Gas Fireplaces
P33 Gas Fireplace
P33 Zero Clearance Direct Vent Gas Fireplace
P33 WITH THE FLUSH OR BAY FRONT
Model
P33-NG4
Natural Gas
P33-LP4
Fuel Type
Propane
Minimum Supply Pressure
Manifold Pressure - High
Manifold Pressure - Low
5” W.C. (1.25 kPa)
3.8” W.C. (0.95 kPa)
1.1” W.C. (0.27 kPa)
12” W.C. (3.00 kPa)
11” W.C. (2.74 kPa)
3.3” W.C. (0.82 kPa)
#44 DMS - 0-2000ft
#45 DMS - 2000-4500ft
Orifice Size
#54 DMS
Minimum Input
Altitude 0-2000 ft. (0-610m)
12,500 BTU/h
(3.66 kW)
10,500 BTU/h
(3.07 kW)
Minimum Input
Altitude 2000-4500 ft. (610-1372m)
10,500 BTU/h
(3.07 kW)
Maximum Input
Altitude 0-2000 ft. (0-610m)
22,500 BTU/h
(6.59 kW)
21,500 BTU/h
(6.30 kW)
Maximum Input
Altitude 2000-4500 ft. (610-1372m)
21,000 BTU/h
(6.15 kW)
Vent Sizing
4” Inner / 6 5/8” Outer
4” Inner / 6 5/8” Outer
Approved Venting Systems
Flex Vent Systems:
FPI AstroCap™ Flex Vent
Rigid Pipe Vent Systems:
Simpson Direct Vent Pro®
American Metal Products® Amerivent Direct
Security Secure Vent®
Selkirk Direct-Temp™
Metal-Fab® Sure Seal
L
B
Top Header
Drywall
(or other
facing)
A
H
10" (254mm)
dia. Hole through
wall Vent.
C D
G
F
I
M
E
A
Q
R
Unit Dimensions
Description
P33
J
A
B
C
D
E
F
Front Face Width
Rear Firebox Width
Front Face Height
Height w/ Standoff
Unit Depth
33” (838mm)
23” (584mm)
N
29” (737mm)
31 1/2” (800mm)
12-3/4” (324mm)
28 1/2” (724mm)
O
P
K
Opening for gas
connection
Firebox Height
Framing Dimensions Description
P33
Dimension
Description
P33
G
Framing Width
33-1/4” (845mm)
31-3/4” (806mm)***
N
O
P
Gas Connection Height
Gas Connection Inset
Gas Connection Width
1 1/2” (38mm)
4” (102mm)
3” (76mm)
H***
Framing Height***
Vertical
Horizontal
19 1/2” (495mm) Vertical Rise
16 1/2” (419mm) Rigid 12-3/4” (324mm) Flex
Framing
Depth
I
Q
Minimum Framing Depth
16 1/2” (419mm) Rigid
/
/
12-3/4” (324mm) Flex
J
Corner Wall Length
37 1/2” (953mm)
53-1/4” (1353mm)
Maximum Framing Depth
(including wall thickness)
R
40 1/2” (419mm) Rigid
36-3/4” (324mm) Flex
K
L
Corner Facing Wall Width
Framed Chase Ceiling
36” (914mm) Rigid
30” (762mm) Rigid
32” (813mm) Flex
M
Vent Centerline Height
26” (660mm) Flex
Please refer to Exterior Vent Terminations for
additional guidelines on vent locations.
***Important: Framing height requires consideration of the hearth
depth. Dimension H = H + the thickness of installed hearth.
28
August 2008 Product Specifications Book
Download from Www.Somanuals.com. All Manuals Search And Download.
Gas Fireplaces
P33 Gas Fireplace
Framing and Finishing
1) Determine the total thickness of facing material (e.g. drywall plus
ceramic tiles) to allow the finished surface to be flush with the front
of the unit. Total facing thickness can vary from 1/2” (13mm) to 1-¼”
(32mm) thick.
2) Frame in the enclosure for the unit with framing material.
3) For exterior walls, insulate the enclosure to the same degree as
the rest of the house, apply vapor barrier and drywall, as per local
installation codes. (Do not insulate the fireplace itself.)
4) The top of the unit must not be closer than 30” (762mm) to the
ceiling.
5) Combustible material may be brought up to the top and
sides of the unit and be covered with ceramic tiles, bricks,
rock or other suitable combustible finishing materials.
Note: The unit does not have to be completely enclosed in a
chase. The clearance on top of the unit is 0” to the standoffs
so combustible building materials can be laid directly on top
of the standoffs. You must maintain proper clearances from
the vent to combustible materials (See Below).
Vent Clearances
Horizontal - Top
Horizontal - Side
Horizontal - Bottom
Vertical - Flex
Clearance Dimension
2-1/2” (64mm)
1-1/2” (38mm)
1-1/2” (38mm)
1-1/2” (38mm)
Vertical - Rigid
1-1/4” (32mm)
WARNING
Failure to maintain required clearances is a major cause of
chimney related fires. Installation of this fireplace must comply
with these clearances.
Combustible Mantels
Because of the extreme heat this fireplace emits, the mantel
clearances are critical. Combustible mantel clearances from top of
the louvers are shown in the diagram below. Mantel may be installed
anywhere in the shaded area or higher.
6) Use metal studs for framing where the minimum clearance from
the vent to combustible material cannot be maintained.
Mantel Clearances
0
12 10
8
6
4
2
Clearance Requirements
Drywall
12"(305mm)
7-1/2"(191mm)
3-1/2"(89mm)
D
C
B
C
D
A
F
0
Top of
Unit
B
A
B
Side View
Mantel Clearances
A
B
C
D
Front
29” (737mm)
11” (279mm)
9” (229mm)
7” (178mm)
Note: If desired a non-combustible mantel may be installed at a
lower height.
E
Note: Ensure the paint that is used on the mantel and the facing
is “heat resistant” or the paint may discolour.
Clearance:
Dimension
7” (178mm)
Measured From:
Minimum (Additional on this page)
Side of installed front
Mantel Leg Clearances
Combustible mantel leg clearances as per diagram below:
A: Mantel Height
B: Sidewall
7-1/2” (191mm)
30” (762mm)
12” (305mm)
48” (1219mm)
36” (914mm)
Clearances are from the finished edge of the unit or an installed front.
C: Ceiling
Top of installed unit
D: Mantel Depth
E: Alcove Width
F: Alcove Depth
Maximum (Additional on this page)
Sidewall to Sidewall (Minimum)
Front to back wall (Maximum)
Top of Hearth must not be higher than the base of the firebox.
Maximum
1-1/2” projection at 2”
minimum clearance.
30
August 2008 Product Specifications Book
Download from Www.Somanuals.com. All Manuals Search And Download.
Gas Fireplaces
P33 Gas Fireplace
Clearance Requirements with
Contemporary Faceplate
Combustible Mantels with
Contemporary Faceplate
Because of the extreme heat this fireplace emits, the mantel
clearances are critical. Combustible mantel clearances from top of
the louvers are shown in the diagram below. Mantel may be installed
anywhere in the shaded area or higher.
C
C
B
Close to Ceiling
*Note: All measurements are from the top/side
of the unit, not optional front.
Clearance:
Dimension
Measured
From:
A: *Front Floor Clearance
(min.)
1" (25mm)
Underside of
Unit
B: *Sidewall
7-1/2" (241mm)
Side of Unit
C: *Ceiling
(room and/or alcove)
30" (889mm)
48" (1219mm)
Top of Unit
D: Alcove Width
Sidewall to
Sidewall
Mantel Leg Clearances with
Contemporary Faceplate
Combustible mantel leg clearances from side of unit as per diagram
below:
(Minimum)
Front to
Back Wall
(Maximum)
E: Alcove Depth
36" (914mm)
Clearances are from the finished edge of the unit or an installed front.
Flue Clearances to
Combustibles
Horizontal - Top
2-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/4"
Horiztonal - Side
Horiztonal - Bottom
Vertical (Flex Vent)
Vertical (Rigid)
Top View
WARNING
Failure to maintain required clearances is a major cause of chimney related fires.
Installation of this fireplace must comply with these clearances
Please note: Due to ongoing product development, product appearance and specifications
are subject to change without notice.
WARNING
Fire hazard is an extreme risk
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fireplace and vent
system be installed only in accordance with these instructions.
Caution Requirements
The top, back and sides of the fireplace are defined by
standoffs. The metal ends of the standoff may NOT be
recessed into combustible construction.
August 2008 Product Specifications Book
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Gas Fireplaces
P33 Gas Fireplace
FPI Direct Vent System (Flex)
Horizontal Terminations Only
Important
When installing Cabinet Mantels: the wall thimble must be secured
first and venting must be attached to unit before sliding into final
position.
This venting system, in combination with the P33 Direct Vent Gas
Fireplace, have been tested and listed as a direct vent heater system by
Warnock Hersey. The location of the termination cap must conform to the
requirements in the Vent Terminal Locations diagram, see manual.
FPI Direct Vent (Flex) System Termination Kits include all the parts
needed to install the P33 using a flexible vent.
Snorkel Terminations
Snorkel Terminations:
FPI Kit #
Length Contains:
For installations requiring a vertical rise on the exterior of the building,
14-inch and 36-inch tall Snorkel Terminations and the Riser Vents are
available. Follow the same installation procedures as used for standard
Horizontal Termination. NEVER install the snorkel upside down.
#946-513
2 Feet
4 Feet
10 Feet
1) 6-5/8” flexible liner (Kit length)
2) 4” flexible liner (Kit length)
3) spring spacers (3)
4) thimble (2)
5) AstroCap termination cap (1)
6) screws (12)
#946-515
#946-516
Notes:
Riser Vent
Termination
7) tube of Mill Pac (1)
8) plated screws (8)
9) S.S. screws #8 x 1-1/2” drill point, (4)
Dura-Vent
Snorkel
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from Regency may be used for Flex
installations.
Min. 12"*
(305mm)
3) Horizontal sections must be supported every 3 feet.
Min. 6-1/4"*
(159mm)
Below Grade Snorkel Installation (Dura-Vent Only)
Wall Thimble (2 pc)
If the Snorkel Termination must be installed below grade, i.e. basement
application, proper drainage must be provided to prevent water from
entering the Snorkel Termination. Refer to Rigid Pipe Installation
instructions for details. Do not attempt to enclose the Snorkel within the
wall, or any other type of enclosure.
AstroCapTM
Termination Cap
(Part# 946-523/P)
4" (102mm)
dia. flue pipe
spring
spacer
6-7/8"
(173mm)
dia. Flue pipe
Dura-Vent
Snorkel
Alternate Horizontal
Termination Caps
Window
Well
Adequate
drainage
Gravel
If required by the external termination location the listed
alternate termination caps may be used.
32
August 2008 Product Specifications Book
Download from Www.Somanuals.com. All Manuals Search And Download.
Gas Fireplaces
P33 Gas Fireplace
Rigid Pipe Venting
Horizontal or Vertical Terminations
2
4
8
14
0
6
10
12
40
38
36
34
32
30
28
Alternate Horizontal
Termination Caps
26
24
22
20
18
16
14
12
10
If required by the external termination location the listed
alternate termination caps may be used. (Refer to Page 11)
Venting Arrangements - Vertical
Terminations
Rigid Pipe System
(Propane & Natural Gas)
The P33 is approved for a maximum 40 ft. straight vertical, with Rigid
Pipe vent systems for Propane and Natural Gas.
The lightly shaded area,
, in the diagram shows allowable venting
configurations with a maximum two 45° elbows.
The darker shaded area,
configurations using one 45° and one 90° elbow.
, in the diagram shows allowable venting
8
6
•
•
•
Vent must be supported at offsets.
Horizontal sections must be supported every 3 feet.
Firestops are required at each floor level and whenever
passing through a wall.
•
•
Maintain clearances to combustible materials.
Minimum of 1’ pipe section between elbows.
4
2
0
Note: Must use optional rigid pipe adapter when using Rigid Pipe
(Part # 510-994).
* Unit must be raised by 1” when using Contemporary Faceplate
Max. 10’ (3m)(centerline to centerline)
Minimum 12” (305mm)
August 2008 Product Specifications Book
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Gas Fireplaces
P33 Gas Fireplace
Vertical Venting with Two (2) 90° Elbows
Vertical Venting with Three (3) 90°
Elbows - Initial vertical section.
Two 45° elbows = One 90° elbow
- Initial vertical section.
Two 45° elbows = One 90° elbow
Option
A)
V
H
V+ V1
2’ Min.
3’ Min.
4’ Min.
5’ Min.
6’ Min.
Maximum total pipe: length, of
all sections, must not exceed
30 feet.
Total horizontal sections must
not exceed 8 feet.
Option
A)
V
H + H1
3’ Max.
4’ Max.
5’ Max.
6’ Max.
7’ Max.
8’ Max.
V+ V1
4’ Min.
6’ Min.
7’ Min.
8’ Min.
9’ Min.
10’ Min.
Maximum total pipe: length, of
all sections, must not exceed
30 feet.
Total horizontal sections must
not exceed 8 feet.
1’ Min.
2’ Min.
3’ Min.
4’ Min.
5’ Min.
4’ Max.
5’ Max.
6’ Max.
7’ Max.
8’ Max.
2’ Min.
3’ Min.
4’ Min.
5’ Min.
6’ Min.
7’ Min.
B)
B)
C)
C)
Minimum of 1 foot between
90° elbows is required.
Minimum of 1 foot between
90° elbows is required.
D)
D)
E)
E)
F)
Vertical Venting with Two (2) 90° Elbows
- Initial horizontal section.
Vertical Venting with Three (3) 90°
Elbows - Initial horizontal section.
Two 45° elbows = One 90° elbow
Two 45° elbows = One 90° elbow
Option
A)
H + H1
2’ Max.
3’ Max.
4’ Max.
5’ Max.
6’ Max.
V
Maximum total pipe: length, of
all sections, must not exceed
30 feet.
2’ Min.
3’ Min.
4’ Min.
5’ Min.
6’ Min.
Option
A)
H
V
H + H1
3’ Max.
4’ Max.
5’ Max.
6’ Max.
7’ Max.
V+ V1 Maximum total pipe:
Total horizontal sections must
not exceed 6 feet.
Minimum of 1 foot between
90° elbows is required.
B)
length, of all sections,
1’ Max.
2’ Max.
3’ Max.
4’ Max.
5’ Max.
1’ Min.
2’ Min.
3’ Min.
4’ Min.
5’ Min.
3’ Min.
5’ Min.
7’ Min.
9’ Min.
11’ Min.
must not exceed 30
feet.
C)
B)
Total horizontal sections
must not exceed 7
feet.
D)
E)
C)
Minimum of 1 foot
between 90° elbows
is required.
D)
E)
34
August 2008 Product Specifications Book
Download from Www.Somanuals.com. All Manuals Search And Download.
Gas Fireplaces
P33 Gas Fireplace
•
•
•
Maintain clearances to combustibles.
Venting Arrangements - Horizontal
Terminations
Horizontal vent must be supported every 3 feet.
Firestops are required at each floor level and whenever passing
through a wall.
This lightly shaded area of the diagram shows allowable combinations
of vertical runs with horizontal terminations, using one 45° and one
90° elbow (two 45ºelbows equal one 90° elbow).
A vent guard may be required as per local codes, refer to Exterior
Vent Termination Locations.
Note: Must use optional rigid pipe adapter (Part # 510-994) when
using Rigid Pipe.
Note: FPIDirectVentSystem(Flex)isonlyapprovedforhorizontal
terminations.
* Unit must be raised by 1” when using
Contemporary Faceplate
Please refer to Exterior Vent Terminations for
additional guidelines on vent locations.
August 2008 Product Specifications Book
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Gas Fireplaces
P33 Gas Fireplace
Horizontal Venting with Two (2) 90°
Horizontal Venting with Three (3) 90°
Elbows - Initial vertical section.
Two 45° elbows = One 90° elbow
Elbows - Initial vertical section.
Two 45° elbows = One 90° elbow
Option
A)
V
H+ H1
3’ Max.
4’ Max.
5’ Max.
6’ Max.
7’ Max.
8’ Max.
Maximum total pipe: length, of
all sections, must not exceed
30 feet.
Total horizontal sections must
not exceed 8 feet.
Option
A)
V
H
V+ V1
3’ Min.
4’ Min.
6’ Min.
8’ Min.
10’ Min.
12’ Min.
H + H1
4’ Max.
5’ Max.
6’ Max.
7’ Max.
8’ Max.
9’ Max.
Maximum total
pipe: length, of
all sections, must
not exceed 30
feet.
Total horizontal
sections must not
exceed 8 feet.
Minimum of 1
foot between
90° elbows is
required.
1’ Min.
2’ Min.
3’ Min.
4’ Min.
5’ Min.
6’ Min.
2’ Min.
3’ Min.
4’ Min.
5’ Min.
6’ Min.
7’ Min.
1’ Max.
2’ Max.
3’ Max.
4’ Max.
5’ Max.
6’ Max.
B)
B)
C)
C)
Minimum of 1 foot between
90° elbows is required.
D)
D)
E)
E)
F)
F)
Horizontal Venting with Two (2) 90°
Elbows - Initial horizontal section.
Two 45° elbows = One 90° elbow
Horizontal Venting with Three (3) 90°
Elbows - Initial horizontal section.
Two 45° elbows = One 90° elbow
Option
A)
H
V
H + H1
3’ Max.
5’ Max.
6’ Max.
7’ Max.
8’ Max.
Maximum total pipe: length, of
all sections, must not exceed
30 feet.
1’ Max.
2’ Max.
3’ Max.
4’ Max.
5’ Max.
1’ Min.
2’ Min.
4’ Min.
6’ Min.
8’ Min.
Option
A)
H
V
H + H1 + H2 Maximum total pipe:
Total horizontal sections must
not exceed 8 feet.
Minimum of 1 foot between
90° elbows is required.
B)
length, of all sections,
C)
1’ Max.
2’ Max.
3’ Max.
4’ Max.
5’ Max.
6’ Max.
1’ Min.
3’ Min.
5’ Min.
7’ Min.
9’ Min.
11’ Min.
3’ Max.
5’ Max.
6’ Max.
7’ Max.
8’ Max.
9’ Max.
must not exceed 30
feet.
D)
B)
Total horizontal sections
must not exceed 7
feet.
E)
C)
Minimum of 1 foot
between 90° elbows
is required.
D)
E)
F)
36
August 2008 Product Specifications Book
Download from Www.Somanuals.com. All Manuals Search And Download.
Gas Fireplaces
P33 Gas Fireplace
Vertical termination with co-linear
Required Parts:
Part #
flex system
Description
946-529
Co-linear DV Vertical Termination Cap
3” Flex - 35 ft.
The appliance must not be connected to a chimney flue
serving a separate solid fuel burning appliance.
948-305
946-563
Coaxial to Co-linear Adapter Kit
Rigid Pipe Adapter
510-994
Masonry chimneys may take various contours which the flexible liner
will accommodate. However, keep the flexible liner as straight as
possible, avoid unnecessary bending.
58dva-E45
45º Elbow
Alternate Approved Caps
The Air Intake pipe must be attached to the inlet air collar of the
termination cap.
46dva-VC
46dva-VCH
46dva-GK
Vertical Termination Cap
High Wind Cap
This appliance is designed to be attached to two 3” (76mm) co-linear
aluminium flex running the full length of the chimney. See the Venting
Arrangements for minimum and maximum heights.
3” Co-linear Adapter with flashing
Co-linear DV
Vertical Termination
Cap # 946-529
30
A maximum
of two certified
joiner kits
may be used
per length.
Flex Liner
#948-305
35 ft (11m)
Exhaust
Flue
Outer
Pipe
with Kit#
946-563
Air Intake
Pipe Length
Co-Linea
Flex
Rigid Pipe Adapter
Adapter
# 510-994
with Kit#
946-563
45o Elbow
Horizontal Distance (Feet)
Inner Pipe
Adapter
with Kit#
946-563
The shaded area in the diagrams show the allowable vertical
terminations.
Please refer to Exterior Vent Terminations for
additional guidelines on vent locations.