Rheem Water Heater GAS BOOSTED SOLAR WATER HEATER User Guide

“Streamline Closed Circuit”  
GAS BOOSTED  
SOLAR WATER HEATER  
OWNER’S MANUAL  
AND  
WARRANTY / INSTALLATION INFORMATION  
WARNING: Plumber – Be Aware  
Use copper pipe ONLY. Plastic pipe MUST NOT be used.  
It is a requirement of a solar water heater installation that all  
pipe work be in copper and not plastic, due to the effects of  
high water temperatures.  
Solahart Industries Pty Ltd  
ABN 45 064 945 848  
This water heater must be installed and serviced by an authorised person.  
Please leave this guide with the householder.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTENTS  
HOUSEHOLDER – We recommend you read pages 5 to 16.  
The other pages are intended for the installer but may be of interest.  
About Your Water Heater............................................................................................. 5  
How Your Water Heater Works.................................................................................. 10  
Regular Care ............................................................................................................... 12  
Save A Service Call .................................................................................................... 13  
Installation – Solar Storage Tank.............................................................................. 17  
Installation – Solar Collectors ................................................................................... 26  
Connections – Plumbing............................................................................................ 29  
Connections – Electrical............................................................................................ 33  
Commissioning........................................................................................................... 35  
Draining The Water Heater......................................................................................... 51  
Water Supplies............................................................................................................ 52  
Warranty ...................................................................................................................... 53  
Solahart Offices .......................................................................................................... 56  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
Congratulations on choosing a “STREAMLINE CLOSED CIRCUIT GAS BOOSTED” solar water heater.  
We are confident that your purchase will provide you many years of trouble free hot water.  
All over the world, the Solahart name is synonymous with quality in water heating. From humble  
beginnings in the pioneering days of Western Australia, a reputation has been built up over nearly a  
century.  
In 1905, two enterprising plumbers formed the company known as S. W. Hart, a name that was  
retained for over 70 years. Even in its early stages, S. W. Hart was involved in the manufacture of metal  
products for water storage and water heating. Since 1953, S. W. Hart, now Solahart Industries Pty Ltd,  
has been producing thermosyphon solar hot water systems, which is well over 40 years of hot water  
experience.  
Solahart is the market leader in Australia and a dominant brand throughout the world. Our network of  
distributors covers over 70 countries in Europe, North America, Africa and Asia. In our home market of  
Australia, we offer the widest range of thermosyphon solar water heater products, and we are now  
releasing the “STREAMLINE CLOSED CIRCUIT GAS BOOSTED” active solar hot water system. Our  
product is positioned within the hot water market as a reliable, durable product with state of the art  
manufacturing technology.  
It is with the above in mind that we at Solahart Industries Pty Ltd are confident that your purchase of the  
“STREAMLINE CLOSED CIRCUIT GAS BOOSTED” solar water heater will provide you reliable hot  
water with quality after sales service back up.  
Thankyou  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ABOUT YOUR WATER HEATER  
MODEL TYPE  
Congratulations for choosing a Solahart® water heater. Your Solahart Streamline closed circuit solar  
water heater is designed for the solar collectors to be roof mounted and the solar storage tank to be  
installed at ground or floor level. The solar storage tank is suitable for outdoor installation only and with  
either Solahart ‘J’ or ‘KF’ solar collectors. The system is suitable for installation in areas subject to frost  
or freeze conditions. Freeze conditions occur below 6°C.  
HOW HOT SHOULD THE WATER BE?  
The solar control unit will circulate the closed circuit fluid through  
typical maximum  
temperature from solar  
the solar collectors until a temperature of approximately 75°C is  
reached in the solar storage tank. During periods of low solar  
gain  
energy gain, the gas booster will boost the water temperature  
automatically to a minimum 60°C when required.  
booster setting and  
minimum recommended  
Note: The preset outlet booster temperature setting of the gas  
stored water temperature  
booster cannot be adjusted by the householder. The setting can  
only be adjusted by your nearest Solahart Dealer. The preset  
outlet booster temperature setting of the gas booster is 60°C.  
maximum recommended  
supply temperature to  
bathrooms and ensuites  
To meet the requirements of the National Plumbing Standard the  
temperature setting must not be below 60°C.  
Warning: Temperature controllers must not be fitted to this  
water heater as part of a solar water heater system because  
water at a temperature much higher than the controller setting  
can be delivered.  
HOTTER WATER INCREASES THE RISK OF SCALD INJURY  
This water heater can deliver water at temperatures which can cause scalding. Check the water  
temperature before use, such as when entering a shower or filling a bath or basin, to ensure it is  
suitable for the application and will not cause scald injury.  
We recommend and it may also be required by regulations that an approved temperature limiting  
device be fitted into the hot water pipe work to the bathroom and ensuite when this water heater is  
installed. This will keep the water temperature below 50°C at the bathroom and ensuite. The risk of  
scald injury will be reduced and still allow hotter water to the kitchen and laundry.  
This water heater has two outlets. One is a hot water outlet and the other is a tempered water outlet.  
The purpose of the hot water outlet is to deliver hot water at between 60°C and 75°C, usually for  
kitchen and laundry use. The purpose of the tempered water outlet is to deliver water up to 50°C,  
usually for bathroom or ensuite use.  
WARNING  
This water heater is not intended to be operated, adjusted or tampered with by young children or infirm  
persons. Young children should be supervised to ensure they do not interfere with the water heater.  
The water heater uses 240 V AC electrical power for operation of the control systems and the  
electrically operated components. The removal of the front covers will expose 240 V wiring. They must  
only be removed by an authorised or qualified person.  
The power lead from the water heater must be plugged into a weatherproof electrical outlet. Take care  
not to touch the power plug with wet hands.  
Care should be taken not to touch the pipe work connecting the solar storage tank and the solar  
collectors. Very high temperature closed circuit fluid can be generated by the solar collectors under  
certain conditions and flow through the pipe work from the solar collectors to the solar storage tank.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
ABOUT YOUR WATER HEATER  
SAFETY  
This water heater is supplied with temperature sensors, a FlameSafe™ protection system, pressure  
relief valves and a combination temperature pressure relief valve. These devices must not be tampered  
with or removed. The water heater must not be operated unless each of these devices is fitted and is in  
working order.  
If the power supply cord or plug to the solar storage tank is damaged, it must be replaced by an  
authorised person in order to avoid a hazard. The power supply cord and plug must be replaced with a  
genuine replacement part available from Solahart. Phone your nearest Solahart Dealer to arrange for  
an inspection.  
The warranty can become void if relief valves or other safety devices are tampered with or if the  
installation is not in accordance with these instructions.  
Do not store flammable or combustible materials near the  
water heater. Flammable liquids (such as petrol),  
newspapers and similar articles must be kept well away  
from the water heater and the flue terminal.  
Do not use aerosols, stain removers and household  
chemicals near the water heater whilst it is working. Gases  
from some aerosol sprays, stain removers and household  
chemicals become corrosive when drawn into a flame.  
Do not store swimming pool chemicals, household  
cleaners, etc., near the water heater.  
Do not place anything on top of the water heater or in  
contact with the flue terminal. Ensure the flue terminal is not  
obstructed in any way at any time.  
Do not use Propane / Butane gas mixtures in a Propane model. A Propane model is designed to  
operate on Propane only. The use of Propane / Butane mixture, such as automotive LPG fuel, in a  
Propane model is unsafe and can cause damage to the water heater.  
TO TURN OFF THE WATER HEATER  
If you plan to be away from home for a few nights, we suggest you leave the water heater switched on.  
If it is necessary to turn off the water heater:  
Switch off the electrical supply at the power outlet to the solar storage tank if there is no risk of  
freezing conditions occurring (refer to note below).  
Close the gas isolation valve at the inlet to the water heater.  
Close the cold water isolation valve at the inlet to the water heater.  
Note: If there is a risk of freezing conditions, the electrical supply to the water heater should not be  
switched off unless the gas booster is drained, otherwise damage could result (refer to “Freeze  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ABOUT YOUR WATER HEATER  
TO TURN ON THE WATER HEATER  
Screw in the drain plugs at the cold water inlet and hot water outlet of the gas booster if the gas  
booster has been drained.  
Open the cold water isolation valve fully at the inlet to the water heater.  
Open all of the hot water taps in the house (don’t forget the shower).  
Air will be forced out of the taps.  
Close each tap as water flows freely from it.  
Open the gas isolation valve fully at the inlet to the water heater.  
Plug in the water heater at the power outlet and switch on the electrical supply.  
The power outlet must be switched on for the solar controls to operate and solar gain to be  
achieved and for the gas booster to operate.  
The gas booster will operate automatically when you open a hot tap, if boosting is required.  
HOW DO I KNOW IF THE WATER HEATER IS INSTALLED CORRECTLY?  
Installation requirements are shown on page 25. The water heater must be installed by an authorised  
person and the installation must comply with National Standards AS/NZS 3500.4, AS 5601,  
AS/NZS 3000 and all local codes and regulatory authority requirements. In New Zealand, the  
installation must conform with the New Zealand Building Code.  
Temperature controllers must not be fitted (refer to warning under “How Hot Should The Water Be?”  
on page 5).  
PIPE WORK AND INSULATION  
The solar hot and solar cold pipe work between the solar storage tank and the solar collectors  
MUST BE of copper and fully insulated with closed cell polymer insulation or similar (minimum  
thickness 13 mm). The insulation must be weatherproof and UV resistant if exposed. The insulation will  
offer corrosion protection to a metal roof against water runoff over the copper pipe, assist in avoiding  
accidental contact with the solar pipe work and also reduce pipe heat losses.  
The insulation must be fitted up to the connections on both the solar collectors and the solar storage  
tank, as very high temperature closed circuit fluid can flow from the solar collectors to the solar storage  
tank under certain conditions.  
There must be a continuous fall in the pipe work from the solar collectors to the solar storage tank. The  
continuous fall is essential to assist in the drain back function of the solar system.  
Plastic pipe MUST NOT be used, as it will not withstand the temperature of the closed circuit fluid  
generated by the solar collectors under certain conditions (refer to Warning on page 28).  
RAIN WATER TANK  
If the solar collectors and solar pipe work are installed on a section of roof which is part of a rain water  
runoff collection system, then it is recommended this section of roof and its gutter be isolated from the  
rain water collection system. The gutter should be isolated to a width greater than the solar collectors  
and pipe work and must have suitable drainage. This is to ensure in the event of a leak from the solar  
collectors or pipe work, a rainwater tank cannot be contaminated with closed circuit fluid.  
The closed circuit fluid contains food grade additives (rust inhibitor and anti-freeze agent), is non-toxic  
and is harmless to the environment. However, if it enters a rain water tank, it can kill off microscopic  
algae which are typically present in the water causing an unpleasant odour to develop and resulting in  
the rain water tank having to be drained and cleaned.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
ABOUT YOUR WATER HEATER  
DOES THE WATER QUALITY AFFECT THE WATER HEATER?  
The water heater is suitable for most public water supplies, however some water qualities may have  
detrimental effects on the cylinder, gas booster heat exchanger and fittings. If you are in a known  
harsh water area you must read page 52. If you are not sure, have your water quality checked  
against the conditions described on page 52.  
HOW LONG WILL THE WATER HEATER LAST?  
There are a number of factors that will affect the length of service the water heater will provide. These  
include the water quality, the water pressure, temperature (inlet and outlet) and the water usage  
pattern. However, your Solahart water heater is supported by a comprehensive warranty (refer to  
ANODE PROTECTION  
The anode(s) installed in your water heater will slowly dissipate whilst protecting the cylinder. The life of  
the water heater cylinder may be extended by arranging for an authorised person to inspect the  
anode(s) and replace if required.  
The suggested time after installation when the anode(s) should be inspected is 8 years.  
For softened water supplies or in areas of poor water quality, it is recommended the anode(s) be  
inspected 3 years earlier than shown (refer to “Water Supplies” on page 52).  
FREEZE PROTECTION  
Solar Circuit  
The solar circuit must be installed with a continuous fall in the pipe work from the solar collectors to the  
solar storage tank, the solar hot and solar cold pipes must be fully insulated with closed cell polymer  
insulation (minimum thickness 13 mm) and the system charged with correctly mixed closed circuit fluid  
to offer protection against freeze damage. The system has NO WARRANTY for freeze damage if there  
is not a continuous fall in the solar hot and solar cold pipes, or they are uninsulated, or the closed circuit  
fluid has been incorrectly mixed (refer to “Warranty Exclusions” on page 53).  
The anti freeze control of the solar circuit is designed so there is no closed circuit fluid in the solar  
collectors or solar cold and solar hot pipes when the pump is off.  
Gas Booster Water Heater  
The gas booster has a frost protection system. The frost protection system will protect the gas booster  
from damage, by preventing ice forming in the waterways of the gas booster, in the event of freezing  
conditions occurring.  
Notes:  
The gas booster frost protection system will be rendered inoperable if electrical power is not  
available at the water heater. Damage caused by freezing due to the unavailability of power at the  
water heater is not covered by warranty (refer to “Warranty Exclusions” on page 53).  
If it is necessary to switch the power off to the water heater and there is a risk of freezing, then it is  
necessary to drain the gas booster (refer to “Draining the Gas Booster Water Heater” on page 9).  
Pipe work to and from the water heater must be adequately insulated to prevent freezing.  
The water heater is not suitable for installation in areas where the ambient temperature falls below -  
20ºC (including wind chill factor).  
Refer to “Warranty Exclusions” on page 53.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ABOUT YOUR WATER HEATER  
DRAINING THE GAS BOOSTER WATER HEATER  
Turn off the water heater (refer to “Turn Off The Water Heater” on page 6).  
Open a hot tap (preferably the shower outlet).  
Unscrew the two drain plugs, one each at the cold water inlet and hot water outlet, on the  
underside of the water heater.  
Water will drain from the water heater.  
When water stops flowing from the water heater, close the hot tap.  
Note: It is recommended not to screw the drain plugs back in, until the water heater is to be turned on  
again.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
HOW YOUR WATER HEATER WORKS  
SOLAR OPERATION  
The Solahart Streamline closed circuit solar water heater has its vitreous enamel lined solar storage  
tank installed at ground or floor level, remotely from the solar collectors. This water heater is an indirect  
solar hot water system with a heat exchanger in the solar storage tank. The heat exchanger is filled with  
closed circuit fluid and is connected to the solar collectors forming a closed circuit.  
As the sun heats the solar collectors, the increase in temperature activates the pump. The pump  
switches on whenever the solar collectors are hotter than the water in the tank. The pump moves the  
closed circuit fluid from the solar storage tank heat exchanger through an insulated copper pipe to the  
solar collectors to be heated by the sun’s energy and then back to the heat exchanger. Heat transfers  
from the closed circuit fluid in the heat exchanger to the water stored in the solar storage tank.  
This process continues while solar energy is available and until the water in the solar storage tank  
reaches a temperature of approximately 75°C. The pump is then deactivated and the closed circuit fluid  
in the solar collectors and solar pipe work drains back into the heat exchanger in the solar storage tank.  
The closed circuit provides protection to the solar collectors and solar circuit in harsh water areas. The  
drain back principle provides protection to the system in freezing conditions.  
Automatic safety controls are fitted to the water heater to provide safe and efficient operation.  
GAS BOOSTING OPERATION  
Water stored in the solar storage tank passes through the gas  
booster when a hot tap is opened. The gas booster is for heating  
the water at times of low solar energy gain, such as during cloudy  
or rainy weather, or during winter months.  
Solar heated water can reach temperatures up to 75°C in the solar  
storage tank. When the solar heated water temperature is above  
58°C, the gas booster will not boost the water temperature.  
The gas booster operates automatically if heating of the water is  
required. When the solar heated water temperature is below 58°C,  
the gas burners ignite to provide immediate heating of the water to  
a minimum temperature of 60°C. The heat produced by the burner  
is transferred to the water through the heat exchanger. The water is  
heated to a constant temperature by the automatic adjustment of  
the gas supply to the burner to suit the water flow rate. The gas  
burners extinguish when the hot tap is closed.  
Automatic safety controls are fitted to the water heater to provide safe and efficient operation.  
WATER OUTLET TEMPERATURE  
This water heater has two outlets. One is a hot water outlet and the other is a tempered water outlet.  
The purpose of the hot water outlet is to deliver hot water at between 60°C and 75°C, usually for  
kitchen and laundry use. The purpose of the tempered water outlet is to deliver water up to 50°C,  
usually for bathroom or ensuite use.  
The tempered water outlet is from the tempering valve, located under the pipe cover at the front of the  
water heater immediately below the gas booster. The tempering valve is the brass valve with a green  
plastic cap. The tempering valve mixes hot water from the solar storage tank and gas booster with cold  
water from the mains supply and delivers tempered water from its outlet.  
The hot water outlet is located above the tempering valve. Depending upon how the water heater was  
installed, either both or only one of these outlets may have been plumbed to the hot water pipe work in  
the premises.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
HOW YOUR WATER HEATER WORKS  
MAINS PRESSURE  
The water heater is designed to operate at mains pressure by connecting directly to the mains water  
supply. If the mains supply pressure in your area exceeds that shown on page 19, a pressure limiting  
valve must be fitted. The supply pressure should be greater than 350 kPa for true mains pressure  
operation to be achieved. The supply pressure should be greater than 140 kPa for the rated flow and  
performance of the gas booster to be achieved.  
GOING ON HOLIDAYS  
It is not necessary to switch off the electrical supply at the power outlet to the water heater if you are  
going away. However, if it is necessary to switch off the power to the water heater, refer to “To Turn Off  
The Water Heater” on page 6. If the power to the water heater is switched off and there is a risk of  
freezing, then it is necessary to drain the gas booster (refer to “Draining the Gas Booster Water Heater”  
on page 9)  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
REGULAR CARE  
TEMPERATURE PRESSURE RELIEF VALVE  
This valve is near the top of the water heater and is essential for its safe operation. It is possible for the  
valve to release a little water through the drain line during each heating period. This occurs as the water  
is heated and expands by approximately 1/50 of its volume.  
Continuous leakage of water from the valve and its drain line may indicate a problem with the water  
WARNING: Never block the outlet of this valve or its drain line for any reason.  
Operate the easing lever on the temperature pressure relief  
valve once every six months. It is very important you raise  
and lower the lever gently.  
WARNING: Failure to do this may result in the water heater  
cylinder failing.  
If water does not flow freely from the drain line when the lever is  
lifted, then the water heater should be checked by your nearest  
Solahart Dealer.  
The temperature pressure relief valve should be checked for  
performance or replaced at intervals not exceeding 5 years, or  
more frequently in areas where there is a high incidence of water  
EXPANSION CONTROL VALVE  
In many areas, including South Australia, Western Australia and  
scaling water areas, an expansion control valve is fitted to the  
cold water line to the water heater. Water will flow from its drain  
line during the heating period.  
water  
heater  
Operate the easing lever on the expansion control valve once  
every six months. It is very important you raise and lower the  
lever gently. The expansion control valve should be checked for  
performance or replaced at intervals not exceeding 5 years, or  
more frequently in areas where there is a high incidence of water  
deposits.  
lift until water  
flows from the  
drain line –  
drain  
line  
lower gently  
COLLECTOR GLASS  
Ensure the glass on your solar collectors is free of dust, salt spray or any other matter, which may  
reduce the effectiveness of the solar collectors. If the collector glass becomes dirty, hose down or if the  
solar collectors are accessible, wash the collector glass with water and a soft brush when the solar  
collectors are cool. Have any trees trimmed which may shade the solar collectors.  
GENERAL MAINTENANCE  
The jacket of the water heater can be cleaned with a soft cloth and warm mild soapy water. Under no  
circumstances should abrasive materials or powders be used.  
SERVICING  
For safe and efficient operation, the water heater should be serviced annually by your nearest Solahart  
Dealer. Only genuine replacement parts should be used on this water heater.  
Warning: Servicing of the water heater should only be carried out by authorised personnel.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
SAVE A SERVICE CALL  
Check the items below before making a service call. You will be charged for attending to any condition  
or fault that is not related to manufacture or failure of a part.  
COLD WATER FROM THE HOT TAP  
Close the hot tap, wait 10 seconds and open the hot tap again.  
Is the hot tap open enough? The gas booster burners will not light if the flow rate is less than  
3.0 L / min.  
Solar control unit and gas booster not operating  
ƒ
Check the power supply cord is plugged in and the  
power outlet switched on.  
ƒ
Is power available in the house? Try using another  
electrical appliance.  
Gas supply  
ƒ
ƒ
Is the isolation valve in the gas line open?  
Is there a gas supply to the rest of the house? Try  
lighting another gas appliance.  
ƒ
Has the gas line been purged of air after installation?  
Refer to your plumber.  
NO WATER FROM THE HOT TAP  
No flow of water from the hot tap may indicate a restriction in or failure of the cold water supply to the  
water heater. Check for water flow at other taps and that the cold water isolation valve (refer to  
GAS BOOSTER OPERATING TOO FREQUENTLY  
You may find that the gas booster operates more frequently than expected. This will occur when the  
solar preheat water temperature is lower than 58°C, which may be experienced during periods of low  
solar energy gain or if there has been heavy hot water usage. Factors to consider are:  
Insufficient sunlight  
Insufficient sunlight due to cloudy weather during summer months or low solar energy contribution  
in winter months may mean the gas booster operates more often.  
Collectors shaded  
If trees or other objects shade the solar collectors or if the glass is dirty, the effectiveness of the  
solar collectors will be greatly reduced. Have the trees trimmed or the solar collectors relocated if  
the obstruction is permanent or clean the collector glass (refer to “Collector Glass” on page 12).  
Collector area is too small  
For most installations, the number of solar collectors recommended in Solahart literature has been  
proven to provide the required solar energy to meet the average family needs. However, in some  
circumstances, it may be necessary to install an additional solar collector.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
SAVE A SERVICE CALL  
Are you using more hot water than you think?  
Is one outlet (especially the shower) using more hot water than you think?  
Very often it is not realised the amount of hot water used, particularly when showering. Carefully  
review the family’s hot water usage. As you have installed an energy saving appliance, energy  
saving should also be practised in the home. Adjust your water usage pattern to take advantage of  
maximum solar gains.  
Have your plumber install a flow control valve to each shower outlet, basin and sink to reduce water  
usage.  
Temperature pressure relief valve running  
Is the relief valve discharging too much water? (Refer to “Temperature Pressure Relief Valve  
Water heater size  
Do you have the correct size water heater for your requirements? The sizing guide in the sales  
literature and on the Solahart website (www.Solahart.com.au) suggests average sizes that may be  
needed.  
WATER FLOW FLUCTUATES  
More than one or two hot taps in use at the same time may cause a decrease in the hot water flow from  
the taps.  
Is there more than one or two hot taps open, or are appliances such as a dishwasher or washing  
machine, in use at the same time?  
Ensure only one or two hot taps (or appliance) are on at the one time.  
Check the flow of the water from one tap, eg, the shower.  
The shower should be adjusted so the hot tap is fully open.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAVE A SERVICE CALL  
TEMPERATURE PRESSURE RELIEF VALVE RUNNING  
Normal Operation  
It is normal and desirable this valve allows a small quantity  
of water to escape during the heating cycle. However, if it  
discharges more than a bucket full of water in 24 hours,  
there may be another problem.  
Continuous dribble  
Try gently raising the easing lever on the relief valve for a  
few seconds (refer to “Temperature Pressure Relief Valve”  
on page 12). This may dislodge a small particle of foreign  
matter and clear the fault. Release the lever gently.  
Steady flows for long period (often at night)  
This may indicate the mains water pressure sometimes rises  
above the designed pressure of the water heater. Ask your  
installing plumber to fit a pressure limiting valve.  
NEVER replace the relief valve with one of a higher pressure rating.  
Heavy flows of hot water until the water heater is cold - then stops until water reheats  
The water heater must be switched off at the isolating switch or switchboard. Phone your nearest  
Solahart Dealer to arrange for an inspection.  
EXPANSION CONTROL VALVE RUNNING  
If an expansion control valve is fitted in the cold water line to the water heater (refer to page 29) it may  
discharge a small quantity of water instead of the temperature pressure relief valve on the water heater.  
The benefit is that energy is conserved as the discharged water is cooler.  
PRESSURE RELIEF VALVE DISCHARGING  
A pressure relief valve is incorporated into the gas booster controls. This valve protects the gas  
booster, by allowing water to escape, in the event of excessive pressure build up in the waterways.  
Normal operation  
A small volume of water may discharge from the bottom of the gas booster when a hot tap is  
suddenly closed.  
Continuous dribble  
A continuous dribble may indicate the water supply pressure is above the design pressure for the  
gas booster. If so, a pressure limiting valve must be installed on the cold water supply pipe to the  
water heater (refer to “Mains Water Supply” on page 19).  
FAN CONTINUES TO RUN AFTER WATER HEATER OPERATION STOPS  
It is the normal operation of the gas booster for the fan to continue running after heating of the water is  
finished. The fan may run for up to six minutes after the burners extinguish, to prepare for the next  
ignition.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SAVE A SERVICE CALL  
CLOUDS OF WHITE ‘VAPOUR’ FROM THE FLUE TERMINAL  
During the heating cycle, it is not unusual to see water vapour  
clouds steaming from the flue terminal, particularly on cold days.  
This is normal operation of the gas booster.  
ERROR CODE  
The water heater provides a diagnostic error code in the event of  
an interruption to its operation. The error code is displayed on  
the front of the water heater on the OK MONITOR. If an error  
code appears:  
Close the hot tap and switch off the electrical supply to the  
water heater.  
Wait 5 minutes, then switch on the electrical supply to the  
water heater and open a hot tap.  
If the error code persists, take note of the code and turn off the  
hot tap. Phone your nearest Solahart Dealer to arrange for  
inspection.  
HIGH GAS BILLS  
With the installation of your new solar hot water system, maximum gas energy savings can be achieved  
with careful planning of hot water usage. Should you at any time, feel your gas account is too high, we  
suggest you check the following points:  
Is the relief valve running excessively? (Refer to “Temperature Pressure Relief Valve Running” on  
page 15).  
Is one outlet (especially the shower) using more hot water  
than you think? (Refer to “Gas Booster Operating Too  
Frequently” on page 13).  
Is there a leaking hot water pipe, dripping hot water tap, etc?  
Even a small leak will waste a surprising quantity of hot  
water and energy. Replace faulty tap washers, and have  
your plumber rectify any leaking pipe work.  
Is the gas booster operating too frequently? (Refer to “Gas  
Booster Operating Too Frequently” on page 13).  
Consider recent changes to your hot water usage pattern  
and check if there has been any increase in tariffs since  
your previous account.  
COLLECTOR GLASS  
Warranty DOES NOT cover breakage of solar collector glass. Check your household insurance policy  
covers collector glass breakage.  
Warning: Collector glass must not be replaced whilst the solar collector is on the roof.  
The collector glass is not offered as a replacement part and no attempt should be made to remove it.  
Should the solar collector require replacement, contact your nearest Solahart Dealer.  
IF YOU HAVE CHECKED ALL THE FOREGOING AND STILL BELIEVE YOU NEED ASSISTANCE,  
CALL YOUR NEAREST SOLAHART DEALER.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
INSTALLATION – SOLAR STORAGE TANK  
THIS WATER HEATER IS FOR OUTDOOR INSTALLATION ONLY.  
THIS WATER HEATER IS NOT SUITABLE FOR POOL HEATING.  
Check the water heater is suitable for the gas type available.  
(refer to the rating label on the water heater)  
The system is suitable for installation with Solahart ‘J’ or ‘KF’ solar collectors.  
The solar circuit must be installed with a continuous fall of a minimum 5° in the pipe work from the solar  
collectors to the solar storage tank, the solar hot and solar cold pipes must be fully insulated with closed  
cell polymer insulation (minimum thickness 13 mm) and the system charged with correctly mixed closed  
circuit fluid to offer protection against freeze damage. The system has NO WARRANTY for freeze  
damage if there is not a continuous fall in the solar hot and solar cold pipes or they are uninsulated or  
the closed circuit fluid has been incorrectly mixed (refer to “Warranty Exclusions” on page 53).  
SOLAR WATER HEATER STORAGE TANK LOCATION  
The solar storage tank is suitable for outdoor installation only. The solar storage tank should be  
installed close to the most frequently used outlet and its position chosen with safety and service in  
mind. Make sure people (particularly children) will not touch the flue terminal. The flue terminal and air  
inlet must be clear of obstructions and shrubbery.  
Consideration must also be given to the position of the solar storage tank in relation to the solar  
collectors. There are limitations on both the maximum length of the solar hot and solar cold pipes and  
the maximum height between the solar storage tank and the solar collectors. Refer to “Solar Collector  
Clearance must be allowed for servicing of the solar  
storage tank and gas booster. The solar storage tank  
must be accessible without the use of a ladder or  
scaffold. Make sure the temperature pressure relief  
valve lever is accessible and the front panel and front  
covers can be removed for service.  
You must be able to read the information on the rating  
plate. If possible leave headroom of one water heater  
length so the anode can be inspected or replaced.  
Remember you may have to remove the entire solar  
storage tank later for servicing.  
The installation must comply with these installation  
instructions  
and  
with  
the  
requirements  
of  
AS/NZS 3500.4, AS 5601, AS/NZS 3000 and all local  
codes and regulatory authority requirements. In New  
Zealand, the installation must conform with the New  
Zealand Building Code.  
The water heater must not be installed in an area with a corrosive atmosphere where chemicals are  
stored or where aerosol propellants are released. Remember the air may be safe to breathe, but when  
it goes through a flame, chemical changes take place which may attack the water heater.  
It is recommended the solar storage tank be installed at ground or floor level and must stand vertically  
upright.  
Note: It is important for the solar storage tank to be orientated vertically upright in order for the falling  
film of closed circuit fluid to operate efficiently.  
A secondary flue is not required. The water heater must not be installed indoors or in a confined space.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
INSTALLATION – SOLAR STORAGE TANK  
The top of the solar storage tank must be a minimum of 500 mm below the bottom of the solar  
collectors for the system to operate correctly.  
As a guide the following requirements extracted from the Australian Gas Installations Standard  
AS 5601, must be observed.  
At least 300 mm between the top of the gas booster and the  
eaves.  
At least 300 mm between the gas booster and the edge of  
any opening into the building, measured horizontally along  
the wall.  
At least 300 mm between the gas booster and a return wall  
or external corner, measured horizontally along the wall.  
At least 1500 mm below any openable window.  
At least 1500 mm between the gas booster and any opening  
into a building, in the direction of the flue discharge.  
At least 500 mm between the gas booster and a fence, wall or other obstruction, in the direction of  
the flue discharge.  
The water heater can be turned through 90°, either to the left or to the right, with the discharge from the  
flue terminal discharging parallel to the wall. It is important the distance requirements from the  
Australian Gas Installations Standard AS 5601 are observed.  
FROST PROTECTION  
The water heater has a frost protection system. The frost protection system will protect the water heater  
from damage, by preventing ice forming in the waterways of the water heater, in the event of freezing  
conditions occurring.  
The solar collectors and solar cold and solar hot pipes only contain closed circuit fluid when the pump is  
operating during periods of solar gain when heating is required. When the solar pump stops operating,  
the closed circuit fluid drains back into the storage tank heat exchanger. The closed circuit fluid is an  
anti-freeze agent which, when mixed to the correct specification, can withstand temperatures of -17°C  
before it may freeze.  
The frost protection system to the gas booster will be rendered inoperable if electrical power is not  
available at the water heater. Damage to the water heater caused by freezing of the pipe work to or  
from the water heater is not covered under warranty. Refer to AS/NZS 3500.4 for precautions to be  
taken for installations in frost prone areas. The water heater is not suitable for installation in areas  
where the ambient temperature falls below -20ºC (including wind chill factor).  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION – SOLAR STORAGE TANK  
MAINS WATER SUPPLY  
Where the mains water supply pressure exceeds that shown in the table below, an approved pressure  
limiting valve is required and should be fitted as shown in the installation diagram (refer to diagram on  
Model  
270  
Relief valve setting  
1000 kPa  
850 kPa  
Expansion control valve setting *  
Max. mains supply pressure  
With expansion control valve  
Without expansion control valve  
Min. mains supply pressure  
680 kPa  
800 kPa  
140 kPa  
* Expansion control valve not supplied with the water heater.  
TANK WATER SUPPLY  
If the water heater is supplied with water from a tank supply, then a pressure pump system is  
recommended to ensure a minimum water pressure of 140 kPa is achieved to allow the gas booster to  
operate. Take care to avoid air locks.  
Notes:  
It is not recommended to install this water heater with a low pressure water supply.  
This water heater is not suitable for connection to bore water or spring water unless a water  
treatment device is fitted.  
If sludge or foreign matter is present in the water supply, it is recommended a suitable filter be  
incorporated in the cold water line to the water heater.  
Refer to “Water Supplies” on page 52.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
INSTALLATION – SOLAR STORAGE TANK  
RAIN WATER TANK  
If the solar collectors and solar pipe work are to be installed on a section of roof which is part of a rain  
water runoff collection system, then it is recommended this section of roof and its gutter be isolated  
from the rain water collection system. The gutter should be isolated to a width greater than the solar  
collectors and pipe work and must have suitable drainage. The installer should ensure in the event of a  
leak from the solar collectors or pipe work, a rainwater tank cannot be contaminated with closed circuit  
fluid.  
The section of roof and gutter should be isolated from the rainwater collection system before the  
commissioning of the solar water heater, so that any leak or spillage during commissioning does not  
make its way into the rainwater tank.  
This section of roof and guttering can be isolated by either:  
blocking this section of gutter from the remaining gutter and fitting two separate down pipes, one to  
take any run-off water from that section of roof away to waste and the other to the rainwater  
collection side of the gutter to take the rain water run off to the rain water tank.  
blocking this section of gutter from the remaining gutter and fitting a tube or pipe of a material  
compatible with the gutter material in this section of the gutter and penetrating the separation  
pieces at either end to allow rainwater runoff to pass from one part of the rainwater collection  
system to the other. It may be necessary to fit a down pipe to the section of blocked gutter to take  
any run-off water from that section of roof away to drain.  
installing a false gutter inside of the existing gutter, with a down pipe penetrating the existing gutter  
to take any run-off water from that section of roof away to waste. The false gutter should be no  
deeper than half of the depth of the existing gutter, so as to enable rain water run off to flow under  
the false gutter.  
installing a flashing from the underside of the roofing material, with a continuous fall, to over the  
outside lip of the gutter. The flashing should extend wider than the collectors and pipe work and  
turned up at the ends so if there is leakage of closed circuit fluid, it cannot enter the gutter.  
If any of these solutions are not practical, then the installer should discuss alternative options to suit the  
installation with the house holder.  
Any alterations to the roof drainage system must comply with the relevant building regulations, codes  
and standards.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION – SOLAR STORAGE TANK  
HOT WATER DELIVERY  
This water heater can deliver water at temperatures which can cause scalding. This water heater has  
both a hot water outlet connection and a tempered water outlet connection. The temperature of the  
water from the hot water outlet can be up to 75°C and the water from the tempered water outlet can be  
up to 50°C.  
The delivery water temperature requirements of AS/NZS 3500.4 allow water in excess of 50°C to be  
delivered to fixtures not used primarily for ablution purposes, such as in a kitchen or laundry. These  
types of fixtures can be supplied from the hot water outlet of this water heater.  
It is necessary and we recommend that a tempered water line, from the outlet connection of the  
temperature limiting device, be fitted between the water heater and the hot water outlets in any ablution  
area such as a bathroom or ensuite, to reduce the risk of scalding. The installing plumber may have a  
legal obligation to ensure the installation of this water heater meets the delivery water temperature  
requirements of AS/NZS 3500.4 so that scalding water temperatures are not delivered to a bathroom,  
ensuite or other ablution area.  
The tempered water outlet from this water heater will not deliver temperatures exceeding 50°C, in  
accordance with AS 4032.2 There is no statutory requirement to fit a supplementary temperature  
limiting device if this water heater is installed in other than an early childhood centre, school, nursing  
home or a facility for young, aged, sick or disabled people.  
Where another temperature limiting device is installed adjacent to the water heater, the cold water line  
to the temperature limiting device can be branched off the cold water line either before or after the  
isolation valve, pressure limiting valve and non return valve to the water heater. If an expansion control  
valve is required, it must always be installed after the non return valve and be the last valve prior to the  
water heater. The hot water line to this temperature limiting device must be taken from the hot water  
outlet connection of the water heater and not from the tempered water outlet connection of the water  
heater.  
If a pressure limiting valve is installed on the cold water line to the water heater and the cold water line  
to another temperature limiting device branches off before this valve or from another cold water line in  
the premises, then a pressure limiting valve of an equal pressure setting may be required prior to the  
temperature limiting device.  
Two Temperature Zones  
Using Temperature Limiting Device Integrated with Water Heater  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
INSTALLATION – SOLAR STORAGE TANK  
CIRCULATED HOT WATER FLOW AND RETURN SYSTEM  
A solar water heater should not be installed as part of a circulated hot water flow and return system in a  
building. The benefits of solar gain will be significantly reduced and energy gained from the sun lost  
through the pipe work.  
If a circulated flow and return system is required, it is necessary to bypass the solar water heater and  
install a secondary water heater connected to the hot water flow and return line and supplied from the  
solar water heater. The secondary water heater must be a storage water heater able to provide a hot  
water outlet temperature of at least 60°C. Note: The thermostat must always be set to at least 60°C.  
Temperature Limiting Device  
A temperature limiting device cannot be installed in circulated hot water flow and return pipe work. The  
tempered water supplied from the tempered hot water outlet on this water heater or from another  
temperature limiting device cannot be circulated.  
Where a circulated hot water flow and return system is required in a building, a temperature limiting  
device can only be installed on a dead leg, branching off the circulated hot water flow and return pipe or  
a dead leg installed from the tempered water outlet of this water heater.  
If circulated tempered water were to be returned back to the water heater, depending on the location of  
the return line connection on the water supply line to the water heater, then either:  
water will be supplied to the cold water inlet of the temperature limiting device at a temperature  
exceeding the maximum recommended water supply temperature, or  
when the hot taps are closed no water will be supplied to the cold water inlet of the temperature  
limiting device whilst hot water will continue to be supplied to the hot water inlet of the temperature  
limiting device.  
These conditions may result in either water at a temperature exceeding the requirements of  
AS/NZS 3500.4 being delivered to the hot water outlets in the ablution areas, or the device closing  
completely and not delivering water at all, or the device failing. Under either condition, the operation  
and performance of the device cannot be guaranteed.  
Circulated Hot Water Flow and Return System – Solar Water Heater  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
INSTALLATION – SOLAR STORAGE TANK  
REDUCING HEAT LOSSES  
The cold water line to and the tempered water and hot water lines from the water heater must be  
insulated in accordance with the requirements of AS/NZS 3500.4. The insulation must be weatherproof  
and UV resistant if exposed.  
The pipe work between the solar storage tank and the solar collectors must be insulated in accordance  
with the requirements of AS/NZS 3500.4. The insulation must be weatherproof and UV resistant if  
exposed. The insulation must be fitted up to the connections on both the solar storage tank and the  
solar collectors.  
ANODE TYPES  
The correct anode type for the water supply being used must be fitted in the water heater (refer to  
Total Dissolved Solids in water supply to the water heater  
Anode colour code  
0 – 40 mg/L  
40 – 600 mg/L  
600 – 2500 mg/L  
Green  
Black  
Blue  
SADDLING - PIPE WORK  
To prevent damage to the cylinder when attaching pipe clips or saddles to the water heater jacket, we  
recommend the use of self-drilling screws with a maximum length of 12 mm. Should pre drilling be  
required, extreme caution must be observed when penetrating the jacket of the water heater.  
Note: Damage to the cylinder as a result of saddling to the jacket will void the warranty.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION – SOLAR STORAGE TANK  
DIMENSIONS AND TECHNICAL DATA  
Model  
DBV 270  
Capacity  
Delivery  
270 litres  
Mass  
165 kg (empty)  
435 kg (full)  
Test Point  
Gas Pressure (kPa)  
Hourly Gas  
Min. Gas  
Max. Gas  
Pressure  
(kPa)  
Gas Booster  
Details  
Gas Booster  
Model  
25°C rise Consumption Pressure  
(litres / min)  
(MJ)  
(kPa)  
minimum  
0.17  
maximum  
0.91  
Natural  
271 026 NF  
271 026 PF  
26  
26  
199  
199  
1.13  
2.75  
3.50  
3.50  
Propane  
0.22  
1.20  
Model numbers: N = Natural, P = Propane. Letter N or P is included in the model number, eg DBV 270 N5, to  
denote gas type.  
Specifications are subject to change with ongoing product improvements.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
INSTALLATION – SOLAR STORAGE TANK  
TYPICAL INSTALLATION – OUTDOOR LOCATION  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
INSTALLATION – SOLAR COLLECTORS  
SOLAR COLLECTOR LOCATION  
Consideration must be given to the position of the solar collectors in relation to the solar storage tank.  
There are limitations on both the maximum length of the solar hot and solar cold pipes and the  
maximum height between the solar storage tank and the solar collectors. Refer to “Solar Storage Tank  
The solar collectors must be installed in a shade free position.  
The solar collectors are to be installed facing toward  
the equator (i.e. north facing in the southern  
hemisphere and south facing in the northern  
hemisphere). Where this orientation is not practical, a  
system facing up to 45° from the equator will have its  
efficiency reduced by approximately 5%.  
Inclination of the solar collectors should be  
approximately equal to 90% of the local latitude angle.  
The latitudes of some Australian cities are listed on  
angle for simplicity of installation and appearance, but  
must never be less than 10°. If the roof angle varies  
by 15° from the correct angle, efficiency will be  
reduced by 10%.  
For an installation on a roof with a pitch less than 10°,  
a Variable Pitch stand is required. Refer to your local  
Solar Distributor for details.  
For an installation at right angles to (across) the roof pitch, a Flat Roof stand and an Across Pitch  
stand are both required. Refer to your local Solar Distributor for details.  
For an installation opposite to (against) the roof pitch, a Flat Roof stand and an Against Pitch stand  
are both required. Refer to your local Solar Distributor for details.  
The collector kit is suitable for installations with an inclination of up to 45°. Where the solar  
collectors are installed at inclinations greater than 45°, a With Pitch frame is necessary. Refer to  
your local Solar Distributor for details.  
The roof must be suitable to take the mass of the solar collectors. Each solar collector and its  
fittings weighs approximately 45 kg when full of water.  
The installation must comply with the requirements of AS/NZS 3500.4 and all local codes and  
regulatory authority requirements.  
Refer to the installation instructions supplied with the collector kit for details on the installation of  
the solar collectors.  
LATITUDE OF SOME AUSTRALIAN CITIES  
Adelaide  
Cairns  
Hobart  
Port Hedland  
Rockhampton  
Sydney  
35°S  
24°S  
27°S  
31°S  
17°S  
35°S  
12°S  
28°S  
42°S  
34°S  
38°S  
32°S  
20°S  
24°S  
34°S  
19°S  
Alice Springs  
Brisbane  
Canberra  
Darwin  
Mildura  
Melbourne  
Perth  
Broken Hill  
Geraldton  
Townsville  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
INSTALLATION – SOLAR COLLECTORS  
PIPE LENGTHS  
The solar hot and solar cold pipes between the solar storage tank and the solar collectors shall:  
be of DN15 hard drawn copper pipe.  
have a continuous fall from the solar collectors to the solar storage tank of a minimum 5° (1 in  
10 grade).  
not exceed the maximum recommended lengths as specified in the table.  
Maximum recommended total combined pipe length and number of 90° bends  
1 or 2 Collectors  
3 Collectors  
Pipe Size  
Pipe Length  
40 metres  
Pipe Length  
30 metres  
90° Bends  
90° Bends  
DN15  
20  
20  
For each additional 90° bend, reduce the maximum total pipe length by 0.5 metres.  
For each additional metre of pipe length, reduce the number of 90° bends by two.  
Note: One 90° elbow is equal to two 90° bends.  
Notes:  
It is important not to cross connect the solar cold and solar hot pipes to the incorrect connections.  
The solar cold pipe connects to the bottom of the solar collectors and the solar hot pipe connects to  
the top of the solar collectors diagonally opposite to the solar cold pipe connection.  
The hot sensor connection is at the top of the solar collector, directly above the solar cold inlet  
connection.  
Refer to “Warning: Plumber – Be Aware” on page 28.  
It is essential for these requirements to be followed for the system to operate correctly and efficiently.  
Solar pipe work which is oversized, or does not have the correct fall, or is too long can result in the  
drain back system not operating effectively.  
Maximum Height To Collectors  
The solar collectors must be the highest point of the system. The maximum height of the solar  
installation, from the base of the solar storage tank to the top of the solar collectors, is 9 m. The pump  
will not circulate closed circuit fluid through heights greater than 9 m and solar gain will not be achieved.  
For heights greater than 9 m, an auxiliary pump must be installed. Refer to “Auxiliary Pump” on  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
INSTALLATION – SOLAR COLLECTORS  
WARNING: Plumber – Be Aware  
The solar hot and solar cold pipes between the solar storage tank and the solar collectors  
MUST BE of copper and fully insulated with closed cell polymer insulation or similar (minimum  
thickness 13 mm). The insulation must be weatherproof and UV resistant if exposed. All  
compression fittings must use brass or copper olives.  
The insulation will offer corrosion protection to a metal roof against water runoff over the copper  
pipe, assist in avoiding accidental contact with the solar pipe work and also reduce pipe heat  
losses.  
The insulation must be fitted up to the connections on both the solar collectors and the  
solar storage tank, as very high temperature closed circuit fluid can flow from the solar  
collectors to the solar storage tank under certain conditions.  
Plastic pipe MUST NOT be used, as it will not withstand the temperature of the closed circuit  
fluid generated by the solar collectors under stagnation conditions. The solar collectors can  
generate extremely high closed circuit fluid temperatures up to 150°C. Plastic pipe cannot  
withstand these temperatures and MUST NOT be used. Failure of plastic pipe can lead to the  
release of high temperature closed circuit fluid and cause severe water damage and flooding.  
There must be a continuous fall in the pipe work between the solar collectors and solar  
storage tank for efficient and effective drain back to occur. The highest point of the solar cold  
pipe and solar hot pipe must be where they connect to the solar collectors.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CONNECTIONS – PLUMBING  
CONNECTION SIZES  
Hot water connection: RP¾/20.  
Cold water connection: RP¾/20.  
Tempered water connection: RP¾/20  
Solar hot (from collector) connection: DN15 compression fitting.  
Solar cold (to collector) connection: DN15 compression fitting.  
Temperature Pressure Relief valve connection: RP½/15.  
Gas connection: R¾/20.  
All plumbing work must be carried out by a qualified person and in accordance with the National  
Plumbing Standard AS/NZS 3500.4 and local authority requirements.  
All gas work must be carried out by a qualified person and in accordance with the Australian Gas  
Installations Standard AS 5601 and local authority requirements.  
It is necessary to remove the pipe cover from underneath the gas booster, by undoing the retaining  
screws, in order to make the water and gas connections to the water heater. Refit the pipe cover at the  
completion of the installation.  
WATER INLET AND OUTLETS  
All pipe work must be cleared of foreign matter before  
connection and purged before attempting to operate the  
water heater. All olive compression fittings must use  
brass or copper olives. Use thread sealing tape or  
approved thread sealant on all fittings.  
An isolation valve and non return valve must be  
installed on the cold water line to the water heater. Use  
the arrangement shown in the diagram. Refer also to  
“Hot Water Delivery” on page 21. The plumbing  
arrangements for the cold water inlet, tempered water  
and hot water outlets are shown on page 29. The solar  
hot and solar cold pipe connections are shown on  
A disconnection union must always be provided at the  
cold water inlet, tempered water and hot water outlets  
on the water heater to allow for disconnection of the  
water heater. It is necessary to remove the brass plug  
from the hot water outlet fitting if a hot water line is to  
be installed. This plug can be used to plug the  
hot water  
outlet  
tempered water outlet if a tempered water line is not  
being installed. Refer to the diagram for the connection  
points to the water heater.  
tempered  
water outlet  
cold water  
Insulation used on the tempered water and hot water  
lines must extend up to the outlets of the water heater.  
The valve and fittings must also be insulated up to the  
hot water outlet of the gas booster.  
inlet  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
CONNECTIONS – PLUMBING  
This solar storage tank has either a plastic dip tube or  
fitting liner in the inlet and outlet fittings (see diagram).  
These must be in place for the water heater to function  
properly. Do not remove or damage them by using heat  
nearby. They will be pushed into the correct position as  
the fitting is screwed in.  
PIPE SIZES  
To achieve true mains pressure operation, the cold water line to the water heater should be the same  
size or bigger than the tempered water and hot water lines from the water heater. The minimum  
recommended tempered pipe and hot pipe sizes are DN20.  
The pipe sizing for hot water supply systems should be carried out by persons competent to do so,  
choosing the most suitable pipe size for each individual application. Reference to the technical  
specifications of the water heater and local regulatory authority requirements must be made.  
RELIEF VALVE  
The temperature pressure relief valve is shipped behind the lower front cover of the water heater. The  
temperature pressure relief valve must be fitted before the water heater is operated. Before fitting the  
relief valve, make sure the probe has not been bent. Seal the thread with Teflon tape - never hemp.  
Make sure the tape does not hang over the end of the thread.  
Screw the valve into the correct opening (refer to the installation diagram on page 25) leaving the valve  
outlet pointing downwards. Do not use a wrench on the valve body - use the spanner flats provided.  
RELIEF VALVE DRAIN  
Temperature Pressure Relief Valve  
A copper drain line must be fitted to the relief valve to carry the discharge clear of the water heater.  
Connect the drain line to the relief valve using a disconnection union. The pipe work from the relief  
valve to the drain should be as short as possible and fall all the way from the water heater with no  
restrictions. It should have no more than three right angle bends in it. Use DN15 pipe.  
The outlet of the drain line must be in such a position that flow out of the pipe can be easily seen (refer  
to AS/NZS 3500.4) - but arranged so hot water discharge will not cause injury, damage or nuisance.  
The drain line must discharge at an outlet or air break not more than 9 metres from the relief valve.  
In locations where water pipes are prone to freezing, the drain line must be insulated and not exceed  
300 mm in length. In this instance, the drain line is to discharge into a tundish through an air gap of  
between 75 mm and 150 mm.  
Warning: As the function of the temperature pressure relief valve on this water heater is to  
discharge high temperature water under certain conditions, it is strongly recommended the pipe work  
downstream of the relief valve be capable of carrying water exceeding 93°C. Failure to observe this  
precaution may result in damage to pipe work and property.  
Solar Circuit Relief Valve  
Ensure the outlet of the solar circuit relief valve is facing toward the rear of the water heater installation.  
A copper drain line must be fitted to the relief valve to carry the discharge clear of the water heater.  
Connect the drain line to the relief valve using a disconnection union. The pipe work from the relief  
valve to the drain should be as short as possible and fall all the way from the water heater with no  
restrictions. It should have no more than three right angle bends in it. Use DN10 pipe.  
The outlet of the drain line must be in such a position that flow out of the pipe can be easily seen (refer  
to AS/NZS 3500.4) - but arranged so hot water discharge will not cause injury, damage or nuisance.  
The drain line must discharge at an outlet or air break not more than 9 metres from the relief valve.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONNECTIONS – PLUMBING  
In locations where water pipes are prone to freezing, the drain line must be insulated and not exceed  
300 mm in length. In this instance, the drain line is to discharge into a tundish through an air gap of  
between 75 mm and 150 mm.  
EXPANSION CONTROL VALVE  
Local regulations may make it mandatory to install an expansion control valve (ECV) in the cold water  
line to the water heater. In other areas, an ECV is not required unless the saturation index is greater  
than +0.4 (refer to “Water Supplies” on page 52). However, an ECV may be needed in a corrosive  
water area where there are sufficient quantities of silica dissolved in the water.  
The expansion control valve must always be installed after the non return valve and be the last valve  
installed prior to the water heater (refer to diagram on page 29). A copper drain line must be run  
separately from the drain of the relief valve.  
GAS INLET  
The gas connection is made at the underside of the gas  
booster. The pipe work must be cleared of foreign  
matter before connection and purged before attempting  
to operate the water heater. An isolation valve and  
disconnection union must be installed to allow servicing  
on page 31). Refer to the Gas Installations Standard  
AS 5601 for the correct pipe sizing.  
Note: The pipe size selection must take into account  
the high gas input of the gas booster (refer to table on  
page 24) as well as all of the other gas appliances in  
the premises.  
Warning: Always isolate the gas booster before  
pressure testing the gas supply system. Disconnect the  
gas booster after the isolating cock to prevent the risk  
of serious damage to the gas control. Warranty does  
gas inlet  
not cover damage of any nature resulting from failure to  
observe this precaution. Refer to rating label for gas  
types and pressures.  
SOLAR INLET AND OUTLET  
All pipe work must be cleared of foreign matter before connection and purged before attempting to  
operate the water heater. All olive compression fittings must use brass or copper olives. Use thread  
sealing tape or approved thread sealant on all fittings.  
The solar cold outlet and solar hot inlet connections are located at the top of the solar storage tank.  
Notes:  
It is important not to cross connect the solar cold and solar hot pipes to the incorrect connections.  
ƒ
The solar cold pipe connects to the bottom of the solar collectors and the solar hot pipe  
connects to the top of the solar collectors on the opposite side to both the solar cold pipe  
connection and the hot sensor connection.  
ƒ
ƒ
The solar hot inlet connection is located in the centre of the top of the solar storage tank (the  
connection is marked by a label on top of the storage tank).  
The solar cold outlet connection is located toward the outer edge of the top of the solar storage  
tank (the connection is marked by a label on top of the storage tank).  
Connect the solar pipes to the solar storage tank using only the fittings supplied.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CONNECTIONS – PLUMBING  
To connect the solar cold and solar hot pipes to the solar storage tank:  
Remove the compression nut and olive from each  
of the solar cold outlet and solar hot inlet fittings at  
the top of the solar storage tank. Remove the  
rubber washer from each of the unions and  
discard.  
compression nut & olive  
Connect the solar cold pipe (flow to the collector) to  
the nipple in the solar cold outlet using the  
compression nut and olive supplied.  
solar hot pipe  
connection  
solar cold pipe  
connection  
Connect the solar hot pipe (flow from the collector)  
to the nipple in the solar hot inlet using the  
compression nut and olive supplied.  
AUXILIARY PUMP  
The maximum height of the solar installation from the base of the solar storage tank to the top of the  
solar collectors is 9 m. The pump supplied with the solar storage tank will not circulate closed circuit  
fluid through heights greater than 9 m and solar gain will not be achieved. For heights greater than 9 m,  
an auxiliary pump must be installed. This pump is the same model as contained within the solar storage  
tank.  
The auxiliary pump (kit PN 299914) is to be installed:  
on the solar cold pipe from the solar storage tank to the solar collectors  
within 1 m of the top of the solar storage tank  
with the inlet and outlet in a vertical orientation  
securely fixed to a structure, such as a wall, with suitable screws or anchors.  
wired to the control board (refer to “Auxiliary Pump” on page 34).  
within a suitable weatherproof enclosure to protect it from rain as the pump is not weatherproof.  
The installation of an auxiliary pump will enable a maximum height of 18 m to be achieved.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CONNECTIONS – ELECTRICAL  
The power supply to the water heater must not be switched on until the water heater is filled  
with water.  
MEGGER READING  
It is not mandatory to conduct a megger test on a plug in appliance, however if a megger test is  
conducted on this water heater, then the following should be noted.  
Warning: This water heater contains electronic equipment and 500 V insulation tests must only be  
conducted between either active and earth or neutral and earth. An active to neutral test WILL damage  
the electronics.  
An insulation test result of approximately 660 Kfor this water heater is normal.  
Typically the insulation resistance between live and earthed parts of an electrical installation should not  
be less than 1 M. However AS/NZS 3000:2000 clause 6.3.3.3.2 ‘Results’ states:  
“The value of 1 Mmay be reduced to:  
0.01 Mfor sheathed heating elements or appliances; or  
a value permitted in the Standard applicable to electrical equipment.”  
This model water heater is categorised as a ‘stationary class 1 motor operated appliance’ and has been  
tested to AS/NZS 3350.1:2002 clause 16 ‘Leakage current and electric strength’ and has passed the  
requirements of this Standard. Therefore, this model water heater complies with the condition stated in  
AS/NZS 3000:2000 clause 6.3.3.3.2 (b).  
ELECTRICAL CONNECTION  
All electrical work and permanent wiring must be carried out by a qualified person and in accordance  
with the Wiring Rules AS/NZS 3000 and local authority requirements.  
Warning: Temperature controllers must not be fitted to this water heater as part of a solar water  
heater system because water at a temperature much higher than the controller setting can be delivered.  
The water heater requires a 240 V AC, 50 Hz mains power supply for operation. The solar storage tank,  
supplied with a 1.8 metre power cord to operate the solar control unit and gas booster, requires a  
switched general purpose outlet (GPO) to be located within 1.2 metres of the installation. The GPO  
must have a continuous power supply. The GPO is required to be weatherproof if installed outdoors.  
The power consumption of the water heater is:  
Power  
consumption  
Component  
Solar controller  
Solar pump  
Comments  
3 Watts  
Constant load  
Maximum load at solar heating cycle start up  
(for approximately two (2) minutes)  
165 Watts  
50 Watts  
Average load during the solar heating cycle  
Anti frost device active  
Gas booster  
150 Watts  
The water heater will only operate on a sine wave at 50 Hz. Devices generating a square wave cannot  
be used to supply power to the water heater.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CONNECTIONS – ELECTRICAL  
HOT SENSOR LEAD  
House the hot sensor lead at the water heater in the flexible conduit provided and secure the conduit in  
the cut out on the tab located behind the upper front cover. Connect the hot sensor cable to the hot  
sensor cable connector located on the tab behind the upper front cover. Secure the hot sensor lead to  
the water heater jacket to prevent possible damage.  
TEMPERATURE SETTING  
The preset outlet booster temperature setting of the gas booster should not be adjusted. The setting  
can only be adjusted by your nearest Solahart Dealer. The preset outlet booster temperature setting is  
60°C.  
AUXILIARY PUMP  
The auxiliary pump, if installed, must be wired to the control board. The wiring must be housed in a  
flexible conduit, which must be secured to the side of the solar storage tank. Connect the wiring to the  
terminals on the auxiliary pump and to the terminals marked “2nd Pump” on the control board. Refer to  
WIRING DIAGRAM  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
COMMISSIONING  
TO FILL AND TURN ON THE WATER HEATER  
The power supply to the solar storage tank and solar control unit must not be switched on until  
the water heater is filled with water.  
Open all of the hot water taps in the house (don’t forget the shower).  
Open the cold water isolation valve fully on the cold water line to the water heater.  
Air will be forced out of the taps.  
Close each tap as water flows freely from it.  
Check the pipe work for leaks.  
Open the gas isolation valve fully.  
Check the gas pipe work for leaks.  
Open the isolation valve in the pipe work between the outlet of the heat exchanger and the solar  
pump, located behind the lower front cover of the solar storage tank.  
Plug in the water heater at the power outlet.  
Commission the solar circuit (refer to “Solar Circuit” on page 36).  
Switch on the electrical supply at the power outlet to the water heater.  
The power outlet must be switched on for the solar controls to operate and solar gain to be  
achieved and for the gas booster to operate and have its frost protection activated.  
Check the gas inlet and burner gas pressure of the gas booster (refer to “Gas Inlet Pressure” on  
page 48 and “Burner Gas Pressure” on page 48).  
Open a hot tap.  
The gas booster will operate automatically.  
Check to ensure the flow from each connected hot tap is sufficient to operate the gas booster.  
The minimum operating flow rate for all models is 3.0 litres per minute.  
Explain to the householder the functions and operation of the solar water heater.  
Warning: Upon completion of the installation and commissioning of the water heater, leave this  
guide with the householder or responsible officer. DO NOT leave this guide inside of the cover of the  
water heater, as it may interfere with the safe operation of the water heater or ignite when the water  
heater is turned on.  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
COMMISSIONING  
SOLAR CIRCUIT  
It is necessary to commission and check the operation of the solar circuit. The commissioning  
procedure includes:  
checking the circulation of closed circuit fluid through the solar circuit.  
checking the drain back function of the solar circuit.  
pressure testing the solar circuit to ensure there are no leaks.  
checking the level of the closed circuit fluid and adjusting if required.  
The water heater is supplied charged with closed circuit fluid. The level of the closed circuit fluid only  
needs to be checked if:  
a third solar collector is installed.  
there is a significant leak in the solar pipe work and closed circuit fluid has been discharged.  
the maximum recommended solar pipe length is exceeded.  
a second solar pump is installed if the maximum height from the base of the solar storage tank to  
the top of the solar collectors exceeds 9 m (refer to “Pipe Lengths” on page 27).  
Additional Equipment  
Additional equipment will be required for the commissioning and checking of the solar circuit. This  
includes checking the closed circuit fluid level and conducting a drain back test. The following  
equipment is required:  
a 1500 mm long x 12 mm (½”) diameter clear hose (closed circuit fluid level hose).  
one (1) ½” hose clamp.  
a suitable plug for one end of the hose.  
suitable tape to affix the hose to the side of the solar storage tank.  
a torch to illuminate the working area under the heat exchanger and storage tank cylinder.  
Closed Circuit Fluid  
The water heater is supplied charged with closed circuit fluid and it is not necessary to add further  
closed circuit fluid to the system. If the closed circuit fluid has been completely drained or discharged  
from the solar circuit and needs to be replaced, then the amount to be added is:  
5 litres of Hartgard concentrate, mixed with  
11 litres of water.  
It is necessary to undertake the solar circuit commissioning procedure if the closed circuit fluid has  
been replaced.  
The closed circuit fluid contains food grade additives (rust inhibitor, anti-freeze agent, colour) and is  
harmless to the environment. However, it is good practice to recover any excess closed circuit fluid and  
remove from site.  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
COMMISSIONING  
Warning: Although non-toxic, the following first aid advice and procedures should be followed if the  
closed circuit fluid concentrate comes into human contact or is spilt:  
Swallowed - give milk or water and seek medical attention.  
Eyes - wash with running water.  
Skin - remove contaminated clothing and wash skin with water and soap.  
Inhaled - seek fresh air, rest and keep warm.  
Spilt - immediately remove contaminated clothing, stop leak source, absorb with a dry agent and  
eliminate any ignition sources nearby.  
PRE-COMMISSIONING WARNINGS  
It is recommended to conduct the solar circuit commissioning procedure with the solar collectors  
covered, otherwise during the commissioning and checking procedure of the solar circuit, the  
closed circuit fluid may experience solar gain as it passes through the solar collectors. This will  
increase both the temperature and pressure of the closed circuit fluid and air inside of the solar  
circuit.  
The electrical supply must be switched off before the solar circuit is opened either at the solar  
circuit relief valve or at the compression nut on either of the solar hot or solar cold pipes at the top  
of the solar storage tank.  
If it is necessary to open the solar circuit at the solar circuit relief valve or at the compression nut on  
either of the solar hot or solar cold pipes at the top of the solar storage tank, then care must be  
taken so as not to be scalded by either the closed circuit fluid or the air escaping from the solar  
circuit.  
Pre-Commissioning Notes  
Before commencing the solar circuit commissioning procedure, check the solar cold and solar hot  
pipe work to ensure:  
ƒ
there is a continuous fall from the solar collectors to the solar storage tank of a minimum 5°  
(1 in 10 grade).  
ƒ
ƒ
the maximum recommended pipe length is not exceeded.  
the maximum height from the base of the solar storage tank to the solar collector is not  
exceeded.  
Rectify the solar pipe work if there is either insufficient fall or not a continuous fall of at least 5°  
from the solar collectors to the solar storage tank or if either of the maximum pipe length or  
maximum height of the system has been exceeded, before commencing the solar circuit  
commissioning procedure. Refer to “Pipe Lengths” on page 27.  
The solar collectors will gain a high level of heat during periods of solar radiation. If the solar pump  
is activated during a period of high solar radiation and the solar collectors have not been covered,  
the initial flow of closed circuit fluid will absorb this heat and a rumbling sound may be heard. This  
is normal and the solar circuit will achieve a stable operating condition once full flow through the  
solar circuit is established.  
The solar pump is set on the speed setting 3. This speed setting must not be adjusted. The solar  
control unit automatically controls and adjusts the speed of the pump to maximise solar  
contribution. Manual adjustment of the speed dial setting may result in the system not operating  
correctly or efficiently.  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COMMISSIONING  
Commissioning the Solar Circuit  
To commission and check the solar circuit:  
1. Switch off the electrical supply at the power outlet to  
the solar storage tank.  
heat exchanger  
isolation valve open  
If the pump has been operating, wait five minutes to  
allow the drain back of the closed circuit fluid in the  
solar circuit.  
2. Remove the pipe cover from below the gas booster  
and the lower and upper front covers from the solar  
storage tank.  
3. Ensure the isolation valve in the pipe work between  
the outlet of the heat exchanger and the solar pump,  
located behind the lower front cover of the solar  
storage tank, is fully open.  
Attach Closed Circuit Fluid Level Hose  
4. Attach the clear hose to the solar circuit.  
To attach the hose:  
heat  
exchanger  
drain valve  
closed  
ƒ
Ensure the heat exchanger drain valve is closed.  
attach  
hose  
The heat exchanger drain valve is located  
adjacent to the solar pump, behind the lower front  
cover of the solar storage tank.  
ƒ
Attach one end of the hose to the hose tail  
connection.  
It may be necessary to secure the hose with a  
hose clamp.  
ƒ
ƒ
Plug the free end of the hose.  
Affix the hose securely in a vertical orientation to  
the front of the solar storage tank using tape,  
adjacent to the text, “MINIMUM FLUID LEVEL  
WITH PUMP OPERATING”.  
affix hose  
to tank  
5. Disconnect the drain line from the solar circuit relief  
valve at the top of the solar storage tank. Remove the  
spring clip from the solar circuit relief valve and  
remove the valve.  
Warning: The solar circuit may be under  
pressure. Take care when removing the solar circuit  
relief valve, as a sudden discharge of pressurised hot  
air may be experienced. This discharge will create a  
sharp sound of air being released.  
disconnect  
drain line  
and remove  
solar circuit  
relief valve  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
COMMISSIONING  
6. Open the heat exchanger drain valve and remove the  
heat  
plug from the end of the hose.  
exchanger  
drain valve  
open  
The closed circuit fluid will flood the hose to the static  
level of the closed circuit fluid inside of the heat  
exchanger.  
7. Mark the static level of the closed circuit fluid on the  
side of the solar storage tank with a non permanent  
marker.  
Solar Circuit Circulation  
8. Disconnect the hot sensor lead from the connecting  
plug located on the tab in the upper front cover  
opening.  
It is important, at the end of this procedure when the  
commissioning and checking of the solar circuit is  
complete, to reconnect the hot sensor lead, otherwise  
when the electrical supply is switched on, the solar  
pump will deactivate after one hour and the solar  
control unit will then enter a fault mode and no solar  
gain will be achieved.  
disconnect hot  
sensor lead  
9. Switch on the electrical supply at the power outlet to the solar storage tank.  
Warning: Take care not to enter the area inside the solar storage tank behind the front cover  
whilst the power is on as the electrical circuit will be live.  
The pump will activate and commence pumping closed circuit fluid around the solar circuit.  
The level of the closed circuit fluid in the clear hose will slowly drop to the dynamic operating level.  
Allow the pump to operate for three (3) minutes (one and two collector systems) or for five (5)  
minutes (3 collector system) to allow the solar circuit to fill with closed circuit fluid and stabilise.  
Note: The solar pump will operate for one hour with the hot sensor lead disconnected, before  
automatically turning itself off (refer to step 12).  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
COMMISSIONING  
10. Check the closed circuit fluid is circulating around the solar circuit.  
To check circulation:  
ƒ
Listen for the trickling sound of the closed circuit fluid returning into the heat exchanger by  
placing your ear against the side toward the top of the solar storage tank.  
If the fluid is circulating around the solar circuit, a trickling sound will be heard as the fluid  
returns back into the heat exchanger.  
If no trickling sound is heard, check:  
¾
¾
the hot sensor lead is disconnected at the solar storage tank.  
If connected, disconnect the hot sensor lead at the solar storage tank (refer to step 8).  
the isolation valve in the pipe work between the outlet of the heat exchanger and the solar  
pump, located behind the lower front cover of the solar storage tank, is fully open.  
Warning: Switch off the electrical supply at the power outlet to the solar storage tank  
before entering the area inside the solar storage tank behind the front cover.  
If closed, open the isolation valve on the outlet of the heat exchanger (refer to step 3).  
¾
there is no leakage from the solar circuit. It is important to check all of the solar circuit pipe  
work, including in the roof space and on the roof.  
If leaking, rectify any leaks in the solar circuit.  
¾
¾
the height from the base of the storage tank to the top of the collectors has not exceeded  
the maximum allowable height.  
the length of solar cold and solar hot pipe has not exceeded the maximum recommended  
pipe length.  
If the maximum allowable height or the maximum recommended pipe length has been  
exceeded, it may be necessary to relocate the solar collectors to either a lower level or  
closer to the solar storage tank, or install a second solar pump, or relocate the solar  
storage tank closer to the solar collectors. Refer to “Pipe Lengths” on page 27.  
11. Mark the dynamic level of the closed circuit fluid in the  
hose on the side of the solar storage tank with a non  
permanent marker when satisfied the solar circuit  
circulation is operating satisfactorily.  
mark dynamic  
level on tank  
12. If the procedure to check the solar circuit circulation is  
not complete before the pump has automatically  
turned off, then:  
ƒ
ƒ
switch off the electrical supply at the power outlet to the solar storage tank.  
wait ten (10) minutes for the operating system to reset to its commissioning sequence,  
otherwise the pump will not operate when the power supply is switched on.  
ƒ
recommence this procedure from step 9.  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
COMMISSIONING  
Drain Back Function  
13. Switch off the electrical supply at the power outlet to the solar storage tank.  
The pump will deactivate.  
The closed circuit fluid will drain back down to the heat exchanger and the level of the closed circuit  
fluid in the clear hose will rise.  
Wait five (5) minutes to allow the drain back of the closed circuit fluid in the solar circuit.  
14. Note the level of the closed circuit fluid in the fluid level hose.  
The closed circuit fluid should drain back to the original static level.  
If the closed circuit fluid does not drain back completely to this level, then check:  
ƒ
there is a continuous fall of at least 5° (1 in 10 grade) in the solar pipe work from the solar  
collectors to the solar storage tank.  
ƒ
the solar collectors have an inclination of not less than 10°.  
(refer to “Solar Collector Location” on page 26)  
ƒ
the connectors on the inlet and outlet of the collectors are orientated downwards to ensure  
complete drain back of the closed circuit fluid from the solar collectors.  
If necessary, rectify the:  
ƒ
ƒ
ƒ
solar pipe work if there is either insufficient fall or not a continuous fall in the pipe work.  
solar collector inclination if it is less than 10°.  
orientation of the connectors downwards if they are not orientated correctly.  
Recheck the drain back function of the solar circuit by repeating step 7 and recommencing this  
procedure from step 9.  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COMMISSIONING  
Closed Circuit Fluid Level  
15. Measure the distance from the text marking “MINIMUM FLUID LEVEL WITH PUMP OPERATING”  
to the closed circuit fluid dynamic level marked on the side of the solar storage tank during step 11.  
The correct closed circuit fluid dynamic level for efficient operation of the system when the pump is  
operating is between the “MINIMUM FLUID LEVEL WITH PUMP OPERATING” text marking on the  
side of the solar storage tank and 150 mm above this mark.  
ƒ
If the closed circuit fluid dynamic level marked on the side of the solar storage tank during  
step 11 is greater than 150 mm above the text marking, it will be necessary to drain closed  
circuit fluid from the heat exchanger.  
ƒ
If the closed circuit fluid dynamic level is below the text marking, it will be necessary to add  
water to the heat exchanger to top up the level of closed circuit fluid.  
There is sufficient Hartgard concentrate in the solar circuit heat exchanger such that only water  
needs to be added to the system if it is required to top up the level of closed circuit fluid.  
Note: The operating dynamic level of the closed circuit fluid, upon the completion of  
commissioning, must not be less than the “MINIMUM FLUID LEVEL WITH PUMP OPERATING”  
text marking on the side of the solar storage tank or greater than 150 mm above this mark.  
If the dynamic fluid level is greater  
than 150 mm above the text marking, it  
will be necessary to drain closed circuit  
fluid from the heat exchanger  
Y mm’  
greater  
than  
150 mm  
above text  
marking  
MINIMUM FLUID LEVEL WITH PUMP OPERATING  
X mm’  
below text  
marking  
If the dynamic fluid level is below  
the text marking, it will be necessary  
to add water to the heat exchanger  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COMMISSIONING  
16. Determine the correct amount of water to be added to or closed circuit fluid to be drained from the  
heat exchanger if the dynamic level is either below the text marking “MINIMUM FLUID LEVEL  
WITH PUMP OPERATING” or more than 150 mm above this mark.  
Each 100 mm of fluid level height is equivalent to three (3) litres of closed circuit fluid.  
20 mm  
40 mm  
60 mm  
0.6 litres  
1.2 litres  
1.8 litres  
80 mm  
100 mm  
120 mm  
2.4 litres  
3.0 litres  
3.6 litres  
140 mm  
160 mm  
180 mm  
4.2 litres  
4.8 litres  
5.4 litres  
ƒ
Mark the required closed circuit fluid level to be obtained on the side of the solar storage tank  
with a non permanent marker beside the clear hose, in relation to the static level marked on the  
side of the solar storage tank during step 7.  
Eg: If the dynamic level is 30 mm below the text marking, then place a mark 30 mm above the  
static level marked on the side of the solar storage tank in step 7. It would be necessary to add  
one litre of water to the heat exchanger.  
Eg: If the dynamic level is 180 mm above the text marking, then place a mark at least 30 mm,  
but no more than 180 mm, below the static level marked on the side of the solar storage tank.  
It would be necessary to drain between one litre and five litres of closed circuit fluid from the  
heat exchanger.  
mark  
X mm’  
mark static level to achieve  
above  
static mark  
mark between  
Y mm’ and  
‘Y + 150 mm’  
below static  
mark  
static level marked on tank during step 7  
mark static level to achieve  
If the dynamic fluid level is greater than  
150 mm above the text marking, then  
place a mark below the static level marked  
on the tank of between equal to this  
distance and this distance plus 150 mm.  
Y mm’  
greater  
than  
150 mm  
above text  
marking  
MINIMUM FLUID LEVEL WITH PUMP OPERATING  
X mm’  
below text  
marking  
If the dynamic fluid level is below the text  
marking, then place a mark equal to this distance  
above the static level marked on the tank  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COMMISSIONING  
17. Add water to top up the level of the closed circuit fluid in the heat exchanger if required.  
To add water to the closed circuit fluid:  
ƒ
If not already removed, disconnect the drain line and remove the spring clip from the solar  
circuit relief valve at the top of the solar storage tank and remove the valve (refer to step 5).  
Warning: The solar circuit may be under pressure. Take care when removing the solar  
circuit relief valve, as a sudden discharge of pressurised hot air may be experienced. This  
discharge will create a sharp sound of air being released.  
ƒ
ƒ
Place a funnel in the relief valve fitting.  
Add water slowly through the funnel until the level of fluid in the hose is at the desired level as  
marked on the solar storage tank.  
Note: It may be necessary to undo the compression nut on the solar hot pipe at the top of the  
solar storage tank and loosen the pipe work from the fitting to assist the flow of water into the  
closed circuit through the funnel.  
ƒ
ƒ
Remove the funnel from the relief valve fitting.  
Position the solar hot pipe correctly in its fitting and tighten the compression nut if this has been  
loosened.  
18. Drain closed circuit fluid from the heat exchanger if required.  
To drain closed circuit fluid:  
ƒ
If not already removed, disconnect the drain line and remove the spring clip from the solar  
circuit relief valve at the top of the solar storage tank and remove the valve (refer to step 5).  
Warning: The solar circuit may be under pressure. Take care when removing the solar  
circuit relief valve, as a sudden discharge of pressurised hot air may be experienced. This  
discharge will create a sharp sound of air being released.  
ƒ
Place the end of the solar fluid hose into a graduated volumetric container and drain closed  
circuit fluid until the level of fluid in the hose is at the desired level as marked on the solar  
storage tank.  
It may be necessary to drain off the closed circuit fluid in small amounts, raising the hose back  
to the top of the solar storage tank and noting the level of the closed circuit fluid in the clear  
hose each time, so as not to drain below the desired level.  
Note: The closed circuit fluid contains food grade additives (rust inhibitor, anti-freeze agent,  
colour) and is harmless to the environment. However, it is good practice to recover any excess  
fluid and remove from site.  
ƒ
Re-affix the hose to the same location on the side of the solar storage tank.  
19. If water has been added to or closed circuit fluid has been drained from the heat exchanger,  
recommence this procedure from step 9.  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COMMISSIONING  
Pressure Testing the Solar Circuit  
20. Close the heat exchanger drain valve.  
heat  
exchanger  
drain valve  
closed  
21. Refit the solar circuit relief valve, orientating the valve  
outlet to the rear of the solar storage tank. Secure  
with the spring clip. Reconnect the drain pipe to the  
valve.  
22. Switch on the electrical supply at the power outlet to  
the solar storage tank.  
The pump will activate and commence pumping fluid around the solar circuit.  
Note: The level of the closed circuit fluid in the clear hose will not change, as the heat exchanger  
drain valve has been closed.  
Allow the pump to operate for three (3) minutes (one and two collector systems) or for five (5)  
minutes (3 collector system) to allow the solar circuit to stabilise and fill with closed circuit fluid.  
Note: The solar pump will operate for one hour with the hot sensor lead disconnected, before  
automatically turning itself off. Refer to step 24.  
23. Check the solar pipe work and collector unions for leaks whilst the pump is operating and the solar  
circuit is at its working pressure. It is important to check all of the solar circuit pipe work, including in  
the roof space and on the roof.  
24. If the procedure to check the solar pipe work for leaks is not complete before the pump has  
automatically turned off, then:  
ƒ
ƒ
switch off the electrical supply at the power outlet to the solar storage tank.  
wait ten (10) minutes for the operating system to reset to its commissioning sequence,  
otherwise the pump will not operate when the power supply is switched on.  
ƒ
recommence this procedure from step 22.  
25. Switch off the electrical supply at the power outlet to the solar storage tank.  
The pump will deactivate.  
The closed circuit fluid will drain back down to the heat exchanger.  
26. Rectify any leaks in the solar pipe work and collector unions.  
If brazing is required to fix any leaks, then it is necessary to remove the solar circuit relief valve  
(refer to step 5).  
Warning: The solar circuit may be under pressure. Take care when removing the solar circuit  
relief valve, as a sudden discharge of pressurised hot air may be experienced. This discharge will  
create a sharp sound of air being released.  
27. If minor leaks have been rectified, recommence this procedure from step 22. If a major leak has  
been rectified, recommence this procedure from step 5.  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
COMMISSIONING  
Remove Closed Circuit Fluid Level Hose  
28. Remove the clear hose from the solar storage tank when satisfied the commissioning procedure is  
complete. To remove the hose:  
ƒ
ƒ
Ensure the heat exchanger drain valve is closed.  
heat  
exchanger  
drain valve  
closed  
Remove the hose from the side of the storage tank  
and place the end into a container to collect the  
closed circuit fluid remaining in the hose.  
ƒ
ƒ
Replace the plug into the free end of the hose and lay  
the hose flat on the ground.  
remove hose  
Loosen the hose clamp, if fitted, and carefully remove  
the hose and hose clamp from the heat exchanger  
drain valve fitting, ensuring there is no spillage of the  
closed circuit fluid.  
Clean up any spillage of closed circuit fluid.  
ƒ
Place the open end of the hose into the container and recover the remainder of the closed  
circuit fluid from the hose.  
Note: The closed circuit fluid contains food grade additives (rust inhibitor, anti-freeze agent,  
colour) and is harmless to the environment. However, it is good practice to recover any excess  
closed circuit fluid and remove from site.  
Completing the Commissioning of the Solar Circuit  
29. Reconnect the hot sensor lead to the connecting plug  
located on the tab in the upper front cover opening.  
It is important to reconnect the hot sensor lead,  
otherwise when the electrical supply is switched on, the  
solar pump will deactivate after one hour and the solar  
control unit will then enter a fault mode, will not operate  
and no solar gain will be achieved.  
reconnect  
hot sensor  
lead  
30. Replace the lower and upper front covers of the solar  
storage tank and the pipe cover to the underneath of  
the gas booster.  
31. Clean off the marks made on the side of the solar storage tank.  
32. Remove the covers from the solar collectors.  
33. Switch on the electrical supply at the power outlet to the solar storage tank.  
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COMMISSIONING  
DIAGNOSTIC FEATURES OF THE SOLAR CONTROLLER  
The solar storage tank incorporates an electronic solar control module. This is located inside of the  
lower front cover and houses both a green and a red LED. The LEDs emit either a constant glow or a  
series of flashes with a 2 second interval between flashes. The green LED indicates the current  
operational mode of the solar water heater and the red LED indicates a fault mode. To view the status  
of the LEDs, it is necessary to remove the lower front cover.  
Warning: The removal of the lower front cover will expose 240 V wiring. It must only be removed by  
an authorised or service person.  
The modes are:  
Flashes  
Operational Modes  
Solid green  
(remains on)  
Standby mode  
1 x green  
2 x green  
3 x green  
4 x green  
5 x green  
Flooding solar circuit  
Checking solar contribution  
Pump flow control  
Pump flow established  
Tank at maximum temperature  
Flashes  
1 x red  
2 x red  
3 x red  
4 x red  
Fault Modes  
Hot sensor in collector – open circuit  
Hot sensor in collector – short circuit  
Cold sensor – open or short circuit  
Top three tank thermistors – open or short circuit  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COMMISSIONING  
GAS INLET PRESSURE  
IMPORTANT - CHECK the gas supply pressure at the inlet to the water heater with the water heater  
and all other gas burning appliances in the premises operating (burners alight). The minimum gas  
supply pressure is:  
Natural Gas  
1.13 kPa  
Propane  
2.75 kPa  
If this minimum cannot be achieved, it may indicate the meter or the gas line to the water heater is  
undersized. It is important to ensure that an adequate gas supply pressure is available to the water  
heater when other gas burning appliances, on the same gas supply, are operating.  
It is necessary to remove the pipe cover from underneath the gas booster, by undoing the retaining  
screws, in order to test the gas pressure at the inlet of the gas booster. Refit the pipe cover at the  
completion of the installation.  
BURNER GAS PRESSURE  
It is necessary to check the burner gas pressure at both the minimum and maximum operational  
settings. It is necessary to have the electrical supply to the water heater switched on, the hot water  
must be flowing and the burners on to check and if necessary adjust the operational gas pressures.  
Warning: The removal of the front cover will expose 240 volt wiring. Take care not to touch wiring  
terminals.  
Ensure the burners are not operating. Close any hot taps and turn off the gas supply at the gas  
isolation valve.  
Remove the screws holding the front panel to the jacket.  
Gently disengage the front panel and pull forward to remove from the water heater.  
Locate the burner pressure test point on the main burner manifold and connect a manometer.  
Turn on the gas supply at the gas isolation valve.  
48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
COMMISSIONING  
Minimum test point gas pressure  
Refer to the rating label on the water heater for the minimum test point gas pressure.  
1. Open a hot tap slowly until the burners ignite.  
2. Press and hold down the MIN button (“1L” is shown  
on the LED display), and observe the reading on  
the manometer.  
L.E.D.  
display  
3. Release the MIN button. If the manometer reading  
observed in Step 2 agrees with the rating label, no  
further adjustment is required.  
test point  
orifice  
washer  
4. To adjust, press and hold down the adjuster button  
(“LH” is shown on the LED display).  
adjuster button  
max button  
Note: The adjuster button must be held down  
continuously through steps 4 to 6.  
min button  
manometer  
test point  
screw  
5. Press the MIN button and observe the reading on  
the manometer.  
Note: While the MIN button is pressed, the gas  
pressure will at first increase then decrease,  
cycling between an upper gas pressure limit (39 on  
LED display) and a lower gas pressure limit (01 on  
LED display).  
6. Release the MIN button when the reading on the manometer agrees with the rating label.  
7. Release the adjuster button.  
Notes:  
If the burners extinguish and / or an error code starts to flash on the display, release the MIN and  
adjuster buttons, close the hot tap, clear the error code, turn on the water heater and recommence  
the procedure from Step 1.  
If the adjuster button is released before Step 6, clear any error code (if displayed) and recommence  
the procedure from Step 1.  
To clear an error code, refer to “Error Codes” on page 16.  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COMMISSIONING  
Maximum test point gas pressure  
Refer to the rating label on the water heater for the maximum test point gas pressure.  
Follow Steps 1 to 7 of the “Minimum test point gas pressure” procedure, but open the hot tap fully and  
use the MAX button instead of the MIN button.  
Note: In Step 2, “3H” or “4H” will be shown on the LED display, depending on the model of the water  
heater.  
After setting the minimum and maximum test point gas pressures:  
Close the hot tap.  
Remove the manometer and refit and tighten the test point screw.  
Open a hot tap again so the burners ignite.  
Test for gas leaks.  
Refit the front panel and screws to the water heater.  
Close the hot tap.  
TO TURN OFF THE WATER HEATER  
If it is necessary to turn off the water heater on completion of the installation, such as on a building site  
or where the premises is vacant, then:  
Switch off the electrical supply at the power outlet to the water heater (refer to note below).  
Close the gas isolation valve at the inlet to the water heater.  
Close the cold water isolation valve at the inlet to the water heater.  
Drain the gas booster if there is a risk of freezing conditions occurring (refer to “Draining The Water  
Heater” on page 51).  
Note: The frost protection system of the gas booster will be rendered inoperable if electrical power is  
not available at the water heater. Damage caused by freezing due to the unavailability of power at the  
water heater is not covered by warranty (refer to “Warranty Exclusions” on page 53). If the power has  
been switched off to the water heater and there is a risk of freezing, then it is necessary to drain the gas  
50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
DRAINING THE WATER HEATER  
To drain the water heater:  
Gas Booster Water Heater  
Turn off the water heater (refer to “To Turn Off The Water Heater” on page 50).  
Open a hot tap (preferably the shower outlet).  
Unscrew the two drain plugs, one each at the cold water inlet and hot water outlet, on the  
underside of the gas booster.  
Water will drain from the gas booster.  
When water stops flowing from the gas booster, close the hot tap.  
Note: It is recommended not to screw the drain plugs back in, until the water heater is to be turned on  
again.  
Solar Storage Tank  
Turn off the water heater (refer to “To Turn Off The Water Heater” on page 50).  
Close all hot water taps.  
Operate the relief valve release lever - do not let the lever snap back or you will damage the valve  
seat.  
Operating the lever will release the pressure in the water heater.  
Undo the union at the cold water inlet to the solar storage tank and attach a hose to the water  
heater side of the union.  
Let the other end of the hose go to a drain.  
Operate the relief valve again.  
This will let air into the water heater and allow the water to drain through the hose.  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
WATER SUPPLIES  
Your water heater is manufactured to suit the water conditions of most Australian metropolitan supplies.  
However, there are some known water supplies which can have detrimental effects on the water heater  
and its operation and/or life expectancy. If you are unsure of your water quality, you can obtain  
information from your local water supply authority. The water heater should only be connected to a  
potable water supply.  
ANODE  
By using the correct colour coded anode this water heater can be used in areas where the total  
dissolved solids (TDS) content in the water is up to 2500 mg/L. In areas where the TDS exceeds  
600 mg/L it is possible the black anode, which is the standard anode fitted to the water heater, may be  
excessively active. To alleviate this, the black anode should be replaced with one colour coded blue.  
Where the TDS of the water is less than 40 mg/L, such as when the water has been deionised or is  
from an alpine supply, a high potential anode, colour coded green, should be used. The changing of  
anodes must be carried out by a plumber or authorised service person.  
CAUTION  
If your water supply has a TDS greater than 600 mg/L and the anode has not been changed to a blue  
one, there is the possibility hydrogen gas could accumulate in the top of the water heater during long  
periods of no use. In areas where this is likely to occur, the installer should instruct the householder on  
how to dissipate the gas safely.  
If, under these conditions, the water heater has not been used for two or more weeks the following  
procedure should be carried out before using any electrical appliances (automatic washing machines  
and dishwashers) which are connected to the hot water supply.  
The hydrogen, which is highly flammable, should be vented safely by opening a hot tap and allowing  
the water to flow. There should be no smoking or naked flame near the tap whilst it is turned on. Any  
hydrogen gas will be dissipated. This is indicated by an unusual spurting of the water from the tap.  
Once the water runs freely again, any hydrogen in the system will have been released.  
SATURATION INDEX  
The saturation index is used as a measure of the water’s corrosive or scaling properties. In a corrosive  
water supply, the water can attack copper parts and cause them to fail. Where the saturation index is  
less than –1.0, the water is corrosive.  
In a scaling water supply calcium carbonate is deposited out of the water onto any hot metallic surface.  
Where the saturation index exceeds +0.40, the water is scaling and an expansion control valve* must  
be fitted on the cold water line after the non-return valve.  
WATER HEATERS NOT INSTALLED IN ACCORDANCE WITH THE ABOVE ADVICE WILL NOT BE  
COVERED BY THE WARRANTY.  
52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SOLAHART STREAMLINE, SYNERGY, GAS BOOSTER  
SOLAR WATER HEATER WARRANTY – AUSTRALIA ONLY  
WARRANTY CONDITIONS  
1. This warranty is applicable only to water heaters manufactured  
from 1st July 2006.  
between the nearest Solahart Dealers premises and the installed  
site shall be the owners responsibility.  
2. The water heater must be installed in accordance with the 5. Where the water heater is installed in a position that does not  
Solahart water heater installation instructions, supplied with the  
water heater, and in accordance with all relevant statutory and  
local requirements of the State in which the water heater is  
installed.  
allow safe, ready access, the cost of accessing the site safely,  
including the cost of additional materials handling and / or safety  
equipment, shall be the owners responsibility.  
6. The warranty only applies to the water heater and original or  
genuine (company) component replacement parts and therefore  
does not cover any plumbing or electrical parts supplied by the  
installer and not an integral part of the water heater, e.g. pressure  
limiting valve; isolation valves; non-return valves; electrical  
switches; pumps or fuse.  
3. Where a failed component or water heater is replaced under  
warranty, the balance of the original warranty period will remain  
effective. The replaced part or water heater does not carry a new  
warranty.  
4. Where the water heater is installed outside the boundaries of a  
metropolitan area as defined by Solahart or further than 30 km 7. The water heater must be sized to supply the hot water demand  
from a regional Solahart Dealer from whom the water heater was  
purchased, the cost of transport, insurance and travelling costs  
in accordance with the guidelines in the Solahart water heater  
literature.  
WARRANTY EXCLUSIONS  
1. REPAIR AND REPLACEMENT WORK WILL BE CARRIED OUT AS SET OUT IN THE SOLAHART WATER HEATER  
WARRANTY, HOWEVER THE FOLLOWING EXCLUSIONS MAY CAUSE THE WATER HEATER WARRANTY TO  
BECOME VOID AND MAY INCUR A SERVICE CHARGE AND / OR COST OF PARTS.  
a) Accidental damage to the water heater or any component,  
including: Acts of God; failure due to misuse; incorrect  
installation; attempts to repair the water heater other than by the  
Solahart Dealer.  
or incorrectly mixed closed circuit fluid being used; a Streamline  
closed circuit system where there is insufficient or incorrect fall in  
the pipe work preventing complete drain back of the closed circuit  
fluid.  
b) Where it is found there is nothing wrong with the water heater; e) Where the electronic instantaneous gas booster water heater or  
where the complaint is related to excessive discharge from the  
temperature and / or pressure relief valve due to high water  
pressure; where the complaint is related to insufficient or  
incorrect fall in the pipe work preventing complete drain back of  
the closed circuit fluid of a Streamline closed circuit system;  
where there is no flow of hot water due to faulty plumbing; where  
water leaks are related to plumbing and not the water heater or  
water heater components; where there is a failure of gas,  
electronic instantaneous gas booster water heater component  
has failed directly or indirectly as a result of ice formation in the  
water ways of a water heater: where the water heater has not  
been installed in accordance with the water heater installation  
instructions; where the electricity has been switched off or has  
failed and the water heater has not been drained in accordance  
with the instructions; due to an ambient temperature below -20°C  
(including wind chill factor).  
electricity or water supplies; where the supply of gas, electricity or f) Where the water heater is located in a position that does not  
water does not comply with relevant codes or acts.  
comply with the Solahart water heater installation instructions or  
relevant statutory requirements, causing the need for major  
dismantling or removal of cupboards, doors or walls, or use of  
special equipment to bring the water heater to floor or ground  
level or to a serviceable position.  
c) Where the water heater or water heater component has failed  
directly or indirectly as a result of: excessive water pressure;  
excessive temperature and / or thermal input; blocked  
overflow / vent drain; corrosive atmosphere; non Solahart  
approved or incorrectly mixed closed circuit fluid being used; g) Repair and / or replacement of the water heater due to scale  
incorrect or insufficient filling of the closed circuit system with the  
closed circuit fluid; ice formation in the pipe work to or from the  
water heater.  
formation in the waterways or the effects of either corrosive water  
or water with a high chloride or low pH level when the water  
heater has been connected to a scaling or corrosive water supply  
or a water supply with a high chloride or low pH level as outlined  
in the Owner’s Guide and Installation Instructions booklet.  
d) Where the solar water heater or solar water heater component  
has failed directly or indirectly as a result of ice formation in the  
water ways of: a Streamline open circuit system; a Streamline h) Breakage of collector glass for any reason including hail damage.  
closed circuit system where the system has not been installed in  
accordance with the water heater installation instructions; a  
Streamline closed circuit system due to non Solahart approved  
(We suggest that the collector glass be covered by your home  
insurance policy).  
2. SUBJECT TO ANY STATUTORY PROVISIONS TO THE CONTRARY, THIS WARRANTY EXCLUDES ANY AND ALL  
CLAIMS FOR DAMAGE TO FURNITURE, CARPETS, WALLS, FOUNDATIONS OR ANY OTHER CONSEQUENTIAL  
LOSS EITHER DIRECTLY OR INDIRECTLY DUE TO LEAKAGE FROM THE WATER HEATER, OR DUE TO LEAKAGE  
FROM FITTINGS AND / OR PIPE WORK OF METAL, PLASTIC OR OTHER MATERIALS CAUSED BY WATER  
TEMPERATURE, WORKMANSHIP OR OTHER MODES OF FAILURE.  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
SOLAHART STREAMLINE, SYNERGY, GAS BOOSTER  
SOLAR WATER HEATER WARRANTY – AUSTRALIA ONLY  
WARRANTY  
Solahart* will:  
a) Repair or, if necessary replace any Solahart water heater; or  
b) Replace any component (or, if necessary, arrange the installation of a new water heater),  
which falls within the Warranty Periods specified below, subject to the warranty conditions and exclusions.  
Installation  
Model  
Period  
Warranty  
All Components (from date of installation)  
New component, solar collector or water heater (at  
Solaharts sole discretion), free of charge, including  
labour.**  
Year  
1
All installations  
All models  
Sealed System *** (from date of installation)  
Water heater installed in a  
single-family domestic dwelling”  
Year New sealed system component, free of charge, including  
Synergy  
2
labour.**  
Cylinder (from date of installation)  
Streamline,  
Streamline  
Years  
2 & 3  
New water heater, free of charge, including labour.**  
Water heater installed in a  
single-family domestic dwelling” Closed Circuit,  
Synergy  
Years New water heater, free of charge, with installation and  
4 & 5 labour costs being the responsibility of the owner.  
Streamline,  
Water heater installed in any other  
Streamline  
Years New water heater, free of charge, with installation and  
2 & 3 labour costs being the responsibility of the owner.  
than a  
Closed Circuit,  
single-family domestic dwelling”  
Synergy  
Heat Exchanger Electronic Instantaneous Gas Booster (from date of installation)  
Years  
2 & 3  
New heat exchanger, free of charge, including labour.**  
Water heater installed in a  
Streamline  
single-family domestic dwelling” Closed Circuit  
Years New heat exchanger, free of charge, with installation and  
4 & 5 labour costs being the responsibility of the owner.  
Solar Collector (from date of installation)  
L
J
KF  
Years New solar collector, free of charge, with installation and  
2 to 5 labour costs being the responsibility of the owner.  
All installations  
Notes:  
* Solahart is the supplier of Solahart electronic instantaneous solar gas booster water heaters, manufactured by Paloma  
Industries, a world leader in water heater technology and manufacture.  
** Refer to items 4 and 5 of warranty conditions.  
*** The Sealed System includes components that carry refrigerant only, e.g. Compressor, Condenser, TX Valve,  
Receiver/Drier, Evaporator and associated pipe work.  
Solahart reserves the right to transfer fully functional components from the defective water heater to the replacement water  
heater if required. The term water heater” used in the Warranty, Warranty Conditions and Warranty Exclusions means the  
Solahart supplied water heater(s), solar storage tank(s), solar collector(s), kit(s) and components.  
In addition to this warranty, the Trade Practices Act 1974 and similar laws in each state and territory provide the owner under  
certain circumstances with certain minimum statutory rights in relation to your Solahart water heater. This warranty must be  
read subject to that legislation and nothing in this warranty has the effect of excluding, restricting or modifying those rights.  
FOR SERVICE TELEPHONE  
SOLAHART INDUSTRIES PTY LTD  
Your Nearest Solahart Dealer or  
ABN 45 064 945 848  
1800 638 011 AUSTRALIA  
or refer local Yellow Pages  
Note: Every care has been taken to ensure accuracy in preparation of this publication. No liability can be accepted for any  
consequences, which may arise as a result of its application.  
54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SOLAHART INSTALLATION AND WARRANTY REPORT  
Dear Customer – To register your warranty please ensure the following information is correct  
then sign and return to our Solahart Industries Pty Ltd freepost address:  
Solahart Industries Pty Ltd.  
Reply Paid Perth 354,  
Welshpool, Western Australia 6106  
WARRANTY  
Details and conditions of warranty are in the “Water Heater Warranty” section of this manual.  
Please complete all details below  
Owner’s Name  
Installation Address  
Suburb  
State  
Country  
Postcode  
Telephone  
Solahart Dealership  
(H)  
(W)  
Consultant  
Installer’s Name  
Installation Date  
Type of Installation  
New  
Solar to Solar Tank Replacement  
Other  
(please circle)  
Work Delivery Details  
System Model No  
Tank Model No  
System Type  
Tank Serial No  
No of Collectors  
Collector Model No  
Collector Serial No’s  
1)  
2)  
3)  
4)  
Booster Type  
Electric  
continuous  
Off Peak 1  
(night)  
Off Peak 2  
(night & day)  
In-Tank Gas  
Booster  
In-Line  
Booster  
Solar Preheat  
only  
(please circle)  
Booster Control  
None  
Timer  
Manual Switch  
One Shot Control  
(please circle)  
In-Line Booster  
Model No  
Serial No  
(if installed)  
Service’s Due  
1)  
2)  
3)  
4)  
If replacing a water heater, please give details  
Brand  
Model No  
Electric  
Gas  
If a Solahart unit  
Tank Serial No  
Date of manufacture  
3) 4)  
Collector Serial No’s  
1)  
2)  
Comments  
Installer Certification – I certify this installation has been installed and tested in accordance with Solahart Industries Pty Ltd specifications  
Signature:  
Installer  
Customer  
Date  
White Copy: Head Office  
Yellow Copy: Dealer  
Blue Copy: Sales Office  
Green Copy: Manual  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SOLAHART OFFICES  
Corporate Headquarters  
112 Pilbara St  
Telephone International:  
Welshpool  
Western Australia 6106  
+ 61 8 9351 4600  
Facsimile International:  
+ 61 8 9351 4698  
Email:  
Postal Address:  
PO Box 95  
Internet:  
State Parcel Centre  
Welshpool WA 6986  
Australian Offices  
Western Australia  
Phone:  
New South Wales  
Phone:  
08 9351 4600  
08 9351 4635  
02 9684 9333  
02 9684 9187  
Facsimile:  
Facsimile:  
Queensland  
Phone:  
South Australia  
Phone:  
07 3255 5185  
07 3255 5189  
08 8262 7825  
08 8359 6004  
Facsimile:  
Facsimile:  
Victoria / Tasmania  
Phone:  
Northern Territory  
Phone:  
03 9212 8950  
03 9212 8940  
08 8947 0274  
08 8947 1944  
Facsimile  
Facsimile:  
International Offices  
Europe  
Rest of the World  
Phone International:  
Facsimile International:  
+ 31 492 579 696  
+ 31 492 579 694  
Phone International:  
Facsimile International:  
+ 61 8 9351 4600  
+ 61 8 9351 4698  
USA  
Phone International:  
Facsimile International:  
+ 1 334 260 1586  
+ 1 334 260 1514  
Revision Date: 2006 July  
126537A  
56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

PYLE Audio TV Mount PSW501SF User Guide
RCA Flat Panel Television 42PA30RQ User Guide
RCA VCR VR613HF User Guide
Samsung Flat Panel Television LC630 ZC User Guide
Sanyo Air Conditioner 42XH72R User Guide
Sanyo Clock Radio R227 User Guide
Scientific Atlanta Network Router Rosa User Guide
Sears Lawn Mower 91725148 User Guide
Sears Microwave Oven 85951 User Guide
Sears Oven 71381 User Guide