Renesas Computer Hardware FP 144G User Guide

H8S/2678 Series, H8S/2678R Series,  
H8S/2668 Series FP-144G/FP-144H  
User System Interface Cable  
(HS2678RECH61H)  
for E6000 Emulator  
User’s Manual  
HS2678RECH61HE(C)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
Thank you for purchasing this user system interface cable (HS2678RECH61H) for the Renesas’s  
original microcomputer H8S/2678 series, H8S/2678R series, H8S/2668 series.  
The HS2678RECH61H is a user system interface cable that connects an H8S/2678 series,  
H8S/2678R series, H8S/2668 series E6000 emulator (HS2678REPI61H; hereinafter referred to as  
the emulator) to the IC socket for a FP-144G/FP-144H package for the H8S/2678 series,  
H8S/2678R series, H8S/2668 series MCU on the user system.  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Section 1 Configuration  
CAUTION  
Use an IC149-144-045-B51 socket (manufactured by  
YAMAICHI ELECTRONICS CO., Ltd.) for the FP-144G/  
FP-144H package IC socket on the user system.  
Figure 1 shows the configuration of the HS2678RECH61H user system interface cable for the  
FP-144G/FP-144H package.  
Figure 1 HS2678RECH61H User System Interface Cable  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table 1 lists the HS2678RECH61H components. Please make sure you have all of these  
components when unpacking.  
Table 1  
HS2678RECH61H Components  
No. Component  
Quantity  
Remarks  
1
2
3
4
Cable body  
Cable head  
IC socket  
1
1
1
1
For the FP-144G/FP-144H package  
Socket cover  
For installing an FP-144G/FP-144H packaged  
MCU  
5
6
Screws (M2 x 12 mm)  
Screws (M2 x 8 mm)  
4
4
For fastening cable head with four flat washers  
For installing an FP-144G/FP-144H packaged  
MCU with four flat washers  
7
8
CTS screws (M3 x 6 mm)  
Documentation  
2
1
For fastening the emulator station  
User’s manual for HS2678RECH61H (this  
manual)  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Section 2 Connection Procedures  
2.1  
Connecting User System Interface Cable to Emulator Station  
WARNING  
Observe the precautions listed below. Failure to do so  
will result in a FIRE HAZARD and will damage the user  
system and the emulator product or will result in  
PERSONAL INJURY. The USER PROGRAM will be  
LOST.  
1. Always switch OFF the user system and the emulator  
product before the USER SYSTEM INTERFACE CABLE  
is connected to or removed from any part. Before  
connecting, make sure that pin 1 on both sides are  
correctly aligned.  
2. The user system interface cable dedicated to the  
emulator must be used.  
To connect the cable body to the emulator station, follow the instructions below.  
1. Make sure the user system and emulator station are turned off.  
CAUTION  
When connecting or removing the user system interface  
cable, apply force only in the direction suitable for  
connection or removal, while making sure not to bend or  
twist the cable or connectors. Otherwise, the connectors  
will be damaged.  
2. After making sure the direction of the cable body connector is correct, firmly insert the cable  
body connector into the emulator station socket, and fasten the emulator station with two CTS  
screw (M3 x 6 mm). (figure 2)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 2 Connecting User System Interface Cable to Emulator Station  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.2  
Connecting User System Interface Cable to User System  
WARNING  
Always switch OFF the user system and the emulator  
product before the USER SYSTEM INTERFACE CABLE  
is connected to or removed from any part. Before  
connecting, make sure that pin 1 on both sides are correctly  
aligned. Failure to do so will result in a FIRE HAZARD and  
will damage the user system and the emulator product or  
will result in PERSONAL INJURY. The USER PROGRAM will  
be LOST.  
To connect the cable head to the user system, follow the instructions below.  
2.2.1 Installing IC Socket  
After checking the location of pin 1 on the IC socket, apply epoxy resin adhesive to the bottom of  
the IC socket for an FP-144G/FP-144H package, and fasten it to the user system before soldering.  
2.2.2  
Soldering IC Socket  
After fastening, solder the IC socket for an FP-144G/FP-144H package to the user system. Be sure  
to completely solder the leads so that the solder slops gently over the leads and forms solder fillets.  
(Use slightly more solder than the MCU.)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2.2.3  
Inserting Cable Head  
CAUTION  
Check the location of pin 1 before inserting.  
Align pin 1 on the IC socket for a FP-144G/FP-144H system interface cable head into the IC socket  
on the user system, as shown in figure 3.  
2.2.4  
Fastening Cable Head  
CAUTION  
1. Use a Philips-type screwdriver whose head matches  
the screw head.  
2. The tightening torque must be 0.294 N•m or less.  
If the applied torque cannot be accurately measured,  
stop tightening when the force required to turn the screw  
becomes significantly greater than that needed when first  
tightening. If a screw is tightened too much, the screw  
head may break or an IC socket contact error may be  
caused by a crack in the IC socket solder.  
3. If the emulator does not operate correctly, cracks might  
have occurred in the solder. Check conduction with  
a tester and re-solder the IC socket if necessary.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Fasten the user system interface cable head to the IC socket for an FP-144G/FP-144H package on  
the user system with the four screws (M2 x 12 mm; with four flat washers) provided. Each screw  
should be tightened a little at a time, alternating between screws on opposing corners. Take special  
care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from  
being damaged by overtightening the screws or twisting the components.  
Figure 3 Connecting User System Interface Cable to User System  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.2.5  
Fastening Cable Body  
Connect the cable body to the cable head.  
Removing  
Cable body  
Push the unfastening jigs.  
unfastening jig  
Cable head  
User system  
Figure 4 Fastening Cable Body  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2.3  
Recommended Dimensions for User System Mount Pad  
Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with  
an IC socket for an FP-144G/FP-144H package (IC149-144-045-B51: manufactured by  
YAMAICHI ELECTRONICS CO., Ltd.). Note that the dimensions in figure 5 are somewhat  
different from those of the actual chip's mount pad.  
Figure 5 Recommended Dimensions for Mount Pad  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2.4  
Dimensions for User System Interface Cable Head  
The dimensions for the user system interface cable head are shown in figure 6.  
Figure 6 Dimensions for User System Interface Cable Head  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2.5  
Resulting Dimensions after Connecting User System Interface Cable  
The resulting dimensions, after connecting the user system interface cable head to the user system,  
are shown in figure 7.  
Figure 7 Resulting Dimensions after Connecting User System Interface Cable  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Section 3 Installing the MCU to the User System  
CAUTION  
1. Check the location of pin 1 before inserting.  
2. Use a Philips-type screwdriver whose head matches  
the screw head.  
3. The tightening torque must be 0.294 N•m or less.  
If the applied torque cannot be accurately measured,  
stop tightening when the force required to turn the screw  
becomes significantly greater than that needed when first  
tightening. If a screw is tightened too much, the screw  
head may break or an IC socket contact error may be  
caused by a crack in the IC socket solder.  
4. If the MCU does not operate correctly, cracks might have  
occurred in the solder. Check conduction with a tester  
and re-solder the IC socket if necessary.  
Check the location of pin 1 before inserting the MCU into the IC socket on the user system, as  
shown in figure 8. After inserting the MCU, fasten the socket cover with the provided four screws  
(M2 x 8 mm; with flat washers). Take special care, such as manually securing the IC socket  
soldered area, to prevent the IC socket from being damaged by overtightening the screws or twisting  
the components.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 8 Installing MCU to User System  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Section 4 Verifying Operation  
1. When using the E6000 emulator for the H8S/2678 Series, H8S/2678R Series, H8S/2668 Series,  
turn on the emulator according to the procedures described in the E6000 Series Emulator User's  
Manual (HS2000EPI61HE).  
2. Verify the user system interface cable connections by accessing the external memory and ports  
to check the bus states of the pins with the MEMORY_FILL command (emulator command). If  
an error is detected, recheck the soldered IC socket and the location of pin 1.  
3. The emulator connected to this user system interface cable supports two kinds of clock sources  
as the MCU clock: an emulator internal clock and an external clock on the user system. For  
details, refer to the Emulator Supplementary Information (HS2678REPI61HE).  
To use the emulator internal clock  
Select the clock in the emulator station as the system clock (φ), by using the CLOCK  
command (emulator command).  
To use the external clock on the user system  
Select target clock t or t2 with the CLOCK command (emulator command). Supply the  
external clock from the user system to the emulator by inputting the external clock from the  
EXTAL terminal on the cable head or connecting a crystal oscillator to the EXTAL and  
XTAL terminals. For details, refer to section, Clock Pulse Generator, in the H8S/2678  
Series, H8S/2678R Series, H8S/2668 Series Hardware Manual.  
Figure 9 shows the oscillator circuit on the user system interface cable.  
R1 1 M  
HCU04  
HCU04  
To E6000 emulator  
HCU04  
R2 270  
EXTAL XTAL  
Figure 9 Oscillator Circuit  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Section 5 Notice  
1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable  
head before inserting the cable head into the user system IC socket.  
2. The dimensions of the recommended mount pad for the user system IC socket are different from  
those of the MCU.  
3. This user system interface cable is specifically designed for the HS2678REPI61H emulator. Do  
not use this cable with any other emulator station.  
4. To prevent breaking of wires in the cable body, do not place heavy or sharp metal objects on the  
user system interface cable.  
5. While the emulator station is connected to the user system with the user system interface cable,  
force must not be applied to the cable head. Place the emulator station, user system interface  
cable, and user system as shown in the example in figure 10.  
Figure 10 User System Interface Cable Location Example  
6. The P1 jumper connector is used for testing. Do not remove the jumper pin inserted on pin 1  
side.  
Figure 11 P1 Short Connector  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Q Logic Switch IB6054601 00 D User Guide
QSC Audio Portable Speaker SC 424 User Guide
Radio Shack Headphones PRO 35A User Guide
RCA CRT Television TOCOM 1616332A User Guide
Roland DJ Equipment DJ 1000 User Guide
Rosewill Computer Drive RX30 User Guide
Samsung Projection Television HL R5056W User Guide
Sears Furnace 9MPD User Guide
Sega Video Game Console 999 1108 User Guide
Sennheiser Battery Charger L151 2 User Guide