Regency Indoor Fireplace P48 1 User Guide

Owners &  
Installation Manual  
P48-1 Gas Fireplace  
MODELS: P48-NG1 Natural Gas P48-LP1 Propane  
WARNING:  
FOR YOUR SAFETY  
Iftheinformationintheseinstructionsarenotfollowedexactly, What to do if you smell gas:  
a fire or explosion may result causing property damage,  
personal injury or loss of life.  
Do not try to light any appliance  
Do not touch any electrical switch:  
do not use any phone in your  
building.  
Immediately call your gas supplier  
from a neighbour's phone. Follow  
the gas supplier's instructions.  
If you cannot reach your gas  
supplier, call the fire department.  
FOR YOUR SAFETY  
Do not store or use gasoline or other flammable vapors and  
liquids in the vicinity of this or any other appliance.  
Installation and service must be performed by a qualified  
installer, service agency or the gas supplier.  
Tested by:  
Installer: Please complete the details on the back cover  
and leave this manual with the homeowner.  
Homeowner: Please keep these instructions for future reference.  
09/28/05  
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4  
918-458  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
Page  
Page  
FlushTrim .................................................................28  
BayDoor...................................................................29  
Bay Trim ...................................................................29  
BayLouvers ..............................................................29  
FinishingTrim ...........................................................30  
DoubleScreenDoor ..................................................30  
RemoteControl(optional) ..........................................31  
Remote Wall Switch (optional) ..................................31  
WallThermostat(optional) ........................................31  
WiringDiagram .........................................................32  
OptionalFan .............................................................33  
ConversiontoPropane ..............................................34  
Safety Label  
SafetyLabel ............................................................... 4  
Installation  
ImportantMessage .................................................... 5  
Before You Start ........................................................ 5  
GeneralSafetyInformation ......................................... 5  
Installation Checklist .................................................. 5  
ManufacturedMobileHome  
AdditionalRequirements ...................................... 6  
UnitSpecifications ..................................................... 6  
LocatingYourStove ................................................... 6  
Optional Duct System Kit .......................................... 6  
Optional Heat Release Kit .......................................... 6  
Hearth ..................................................................... 6  
Clearances ................................................................. 7  
Mantels ..................................................................... 8  
MantelLegClearances............................................... 8  
FramingandFinishing ................................................ 9  
Top Assembly & Nailing Strips..................................10  
VentingIntroduction ..................................................10  
ExteriorVentTerminationLocations..........................11  
VentingArrangements  
Operating Instructions  
OperatingInstructions ...............................................35  
LightingProcedure ....................................................35  
ShutdownProcedure .................................................35  
First Fire ...................................................................35  
AerationAdjustment..................................................35  
NormalOperatingSoundsof  
Gas Appliances ..................................................36  
Lighting Plate Instructions .........................................36  
Maintenance  
HorizontalTerminations ......................................12  
SimpsonDura-VentComponentsList .................13  
HorizontalTerminations ......................................14  
HorizontalVenting ..............................................15  
Vertical Venting ..................................................16  
VerticalTerminations ..........................................18  
Venting-Dura-VentHorizontalInstallations ..............20  
Venting-Dura-VentVerticalTermination...................21  
Direct Vent System (Flex).........................................22  
System Data .............................................................23  
HighElevation ...........................................................23  
Gas Line Installation..................................................23  
Pilot Adjustment .......................................................23  
Gas Pipe Pressure Test ............................................23  
SITValveDescription ................................................23  
Brick Panel Installation..............................................24  
Log Set Installation ...................................................25  
StandardFlushDoor .................................................28  
FlushLouvers ............................................................28  
MaintenanceInstructions ..........................................37  
GeneralVentMaintenance ........................................37  
LogReplacement ......................................................37  
Thermopile/Thermocouple .........................................37  
Glass Gasket............................................................37  
Gold-PlatedLouvers ..................................................37  
DoorGlass................................................................38  
Bay Glass Replacement ...........................................38  
InstallingValve ..........................................................38  
RemovingValve .........................................................39  
PartsList  
Replacement/SparePartsList...................................40  
Warranty  
Warranty ...................................................................47  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY LABEL  
Thisisacopyofthelabelthataccompanieseach  
P48-NG1 and P48-LP1 Zero Clearance Direct  
Vent Gas Fireplace. We have printed a copy of  
the contents here for your review. The safety  
label is located on the front inside base of the  
unit, visible when the bottom louver is open.  
NOTE: Regency units are constantly being im-  
proved. Check the label on the unit and if there  
is a difference, the label on the unit is the correct  
one.  
For the State of Massachusetts, installation  
and repair must be done by a plumber or  
gasfitter licensed in the Commonwealth of  
Massachusetts.  
For the State of Massachusetts, flexible  
connectors shall not exceed 36 inches in  
length.  
For the State of Massachusetts, the appli-  
ances individual manual shut-off must be a  
t-handle type valve.  
4
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
annually. Make it a practice to have all of  
your gas appliances checked annually.  
IMPORTANT:  
SAVE THESE  
INSTRUCTIONS  
YOUNG CHILDREN SHOULD BE  
CAREFULLY SUPERVISEDWHEN  
THEYAREINTHESAMEROOMAS  
THEAPPLIANCE.  
13) Do not slam shut or strike the glass door.  
14) Under no circumstances should any solid  
fuels (wood, paper, cardboard, coal, etc.)  
be used in this appliance.  
The P48-NG1/P48-LP1 Direct Vent Fireplace  
must be installed in accordance with these in-  
structions. Carefully read all the instructions in  
this manual first. Consult the "authority having  
jurisdiction" to determine the need for a permit  
prior to starting the installation. It is the responsi-  
bility of the installer to ensure this fireplace is  
installed in compliance with manufacturers in-  
structions and all applicable codes.  
CLOTHING OR OTHER FLAMMA-  
BLEMATERIALSHOULDNOTBE  
PLACEDONORNEARTHEAPPLI-  
ANCE.  
15) The appliance area must be kept clear and  
free of combustible materials, (gases and  
other flammable vapours and liquids).  
Emissions from burning wood or gas could  
contain chemicals known to the State of  
California to cause cancer, birth defects or  
other reproductive harm.  
GENERAL SAFETY  
INFORMATION  
BEFORE YOU START  
1) The appliance installation must conform  
with local codes or, in the absence of local  
codes, with the current Canadian or Nation-  
al Gas Codes, CAN1-B149 or ANSI Z223.1  
Installation Codes.  
Safeinstallationandoperationofthisappliance  
requires common sense, however, we are  
required by the Canadian Safety Standards  
and ANSI Standards to make you aware of the  
following:  
INSTALLATION  
CHECKLIST  
2) Theappliancewheninstalled, mustbeelec-  
trically grounded in accordance with local  
codes, or in the absence of local codes with  
the current National Electrical Code, ANSI/  
NFPA70orCSAC22.1CanadianElectrical  
Code.  
1) Locate appliance  
INSTALLATION AND REPAIR  
SHOULDBEDONEBYANAUTHOR-  
IZEDSERVICEPERSON. THEAP-  
PLIANCESHOULDBEINSPECTED  
BEFOREUSEANDATLEASTAN-  
NUALLY BY A PROFESSIONAL  
SERVICE PERSON. MORE FRE-  
QUENT CLEANING MAY BE RE-  
QUIREDDUETOEXCESSIVELINT  
FROMCARPETING,BEDDINGMA-  
TERIAL, ETC. IT IS IMPERATIVE  
THAT CONTROL COMPART-  
MENTS,BURNERSANDCIRCULAT-  
ING AIR PASSAGEWAYS OF THE  
APPLIANCEBEKEPTCLEAN.  
a) Room location, page 6  
b) Clearances to Combustibles, page 7  
c) Mantel Clearances, page 8  
d) Framing & Finishing Requirements,  
page 9  
3) See general construction and assembly  
instructions. The appliance and vent should  
be enclosed.  
e) Venting Requirements, pages 10-18.  
2) Assemble Top Facing Support and Side  
Nailing Strips, page 10.  
4) This appliance must be connected to the  
specified vent and termination cap to the  
outsideofthebuildingenvelope.Nevervent  
to another room or inside a building. Make  
sure that the vent is fitted as per Venting  
instructions.  
NOTE: must be done before installing  
unit into fireplace.  
3) Install venting, pages 20-21.  
4) Make gas and electrical connections. Test  
the pilot. Must be as per diagram. Page 23.  
5) Inspect the venting system annually for  
blockage and any signs of deterioration.  
5) Test Gas Pressure. Page 23.  
6) Venting terminals shall not be recessed into  
a wall or siding.  
6) Install brick panels (optional), page 24.  
DUE TO HIGH TEMPERATURES,  
THEAPPLIANCESHOULDBELO-  
CATED OUT OF TRAFFIC AND  
AWAY FROM FURNITURE AND  
DRAPERIES.  
7) Any safety glass removed for servicing  
must be replaced prior to operating the  
appliance.  
7) Install Flush Door Front (Standard) and  
optional Flush Gold Trim, page 28.  
8) Install Optional Bay Front and optional Bay  
8) To prevent injury, do not allow anyone who  
is unfamiliar with the operation to use the  
fireplace.  
Gold Trim, page 29.  
9) Install Louvers (Flush or Bay), pages  
WARNING:FAILURETOINSTALL  
THIS APPLIANCE CORRECTLY  
WILLVOIDYOURWARRANTYAND  
MAY CAUSE A SERIOUS HOUSE  
FIRE.  
28-29.  
9) Wear gloves and safety glasses for pro-  
tection while doing required maintenance.  
10) Installationof WallSwitch,RemoteControl,  
or Wall Thermostat, page 31.  
10) Be aware of electrical wiring locations in  
walls and ceilings when cutting holes for  
termination.  
11) Final check.  
CHILDRENANDADULTSSHOULD  
BE ALERTED TO THE HAZARDS  
OF HIGH SURFACE TEMPERA-  
TURES, ESPECIALLY THE FIRE-  
PLACE GLASS, AND SHOULD  
STAYAWAYTOAVOIDBURNSOR  
CLOTHINGIGNITION.  
11) Under no circumstances should this appli-  
ance be modified. Parts that have to be  
removed for servicing should be replaced  
prior to operating this appliance.  
Before leaving this unit with the customer, the  
installer must ensure that the appliance is firing  
correctly and operation fully explained to  
customer.  
12) Installationandanyrepairstothisappliance  
should be done by an authorized service  
person. A professional service person  
should be called to inspect this appliance  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
INSTALLATION  
This includes:  
LOCATING YOUR  
GAS STOVE  
1) Clocking the appliance to ensure the correct  
firing rate (rate noted on label 51,000 (NG)  
Btu/h, 48,000 (LP) Btu/h) after burning ap-  
pliance for 15 minutes.  
1) When selecting a location for your stove,  
ensure that the clearances outlined on this  
page are met.  
OPTIONAL  
DUCT SYSTEM  
KIT #946-556  
2) If required, adjusting the primary air to en-  
sure that the flame does not carbon. First  
allow the unit to burn for 15-20 min. to  
stabilize.  
2) Provide adequate clearances for servic-  
ing.  
CAUTION: Any alteration to the product  
that causes sooting or carboning that  
results in damage is not the responsibil-  
The HeatWave Air Duct Kit increases the  
effectiveness of your fireplace by dispersing  
warm air from the fireplace to remote locations  
in the same room or other rooms in your home.  
3) The appliance must be installed on a flat,  
solid, continuous surface (e.g. wood, met-  
al, concrete). This may be the floor, or  
raised up on a platform to enhance its  
visualimpact. Iftheapplianceisgoingtobe  
installed on carpeting, combustible linole-  
um tile or other combustible material other  
than wood flooring, the appliance must be  
installed on a metal or wood panel extend-  
ing the full width and depth of the appli-  
ance.  
ity of the manufacturer.  
Up to two kits may be installed on the fireplace.  
Please Note: Only 1 HeatWave kit may be  
operated at one time. This includes the internal  
blower option as well.  
MANUFACTURED  
MOBILE HOME  
ADDITIONAL  
REQUIREMENTS  
OPTIONAL  
HEAT RELEASE  
KIT #946-570  
4) The P48-1 Direct Vent Gas Fireplace can  
beinstalledinarecessedpositionorframed  
out into the room as in A, B, C, D. See  
Diagram 1.  
1) Ensure that structural members are not cut  
or weakened during installation.  
2) Ensure proper grounding using the #8  
The Heat Release Kit expels warm air from the  
fireplace to the outside of the building, allowing  
the fireplace to be operated with less heat  
enteringtheroom.Thekitmaybeusedoneither  
the left or right side.  
ground lug provided. See page 32.  
Diagram 1  
A) Flat on Wall  
B) Flat on Wall Corner  
C) Recessed into  
Wall/Alcove  
UNIT SPECIFICATIONS  
HEARTH  
D) Corner  
A hearth is not mandatory, but is recommended  
for aesthetics and for added safety.  
5) ThisapplianceisListedforbedroom instal-  
lations when used with a Listed Millivolt  
Thermostat. Some areas may have further  
requirements, check local codes before  
installation.  
6) The P48-1 Direct Vent Gas Fireplace is  
approved for alcove installations, which  
meet the clearances listed on this page.  
7) We recommend that you plan your installa-  
tion on paper using exact measurements  
for clearances and floor protection before  
actually installing this appliance. Have an  
authorized inspector, dealer, or installer  
review your plans before installation.  
Note: For vent terminations see page 11.  
6
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
CLEARANCES  
The clearances listed below are Minimum distances unless otherwise stated:  
A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of  
the greatest importance that this fireplace and vent system be installed only in accordance with these instructions.  
Clearance to Combustibles from:  
Caution Requirements  
Back  
Side  
Floor  
0"  
0"  
0"  
(0mm)  
(0mm)  
(0mm)  
The top, back and sides of the fireplace are defined by  
standoffs. The metal ends of the standoff may NOT be  
recessed into combustible construction.  
Minimum Clearance from Top of Front Facing:  
Mantel  
min. 8"  
(203mm)  
Ceiling  
39"  
(990mm) from top of front facing above louvers.  
Side Wall:  
6"  
(152mm)  
Horizontal Vent Clearances:  
Top  
Side  
Bottom  
2-1/2"  
1-1/2"  
1-1/2"  
(64mm)  
(38mm)  
(38mm)  
Vertical Vent Clearances:  
1-1/4"  
(32mm)  
Alcove Clearances:  
Max. Depth 36"  
Min. Width 60"  
Min. Height 80"  
(914mm)  
(1524mm)  
(2032mm)  
WARNING  
Fire hazard is an extreme risk  
if these clearances (air space) to combustible materials  
are not adhered to. It is of greatest importance that this  
fireplace and vent system be installed only in  
accordance with these instructions.  
The HeatWave Duct Kit  
and the Heat Release  
Kit have different clear-  
ance and framin require-  
ments, check the Heat-  
Heat Release Kit  
Wave and Heat Release  
manual for details.  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
INSTALLATION  
MANTELS  
Because of the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from louver are  
shown in the diagram below.  
Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-  
combustible board.  
This drawing is to scale at 1:6 (one inch = 6  
inches)  
Mantel can be installed anywhere in shaded  
area using the above scale for units with the  
Flush Front and with the optional Bay Front.  
Note: Ensure the paint that is used on  
the mantel and the facing is "heat  
resistant" or the paint may discol-  
our.  
MANTEL LEG CLEARANCES  
Combustible mantel leg clearances as per diagram:  
Maximum  
1-1/2" projection at 3"  
minimumclearance.  
8
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
FRAMING & FINISHING  
1) Determine the total thickness of facing material (eg. drywall plus  
ceramic tiles) to allow the finished surface to be flush with the front  
of the unit. Total facing thickness can vary from 1/2" (13mm) to  
1-1/4" (32mm) thick.  
2) Frame in the enclosure for the unit with framing material. The framed  
opening for the assembled kit is 47-1/2" high x 48-1/2" wide x  
26-1/4" deep (1207mm H x 1232mm W x 667mm D). See Diagram 1.  
Diagram 1  
Note: 43" (1092mm) is the minimum height for flex termination  
and Simpson Dura-Vent terminations.  
3) For exterior walls, insulate the enclosure to the same degree as the  
rest of the house, apply vapour barrier and drywall, as per local  
installation codes. (Do not insulate the fireplace itself.)  
4) The unit does not have to be completely enclosed in a chase. The  
clearance on top of the unit from the top standoffs is 0" so  
combustible building materials can be laid directly on top of the  
standoffs. You must maintain clearances from the vent to combus-  
tiblematerials:Seepage7.Combustiblematerialscanbelaidagainst  
the side and back standoffs and the stove base.  
The HeatWave Duct Kit has different  
clearance and framing requirements,  
check the HeatWave manual for details.  
IMPORTANT  
When installing the unit with any vertical venting off the top of the  
unit as shown, the minimum framing depth changes accordingly.  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
INSTALLATION  
Top Facing Support and  
Side Nailing Strips  
"C" Screw Position:  
UNIT ASSEMBLY  
PRIOR TO  
INSTALLATION  
For a facing material depth of 1-1/4"  
(32mm), the top facing support must be  
reversed.  
Determine the total thickness of facing material  
(e.g. drywall plus ceramic tiles) to allow the  
finished surface to be flush with the front of the  
unit. Total facing thickness can vary from 1/2"  
(13mm) to 1-1/4" (32mm) thick.  
TheTopFacingSupport, theSideNailingStrips  
and the 2 Top Standoffs must be correctly  
positioned and attached to the top before unit  
is slipped into position.  
The Top Facing Support & Side Nailing Strips  
can be mounted in 3 different positions depend-  
ing on the thickness of the facing material.  
TopStandoffAssembly  
The top standoffs are shipped in a flat position  
and must be folded into shape and attached.  
Screw  
Position  
Facing Material  
Depth  
1) Remove the standoffs from the fireplace  
top.  
A
B
C*  
1/2" / 13mm  
7/8" / 22mm  
1-1/4" / 32mm  
2) Take each standoff and bend into the cor-  
rect shape. Bend up at the bend lines until  
the screw holes in the standoff and the pre-  
punched screw holes on the fireplace top  
line up.  
2) Use the same screw hole position for the  
Side Nailing Strips as was used for the Top  
Facing Support. Attach each side nailing  
strip using 3 screws.  
* For "C" screw position the top facing support  
is reversed.  
3) Attach the standoff securely to the top with  
2 screws per standoff (on opposite cor-  
ners).  
1) Mount Top Facing Support using the 3  
supplied screws into the three pre-punched  
screw holes on the top front of the unit. Use  
hole positions A, B, or C depending on your  
facing depth.  
VENTING  
INTRODUCTION  
The P48-1 uses the "balanced flue" tech-  
nology Co Axial system. The inner liner vents  
products of combustion to the outside while the  
outer liner draws outside combustion air into  
the combustion chamber thereby eliminating  
the need to use heated room air for combustion  
and losing warm room air up the chimney.  
Note: These flue pipes must not be con-  
nected to any other appliance.  
The gas appliance and vent system must be  
vented directly to the outside of the building,  
and never be attached to a chimney serving a  
separate solid fuel or gas burning appliance.  
Each direct vent gas appliance must use it's  
own separate vent system. Common vent  
systems are prohibited.  
10  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
EXTERIOR VENT TERMINATION REQUIREMENTS  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
INSTALLATION  
VENTING  
Regency Direct Vent System (Flex) Horizontal  
Terminations Only  
These venting systems, in combination with the P48-1 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by  
Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram on page 11.  
Regency Direct Vent (Flex) System Termina-  
tion Kit (Part# 946-615) includes all the parts  
needed to install the P48-1 with a maximum  
run of 4 feet.  
1) 8" dia. flexible liner (4 ft. length)  
2) 5" dia. flexible liner (4 ft. length)  
3) spring spacers (4)  
4) thimble (2)  
5) AstroCap XL termination cap (1)  
6) screws (12)  
7) tube of Mill Pac (1)  
8) plated screws (8)  
9) screws #8 x 1-1/2" Drill Point, Stainless Steel (4)  
10) vinyl siding standoff  
If longer runs are needed, the Regency Direct  
Vent system (Flex) Part# 946-616 includes all  
the parts needed to install the P48-1 with a  
maximum 10' run.  
1) 8" dia. flexible liner (10 ft. length)  
2) 5" dia. flexible liner (10 ft. length)  
3) spring spacers (7)  
4) thimble (2)  
5) AstroCap XL termination cap (1)  
6) screws (12)  
7) tube of Mill Pac (1)  
8) plated screws (8)  
9) screws #8 x 1-1/2" Drill Point, Stainless Steel (4)  
10) vinyl siding standoff  
Notes:  
1) Liner sections should be continuous without any joints or seams.  
2) Only Flex pipe purchased from Regency may be used for Flex installations.  
3) If you are installing the P48-1 into a Regency Mantel Kit, use the minimum horizontal vent height (centre-line of 43"). Remember  
to include the mantel base in your calculations and to maintain the 2-1/2" clearance to the underside of the mantel top.  
12  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
SIMPSON DURA-VENT VENTING  
Horizontal or Vertical Terminations  
The Simpson Dura-Vent Direct Vent System offers a complete line of component parts for installation of both horizontal and vertical installations.  
Many items are offered in decorative black, as well as galvanized finish. We recommend using the galvanized finish for installation with the P48-  
1.  
Flat Wall Installation  
The minimum components required for a basic  
horizontal termination are:  
Wall Thickness  
(inches)  
Vent Length  
Required (inches)  
4" - 5-1/2"  
7" - 8-1/2"  
10" - 11-1/2"  
9" - 14-1/2"  
15" - 23-1/2"  
none  
1
1
1
1
1
Horizontal Termination Cap  
45o Elbow  
Flue Adaptor  
WallThimble  
Length of pipe to suit wall thickness  
(see chart)  
6"  
9"  
12"  
11" - 14-5/8" Adj. Pipe  
Wall thickness is measured from the back  
standoffs to the inside mounting surface of  
termination cap. For siding other than vinyl  
furring strips may be used, instead of the vinyl  
siding standoff, to create a level surface to  
mounttheventterminal. TheTerminalmustnot  
be recessed into siding. Measure the wall  
thickness including furring strips.  
If a Vinyl Siding Standoff is required (it must be  
used with vinyl siding), measure to outside  
surface of wall without siding and add 2  
inches.  
Alternate  
Horizontal Termination  
Caps  
SIMPSON DURA-VENT VENTING  
COMPONENTS LIST  
Part # Description  
Part # Description  
Part # Description  
1281 Snorkel-36" Rise Term.Cap  
1240 Wall Thimble-Suprt/Box  
1241 Cathdrl/Clng-Sprt/Box  
3951 BrassTrimforWallThimble/CeilingSupport  
1263 Firestop Spacer  
1243 Flashing 0/12-6/12  
1243S Flashing 7/12-12/12  
1253 StormCollar  
1208B 6" Pipe Length-Black  
1207B 9" Pipe Length-Black  
1206 12" Pipe Length Galv.  
1206B 12" Pipe Length-Black  
1204 24" Pipe Length Galv.  
1204B 24" Pipe Length-Black  
1203 36" Pipe Length Galv.  
1203B 36" Pipe Length-Black  
1202 48" Pipe Length Galv.  
1202B 48" Pipe Length-Black  
1211B 11"-14 5/8" Adj./P/L-Black  
1217B 17"- 24" Adj. Length Black  
1245  
45O Elbow Galv.  
1245B 45O Elbow-Black  
1245G 45O Elbow-Swivel Galv.  
1245BG 45O Elbow-Swivel-Black  
1290  
90O Elbow Galv.  
1290B 90O Elbow-Black  
1290G 90O Elbow-Swivel Galv.  
1290BG 90O Elbow-Swivel-Black  
1250 Vinyl Siding Standoff  
1288 Wall Strap  
1247 WallThimble  
1291 High Wind Term. Cap (Vertical Only)  
1285 Horiz.Sq.HighWind Trm.Cap (Only)  
1282 Snorkel-14" Rise Term.Cap  
Parts not supplied by Dura-Vent  
770-994 Dura-Vent Flue Adaptor  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
INSTALLATION  
VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS  
SIMPSON DURA-VENT DIRECT VENT GS SYSTEM and  
REGENCY DIRECT VENT SYSTEM (FLEX)  
(Propane & Natural Gas)  
The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 45o and one 90o elbow (two 45o elbows equal  
one 90o elbow).  
Note: Must use optional flue adapter (Part # 770-994) when using Simpson Dura-Vent pipe. (Refer to page 13.)  
Simpson Dura-Vent  
5" inner diameter  
8" outer diameter  
Regency Flex Vent  
5" inner diameter  
8" outer diameter  
A vent guard should be used when-  
ever the termination is lower than the  
specified minimum or as per local  
codes.  
Note: Regency Direct Vent System  
(Flex) is only approved for hor-  
izontal terminations.  
Maintain clearances to combustibles as listed on pages 6 to 9.  
Horizontal vent must be supported every 3 feet.  
Firestops are required at each floor level and whenever passing through a wall.  
14  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
Horizontal Venting with Two (2) 90o Elbows  
Horizontal Venting with Three (3) 90o Elbows  
One 90o elbow = Two 45o elbows.  
One 90o elbow = Two 45o elbows.  
Option  
A)  
V
H + H1  
3' Max.  
Option  
A)  
H
V
H + H1 + H2  
3' Max.  
5' Max.  
6' Max.  
7' Max.  
With these options, maxi-  
mum total pipe length is 30  
feet with minimum of 6 feet  
total vertical and maximum  
8 feet total horizontal.  
Please note minimum 1  
foot between 90o elbows  
is required.  
Withtheseoptions, max.  
total pipe length is 30  
feet with min. of 11 feet  
total vertical and max. 9  
feet total horizontal.  
Please note min.  
1' Min.  
2' Min.  
3' Min.  
4' Min.  
5' Min.  
6' Min.  
1 Max. 1' Min.  
2'Max. 3' Min.  
3'Max. 5' Min.  
4'Max. 7' Min.  
5'Max. 9' Min.  
B)  
C)  
D)  
E)  
4' Max.  
5' Max.  
6' Max.  
7' Max.  
8' Max.  
B)  
C)  
D)  
E)  
1 foot between 90o  
elbows is required.  
8' Max.  
F)  
F)  
6'Max. 11' Min. 9' Max.  
Horizontal Venting with Two (2) 90o Elbows  
One 90o elbow = Two 45o elbows.  
Option  
A)  
H
V
H + H1  
With these options, max.  
total pipe length is 30 feet  
with min. of 8 feet total  
vertical and max. 8 feet  
total horizontal.  
Please note min. 1 foot  
between 90o elbows is  
required.  
1'Max. 1' Min. 3' Max.  
2'Max. 2' Min. 5' Max.  
3'Max. 4' Min. 6' Max.  
4'Max. 6' Min. 7' Max.  
5'Max. 8' Min. 8' Max.  
B)  
C)  
D)  
E)  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  
INSTALLATION  
Horizontal Venting with Three (3) 90o Elbows  
One 90o elbow = Two 45o elbows.  
Option  
A)  
V
H
V + V1  
H + H1  
With these options,  
max. total pipe length  
is 30 feet with min. of  
12 feet total vertical  
and max. 9 feet total  
horizontal.  
Please note min. 1  
foot between 90o  
elbows is required.  
2' Min. 1'Max. 3' Min. 4' Max.  
3' Min. 2'Max. 4' Min. 5' Max.  
4' Min. 3'Max. 6' Min. 6' Max.  
5' Min. 4'Max. 8' Min. 7' Max.  
6' Min. 5Max. 10' Min. 8' Max.  
7' Min. 6'Max. 12' Min. 9' Max.  
B)  
C)  
D)  
E)  
F)  
Vertical Venting with Two (2) 90o Elbows  
Vertical Venting with Two (2) 90o Elbows  
One 90o elbow = Two 45o elbows.  
One 90o elbow = Two 45o elbows.  
Option H + H1  
V
Option  
A)  
V
H
V + V1  
With these options, max. total  
pipe length is 30 feet with min.  
of6feettotalverticalandmax.  
8 feet total horizontal.  
Please note min. 1 foot  
between 90o elbows is re-  
quired.  
Withtheseoptions,max.total  
pipelengthis30feetwithmin.  
of 6 feet total vertical and  
max. 6 feet total horizontal.  
Please note min. 1 foot  
between 90o elbows is re-  
quired.  
A)  
B)  
C)  
D)  
E)  
2' Max. 2' Min.  
3' Max. 3' Min.  
4' Max. 4' Min.  
5' Max. 5' Min.  
6' Max. 6' Min.  
1' Min. 4'Max. 2' Min.  
2' Min. 5'Max. 3' Min.  
3' Min. 6'Max. 4' Min.  
4' Min. 7'Max. 5' Min.  
5' Min. 8'Max. 6' Min.  
B)  
C)  
D)  
E)  
Foradditionalverticalvent-  
ing with 2 x 90o elbows,  
refer to page 18.  
16  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
Vertical Venting with Three (3) 90o Elbows  
One 90o elbow = Two 45o elbows.  
Option  
A)  
H
V
H + H1 V + V1  
With these options, max. total  
pipelengthis30feetwithmin.  
of 11 feet total vertical and  
max. 7 feet total horizontal.  
Please note min. 1 foot  
between 90o elbows is re-  
quired.  
1'Max. 1' Min. 3'Max. 3' Min.  
2'Max. 2' Min. 4'Max. 5' Min.  
3'Max. 3' Min.' 5'Max. 7' Min.  
4'Max. 4' Min. 6'Max. 9' Min.  
5'Max. 5' Min. 7'Max. 11' Min.  
B)  
C)  
D)  
E)  
Vertical Venting with Three (3) 90o Elbows  
One 90o elbow = Two 45o elbows.  
Option  
A)  
V
H + H1 V + V1  
With these options, max. to-  
tal pipe length is 30 feet with  
min. of 10 feet total vertical  
and max. 8 feet total horizon-  
tal.  
Please note min. 1 foot  
between 90o elbows is re-  
quired.  
2' Min. 3'Max. 4' Min.  
3' Min. 4'Max. 6' Min.  
4' Min. 5'Max. 7' Min.  
5' Min. 6'Max. 8' Min.  
6' Min. 7'Max. 9' Min.  
7' Min. 8'Max. 10' Min.  
B)  
C)  
D)  
E)  
F)  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
VENTING ARRANGEMENTS - VERTICAL TERMINATIONS  
SIMPSON DURA-VENT DIRECT VENT GS SYSTEM  
(Propane & Natural Gas)  
The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations , using two 90o elbows,  
with Simpson Dura-Vent Direct Vent GS vent systems for Propane and Natural Gas.  
Vent must be supported at offsets.  
Firestops are required at each floor level and whenever passing through a wall.  
Maintain clearances to combustibles.  
Note: Must use optional flue adapter when using Simpson Dura-Vent pipe (Part # 510-994).  
18  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
The P48-1 is approved for a maximum 40 ft. straight vertical, with Simpson  
Dura-Vent Direct Vent GS vent systems for Propane and Natural Gas, as  
per diagram.  
The shaded area in the diagram shows all allowable combinations of straight  
vertical and offset to vertical terminations with Simpson Dura-Vent Direct  
Vent GS vent systems for Propane and Natural Gas. Maximum two 45o  
elbows allowed.  
Vent must be supported at offsets  
Firestops are required at each floor level and whenever passing  
through a wall.  
Maintain clearances to combustibles as listed on pages 6 to 9.  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
19  
INSTALLATION  
They may be located by examining the  
inside of the female ends.  
HORIZONTAL  
INSTALLATIONS  
Note: Apply sealant "Mill-Pac" to inner  
pipe and high temp silicone seal-  
ant to outer pipe on every twist-  
lock joint.  
Install the vent system according to the manu-  
facturer's instructions included with the com-  
ponents.  
b) Horizontal runs of vent must be sup-  
ported every 3 feet (0.9meter). Wall  
straps are available for this purpose.  
1) Set the unit in its desired location. Check to  
determine if wall studs or roof rafters are  
in the way when the venting system is  
attached. If this is the case, you may want  
to adjust the location of the unit. Rough in  
the gas preferably on the right side of the  
unit and the electrical (junction block is on  
the left side) on the left.  
5) Mark the wall for a 11" x 11" (279mm x  
279mm) square hole. The center of the  
square hole should line up with the center-  
lineofthehorizontalpipe.Cutandframethe  
11inch (279mm)squareholeintheexterior  
wall where the vent will be terminated.  
Diagram 5  
The four wood screws provided should be  
replaced with appropriate fasteners for  
stucco, brick, concrete, or other types of  
sidings.  
2) Direct Vent pipe and fittings are designed  
with special twist-lock connections to con-  
nect the venting system to the appliance  
flue outlet. A twist-lock appliance adaptor  
is an available option that must be used in  
conjunction with the Simpson Dura-Vent  
Direct Vent GS system. Install the adaptor  
after the unit is set in its desired location  
otherwise the unit will not fit through the  
36-5/8" (930mm) high frame opening.  
If the wall being penetrated is constructed  
of non-combustible material, i.e. masonry  
block or concrete, a 8" (203mm) diameter  
hole is acceptable.  
7) Before connecting the horizontal run of  
vent pipe to the vent termination, slide the  
Wall Thimble (Part # 1247) over the vent  
pipe.  
8) Slide the appliance and vent assembly to-  
wards the wall carefully inserting the vent  
pipe into the vent cap assembly. It is impor-  
tant that the vent pipe extends into the vent  
cap sufficient distance so as to result in a  
minimum pipe overlap of 1-1/4 inches  
(32mm). Secure the connection between  
the vent pipe and the vent cap by attaching  
the two sheet metal strips extending from  
the vent cap assembly into the outer wall of  
the vent pipe. Use the two sheet metal  
screws provided to connect the strips to  
the pipe section. See Diagram 6.  
3) Put a bead of silicone inside the outer  
section of the adapter and a bead of Stove  
Mate on the inner collar. Slip the adapter  
over the existing inner and outer flue collar  
and fasten to the outer collar only with the  
3 supplied screws (drilling pilot holes will  
make this easier). Level the fireplace and  
fasten it to the framing using nails or screws  
through the nailing strips.  
4) Assemble the desired combination of pipe  
and elbows to the appliance adaptor and  
twist-lock for a solid connection.  
Diagram 2  
Note:  
Note:  
a) The horizontal run of vent must be level,  
or have a 1/4 inch rise for every 1 foot  
of run towards the termination. Never  
allow the vent to run downward. This  
could cause high temperatures and  
may present the possibility of a fire.  
a) Twist-lock procedure: Four indenta-  
tions, located on the female ends of  
pipes and fittings, are designed to slide  
straight onto the male ends of adjacent  
pipes and fittings, by orienting the four  
pipe indentations so they match and  
slide in to the four entry slots on the  
male ends. (Diagram 1) Push the pipe  
sections completely together, then  
twist-lock one section clockwise ap-  
proximately one-quarter turn, until the  
two sections are fully locked. The fe-  
malelockinglugswillnotbevisiblefrom  
theoutside,ontheBlackPipeorfittings.  
b) The location of the horizontal vent ter-  
mination on an exterior wall must meet  
alllocalandnationalbuildingcodes,and  
must not be blocked or obstructed. For  
External Vent Terminal Locations, see  
diagram on page 11.  
Diagram 6  
9) Install wall thimble in the center of the 11"  
(279mm) square and attach with wood  
screws (Diagram 7).  
6) The arrow on the vent cap should be  
pointing up. Insure that the 1-1/4"(32mm)  
clearances to combustible materials are  
maintained(Diagram5).Installthetermina-  
tion cap.  
Diagram 1  
Note: If installing termination on a siding  
covered wall, a vinyl siding stand-  
off or furring strips must be used  
to ensure that the termination is  
not recessed into the siding.  
Diagram 7  
20  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
4) Assemble the desired lengths of pipe and  
elbows. Ensure that all pipes and elbow  
connections are in the fully twist-locked  
position and sealed.  
VERTICAL  
TERMINATION  
1) Maintain the 1-1/4"(32mm)  
clearances (air spaces) to  
combustibles when pass-  
ing through ceilings, walls,  
roofs, enclosures, attic raft-  
er, or other nearby combusti-  
ble surfaces. Do not pack air  
spaces with insulation.  
Check pages 16-17 for the  
maximum vertical rise of the  
venting system and the maxi-  
mum horizontal offset limita-  
Note:  
Diagram 5  
Apply sealant "Mill-Pac" to inner pipe and  
high temp silicone sealant to outer pipe  
on every twist-lock joint.  
Roof Pitch  
Minimum Vent Height  
Feet  
2
Meters  
0.61  
0.61  
0.61  
0.76  
0.99  
1.22  
1.52  
1.83  
2.13  
2.29  
2.44  
flat to 7/12  
over 7/12 to 8/12  
over 8/12 to 9/12  
over 9/12 to 10/12  
over 10/12 to 11/12  
over 11/12 to 12/12  
over 12/12 to 14/12  
over 14/12 to 16/12  
over 16/12 to 18/12  
over 18/12 to 20/12  
over 20/12 to 21/12  
2
2
tions.  
2.5  
3.25  
4
Diagram 1  
2) Set the gas appliance in its  
desiredlocation.Drop  
5
a plumb bob down  
from the ceiling to the  
position of the appli-  
ance flue exit, and  
mark the location  
where the vent will  
penetrate the ceiling. Drill a small hole at his  
point. Next, drop a plumb bob from the roof  
to the hole previously drilled in the ceiling,  
and mark the spot where the vent will  
penetratetheroof.Determineifceilingjoists,  
roof rafters or other framing will  
obstruct the venting system. You  
may wish to relo-  
6
5) Cut a hole in the roof centered on the small  
drilled hole placed in the roof in Step 2. The  
hole should be of sufficient size to meet the  
minimum requirements for clearance to  
combustibles of 1-1/4"(32mm). Slip the  
flashingundertheshingles(shinglesshould  
overlap half the flashing) as per Diagram 4.  
7
7.5  
8
A poor draft, or down drafting can result from  
high wind conditions near big trees or adjoin-  
ing roof lines, in these cases, increasing the  
vent height may solve the problem.  
7) Ensure vent is vertical and secure the base  
of the flashing to the roof with roofing rails,  
slide storm collar over the pipe section and  
seal with a mastic.  
cate the appliance  
or to offset, as  
shown in Diagram  
2 to avoid cutting  
8) Install the vertical termination cap by twist-  
loadbearingmem-  
locking it.  
bers.  
Note: Any closets or storage spaces,  
which the vent passes through  
must be enclosed.  
Diagram 4: The upper half of the flashing is  
installed under the roofing material and not  
nailed down until the chimney is installed.  
This allows for small adjustments.  
Diagram 2  
OffsetChart  
3) A Firestop spacer must be installed in the  
floor or ceiling of every level. To install the  
Firestop spacer in a flat ceiling or wall, cut  
a 11 inch (279mm) square hole. Frame the  
hole as shown in Diagram 3 and install the  
firestop.  
6) Continue to assemble pipe lengths.  
Note: If an offset is necessary in the attic  
to avoid obstructions, it is impor-  
tant to support the vent pipe every  
3 feet (0.9 meter), to avoid exces-  
sive stress on the elbows, and  
possible separation. Wall straps  
are available for this purpose  
(Diagram 2).  
Galvanized pipe is desirable above the roof-  
line due to its higher corrosion resistance.  
Continue to add pipe sections through the  
flashing until the height of the vent cap meets  
theminimumheightrequirementsspecifiedin  
Diagram 5 or local codes. Note that for steep  
roof pitches, the vertical height must be in-  
creased.  
Diagram 3  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
21  
INSTALLATION  
4) Separate the 2 halves of the wall thimble  
and securely fasten the one with the tabs  
to the outside wall making sure that the tabs  
are on top and bottom. Fasten the other  
thimble half to the inside wall. The thimble  
halves slip inside each other and can be  
adjusted for 2 x 4 or 2 x 6 walls. The liners  
must slip over the collars a minimum  
of 1-3/8".  
IMPORTANT: Do not locate termination  
hood where excessive snow or ice build-  
up may occur. Be sure to check vent  
terminationareaaftersnowfalls, andclear  
to prevent accidental blockage of venting  
system. When using snow blowers, make  
sure snow is not directed towards vent  
termination area.  
INSTALLATION  
PROCEDURES  
for Regency Direct Vent  
System (Flex)  
1) Locate the unit in the framing, rough in the  
gas (preferably on the right side of the unit)  
and the electrical (Junction block is on the  
left side) on the left. Locate the centerline 5) Slip the assembled liner and termination  
of the termination and mark wall according-  
ly. Cuta11"(279mm)holeinthewall(inside  
dimension).  
assembly through the thimble making sure  
the termination cap faces up (there are  
markings on the cap that show which way  
is up). This will position the termination cap  
with proper down slope for draining water.  
Fasten the cap to the outer wall with the 4  
supplied screws.  
ASTROCAPXL  
DIMENSIONS  
Note: A top clearance of 2-1/2"(64mm)  
and side & bottom clearance of  
1-1/2"(38mm) must be maintained  
except that only a 1" (25mm) clear-  
ance is needed at the termination 6) Pull the centre 5"(127mm) liner and outer  
end. We recommend framing a  
11"(279mm) x 11"(279mm) (inside  
dimensions) hole to give struc-  
tural rigidity for mounting the ter-  
mination.  
8"(203mm) liner out enough to slip over the  
flue collars of the fireplace. (You may wish  
to cut the liner shorter to make it more  
workable.) Do not bend liner more than 90o.  
7) Apply Mill Pac over the fireplace inner collar  
and slip the 5"(127mm) liner down over it  
and attach with 3 supplied screws.  
8) Do the same with the 8"(203mm) liner.  
Note: To make the  
installation more  
aesthetically pleas-  
ing, we recom-  
mend framing out a  
square to mount  
the terminal to.  
9) Apply a bead of silicone between the thim-  
ble and termination and around the outer  
edge of the terminal at the wall in order to  
keep the water out.  
Note: If installing termination on a siding  
covered wall, furring strips must  
be used to ensure that the termi-  
nation is not recessed into the  
siding.  
2) Level the fireplace and fasten it to the  
framing using nails or screws through the  
nailing strips.  
3) Assemble the vent assembly by applying  
Mill Pac to the 5"(127mm) inner collar of the  
terminationand slippingthe5"(127mm)liner  
over it at least 1-3/8" (35mm). Fasten with  
the 3 screws (drilling pilot holes will make  
this easier). Apply Mill Pac or high temper-  
aturesiliconetothe8"(203mm)flexpipeand  
slip it over the 8" outer collar of the vent  
terminal at least 1-3/8"(35mm) and fasten  
with the 3 screws.  
NOTE: Horizontal sections must be sup-  
ported at intervals not exceeding 3  
feet (0.9 meter). (Flame picture and  
performance will be affected by  
sags in the liner).  
22  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
The manifold pressure is controlled by a regu-  
lator built into the gas control, and should be  
checked at the pressure test point.  
For USA installations follow local codes and/or  
the current National Fuel Gas Code, ANSI  
Z223.1.  
P48-NG1SystemData  
For 0 to 4500 feet altitude  
Burner Inlet Orifice Sizes: #27  
Note: To properly check gas pressure,  
both inlet and manifold pressures  
should be checked using the valve  
pressure ports on the valve.  
When using copper or flex connectors use only  
approved fittings. Always provide a union so  
that gas lines can be easily disconnected for  
servicing. Flare nuts for copper lines and flex  
connectors are usually considered to meet this  
requirement.  
Max. Input Rating 51,000 Btu/h  
Min. Input Rating 29,000 Btu/h  
Supply Pressure min.5.0" w.c.  
1) Makesurethevalveisinthe"OFF"position.  
Manifold Pressure  
2) Loosen the "IN" and/or "OUT" pressure  
tap(s), turning counterclockwise with a  
1/8" wide flat screwdriver.  
Important: Always check for gas leaks  
with a soap and water solution or gas  
leak detector. Do not use open flame for  
leak testing.  
(High)  
3.8"+/- 0.2"w.c.  
Log Set: Ceramic fibre, 8 per set.  
Vent System: Simpson Dura-Vent Direct  
Vent System, Regency Flex Kit  
3) Attach manometer to "IN" and/or "OUT"  
pressure tap(s) using a 5/16" ID hose.  
PILOT ADJUSTMENT  
4) Light the pilot and turn the valve to "ON"  
P48-LP1 System Data  
position.  
Conversion Kit# 370-969  
5) The pressure check should be carried out  
with the unit burning and the setting should  
be within the limits specified on the safety  
label.  
For 0 to 4500 feet altitude  
Burner Inlet Orifice Sizes: #47  
Max. Input Rating 48,000 Btu/h  
Min. Input Rating 26,000 Btu/h  
6) When finished reading manometer, turn off  
the gas valve, disconnect the hose and  
tighten the screw (clockwise) with a 1/8"  
flat screwdriver. Note: Screw should be  
snug, but do not over tighten.  
Supply Pressure min.12.0" w.c.  
Manifold Pressure  
Periodically check the pilot flames. Cor-  
rect flame pattern has three strong blue  
flames: 1 flowing around the thermopile,  
1 around the thermocouple and 1 flowing  
across the burner (it does not have to be  
touching the burner).  
(High)  
11"+/- 0.2" w.c.  
S.I.T. VALVE DESCRIPTION  
Log Set: Ceramic fibre, 8 per set.  
Vent System: Simpson Dura-Vent Direct  
Vent System, Regency Flex Kit  
1) Gas cock knob  
2) Manual high/low adjustment  
3) Pilot Adjustment  
4) Thermocouple Connection - option  
5) Outlet Pressure Tap  
6) Inlet Pressure Tap  
7) PilotOutlet  
Note: If you have an incorrect flame pat-  
tern, contact your Regency dealer  
for further instructions.  
HIGH ELEVATION  
Incorrect flame pattern will have small,  
probably yellow flames, not coming into  
proper contact with the rear burner or  
thermopile or thermocouple.  
8) Main Gas Outlet  
9) Alternative TC Connection  
Point  
This unit is approved in Canada for altitude 0 to  
4500 ft. (CAN1 2.17-M91).  
GAS LINE  
INSTALLATION  
The gas line can be brought through either the  
right,theleftside orthebottomoftheappliance.  
The gas valve is situated on the bottom of the  
unit.  
The gas line connection may be made of rigid  
pipe, copper pipe or an approved flex connec-  
tor. (If you are using rigid pipe, ensure that the  
valve can be removed for servicing.) Since  
somemunicipalitieshaveadditionallocalcodes  
it is always best to consult with your local  
authorities and the CAN/CGA B149 installation  
code.  
GAS PIPE PRESSURE  
TESTING  
The appliance must be isolated from the gas  
supply piping system by closing its individual  
manual shut-off valve during any pressure  
testing of the gas supply piping system at test  
pressures equal to or less than 1/2 psig. (3.45  
kPa). Disconnect piping from valve at pres-  
sures over 1/2 psig.  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
23  
INSTALLATION  
BRICK PANELS INSTALLATION  
1) Unhook the 2 spring loaded hooks from the bottom of the flush door  
5) Place the top bracket onto the front edge of the top panel (refer to  
and lift the Flush Front off the unit.  
Diagram 5).  
2) Unwrap the brick pattern panels from the protective wrapping.  
Top Bracket  
Note: The logs must not be in the unit.  
a)  
Loosen the two screws from the bottom of the  
baffle plate. Install the bottom clips onto the  
plate (refer to Diagram 1).  
b a f f l e  
Diagram 5  
6) Slide the top panel and bracket assembly carefully onto the baffle  
plate ensuring the panel is centered. Make sure the tabs of the top  
bracket fit into the baffle openings (refer to Diagrams 6 & 7). The  
back of the top brick panel sits on top of the bottom clips.  
Bottom  
Clips  
Tabs  
Diagram 1  
Diagram 6  
3) Insert the back brick panel first by carefully slipping it between the  
back wall of the firebox and the rear log bracket (refer to Diagram  
2).  
Diagram 2  
Diagram 7  
4) Put the side panels in next. Tilt them in towards the middle of the  
firebox and put the bottom front corner in first. Be very careful not  
to scratch them on the firebox hardware. Place them flat up against  
the wall, they should fit snugly against the top of the firebox (refer  
to Diagrams 3 & 4).  
NOTE:  
If the bottom brick panel must be removed: Remove  
the grate, then remove the Burner Tray. See instructions in  
manual.  
IMPORTANT  
Dangerous operating conditions  
may occur if the panels are broken.  
Diagrams 3 & 4  
24  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
LOG SET INSTALLATION  
Read the instructions below carefully and refer to the diagrams.  
If logs are broken do not use the unit until they are replaced.  
Broken logs can interfere with the pilot operation.  
The gas log kit (Part # 370-930) contains the following pieces:  
a) 02-83  
b) 02-84  
c) 02-85  
d) 02-86  
e) 02-87  
f) 02-88  
g) 02-89  
h) 02-90  
i)  
Center Cross Log  
Right Side Cross Log  
Front Left Side Log  
Front Right Side Log  
Left Side End Log  
Rear Log  
Middle Right Side Log  
Right Side End Log  
Embers (Lava)  
902-338  
902-339  
902-340  
902-341  
902-342  
902-343  
902-344  
902-345  
902-154  
902-179  
02-88  
h)  
Vermiculite  
02-90  
4) Place Log 02-85 on the front left side of the burner. Position the right  
end of the log into the pin on the burner and rest the left end of the  
log between the 1st grate post and the front tab.  
02-88  
02-88  
02-85  
02-87  
02-89  
02-86  
02-84  
02-85  
02-83  
Pin  
Tab  
1st Grate Post  
The "02" reference numbers (i.e. 02-83) are molded  
into the rear of each log.  
5) Line up the two holes on the underside of Log 02-86 with the 2 pins  
on the right side of the burner and position into place.  
1) Carefully remove the logs from the box and unwrap them. The logs  
are fragile, handle with care - do not force into position.  
02-88  
2) Sprinkle the vermiculite all over the top of the base brick panel.  
3) Line up the two holes on the underside of Log 02-88 with the 2 pins  
at the rear of the grate and position into place.  
02-86  
02-85  
Pins  
Pins  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
6) Embers should be placed in front of Log 02-85 and Log 02-86.  
8) Line up the hole on the underside of Log 02-84 with the pin on Log  
02-86andpositionthenotchonthebottomofthelogintothelastgrate  
post.  
02-88  
02-84  
02-86  
02-85  
02-86  
02-83  
Embers  
Last Grate Post  
Pin in Log  
CAUTION: DO NOT cover burner ports with embers.  
9) Place Log 02-89 against the notch in Log 02-84. Rest the notch at  
the end of the log against the grate.  
7) Place Log 02-83 onto the pin in Log 02-88 and position the notch on  
the bottom of the log into the 4th grate post.  
02-88  
02-88  
02-83  
02-86  
02-89  
02-85  
02-84  
Rest log onto the pin  
in Log 02-88.  
Rest notch at the end of  
the log against the grate.  
Notch  
02-83  
02-86  
02-85  
4th Grate Post  
Position the notch on the bottom of  
the log into the 4th grate post.  
26  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
10) Place Log 02-90 onto the right side of the grate. Position the cut-out on  
the underside of the log onto the grate bar.  
11) Place Log 02-87 on the middle left side of the burner. Position the  
bottom rear of the log against the rear tab on the left side of the  
grate. Rest the front edge of the log in the notches on Log 02-85.  
02-87  
02-90  
Tab  
Cut-out  
on the underside of  
the log.  
02-85  
02-90  
02-83  
02-88  
02-89  
02-87  
02-84  
02-85  
Position the cut-out onto the  
grate bar.  
Notches  
02-87  
02-90  
02-89  
02-88  
02-85  
02-83  
02-84  
02-86  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
STANDARD  
FLUSH LOUVERS  
FLUSH DOOR  
1) Install the top louver by sliding the two  
bracket clips into the brackets located un-  
derneath the top of the firebox.  
The standard flush door comes with a black  
frame. To install the frame, simply hook the top  
door flange onto the top of the unit and swing  
the door towards the unit, diagram 1.  
2) Install the bottom louver by folding the lou-  
ver down and then sliding the Bottom Lou-  
ver bracket down onto the 2 pins on the  
base of the unit (diagram 1). Secure with 1  
screw as per diagram 2.  
Burner ON/OFF control box attached to  
bottom flush louver.  
Optional Flush Trim  
Attach the round magnets to the back of the top  
trim piece and to the bottom trim piece, then  
attach trim to the top and bottom of Flush door.  
Diagram 1  
Diagram 2  
Diagram 1  
Be careful that the glass gasket does not roll up;  
there must be a gap between the gasket and the  
door lip to ensure that the door sits securely on  
the unit. Diagram 2.  
Note: Top and  
bottom louvers  
are different.  
3) Openthebottomlouver.PulltheBurnerON/  
OFF control box from inside the bottom of  
the fireplace. Using the 2 screws on the  
louver, secure the control box in place.  
Diagram 2  
Use the hook to pull the spring out until you can  
put the hook into the slot on the bottom door  
bracket. Repeat for 2nd and 3rd spring. See  
diagram 3.  
Diagram 3  
NOTE: Springs must always be OVER  
not under the gas line.  
To remove the flush door, reverse the above  
steps.  
Burner ON/OFF  
control box  
Screws on  
louver bracket  
28  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
4) Reconnect the 2 spring hooks securing the  
flush door.  
OPTIONAL BAY DOOR  
BAY LOUVERS  
The Bay louvers MUST be used  
with the Bay glass option.  
1) Install top louver by sliding the two bracket  
clips into the brackets located on top of the  
bay door. See below. The fitted louver  
leaves a small gap between faceplate  
bottom and louver top.  
5) Slide the valve extension knobs onto the  
valve knobs.  
The optional Bay door is an overlay on the  
flush front. The standard flush door and glass  
must remain on the unit.  
1) Unhook the 2 spring loaded hooks from the  
bottom of the flush door.  
Note: If any maintenance etc. must be  
done in the firebox, first remove  
the Bay louvers and door.  
2) Hook the top of the bay door over the flush  
door flange and swing the bottom against  
the bottom flange of the flush door.  
Note: Top and bottom louvers and  
brackets are different.  
Optional Bay Trim  
Attach the supplied magnets each to the back  
ofthetopandbottomtrimpieces,andattachtrim  
to the topand bottomof Bay door. See diagrams  
3 and 4.  
2) Install bottom louver by sliding the two  
bracket clips into the brackets located un-  
derneath the bay door. Install bottom louver  
by sliding the two bracket clips into the  
brackets located underneath the bay door  
and secure with 1 screw on each end.  
Diagram 3  
3) Openthebottomlouver.PulltheBurnerON/  
OFF control box from inside the bottom of  
the fireplace. Using the 2 screws on the  
louver, secure the control box in place.  
3) Secure to the flush door bottom bracket with  
2 screws provided.  
Burner  
ON/OFF  
control  
box  
Screws  
on louver  
bracket  
Diagram 4  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
DOUBLE SCREEN  
DOOR  
OPTIONAL FINISHING TRIM  
NOTE: Remove both the Flush Louvers or Bay Louvers and the Flush Front or Bay Front prior  
to installing the Finishing Trim.  
1) Pull out the top louver.  
1) Install the Finishing Trim sides as shown in the diagram, line up the holes in the side trim with  
the holes in the firebox side.  
2) Secure with 2 screws per side.  
2) Center the screen door and hook over the  
flush door.  
3) Loosen the 3 screws in the top inside edge of the firebox.  
4) Slide the Finishing Trim Top over the Side Trim pieces and fit the bottom bracket slots over the  
screws. Tighten the 3 screws to secure.  
3) Open the screen door(s) and secure the  
screen door to the flush door front with 2  
clips on the bottom left and right side.  
Clip locations  
Clip installed on right side.  
30  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
OPTION 1:  
OPTION 2:  
OPTION 3:  
REMOTE CONTROL  
WALL SWITCH  
WALL THERMOSTAT  
Can be used with Option 1 or 2  
but not both.  
Can be used with Option 2 or 3  
but not both.  
Can be used with Option 1 or 3  
but not both.  
A wall thermostat may be installed if desired,  
connect the wires as per the wiring diagram on  
page 29. Use the table below to determine the  
maximum wire length.  
Use the Regency Remote Control Kit approved  
for this unit. Use of other systems may void your  
warranty.  
1) Run the supplied 15' of wire through the  
back gas inlet opening. Be careful not to  
damage wire.  
The remote control kit comes with a hand held  
transmitter, a receiver and a wall mounting  
plate.  
Note: We recommend a maximum of 15'  
of wire but if you wish to go with a  
longer run, use the Thermostat  
Wire Table.  
Note: Preferable if the thermostat is in-  
stalled on an interior wall.  
Regencyoffersanoptionalprogrammablether-  
mostat but any 250-750 millivolt rated non-  
anticipator type thermostat that is CSA, ULC or  
UL approved may be used.  
1) Choose a convenient location on the wall to  
install the receiver and the receptacle box  
(protection from extreme heat is very im-  
portant). Run wires from the fireplace to  
that location. Use the Thermostat Wire Ta-  
ble.  
2) Connect the wire to the supplied wall switch  
and install into the receptacle box.  
CAUTION  
Do not connect millivolt  
wall switch wire to a 120V wire.  
CAUTION  
Do not connect millivolt  
wall thermostat wires  
to a 120V wire.  
2) Connect the two wires to the gas valve.  
See diagram.  
Thermostat Wire Table  
Recommended Maximum Lead Length  
(Two-Wire) When Using Wall  
Thermostat (CP-2 System)  
Wire Size  
Max. Length  
14 GA.  
16 GA.  
18 GA.  
20 GA.  
22 GA.  
50 Ft.  
32 Ft.  
20 Ft.  
12 Ft.  
9 Ft.  
CAUTION  
Do not connect millivolt remote  
control wires to a 120V wire.  
3) Install 3 AAA alkaline batteries in transmitter  
and 4 AA alkaline batteries in the receiver.  
Install the receiver and its cover in the wall.  
Switch the remote receiver to "remote"  
mode. The remote control is now ready for  
operation.  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
31  
INSTALLATION  
WIRING DIAGRAM  
No electrical power supply is required for the  
gas control to operate. 120 Volt AC power is  
needed for the fan switch and blower. The fan  
can be hard wired if desired. A terminal block  
is provided on the left hand side of the unit. A  
three wire power cord can also be used and  
plugged into a suitable receptacle.  
NOTE: Even if the fan is not purchased with the  
unit, itisstillagoodideatohardwiretheterminal  
block in case the fan is installed at a later date.  
(Do not cut the ground terminal off under  
any circumstances.)  
** However DO NOT leave this connection  
live until the fan is installed.**  
Fan  
Ground  
Nut  
Star washer  
#8 Ground Lug  
(for mobile home)  
Neutral  
Live  
Green  
OFF  
Ground  
ON  
120V AC  
60 Hz  
Black  
Red  
Red  
Pilot  
Assembly  
Lockwasher  
Fan Thermodisc  
(normally open)  
Rotary Speed  
Control  
Fan  
ground wire  
Piezo  
Ignitor  
White  
(To THTP)  
(To TH)  
ON  
Burner  
OFF  
Thermostat  
Brown  
White  
F
Gas  
In  
Red  
Black  
To Thermocouple IN  
"S.I.T" Valve  
T-Stat  
ON OFF  
Remote Receiver  
or Thermostat  
(Millivolt) (Optional)  
Remote Transmitter  
(Optional)  
Caution: Ensure that the wires do  
not touch any hot surfaces and are  
away from sharp edges.  
CAUTION: Label all wires  
prior to disconnection  
when servicing controls.  
Wiring errors can cause  
improper and dangerous  
operation.  
32  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
INSTALLING THE OPTIONAL FAN  
120 Volt AC power is needed for the fan switch  
and blower. The fan can be hard wired if  
desired. The receptacle box should be installed  
on the left hand side of the unit by a qualified  
electrician. The neutral (wider) slot of the po-  
larized receptacle should be at the top.  
9) Attach the two control boxes to the bottom  
louver and tighten the 2 screws on the left  
side and 2 screws on the right side.  
Unit must be grounded at all times. Do not  
cut the ground terminal off under any  
circumstances.  
1) Shut the power off.  
2) Remove the standard flush door and the  
optional bay door, if installed. Open the  
bottom louver door.  
Diagram 1  
3) Remove the 2 screws holding the Burner  
ON/OFF switch and bracket to the bottom  
louver and lift the assembly out.  
Secure left side with 2 screws.  
Secure right side with 2 screws.  
Diagram 2  
4) Turn the fan base on its side (with the base  
facing towards you) and then slide the fan  
in towards the rear of the unit. Turn the fan  
upright and slip it over the two mounting  
studs. Take care not to damage the insula-  
tion on the fan base. Ensure that the fan  
blades do not rub against the valve  
tubing. Diagram 1.  
10) Secure the fan wires and power cord by  
attaching one of the adhesive backed wire  
holder clips (Part #910-199) onto the stove  
base. Use the second clip to bundle up the  
wires approximately 4" from the control  
box. Ensure that there is no interference  
with the wires when the louver is closed  
and that no wire will touch the hot metal  
surfaces or sharp edges.  
5) Connect fan ground cable to ground lug.  
Refer to wiring diagram.  
11) Plug the fan power cord into the rear end of  
the receptacle box to provide the maximum  
clearance from the louvers.  
6) Slide the thermodisc/cover assembly into  
the bracket clip on the underside of the  
firebox. Check that no wire will touch the hot  
surfaces. Diagram 2.  
Diagram 3: Use the clip & hook on the side  
of the control boxes to join them together.  
To Remove the Fan  
1) Shut the power off.  
8) Secure the two boxes together with one  
7) AttachtheFancontrolboxtothe BurnerON/  
screw.  
OFF control box. Diagram 3.  
2) Reverse the above instructions.  
NOTE: The bearings are lubricated for life.  
Do not lubricate them. Make sure you  
vacuum the fan area on a regular basis.  
IMPORTANT:  
These fans collect a lot of dust from  
within your home. Ensure you maintain  
these fan motors on a regular basis by  
vacuuming out the fan blades and hous-  
ing using a soft brush nozzle.  
Secure the 2 boxes together  
with one screw.  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
33  
INSTALLATION  
CONVERSION KIT FROM NATURAL GAS TO PROPANE MODEL #370-969  
FOR P48-1 USING SIT 820 NOVA GAS VALVE  
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER  
IF IN DOUBT DO NOT DO THIS CONVERSION !!  
Conversion Kit Contains:  
5) Pull off the pilot  
cap to expose the  
pilot orifice.  
Qty. Part # Description  
1
910-018 SIT Conversion Kit-50%  
Turndown LP  
1
1
1
1
1
910-037 LP Injector (Pilot Orifice)  
904-434 Burner Orifice #47  
908-255 Decal "Converted to Propane"  
908-529 5/32" Allen Key  
6) Unscrew the pilot orifice with the allen key  
and replace with the LP pilot orifice in the kit  
and replace pilot cap.  
918-032 Instruction Sheet  
1) Removethelouversandtrimkit.Removethe  
front door.  
2) Remove the logs, embers.  
3) Remove the grate by lifting straight up.  
7) Remove burner orifice with a 1/2" wrench  
and discard. Use another wrench to hold  
on to the elbow behind the orifice.  
4) Remove the burner assembly by removing  
the 1 Phillips head screw and then slide the  
burner assembly away from the orifice and  
lift out.  
Burner Orifice  
8) ReinstallnewburnerorificeLPstamped#47  
and tighten.  
9) Remove and discard the 3 pressure regu-  
lator mounting screws (A), pressure regu-  
lator tower (B) and diaphragm (C).  
10) Insure that the rubber gasket (D) is properly  
positioned and install the new HI/LO pres-  
sure regulator assembly to the valve using  
the new screws (E) supplied with the kit.  
Tighten screws securely.  
Diagram 1: Remove the left screw and then  
slide the burner assembly away from the  
orifice and lift out.  
11) Reverse steps 4) to 1).  
14) Check for gas leaks.  
12) Attach clear label "This unit has been con-  
verted to Propane" near or on the serial #  
decal. Attach white label "This valve has  
been converted from NG to LPG using SIT  
conversion Kit Code 0.907.202" onto the  
valve.  
15) Check inlet and outlet pressures.  
16) Check operation of flame control.  
17) Check for proper flame appearance and  
glow on logs.  
13) Replace yellow "Natural Gas" label with red  
"Propane" label  
34  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
3) Turn gas control knob counterclockwise  
During the first few fires, a white film  
may develop on the glass front as part of  
the curing process. The glass should be  
cleaned after the unit has cooled down  
or the film will bake on and become very  
difficult to remove. Use a non-abrasive  
cleaner and DO NOT ATTEMPT TO CLEAN  
THE GLASS WHILE IT IS HOT.  
OPERATING  
so indicator points to the "PILOT" position.  
Depress the gas control knob fully. De-  
press the igniter button several times until  
the pilot lights. After approximately one  
minute, release the gas control knob. The  
pilot flame should continue to burn. If the  
pilot does not remain lit, repeat operation  
allowing a longer period before releasing  
gas control knob.  
INSTRUCTIONS  
1) Read and understand these instructions  
before operating this appliance.  
2) Check to see that all wiring is correct and  
enclosed to prevent possible shock.  
3) Check to ensure there are no gas leaks.  
4) When the pilot stays lit, turn the gas knob  
further counterclockwise to the "ON" po-  
sition.  
AERATION  
ADJUSTMENT  
4) Make sure the glass in the door frame is  
properly positioned. Never operate the ap-  
pliance with the glass removed.  
5) Use the wall switch, thermostat or remote  
control to turn on the unit.  
The air shutter can be adjusted by moving the  
adjusting wire up or down. The wire is ac-  
cessed through the bottom louver opening.  
Open the air shutter for a blue flame or close for  
a more yellow flame. The burner aeration is  
factory set but may need adjusting due to either  
the local gas supply or altitude.  
5) Verify that the venting and cap are unob-  
structed.  
6) Rotate the flame height regulator to adjust  
the flame height higher or lower.  
6) Ensure that the brick panels are installed.  
7) Verify log placement. If the pilot cannot be  
seen when lighting the unit, the logs have  
been incorrectly positioned.  
SHUTDOWN  
PROCEDURE  
Minimum Air Shutter Opening:  
3/16"  
Fully Open  
Natural Gas  
Propane  
8) The unit should never be turned off, and on  
again without a minimum of a 60 second  
wait.  
1) Use the wall switch, thermostat or remote  
control to turn off the main burner.  
2) Turn the main gas control clockwise to the  
CAUTION: Carbon will be produced if air  
shutter is closed too much.  
"OFF" position to turn off the pilot.  
3) Turn off all electric power to appliance if  
Note: Any damage due to carboning re-  
sulting from improperly setting the  
aeration controls is NOT covered  
under warranty.  
service is to be performed.  
FIRST FIRE  
DO NOT BURN THE APPLIANCE  
WITHOUT THE GLASS FRONT IN  
PLACE.  
LIGHTING  
PROCEDURE  
The first fire in your stove is part of the paint  
curing process. To ensure that the paint is  
properly cured, it is recommended that you  
burn your fireplace for at least four (4) hours  
the first time before you use it with the fan on.  
IMPORTANT  
To ignite or reignite the pilot,  
you must first release the  
tension springs below the door.  
When first operated, the unit will release an  
odour caused by the curing of the paint, the  
burning off of any oils remaining from manu-  
facturing. Smoke detectors in the house may  
go off at this time. Open a few windows to  
ventilate the room for a couple of hours.  
Adjustment Wire - Pull down to open or  
push up to close aeration cap.  
Only when the pilot holds, without pressure  
being applied to the control knob, reapply the  
tension springs to the door. The unit must  
not be operated with the tension springs  
unattached.  
Closed - Tall yellow  
Open - Short Blue  
Note: When the glass is cold and the  
appliance is lit, it may cause con-  
densation and fog the glass. This  
condensation is normal and will  
disappear in a few minutes as the  
glass heats up.  
Note: Aeration Adjustment should only  
be performed by an authorized  
Regency Installer at the time of  
installation or service.  
IMPORTANT Gas cock knob cannot be  
turned from "PILOT" to "OFF" unless it is  
partially depressed.  
1) Turn burner OFF using "ON/OFF" switch.  
2) Turn gas control knob so indicator points to  
"OFF" position and allow 5 minutes for any  
gas in the combustion chamber to escape.  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
35  
OPERATING INSTRUCTIONS  
Copy of the Lighting Plate Instructions  
NORMAL OPERATING  
SOUNDS OF  
GAS APPLIANCES  
It is possible that you will hear some sounds  
from your gas appliance. This is perfectly  
normal due to the fact that there are various  
gauges and types of steel used within your  
appliance. Listedbelowaresomeexamples. All  
are normal operating sounds and should  
not be considered as defects in your appliance.  
Blower:  
Regency gas appliances use high tech blow-  
ers to push heated air farther into the room. It  
is not unusual for the fan to make a "whirring"  
sound when ON. This sound will increase or  
decrease in volume depending on the speed  
setting of your fan speed control.  
Burner Tray:  
The burner tray is positioned directly under the  
burner tube and logs and is made of a different  
gauge material from the rest of the firebox and  
body. Therefore, the varying thicknesses of  
steel will expand and contract at slightly differ-  
ent rates which can cause "ticking" and "crack-  
ing" sounds. You should also be aware that as  
there are temperature changes within the unit  
these sounds will likely re-occur. Again, this is  
normal for steel fireboxes.  
Blower Thermodisc:  
When this thermally activated switch turns ON  
it will create a small "clicking" sound. This is the  
switch contacts closing and is normal.  
Pilot Flame:  
While the pilot flame is on it can make a very  
slight "whisper" sound.  
Gas Control Valve:  
As the gas control valve turns ON and OFF, a  
dullclickingsoundmaybeaudible,thisisnormal  
operation of a gas regulator or valve.  
Unit Body/Firebox:  
Different types and thicknesses of steel will  
expand and contract at different rates resulting  
in some "cracking" and "ticking" sounds will be  
heard throughout the cycling process.  
36  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
7) Drop the thermocouple or thermopile down  
through the extrusion and pull it out of the  
unit.  
2) Remove the Cap, and shine a flashlight  
down the Vent. Remove any bird nests, or  
other foreign material.  
MAINTENANCE  
INSTRUCTIONS  
8) Reinstall the new ones in reverse order.  
3) Check for evidences of excessive con-  
densation, such as water droplets forming  
intheinnerliner,andsubsequentlydripping  
out the joints, Continuous condensation  
can cause corrosion of caps, pipe, and  
fittings. It may be caused by having exces-  
sive lateral runs, too many elbows, and  
exterior portions of the system being ex-  
posed to cold weather.  
1) Always turn off the gas valve before  
cleaning. For relighting, refer to lighting  
instructions. Keep the burner and control  
compartment clean by brushing and vacu-  
uming at least once a year. When cleaning  
the logs, use a soft clean paint brush as the  
logs are fragile and easily damaged.  
GLASS GASKET  
If the glass gasket requires replacement use  
a tadpole glass gasket (Part # 936-155).  
2) Cleanapplianceanddoorwithadampcloth  
(never when unit is hot). Never use an  
abrasive cleaner. The glass should be  
cleaned with a gas fireplace glass cleaner.  
The glass should be cleaned when it  
starts looking cloudy.  
4) Inspect joints, to verify that no pipe sections  
or fittings have been disturbed, and conse-  
quently loosened. Also check mechanical  
supports such as Wall Straps, or plumbers'  
tape for rigidity.  
GOLD-PLATED  
LOUVERS  
3) The heater is finished in a heat resistant  
paint and should only be refinished with  
heat resistant paint. Regency uses Stove-  
Bright Paint - Metallic Black #6309.  
The 24 carat gold-plated finish on the louvers  
and trim requires little maintenance, and need  
only be cleaned with a damp cloth.  
LOG REPLACEMENT  
DO NOT use abrasive materials or chemical  
cleaners, as they may harm the finish and void  
the warranty.  
4) Make a periodic check of burner for proper  
position and condition. Visually check the  
flame of the burner periodically, making  
sure the flames are steady; not lifting or  
floating. Ifthereisaproblem, callaqualified  
service person.  
Theunitshouldneverbeusedwithbrokenlogs.  
Turn off the gas valve and allow the unit to cool  
before opening door and carefully remove the  
logs. (The pilot light generates enough heat to  
burn someone.) If for any reason a log should  
need replacement, you must use the proper  
replacement log. The position of these logs  
must be as shown in the diagrams under Log  
Installation.  
Clean any fingerprints off before turning  
the unit on.  
5) The appliance and venting system must be  
inspected before use, and at least annual-  
ly, by a qualified field service person, to  
ensure that the flow of combustion and  
ventilation air is not obstructed.  
Note: Improper positioning of logs may  
create carbon build-up and will  
severely alter the unit's perform-  
ance which is not covered under  
warranty.  
Note: Never operate the appliance with-  
out the glass properly secured in  
place.  
6) Do not use this appliance if any part has  
been under water. Immediately call a qual-  
ified service technician to inspect the ap-  
pliance and to replace nay part of the  
control system and any gas control which  
has been under water.  
THERMOPILE/  
THERMOCOUPLE  
1) OpentheBottomLouversorGrills.Remove  
7) In the event this appliance has been serv-  
iced check that the vent-air system has  
been properly resealed & reinstalled in  
accordance with the manufacturer's in-  
structions.  
the Top Louver or Grill.  
2) Open and remove door.  
3) Remove log set and embers.  
4) Remove grate and burner.  
8) Verify operation after servicing.  
General Vent Maintenance  
5) Disconnect thermocouple by loosening nut  
from the valve with a 9mm wrench. Discon-  
nect thermopile by loosening 2 screws  
marked TP on the valve.  
Conduct an inspection of the venting system  
semiannually. Recommended areas to inspect  
as follows:  
6) Remove 2 screws from the pilot assembly  
and pull up far enough to be able to loosen  
thethermocoupleorthermopilewitha7/16"  
wrench. NOTE: the pilot line is very fragile,  
use caution when pulling it up.  
1) Check the Venting System for corrosion in  
areas that are exposed to the elements.  
These will appear as rust spots or streaks,  
and in extreme cases, holes. These com-  
ponents should be replaced immediately.  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
37  
MAINTENANCE  
Bay Glass Replacement  
INSTALLING VALVE  
DOOR GLASS  
1) Remove the door from the unit and place on  
Your Regency fireplace is supplied with high  
temperature 5mm-Ceramic glass. If your glass  
requires cleaning, we recommend using an  
approved glass cleaner available at all author-  
ized dealers. Do not use abrasive materials.  
1) Attach the valve to the valve bracket with  
a soft surface to prevent scratching.  
the 4 (m5x8 metric) screws provided.  
2) Remove the nuts holding the glass clips in  
2) Reconnect the "gas out" flare fitting with an  
place and remove.  
11/16" wrench.  
3) Replace the glass. The glass must have  
CAUTION&WARNINGS:  
3) Reconnect the "gas out" flare nut with a 13/  
gasketing around it.  
16" wrench.  
* Do not clean when the glass is hot.  
* Theuseofsubstituteglasswillvoidallproduct  
warranties.  
* Care must be taken to avoid breakage of the  
glass.  
4) Install piezo ignitor push button assembly  
and reconnect wire.  
5) Reconnectthequickdropoutthermocouple  
* Do not strike or abuse the glass.  
* Do not operate this fireplace without the glass  
front or with a cracked or broken glass front.  
* Wear gloves when removing damaged or  
broken glass.  
nut with a 9mm wrench.  
6) Reconnect the pilot tube nut with a 7/16"  
wrench.  
* Replacement of the glass panel(s) should be  
done by a licensed or qualified service per  
son.  
7) Scrape off the old gasket from the floor of  
the firebox and from the valve tray assem-  
bly.  
8) Install a new gasket and reinstall the valve  
GLASSREPLACEMENT  
tray assembly.  
Note: Failure to install a new gasket  
may severely affect the appliance  
performance.  
In the event that you break your glass by impact,  
purchase your replacement from an authorized  
Regency dealer only.  
9) Reinstall the 10 hold down screws.  
Replacement glass is shipped already installed  
into the door frame. Reinstall as per Glass Door  
Installation on page 28.  
10) Hook up the 2 TP and 2 TH wires to the  
appropriate connections on the valve.  
11) Reinstall the two bottom deflectors and  
CAUTION: Wear gloves when re-  
moving damaged or broken glass.  
brick panels.  
4) Reverse the previous steps, replace the  
glass clips and fasten with the nuts but do  
not over tighten, as this can break the glass.  
12) Install burner and grate assembly.  
13) Hookupthegaslineandcheckforgasleaks  
with a soap and water solution or a gas leak  
detector. (Do not use open flame for leak  
testing.)  
WARNING: Do not operate the  
appliance with the glass panels  
removed, cracked or broken. Re-  
placement of the glass panels  
should be done by a licensed or  
qualified service person.  
5) Replace door on the stove and check the  
seal.  
14) Fire up the unit temporarily.  
15) Check the manifold pressure.  
16) Reinstall the logs and brick panels as need-  
ed.  
17) Close the door and replace the louvers.  
18) Fire up the unit again and check for proper  
flame appearance and glow on logs.  
38  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
7) Remove the right and left side deflectors by  
REMOVING VALVE  
removing the 2 screws on each deflector.  
1) Shut off the gas supply.  
2) Remove the louvers (and bay door if it has  
been installed).  
3) Open the flush door and remove the door.  
4) Remove the logs and side brick panels, if  
installed.  
Lift entire valve tray  
assembly out.  
5) Remove the grate by lifting up and out.  
11) Disconnect the 2 TP wires and the 2 TH  
wires from the valve.  
Right Side  
Deflector  
12) Undo the pilot tube from the valve with a 7/  
16" wrench.  
13) Undo the quick drop out thermocouple nut  
on the valve with a 9mm (metric) wrench.  
14) Remove the Piezo igniter wire and push  
Grate  
button assembly.  
6) Remove the burner by removing the screw  
on the left side and then slide the burner to  
the left and lift out.  
Left Side  
Deflector  
8) Remove the base brick panels.  
9) Disconnect the inlet gas line.  
Thermopile Thermocouple  
Wire Wire  
Pilot Nut  
10) Remove the 10 Phillips head screws secur-  
ing the valve tray assembly in place and  
then lift the entire assembly out.  
15) Undo the "gas out" flare nut with a 13/16"  
wrench.  
Remove the screw on the left  
side of the burner.  
16) Undo the "gas out" flare fitting with an 11/  
16" wrench.  
17) Removethe4Phillipsheadscrewsfromthe  
sides of the valve bracket and remove  
valve.  
Hint: If you are using black pipe, ensure  
that there is a union by the valve,  
otherwise removal will be almost  
impossible.  
Slide the burner to the left and lift out.  
Valve Tray  
Assembly  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
39  
PARTS LIST  
P48-1 MAIN ASSEMBLY  
Part #  
Description  
Part #  
Description  
1) 948-259 Door Handle  
3) 948-046 Chain  
4) 948-115 Spring  
51) 902-331 Brick Panel - Base Center  
52) 902-332 Brick Panel - Base Left  
53) 902-333 Brick Panel - Base Right  
6) 430-129 Receptacle Box Mount  
7) 910-429 Box - Receptacle  
8) 910-428 Duplex Receptacle  
9) 910-430 Cover - Receptacle  
10) 904-687 Clamp Connector  
370-928 Brick Panel Set - Standard  
54) 902-334 Brick Panel - Back  
55) 902-335 Brick Panel - Left  
56) 902-336 Brick Panel - Right  
57) 902-582 Brick Panel - Top  
20) 370-037 Top Nailing Strip  
21) 370-038 Side Nailing Strip  
370-945 Herringbone Brick Panel Set  
902-364 Herringbone Brick Panel - Back  
902-365 Herringbone Brick Panel - Left  
902-366 Herringbone Brick Panel - Right  
902-583 Heringbone Brick Panel - Top  
22) 370-015 Baffle Plate  
23) 780-011 Standoff - Top  
24) 780-013 Standoff - Side/Back  
370-901 Brick Panel Set - Standard Brown  
370-902 Brick Panel Set - Standard Red  
370-903 Brick Panel Set - Herringbone Brown  
370-904 Brick Panel Set - Herringbone Red  
27) *  
28) *  
29) *  
30) *  
Outer Flue Collar  
Inner Flue Collar Assy  
FlueMountingPlate  
Gasket for Flue Collar  
946-556 Optional Heat Wave Duct Kit  
89) 946-004 Junction Box  
35) *  
Thermodisc Bracket  
90) 946-000 Round Duct Adaptor  
91) 946-002 Round to Oval Adaptor  
92) 946-001 Oval Duct Adaptor  
93) 946-007 Angle Bracket  
38) 910-241 Switch - Burner ON/OFF(3-way)  
910-899 Wire Harness-Valve to Burner  
432-917 Fan & Speed Control Assy (120 Volts) Optional  
94) 946-517/P Fan Assembly - HeatWave Option  
95) 946-006 Grill Plate - White  
42) 910-331/P Fan Motor  
96) 946-005/01 Wall Adaptor Plate - White  
97) 910-417 Knob - White  
432-966 Fan Switch Assy (120 Volts) Optional  
98) 910-366 Switch Cover Plate - White  
99) 910-412 Fan Speed Controller  
43) 910-813 Power Cord (120 Volts)  
46) 910-330 Fan Speed Control Switch  
47) 904-586 Knob - Speed Control  
48) 910-199 Wire Holder Clip  
49) 910-142 Thermodisc - Fan (Auto ON/OFF)  
910-845 Wire Harness - Plug In Fan  
100) 910-367 Box - Plastic Switch Receptacle  
101) 690-022 Cover Plate - Outer Box Side  
102) 946-010 Flexible Air Duct  
946-011 Insulation 6" dia. x 24"  
50) 770-994 Optional Dura-Vent Adaptor  
946-570 Heat Release Duct Kit (Optional)  
105) 910-165 Fan (120 Volts)  
106) 946-000 Flexible Air Release Duct  
370-969 Conversion Kit - NG to LP  
918-458 Manual  
*Not available as a replacement part.  
40  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS LIST  
30  
28  
89  
50  
93  
94  
30  
20  
29  
93  
27  
21  
23  
92  
91  
22  
96  
95  
23  
102  
100  
99  
24  
21  
97  
98  
90  
HEAT WAVE DUCT KIT  
DOORS & LOUVERS PLEASE  
REFER SEPARATE SECTION  
10  
101  
6
7
8
4
35  
3
9
55  
57  
1
24  
42  
54  
106  
56  
49  
48  
38  
43  
47  
105  
46  
52  
51  
HEAT RELEASE DUCT KIT  
53  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
41  
PARTS LIST  
P48-1 BURNER & LOG ASSEMBLY  
Part #  
Description  
370-574/P  
370-576/P  
*
Valve Assembly - Natural Gas  
Valve Assembly - Propane  
Gasket - Valve Access Plate  
52)  
56) 910-190  
57) 910-378  
910-380  
Piezo Ignitor & Nut  
Valve S.I.T. - Natural Gas  
Valve S.I.T. - Propane  
66) 910-038  
910-039  
Pilot Assy - S.I.T. - 3 Flame NG  
Pilot Assy - S.I.T. - 3 Flame LP  
PilotHolder  
67)  
*
68) W840470  
69) 904-662  
904-434  
Pilot Assembly Gasket  
#27 Orifice - N.G.  
#47 Orifice - Propane  
Orifice Gasket  
936-170  
75)  
*
Valve Access Plate  
Burner Assembly  
Burner/Grate Assembly  
79) 370-535  
82) 370-019  
90) 910-421  
91) 910-422  
Pilot ON/OFF Extension Knob (with Bay Front)  
HI/LOW Extension Knob (with Bay Front)  
370-930  
93) 902-338  
94) 902-339  
95) 902-340  
96) 902-341  
97) 902-342  
98) 902-343  
100) 902-344  
101) 902-345  
P48-1 Log Set  
Center Cross Log  
Right Side Cross Log  
Front Left Side Log  
Front Right Side Log  
Left Side End Log  
Rear Log  
Middle Right Side Log  
Right Side End Log  
*Not available as a replacement part.  
42  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS LIST  
P48-1 FLUSH DOOR & LOUVERS  
Part #  
Description  
Part #  
Description  
370-925  
370-924  
370-926  
Flush Louvers (Set) - Steel/Black  
Flush Louvers (Set) - Black  
Flush Louvers (Set) - Gold/Black  
Flush Louver Assembly - Top  
Flush Louver Assembly - Bottom  
150) *  
Flush Glass Trim  
370-920  
370-922  
904-196  
Flush Glass Trim (Set) - Steel  
Flush Glass Trim (Set) - Gold  
Magnet  
133) *  
134) *  
370-933  
171) *  
172) *  
174) 511-085  
178) 948-257  
180) 512-546  
Double Screen Door (Complete)  
Door Frame Assembly - Left  
Door Frame Assembly - Right  
Handle  
Lift Hinge on Door  
Door Latch Assembly  
370-518/P  
135) 940-335/P  
138) *  
Flush Door Assembly Complete  
Glass (Flush)  
Flush Door Frame  
139) 936-155  
Glass Gasket (Tadpole)  
140) 948-042  
Spring Hinge  
188) 948-216  
Regency Logo Plate  
370-944  
370-946  
141) *  
Finishing Trim - Black  
Finishing Trim - Steel  
Trim Side Left  
*Not available as a replacement part.  
142) *  
143) *  
TrimSideRight  
TrimTop  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
43  
PARTS LIST  
P48-1 BAY FRONT & LOUVERS  
Part #  
Description  
Bay Front Complete with Glass & Black Trim  
Bay Front Screen & Black Trim  
370-931  
370-932  
106) 940-337/P  
107) 936-243  
108) 940-336/P  
111) 902-362  
112) 902-363  
370-905  
Side Glass  
Glass Gasket  
Center Glass  
Brick Panel - Left Side Bay  
Brick Panel - Right Side Bay  
Bay Brick Panel Set - Standard Brown  
Bay Brick Panel Set - Standard Red  
370-906  
113) 370-086  
370-936  
Bay Door Trim (Each) -Black  
Bay Door Trim (Set) - Gold  
Bay Door Trim (Set) - Steel  
370-934  
370-938  
370-942  
370-940  
Bay Louvers (Set) - Black  
Bay Louvers (Set) - Gold/Black  
Bay Louvers (Set) - Steel/Black  
Bay Louver Assembly - Top  
Bay Louver Assembly - Bottom  
Magnet (1" round)  
115) *  
116) *  
117) 904-196  
119) 370-093  
120) 400-189  
Bay Door Baffle  
Flush Glass Retainer Bracket  
122) 948-216  
Regency Logo Plate  
*Not available as a replacement part.  
44  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
_____________________________________________________________________________________  
____________________________________________________________  
__________________________________________________________  
____________________________________________________________  
_______________________________________________________  
_____________________________________________________  
__________________________________________________________  
_________________________________________________________  
_________________________________________________________  
______________________________________________________  
______________________________________________________  
_______________________________________________________________  
___________________________________________________________  
__________________________________________________________  
____________________________________________________________  
____________________________________________________________  
____________________________________________________________  
_____________________________________________________________  
__________________________________________________________  
__________________________________________________________  
_____________________________________________________  
________________________________________________________  
_________________________________________________________  
_________________________________________________________  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
45  
NOTES  
_____________________________________________________________________________________  
____________________________________________________________  
__________________________________________________________  
____________________________________________________________  
_______________________________________________________  
_____________________________________________________  
__________________________________________________________  
_________________________________________________________  
_________________________________________________________  
______________________________________________________  
______________________________________________________  
_______________________________________________________________  
___________________________________________________________  
__________________________________________________________  
____________________________________________________________  
____________________________________________________________  
____________________________________________________________  
_____________________________________________________________  
__________________________________________________________  
__________________________________________________________  
_____________________________________________________  
________________________________________________________  
_________________________________________________________  
_________________________________________________________  
46  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY  
Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each  
unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original  
purchaser of a Regency Product. This warranty is not transferable.  
The Warranty: Limited Lifetime  
The combustion chamber, heat exchanger, burner tubes/pans, logs, brick panels and gold plating (against defective manufacture only) are covered under the Limited  
Lifetime Warranty for five (5) years for parts and subsidized labour* and parts only thereafter.  
Glass is covered for lifetime against thermal breakage only, parts and subsidized labour* for five (5) years and parts only thereafter from date of purchase.  
External casting, surrounds and grills are covered against cracks and warps resulting from manufacturer defects, parts and subsidized labour* for three (3) years from  
the date of purchase and parts only thereafter.  
Special Finishes - One year on brushed nickel and antique copper full screens and doors. You can expect some changes in color as the product "ages" with constant  
heating and cooling. FPI warranties the product for any manufacturing defects on the original product. However, the manufacturers warranty does not cover changing  
colors and marks, ie. finger prints, etc applied after the purchase of the product. Damage from the use of abrasive cleaners is not covered by warranty.  
Electrical and mechanical components such as blowers, switches, wiring, thermodiscs, FPI remote controls, spill switches, thermopiles, thermocouples, pilot assembly  
components, and gas valves are covered for one year parts and subsidized labour* from the date of purchase. Blowers and valves replaced under warranty are considered  
repairs and continue as if new with appliance. ie. twelve (12) months from original purchase date of appliance with a minimum of three (3) months coverage from date  
of replacement.  
FPI venting components are covered parts and subsidized labour* for three (3) years from date of purchase.  
Simpson Dura-Vent venting components (Direct Vent units) are covered by Simpson Dura-Vent Inc. warranty.  
Conditions:  
Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI's option, through an accredited distributor or agent  
provided that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.  
Porcelain/Enamel - Absolute perfection is either guaranteed nor commercially possible. Any chips must be reported and inspected by an authorized dealer within three  
days of installation. Reported damage after this time will be subject to rejection.  
It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated  
for manufacturer defect.  
The authorized selling dealer is responsible for all in-field service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship  
from unauthorized service persons or dealers.  
At all times FPI reserves the right to inspect product in the field which is claimed to be defective.  
All claims must be submitted to FPI by authorized selling dealers. It is essential that all submitted claims provide all of the necessary information including customer  
name, purchase date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.  
Exclusions:  
This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim.  
At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once manufactured.  
ie. as products evolve, field modifications or upgrades will not be performed.  
FPI will not be liable for travel costs for service work.  
Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the terms of this warranty policy.  
Embers, rockwool, gaskets, door handles and paint are not covered under the terms of this warranty policy.  
Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.  
The warranty will not extend to any part which has been tampered with or altered in any way, or in our judgment has been subject to misuse, improper installation, negligence  
or accident, spillage or downdrafts caused by environmental or geographical conditions, inadequate ventilation, excessive offsets, negative air pressure caused by  
mechanical systems such as furnaces, fans, clothes dryer, etc.  
Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer.  
FPI will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.  
Performance problems due to operator error will not be covered by this warranty policy.  
Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from FPI, may nullify your  
warranty on this product.  
Any alteration to the unit which causes sooting or carboning that results in damage to the interior / exterior facia is not the responsibility of FPI.  
* Subsidy according to job scale as predetermined by FPI.  
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
47  
Regency fireplace products are designed  
withreliabilityandsimplicityinmind. In  
addition, our internal QualityAssurance  
Team carefully inspects each unit  
thoroughly before it leaves our  
door.  
Fireplace Products International  
Ltd. is pleased to extend this Lim-  
ited Lifetime Warranty to the original  
purchaser of a Regency Product.  
See the inside back cover for details.  
Register your Regency online at  
Installer:Pleasecompletethefollowinginformation  
Dealer Name & Address:______________________________________________  
__________________________________________________________________  
Installer: ___________________________________________________________  
Phone #: ___________________________________________________________  
Date Installed: ______________________________________________________  
Serial No.: _________________________________________________________  
Regency and Panorama are trademarks of FPI Fireplace Products International Ltd.  
© Copyright 2005, FPI Fireplace Products International Ltd. All rights reserved.  
Printed in Canada  
Download from Www.Somanuals.com. All Manuals Search And Download.  

PYLE Audio TV Mount PSW117ET1 User Guide
Reliance Water Heaters Water Heater 184123 000 User Guide
Rheem Water Heater GX90 550 User Guide
Rosewill Switch RHUB 210 User Guide
Samsung Portable DVD Player DVD L200 User Guide
Samsung Security Camera SCC B5396 User Guide
Sanitaire Vacuum Cleaner SC883A User Guide
Sanyo Heat Pump APR CHP1350BA User Guide
Scientific Atlanta DVR 34172 User Guide
Senco Nail Gun SN70 User Guide