Renesas Computer Hardware DP 64S User Guide

H8/3257 Series DP-64S  
User System Interface Cable  
(HS3257ECS61H)  
for E6000 Emulator  
User’s Manual  
Rev. 3.0  
4/1/03  
Renesas Technology Corp.  
HS3257ECS61HE(C)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
Thank you for purchasing the E6000 emulator for the Renesas’s original microcomputer H8/3257  
series.  
The HS3257ECS61H is a user system interface cable that connects an H8/300 series E6000  
emulator (HS3008EPI60H; hereinafter referred to as the emulator) to the IC socket for a DP-64S  
package for the H8/3257 series MCU on the user system.  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
Section 1 Configuration  
CAUTION  
Use an IC83-64075-GS4 socket (manufactured by  
YAMAICHI ELECTRONICS Co., Ltd.) for the DP-64S  
package IC socket on the user system.  
Figure 1 shows the configuration of the HS3257ECS61H user system interface cable for the  
DP-64S package.  
Figure 1 HS3257ECS61H User System Interface Cable  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table 1 lists the HS3257ECS61H components. Please make sure you have all of these  
components when unpacking.  
Table 1  
HS3257ECS61H Components  
No. Component  
Quantity  
Remarks  
1
2
3
4
Cable body  
Cable head  
IC socket  
1
1
2
1
Flat cable  
For protection of the DP-64S package  
Documentation  
User’s manual for HS3257ECS61H (this manual)  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Section 2 Connection Procedures  
2.1  
Connecting User System Interface Cable to Emulator Station  
WARNING  
Observe the precautions listed below. Failure to do so  
will result in a FIRE HAZARD and will damage the user  
system and the emulator product or will result in  
PERSONAL INJURY. The USER PROGRAM will be  
LOST.  
1. Always switch OFF the user system and the emulator  
product before the USER SYSTEM INTERFACE CABLE  
is connected to or removed from any part. Before  
connecting, make sure that pin 1 on both sides are  
correctly aligned.  
2. The user system interface cable dedicated to the  
emulator must be used.  
To connect the cable body to the emulator station, follow the instructions below.  
1. Make sure the user system and emulator station are turned off.  
CAUTION  
When connecting or removing the user system interface  
cable, apply force only in the direction suitable for  
connection or removal, while making sure not to bend or  
twist the cable or connectors. Otherwise, the connectors will  
be damaged.  
2. After making sure the direction of the cable body connector is correct, firmly insert the cable  
body connector into the emulator station socket (figure 2).  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Emulator station  
Figure 2 Connecting User System Interface Cable to Emulator Station  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.2  
Connecting User System Interface Cable to User System  
WARNING  
Always switch OFF the user system and the emulator  
product before the USER SYSTEM INTERFACE CABLE  
is connected to or removed from any part. Before  
connecting, make sure that pin 1 on both sides are correctly  
aligned. Failure to do so will result in a FIRE HAZARD and  
will damage the user system and the emulator product or  
will result in PERSONAL INJURY. The USER PROGRAM will  
be LOST.  
To connect the cable head to the user system, follow the instructions below.  
2.2.1 Installing IC Socket  
Prepare an IC socket (commercially available) for the DP-64S package and mount it on the user  
system.  
Recommended IC socket:  
IC83-64075-GS4  
manufactured by YAMAICHI ELECTRONICS Co., Ltd.  
2.2.2  
Inserting Cable Head  
CAUTION  
Check the location of pin 1 before inserting.  
Align pin 1 on the IC socket for a DP-64S package on the user system with pin 1 on the user  
system interface cable head, and insert the user system interface cable head into the IC socket on  
the user system, as shown in figure 3.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Pin 1  
Cable head  
IC socket  
(IC83-64075-GS4  
manufactured by  
YAMAICHI ELECTRONICS  
Co., Ltd.)  
User system  
Figure 3 Connecting User System Interface Cable to User System  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.2.3  
Fastening Cable Body  
Connect the cable body to the cable head.  
Figure 4 Fastening Cable Body  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2.3  
Dimensions for User System Interface Cable Head  
The dimensions for the user system interface cable head are shown in figure 4.  
Figure 5 Dimensions for User System Interface Cable Head  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2.4  
Resulting Dimensions after Connecting User System Interface Cable  
The resulting dimensions, after connecting the user system interface cable head to the user system,  
are shown in figure 5.  
IC83-64075-GS4  
IC83-64075-GS4  
Figure 6 Resulting Dimensions after Connecting User System Interface Cable  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Section 3 Verifying Operation  
1. When using the H8/300 series E6000 emulator (HS3008EPI60H), turn on the emulator  
according to the procedures described in the H8/300 Series E6000 Emulator User's Manual  
(HS3008EPI60HE).  
2. Verify the user system interface cable connections by accessing the external memory and ports  
to check the bus states of the pins. If an error is detected, recheck the soldered IC socket and  
the location of pin 1.  
3. The emulator connected to this user system interface cable supports two kinds of clock  
sources: an emulator internal clock and an external clock on user system. For details, refer to  
the H8/300 Series E6000 Emulator User's Manual (HS3008EPI60HE).  
To use the emulator internal clock  
Select the clock in the emulator station as the system clock (φ) by using the CLOCK  
command (emulator command).  
To use the external clock on the user system as the system clock  
Select target clock t with the CLOCK command (emulator command). Supply the external  
clock from the user system to the emulator. Insert a crystal oscillator into the EXTAL and  
XTAL terminals for the system clock. The system clock (φ) has the same frequency as the  
external clock.  
Figure 7 shows the oscillator circuit on the user system interface cable.  
R1 1 M  
HCU04  
HCU04  
R2 270  
To the emulator  
EXTAL  
XTAL  
Figure 7 Oscillator Circuit  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Section 4 Notice  
1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable  
head before inserting the cable head into the user system IC socket.  
2. This user system interface cable is specifically designed for the HS3008EPI60H emulator. Do  
not use this cable with any other emulator station.  
3. To prevent breaking of wires in the cable body, do not place heavy or sharp metal objects on  
the user system interface cable.  
4. While the emulator station is connected to the user system with the user system interface cable,  
force must not be applied to the cable head. Place the emulator station, user system interface  
cable, and user system as shown in the example in figure 7.  
Place components so that the cable  
body and cable head are parallel to the  
user system.  
Cable  
Emulator station  
Cable head is parallel  
to emulator station  
Cable head is parallel  
to user system  
User system  
Figure 8 User Cable Location Example  
5. The P1 jumper is used for testing. Do not remove the inserted jumper pin.  
Figure 9 P1 Jumper  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Radio Shack Pager PG 202 User Guide
Radio Shack Scanner 20 404 User Guide
Ratoc Systems Network Card REX SMA01F User Guide
Reebok Fitness Home Gym RBEX33190 User Guide
Regal Ware Microwave Oven K6725 User Guide
Rolls Royce Automobile 1004227 User Guide
Salton Toaster FAC200T User Guide
Samsung Fax Machine SF 6800 User Guide
Samsung Home Security System SCV 2080 User Guide
Senco Nail Gun FramePro 651 User Guide