Owners &
C33 Classic Freestanding Gas Stove
Installation Manual
Classic C33 model shown above features
optional gold plated door and gold legs.
MODELS: C33-NG3 Natural Gas
C33-LP3 Propane
WARNING:
FOR YOUR SAFETY
If the information in these instructions are not followed ex- What to do if you smell gas:
actly, afireorexplosionmayresultcausingpropertydamage,
personal injury or loss of life.
Do not try to light any appliance
Do not touch any electrical switch:
donotuseanyphoneinyourbuild-
ing.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas sup-
plier, call the fire department.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
918-511
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
11/08/07
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF CONTENTS
SAFETY LABEL
OPERATING INSTRUCTIONS
Serial No. Decal ............................................................4 Operating Instructions .................................................16
Lighting Procedure ......................................................16
Shutdown Procedure...................................................16
REQUIREMENTS
Maintenance Instructions ............................................16
Copy of the Lighting Plate instructions .......................17
MA Code - CO Detector
(for state of Massachusetts only) ..................................5
MAINTENANCE
INSTALLATION
General Vent Maintenance..........................................18
Thermopile / Thermocouple.........................................18
Before You Start ............................................................6
Aeration Adjustment ....................................................18
Important Message........................................................6
Pilot Adjustment...........................................................18
General Safety Information ...........................................6
Log Replacement ........................................................19
Installation Checklist......................................................6
Gold-plated Doors .......................................................19
Clearances to Combustibles .........................................7
Glass Replacement.....................................................19
Optional Fan Installation................................................7
Removing Valve Assembly ..........................................20
Pedestal Assembly........................................................8
Installing Valve Assembly ............................................20
Leg and Bottom Shield Assembly..................................9
Optional Outside Air ......................................................9
PARTS LIST
Draft Hood.....................................................................9
Venting ..........................................................................9
Gas Connection...........................................................10 Main Assembly ............................................................21
System Data................................................................10 Burner & Logs .............................................................22
High Elevation .............................................................10 Base Options...............................................................23
Gas Pipe Pressure Testing..........................................10
Installation of the DC Sparker .....................................11
WARRANTY
Test for Flue Spillage...................................................12
Log Set Installation......................................................12
Warranty......................................................................27
Safety Latch ................................................................13
Door Handle ................................................................13
Remote Control Installation.........................................13
Remote Wall Switch ....................................................13
Wall Thermostat Installation ........................................13
Final Check .................................................................13
Wiring Diagrams..........................................................14
Normal Operating Sounds of Gas Appliances.............15
Regency® CLASSIC C33-3 Freestanding Gas Stove
Download from Www.Somanuals.com. All Manuals Search And Download.
3
SAFETY LABEL
Thisisacopyofthelabelthataccompanieseach
CLASSIC Freestanding Gas Stove - Natural
Gas and Propane. We have printed a copy of
the contents here for your review. The safety
label is located on the back panel.
NOTE: Regency® units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is the
correct one.
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfitter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, flexible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA720 and a CO alarm
withbatterybackupinthesameroomwhere
the gas appliance is installed.
Regency® CLASSIC C33-3 Freestanding Gas Stove
Download from Www.Somanuals.com. All Manuals Search And Download.
4
REQUIREMENTS
MA Code - CO Detector
(for the State of Massachusetts only)
5.08: Modifications to NFPA-54, Chapter 10
(2) Revise 10.8.3 by adding the following additional requirements:
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for
residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than
seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall
be satisfied:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled
equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is
installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery
operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure
served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of
qualified licensed professionals for the installation of hard wired carbon monoxide detectors
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon
monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of
thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon
monoxide detector with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions
shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.
3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight
(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The
sign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL
OBSTRUCTIONS".
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation
unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR
5.08(2)(a)1 through 4.
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by
the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or
structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product
Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the
instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a
Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies
"special venting systems", the following requirements shall be satisfied by the manufacturer:
1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and
2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and
detailed installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions,
all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of
the installation.
Regency® CLASSIC C33-3 Freestanding Gas Stove
5
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
13) Installation and any repairs to this appliance
should be done by a qualified service person.
A professional service person should be called
to inspect this appliance annually. Make it a
practice to have all of your gas appliances
checked annually.
IMPORTANT MESSAGE
BEFORE YOU START
TheCLASSICFreestandingGasStovemustbe
installed in accordance with these instructions.
Carefully read all the instructions in this manual
first.Consultthe"authorityhavingjurisdiction"to
determine the need for a permit prior to starting
the installation.
Safeinstallationandoperationofthisappliance
requires common sense, however, we are
required by the Canadian Safety Standards
and ANSI Standards to make you aware of
the following:
14) Do not strike the glass door.
INSTALLATION AND REPAIR
SHOULD BE DONE BY A QUALI-
FIED SERVICE PERSON. THE
APPLIANCE SHOULD BE IN-
SPECTED BEFORE USE AND AT
LEAST ANNUALLY BY A PRO-
FESSIONAL SERVICE PERSON.
MORE FREQUENT CLEANING
MAY BE REQUIRED DUE TO EX-
CESSIVELINTFROMCARPETING,
BEDDING MATERIAL, ETC. IT IS
IMPERATIVE THAT CONTROL
COMPARTMENTS, BURNERS
AND CIRCULATING AIR PAS-
SAGEWAYS OF THE APPLIANCE
BE KEPT CLEAN.
15) Under no circumstances should any solid fuels
(wood, paper, cardboard, coal, etc.) be used in
this appliance.
GENERAL SAFETY
INFORMATION
1) The appliance installation must conform
with local codes or, in the absence of local
codes,withthecurrentCanadianorNational
Gas Codes, CAN1-B149 or ANSI Z223.1
Installation Codes.
16) The appliance area must be kept clear and
free of combustible materials, (gases and other
flammable vapours and liquids).
Emissions from burning wood or gas could
contain chemicals known to the State of Cali-
fornia to cause cancer, birth defects or other
reproductive harm.
2) The appliance when installed, must be
electrically grounded in accordance with
localcodes, orintheabsenceoflocalcodes
with the current National Electrical Code,
ANSI/NFPA 70 or CSA C22.1 Canadian
Electrical Code.
INSTALLATION
CHECKLIST
1) Locate appliance. Refer to the "Clearance to
3) This appliance is Listed for bedroom instal-
lations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
Combustible" section.
DUE TO HIGH TEMPERATURES,
THE APPLIANCE SHOULD BE
LOCATED OUT OF TRAFFIC AND
AWAY FROM FURNITURE AND
DRAPERIES.
2) Install Optional Fan. Refer to the "Optional Fan
Installation" section.
3) Assemble stove base - pedestal or legs. Refer
to "Pedestal Assembly" or "Leg and Bottom
Shield Assembly" section.
4) This appliance is Listed for Alcove instal-
lations, maintain minimum Alcove clear-
ances as follows, minimum ceiling height
of 65-11/16", minimum width of 48" and a
maximum depth of 36".
4) If using outside air. Refer to the "Optional
WARNING: FAILURE TO INSTALL
THIS APPLIANCE CORRECTLY
MAY CAUSE A SERIOUS HOUSE
FIREAND WILLVOIDYOUR WAR-
RANTY.
Outside Air" section.
5) This unit is not approved for installation into
5) Install venting. Refer to the "Venting" section.
a mobile home.
6) Make gas and electrical connections. Refer to
6) See general construction and assembly
the "Gas Connection" section.
instructions.
CHILDRENANDADULTSSHOULD
BE ALERTED TO THE HAZARDS
OF HIGH SURFACE TEMPERA-
TURES, ESPECIALLY THE FIRE-
PLACE GLASS, AND SHOULD
STAYAWAY TOAVOID BURNS OR
CLOTHING IGNITION.
Test the pilot. Must be as per diagram in the
"Pilot Adjustment" section.
7) This appliance must be connected to a vent
and terminate to the outside of the building
envelope. Never vent to another room or
inside a building.
7) Test gas pressure. Refer to the "Gas Pipe Pres-
sure Testing" section.
8) Inspect the venting system annually for
8) Test for flue spillage. Refer to the "Test for Fuel
blockage and any signs of deterioration.
Spillage" section.
9) Any safety glass removed for servicing
must be replaced prior to operating the ap-
pliance.
9) Install standard and optional features. Refer to
YOUNG CHILDREN SHOULD BE
CAREFULLY SUPERVISEDWHEN
THEY ARE IN THE SAME ROOM
AS THE APPLIANCE.
the following sections where applicable:
a. Log Set Installation
b. Remote Control
c. Remote Wall Switch
d. Wall Thermostat
10) To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the
fireplace.
CLOTHING OR OTHER FLAM-
MABLE MATERIAL SHOULD NOT
BE PLACED ON OR NEAR THE
APPLIANCE.
11) Wear gloves and safety glasses for protec-
11) Final check. Refer to the "Final Check" sec-
tion while doing required maintenance.
tion.
12) Under no circumstances should this ap-
pliance be modified. Parts that have to be
removed for servicing should be replaced
prior to operating this appliance.
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing cor-
rectly and operation fully explained to customer.
Regency® CLASSIC C33-3 Freestanding Gas Stove
6
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
4) Screw the four 8-32 x 3/4 screws provided
into the nutserts as shown in diagram 3. Do
not tighten screws.
This includes:
OPTIONAL FAN
INSTALLATION
Important: Disconnect the power
supply before installation or serv-
icing.
1) Clockingtheappliancetoensurethecorrect
firing rate (rate noted on label) after burning
appliance for 15 minutes.
5) Push all the fan wires through the hole on
the fan assembly. See diagram 2
.
6) Putpowercord(shownindiagram3)through
the hole and pull through to front of unit for
easier installation of ground wire.
2) If required, adjusting the primary air to
ensure that the flame does not carbon.
First allow the unit to burn for 15-20 min.
to stabilize.
3) Check for proper draft.
For pedestal unit: To install the fan in an in-
stalled stove-access from front through the
pedestal by following the directions below.
If the stove is not installed - access through
rear and follow steps 4 to 17.
CAUTION:Anyalterationtotheproductthat
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.
7) Place fan assembly partially in door cover
plate hole. See diagram 2.
8) Attach the 2 ground wires (green) to the
ground lug as per diagram 2.
CLEARANCES TO
COMBUSTIBLES
Note:Ground lug is located on the bottom of the
fan assembly. See diagram 2.
The clearances listed below are MINIMUM
distances. Measure the clearance to both the
appliance and the chimney connector. The far-
thestdistanceiscorrectifthetwoclearancesdo
notcoincide.Forexample,iftheapplianceisset
as indicated in one of the diagrams but the back
wallistooclose,movethestoveuntilthecorrect
clearance to the back wall is obtained.
Forlegunit:remove7screws, removebottom
access panel and install fan assembly and
follow steps 4 to 17.
Thisunitcanbeinstalledonasolidcombustible
surface like a wood floor. This unit can also be
installed directly on carpeting or vinyl when the
bottom pedestal cover plate (provided with the
unit) is installed.
1) Openpedestaldoorandremovedoorcover
plate by removing 4 screws. See diagram
1.
This appliance may be installed only with the
clearances as shown in the situations pictured.
Do not combine clearances from one type of
installation with another in order to achieve
closerclearances.Usetheminimumclearances
shown in the diagrams.Alcove installations are
approved, as long as side wall clearances are
maintained.
Diagram 3
9) Liftthefanassemblyinthroughthepedestal
and up through the cut out as shown in
diagrams 3 and 4.
10) Put the insulation gasket on the back of
the fan. Line up the keyhole slots with the
matching screws and pull back slightly to
lock into place. While holding fan assembly
in place, tighten screws.
C33-3 Clearances to Combustibles
A
B
E
Side Wall to Unit
Back Wall to Unit
Side Wall to Unit
10" / 250 mm
6" / 150 mm
1.5" / 38 mm
Diagram 1
2) Remove valve cover plate by removing 2
C33-3 Reference Dimensions
to Flue Centerline
screws.
3) Remove wire from piezo ignitor.
C
D
F
Back Wall
Side Wall
Side Wall
11-1/2"/ 292 mm
22" / 559 mm
13" / 330 mm
Minimumceilingheightis36"/914mmfrom
Diagram 4
Diagram 2
Regency® CLASSIC C33-3 Freestanding Gas Stove
Download from Www.Somanuals.com. All Manuals Search And Download.
7
INSTALLATION
16) Pull power wire back and put strain relief
Wiring
PEDESTAL ASSEMBLY
1) Foreasierassembly,tipthestoveonitsback
(preferably onto a soft surface to prevent
scratching).
grommet in place as per diagram 4.
11) Remove the dummy plug from the right side
of the bottom shield or pedestal and install
the supplied fan switch.
17) Reverse steps 3-1 to complete installa-
tion.
Note:The #8 ground lug is a dedicated
ground for mobile home use only.
12) Attach hot wire from power cord to the ther-
2) Unscrew the 4 bolts in the underside of the
stove. Align the holes in the corners of the
pedestaltopwiththecorrespondingholesin
the base of the stove. Use washers which
are supplied with the pedestal as shown in
diagram. Reinstall bolts.
modisc.
Only C34 unit is approved for mobile
homes.
13) Slide the thermodisc under the bracket.
Caution: Ensure that wires do
NOT touch hot surfaces.
Fan Removal
1) Disconnect the power to fan.
2) Allow the stove to cool to room tempera-
ture.
3) Open the pedestal door and remove the
screws on the door cover plate. Leg Units:
Remove bottom access panel.
4) Loosen the nutsert screws.
5) Remove Fan Assembly from the key slots
at the fan base. Take the fan out from the
rectangular opening . Diagram 3.
6) Turn the fan around 90 degrees (Pedestal
View from Bottom of Stove
units only). Diagram 2.
14) Connecting wires to the 3 way switch -
a. Connect the red wire from the fan to the
top of the 3 way switch.
7) Disconnect the green ground wires to the
grounding lug.
b. Connect black wire from fan to the bottom
of the 3 way switch.
8) Disconnect the white wire of the fan from
Diagram 1
the power cord.
c. Connect white jumper wire to middle of
the three way switch. See wiring diagram
below.
3) Hook up wires to Burner ON/OFF switch
and valve assembly (be careful not to pinch
wires). See Diagram 1.
9) Disconnect red wire and black wire (from
fan to Fan Switch).
15) Connectwhitewirefromfanmotortoneutral
10) Take fan out from the stove body. Diagram
4) Push the Regency® logo into the two holes
inthefrontbottomleftcornerofthepedestal
cover plate.
on the power cord.
Note: Any paint touch up should be done
prior to placing logo on pedestal.
Wiring Diagram
Regency® CLASSIC C33-3 Freestanding Gas Stove
8
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
IMPORTANT
OPTIONAL
LEG AND BOTTOM
SHIELD ASSEMBLY
Theseinstructionsapplytothesteelleg,painted
cast leg and the gold plated cast leg. It will be
easier to attach the legs to the stove if it is
tipped on its back (preferably on a soft surface
to prevent scratching).
OUTSIDE AIR
Read all instructions carefully before starting
the installation. Failure to follow these instruc-
tions may create a fire or other safety hazard,
and will void the warranty. Be sure to check the
venting and clearance to combustible require-
ments. Consultyourlocalbuildingcodesbefore
beginning installation.
If needed, outside air for combustion can be
brought in either through the bottom of the ped-
estal or through the rear plate of the pedestal.
Thepedestalcoverplatemustbeinstalledwhen
using outside combustion air. Loosen the 4
screws on the rear of the pedestal and slide the
cover plate over them. Slide the plate to the left
to center it and tighten down the 4 screws.
1) Remove the 4 bolts in the underside of the
base and discard.
DRAFT HOOD
2) Put the bottom shield up against the bottom
of the stove and loosely install the four sup-
plied bolts and washers into the threaded
holes in the four corners of the bottom the
unit. Once the bolts are started, slip the leg
under the washer and tighten the bolts.
The heater has a draft hood built into its back.
It must not be altered or obstructed, and the
unit must be installed so that the draft hood is
in the same atmospheric pressure zone as the
combustion air inlet to the burner.
Outside Air Through
Pedestal Bottom
Once you have properly marked the position
of your unit as outlined in "General Informa-
tion" and "Clearances to Combustibles", cut a
minimum 3 inch diameter hole though the floor
directly under your pedestal base to the outside.
Pipe fresh air into the pedestal area by using a
minimum 3" duct pipe with a mesh grill at the
outside termination.
3) HookupwirestoBurnerON/OFFswitchand
valve assembly as per pedestal assembly
diagram (diagram 1).
VENTING
This heater is a vented appliance and must be
connected to a chimney/flue in accordance with
installation codes.
4) Level the stove by adjusting the levelling
bolts in the bottom of each leg.
Note: Blanking plate combustion air hole is
4" diameter.
Note: The rear cover plate is only attached
when outside air is being used. Do
not install it when using room air for
combustion.
For your safety this heater is equipped with a
ventsafetyswitch.Thisthermallyactuatedswitch
is located within the draft hood and will detect
either a blocked chimney or backdraft condition
where the chimney flow has reversed and will
react by shutting off the gas supply.
Note: Thespillswitchismanuallyresettable
and comes from the factory in the
open position. Before trying to start
up the unit, make sure the red button
on the spill switch is pushed in.
Rear View
Outside Air Through
Pedestal Rear
Venting Requirements
Remove the blanking plate from the rear of the
pedestal cover plate and bend the two tabs out
90degrees.Pipefreshairintothepedestalarea
by using a minimum 3" duct pipe with a mesh
grill at the outside termination. Attach the pipe
to the tabs with screws.
Four inch diameter vent is required. B-Vent,
ClassAorMasonrywithalinerareallacceptable.
Follow all venting manufacturer’s requirements
and local building codes. For altitudes above
2000 ft. we recommend that a minimum flue
height of 12 ft. is used.
Note: The hole in the rear pedestal cover
plate is 4" diameter.
Note: Proper sizing of gas vents is critical
toproperoperationofallgasstoves
and fireplaces. Ensure that proper
sizing tables or vent manufacturers
instructions are followed.
Side View
Regency® CLASSIC C33-3 Freestanding Gas Stove
Download from Www.Somanuals.com. All Manuals Search And Download.
9
INSTALLATION
Installing into Existing
Woodstove Flue System
GAS PIPE
SYSTEM DATA
(For 0 to 2,000 feet altitude)
PRESSURE TESTING
1) Clean existing chimney system.
Orifice Sizes:
Burner
Burner
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shut-off valve during any pressure
testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig. (3.45
kPa). Disconnectpipingfromvalveatpressures
over 1/2 psig (14" w.c.).
Natural Gas
Propane
#36
#52
2) Install stove pipe adapter
3) Install any reducers that may be needed to
Max. Input Rating
Natural Gas
Propane
fit 6" flue pipe adapter.
33,000 Btu/h
33,000 Btu/h
4) Run 4" flex liner into existing chimney.
Min. Input Rating
Natural Gas
Propane
Themanifoldpressureiscontrolledbyaregulator
builtintothegascontrol, andshouldbechecked
at the pressure test point.
5) Slip liner through 6" flue pipe and hook up
17,000 Btu/h
17,000 Btu/h
to flue collar with screws.
Note: For ease of in-
stallation, use a
slip section when
installing
Output Capacity with blower Off
Note: Toproperlycheckgaspressure,both
inlet and manifold pressures should
be checked using the valve pressure
ports on the valve.
Natural Gas
Propane
23,200 Btu/h
23,100 Btu/h
with a ver-
Output Capacity with blower On
tical flue
pipe.
Natural Gas
Propane
24,600 Btu/h
24,420 Btu/h
1) Make sure the valve is in the "OFF" posi-
tion.
Supply Pressure
Natural Gas
min.
5.0" w.c
2) Loosen the "IN" and/or "OUT" pressure
tap(s), turning counterclockwise with a
1/8" wide flat screwdriver.
max. 8.0" w.c.
Propane
min.
12.0" w.c.
max. 13.0" w.c.
Manifold Pressure High
3) Attach manometer to "IN" and/or "OUT"
Natural Gas
Propane
3.8" +/- 0.2" w.c.
11" +/- 0.2" w.c.
pressure tap(s) using a 5/16" ID hose.
4) Light the pilot and turn the valve to "ON"
Manifold Pressure Low
position.
Natural Gas
Propane
1.1" +/- 0.2" w.c.
2.9" +/- 0.2" w.c.
5) The pressure check should be carried out
with the unit burning and the setting should
be within the limits specified on the safety
label.
Electrical: 120V, 1.13A, 60 Hz.
Circulation Fan: (optional) 2 speed
75/125 CFM.
GAS CONNECTION
Log Set: Ceramic fiber, 4 per set.
The gas connection is a 3/8" NPT rigid pipe.
The gas line can be rigid pipe or to make in-
stallation easier, use a listed flexible connector
and/or copper pipe if allowed by local codes.
For minimum and maximum supply pressure
see the System Data table below.
6) When finished reading manometer, turn
off the gas valve, disconnect the hose and
tighten the screw (clockwise) with a 1/8" flat
screwdriver. Screw should be snug, but do
not over tighten.
HIGH ELEVATION
This unit is approved in Canada for altitude 0
to 4500 ft. (CAN1 2.17-M90) with the orifice
supplied.
Note: During any pressure testing of the
gas supply piping system that ex-
ceedstestpressuresof1/2psig,this
appliance and its individual shut-off
valve must be disconnected from
the piping system. If test pressures
equaltoorlessthan1/2psigareused
then this appliance must be isolated
from the piping system by closing
its individual manual shut-off valve
during the testing.
SYSTEM DATA
(For 2,000 to 4,500 feet altitude)
Orifice Sizes:
Burner
Natural Gas
#38
Max. Input Rating
Natural Gas
29,000 Btu/h
15,300 Btu/h
Min. Input Rating
Natural Gas
Output capacity:
The efficiency rating of the appliance is a
product thermal efficiency rating determined
under continuous operating conditions and
was determined independently of any installed
system.
Output Capacity with blower Off
Natural Gas 20,400 Btu/h
Output Capacity with blower On
Natural Gas 21,600 Btu/h
Regency® CLASSIC C33-3 Freestanding Gas Stove
10
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
4) Loop the wires
throughtheheat
shield.
INSTALLATION OF THE
DC SPARKER
VALVE
DESCRIPTION
(APPLIES ONLY TO LP UNITS)
1) Gas on/off knob
2) Manual high/low adjustment
3) Pilot Adjustment
1) Attach the ground wire to the grounding
4) Thermocouple Connection
5) Main Operator
stub.
5) Installtheplasticbushingovertheoutsideof
the hole to protect the wires from the sharp
edges.
6) Outlet Pressure Tap
7) Inlet Pressure Tap
8) Pilot Outlet
9) Main Gas Outlet
10) Flange Securing Screw Holes
11) Alternative TC Connection Point
12) Thermoelectric Unit
13) Additional Valve Mounting Hole
Before
6a) Attach the ground wire to the DC spark
mounting bracket.
6b) Next,attachtheDCsparkergeneratorwires
to the DC sparker.
DC spark generating wires
After
2) Loop the 2 DC Spark generating wires as
well as the ground wire through the hole
provided.
With Pedestal:
ground wire
Piezo ignition wires
Select the hole to be used (depending
on which side you prefer to install the DC
Sparker box).
7) InstallthesuppliedbatteryintotheDCSparker
Box by opening the battery compartment.
NOTE: The battery in the DC Sparker Box
will need to be replaced annually.
Battery
Compartment
With Bottom Shield:
8) Attach the heat shield to the DC Sparker,
then mount onto either the Pedestal or the
Bottom Shield, using the velcro already
attached to the DC Sparker mounting
bracket.
3) AttachthePiezo
Ignition wire to
the DC Sparker
box.
Note: We recommend attaching the DC
sparker box to the bottom rear of the unit
(away from the heat source). Ensure this
a convenient location, easily accessible for
battery replacement.
Regency® CLASSIC C33-3 Freestanding Gas Stove
Download from Www.Somanuals.com. All Manuals Search And Download.
11
INSTALLATION
6) Place the cross logs on top of the larger
logs aligning the holes on the underside of
the cross log with the log pins in the larger
logs. See diagrams 1 & 2. Carefully push
the cross logs onto the pins.
TEST FOR
LOG SET
FLUE SPILLAGE
INSTALLATION
This heater must be properly connected to a
venting system.
WARNING: Dangerous operating condi-
tions may occur if these logs are not po-
sitioned in their approved locations. Read
the instructions below carefully and refer
to the diagrams. If logs are broken do not
use the unit until they are replaced. Broken
logs can interfere with the pilot and burner
WARNING:Operationofthisheater
when not connected to a properly
installed and maintained venting
system or tampering with the vent
safety shutoff system can result in
carbon monoxide (CO) poisoning
and possible death.
operation.
The gas log kit contains the following:
Diagram 2
a) Front Log
b) Rear Log
c) Small Cross Logs (2)
d) Bag of embers
e) Bag of rock wool
A “spillage” test must be made before the in-
stalled unit is left with the customer. Follow the
procedure below:
7) Distribute the embers along the mesh em-
ber tray, but do not cover the burner ports.
(Burnerportsarethelittleholesonthetopof
the burner tube.) Pull off ember size pieces
from the rock wool. Gently place the pieces
on top of the embers. See diagram 3.
1) Start all exhaust fans in the home and then
1) Removethelogsfromtheboxandcarefully
unwrapthem. Thelogsarefragile,handle
with care. Do not force into position.
close all doors and windows in the room.
2) Light the unit and set controls to maxi-
Do not put the rock wool directly on the
burner. Close the door and turn the unit on
asperlightinginstructions. Watchtheflame
to see if it flows smoothly around from one
end to the other. (Use Extreme Caution and
ensure proper light off of burner.)
mum.
2) Place the rear deflector on the rear log
support pins in the back of the unit.
3) Afterfiveminutes,testthatthereisa“pull”on
the flue by placing a smoke match, cigarette
or similar device which gives off smoke, on
the edge of the draft hood. See Diagram
below.
3) Place the rear log into the rear of the fire-
box, aligning the holes on the underside of
the log with the rear log support pins and
carefully push the log down onto the pins.
See diagrams 1 and 2.
The smoke should be drawn into the draft hood.
If the smoke is still not drawn into the draft hood,
turn the unit off and check for the cause of the
lack of draft. If necessary, seek expert advice.
4) Ensure the front deflector is over front log
pins. See diagram 1.
5) Place the front log in the front of the unit,
aligning the holes on the underside of the
log with the log support pins in the front of
the unit. Carefully push the log down onto
the pins. See diagram 1.
Note: If the flue is blocked or has a strong
reverse flow, the thermally actuated
safety switch mounted in the draft
hood will automatically shut off the
gas supply in less than 10 minutes.
If the heater turns off because of this
during the spillage test, check for
the cause of the lack of draft and if
necessary, seek expert advice.
Diagram 3
To reset the thermally actuated safety switch,
let the unit cool for 10 minutes, then press the
red reset button on the back of the switch. See
Diagram below.
8) If the flame hesitates at any point, check
the area of hesitation and see if there is an
emberorrockwoolblockingaburnerportor
ports. If so, move the obstruction and then
check the flame flow again.
Diagram 1
Regency® CLASSIC C33-3 Freestanding Gas Stove
12
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
SAFETY LATCH
Securedoorintheclosedpositionusingthedoor
securing bracket and the screw provided.
REMOTE CONTROL
INSTALLATION
WALL THERMOSTAT
INSTALLATION
UsetheRegency® RemoteControlKitapproved
for this unit. Use of other systems may void
your warranty.
Regency® offers an optional programmable
thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.
Connect the wires as per the wiring diagram.
Use the Thermostat Wire Table to determine the
maximum wire length.
1) Choose a convenient location on the wall
to install the receiver (protection from
extreme heat is very important). Run
wiresfromthefireplacetothatlocation. Use
the Thermostat Wire Table.
CAUTION
Do not wire the millivolt wall ther-
mostat wires to the 120V AC wires
Note: Preferableifthethermostatisinstalled
on an interior wall.
2) Connectthetwowirestothegasvalve. See
diagram below.
Thermostat Wire Table
CAUTION
Do not wire the millivolt remote
control wires to the 120V AC
wires.
Note: Door securing bracket is there for
safety.
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Note: The door must be kept closed at all
times, except during maintenance.
The unit must never be operated
without the glass in the door, or with
the door open.
3) Install3AAAalkalinebatteriesintransmitter
and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the remote receiver to "remote"
mode. The remote control is now ready for
operation.
Wire Size
Max. Length
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.
50 Ft.
32 Ft.
20 Ft.
12 Ft.
9 Ft.
DOOR HANDLE
Attach spring handle by rotating counter clock-
wise onto rod. Ensure that the spring fits into
the entire length of the rod.
REMOTE WALL
SWITCH
1) Run the wire through the opening in the
rear of the unit. Be careful not to damage
any wires.
FINAL CHECK
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly. This includes:
Note: We recommend a maximum of 15'
of wire but if you wish to go with a
longer run use the Thermostat Wire
Table.
1) Clocking the appliance to ensure the cor-
rect firing rate (rate noted on label) after 15
minutes.
2) Connect the wire to the wall switch and
2) Ifrequired,adjustingtheprimaryairtoensure
that the flame does not carbon. First allow
the unit to burn for 15 min. to stabilize.
install into receptacle box.
CAUTION
Do not wire the millivolt wall
switch for gas appliance to the
120V AC wires
3) Check for proper draft.
CAUTION: Any alteration to the product that
causes sooting or carboning that results in
damage to the unit is not the responsibility of
the manufacturer and will not be covered by
the warranty.
Regency® CLASSIC C33-3 Freestanding Gas Stove
13
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
WIRING DIAGRAMS
This heater does not require a 120V A.C. sup-
ply for operation. In case of a power failure, the
burner switch and the optional remote control/
thermostat will continue to operate. However,
a 120V A.C. power supply is needed for the
fan/blower operation.
Caution: Ensure that the wires do
not touch any hot surfaces and are
away from sharp edges.
CAUTION: Label all wires prior
to disconnection when servicing
controls. Wiring errors can cause
improper and dangerous opera-
tion.
For NATURAL GAS Units and Units NOT Equipped with DC Spark Boxes
WARNING: Electrical Grounding Instructions
This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should
be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from
this plug.
Regency® CLASSIC C33-3 Freestanding Gas Stove
Download from Www.Somanuals.com. All Manuals Search And Download.
14
INSTALLATION
For PROPANE Units and Units Equipped with DC Spark Boxes*
*For installation of the DC Spark Box refer to instructions in this manual.
NORMAL OPERATING SOUNDS OF GAS APPLIANCES
Itispossiblethatyouwillhearsomesoundsfrom
yourgasappliance.Thisisperfectlynormaldue
to the fact that there are various gauges and
typesofsteelusedwithinyourappliance.Listed
below are some examples. All are normal op-
erating sounds and should not be considered
as defects in your appliance.
Burner Tray:
Pilot Flame:
The burner tray is positioned directly under the
burner tube(s) and logs and is made of a differ-
ent gauge material from the rest of the firebox
and body. Therefore, the varying thicknesses
of steel will expand and contract at slightly
different rates which can cause "ticking" and
"cracking" sounds. You should also be aware
that as there are temperature changes within
theunitthesesoundswilllikelyre-occur.Again,
this is normal for steel fireboxes.
While the pilot flame is on it can make a
very slight "whisper" sound.
Gas Control Valve:
As the gas control valve turns ON and
OFF, a dull clicking sound may be audible,
this is normal operation of a gas regulator
or valve.
Blower:
Regency® gas appliances use high tech blow-
ers to push heated air farther into the room. It
is not unusual for the fan to make a "whirring"
sound when ON. This sound will increase or
decrease in volume depending on the speed
setting of your fan speed control.
Unit Body/Firebox:
Different types and thicknesses of steel
will expand and contract at different rates
resulting in some "cracking" and "ticking"
sounds will be heard throughout the cycling
process.
Blower Thermodisc:
When this thermally activated switch turns ON
itwillcreateasmall"clicking"sound.Thisisthe
switch contacts closing and is normal.
Regency® CLASSIC C33-3 Freestanding Gas Stove
Download from Www.Somanuals.com. All Manuals Search And Download.
15
OPERATING INSTRUCTIONS
MAINTENANCE
INSTRUCTIONS
OPERATING
INSTRUCTIONS
LIGHTING
PROCEDURE
1) Alwaysturnoffthegasvalvebeforecleaning.
For relighting, refer to lighting instructions.
Keep the burner and control compartment
clean by brushing and vacuuming at least
once a year.
1) The FIRST FIRE in your stove is part of the
paintcuringprocess.Toensurethatthepaint
is properly cured, it is recommended that
you burn your fireplace for at least four (4)
hours the first time you use it with the fan
on. Whenfirstoperated, theunitwillrelease
an odour caused by the curing of the paint
and the burning off of any oils remaining
from manufacturing. Smoke detectors in
the house may go off at this time. Open
a few windows to ventilate the room for a
coupleofhours.Theglasspanelmayrequire
cleaning.
NOTE: For all propane units and units
equipped with electric spark boxes,
see "Copy of Lighting Plate Instruc-
tions" section for more details.
IMPORTANT: Gas on/off knob cannot be
turned from "PILOT" to "OFF" unless it is
partially depressed.
When cleaning the logs, use a soft clean
brush as the logs are fragile and easily
damaged.
2) Clean appliance and door with a damp
cloth (never when unit is hot). Never use
an abrasive cleaner. The glass should be
cleaned with a gas fireplace glass cleaner
(when it starts to cloud up).
1) Turn burner OFF using "ON/OFF" switch.
2) Turn gas control knob so indicator points
to "OFF" position and allow 5 minutes for
any gas in the combustion chamber to
escape.
3) The heater is finished in a heat resistant
paint and should only be refinished with
heat resistant paint. Regency® uses Stove
Brite Paint - Metallic Black #6309.
Do Not Attempt To Clean The Glass While
it is still hot!
3) Turn gas control knob counterclockwise
so indicator points to the "PILOT" position.
Depress the gas control knob fully. Depress
the igniter button several times until the
pilot lights.After approximately one minute,
releasethegascontrolknob.Thepilotflame
should continue to burn. If the pilot does not
remainlit,repeatoperationallowingalonger
period before releasing gas control knob.
Note: When the glass is cold and the appli-
anceislit,itmaycausecondensation
andfogtheglass.Thiscondensation
is normal and will disappear in a few
minutes as the glass heats up.
4) Make a periodic check of burner for proper
position and condition. Visually check the
flameoftheburnerperiodically,makingsure
the flames are steady; not lifting or floating.
If there is a problem, call a qualified service
person.
DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.
4) When the pilot stays lit, turn the gas knob
further counterclockwise to the "ON" posi-
tion.
5) The appliance and venting system must be
inspectedbeforeuse, andatleastannually,
byaqualifiedfieldserviceperson,toensure
that the flow of combustion and ventilation
air is not obstructed.
2) Read and understand these instructions
5) UsetheON/OFFswitch,wallswitch,thermo-
before operating this appliance.
stat or remote control to turn on the unit.
3) Check to see that all wiring is correct and
During the annual service call, the burners
should be removed from the burner tray
and cleaned. Replace the embers and rock
wool.
6) Rotate the flame height regulator (Hi/Lo) to
enclosed to prevent possible shock.
adjust the flame height higher or lower.
4) Check to ensure there are no gas leaks.
5) Make sure the glass in the door frame is
properly positioned. Never operate the ap-
pliance with the glass removed.
SHUTDOWN
PROCEDURE
6) Each time the appliance is lit, it may cause
condensation and fog the glass. This con-
densation is normal and will disappear in
a few minutes as the glass heats up.
6) Verify that the venting is unobstructed.
1) Use the "ON/OFF" switch, wall switch,
thermostat or remote control to turn off the
burner.
7) Caution: Label all wires prior to discon-
nection when servicing controls. Wiring
errors can cause improper and dangerous
operation. Verify proper operation after
servicing.
7) Verify log placement. If the pilot cannot be
seen when lighting the unit - the logs have
been incorrectly positioned.
2) Push in the PILOT knob slightly and turn
clockwise to "OFF". Do not force.
8) The unit should never be turned off, and on
again without a minimum of a 60 second
wait for purging.
3) Turn off all electric power to the appliance
WARNING: CHILDREN AND
ADULTS SHOULD BE ALERTED
TO THE HAZARDS OF HIGH
SURFACE TEMPERATURES AND
SHOULD STAY AWAY TO AVOID
BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE
CAREFULLYSUPERVISEDWHEN
THEY ARE IN THE SAME ROOM
AS THE APPLIANCE.
if service is to be performed.
Regency® CLASSIC C33-3 Freestanding Gas Stove
Download from Www.Somanuals.com. All Manuals Search And Download.
16
OPERATING INSTRUCTIONS
COPY OF THE LIGHTING PLATE INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. (Australia: AS5601-2004, New Zealand: NZS 5261)
WARNING:Ifyoudonotfollowtheseinstructionsexactly,afireorexplosionmayresultcausingpropertydamage,
personal injury or loss of life. Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance
or additional information consult a qualified installer, service agency or gas supplier.
A) This appliance has a pilot which must be lighted by hand, following the instructions below exactly.
B) BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than
air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance
- Do not touch any electric switch, do not use any phone in your building
- Immediately call your gas supplier from a neighbors phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
C) Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to
repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
D) Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and
to replace any part of the control system and any gas control which has been under water.
E) This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.
CAUTION: Hot while in operation. Do not touch. Severe Burns may result. Due to high surface temperatures
keep children, clothing and furniture, gasoline and other liquids having fammable vapors away. Keep burner
and control compartment clean. See installation and operating instructions accompanying appliance.
LIGHTING INSTRUCTIONS
STOP! Read the safety information above on this label.
FOR UNITS NOT EQUIPPED WITH ELECTRIC SPARK:
FOR ALL PROPANE UNITS AND
UNITS EQUIPPED WITH ELECTRIC SPARK BOXES:
1) Push in gas control knob slightly and turn clockwise
to
“OFF”. Knob cannot be turned from “PILOT” to “OFF” unless
knob is pushed in slightly. Do not force.
1) Push in gas control knob slightly and turn to “PILOT” position.
OFF
PILOT BURNER
VEILLEUSE
2) Push in control knob all the way and hold in until the pilot lights
up. Continue to hold the control knob in for about 20 seconds
after the pilot is lit. Release knob.
THERMOPILE
Gas Inlet
ELEMENT
3) Push in gas control knob slightly and turn to "ON" position.
THERMO-
ELECTRIQUE
4) Turn ON the flame switch.
2) Wait five (5) minutes to clear out any gas. If you then smell gas
STOP! follow “B” in the safety information above on this label. If
you don’t smell gas, go to the next step.
Gas Inlet
3) Turn knob on gas control counterclockwise
to “PILOT”.
4) Push in control knob all the way and hold in. Immediately push
black button on spark igniter until pilot lights. Continue to hold the
control knob in for about 1/2 minute after the pilot is lit. Release
knob and it will pop back up. Pilot should remain lit. If it goes out,
repeat steps 3) and 4).
If knob does not pop up when released, stop and immediately call
your service technician or gas supplier.
If the pilot will not stay lit after several tries, turn the gas control
knob to “OFF” and call your service technician or gas supplier.
5) Turn gas control knob counterclockwise
6) Use rocker switch to operate main burner.
to “ON”.
TO TURN OFF GAS APPLIANCE
1) Turn off the flame switch.
2) Push in the gas control knob slightly and turn clockwise
to “OFF”. Do not force.
3) Turn off all electric power to the appliance if service is to be performed.
You may shut off the pilot during prolonged non use periods to conserve fuel.
DO NOT REMOVE THIS INSTRUCTION PLATE
918-474a
Regency® CLASSIC C33-3 Freestanding Gas Stove
Download from Www.Somanuals.com. All Manuals Search And Download.
17
MAINTENANCE
CAUTION:ANYSAFETYSCREEN
ORGUARDREMOVEDFORSERV-
ICING AN APPLIANCE MUST BE
REPLACED PRIOR TO OPERAT-
ING THE APPLIANCE.
THERMOPILE /
PILOT ADJUSTMENT
THERMOCOUPLE
Periodically check the pilot flames. Correct
flame pattern has three strong blue flames:
1 flowing around the thermopile, 1 around
the thermocouple and 1 flowing across the
burner (it does not have to be touching the
burner).
1) Loosenthethermocoupleorthermopilewith
a 7/16" wrench at bracket.
2) Disconnect thermocouple by loosening nut
from the valve with a 9mm wrench. Discon-
nect thermopile by loosening 2 screws
marked TP on the valve.
CLOTHING OR OTHER FLAM-
MABLE MATERIAL SHOULD NOT
BE PLACED ON OR NEAR THE
APPLIANCE.
Note: If you have an incorrect flame pat-
tern, contact your Regency® dealer
for further instructions.
3) Drop the thermocouple or thermopile down
from the bracket and pull it out of the unit.
NEVEROPERATETHEAPPLIANCE
WITHOUTTHEGLASSPROPERLY
SECURED IN PLACE.
4) Reinstall the new ones in reverse order.
AERATION
ADJUSTMENT
GENERAL VENT
MAINTENANCE
Conduct an inspection of the venting system
at least annually. Recommended areas to
inspect are:
The aeration adjustment rod is attached to the
air shutter on the burner. The air shutter adjust-
ment rod is located under the ashlip on the right
side. The rod is used to adjust the aeration on
the burner. This adjustment is performed by the
installer and is primarily used in installations at
high elevations. Push the rod in for a yellow
flame, or pull out on the rod for a bluer flame.
Top View of pilot flame
Incorrectflamepatternwillhavesmall,prob-
ably yellow flames, not coming into proper
contact with the rear burner or thermopile
or thermocouple.
1) Check areas of the Venting System which
are exposed to the elements for corrosion.
These will appear as rust spots or streaks,
and in extreme cases, holes. These com-
ponents should be replaced immediately.
Air shutter opening:
Natural Gas 7/16"
Propane
Wide open
2) Remove the Cap, and shine a flashlight
down the Vent. Remove any birds nests,
or other foreign material.
3) Checkforevidenceofexcessivecondensa-
tion, such as water droplets forming in the
liner, and subsequently dripping out the
joints, Continuous condensation can cause
corrosion of caps, pipe, and fittings. It may
becausedbyhavingexcessivelateralruns,
too many elbows, or exterior portions of the
system being exposed to cold weather.
Top View of pilot flame
4) Inspect joints, to verify that no pipe sections
or fittings have been disturbed, and conse-
quently loosened. Also check mechanical
supports such as Wall Straps for rigidity.
Closed - Tall Yellow flame
Open - Short Blue flame
Caution: Carbon will be produced if air shut-
ter is closed too much.
Note: Aeration Adjustment should only be
performedbyanauthorizedRegency®
Installer at the time of installation or
service.
Regency® CLASSIC C33-3 Freestanding Gas Stove
18
Download from Www.Somanuals.com. All Manuals Search And Download.
MAINTENANCE
7) Installthereplacementglass.Whenplacing
the replacement glass in the door, make
sure that the glass gasketing will properly
seal your unit.
LOG REPLACEMENT
GLASS
REPLACEMENT
The unit should never be used with broken
logs. Turn off the gas valve and allow the unit
tocoolbeforeopeningdoortocarefullyremove
the logs. The pilot light generates enough heat
to burn someone.
Your CLASSIC stove is supplied with high
temperature, 5 mm Neoceram ceramic glass
that will withstand the highest heat that your
unit will produce. In the event that you break
your glass by impact, purchase your replace-
mentglassfromanauthorizedRegency® dealer
only, and follow our step-by-step instructions
for replacement.
8) Put glass in place and then position glass
retainer rod.
Note: Do not use substitute materials. If
your glass does break, do not con-
tinuetouseyourunituntilithasbeen
replaced.
If for any reason a log should need replace-
ment, use only Regency® replacement logs.
The position of these logs must be as shown
in the diagram under Log Installation.
9) Position the glass retainer clips and door
securingbracket.Securetheglassretaining
screws but do not overtighten as this may
causetheglasstobreakaftertheunitheats
up.
1) Allow the stove to cool before removing or
NOTE: Improper positioning of logs may
create carbon build-up and will alter
the unit’s performance which is not
covered under warranty.
replacing glass.
2) To remove the door from the stove remove
thesecuringscrewlocatedbetweentheash-
lip and the door, then unfasten the latch.
10) Tighten all screws evenly.
3) Remove gold hinge caps from door.
4) Lift door off hinge.
GOLD-PLATED DOORS
Note: Donotovertightenasthismaycause
breakage.
The 24 carat gold plated finish on the door
requires little maintenance, and need only
be cleaned with a damp cloth. DO NOT use
abrasive materials or chemical cleaners, as
they may harm the finish and void the warranty.
Clean any fingerprints off before turning
the unit on.
11) Slip door over hinge pins.
5) Lay door on a soft, flat surface.
12) Put hinge caps back onto door.
6) Remove the screws in the glass retainer
clips and remove the glass retainer rod.
Remove any remaining pieces of glass
and ensure that the door is free of debris.
Use caution when removing broken glass
to avoid injury.
13) Close door and secure the security bracket
with the screw.
Regency® CLASSIC C33-3 Freestanding Gas Stove
19
Download from Www.Somanuals.com. All Manuals Search And Download.
MAINTENANCE
REMOVING
VALVE ASSEMBLY
1) Shut off gas supply.
2) Ifoptionalfanisinstalled,disconnectpower
source to stove.
3) Remove access panel.
a) Front panel on pedestal model. See
diagram 1.
b) Panel from bottom of leg shield. See
diagram 2.
Note: Access panel only has to be loos-
ened to be taken out.
16) Remove inlet pipe with pipe wrench. Note
8) Ifoptionalfanisinstalled,removethermodisc
tobracketbyremovingthree(3)phillipshead
M5 screws.
orientation of 90o elbow.
17) Remove two (2) phillips head M5 screws
on each side of the valve.
9) Remove front cover with Piezo Igniter by
removing two (2) sheet metal screws.
18) Removevalveandremovegasout90o brass
fitting. Note orientation of fitting.
10) Loosen four (4) phillips head M5 valve
mounting screws from underside of firebox.
Pushvalveassemblyforwardontheteardrop
slots and drop down. Diagram 3.
INSTALLING
VALVE ASSEMBLY
Diagram 1
1) To install a new valve assembly, reverse
instructions for removing valve. See as-
sembly steps 1-11.
2) Checkforleaksandmanifoldpressure.See
Gas Pressure Test instructions.
3) To reinstall valve, reverse instructions for
removing valve assembly, steps 12-18.
Diagram 3
11) Disconnect Piezo wire.
To remove valve from valve assembly,
continue.
Diagram 2
12) Remove two (2) thermopile wires.
4) Disconnect gas line to stove.
13) Removethermocouplewitha9mm(metric)
5) Disconnect 3/8" NPT pipe from 90o elbow
wrench.
on valve.
14) Remove pilot nut with an 11 mm wrench.
6) Disconnect the two (2) switch wires from
valve.
15) Remove valve to orifice nut with a 13/16"
wrench.
7) Removetwo(2)orificebracketscrewsinside
firebox.
Regency® CLASSIC C33-3 Freestanding Gas Stove
20
Download from Www.Somanuals.com. All Manuals Search And Download.
PARTS LIST
MAIN ASSEMBLY
Part #
Description
1)
850-141
850-142
850-143
850-144
Small Door - Black
Small Door - Gold
Small Door - Nickel Accent
Small Door - Gold Accent
850-151
850-152
850-153
850-154
Large Door - Black
Large Door - Gold
Large Door - Nickel Accent
Large Door - Gold Accent
3)
4)
5)
6)
7)
9)
846-302
936-243
846-920
*
Small Glass
Glass Gasket (7/8")
Glass Retainer Clips (8/set)
Screw 1/4 - 20 x 3/8"
Small Glass Retainer
Door Handle/Latch Assembly
Spill Switch
948-170/P
846-973
10) 910-250
12) 846-570
13) 846-918
7/8" Gasket Repair Kit
Hinge Cap - Gold (2/set)
Screw #10 - 24 x 3/4"
1/4" split lock washer
Screw #10 - 24 x 1/2"
Door Retainer Clip
14)
15)
16)
*
*
*
17) 471-031
19) 948-101
Spring Handle - Large
490-917
20) 910-157/P
22) 910-794
910-140
Fan Assembly (120 V) Optional
Fan motor (120 V)
Power Cord
Fan HI/OFF/LOW switch
Regency® CLASSIC C33-3 Freestanding Gas Stove
Download from Www.Somanuals.com. All Manuals Search And Download.
21
PARTS LIST
BURNER & LOGS
Part #
Description
52) 910-190
Piezo Ignitor & Nut
Control Panel
Control Panel Decal
53)
*
908-672
462-560/P
462-561/P
63) 910-478
66) 910-034
910-035
67) 904-604
904-390
68) 948-279
69) 948-294
70) 948-232
Valve Assembly - S.I.T. - NG
Valve Assembly - S.I.T. - LP
Valve S.I.T. - NG/LPG
Pilot Assembly-3 flame-S.I.T. -NG
Pilot Assembly-3 flame-S.I.T. -LP
Orifice #36 (NG)
Orifice #52 (LP)
Burner - LP
Burner - NG
Air Shutter Adjusting Rod
*
Burner Tray Assy-NG
Burner Tray Assy-LP
Deflector - Front Log
Deflector - Rear Burner Front
Deflector - Btm
*
72) 490-023
73) 460-009
74) 490-025
Burner/Rear Log (LP)
Rear Log Deflector Top
- Propane
75) 490-068
79) 460-011
Deflector - Rear Burner
Back (NG)
80)
81)
82)
*
*
*
Front Log
Rear Log
Top Log (each)
93) 904-537
3/8 x 12" black mall nipple.
*Not available as a replacement part.
Regency® CLASSIC C33-3 Freestanding Gas Stove
Download from Www.Somanuals.com. All Manuals Search And Download.
22
PARTS LIST
BASE OPTIONS
Part #
Description
Part #
Description
490-926
100) 948-216
948-223
Complete Pedestal
490-921
100) 948-216
948-223
Complete Floor Shield
Regency® Logo (Gold)
Regency® Logo (Silver)
Magnetic Catch (Large)
11" Pedestal Hinge
Regency® Logo (Gold)
Regency® Logo (Silver)
Magnetic Catch (Large)
11" Pedestal Hinge
102) 904-257
102) 904-257
103)
*
103)
*
108) 910-246
109) 910-272
Burner ON/OFF Switch (2-way)
LT. Dummy Plug
Strain Relief for power cord
Pedestal Blanking Plate
Pedestal Cover Plate
Rear Cover Plate
108) 910-246
109) 910-272
Burner ON/OFF Switch (2-way)
LT. Dummy Plug
110)
123)
*
*
110)
121)
*
*
Strain Relief for power cord
Access Panel
124) 820-058F
125)
*
140) 850-126
850-127
Cast Legs - Black
Cast Legs - Gold
*Not available as a replacement part.
850-128
Cast Legs - Brush Nickel
Regency® CLASSIC C33-3 Freestanding Gas Stove
Download from Www.Somanuals.com. All Manuals Search And Download.
23
NOTES
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
Regency® CLASSIC C33-3 Freestanding Gas Stove
Download from Www.Somanuals.com. All Manuals Search And Download.
24
NOTES
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
Regency® CLASSIC C33-3 Freestanding Gas Stove
Download from Www.Somanuals.com. All Manuals Search And Download.
25
NOTES
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
Regency® CLASSIC C33-3 Freestanding Gas Stove
Download from Www.Somanuals.com. All Manuals Search And Download.
26
WARRANTY
Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit
thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser
of a Regency Product. This warranty is not transferable.
The Warranty: Limited Lifetime
The combustion chamber, heat exchanger, burner tubes/pans, logs and gold plating (against defective manufacture only) are covered under the Limited Lifetime War-
ranty for five (5) years for parts and subsidized labour* and parts only thereafter.
Glass is covered for lifetime against thermal breakage only, parts and subsidized labour* for five (5) years and parts only thereafter from date of purchase.
Special Finishes - One year on brushed nickel, louvers and doors. You can expect some changes in color as the product "ages" with constant heating and cooling. FPI
warranties the product for any manufacturing defects on the original product. However, the manufacturers warranty does not cover changing colors and marks, ie. finger
prints, etc applied after the purchase of the product. Damage from the use of abrasive cleaners is not covered by warranty.
Electrical and mechanical components such as blowers, switches, wiring, thermodiscs, FPI remote controls, spill switches, thermopiles, thermocouples, pilot assembly
components, and gas valves are covered for two years parts and one year subsidized labour* from the date of purchase. Blowers and valves replaced under warranty
are considered repairs and continue as if new with appliance. ie. twelve (12) months from original purchase date of appliance with a minimum of three (3) months cover-
age from date of replacement.
FPI venting components (Direct Vent units) are covered parts and subsidized labour* for three (3) years from date of purchase.
Simpson Dura-Vent venting components (Direct Vent units) are covered by Simpson Dura-Vent Inc. warranty.
Repair/replacement parts purchased by the consumer from FPI after the original coverage has expired on the unit will carry a 90 day warranty, valid with a receipt only.
Any item shown to be defective will be repaired or replaced at our discretion. No labor coverage is included with these parts.
Conditions:
Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI's option, through an accredited distributor or agent
provided that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.
It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evalu-
ated for manufacturer defect.
The authorized selling dealer is responsible for all in-field service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship
from unauthorized service persons or dealers.
At all times FPI reserves the right to inspect product in the field which is claimed to be defective.
All claims must be submitted to FPI by authorized selling dealers. It is essential that all submitted claims provide all of the necessary information including customer
name, purchase date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.
Exclusions:
This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim.
At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once
manufactured. ie. as products evolve, field modifications or upgrades will not be performed.
FPI will not be liable for travel costs for service work.
Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the terms of this warranty policy.
Embers, glass and door gaskets, door handles and paint are not covered under the terms of this warranty policy.
Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.
The warranty will not extend to any part which has been tampered with or altered in any way, or in our judgment has been subject to misuse, improper installation,
negligence or accident, spillage or downdrafts caused by environmental or geographical conditions, inadequate ventilation, excessive offsets, negative air pressure
caused by mechanical systems such as furnaces, fans, clothes dryer, etc.
Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer.
FPI will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.
Performance problems due to operator error will not be covered by this warranty policy.
Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from FPI, may nullify your
warranty on this product.
Any alteration to the unit which causes sooting or carboning that results in damage to the interior / exterior facia is not the responsibility of FPI.
* Subsidy according to job scale as predetermined by FPI.
Regency® CLASSIC C33-3 Freestanding Gas Stove
Download from Www.Somanuals.com. All Manuals Search And Download.
27
Regency® fireplaceproductsaredesignedwith
reliability and simplicity in mind. In addition,
our internal Quality Assurance Team care-
fullyinspectseachunitthoroughlybefore
it leaves our door.
FireplaceProductsInternationalLtd.
is pleased to extend this
LimitedLifetimeWarrantytotheoriginal
purchaser of a Regency® Product.
See the inside back cover for details.
Register your Regency® online at
Installer: Please complete the following information
Dealer Name & Address:______________________________________________
___________________________________________________________________
Installer: ___________________________________________________________
Phone #: ___________________________________________________________
Date Installed: ______________________________________________________
Serial No.:__________________________________________________________
Regency and Classic are trademarks of FPI Fireplace Products International Ltd.
© Copyright 2007, FPI Fireplace Products International Ltd. All rights reserved.
Printed in Canada
Download from Www.Somanuals.com. All Manuals Search And Download.
|