FOR YOUR SAFETY
If you smell gas:
1. Open windows.
2. DO NOT try to light any
appliance.
3. DO NOT use electrical
switches.
4. DO NOT use any telephone
in your building.
5. Leave the building.
6. Immediately call your local
gas supplier after leaving
the building. Follow the gas
suppliers instructions.
7. If you cannot reach your gas
supplier, call the Fire
Department.
Blackheat®
Vacuum Assisted
Linear & U-Tube
Gas Fired Radiant
Heating
DO NOT store or use petrol or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
Systems
Installation, Operation &
Service Manual
BH15
BH20
BH25
BH30
BH35
BH40
BH45
BH50
WARNING
Installer
Improper installation, adjustment, alteration, service
or maintenance can result in death, injury or property
damage. Read the installation, operation and service
manual thoroughly before installing or servicing
this equipment.
Please take the time to read and understand
these instructions prior to any installation.
Installer must give a copy of this manual to the owner.
Owner
Installation must be done by a contractor qualified
in the installation and service of gas-fired heating
equipment.
Keep this manual in a safe place to provide your
serviceman with information should it become
necessary.
Hurll Nu-Way Pty Ltd
14 Aristoc Road
GLEN WAVERLEYVIC3150
Telephone: +61 3 9561 2100
Fax: +61 3 9560 8992
www.rg-inc.com
170101AUNZ
Rev. 2
4/03
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF FIGURES
Figure 1: Deleted
Figure 2: Linear Horizontal Mounts ...............4
Figure 3: Linear, One Side Reflector..............4
Figure 4: Linear, Two Side Reflectors ............4
Figure 5: Linear, 45° Mount............................4
Figure 6: Linear, 1 Foot and 2 Foot Deco
Grille ..........................................................................5
Figure 7: Linear, Protective Grille...................5
Figure 8: Linear, Venting ................................5
Figure 9: U-Tube, Horizontal Mount..........................................6
Figure 10: U-Tube, One Side Reflector.....................................6
Figure 11: U-Tube, Two Side Reflectors ...................................6
Figure 12: U-Tube, Full 45° Mount............................................6
Figure 13: U-Tube, Opposite 45° Tilt.........................................7
Figure 14: U-Tube, Protective Grille..........................................7
Figure 15: U-Tube, Venting .......................................................7
Figure 16: BLACKHEAT® Linear and U-Tube ........................10
Figure 17: BLACKHEAT® Linear General Assembly
Overview................................................................14
Figure 18: BLACKHEAT® Linear Layout Overviews ..............15
Figure 19: Deleted
Figure 20: Deleted
Figure 21: Reflector Overlap Detail.........................................22
Figure 22: BLACKHEAT® BH15UT Assembly Overview .......25
Figure 23: BLACKHEAT® U-Tube Layout Overviews.............26
Figure 24: Deleted
Figure 25: Typical Manifold Layout (Linear and U-Tube
Configuration) ........................................................32
Figure 26: Individual Flue Connection Detail ..........................42
Figure 27: Fresh Air Intake Spigot ..........................................43
Figure 28: Air Supply with Flue Configurations.......................43
Figure 29: Gas Connection with Stainless Steel Flex
Connector ..............................................................44
Figure 30: Sequence of Operation Chart................................48
Figure 31: Burner Cup Position...............................................50
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 1: HEATER SAFETY
SECTION 1: HEATER SAFETY
Your Safety is Important to Us!
A wall tag is supplied with the BLACKHEAT® heater as a
This symbol is used throughout the manual
permanent reminder of the safety instructions and the
to notify you of possible fire, electrical or burn importance of the minimum required clearances to
hazards. Please pay special attention when
reading and following the warnings in these
sections.
combustibles. A copy of the wall tag is illustrated on Page
2, Figure 1. Peel off the backing of the adhesive strips on
the rear surface of the tag and position the tag on a wall
near the BLACKHEAT® heater (e.g. thermostat or
ROBERTS GORDON® BZC Microprocessor Controller).
WARNING
2.2 Halogenated Hydrocarbons
Installation, Service and Annual Inspection of heater
must be done by a contractor qualified in the
CAUTION
installation and service of gas-fired heating equipment.
Do not use heater in an area containing corrosive
chemicals.
Read this manual carefully before installation,
operation, or service of this equipment.
Avoid the use of corrosive chemicals to ensure a
longer life of the burner, tubing and other parts.
Failure to follow these instructions can result in death,
injury or property damage.
Failure to follow these instructions can result in
property damage.
This heater is designed for heating non-residential indoor Roberts-Gordon cannot be responsible for ensuring that
all appropriate safety measures are undertaken prior to
installation; this is entirely the responsibility of the
installer. It is essential that the contractor, the sub-
contractor, or the owner identifies the presence of
combustible materials or halogenated hydrocarbons*
anywhere in the premises.
spaces. Do not install in residential spaces. These
instructions,layouts,AS5601/AG 601,local codes and
ordinances, and applicable standards that apply to gas
piping, electrical wiring, venting, etc., must be thoroughly
understood before proceeding with the installation.
SECTION 2: INSTALLER RESPONSIBILITY
• To install the heater, as well as the gas and electrical
supplies, in accordance with applicable specifications
and codes. Roberts-Gordon recommends the
installer contact a local building inspector or Fire
Marshal for guidance.
* Halogenated Hydrocarbons are a family of chemical com-
pounds characterized by the presence of halogen elements
(flourine, chlorine, bromine, etc.). These compounds are
frequently used in refrigerants, cleaning agents, solvents, etc. If
these compounds enter the air supply of the burner, the lifespan
of the heater components will be greatly reduced. An outside air
supply must be provided to the burners whenever the presence
of these compounds is suspected. Warranty will be invalid if the
heater is exposed to halogenated hydrocarbons.
• To use the information given in a layout drawing and
in the manual together with the cited codes and
regulations to perform the installation.
2.3 National Standards and Applicable Codes
All Appliances must be installed in accordance with the
latest revision of AS5601/AG601 and other relevant
codes. This refers also to the electric, gas and venting
installation. Note: Additional standards for installations in
Public Garages, Aircraft Hangars, etc. may be applicable.
• To install the heater in accordance with the Clear-
ances to Combustibles.
• To furnish all needed materials not furnished as
standard equipment.
• To plan location of supports.
• To provide access to burners for servicing on all
sides, for burner removal.
• To provide the owner with a copy of this installation,
operation and service manual.
• To never use heater as support for ladder or other
access equipment and never hang or suspend any-
thing from heater.
2.1 Low Level User Instructions
In all situations, clearances to combustibles must be
maintained. Failure to observe clearances to
combustibles can result in death, severe injury or
property damage. Signs should be posted in storage
areas to specify the maximum stacking height of items
placed below heater to maintain required clearances to
combustibles. Minimum clearances must be maintained
from vehicles parked below the heater. Caution should be
used when running the system near combustible
materials such as wood, paper, rubber, etc.
Consideration should be given to partitions, storage
racks, hoists, building construction,etc.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 3: CRITICAL CONSIDERATIONS
SECTION 3: CRITICAL CONSIDERATIONS
WARNING
Fire Hazard
Burn Hazard
Some objects will catch fire Keep all persons,
or explode when placed
close to heater.
especially children, away
from heater.
Keep all flammable objects, Do not touch any part of
liquids and vapors the
minimum required
the heater.
Heater is very hot.
clearances to combustibles
away from heater.
Failure to follow these
instructions can result in
severe injury.
Failure to follow these
instructions can result in
death or injury.
3.1 Minimum Required Clearances to Combustibles
Clearances are the required distances that combustible
objects must be kept away from the heater to prevent
serious fire hazards. Combustibles are materials, which
may catch on fire and include common items such as
wood, paper, rubber, fabric, etc. Maintain clearances to
combustibles at all times for your safety.
Clearances for all heater models are located on Page 4,
Figure 2 through Page 7, Figure 15 in this manual. Check
the clearances on each burner for the model heater being
installed to make sure the product is suitable for your
application and the clearances are maintained. Read and
follow the safety guidelines below:
• Keep petrol or other combustible materials including
flammable objects, liquids, dust or vapours away from
this heater or any other appliance.
• Maintain clearances from heat sensitive material,
equipment and workstations.
• Maintain clearances from vehicles parked below the
heater.
• Maintain clearances from swinging doors, overhead
cranes, vehicle lifts, partitions, storage racks, hoists,
etc.
• In locations used for the storage of combustible
materials, signs must be posted to specify the
maximum permissible stacking height to maintain
required clearances from the heater to the combusti-
bles. Signs must be posted adjacent to the heater
thermostat. In the absence of a thermostat, signs
must be posted in a conspicuous location.
• Consult local Building Inspector, Fire Insurance
Carrier or other authorities for approval of proposed
installation when there is a possibility of exposure to
combustible airborne materials or vapours.
• Hang heater in accordance to the minimum suspen-
sion requirements on Page 9, Section 4.6 through
Page 9, Section 4.8.
• If the radiant tubes must pass through the building
structure, be sure that adequate sleeving and fire
stop is installed to prevent scorching and/or fire
hazard.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
BLACKHEAT® INSTALLATION OPERATION AND SERVICE MANUAL
3.2 Clearance Data -
NOTE: 1. All dimensions are from the Tube surface.
2. Clearances B, C and D can be reduced by 50% after 7 m of tubing downstream
from the burner.
3. All measurements are in Millimeters.
FIGURE 2: LINEAR , HORIZONTAL MOUNTS
A
C
A
B
C
D
150
890
150
970
150
970
150
150
1170
1930
1170
150
200
1280
2010
1280
200
1020
1780
1020
1220
1970
1220
1330
2080
1330
B
D
1570
890
1650
970
1650
970
FIGURE 3: LINEAR , ONE SIDE REFLECTOR
A
A
B
C
D
150
230
150
230
150
230
150
230
150
230
150
230
200
230
200
230
C
B
D
1580
1200
1760
1380
1760
1380
1930
1500
2090
1660
2130
1710
2160
1760
2240
1860
FIGURE 4: LINEAR, TWO SIDE REFLECTORS
A
A
B
C
D
150
590
150
640
150
640
150
690
150
820
150
860
200
890
200
C
B
D
1020
2320
1020
1660
590
1810
640
1810
640
1960
690
2110
820
2160
860
2210
890
FIGURE 5: LINEAR, 45° MOUNT
A
A
200
200
200
200
200
200
250
200
250
200
275
200
300
200
300
200
C
B
B
D
C
D
1500
1370
1660
1520
1660
1520
1860
1630
1960
1750
2030
1820
2110
1880
2160
2000
4
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 3: CRITICAL CONSIDERATIONS
NOTE: 1. All dimensions are from the Tube surface.
2. Clearances B, C and D can be reduced by 50% after 7 m of tubing downstream
from the burner.
3. All measurements are in Millimeters.
FIGURE 6: LINEAR , 1 FOOT AND 2 FOOT DECO GRILLE
A
C
A
B
C
D
150
890
150
970
150
970
150
1020
1780
1020
150
1170
1930
1170
150
1220
1970
1220
200
200
1330
2080
1330
1280
2010
1280
B
D
1570
890
1650
970
1650
970
FIGURE 7: LINEAR , PROTECTIVE GRILLE
A
A
B
C
D
150
890
150
970
150
970
150
1020
1780
1020
150
1170
1930
1170
150
1220
1970
1220
200
200
1330
2080
1330
C
1280
2010
1280
B
D
1570
890
1650
970
1650
970
FIGURE 8: LINEAR , VENTING
E
Unvented
Fan
Radiant tubes
F
Vented
E
F
1000
500
1000
500
1000
500
1000
500
1000
500
1000
500
1000
500
1000
500
5
Download from Www.Somanuals.com. All Manuals Search And Download.
BLACKHEAT® INSTALLATION OPERATION AND SERVICE MANUAL
3.3 Clearance Data -U Tube
NOTE: 1. All dimensions are from the Tube surface.
2. Clearances B, C and D can be reduced by 50% after 7 m of tubing downstream
from the burner.
3. All measurements are in Millimeters.
.
FIGURE 9: U-TUBE, HORIZONTAL MOUNT
A
C
A
B
C
D
150
890
150
970
150
970
150
1020
1910
1000
150
1170
1980
1090
150
1220
2050
1150
200
1270
2110
1200
200
B
D
1380
2210
1300
1580
760
1730
940
1730
940
FIGURE 10: U-TUBE, ONE SIDE REFLECTOR
A
A
B
C
D
150
230
150
230
150
230
150
230
150
230
150
230
200
230
200
230
C
B
D
1580
1200
1760
1380
1760
1380
1930
1500
2090
1660
2130
1710
2160
1760
2240
1860
FIGURE 11: U-TUBE, TWO SIDE REFLECTORS
A
C
A
B
C
D
150
590
150
640
150
640
150
690
150
820
150
860
200
890
200
B
D
1020
2320
1020
1660
590
1810
640
1810
640
1960
690
2110
820
2160
860
2210
890
FIGURE 12: U-TUBE, FULL 45° MOUNT
A
B
D
A
B
C
D
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
C
1500
1070
1650
1170
1650
1170
1860
1320
1960
1550
2040
1620
2110
1680
2160
1780
6
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 3: CRITICAL CONSIDERATIONS
NOTE: 1. All dimensions are from the Tube surface.
2. Clearances B, C and D can be reduced by 50% after 7 m of tubing downstream
from the burner.
3. All measurements are in Millimeters.
FIGURE 13: U-TUBE, OPPOSITE 45° TILT
A
C
A
B
C
D
200
1370
1500
560
200
1530
1650
560
200
1530
1650
560
250
1630
1860
560
250
1780
1960
560
275
1830
2040
560
300
1880
2110
560
300
1930
2160
560
B
D
FIGURE 14: U-TUBE, PROTECTIVE GRILLE
A
A
B
C
D
150
890
150
970
150
970
150
1020
1910
1000
150
1170
1980
1090
150
1220
2050
1150
200
200
1380
2210
1300
C
B
D
1270
2110
1200
1580
760
1730
940
1730
940
FIGURE 15: U-TUBE, VENTING
E
Unvented
Fan
Radiant tubes
F
E
F
1000
500
1000
500
1000
500
1000
500
1000
500
1000
500
1000
500
1000
500
Vented
7
Download from Www.Somanuals.com. All Manuals Search And Download.
BLACKHEAT® INSTALLATION OPERATION AND SERVICE MANUAL
SECTION 4: SPECIFICATIONS
4.1 Material Specifications
4.3 Venting Specifications
4.1.1 Combustion and Tubes
4.3.1 Fans
®
BH-15, 20, 25, 30 ............ Model: Torin DSF 133-42
BH-35, 40, 45 .................. Model: Torin DSA 524-202
First 3 meters ALUMI-THERM steel tubing.
Remaining tube 100 mm dia. 16 gauge heat treated
aluminised mild steel.
BH-50
.................. Model: Magnetek JF1G
4.1.2 Reflectors
NS3 H14 aluminium or 1.4016 2R stainless
steel (option)
Consult the manufacturer for availability of alternate fans.
4.2 Heater Specifications
4.3.2 Flue
When fitted, the flue must be 100 mm, or greater in
diameter, and must conform to AS5601/AG601. The flue
must be self supporting. Inlet must be 100 mm diameter.
4.2.1 Sequence Controller
Fully automatic single try direct spark 100% shut off
ignition flame rectification module
4.2.2 Electrical
Rating: 230V, 50 Hz, single phase, 1 amp
Connection: 3 pin moulded plug
4.4 Suspension Specifications
Galvanised straight link welded chain.
Working load of 340 kg (750 lbs)
4.2.3 Gas Supply
Connection: Rc1/2 (1/2" BSP int)
Natural :
Nominal - Inlet 1.13kPa
Maximum - Inlet 5.0kPa
4.5 Controls Specifications
Time switches, thermostats, etc. can be wired into the
electrical supply. External controls supplied as an
optional extra.
ULPG Gas (Propane or Propane/Butanemix):
Nominal - Inlet 2.75kPa
Maximum - Inlet 5.00kPa
8
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 4: Specifications
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
4.6 Linear Heater
Input – kW
15
20
25
30
35
40
45
50
Input – MJ
54
72
90
110
125
138
162
180
Tube Length – mm
Overall Heater Length - mm
Weight – kg
6096
6661
41
20-160
2.5
9144
9709
55
30-210
2.5
9144
9709
55
40-265
3.0
12192
12757
68
50-315 55-370
3.5
12192
12757
68
12192
12757
68
15240
15815
81
15240
15815
81
Heated Area – m2
Minimum Installation
Height* – m
65-420 70-475 80-525
5.0
4.6
5.0
5.0
Recommended Installation
Height* – m
3.0
3.5
3.9
4.2
4.8
5.5
6.7
7.6
4.8 U-Tube Heater
Input – kW
15
20
25
30
35
40
45
50
Input – MJ
54
72
90
110
6363
6941
65
50-315 55-370
4.0
125
6363
6941
65
138
6363
6941
66
162
7998
8465
96
180
7998
8465
96
Tube Length – mm
Overall Heater Length - mm
Weight – kg
3323
3893
39
20-160
2.5
4843
5417
54
30-210
2.8
4843
5417
54
40-265
3.5
Heated Area – m2
Minimum Installation
Height* – m
65-420 70-475 80-525
5.0
5.0
5.0
5.0
Recommended Installation
Height* – m
3.0
3.5
3.9
4.2
4.8
5.5
6.7
7.6
*Heights quoted are from ground level to bottom face of firing tube.
NOTE:- Factory recommended mounting heights are listed above as a guideline. If infra-red heaters are
mounted too low, they may result in heat discomfort. It is generally recommended to observe the
recommended mounting heights to optimize comfort conditions. However, certain applications such as spot
heating, freeze protection, outdoor patio heating or very high ceilings may result in the heaters being
mounted outside of the factory recommended mounting heights. Clearances to combustibles must always be
maintained.
Download from Www.Somanuals.com. All Manuals Search And Download.
BLACKHEAT® INSTALLATION OPERATION AND SERVICE MANUAL
4.9 Burner Specifications
Figure 16: BLACKHEAT® Linear and U-Tube
Reflector
Fan
End View Plan View
Swirler*
100 mm
171 mm
Burner Tube
Heat Exchanger Length
Damper
317 mm
Side View
273 mm
Heat Exchanger Length
Burner Tube
Plan View
100 mm
Fan
U-Tube
Fan Tube
Internal Swirler*
Damper
*Swirler must always be located in Fan Tube
4.9.1 Burner Air Plate
BH15
20
BH20
15
BH25
12
BH30
06
BH35
07
BH40
BH45
11
BH50
10
Marking
071300+
09
4.9.2 Jet Marking
Natural
BH15
#30
BH20
BH25
BH30
BH35
BH40
#3
3.3 mm
BH45
BH50
D
3.8 mm
2.3 mm
#19
#37
4.7 mm
#33
#9
#1
Propane/Butane
#46
3.1 mm
#29
#26
4.9.3 Gas Consumption BH15
54
BH20 BH25
72 90
BH30
110
BH35
125
BH40
138
BH45
162
BH50
180
Natural
[MJ/hr]
ULPG MJ/hrasNaturalGas.Approximatekg/hconsumptionasbelowforreferenceonly.
[1.07]
[1.43]
[1.79]
[2.15]
[2.50]
[2.86]
[3.22]
[3.58]
[kg/h]
4.9.4 Governor Pressure
BH15
BH20
BH25
BH30
BH35
BH40
BH45
BH50
ULPG
AllModels2.60kPa
NaturalGas AllModels0.75kPa
10
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 5: MAJOR COMPONENT DESCRIPTIONS
SECTION 5: MAJOR COMPONENT DESCRIPTIONS
Burner (shown with Tube
Gasket)
Reflector
Must be installed with the
flame observation window
facing down.
(Aluminium or
Stainless Steel)
Alternate overlap as
shown on overview.
Minimum overlap is 18
cm.
Burner Tube
Fan Tube with Internal Swirler
Fan tube is
always the last tube on the heater
where the fan is attached.
Tube
Supplied in 3m lengths. Burner
tube is always the first tube after
the burner.
Heat Treated Aluminized Tube
Supplied in 3m lengths.
Tube and Reflector Hanger
with Tube Clamp Package
Position this hanger no more
than 20cm away from the
burner assembly.
Coupling Assembly
with Lock
Recommended 100mm.
Reflector End Cap
Punch out center section to
accommodate heat exchanger
tube.
Tube and Reflector Hanger
Suspend system from these
hangers.
Fan Assembly (Includes Flange)
Fan Assembly is attached to the last
section of heat exchanger tubing
(Fan Tube).
Reflector Support Strap, Wire
Form & #8 x 3/4 (3.9 x 19mm)
Screw
Damper Flange Assembly
For use on Multiburner Systems.
Flex Gas Line
Fan Flange Assembly
and Screws
Tee
Assembly
Turnbuckle
Adjuster
U-Tube
Assembly
U-Tube
Support
Bracket
Bow
Shackle
11
Download from Www.Somanuals.com. All Manuals Search And Download.
BLACKHEAT® INSTALLATION OPERATION AND SERVICE MANUAL
SECTION 6: GENERAL SUSPENSION DETAILS
WARNING
Suspension Hazard
Hang heater with general purpose welded link steel
chain, 4 mm or larger in diameter, with working
load of 340 Kg.
Failure of the supports can result in death, injury
or property damage.
Step 6.1 Suspension Details
Typical Suspension Details
Screw Hook
min. 10 mm
Concrete
Washer
Beam
Beam
Clamp
Anchor
Locknut
I-Beam
I-Beam
Washer
10 mm
Rod
60 cm
minimum*
Wood
Beam
30 cm
minimum*
Bow
Shackle
Turnbuckle
(not included)
* Allows for thermal expansion of system
Bow Shackle
Hanger
Side View
Hanger
Front View
45° Angle
100 mm
Max.
Description
Burner Tube
Bow Shackle
Tube/Reflector Hanger
Part Number
03051101
E0007576
03090100
12
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 7: LINEAR HEATER INSTALLATION
SECTION 7: LINEAR HEATER INSTALLATION
The figures in this section provide a general overview of
component placement in a BLACKHEAT® Linear
system. The location of some components
such as supports and couplings is crucial for proper
installation. Assemble the heater components as shown
on Page 14, Figure 17.
For optional reflector configurations for Linear heaters
See Page 4, Figure 2 through Page 5, Figure 8. Install
appropriate suspension hardware, beam clamps, chain or
rod at predetermined locations. Adjustments of chain
length will provide uniform pitch.
If any step is unclear, please contact Roberts-Gordon at
+61[3]95612100 [HurllNu-WayPtyLtd]
7.1 Linear Standard Parts List
Part No.
Description
BLACKHEAT® Burner Assembly (Input and Fuel Varies)
1
1
-
1
1
-
1
1
-
1
1
-
1
-
1
-
1
-
1
-
07260001 Fan Package XP 1
07260002 Fan Package XP 2
07260003 Fan PackageXP3
1
-
1
-
1
-
-
-
-
-
-
1
03051101 Burner Tube, 100 mm x 3048 mm
91409408 Tube, 100 mm x 3048 mm
1
-
1
1
1
-
1
1
1
-
1
2
1
-
1
2
1
-
1
2
1
-
1
3
1
-
1
3
S5127W Fan Tube, 100 mm x 3048 mm, with 3048 mm Swirler
S5134W Fan Tube, 100 mm x 3048 mm with 2134 mm Swirler
01329600 Standard Coupling Assembly
1
-
1
4
4
1
1
2
2
2
2
3
3
3
3
3
3
4
4
01329700 Coupling Lock
02750303 Reflector, Aluminium, 2439 mm
3
3
2
2
4
4
2
2
4
4
2
2
6
6
2
2
6
6
2
2
6
6
2
2
7
7
2
2
7
7
2
2
S5163W Reflector, Stainless Steel, 2439 mm (Optional)*
02750800 Reflector End Cap, Aluminium
C2332B Reflector End Cap, Stainless (Optional)*
03090100 Tubeand Reflector Hanger
3
1
2
4
2
4
1
3
6
3
4
1
3
6
3
5
1
5
1
5
1
6
1
6
1
01318901 Tube Clamp Package (including Nut, Washer & Bolt)
91908004 WireForm
5
5
5
6
6
94320812 Screw #8 x 3/4 (3.9 x 19mm), (goes with 91908004)
03050000 Reflector Support Strap
10
5
10
5
10
5
12
6
12
6
E0007576 Bow Shackle
3
1
4
1
4
1
5
1
5
1
5
1
6
1
6
1
91107720 U-Clip Package (20 Pieces)
* PVC coating must be removed prior to installation.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
BLACKHEAT® INSTALLATION OPERATION AND SERVICE MANUAL
Figure 17: BLACKHEAT® Linear General Assembly Overview
14
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 7: LINEAR HEATER INSTALLATION
Figure 18: BLACKHEAT® Linear Layout Overviews-[BH55NotAvailable]
b
b
c
c
LEGEND
g
d
e
Burner Box
BH15ST
f
Reflector
Tube
*Loose
Screw
Tight
Screw
b
b
Tube/Reflector
Hanger
c
c
g
d
e
e
Reflector Support
Coupling Assembly
BH20ST
BH25ST
f
Fan Assembly
*Loose
Screw
*Loose
Screw
Tight
Screw
b
b
c
c
Damper Assembly
g
d
e
e
e
BH30ST
BH35ST
BH40ST
f
Reflector
*Loose
Screw
*Loose
Screw
*Loose
Screw
Tight
Screw
Tight
Screw
b
b
c
c
g
d
e
e
e
e
*Loose Screws -
loosened
2 mm (1/16")
to allow slippage.
BH45ST
BH50ST
f
*Loose
Screw
*Loose
Screw
*Loose
Screw
Tight
Screw
Tight
Screw
Tight
Screw
b
b
c
c
g
d
e
e
e
e
e
BH55ST
f
*Loose
Screw
*Loose
Screw
*Loose
Screw
*Loose
Screw
Tight
Screw
Tight
Screw
Tight
Screw
a = reflector width (not shown)
b = end cap to burner/fan
c = end cap to hanger
e = distance typical between hangers
f = burner height
g = burner length
d = distance first hanger
Reflector
Overlap
(approx.)
Model
a
b
c
d
e
f
g
700 mm
250 mm
250 mm
530 mm
530 mm
530 mm
330 mm
330 mm
200 mm
365 mm
365 mm
365 mm
365 mm
365 mm
365 mm
365 mm
365 mm
365 mm
50 mm
50 mm
2290 mm
2290 mm
2290 mm
2290 mm
2290 mm
2290 mm
2290 mm
2290 mm
2290 mm
3050 mm
3050 mm
3050 mm
3050 mm
3050 mm
3050 mm
3050 mm
3050 mm
3050 mm
366 mm
366 mm
366 mm
366 mm
366 mm
366 mm
366 mm
366 mm
366 mm
291 mm
291 mm
291 mm
291 mm
291 mm
291 mm
291 mm
291 mm
291 mm
BH15
50 mm
50 mm
50 mm
50 mm
50 mm
50 mm
50 mm
50 mm
50 mm
50 mm
50 mm
50 mm
50 mm
50 mm
50 mm
50 mm
BH20..
BH25
BH30..
BH35
BH40..
BH45
BH50..
BH55
15
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 7: LINEAR HEATER INSTALLATION
Step 7.3 Burner Tube Installation
NOTE:
Offset mounting
hole must be
to the top
Tubing requires a downward
slope of 13 mm
End View
per 6 m away
from burner.
Bow Shackle
Hanger
Bottom
of Tube
Weld
Seam
Burner Tube
229 cm ± 25cm
Description
Burner Tube
Bow Shackle
Tube/Reflector Hanger
Part Number
03051101
E0007576
03090100
Step 7.4 Coupling and Tube Assembly
Start Slidebar/Coupling Lock
onto coupling
Close coupling
A with tab
B
Tab
Slidebar
Wide end
Coupling
Open
8 cm to
10 cm
Closed
Tighten coupling to join tubes
Insert tubes into coupling
D
C
Slidebar
Coupling
Orient coupling so that
the impact block is in the
2:00 or 10:00 oclock
positions
Tube
Tube
Description
Coupling
Slidebar/Coupling Lock
Tube
Part Number
Tube
01329600
01329700
91409408
19
Download from Www.Somanuals.com. All Manuals Search And Download.
BLACKHEAT® INSTALLATION OPERATION AND SERVICE MANUAL
Step 7.4.1 Coupling and Tube Assembly (Continued)
WARNING
Tighten slidebar as shown below.
Tubes will fall down if slidebar is incorrect.
Failure to follow these instructions can result in death,
injury or property damage.
Drive Slidebar until tight.
End of slidebar should be
within tolerance listed below.
± 5 cm
Correct slidebar
dimensions
Incorrect slidebar
position
• Repeat Step 7.4 A - D until all tubes are assembled, See Page 20, Section 7.4.2 shown below.
Step 7.4.2 Coupling and Tube Assembly (Continued)
Heat Exchanger
Overall Tubing Length (m) of Tubes
Number
Model
BH15
BH20
BH25
BH30
BH35
BH40
BH45
BH50
6
9
9
12
12
12
15
15
2
3
3
4
4
4
5
5
229 cm
± 25 cm
305 cm Typ
± 25 cm
Total Overall
Tube Length
20
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 7: LINEAR HEATER INSTALLATION
Step 7.5 Tube Clamp Package Installation
Bolt
Tube Clamp
Flat
W
asher
Nut
(Torque 13.56 Nm
120 in lb)
Description
Tube Clamp
Bolt
Flat Washer
Nut
Part Number
01396801
97113940
95211600
92113900
Step 7.6 Reflector Installation
Hanger
Burner Tube
Reflector
Description
Part Number
Tube/Reflector Hanger
Burner Tube
Reflector
03090100
03051101
02750303
21
Download from Www.Somanuals.com. All Manuals Search And Download.
BLACKHEAT® INSTALLATION OPERATION AND SERVICE MANUAL
Step 7.6.1 Reflector Installation (Continued)
Wire Form
Reflector
Reflector
End Cap
Sheet Metal
Screw
Tube
Reflector Support
Strap
U-Clips
Description
Reflector Support Package
Wire Form
Reflector Support Strap
Screw #8 x 3/4 (3.9 x 19mm)
U-Clip Package
Part Number
03050010
91908004
03050000
94320812
91107720
027508XX
U-Clip
(2 clips per alternate
overlaps per side-
see Figure 21)
Reflector End Cap
Figure 21: Reflector Overlap Detail
Reflector
Reflector
Tight
screws
Loose screws
loosened 2 mm (1/16")
to allow slippage.
Loose
screws
No
U-Clips
Install
U-Clips
No
U-Clips
Install
U-Clips
Tight
screws
18 cm (7")
Minimum
18 cm (7")
Minimum
Install one reflector
support per reflector
as needed.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
BLACKHEAT® INSTALLATION OPERATION AND SERVICE MANUAL
SECTION 8: U-TUBE HEATER INSTALLATION
The figures in this section provide a general overview of
component placement in a BLACKHEAT® U-Tube
system. The location of some components such as
supports and couplings is crucial for proper installation.
appropriate suspension hardware, beam clamps, chain or
rod at predetermined locations. Adjustments of chain
length will provide uniform pitch.
If any step is unclear, please contact Roberts-Gordon at
Assemble the heater components as shown on Page 14, +44 (0) 1902 494425or+61 [3]9561 2100
Figure 17.
For optional reflector configurations for U-tube heaters
See Page 6, Figure 9 through Page 7, Figure 15. Install
8.1 U-Tube Standard Parts List
Part No.
Description
BLACKHEAT® Burner Assembly (Input and Fuel Varies)
1
1
-
1
1
-
1
1
-
1
1
-
1
-
1
-
1
-
1
-
07260001 Fan Package XP1
07260002 Fan Package XP2
07260003 Fan Package XP3
1
-
1
-
1
-
-
-
-
-
-
1
03051101 Burner Tube, 100 mm x 3048 mm
91409408 Tube, 100 mm x 3048 mm
1
-
1
-
1
-
1
2
-
1
2
-
1
2
-
1
2
2
1
-
1
2
2
91409423 Tube, 100 mm x 1524 mm
-
2
1
-
2
1
-
S5127W Fan Tube, 100 mm x 3048 mm, with 3048 mm Swirler
S5134W Fan Tube, 100 mm x 3048 mm with 2134 mm Swirler
01335901 U-Bend
1
-
1
-
1
-
1
-
1
1
6
6
1
2
2
1
4
4
1
4
4
1
4
4
1
4
4
1
4
4
1
6
6
01329600 Standard Coupling Assembly
01329700 Coupling Lock
02750303 Reflector, Aluminium, 2439 mm
4
4
4
4
4
4
4
4
4
4
4
4
6
6
4
4
6
6
4
4
6
6
4
4
8
8
4
4
8
8
4
4
S5134W Reflector, Stainless Steel, 2439 mm (Optional)*
02750800 Reflector End Cap, Aluminium
C2332B Reflector End Cap, Stainless (Optional)*
03090100 Tubeand Reflector Hanger
01318901 Tube Clamp Package (including Nut, Washer & Bolt)
91908004 WireForm
4
1
2
2
1
6
1
4
4
1
6
1
4
4
1
6
1
4
4
1
6
1
4
4
1
6
1
4
4
1
8
1
6
6
1
8
1
6
6
1
03050000 Reflector Support Strap
03020501 U-Bend Support Bracket
E0007576 Bow Shackle
4
2
2
6
6
4
6
2
2
6
6
8
6
2
2
6
6
8
6
2
2
6
6
8
6
2
2
6
6
8
6
2
2
6
6
8
8
2
8
2
91107720 U-Clip Package (20 Pieces)
91912501 U-Bolt M6
2
2
C0090B Nut M6
6
6
96411500 Lockwasher 6mm
6
6
94320812 Screw #8 x 3/4 (3.9 x 19mm), (goes with 91908004)
S7199K Damper Flange Assembly (For use on Multiburner Systems)
12
12
1 Per Heater
*PVC coating must be removed prior to installation.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 8: U-TUBE HEATER INSTALLATION
Figure 22: BLACKHEAT® BH15UT Assembly Overview
25
Download from Www.Somanuals.com. All Manuals Search And Download.
BLACKHEAT® INSTALLATION OPERATION AND SERVICE MANUAL
Figure 23: BLACKHEAT® U-Tube Layout Overviews
b
c
LEGEND
g
d
Burner Box
BH15
h
Reflector
Tube
*Loose
Screw
Tube/Reflector
Hanger
b
c
Reflector Support
Coupling Assembly
U-Tube
g
g
g
d
f
BH20
BH25
h
*Loose
Screw
Tight
Screw
b
c
Reflector
d
e
BH30
BH35
BH40
*Loose Screws -
h
loosened
2 mm (1/16")
to allow slippage.
*Loose
Screw
Tight
Screw
b
c
d
e
f
BH45
BH50
h
*Loose
Screw
*Loose
Screw
Tight
Screw
a = overall width (not shown)
b = end cap to burner/fan
c = end cap to hanger
d = distance first hanger
g = burner length
h = burner height
e = distance typical between hangers
f = distance between last full tube
hanger and half tube hanger
Reflector
Overlap
(approx.)
Model
a
b
c
d
e
f
g
1780 mm
250 mm
250 mm
580 mm
580 mm
580 mm
690 mm
690 mm
850 mm
850 mm
850 mm
850 mm
850 mm
850 mm
850 mm
850 mm
50 mm
50 mm
50 mm
50 mm
50 mm
50 mm
50 mm
50 mm
50 mm
50 mm
50 mm
50 mm
50 mm
50 mm
50 mm
50 mm
2290 mm 3050 mm
2290 mm 3050 mm
2290 mm 3050 mm
2290 mm 3050 mm
2290 mm 3050 mm
2290 mm 3050 mm
2290 mm 3050 mm
2290 mm 3050 mm
366 mm
366 mm
366 mm
366 mm
366 mm
366 mm
366 mm
366 mm
291 mm
291 mm
291 mm
291 mm
291 mm
291 mm
291 mm
291 mm
BH15
BH20....
BH25
BH30....
BH35
BH40....
BH45
BH50....
26
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 8: U-TUBE HEATER INSTALLATION
Step 8.2 Critical Hanger Placement
Spreader
Bar
Bow
Shackle
NOTE: Spreader bar must be used on
single suspension point installations.
Do not hang heater from spreader bar.
Threaded
Bar
Suspension
Bow
Shackle
Chain
Washers
Suspension
Bolt
Chain
(Torque:
13.5 Nm
129 in lb)
Tube and Reflector
Hanger
Optional
Hanging
Configuration
Tube and Reflector
Hanger
First Tube and
Reflector Hanger
229 cm ± 25cm
See Assembly
Drawing
Description
Part Number
Bow Shackle
Tube/Reflector Hanger
Spreader Bar
E0007576
03090100
07260010
Step 8.3 Burner Tube and Fan Tube Installation
Offset mounting
hole must be
to the top
End View
Fan Tube
Bottom
of Tube
Weld
Burner Tube
Description
Burner Tube
Fan Tube
Part Number
03051100
S5127W
27