Regency Indoor Fireplace P36D LP1 User Guide

Gas Fireplaces  
P36 - P36D Gas Fireplace  
P36 - P36D Zero Clearance Direct Vent Gas Fireplace  
Model  
P36-NG4  
P36-LP4  
P36D-NG1 P36D-LP1  
Fuel Type  
Natural Gas  
Propane  
Natural Gas  
Propane  
Minimum Supply  
Pressure  
5” W.C.  
(1.25 kPa)  
12” W.C.  
(3.00 kPa)  
5” W.C.  
(1.25 kPa)  
12” W.C.  
(3.00 kPa)  
Manifold  
Pressure - High  
3.8” W.C.  
(0.95 kPa)  
11” W.C.  
(2.74 kPa)  
3.8” W.C.  
(0.95 kPa)  
11” W.C.  
(2.74 kPa)  
Manifold  
Pressure - Low  
1.1” W.C.  
(0.27 kPa)  
2.9” W.C.  
(0.72 kPa)  
1.1” W.C.  
(0.27 kPa)  
2.9” W.C.  
(0.72 kPa)  
Orifice Size  
#37 DMS  
#52 DMS  
#37 DMS  
#52 DMS  
15,500 BTU/h  
(4.54 kW)  
15,000 BTU/h  
(3.96 kW)  
15,500 BTU/h  
(4.54 kW)  
15,000 BTU/h  
(3.96 kW)  
Minimum Input  
30,000 BTU/h  
(8.79 kW)  
30,000 BTU/h  
(8.79 kW)  
30,000 BTU/h  
(8.79 kW)  
30,000 BTU/h  
(8.79 kW)  
Maximum Input  
4” Inner / 6 5/8” 4” Inner / 6 5/8” 4” Inner / 6 5/8” 4” Inner / 6 5/8”  
Outer Outer Outer Outer  
Vent Sizing  
Approved Venting Systems  
Flex Vent Systems:  
FPI AstroCap™ Flex Vent  
Rigid Pipe Vent Systems:  
Simpson Dura-Vent® Direct Vent GS  
American Metal Products Ameri Vent  
Security Secure Vent®  
Selkirk Direct-Temp.  
B
A
L
Top Header  
Drywall  
(or other  
facing)  
D
C
F
H
10" (254mm)  
dia. Hole through  
wall Vent.  
E
A
G
I
Unit Dimensions  
Description  
P36  
P36D  
M
A
B
C
D
E
F
Front Face Width  
Rear Firebox Width  
Front Face Height  
Height w/ Standoff  
Unit Depth  
36” (914mm)  
33-1/4” (838mm)  
30-1/2” (775mm)  
36” (914mm)  
36” (914mm)  
33-1/4” (838mm)  
30-1/2” (775mm)  
37” (940mm)  
J
12-3/4” (324mm)  
32-1/2” (826mm)  
17-1/8” (435mm)  
32-1/2” (826mm)  
Height to Vent  
Framing Dimensions Description  
P36  
P36D  
N
G
Framing Width*  
36-1/4” (921mm)  
36-1/4” (921mm)***  
12-3/4” (324mm)  
36-1/4” (921mm)  
37-1/4” (946mm)***  
17-1/8” (435mm)  
48” (1219mm)  
H***  
Framing Height* ***  
Framing Depth*  
O
P
K
I
Opening for gas  
connection  
J
Corner Wall Length  
42-7/16” (1078mm)  
Corner Facing Wall  
Width  
If using the Barcelona Surround, Kensington, Balmoral, or  
K
60” (1524mm)  
68” (1727mm)  
*
Tripoli Screen Door please note that framing and facing must  
be non combustible (12” on top and 6” on both sides) and that  
the Barcelona is only approved for installation with a single  
sidewall.  
L
Framed Chase Ceiling  
Vent Centerline Height  
46” (1168mm)  
46-1/2” (1181mm)  
40-1/2” (1029mm)  
M
40-1/2” (1029mm)  
N
O
P
Gas Connection Height  
Gas Connection Inset  
Gas Connection Width  
2” (51mm)  
3-1/2” (89mm)  
4” (102mm)  
2” (51mm)  
3-1/2” (89mm)  
4” (102mm)  
Please refer to Page 11 (Exterior Vent Terminations)  
for additional guidelines on vent locations.  
***Important: Framing height requires consideration of the hearth  
depth. Dimension H = H + the thickness of installed hearth.  
June 2007 Regency Product Specifications Book  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Gas Fireplaces  
P36 - P36D Gas Fireplace  
FPI Direct Vent System (Flex)  
Snorkel Terminations  
Horizontal Terminations Only  
Snorkel Terminations:  
These venting systems, in combination with the P36 / P36D Direct Vent  
GasFireplace,havebeentestedandlistedasadirectventheatersystem  
by Warnock Hersey. The location of the termination cap must conform  
to the requirements in the Vent Terminal Locations diagram.  
For installations requiring a vertical rise on the exterior of the building,  
14-inch and 36-inch tall Snorkel Terminations and the Riser Vent are  
available. Follow the same installation procedures as used for standard  
Horizontal Termination. NEVER install the snorkel upside down.  
FPI Direct Vent (Flex) System Termination Kits include all the parts  
needed to install the P36 / P36D using a flexible vent.  
FPI Kit #  
Length Contains:  
#946-515  
4 Feet  
1) 6-5/8” flexible liner (Kit length)  
2) 4” flexible liner (Kit length)  
3) spring spacers (3)  
4) thimble (2)  
5) AstroCap termination cap (1)  
6) screws (12)  
#946-516  
10 Feet  
7) tube of Mill Pac (1)  
8) plated screws (8)  
9) S.S. screws #8 x 1-1/2” drill point, (4)  
Notes:  
1) Liner sections should be continuous without any joints or seams.  
2) Only Flex pipe purchased from Regency may be used for Flex  
installations.  
3) Horizontal sections must be supported every 3 feet.  
Below Grade Snorkel Installation (Dura-Vent Only)  
If the Snorkel Termination must be installed below grade, i.e. basement  
application, proper drainage must be provided to prevent water from  
entering the Snorkel Termination. Refer to Rigid Pipe Installation  
instructions for details. Do not attempt to enclose the Snorkel within the  
wall, or any other type of enclosure.  
Wall Thimble (2 pc)  
4" (102mm)  
dia. flue pipe  
AstroCap  
Termination Cap  
Part #946-523/P  
6-7/8"  
(173mm) dia.  
Flue pipe  
Alternate Horizontal  
Termination Caps  
spring  
spacer  
Alternate:  
Horizontal  
Riser Vent  
Terminal  
Part# 640-530/P  
If required by the external termination location the listed  
alternate termination caps may be used. (Refer to Page 11)  
June 2007 Regency Product Specifications Book  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Gas Fireplaces  
P36 - P36D Gas Fireplace  
Rigid Pipe Venting  
Horizontal or Vertical Terminations  
Vertical  
Terminal  
2
4
8
14  
0
6
10  
12  
Storm Collar  
Part # 953  
Vinyl Siding  
Standoff (Optional)  
Part #950  
40  
38  
36  
34  
32  
Flashing  
943 or 943S  
Ceiling Firestop  
(Part # 963)  
Horizontal  
Termination Cap  
(Part #946-523/P)  
Wall Thimble  
Part # 942  
Pipe Length  
Adj.Pipe Length  
11" - 14-5/8"  
90o Elbow  
Alternate Horizontal  
Termination Caps  
Pipe  
Length  
30  
28  
Rigid Pipe Adapter  
(Part# 510-994)  
26  
24  
Alternate:  
Horizontal  
Riser Vent  
Terminal  
Part# 640-530/P  
22  
20  
18  
16  
14  
12  
10  
If required by the external termination location the listed  
alternate termination caps may be used. (Refer to Page 11)  
Venting Arrangements - Vertical  
Terminations  
Rigid Pipe System  
(Propane & Natural Gas)  
The P36 / P36D is approved for a maximum 40 ft. straight vertical, with  
Rigid Pipe vent systems for Propane and Natural Gas.  
The lightly shaded area,  
, in the diagram shows allowable venting  
configurations with a maximum of two 45° elbows allowed.  
The darker shaded area,  
, in the diagram shows allowable venting  
configurations using two 90° elbows.  
8
6
Vent must be supported at offsets.  
Horizontal sections must be supported every 3 feet  
Firestops are required at each floor level and whenever  
passing through a wall.  
Maintain clearances to combustible materials.  
Minimum of 1’ pipe section between elbows.  
4
2
0
Note: Must use optional flue adapter when using Rigid Pipe (Part  
# 510-994).  
Max. 10’ (3m)(centerline to centerline)  
Minimum 12” (305mm)  
38  
June 2007 Regency Product Specifications Book  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Gas Fireplaces  
P36 - P36D Gas Fireplace  
Vertical Venting  
with Two (2) 90° Elbows  
Two 45° elbows = One 90° elbow  
Option  
A)  
V
H
V+ V1  
1’ Min.  
3’ Min.  
4’ Min.  
5’ Min.  
6’ Min.  
7’ Min.  
Maximum total pipe: length, of  
all sections, must not exceed  
30 feet.  
0’ Min.  
1’ Min.  
2’ Min.  
3’ Min.  
4’ Min.  
5’ Min.  
2’ Max.  
4’ Max.  
5’ Max.  
6’ Max.  
7’ Max.  
8’ Max.  
Total horizontal sections must  
not exceed 8 feet.  
B)  
C)  
Minimum of 1 foot between  
90° elbows is required.  
D)  
E)  
F)  
Vertical Venting  
with Three (3) 90° Elbows  
Two 45° elbows = One 90° elbow  
Option  
A)  
V
H + H1  
2’ Max.  
2’ Max.  
3’ Max.  
4’ Max.  
5’ Max.  
6’ Max.  
7’ Max.  
8’ Max.  
V+ V1  
2’ Min.  
3’ Min.  
4’ Min.  
6’ Min.  
7’ Min.  
8’ Min.  
9’ Min.  
10’ Min.  
Maximum total pipe: length, of  
all sections, must not exceed  
30 feet.  
0’ Min.  
1’ Min.  
2’ Min.  
3’ Min.  
4’ Min.  
5’ Min.  
6’ Min.  
7’ Min.  
Total horizontal sections must  
not exceed 8 feet.  
B)  
C)  
Minimum of 1 foot between  
90° elbows is required.  
D)  
E)  
F)  
G)  
H)  
June 2007 Regency Product Specifications Book  
Download from Www.Somanuals.com. All Manuals Search And Download.  
39  
Gas Fireplaces  
P36 - P36D Gas Fireplace  
Note: Must use optional flue adapter (Part # 510-994) when using  
Rigid Pipe.  
Venting Arrangements - Horizontal  
Terminations  
Maintain clearances to combustibles.  
Horizontal vent must be supported every 3 feet.  
Firestops are required at each floor level and whenever passing  
through a wall.  
This diagram shows all allowable combinations of vertical runs with  
horizontal terminations, using one 90º elbow (two 45º elbows equal  
one 90º elbow).  
A vent guard may be required as per local codes, refer to page 11 for  
“Exterior Vent Termination Locations”.  
The lightly shaded area,  
, in the diagram shows allowable  
combinations when installing a P36  
The darker shaded area,  
, in the diagram shows additional allowable  
Note: FPIDirectVentSystem(Flex)isonlyapprovedforhorizontal  
terminations.  
combinations when installing a P36D.  
Horizontal (Feet)  
0
2
4
6
8
10  
12  
14  
16  
18  
20  
18  
16  
14  
12  
10  
8
P36D ONLY  
6
4
40-1/2"  
(1029mm)  
Minimum  
Height  
2
Requirement  
0
Please refer to Page 11 (Exterior Vent Terminations)  
for additional guidelines on vent locations.  
40  
June 2007 Regency Product Specifications Book  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Gas Fireplaces  
P36 - P36D Gas Fireplace  
Horizontal Venting  
with Two (2) 90° Elbows  
Two 45° elbows = One 90° elbow  
Option  
A)  
V
H+ H1  
2’ Max.  
3’ Max.  
4’ Max.  
5’ Max.  
6’ Max.  
7’ Max.  
8’ Max.  
Maximum total pipe: length, of  
all sections, must not exceed  
30 feet.  
0’ Min.  
1’ Min.  
2’ Min.  
3’ Min.  
4’ Min.  
5’ Min.  
6’ Min.  
Total horizontal sections must  
not exceed 8 feet.  
B)  
C)  
Minimum of 1 foot between  
90° elbows is required.  
D)  
E)  
F)  
F)  
Horizontal Venting  
with Three (3) 90° Elbows  
Two 45° elbows = One 90° elbow  
Option  
A)  
V
H
V+ V1  
1’ Min.  
3’ Min.  
5’ Min.  
7’ Min.  
9’ Min.  
10’ Min.  
11’ Min.  
12’ Min.  
H + H1  
2’ Max.  
3’ Max.  
4’ Max.  
5’ Max.  
6’ Max.  
7’ Max.  
8’ Max.  
9’ Max.  
Maximum total  
pipe: length, of  
all sections, must  
not exceed 30  
feet.  
Total horizontal  
sections must not  
exceed 8 feet.  
Minimum of 1  
foot between  
90° elbows is  
required.  
0’ Min.  
1’ Min.  
2’ Min.  
3’ Min.  
4’ Min.  
5’ Min.  
6’ Min.  
7’ Min.  
1’ Max.  
2’ Max.  
2’ Max.  
2’ Max.  
3’ Max.  
4’ Max.  
5’ Max.  
6’ Max.  
B)  
C)  
D)  
E)  
F)  
G)  
H)  
June 2007 Regency Product Specifications Book  
Download from Www.Somanuals.com. All Manuals Search And Download.  
41  
Gas Fireplaces  
P36 - P36D Gas Fireplace  
Vertical termination with co-linear  
flex system  
Required Parts:  
Part #  
Description  
946-529  
948-305  
946-563  
Co-linear DV Vertical Termination Cap  
3” Flex - 35 ft.  
The appliance must not be connected to a chimney flue  
serving a separate solid fuel burning appliance.  
Coaxial to Co-linear Adapter Kit which contains  
the following: Co-linear Flex Adapter Outer Pipe  
Inner Pipe Adapter  
Masonry chimneys may take various contours which the flexible liner  
will accommodate. However, keep the flexible liner as straight as  
possible, avoid unnecessary bending.  
510-994  
945  
Flue Adapter  
45º Elbow  
The Air Intake pipe must be attached to the inlet air collar of the  
termination cap.  
Alternate Approved Caps  
980  
Vertical Termination Cap  
This appliance is designed to be attached to two 3” (76mm) co-linear  
aluminium flex running the full length of the chimney. See the Venting  
Arrangements for minimum and maximum heights.  
991  
High Wind Cap  
923GK  
3” Co-linear Adapter with flashing  
Co-linear DV  
Vertical Termination  
Cap # 946-529  
30  
A maximum  
of two certified  
joiner kits  
may be used  
per length.  
Flex Liner  
#948-305 (35 ft)  
Exhaust  
Flue  
Outer  
Pipe  
with Kit#  
946-563  
Air Intake  
Horizontal Distance (Feet)  
Pipe Length  
Co-Linear  
Flex  
Adapter  
with Kit#  
The shaded area in the diagrams  
show the allowable vertical  
terminations.  
Rigid Pipe Adapter  
946-563  
# 510-994  
90 Degree  
Elbow  
Inner Pipe  
Adapter  
with Kit#  
946-563  
Please refer to Page 11  
(Exterior Vent Terminations)  
for additional guidelines on  
vent locations.  
42  
June 2007 Regency Product Specifications Book  
Download from Www.Somanuals.com. All Manuals Search And Download.  

PYLE Audio Stereo Amplifier AZR6XA User Guide
Q See Digital Camera QD113P User Guide
Radio Shack CD Player PDCD810 User Guide
RCA MP3 Player TH20 User Guide
RCA Stereo System 5643738A User Guide
Riccar Sewing Machine RL624 User Guide
Roland Electronic Keyboard AT 100 User Guide
Samsung Cell Phone SPH M900 User Guide
Sanyo Battery Charger HR AUC User Guide
Sears Power Supply 20071495 User Guide