Gas Fireplaces
P36 - P36D Gas Fireplace
P36 - P36D Zero Clearance Direct Vent Gas Fireplace
Model
P36-NG4
P36-LP4
P36D-NG1 P36D-LP1
Fuel Type
Natural Gas
Propane
Natural Gas
Propane
Minimum Supply
Pressure
5” W.C.
(1.25 kPa)
12” W.C.
(3.00 kPa)
5” W.C.
(1.25 kPa)
12” W.C.
(3.00 kPa)
Manifold
Pressure - High
3.8” W.C.
(0.95 kPa)
11” W.C.
(2.74 kPa)
3.8” W.C.
(0.95 kPa)
11” W.C.
(2.74 kPa)
Manifold
Pressure - Low
1.1” W.C.
(0.27 kPa)
2.9” W.C.
(0.72 kPa)
1.1” W.C.
(0.27 kPa)
2.9” W.C.
(0.72 kPa)
Orifice Size
#37 DMS
#52 DMS
#37 DMS
#52 DMS
15,500 BTU/h
(4.54 kW)
15,000 BTU/h
(3.96 kW)
15,500 BTU/h
(4.54 kW)
15,000 BTU/h
(3.96 kW)
Minimum Input
30,000 BTU/h
(8.79 kW)
30,000 BTU/h
(8.79 kW)
30,000 BTU/h
(8.79 kW)
30,000 BTU/h
(8.79 kW)
Maximum Input
4” Inner / 6 5/8” 4” Inner / 6 5/8” 4” Inner / 6 5/8” 4” Inner / 6 5/8”
Outer Outer Outer Outer
Vent Sizing
Approved Venting Systems
Flex Vent Systems:
FPI AstroCap™ Flex Vent
Rigid Pipe Vent Systems:
Simpson Dura-Vent® Direct Vent GS
American Metal Products Ameri Vent
Security Secure Vent®
Selkirk Direct-Temp.
B
A
L
Top Header
Drywall
(or other
facing)
D
C
F
H
10" (254mm)
dia. Hole through
wall Vent.
E
A
G
I
Unit Dimensions
Description
P36
P36D
M
A
B
C
D
E
F
Front Face Width
Rear Firebox Width
Front Face Height
Height w/ Standoff
Unit Depth
36” (914mm)
33-1/4” (838mm)
30-1/2” (775mm)
36” (914mm)
36” (914mm)
33-1/4” (838mm)
30-1/2” (775mm)
37” (940mm)
J
12-3/4” (324mm)
32-1/2” (826mm)
17-1/8” (435mm)
32-1/2” (826mm)
Height to Vent
Framing Dimensions Description
P36
P36D
N
G
Framing Width*
36-1/4” (921mm)
36-1/4” (921mm)***
12-3/4” (324mm)
36-1/4” (921mm)
37-1/4” (946mm)***
17-1/8” (435mm)
48” (1219mm)
H***
Framing Height* ***
Framing Depth*
O
P
K
I
Opening for gas
connection
J
Corner Wall Length
42-7/16” (1078mm)
Corner Facing Wall
Width
If using the Barcelona Surround, Kensington, Balmoral, or
K
60” (1524mm)
68” (1727mm)
*
Tripoli Screen Door please note that framing and facing must
be non combustible (12” on top and 6” on both sides) and that
the Barcelona is only approved for installation with a single
sidewall.
L
Framed Chase Ceiling
Vent Centerline Height
46” (1168mm)
46-1/2” (1181mm)
40-1/2” (1029mm)
M
40-1/2” (1029mm)
N
O
P
Gas Connection Height
Gas Connection Inset
Gas Connection Width
2” (51mm)
3-1/2” (89mm)
4” (102mm)
2” (51mm)
3-1/2” (89mm)
4” (102mm)
Please refer to Page 11 (Exterior Vent Terminations)
for additional guidelines on vent locations.
***Important: Framing height requires consideration of the hearth
depth. Dimension H = H + the thickness of installed hearth.
June 2007 Regency Product Specifications Book
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Gas Fireplaces
P36 - P36D Gas Fireplace
FPI Direct Vent System (Flex)
Snorkel Terminations
Horizontal Terminations Only
Snorkel Terminations:
These venting systems, in combination with the P36 / P36D Direct Vent
GasFireplace,havebeentestedandlistedasadirectventheatersystem
by Warnock Hersey. The location of the termination cap must conform
to the requirements in the Vent Terminal Locations diagram.
For installations requiring a vertical rise on the exterior of the building,
14-inch and 36-inch tall Snorkel Terminations and the Riser Vent are
available. Follow the same installation procedures as used for standard
Horizontal Termination. NEVER install the snorkel upside down.
FPI Direct Vent (Flex) System Termination Kits include all the parts
needed to install the P36 / P36D using a flexible vent.
FPI Kit #
Length Contains:
#946-515
4 Feet
1) 6-5/8” flexible liner (Kit length)
2) 4” flexible liner (Kit length)
3) spring spacers (3)
4) thimble (2)
5) AstroCap termination cap (1)
6) screws (12)
#946-516
10 Feet
7) tube of Mill Pac (1)
8) plated screws (8)
9) S.S. screws #8 x 1-1/2” drill point, (4)
Notes:
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from Regency may be used for Flex
installations.
3) Horizontal sections must be supported every 3 feet.
Below Grade Snorkel Installation (Dura-Vent Only)
If the Snorkel Termination must be installed below grade, i.e. basement
application, proper drainage must be provided to prevent water from
entering the Snorkel Termination. Refer to Rigid Pipe Installation
instructions for details. Do not attempt to enclose the Snorkel within the
wall, or any other type of enclosure.
Wall Thimble (2 pc)
4" (102mm)
dia. flue pipe
AstroCap
Termination Cap
Part #946-523/P
6-7/8"
(173mm) dia.
Flue pipe
Alternate Horizontal
Termination Caps
spring
spacer
Alternate:
Horizontal
Riser Vent
Terminal
Part# 640-530/P
If required by the external termination location the listed
alternate termination caps may be used. (Refer to Page 11)
June 2007 Regency Product Specifications Book
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Gas Fireplaces
P36 - P36D Gas Fireplace
Rigid Pipe Venting
Horizontal or Vertical Terminations
Vertical
Terminal
2
4
8
14
0
6
10
12
Storm Collar
Part # 953
Vinyl Siding
Standoff (Optional)
Part #950
40
38
36
34
32
Flashing
943 or 943S
Ceiling Firestop
(Part # 963)
Horizontal
Termination Cap
(Part #946-523/P)
Wall Thimble
Part # 942
Pipe Length
Adj.Pipe Length
11" - 14-5/8"
90o Elbow
Alternate Horizontal
Termination Caps
Pipe
Length
30
28
Rigid Pipe Adapter
(Part# 510-994)
26
24
Alternate:
Horizontal
Riser Vent
Terminal
Part# 640-530/P
22
20
18
16
14
12
10
If required by the external termination location the listed
alternate termination caps may be used. (Refer to Page 11)
Venting Arrangements - Vertical
Terminations
Rigid Pipe System
(Propane & Natural Gas)
The P36 / P36D is approved for a maximum 40 ft. straight vertical, with
Rigid Pipe vent systems for Propane and Natural Gas.
The lightly shaded area,
, in the diagram shows allowable venting
configurations with a maximum of two 45° elbows allowed.
The darker shaded area,
, in the diagram shows allowable venting
configurations using two 90° elbows.
8
6
•
•
•
Vent must be supported at offsets.
Horizontal sections must be supported every 3 feet
Firestops are required at each floor level and whenever
passing through a wall.
•
•
Maintain clearances to combustible materials.
Minimum of 1’ pipe section between elbows.
4
2
0
Note: Must use optional flue adapter when using Rigid Pipe (Part
# 510-994).
Max. 10’ (3m)(centerline to centerline)
Minimum 12” (305mm)
38
June 2007 Regency Product Specifications Book
Download from Www.Somanuals.com. All Manuals Search And Download.
Gas Fireplaces
P36 - P36D Gas Fireplace
Vertical Venting
with Two (2) 90° Elbows
Two 45° elbows = One 90° elbow
Option
A)
V
H
V+ V1
1’ Min.
3’ Min.
4’ Min.
5’ Min.
6’ Min.
7’ Min.
Maximum total pipe: length, of
all sections, must not exceed
30 feet.
0’ Min.
1’ Min.
2’ Min.
3’ Min.
4’ Min.
5’ Min.
2’ Max.
4’ Max.
5’ Max.
6’ Max.
7’ Max.
8’ Max.
Total horizontal sections must
not exceed 8 feet.
B)
C)
Minimum of 1 foot between
90° elbows is required.
D)
E)
F)
Vertical Venting
with Three (3) 90° Elbows
Two 45° elbows = One 90° elbow
Option
A)
V
H + H1
2’ Max.
2’ Max.
3’ Max.
4’ Max.
5’ Max.
6’ Max.
7’ Max.
8’ Max.
V+ V1
2’ Min.
3’ Min.
4’ Min.
6’ Min.
7’ Min.
8’ Min.
9’ Min.
10’ Min.
Maximum total pipe: length, of
all sections, must not exceed
30 feet.
0’ Min.
1’ Min.
2’ Min.
3’ Min.
4’ Min.
5’ Min.
6’ Min.
7’ Min.
Total horizontal sections must
not exceed 8 feet.
B)
C)
Minimum of 1 foot between
90° elbows is required.
D)
E)
F)
G)
H)
June 2007 Regency Product Specifications Book
Download from Www.Somanuals.com. All Manuals Search And Download.
39
Gas Fireplaces
P36 - P36D Gas Fireplace
Note: Must use optional flue adapter (Part # 510-994) when using
Rigid Pipe.
Venting Arrangements - Horizontal
Terminations
•
•
•
Maintain clearances to combustibles.
Horizontal vent must be supported every 3 feet.
Firestops are required at each floor level and whenever passing
through a wall.
This diagram shows all allowable combinations of vertical runs with
horizontal terminations, using one 90º elbow (two 45º elbows equal
one 90º elbow).
A vent guard may be required as per local codes, refer to page 11 for
“Exterior Vent Termination Locations”.
The lightly shaded area,
, in the diagram shows allowable
combinations when installing a P36
The darker shaded area,
, in the diagram shows additional allowable
Note: FPIDirectVentSystem(Flex)isonlyapprovedforhorizontal
terminations.
combinations when installing a P36D.
Horizontal (Feet)
0
2
4
6
8
10
12
14
16
18
20
18
16
14
12
10
8
P36D ONLY
6
4
40-1/2"
(1029mm)
Minimum
Height
2
Requirement
0
Please refer to Page 11 (Exterior Vent Terminations)
for additional guidelines on vent locations.
40
June 2007 Regency Product Specifications Book
Download from Www.Somanuals.com. All Manuals Search And Download.
Gas Fireplaces
P36 - P36D Gas Fireplace
Horizontal Venting
with Two (2) 90° Elbows
Two 45° elbows = One 90° elbow
Option
A)
V
H+ H1
2’ Max.
3’ Max.
4’ Max.
5’ Max.
6’ Max.
7’ Max.
8’ Max.
Maximum total pipe: length, of
all sections, must not exceed
30 feet.
0’ Min.
1’ Min.
2’ Min.
3’ Min.
4’ Min.
5’ Min.
6’ Min.
Total horizontal sections must
not exceed 8 feet.
B)
C)
Minimum of 1 foot between
90° elbows is required.
D)
E)
F)
F)
Horizontal Venting
with Three (3) 90° Elbows
Two 45° elbows = One 90° elbow
Option
A)
V
H
V+ V1
1’ Min.
3’ Min.
5’ Min.
7’ Min.
9’ Min.
10’ Min.
11’ Min.
12’ Min.
H + H1
2’ Max.
3’ Max.
4’ Max.
5’ Max.
6’ Max.
7’ Max.
8’ Max.
9’ Max.
Maximum total
pipe: length, of
all sections, must
not exceed 30
feet.
Total horizontal
sections must not
exceed 8 feet.
Minimum of 1
foot between
90° elbows is
required.
0’ Min.
1’ Min.
2’ Min.
3’ Min.
4’ Min.
5’ Min.
6’ Min.
7’ Min.
1’ Max.
2’ Max.
2’ Max.
2’ Max.
3’ Max.
4’ Max.
5’ Max.
6’ Max.
B)
C)
D)
E)
F)
G)
H)
June 2007 Regency Product Specifications Book
Download from Www.Somanuals.com. All Manuals Search And Download.
41
Gas Fireplaces
P36 - P36D Gas Fireplace
Vertical termination with co-linear
flex system
Required Parts:
Part #
Description
946-529
948-305
946-563
Co-linear DV Vertical Termination Cap
3” Flex - 35 ft.
The appliance must not be connected to a chimney flue
serving a separate solid fuel burning appliance.
Coaxial to Co-linear Adapter Kit which contains
the following: Co-linear Flex Adapter Outer Pipe
Inner Pipe Adapter
Masonry chimneys may take various contours which the flexible liner
will accommodate. However, keep the flexible liner as straight as
possible, avoid unnecessary bending.
510-994
945
Flue Adapter
45º Elbow
The Air Intake pipe must be attached to the inlet air collar of the
termination cap.
Alternate Approved Caps
980
Vertical Termination Cap
This appliance is designed to be attached to two 3” (76mm) co-linear
aluminium flex running the full length of the chimney. See the Venting
Arrangements for minimum and maximum heights.
991
High Wind Cap
923GK
3” Co-linear Adapter with flashing
Co-linear DV
Vertical Termination
Cap # 946-529
30
A maximum
of two certified
joiner kits
may be used
per length.
Flex Liner
#948-305 (35 ft)
Exhaust
Flue
Outer
Pipe
with Kit#
946-563
Air Intake
Horizontal Distance (Feet)
Pipe Length
Co-Linear
Flex
Adapter
with Kit#
The shaded area in the diagrams
show the allowable vertical
terminations.
Rigid Pipe Adapter
946-563
# 510-994
90 Degree
Elbow
Inner Pipe
Adapter
with Kit#
946-563
Please refer to Page 11
(Exterior Vent Terminations)
for additional guidelines on
vent locations.
42