hit enter. Use the up/down arrow keys to select “OFF” or “ON” and press enter.  
Keyboard settings  
The keyboard setting section of the configure system menu is used to change the typematic rate and delay for PC  
keyboards and also to set the language type for Sun keyboards.  
Rate (keys/sec)  
To change the rate value, highlight “Rate (keys/sec)” and press enter. An input box will appear. Choose the rate  
value from Table 1 that represents the Rate keys/sec needed and press enter.  
Rate  
Keys/  
Sec.  
Rate  
Value  
Rate  
Keys/  
Sec.  
Rate  
Value Keys/  
Sec.  
Rate  
Rate  
Value Keys/  
Sec  
Rate  
Rate  
Value  
30.0  
26.7  
24.0  
21.8  
20.0  
18.5  
17.1  
16.0  
31  
30  
29  
28  
27  
26  
25  
24  
15.0  
13.3  
12.0  
10.9  
10.0  
9.2  
23  
22  
21  
20  
19  
18  
17  
16  
7.5  
6.7  
6.0  
5.5  
5.0  
4.6  
4.3  
4.0  
15  
14  
13  
12  
11  
10  
9
3.7  
3.3  
3.0  
2.7  
2.5  
2.3  
2.1  
2.0  
7
6
5
4
3
2
1
0
8.6  
8.0  
8
Table 1. Typematic rate  
Delay  
This setting is for PC keyboards only. It is used to adjust how long, after a key is depressed and held, that key starts  
to repeat. To change the delay value, select “Delay” and press enter. A list box will display showing the choices  
available. Use the up/down arrow keys to select the delay rate wanted and press enter.  
The choices are:  
Slow (1 second)  
Medium (750 ms.)  
Fast (500 ms.)  
Fastest (250 ms.)  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Sun Language  
If the Sun keyboard type you are using is not a US Sun keyboard, the language can be changed to the correct  
language keyboard. To change the language type, select “Sun Language” and press enter. A list box will display  
showing the language choices available. Use the up/down arrow keys to select the correct Sun Keyboard language  
and press enter.  
The choices are:  
US  
Neth/Dutch  
Norwegian  
Portuguese  
Spanish  
Swed/Finn  
SWFrench  
SWGerman  
UK  
Korean  
Taiwan  
Japan  
US Unix  
French  
Danish  
German  
Italian  
FrCanadian  
Configure computers  
The “Configure computer” menu allows you to assign unique names to each computer and change the keyboard and  
mouse type for each connected computer. Use the page up/down keys if there are more than 16 computers  
connected in the system. (See Figure 14)  
Figure 14. Configure computers  
Computer name  
The name of the connected computers can be changed from computer x to any name up to 16 valid ASCII  
characters. Assigning a unique name to each computer gives you the ability to know what computer you are  
connecting to without having to remember or use a cross-reference list.  
To change the computer name, select the “Computer name” to change and press enter. An input box will display.  
Enter the new computer name and press enter. It is recommended that the computer names entered are the same  
as the names entered in the Host configuration section of the Input Module configuration. To change a computers  
keyboard and/or mouse, use the up/down arrow keys to select (highlight) which computer to change the keyboard or  
mouse. Use the left/right arrow keys to select either the keyboard or mouse to change and press enter.  
A window will appear listing the keyboard or mouse types available. Use the up/down arrow keys and select the  
correct keyboard or mouse type needed for the selected computer and press enter. The keyboard or mouse type will  
change to the new type.  
USB keyboards for PC and Sun computers are fully supported.  
Save the changes when finished configuring each computer.  
The keyboard and mouse selections for the connected computers are:  
24  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Keyboard choices  
PC1  
Mouse choices  
PS/2  
PC2  
PC3  
USB-PC  
USB-Sun  
Apple*  
Sun*  
PS/2 wheel  
Serial 2-button  
Serial 3-button  
* Available on multi-platform models only.  
Configure overlay  
The “Configure overlay” menu is used to configure the color of the menus, the resolution of the video when no  
computer video is present, the screen saver type and time, the computer select window appearance, and the  
displayed computer label. The “Configure overlay” menu is accessed by first calling up the main configuration menu  
(<Ctrl>, F12), and then selecting “Configure overlay” and pressing enter. See Figure 15.  
Figure 15. Configure overlay  
Miscellaneous  
Color scheme  
The default setting is Aquarium. To change this, select “Color scheme” and press enter. A selection box will appear  
listing the 4 choices. Use the arrow keys to select a scheme and press enter. The choices are:  
Aquarium - cyan, magenta, white, and blue  
Tuxedo - black, red, and white  
Night sky - blue, black, and white  
Forest - green, black, cyan, and blue  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Resolution  
Use this configuration to set the resolution for the KVM stations video if no computer video is present. To change the  
setting, select “Resolution” and press enter. A selection box will appear listing the choices.  
The default setting is PC2, 640 x 480 @ 60Hz.  
DO NOT select a setting that the KVM monitor cannot support  
The resolution choices are:  
PC1  
PC2  
PC3  
MAC1*  
1640 x 480 @ 60Hz  
640 x 480 @ 72Hz  
640 x 480 @ 75Hz  
640 x 480 @ 67Hz  
MAC2* 832 x 624 @ 75HZ  
SUN1* 1152 x 900 @ 66Hz  
SUN2* 1152 x 900 @ 76Hz  
HV*  
CS*  
640 x 480 @ 66Hz  
1152 x 900 @ 66Hz  
* Available on multi-platform models only.  
Screen saver  
This feature activates a screen saver when there is no keyboard or mouse activity for a specified time period. To  
change the setting, select “Screen saver” and press enter. A selection box will appear listing the 4 types of screen  
savers that are available. Use the up/down arrow keys to select a new screen saver and press enter.  
The default screen saver is Fireflies.  
The choices are:  
Black screen  
Fireflies  
Weaving  
Bounce  
Screen saver time (seconds)  
This sets the time the screen saver activates when no keyboard or mouse activity is present. To change the time,  
select the item and press enter. An input box will display to enter a new value. Valid entries are 0 to 999 seconds.  
A value of 0 disables the screen saver function.  
Computer select window  
The “Computer select window” section allows you to change the background and text colors of the computer select  
window, and the text position on the screen.  
Use the up/down arrow keys to select the item to configure and press enter.  
DO NOT set the background and text colors the same.  
26  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Background color  
To change the background color, select “Background color” and press enter. A color selection box will display  
showing the available background colors. Use the arrow keys to select either a solid or transparent color and press  
enter.  
The default background color is Transparent blue.  
The color choices are:  
Solid colors  
Black  
Red  
Transparent colors  
Clear  
Red  
Green  
Yellow  
Blue  
Green  
Yellow  
Blue  
Magenta  
Cyan  
White  
Magenta  
Cyan  
White  
Text color  
To change the text color, select it and press enter. A color selection box will display showing the available text colors.  
Use the arrow keys to select either a solid or transparent color and press enter.  
The default text color is white. The color choices are the same as the background selections.  
Computer label  
The “Computer label” section allows you to customize the display of the computer label. The colors, position, fade  
out time, font and whether the computer number is displayed.  
Background color  
To change the background color, select “Background color” and press enter. A color selection box will display  
showing the available background colors. Use the arrow keys to select either a solid or transparent color and press  
enter. The default background color is Transparent blue. The choices are the same as the background colors for the  
computer select window.  
Text color  
To change the text color, select it and press enter. A color selection box will display showing the available text colors.  
Use the arrow keys to select either a solid or transparent color and press enter.  
The default text color is white. The choices are the same as the background colors for the computer select window  
Position  
This item sets the position of the computer label window on the display screen. This position is maintained at all  
screen resolutions.  
To change the position, select “Position” and press enter. The overlay page will disappear and a label box will  
display. Use the arrow keys to move the label box anywhere on the screen. Press enter when the desired position is  
reached. The screen position values are entered automatically into the x (horizontal) and y (vertical) fields. Setting  
the position off the edge of the screen may cause an out of sync image.  
Valid entries are 0 – 64 (horizontal) and 0 – 99 (vertical).  
Show computer number  
This sets whether the computer number and computer name are displayed on the KVM stations monitor when a  
computer is selected. Select this item and press enter. A YES/NO box will display. Use the up/down arrow keys  
and select either YES or NO and press enter.  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fade out (seconds)  
This controls how long the computer label displays before disappearing. A value of zero (0) disables this function  
and the label will not be displayed. A value of 255 causes the computer label to always be displayed. To change  
this value, select it and press enter. An input box will display for a new value. Enter the value wanted between 0 and  
255 and press enter.  
(<Ctrl> D, <Enter> will display the label at any time)  
Font  
This item sets the font type for the computer label. To change the font, select “Font” and press enter. Use the  
up/down arrow keys to select a new font type and press enter.  
The font choices are:  
8 x 16 modern  
8 x 16 classic  
16 x 24 modern  
16 x 24 classic  
16 x 32 modern  
16 x 32 classic  
The actual size of the font will vary  
depending on the resolution of the video.  
As the resolution increases, the fonts  
become smaller.  
The modern font is sans-serif, the classic is  
similar to Times.  
28  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Security  
The Security set-up provides an additional administrator and user access control system that is independent from the  
UltraView Remote 2 IP Access Module’s security system. The “Configure security” menu allows for setting a  
configuration password and an access password that apply to both a local user and a remote network user. The  
configuration password restricts access to the KVM switch module configuration menus and the access password  
limits access to the connected computers.  
Figure 16. Configure security  
Configuration password  
To assign a “Configuration password”, select it from the “Configure security” menu and press enter. An input box will  
appear. Type in the desired configuration password (case sensitive, 8 chars max) and press enter. A confirmation  
box will display, re-type the password and press enter. When the password is saved, the next time the configuration  
menu is called up (<Ctrl>, F12), this password must be entered.  
Access password  
This feature is used to restrict unauthorized access to the connected computers. To assign an access password,  
select it from the menu and press enter. Enter this password the same way as you entered the configuration  
password. When the UltraView is powered on or if you disconnect from a computer, a login box will display  
requesting the access password.  
Access time (minutes)  
The access time setting is used to automatically log out of a switch after the set time period. When there is no  
keyboard or mouse activity for this time setting, the user is automatically logged out. To change this value, select it  
from the menu and hit enter. An input box will display for a new access time value. Enter the new time in minutes  
and hit enter. Valid times are 1 to 999 minutes.  
Logging off the system  
To log off the system and lock the keyboard enter <Ctrl> and the L key to disconnect from the switch. To gain  
access to the connected computers, an access password must be entered if one has been assigned.  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
Remote System Operation  
Connecting using a web browser  
Connecting to the UltraView Remote 2 from a network location or over the internet can be done two ways; using the  
Built-in Java VNC Viewer or Downloading Windows VNC Viewer from the unit and installing it on the remote  
computer. It is recommended that the Windows VNC viewer be downloaded from the unit and installed on the  
remote computer. The VNC viewer is more robust than the Java applet and has more functionality and features than  
the Java applet. If you experience problems using the Java applet, switch to the VNC viewer application.  
To connect to the UltraView Remote 2 from any workstation, start a web browser and enter the assigned IP address  
for the unit in the URL field of the browser (Example http://192.168.0.44). The UltraView Remote 2 will respond with  
the below three options displayed in the browser’s window.  
The first time a connection to the UltraView Remote 2 is made, it is recommended that you download the Windows  
VNC viewer from the unit, save it and run the VNC viewer to connect to the unit directly. Some operating systems  
may request permission to run or save the program. Save the program to the location wanted and create a desktop  
ICON for the program. The next time the RealVNC viewer is needed, just click on the desktop ICON to connect.  
After the installation is complete, run the VNC viewer program and the VNC Viewer Connection Details window will  
display. Make sure that the Server IP address is correct and the port number is 5900. If the port number was  
changed during the unit configuration procedure, this number will match that VNC port configuration number.  
Click on “OK” to enter  
your Username and  
Password  
Click on the OK tab and VNC Authentication box will display. Enter the Username and password and click OK.  
Upon validation, the remote connected computer’s video will display.  
NOTE: If the username or password is entered incorrectly five consecutive times, the remote user station’s IP  
address is locked out and remote access is denied. The lockout of an IP address will show up in the log as  
IP address “Blacklisted”. (See the troubleshooting section for the procedure to unlock the IP address)  
Click on the OK tab and the remote connected computer’s video will display.  
Viewer encryption settings  
The web browser viewers and VNC viewers (of level 4.0b5S or higher) offer four encryption settings:  
Always on - This setting will ensure that the link is encrypted, regardless of UltraView Remote 2 encryption  
setting.  
Let server choose - This setting will follow the configuration of the UltraView Remote 2. If the UltraView Remote 2  
has ‘Always on’ or ‘Prefer on’ set, then the link will be encrypted. If the ‘Prefer off’ setting is selected at the  
UltraView Remote 2, then the link will not be encrypted.  
Prefer off - This setting will configure an un-encrypted link if the UltraView Remote 2 will allow it, otherwise it will  
be encrypted.  
Prefer on - If the UltraView Remote 2 allows it, this setting will configure an encrypted link, otherwise it will be un-  
encrypted.  
30  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VNC Viewer Toolbar  
Figure 17 shows the VNC Viewer toolbar and an explanation of each toolbar tab. The VNC viewer uses a two mouse  
cursor technique to identify if you are working on the VNC Viewer or the remote PC’s desktop. The local cursor is  
the dot and the arrow cursor is the host computers desktop. When you move the cursor, the arrow cursor will follow  
the dot cursor. When you move the cursors off of the host computer’s desktop onto the remote computer’s desktop,  
a single arrow cursor will be present for local cursor activity.  
The first time you connect to the UltraView Remote 2 or switch CPU ports the cursors may be out of sync. Click on  
the Calibration tab on the toolbar  
and calibrate the Video + Mouse. After the calibration is complete, the mouse  
cursors  
will follow each other over the viewer window.  
Figure 17. VNC Viewer Toolbar  
Controls Tab  
When you click on the “Controls” tab, the below dropdown menu will display.  
65  
Single Mouse Mode  
This mode is for fast network connections where the cursor response is sufficient to provide instant visual feedback  
on the remote screen. When enabled, the cursor is ‘captured’ within the viewer window until you use the ‘escape’ hot  
keys. To escape from the single mouse mode, press F8 and then P. The single mouse mode does not require  
calibration and available only when using the VNC viewer.  
Resync Mouse  
This option has the same effect as the button on the menu bar and resynchronizes the local and remote mouse  
pointers.  
Refresh Screen  
This option refreshes the whole screen image to remove any artefacts from moved screen items. This is useful when  
using very low refresh rates on slow speed communication links.  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mouse Control  
This option displays a mouse control dialog box and is useful when the remote cursor is failing to respond correctly to  
your mouse movements, even after using the Re-sync and calibration mouse option.  
The mouse control dialog allows you to control the remote mouse cursor manually using a selection of buttons that  
you click with your local mouse. Additional options also allow you to restore the settings of a mouse that has failed to  
operate correctly.  
Keyboard Control  
This option displays a keyboard control dialog and is useful for sending keyboard combinations (to the host) that are  
needed regularly.  
When entering codes:  
+ means press down the key that follows  
– means release the key that follows  
+– means press down and release the key that follows  
* means wait 250ms (note: if a number immediately follows the asterisk, then the delay will equal the number, in  
milliseconds - *300 = 300 ms wait)  
It is automatically assumed that all keys specified will be released at the end, so there is no need to specify -Ctrl or -  
Alt if these keys are to be released together.  
See Appendix 7 for a list of key sequence codes that can be used.  
Examples:  
‘Ctrl + F12’ to invoke the KVM switch module’s OSD would be expressed as: +-Ctrl+-F12  
‘Ctrl + Esc’ to invoke the KVM switch module’s CPU port selection window would be expressed as: +-Ctrl+-Esc  
Video Settings  
This dialog provides access to all of the key video settings that determine image quality and link performance.  
Using automatic configurations  
Every setting can be individually subjected to an automatic configuration (click the appropriate ‘Auto’ button) and  
most can also be manually adjusted.  
Use the Calibrate All button to automatically determine the optimum settings for all items.  
Note: Before using the ‘Calibrate All’ option, if possible, remove on-screen display (OSD) elements generated  
by any connected KVM switches (such as a host name label or menu). These OSD elements use  
different video rates to those of the host system(s) and can affect the setting of the automatic threshold  
value. UltraView Remote-2 uses an improved calculation procedure to filter out the effect of these  
elements. However, best results are obtained when the screen contains only host system information.  
Note: To maximize performance, the threshold level is automatically increased by 50% when a slow link is  
detected.  
Note: If the UltraView Remote-2 is used with one or more KVM switches, the threshold needs to be higher  
than 32 due to the significant amounts of ‘noise’ that these switches introduce. The UltraView Remote-2  
configuration should detect such noise and adjust the threshold accordingly.  
Setting the Threshold manually  
Occasionally it can be useful to manually adjust the Threshold setting, in order to achieve a setting that best suits  
your particular requirements.  
1
2
Use the ‘Calibrate All’ function to ensure that all other settings are optimized.  
Click the Threshold left arrow button to decrement the setting by one and observe the ‘Display Activity’  
indicator.  
3
Repeat step 2 until the Display Activity indicator suddenly rises to a much higher level (i.e. 50%). This will  
mean that you have reached the noise boundary. At this point, increment the Threshold value by 2 or 3 points  
to achieve an optimum setting.  
Virtual Media  
The Remote Virtual Media feature is not implemented on this model  
Info  
When selected, this option displays an information dialog showing the current logged on users, the current host, its  
video mode and its mouse motion details.  
32  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Host Tab  
The “Host” tab on the toolbar allows you to easily switch to  
any CPU port on the unit or system. Each of the 128 Host  
locations can be set-up with the appropriate keyboard  
command to switch to that port. These keyboard  
commands are set-up from the “Configure, Host” tab. Using  
the Hosts tab method to switch between host computers  
assures that the screen calibration details for each host are  
reused. The alternative is to use KVM switch hotkey  
combinations (Ctrl + n enter) or the KVM switch on screen  
display (Ctrl + Esc). You must be logged on as  
administrator to configure the host parameters.  
To configure the Hosts feature, click on the “Configure” tab in the upper right corner of the viewer window. This will  
display the configuration options. Select “Host” from the option tabs and the Host configuration window will display  
as shown in Figure 18.  
1. Select (highlight) the Host slot to configure and the Host Configuration box will display.  
2. Enter the name for this position (Example: Computer 6). Enter the user names that will be given access to this  
host location. An * allows all users access or a list of users separated by commas (e.g. admin,nigel,andy,steve).  
3. Enter the Hotkey / KVM port keyboard command sequence to switch to the CPU port (+-ctrl+-6+enter) for  
locations 10 or greater like port 15, the command sequence would be +-ctrl+-1+-5+enter).  
When all needed host switching commands have been entered. Save the Host Configuration and also save the Host  
menu information. Once saved, you will return to the configuration menu. From the Configuration menu, return to  
the Host and click on the Hosts button on the viewer toolbar. The defined hosts will display in the dropdown menu.  
Click on any Host name and you will be immediately switched to that CPU port. The Host configuration feature can  
also be used to send any keyboard command sequence to the KVM switch module. It is recommended that only  
commands to switch to a CPU port are used. You can set-up a host location to display the KVM switch module’s  
OSD menu (+-Ctrl+-F12+Enter) but it is best to use the “Command, Keyboard” function for these types of commands.  
Figure 18. Host Configuration window  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using the VNC Viewer and not the Java applet, you can also directly access the KVM switch module using  
keyboard commands or the Hosts feature. Using the Java applet, each keyboard commands to instruct the KVM  
Switch module to exercise an option must be configured to either the “Command, Keyboard Control” tab or the Hosts  
tab.  
The easiest way to switch to a CPU port is invoke the Computer select window. To do this using the VNC viewer,  
press and release the Ctrl key, then within 2 seconds, press the Esc key. The computer select window will display  
listing all the computers connected to the UltraView Remote 2. This list will display the number of computers that  
was entered in the configure computer menu (See figure 13)  
Figure 19. Computer Select Window  
Using the up or down arrow keys, select the computer port to switch to and press enter. You will be immediately  
switched to that CPU port and the connected computer’s video will display. You will have complete control (if your  
security profile permits it) of that computer. All functions can be performed as if you were directly connected to that  
computer. Files can be opened, edited, and saved, and applications installed on that computer can be executed.  
34  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Keyboard Commands  
Keyboard commands can be used to further customize the KVM switch module. These commands can be invoked  
directly from a local or remote keyboard or from the “Command, Keyboard commands” tab on the VNC view toolbar.  
(To use the keyboard commands, you must be connected via the VNC viewer, not the java applet)  
The commands listed in the “Key sequence” column are direct keyboard commands, those in the “HotKey  
Command” column are the key sequence string to add the “Command, Keyboard Command” tab on the VNC  
viewer’s toolbar.  
Command  
OSD menu  
CPU select  
Key sequence  
<Ctrl> F12  
Description  
Displays on-screen menus  
List of CPUs to select  
HotKey Command  
+-ctrl+-f12  
<Ctrl> ESC  
+-ctrl+-esc  
Select  
computer  
<Ctrl> nnn where nnn  
= computer number  
Connects the KVM station to  
the selected computer.  
+-ctrl+-nnn  
Next computer  
<Ctrl> +  
<Ctrl> -  
Selects next sequential CPU +-ctrl+-+  
Previous  
computer  
Selects previous sequential  
+-ctrl+--  
CPU.  
Scan ON  
Scan OFF  
Display label  
Logoff  
<Ctrl> S  
<Ctrl> X  
<Ctrl> D  
<Ctlr> L  
Turns scan mode on  
Turns scan mode off  
Turns CPU label on/off  
+-ctrl+-s  
+-ctrl+-x  
+-ctrl+-d  
Disconnects from currently  
connected computer.  
+-ctrl+-l  
Set mode  
<Ctrl> Mnn <Enter>  
where nn = mode  
value from Table 5.  
Alternate way to configure  
keyboard and mouse.  
N/A  
Set resolution  
<Ctrl> Yn <Enter>  
where n = resolution  
value from Table 6  
Alternate way to set screen  
resolution when no video is  
present from a CPU..  
N/A  
N/A  
Screen saver  
time  
<Ctrl> Vnnn <Enter>  
where n = 0 –999 sec.  
Alternate way to set screen  
saver time.  
Null mouse  
command  
<Ctrl> N  
Used to re-sync a PS/2  
mouse.  
+-ctrl+-n  
+-ctrl+-o  
Reset mouse  
<Ctrl> O (alpha O)  
<Ctrl> R  
Resets computer’s mouse.  
Reset  
command  
Resets and enables mouse  
and keyboard on currently  
selected computer  
+-ctrl+-r  
Max computers <Ctrl> Pnnn  
Total ports used (all units)  
Number of expansion units.  
N/A  
N/A  
Units  
<Ctrl> Unn  
<Ctrl> Wnn  
Width  
Number of ports on  
expansion units.  
N/A  
Keep  
<Ctrl> K  
Saves to flash memory.  
+-Ctrl+-k  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trouble Shooting  
Troubleshooting  
Remote network users are unable to contact the unit  
Check that the correct address is being used by the remote users.  
Check the network settings. Check that the user’ network address has not been excluded in the IP access  
control section.  
If the UltraView Remote-2 is situated behind a firewall, check that the relevant ports are being allowed  
through the firewall and are being correctly routed.  
Check the front panel indicators, the LNK indicator should be on. If the network link is a 100Mbps connection,  
the 100 indicator should also be on.  
If connecting using the VNC Java applet, close the applet and connect using the VNC Viewer program. First  
time connections must connect using the VNC Viewer, not the Java applet.  
Remote IP address is locked out (Blacklisted)  
If the remote user logged on incorrectly five times using the VNC Viewer, try logging on using the Applet. If  
logging on using the Applet is successful, the IP address will be unlocked.  
If the remote user logged on incorrectly five times using the Applet, try logging on using the VNC Viewer. If  
logging on using the VNC Viewer is successful, the IP address will be unlocked.  
If both the VNC viewer and Applet login is denied access, remove power from the UltraView remote 2 for two  
to three seconds. This will reset the unit and unlock the IP address. If the UltraView Remote 2 unit is using  
DHCP, the previously assigned IP address may be changed to a different IP address when power is restored.  
Remote users will need to be informed of the new IP address. If you still have problems with a Blacklisted IP  
address, please contact Rose Electronics technical support.  
The remote cursor is not correctly responding to my mouse movements  
Recalibrate the mouse. When doing so, ensure that the host system does not have mouse cursor trails  
enabled and that the top left corner of the screen is clear of application windows.  
When logging on using VNC viewer, I cannot enter a username  
Either, the VNC viewer is an old version or only the admin user has been configured on the unit.  
When connecting to the UltraView Remote 2 unit, the video is out of sync.  
Make sure a computer is connected to CPU port #1 and operating. With no CPU on port #1, the viewer  
video may not sync properly  
Computer does not boot, keyboard or mouse error received.  
Cable is loose, reseat cable and on PC hit F1 to continue or reboot computer.  
Wrong cable or keyboard and mouse cables reversed.  
Cable is defective; try using cable from another computer.  
Port on the UltraView Pro is defective; try using another port on UltraView Pro. If the problem goes away port  
is defective.  
Port on computer is defective, try plugging in keyboard or mouse directly if problem remains computer port is  
defective. If power status LED not lit, fuse on motherboard may be blown.  
Computer keyboard and mouse not configured.  
Mouse driver does not load.  
If PS/2 type mouse, computer must be connected to UltraView Pro or mouse at boot-up time in order for  
mouse to be recognized by the computer. Reboot computer with UltraView Pro powered on and cable  
attached.  
If RS232 type mouse, make sure right COM port is being used and syntax of mouse driver is correct to  
search for the correct port.  
Computer keyboard and mouse not configured.  
36  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Can’t switch computers from keyboard  
Power to the UltraView Pro was removed for less than three seconds possibly causing keyboard to lock up.  
Disconnect and re-connect the keyboard.  
If PS/2 type keyboard and mouse cables may be reversed.  
Not using left control key. Using numeric keypad instead of keys on top row. Not releasing control key before  
typing in number. Waiting more than 2 seconds to enter computer number. Using caps lock or shift key.  
Wrong or missing characters from those typed  
For PCs, the mode of the keyboard does not match that of the computer. Issue the mode command, usually  
1 for IBM PS/2s, 3 for Unix computers, and 2 for all others. The default setting is mode 2. Sometimes an  
incorrect mode will confuse the computer or keyboard and require re-booting the computer or resetting the  
keyboard by unplugging and plugging it back in.  
Switch to Switch failure  
Verify the firmware in all like switches is the same revision.  
Mouse does not move  
Mouse not configured.  
UltraView Pro turned off after or not connected when computer  
booted or application using mouse run. Exit and re-enter application using mouse or issue reset command.  
PS/2 mouse was not connected when UltraView Pro powered up or disconnected and reconnected. Issue  
the reset command or reconfigure the mouse.  
PS/2 mouse gets out of sync  
Cabling was disturbed during mouse movement. Issue the null command once or twice to re-sync the mouse.  
Update mouse driver. Try using ctrl O command to recover if O/S is NT.  
Sun keyboard needs to be reset, with unit power on, disconnect and re-connect the sun keyboard.  
Video fuzzy  
Cable too long or wrong type. Verify that resolution and distance match. See Appendix G. Upgrade cable if  
necessary.  
Video not synchronized or wrong color  
Cable is loose, reseat cable.  
Monitor not capable of syncing to video selected, upgrade monitor.  
Cable is defective; try using cable from another computer if problem goes away cable is defective.  
Port on UltraView Pro is defective; try using another port on UltraView Pro. If problem goes away port is  
defective.  
Lower resolution OK, but can’t enter high resolution mode  
Video driver has not been setup for this resolution. Configure the driver.  
Slave unit does not switch  
Maximum ports command not issued.  
Width or units command not configured properly. Reconfigure them to match number of computers and how  
they are connected.  
On-screen display not synchronized  
No video from computer or resolution setting not configured correctly.  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Service and Support  
Maintenance and Repair  
This Unit does not contain any internal user-serviceable parts. In the event a Unit needs repair or maintenance, you  
must first obtain a Return Authorization (RA) number from Rose Electronics or an authorized repair center. This  
Return Authorization number must appear on the outside of the shipping container. See Limited Warranty for more  
information.  
When returning a Unit, it should be double-packed in the original container or equivalent, insured and shipped to:  
Rose Electronics  
Attn: RA__________  
10707 Stancliff Road  
Houston, Texas 77099 USA  
Technical Support  
If you are experiencing problems, or need assistance in setting up, configuring or operating your switch, consult the  
appropriate sections of this manual. If, however, you require additional information or assistance, please contact the  
Rose Electronics Technical Support Department at:  
Phone: (281) 933-7673  
E-Mail: TechSupport@rose.com  
Technical Support hours are from: 8:00 am to 6:00 pm CST (USA), Monday through Friday.  
Please report any malfunctions in the operation of this Unit or any discrepancies in this manual to the Rose  
Electronics Technical Support Department.  
38  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY  
Safety  
This Unit has been tested for conformance to safety regulations and requirements, and has been certified for  
international use. Like all electronic equipment, the Unit should be used with care. To protect yourself from possible  
injury and to minimize the risk of damage to this Unit, read and follow these safety instructions.  
Caution!  
Risk of explosion can occur if the battery is replaced with an incorrect type.  
Dispose of used batteries according to the manufacturer’s instructions.  
Follow all instructions and warnings marked on this Unit.  
Except where explained in this manual, do not attempt to service this Unit yourself.  
Do not use this Unit near water.  
Assure that the placement of this Unit is on a stable surface or rack mounted.  
Provide proper ventilation and air circulation.  
Keep power cord and connection cables clear of obstructions that might cause damage to them.  
Use only power cords, power transformer and connection cables designed for this Unit.  
Use only a grounded (three-wire) electrical outlet.  
Keep objects that might damage this Unit and liquids that may spill, clear from this Unit. Liquids and foreign  
objects might come in contact with voltage points that could create a risk of fire or electrical shock.  
Operate this Unit only when the cover is in place.  
Do not use liquid or aerosol cleaners to clean this Unit. Always unplug this Unit from its electrical outlet before  
cleaning.  
Unplug this Unit from the electrical outlet and refer servicing to a qualified service center if any of the following  
conditions occur:  
.
.
.
.
.
The power cord or connection cables is damaged or frayed.  
The Unit has been exposed to any liquids.  
The Unit does not operate normally when all operating instructions have been followed.  
The Unit has been dropped or the case has been damaged.  
The Unit exhibits a distinct change in performance, indicating a need for service.  
Safety and EMC Regulatory Statements  
Safety Information  
Documentation reference symbol. If the product is marked with this symbol, refer to the product  
documentation to get more information about the product.  
WARNING  
CAUTION  
A WARNING in the manual denotes a hazard that can cause injury or death.  
A CAUTION in the manual denotes a hazard that can damage equipment.  
Do not proceed beyond a WARNING or CAUTION notice until you have understood the hazardous conditions and  
have taken appropriate steps.  
Grounding  
These are Safety Class I products and have protective earthing terminals. There must be an un-interruptible safety  
earth ground from the main power source to the product’s input wiring terminals, power cord, or supplied power cord  
set. Whenever it is likely that the protection has been impaired, disconnect the power cord until the ground has been  
restored.  
Servicing  
There are no user-serviceable parts inside these products. Only service-trained personnel must perform any  
servicing, maintenance, or repair.  
The user may adjust only items mentioned in this manual.  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPENDICES  
Appendix A – Specifications  
Dimensions  
4 / 8 port  
16 port  
Width  
Depth  
Height  
16.7” / 42.4cm  
16.7” / 42.4cm  
15.2” / 38.6cm  
15.2” / 38.6cm  
1.75” / 4.5cm  
3.50” / 9.0 cm  
Weight  
4-port units  
8-port units  
16-port units  
6.9 lbs / 3.1 kg  
9.3 lbs / 4.2 kg  
14.0 lbs / 6.4 kg  
Connectors  
Power  
IEC320  
CPU ports  
KVM port  
RS232  
DB25F  
DB25F  
RJ45F  
RJ11F  
Network  
Video Bandwidth  
Controls  
150 MHz  
All controls are performed using an on-screen menu system  
LED’s: Power,  
Indicators  
Chassis  
Electro-galvanized steel, black powder coated  
0° - 45° C, 32° - 113° F  
Environmental  
Humidity  
5% - 80% non-condensing  
Approvals  
FCC, CE  
Appendix B – Parts and cables  
Part Number  
UPR-1R04UB/2  
UPR-1R08UB/2  
UPR-1R16UB/2  
UER-1R04UB/2  
UER-1R08UB/2  
UER-1R16UB/2  
CAB-CX0606Cnnn  
CAB-ZX0606Mnnn  
RM-UBnn  
Description  
PC platform – 4 port / local-remote access  
PC platform – 8-port / local-remote access  
PC platform – 16-port / local-remote access  
Multiplatform – 4-port / local-remote access  
Multiplatform – 8-port / local-remote access  
Multiplatform – 16-port / local-remote access  
DB25 to HD15/PS2/PS2 (Unit to Computers)  
DB25 to HD15/PS2/PS2 (Unit to KVM Station)  
Rack mount kit for 4 / 8 port units  
RM-UCnn  
Rack mount kit for 16 port unit  
(nnn = length in feet)  
(1U chassis) nn= 19”, 23”, or 24”  
(2U chassis) nn= 19”, 23”, or 24”  
40  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix C - RackMount  
The rack mount kit includes the following items:  
Two black anodized mounting brackets  
Four 6 - 32 x 3/8” flat head mounting screws  
To rack mount your UltraView Remote 2 unit, attach the two rack mounting brackets to your Unit with the short flange  
against the Unit using the four screws provided. Secure the mounting brackets to the rack using the appropriate size  
bolts, nuts and lock washers. Using hardware other than that provided could cause damage to the electronics and/or  
result in loss of mounting integrity. Do not over tighten the screws used to mount the Unit to the mounting brackets.  
The following general guidelines should be observed when installing your Unit into a rack.  
a). The UltraView Remote 2 is designed to work in an ambient temperature of 0ο C to 45ο C (32ο F – 113ο F).  
b). Do not block power supply vents or otherwise restrict airflow when rack-mounting this Unit.  
c). Mechanical loading of the rack should be considered to prevent instability and possible tipping over.  
d). Tighten all connectors securely and provide adequate strain relief for all cables.  
e). Provide a grounded power source to all Units. Pay special attention to overall branch circuit load ratings before  
connecting equipment to this source. Overloaded circuits are potential fire hazards and can cause equipment  
failures or poor performance.  
Rack mount illustration  
Appendix D – Firmware upgrade  
When updates and enhancements are made to the UltraView Remote 2 features, new firmware updates are made  
To check the firmware revision of the UltraView Remote 2 that you are connected to, click on Commend, then Info.  
This screen will show the version of the unit’s firmware Check this version against the latest version on our web site.  
If your Unit needs updating, download the need update file from our web site and save it on the workstation.  
To update the UltraView Remote 2 Unit:  
(Note: Administration login is required to update the UltraView Remote 2 firmware)  
Connect and log into the UltraView Remote 2 from a network workstation with admin privileges.  
The firmware upgrade file must be saved on this network workstation.  
Click on the Configure tab in the upper right corner of the Viewer window.  
When the Configure menu displays, click on the Unit Configuration tab.  
When the Unit configuration menu displays, click on the Advanced Unit Configuration tab  
The Advanced Unit Configuration window is where the firmware upgrade feature is offered. Click on the  
Firmware Upgrade tab and follow the on-screen instructions to update the firmware.  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix E – IP Access Control  
Setting IP access control  
The golden rule with this feature is ‘Include before you exclude’ or to put it another way ‘Arrange allowed addresses  
in the list before the denied addresses’.  
This is because the positions of entries in the list are vitally important. Once a range of addresses is denied access, it  
is not possible to make exceptions for particular addresses within that range. For instance, if the range of addresses  
from A to F are denied access first, then the address C could not be granted access lower down the list. Address C  
needs to be placed in the list before the denied range.  
IMPORTANT: This feature should be configured with extreme caution as it is possible to deny access to everyone. If  
such an error occurs, see Clear IP access control for details about how to regain access.  
In the list, access control addresses prefixed by ‘+’ are allow entries while those prefixed  
by ‘– ‘ are deny entries.  
To define a new IP access control entry, click the Add button to display a popup dialog:  
Network/Address  
Enter the network address that is allowed or denied access. If a range of  
addresses is being specified then specify any one of the addresses within  
the range and use the Mask entry to indicate the size of the range. (See  
address range and mask sections)  
The IP access control function uses a standard IP address and a net mask notation to specify both single locations  
and ranges of addresses. In order to use this function correctly, you need to calculate the mask so that it accurately  
encompasses the required addresses.  
Single locations  
Some of the simplest addresses to allow or deny are single locations. In this case you enter the required IP address  
into the ‘Network/Address’ field and simply enter the ‘Mask’ as 255.255.255.255 (255 used throughout the mask  
means that every bit of the address will be compared and so there can only be one unique address to match the one  
stated in the ‘Network/Address’ field).  
All locations  
The other easy setting to make is ALL addresses are allowed or denied. Using the mask 0.0.0.0 as standard, the IP  
access control section includes the entry: +0.0.0.0/0.0.0.0.The purpose of this entry is to include all IP addresses. It  
is possible to similarly exclude all addresses, however, take great care not to do this as you instantly render all  
network access void. There is a recovery procedure should this occur.  
Address ranges  
Although you can define ranges of addresses, due to the way the mask operates, there are certain restrictions on the  
particular ranges that can be set. For any given address you can encompass neighboring addresses in blocks of  
either 2, 4, 8, 16, 32, 64, 128, etc. and these must fall on particular boundaries. For instance, if you wanted to define  
the local address range:  
192.168.142.67 to 192.168.142.93  
The closest single block to cover the range would be the 32 addresses from:  
192.168.142.64 to 192.168.142.95.  
The mask needed to accomplish this would be: 255.255.255.224  
When you look at the mask in binary, the picture becomes a little clearer. The above mask has the form:  
11111111.11111111.11111111.11100000  
42  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ignoring the initial three octets, the final six zeroes of the mask would ensure that the 32 addresses from .64  
(01000000) to .95 (01011111) would all be treated in the same manner. See Net masks - the binary explanation for  
details.  
When defining a mask, the important rule to remember is:  
There must be no ‘ones’ to the right of a ‘zero’.  
For instance, (ignoring the first three octets) you could not use a mask that had 11100110 because this would affect  
intermittent addresses within a range in an impractical manner. The same rule applies across the octets. For  
example, if you have zeroes in the third octet, then all of the fourth octet must be zeroes.  
The permissible mask values (for all octets) are as follows:  
Mask octet  
Binary Number of addresses encompassed  
255  
254  
252  
248  
240  
224  
192  
128  
0
11111111  
11111110  
1 address  
2 addresses  
4 addresses  
8 addresses  
16 addresses  
32 addresses  
64 addresses  
128 addresses  
256 addresses  
11111100  
11111000  
11110000  
11100000  
11000000  
10000000  
00000000  
If the access control range that you need to define is not possible using one address and one mask, then you could  
break it down into two or more entries. Each of these entries could then use smaller ranges (of differing sizes) that,  
when combined with the other entries, cover the range that you require.  
For instance, to accurately encompass the range in the earlier example:  
192.168.142.67 to 192.168.142.93  
You would need to define the following six address / mask combinations in the IP access control section:  
Network/address entry Mask entry  
192.168.142.67 255.255.255.255  
192.168.142.68 255.255.255.252  
192.168.142.72 255.255.255.248  
192.168.142.80 255.255.255.248  
192.168.142.88 255.255.255.252  
192.168.142.93 255.255.255.255  
defines 1 address (.67)  
defines 4 addresses (.68 to .71)  
defines 8 addresses (.72 to .79)  
defines 8 addresses (.80 to .87)  
defines 4 addresses (.88 to .92)  
defines 1 address (.93)  
Mask  
Enter an IP network mask that indicates the range of addresses that will be allowed or denied access. For instance, if  
only a single specified IP address were required, the mask entry would be 255.255.255.255 in order to specify a  
single location.  
Access  
Use the arrow buttons to select either ‘Allow’ or ‘Deny’ as appropriate.  
1
2
Enter the base network address, the mask and select the appropriate access setting.  
Click the OK button.  
To reorder access control entries  
IMPORTANT: When reordering, ensure that any specific allowed addresses are listed higher in the list than any  
denied addresses. Take care not to invoke any deny access settings that would exclude valid users.  
1
2
In the access control list, click on the entry to be moved.  
Click the Up or Down buttons as appropriate.  
To edit/remove access control entries  
1
2
In the access control list, click on the appropriate entry.  
Click either the Edit or Remove button as appropriate.  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix F – VNC Viewer connection options  
When you are connecting to the UltraView Remote 2 unit using the VNC viewer, a number of options are  
available.  
Click the Options… button  
There are six tabbed pages of options:  
Color/Encoding  
Auto select  
When ticked, this option will examine the speed of your connection to the  
UltraView Remote 2 unit and apply the most suitable encoding method. This  
option is suggested for the majority of installations.  
Preferred encoding  
There are three manually selectable encoding methods which are accessible  
when the Auto select option is un-ticked.  
ZRLE – This is a highly compressed method that is best suited to slow modem  
connections.  
Hextile – This method offers better performance than the ZRLE when used  
over a high speed network because there is no need for the UltraView  
Remote 2 to spend time highly compressing the data.  
Raw – This is a primitive, uncompressed method that is mainly used for  
technical support issues. You are recommended not to use this method.  
Color level  
This section allows you to select the most appropriate color level for the speed of  
the connection to the UltraView Remote 2 unit. Where the connection speed is  
slow or inconsistent there will be a necessary compromise between screen  
response and color depth.  
Full – This mode is suitable only for fast network connections and will pass on  
the maximum color depth being used by the host system.  
Medium (256 colors) – This mode reduces the host system output to a 256  
color mode and is more suitable for ISDN and fast modem connections.  
Low (64 colors) – This mode is suitable for slower modem connections and  
reduces the host system output to 64 colors.  
Very low (8 colors) – This mode provides very rudimentary picture quality and  
hardly any speed advantage over the 64 color setting. You are recommended  
not to use this mode.  
44  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Scaling  
No Scaling  
No attempt is made to make the screen image fit the viewer window. You may  
need to scroll horizontally and/or vertically to view all parts of the screen image.  
Scale to Window Size  
Adjusts the server screen image to suit the size of the viewer window.  
Custom Size  
Adjusts the server screen image according to the Width and Height settings in  
the adjacent fields. A drop box to the right of the fields allows you to define the  
image size by percentage or by pixels, as required.  
Preserve Aspect Ratio  
When ticked, maintains a consistent ratio between the horizontal and vertical  
dimensions of the screen image.  
Inputs  
These feature do not apply to the UltraView Remote 2 unit installations.  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Misc  
Shared connection (do not disconnect other viewers)  
This option does not apply to UltraView Remote 2 unit.  
Full screen mode  
When ticked, the VNC viewer will launch in full screen mode. Use the menu key  
(usually F8) to exit from full screen mode.  
Full-screen mode matches server resolution  
This option does not apply to UltraView Remote 2 unit.  
Full-screen mode uses all monitors  
This option does not apply to UltraView Remote 2 unit  
Render cursor locally  
This option does not currently apply to UltraView Remote 2 unit.  
Allow dynamic desktop resizing  
When ticked, the viewer window will be automatically resized whenever the host  
system’s screen resolution is altered.  
Only use protocol version 3.3  
This option does not apply to UltraView Remote 2 unit.  
Beep when requested to by the server  
When ticked, your local system will beep in response to any error beeps emitted  
by the UltraView Remote 2.  
Offer to automatically reconnect  
When ticked, the viewer will offer to restore a lost connection with the server.  
Try Single Sign-On if server allows it  
This option does not apply to UltraView Remote 2 unit.  
Enable file transfer  
This feature does not apply to the UltraView Remote 2 unit installations.  
Identities  
This feature helps your VNC viewer to confirm that a revisited UltraView Remote  
2 unit is genuine and not another device masquerading as an UltraView Remote  
2. The list given will retain the identities of all visited units (that have full security  
enabled).  
When you first make a secure connection to the UltraView Remote 2, the  
security information for that UltraView Remote unit is cached within this Identities  
tab (i.e. the “identity” is known). The next time that you connect to the UltraView  
Remote 2 unit, its identity is checked against the stored version. If a mismatch is  
found between the current and the stored identities then a warning will be issued  
to you.  
If an existing UltraView Remote 2 unit is fully reconfigured then it will need to be  
issued with a new identity. In this case the previous identity, listed in this tab,  
should be removed so that a new identity can be created on the next connection.  
46  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Load / Save  
Configuration File - Reload  
Allows you to load a configuration file saved from this, or another viewer.  
Configuration File - Save  
Allows you to save the current settings so that they can be copied from one  
viewer to another.  
Configuration File - Save As...  
Allows you to save the current settings under a new name so that they can be  
copied from one viewer to another.  
Defaults - Reload  
When clicked, all connection options are returned to the default settings that are  
currently saved.  
Defaults - Save  
When clicked, saves the current connection options as the default set that will be  
used in all subsequent VNC connections.  
Appendix G – VNC viewer window options  
Click the VNC icon in the top left corner of the viewer window (or press F8) to display the window options:  
Standard window control items  
Restore, Move, Size, Minimize, Maximize, and Close control the VNC window as per any other  
application.  
Full screen  
Expands the VNC viewer window to fill the whole screen with no visible window edges or toolbar.  
Press F8 to redisplay this menu.  
Single mouse mode (P)  
Used for fast network connections where a second, “predictor” cursor is not required.  
Ctrl, Alt, Send F8, Send Ctrl-Alt-Del  
Sends the selected key press(es) to the UltraView Remote 2 and the host system. This is  
necessary because certain keys and key combinations are trapped by the VNC viewer.  
Refresh Screen  
Requests data from the server for a complete redraw of the screen image, not just the items that  
change.  
Virtual Media...  
This feature is not available for the UltraView Remote 2 unit  
New Connection...  
Displays the connection dialog so that you can log on to a different UltraView Remote 2 unit or  
VNC server location.  
Options...  
Displays the full range of connection option  
Connection Info...  
Displays various connection and display details.  
About...  
Displays information about your VNC viewer.  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix H – Browser viewer options  
When you are connecting to the UltraView Remote 2 unit using a Web browser and the VNC applet, a number of  
options are available.  
Click the Options… button  
There are four options pages:  
Encoding and color level  
Auto select  
When ticked, this option will examine the speed of your connection to the UltraView Remote 2  
and apply the most suitable encoding method. This option is suggested for the majority of  
installations.  
Preferred encoding  
There are three manually selectable encoding methods which are accessible when the Auto  
select option is un-ticked.  
ZRLE – This is a highly compressed method that is best suited to slow modem connections.  
Hextile – This method offers better performance than the ZRLE when used over a high speed  
network because there is no need for the UltraView Remote 2 unit to spend time highly  
compressing the data.  
Raw – This is a primitive, uncompressed method that is mainly used for technical support  
issues. You are recommended not to use this method.  
Color level  
The color level is fixed at Medium (256 colors) for almost all browsers.  
Inputs  
View only (ignore mouse & keyboard)  
When ticked, the viewer will not send keyboard or mouse information to the UltraView Remote 2  
unit or host system.  
Accept clipboard from server  
This feature is restricted to software server versions of VNC and has no effect on UltraView  
Remote 2 unit installations.  
Send clipboard to server  
This feature is restricted to software server versions of VNC and has no effect on UltraView  
Remote 2 unit installations.  
Security  
512 bits (low security)  
Selects the lowest level of encoding for communications between the browser and the UltraView  
Remote 2 unit.  
1024 bits (medium security)  
Selects the middle level of encoding for communications between the browser and the  
UltraView Remote 2 unit.  
2048 bits (high security)  
Selects the highest level of encoding for communications between the browser and the  
UltraView Remote 2 unit.  
48  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Misc  
Shared (don’t disconnect other viewers)  
This feature is restricted to software server versions of VNC and has no effect on UltraView  
Remote 2 unit installations.  
Render cursor locally  
This feature is restricted to software server versions of VNC and has no effect on UltraView  
Remote 2 unit installations.  
Fast CopyRect  
This feature is restricted to software server versions of VNC and has no effect on UltraView  
Remote 2 unit installations.  
Appendix I – Supported video modes  
The following video modes are supported and can be automatically configured by the UltraView Remote 2. If a  
recognised video mode cannot be found, the UltraView Remote 2 will gradually change some of the key parameters  
to discover whether a video lock can be achieved. Support for VESA GTF (Generalized Timing Formula) is available  
and can be enabled via the Advanced Unit Configuration screen.  
The half width video modes capture every other pixel. These are not generally recommended for normal use but may  
be used for emergency access to high resolution, high frequency system screens. Half width screens can be  
expanded to normal width using the scaling features of the viewer.  
vesa 720 x 400 @ 85Hz  
vesa 640 x 480 @ 60Hz  
vesa 1152 x 864 @ 75Hz  
vesa 1280 x 960 @ 60Hz  
vesa 1280 x 1024 @ 60Hz  
vesa 1280 x 1024 @ 75Hz  
vesa 1600 x 1200 @ 60Hz  
vesa 720 x 400 @ 70Hz*  
vesa 640 x 480 @ 72Hz  
vesa 640 x 480 @ 75Hz  
vesa 640 x 480 @ 85Hz  
vesa 800 x 600 @ 56Hz  
vesa 800 x 600 @ 60Hz  
sun 1152 x 900 @ 66Hz  
sun 1152 x 900 @ 76Hz  
sun 1280 x 1024 @ 67Hz  
apple 640 x 480 @ 67Hz  
apple 832 x 624 @ 75Hz  
apple 1152 x 870 @ 75Hz  
vesa 800 x 600 @ 72Hz  
vesa 800 x 600 @ 75Hz  
vesa 800 x 600 @ 85Hz  
vesa 1024 x 768 @ 60Hz  
vesa 1024 x 768 @ 70Hz  
vesa 1024 x 768 @ 75Hz  
vesa 1024 x 768 @ 85Hz  
* Not actually a VESA mode but a common DOS/BIOS mode  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix J – Hotkey sequence codes  
These codes are used when defining hotkey switching sequences (macros) for host computers and allow you to  
include almost any of the special keys on the keyboard.  
Permissible key presses  
Main control keys (see ‘Using abbreviations’  
Backspace | Tab | Return | Enter | Ctrl | Alt | Win | Shift | LShift | RShift  
LCtrl | RCtrl | LAlt | AltGr | RAlt | LWin | RWin | Menu | Escape | Space  
CapsLock | NumLock | PrintScreen | Scrolllock  
Math operand keys (see ‘Using abbreviations’)  
Add (Plus) | Subtract (Minus) | Multiply  
Central control keys (see ‘Using abbreviations’)  
Insert | Delete | Home | End | PageUp | PageDown  
Up | Down | Left | Right | Print | Pause  
Keypad keys (see ‘Using abbreviations’)  
KP_Insert | KP_Delete | KP_Home | KP_End | KP_PageUp  
KP_PageDown | KP_Up | KP_Down | KP_Left | KP_Right | KP_Enter  
KP_Add | KP_Subtract | KP_Divide | KP_Multiply  
KP_0 to KP_9  
Function keys  
F1 | F2 | F3 | F4 | F5 | F6 | F7 | F8 | F9 | F10 | F11 | F12  
ASCII characters  
All characters can be entered using their ASCII codes, from 32 to 126 (i.e. A,B,C, … 1,2,3 etc.) with the exception  
of the special characters ‘+’, ‘-’, ‘+–’ and ‘*’ which have special meanings, as explained below.  
Codes with special meanings  
+
means press down the key that follows  
means release the key that follows  
+– means press down and release the key that follows  
*
means wait 250ms (note: if a number immediately follows the asterisk, then the delay will equal the number,  
in milliseconds)  
Note: Hotkey sequences are not case sensitive.  
Creating macro sequences  
Hot key macro sequences can be up to 256 characters long. All keys are assumed to be released at the end of a  
line, however, you can also determine that a key is pressed and released within a sequence. Any of the following  
three examples will send a command that emulates a press and release of the Scroll Lock key:  
+SCROLL-SCROLL  
+-SCROLL  
+SCROLL-  
Example:  
+-SCROLL+-SCROLL+1+ENTER  
Press and release scroll twice, press 1 then enter then release all keys (equivalent definition is +SCROLL-  
SCROLL+SCROLL-SCROLL+1+ENTER-1-ENTER)  
Using abbreviations  
To reduce the length of the key definitions, any unique abbreviation for a key can be used. For example: “scroll”,  
“scr” and even “sc” all provide an identifiable match for “ScrollLock” whereas “en” could not be used because it  
might mean “Enter” or “End” (“ent” would be suitable for “Enter”).  
Note: Hotkey sequences and abbreviations are not case sensitive.  
50  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix K – Video distance capability  
The table below shows the distances, resolution, and quality of video that can be expected with normal or coax  
cabling. This table applies to the MASTER unit only. There will be some degradation when units are chained  
together.  
Resolution  
5’  
10’  
20’  
30’  
50’  
C4  
C4  
C4  
C4  
C4  
C3  
75’  
C4  
C4  
C4  
C4  
C3  
C3  
100’ 125’ 150’ 200’  
640x480  
60Hz refresh  
N4  
C4  
N4  
C4  
N4  
C4  
N4  
C4  
C4  
C4  
C4  
C3  
C3  
C4  
C3  
C3  
C3  
C3  
C3  
C3  
C3  
C3  
C3  
C3  
C3  
C3  
C3  
640x480  
72-75Hz refresh  
N4  
C4  
N4  
C4  
N4  
C4  
N3  
C4  
800x600  
non-interlaced  
N4  
C4  
N4  
C4  
N3  
C4  
N3  
C4  
1024x768  
interlaced  
N4  
C4  
N3  
C4  
N3  
C4  
N3  
C4  
1024x768  
non-interlaced  
N4  
C4  
N3  
C4  
N3  
C4  
N3  
C4  
1280x1024  
interlaced  
N3  
C4  
C4  
C4  
C3  
C3  
C3  
C3  
1280x1024  
non-interlaced  
N3  
C4  
Legend  
4- Perfect or near-perfect video; Unable to  
easily detect defects.  
3- Very acceptable; Images clear, small  
reflections around colored letters  
2- Acceptable: Slightly fuzzy images,  
N – Normal cabling  
C – Coax cabling  
readable text, acceptable usage for short  
periods of time, can cause eye fatigue.  
1- Unusable; images smeared, text not easily  
readable.  
ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES:  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10707 Stancliff Road  
Houston, Texas 77099  
Phone: (281) 933-7673  
WWW.ROSE.COM  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Quantum Instruments Cassette Player DLT 7000 User Guide
Radio Shack Network Router 25 3187 User Guide
Radio Shack Two Way Radio 21 1904 User Guide
Remington Trimmer MPT 2000 User Guide
Ricoh Camcorder RICOH WG 5 User Guide
Roberts Radio Radio RDK 2 User Guide
Rockford Fosgate Portable Speaker P152S User Guide
Rover Lawn Mower 7091 User Guide
Samsung Home Security System P4042 User Guide
SEH Computertechnik Printer PS1109 User Guide