Regency Indoor Fireplace 510 994 User Guide

Gas Fireplaces  
P33 Gas Fireplace  
P33 Zero Clearance Direct Vent Gas Fireplace  
P33 WITH THE FLUSH OR BAY FRONT  
Model  
P33-NG4  
Natural Gas  
P33-LP4  
Fuel Type  
Propane  
Minimum Supply Pressure  
Manifold Pressure - High  
Manifold Pressure - Low  
5” W.C. (1.25 kPa)  
3.8” W.C. (0.95 kPa)  
1.1” W.C. (0.27 kPa)  
12” W.C. (3.00 kPa)  
11” W.C. (2.74 kPa)  
3.3” W.C. (0.82 kPa)  
#44 DMS - 0-2000ft  
#45 DMS - 2000-4500ft  
Orice Size  
#54 DMS  
Minimum Input  
Altitude 0-2000 ft. (0-610m)  
12,500 BTU/h  
(3.66 kW)  
10,500 BTU/h  
(3.07 kW)  
Minimum Input  
Altitude 2000-4500 ft. (610-1372m)  
10,500 BTU/h  
(3.07 kW)  
Maximum Input  
Altitude 0-2000 ft. (0-610m)  
22,500 BTU/h  
(6.59 kW)  
21,500 BTU/h  
(6.30 kW)  
Maximum Input  
Altitude 2000-4500 ft. (610-1372m)  
21,000 BTU/h  
(6.15 kW)  
Vent Sizing  
4” Inner / 6 5/8” Outer  
4” Inner / 6 5/8” Outer  
Approved Venting Systems  
Flex Vent Systems:  
FPI AstroCap™ Flex Vent  
Rigid Pipe Vent Systems:  
Simpson Direct Vent Pro®  
American Metal Products® Amerivent Direct  
Security Secure Vent®  
Selkirk Direct-Temp™  
Metal-Fab® Sure Seal  
L
B
Top Header  
Drywall  
(or other  
facing)  
A
H
10" (254mm)  
dia. Hole through  
wall Vent.  
C D  
G
F
I
M
E
A
Q
R
Unit Dimensions  
Description  
P33  
J
A
B
C
D
E
F
Front Face Width  
Rear Firebox Width  
Front Face Height  
Height w/ Standoff  
Unit Depth  
33” (838mm)  
23” (584mm)  
N
29” (737mm)  
31 1/2” (800mm)  
12-3/4” (324mm)  
28 1/2” (724mm)  
O
P
K
Opening for gas  
connection  
Firebox Height  
Framing Dimensions Description  
P33  
Dimension  
Description  
P33  
G
Framing Width  
33-1/4” (845mm)  
31-3/4” (806mm)***  
N
O
P
Gas Connection Height  
Gas Connection Inset  
Gas Connection Width  
1 1/2” (38mm)  
4” (102mm)  
3” (76mm)  
H***  
Framing Height***  
Vertical  
Horizontal  
19 1/2” (495mm) Vertical Rise  
16 1/2” (419mm) Rigid 12-3/4” (324mm) Flex  
Framing  
Depth  
I
Q
Minimum Framing Depth  
16 1/2” (419mm) Rigid  
/
/
12-3/4” (324mm) Flex  
J
Corner Wall Length  
37 1/2” (953mm)  
53-1/4” (1353mm)  
Maximum Framing Depth  
(including wall thickness)  
R
40 1/2” (419mm) Rigid  
36-3/4” (324mm) Flex  
K
L
Corner Facing Wall Width  
Framed Chase Ceiling  
36” (914mm) Rigid  
30” (762mm) Rigid  
32” (813mm) Flex  
M
Vent Centerline Height  
26” (660mm) Flex  
Please refer to Exterior Vent Terminations for  
additional guidelines on vent locations.  
***Important: Framing height requires consideration of the hearth  
depth. Dimension H = H + the thickness of installed hearth.  
28  
August 2008 Product Specications Book  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Gas Fireplaces  
P33 Gas Fireplace  
Framing and Finishing  
1) Determine the total thickness of facing material (e.g. drywall plus  
ceramic tiles) to allow the nished surface to be ush with the front  
of the unit. Total facing thickness can vary from 1/2” (13mm) to 1-¼”  
(32mm) thick.  
2) Frame in the enclosure for the unit with framing material.  
3) For exterior walls, insulate the enclosure to the same degree as  
the rest of the house, apply vapor barrier and drywall, as per local  
installation codes. (Do not insulate the replace itself.)  
4) The top of the unit must not be closer than 30” (762mm) to the  
ceiling.  
5) Combustible material may be brought up to the top and  
sides of the unit and be covered with ceramic tiles, bricks,  
rock or other suitable combustible finishing materials.  
Note: The unit does not have to be completely enclosed in a  
chase. The clearance on top of the unit is 0” to the standoffs  
so combustible building materials can be laid directly on top  
of the standoffs. You must maintain proper clearances from  
the vent to combustible materials (See Below).  
Vent Clearances  
Horizontal - Top  
Horizontal - Side  
Horizontal - Bottom  
Vertical - Flex  
Clearance Dimension  
2-1/2” (64mm)  
1-1/2” (38mm)  
1-1/2” (38mm)  
1-1/2” (38mm)  
Vertical - Rigid  
1-1/4” (32mm)  
WARNING  
Failure to maintain required clearances is a major cause of  
chimney related res. Installation of this replace must comply  
with these clearances.  
Combustible Mantels  
Because of the extreme heat this replace emits, the mantel  
clearances are critical. Combustible mantel clearances from top of  
the louvers are shown in the diagram below. Mantel may be installed  
anywhere in the shaded area or higher.  
6) Use metal studs for framing where the minimum clearance from  
the vent to combustible material cannot be maintained.  
Mantel Clearances  
0
12 10  
8
6
4
2
Clearance Requirements  
Drywall  
12"(305mm)  
7-1/2"(191mm)  
3-1/2"(89mm)  
D
C
B
C
D
A
F
0
Top of  
Unit  
B
A
B
Side View  
Mantel Clearances  
A
B
C
D
Front  
29” (737mm)  
11” (279mm)  
9” (229mm)  
7” (178mm)  
Note: If desired a non-combustible mantel may be installed at a  
lower height.  
E
Note: Ensure the paint that is used on the mantel and the facing  
is “heat resistant” or the paint may discolour.  
Clearance:  
Dimension  
7” (178mm)  
Measured From:  
Minimum (Additional on this page)  
Side of installed front  
Mantel Leg Clearances  
Combustible mantel leg clearances as per diagram below:  
A: Mantel Height  
B: Sidewall  
7-1/2” (191mm)  
30” (762mm)  
12” (305mm)  
48” (1219mm)  
36” (914mm)  
Clearances are from the nished edge of the unit or an installed front.  
C: Ceiling  
Top of installed unit  
D: Mantel Depth  
E: Alcove Width  
F: Alcove Depth  
Maximum (Additional on this page)  
Sidewall to Sidewall (Minimum)  
Front to back wall (Maximum)  
Top of Hearth must not be higher than the base of the rebox.  
Maximum  
1-1/2” projection at 2”  
minimum clearance.  
30  
August 2008 Product Specications Book  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Gas Fireplaces  
P33 Gas Fireplace  
Clearance Requirements with  
Contemporary Faceplate  
Combustible Mantels with  
Contemporary Faceplate  
Because of the extreme heat this replace emits, the mantel  
clearances are critical. Combustible mantel clearances from top of  
the louvers are shown in the diagram below. Mantel may be installed  
anywhere in the shaded area or higher.  
C
C
B
Close to Ceiling  
*Note: All measurements are from the top/side  
of the unit, not optional front.  
Clearance:  
Dimension  
Measured  
From:  
A: *Front Floor Clearance  
(min.)  
1" (25mm)  
Underside of  
Unit  
B: *Sidewall  
7-1/2" (241mm)  
Side of Unit  
C: *Ceiling  
(room and/or alcove)  
30" (889mm)  
48" (1219mm)  
Top of Unit  
D: Alcove Width  
Sidewall to  
Sidewall  
Mantel Leg Clearances with  
Contemporary Faceplate  
Combustible mantel leg clearances from side of unit as per diagram  
below:  
(Minimum)  
Front to  
Back Wall  
(Maximum)  
E: Alcove Depth  
36" (914mm)  
Clearances are from the nished edge of the unit or an installed front.  
Flue Clearances to  
Combustibles  
Horizontal - Top  
2-1/2"  
1-1/2"  
1-1/2"  
1-1/2"  
1-1/4"  
Horiztonal - Side  
Horiztonal - Bottom  
Vertical (Flex Vent)  
Vertical (Rigid)  
Top View  
WARNING  
Failure to maintain required clearances is a major cause of chimney related res.  
Installation of this replace must comply with these clearances  
Please note: Due to ongoing product development, product appearance and specications  
are subject to change without notice.  
WARNING  
Fire hazard is an extreme risk  
if these clearances (air space) to combustible materials are not  
adhered to. It is of greatest importance that this replace and vent  
system be installed only in accordance with these instructions.  
Caution Requirements  
The top, back and sides of the replace are dened by  
standoffs. The metal ends of the standoff may NOT be  
recessed into combustible construction.  
August 2008 Product Specications Book  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Gas Fireplaces  
P33 Gas Fireplace  
FPI Direct Vent System (Flex)  
Horizontal Terminations Only  
Important  
When installing Cabinet Mantels: the wall thimble must be secured  
rst and venting must be attached to unit before sliding into nal  
position.  
This venting system, in combination with the P33 Direct Vent Gas  
Fireplace, have been tested and listed as a direct vent heater system by  
Warnock Hersey. The location of the termination cap must conform to the  
requirements in the Vent Terminal Locations diagram, see manual.  
FPI Direct Vent (Flex) System Termination Kits include all the parts  
needed to install the P33 using a exible vent.  
Snorkel Terminations  
Snorkel Terminations:  
FPI Kit #  
Length Contains:  
For installations requiring a vertical rise on the exterior of the building,  
14-inch and 36-inch tall Snorkel Terminations and the Riser Vents are  
available. Follow the same installation procedures as used for standard  
Horizontal Termination. NEVER install the snorkel upside down.  
#946-513  
2 Feet  
4 Feet  
10 Feet  
1) 6-5/8” exible liner (Kit length)  
2) 4” exible liner (Kit length)  
3) spring spacers (3)  
4) thimble (2)  
5) AstroCap termination cap (1)  
6) screws (12)  
#946-515  
#946-516  
Notes:  
Riser Vent  
Termination  
7) tube of Mill Pac (1)  
8) plated screws (8)  
9) S.S. screws #8 x 1-1/2” drill point, (4)  
Dura-Vent  
Snorkel  
1) Liner sections should be continuous without any joints or seams.  
2) Only Flex pipe purchased from Regency may be used for Flex  
installations.  
Min. 12"*  
(305mm)  
3) Horizontal sections must be supported every 3 feet.  
Min. 6-1/4"*  
(159mm)  
Below Grade Snorkel Installation (Dura-Vent Only)  
Wall Thimble (2 pc)  
If the Snorkel Termination must be installed below grade, i.e. basement  
application, proper drainage must be provided to prevent water from  
entering the Snorkel Termination. Refer to Rigid Pipe Installation  
instructions for details. Do not attempt to enclose the Snorkel within the  
wall, or any other type of enclosure.  
AstroCapTM  
Termination Cap  
(Part# 946-523/P)  
4" (102mm)  
dia. flue pipe  
spring  
spacer  
6-7/8"  
(173mm)  
dia. Flue pipe  
Dura-Vent  
Snorkel  
Alternate Horizontal  
Termination Caps  
Window  
Well  
Adequate  
drainage  
Gravel  
If required by the external termination location the listed  
alternate termination caps may be used.  
32  
August 2008 Product Specications Book  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Gas Fireplaces  
P33 Gas Fireplace  
Rigid Pipe Venting  
Horizontal or Vertical Terminations  
2
4
8
14  
0
6
10  
12  
40  
38  
36  
34  
32  
30  
28  
Alternate Horizontal  
Termination Caps  
26  
24  
22  
20  
18  
16  
14  
12  
10  
If required by the external termination location the listed  
alternate termination caps may be used. (Refer to Page 11)  
Venting Arrangements - Vertical  
Terminations  
Rigid Pipe System  
(Propane & Natural Gas)  
The P33 is approved for a maximum 40 ft. straight vertical, with Rigid  
Pipe vent systems for Propane and Natural Gas.  
The lightly shaded area,  
, in the diagram shows allowable venting  
congurations with a maximum two 45° elbows.  
The darker shaded area,  
congurations using one 45° and one 90° elbow.  
, in the diagram shows allowable venting  
8
6
Vent must be supported at offsets.  
Horizontal sections must be supported every 3 feet.  
Firestops are required at each floor level and whenever  
passing through a wall.  
Maintain clearances to combustible materials.  
Minimum of 1’ pipe section between elbows.  
4
2
0
Note: Must use optional rigid pipe adapter when using Rigid Pipe  
(Part # 510-994).  
* Unit must be raised by 1” when using Contemporary Faceplate  
Max. 10’ (3m)(centerline to centerline)  
Minimum 12” (305mm)  
August 2008 Product Specications Book  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Gas Fireplaces  
P33 Gas Fireplace  
Vertical Venting with Two (2) 90° Elbows  
Vertical Venting with Three (3) 90°  
Elbows - Initial vertical section.  
Two 45° elbows = One 90° elbow  
- Initial vertical section.  
Two 45° elbows = One 90° elbow  
Option  
A)  
V
H
V+ V1  
2’ Min.  
3’ Min.  
4’ Min.  
5’ Min.  
6’ Min.  
Maximum total pipe: length, of  
all sections, must not exceed  
30 feet.  
Total horizontal sections must  
not exceed 8 feet.  
Option  
A)  
V
H + H1  
3’ Max.  
4’ Max.  
5’ Max.  
6’ Max.  
7’ Max.  
8’ Max.  
V+ V1  
4’ Min.  
6’ Min.  
7’ Min.  
8’ Min.  
9’ Min.  
10’ Min.  
Maximum total pipe: length, of  
all sections, must not exceed  
30 feet.  
Total horizontal sections must  
not exceed 8 feet.  
1’ Min.  
2’ Min.  
3’ Min.  
4’ Min.  
5’ Min.  
4’ Max.  
5’ Max.  
6’ Max.  
7’ Max.  
8’ Max.  
2’ Min.  
3’ Min.  
4’ Min.  
5’ Min.  
6’ Min.  
7’ Min.  
B)  
B)  
C)  
C)  
Minimum of 1 foot between  
90° elbows is required.  
Minimum of 1 foot between  
90° elbows is required.  
D)  
D)  
E)  
E)  
F)  
Vertical Venting with Two (2) 90° Elbows  
- Initial horizontal section.  
Vertical Venting with Three (3) 90°  
Elbows - Initial horizontal section.  
Two 45° elbows = One 90° elbow  
Two 45° elbows = One 90° elbow  
Option  
A)  
H + H1  
2’ Max.  
3’ Max.  
4’ Max.  
5’ Max.  
6’ Max.  
V
Maximum total pipe: length, of  
all sections, must not exceed  
30 feet.  
2’ Min.  
3’ Min.  
4’ Min.  
5’ Min.  
6’ Min.  
Option  
A)  
H
V
H + H1  
3’ Max.  
4’ Max.  
5’ Max.  
6’ Max.  
7’ Max.  
V+ V1 Maximum total pipe:  
Total horizontal sections must  
not exceed 6 feet.  
Minimum of 1 foot between  
90° elbows is required.  
B)  
length, of all sections,  
1’ Max.  
2’ Max.  
3’ Max.  
4’ Max.  
5’ Max.  
1’ Min.  
2’ Min.  
3’ Min.  
4’ Min.  
5’ Min.  
3’ Min.  
5’ Min.  
7’ Min.  
9’ Min.  
11’ Min.  
must not exceed 30  
feet.  
C)  
B)  
Total horizontal sections  
must not exceed 7  
feet.  
D)  
E)  
C)  
Minimum of 1 foot  
between 90° elbows  
is required.  
D)  
E)  
34  
August 2008 Product Specications Book  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Gas Fireplaces  
P33 Gas Fireplace  
Maintain clearances to combustibles.  
Venting Arrangements - Horizontal  
Terminations  
Horizontal vent must be supported every 3 feet.  
Firestops are required at each oor level and whenever passing  
through a wall.  
This lightly shaded area of the diagram shows allowable combinations  
of vertical runs with horizontal terminations, using one 45° and one  
90° elbow (two 45ºelbows equal one 90° elbow).  
A vent guard may be required as per local codes, refer to Exterior  
Vent Termination Locations.  
Note: Must use optional rigid pipe adapter (Part # 510-994) when  
using Rigid Pipe.  
Note: FPIDirectVentSystem(Flex)isonlyapprovedforhorizontal  
terminations.  
* Unit must be raised by 1” when using  
Contemporary Faceplate  
Please refer to Exterior Vent Terminations for  
additional guidelines on vent locations.  
August 2008 Product Specications Book  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Gas Fireplaces  
P33 Gas Fireplace  
Horizontal Venting with Two (2) 90°  
Horizontal Venting with Three (3) 90°  
Elbows - Initial vertical section.  
Two 45° elbows = One 90° elbow  
Elbows - Initial vertical section.  
Two 45° elbows = One 90° elbow  
Option  
A)  
V
H+ H1  
3’ Max.  
4’ Max.  
5’ Max.  
6’ Max.  
7’ Max.  
8’ Max.  
Maximum total pipe: length, of  
all sections, must not exceed  
30 feet.  
Total horizontal sections must  
not exceed 8 feet.  
Option  
A)  
V
H
V+ V1  
3’ Min.  
4’ Min.  
6’ Min.  
8’ Min.  
10’ Min.  
12’ Min.  
H + H1  
4’ Max.  
5’ Max.  
6’ Max.  
7’ Max.  
8’ Max.  
9’ Max.  
Maximum total  
pipe: length, of  
all sections, must  
not exceed 30  
feet.  
Total horizontal  
sections must not  
exceed 8 feet.  
Minimum of 1  
foot between  
90° elbows is  
required.  
1’ Min.  
2’ Min.  
3’ Min.  
4’ Min.  
5’ Min.  
6’ Min.  
2’ Min.  
3’ Min.  
4’ Min.  
5’ Min.  
6’ Min.  
7’ Min.  
1’ Max.  
2’ Max.  
3’ Max.  
4’ Max.  
5’ Max.  
6’ Max.  
B)  
B)  
C)  
C)  
Minimum of 1 foot between  
90° elbows is required.  
D)  
D)  
E)  
E)  
F)  
F)  
Horizontal Venting with Two (2) 90°  
Elbows - Initial horizontal section.  
Two 45° elbows = One 90° elbow  
Horizontal Venting with Three (3) 90°  
Elbows - Initial horizontal section.  
Two 45° elbows = One 90° elbow  
Option  
A)  
H
V
H + H1  
3’ Max.  
5’ Max.  
6’ Max.  
7’ Max.  
8’ Max.  
Maximum total pipe: length, of  
all sections, must not exceed  
30 feet.  
1’ Max.  
2’ Max.  
3’ Max.  
4’ Max.  
5’ Max.  
1’ Min.  
2’ Min.  
4’ Min.  
6’ Min.  
8’ Min.  
Option  
A)  
H
V
H + H1 + H2 Maximum total pipe:  
Total horizontal sections must  
not exceed 8 feet.  
Minimum of 1 foot between  
90° elbows is required.  
B)  
length, of all sections,  
C)  
1’ Max.  
2’ Max.  
3’ Max.  
4’ Max.  
5’ Max.  
6’ Max.  
1’ Min.  
3’ Min.  
5’ Min.  
7’ Min.  
9’ Min.  
11’ Min.  
3’ Max.  
5’ Max.  
6’ Max.  
7’ Max.  
8’ Max.  
9’ Max.  
must not exceed 30  
feet.  
D)  
B)  
Total horizontal sections  
must not exceed 7  
feet.  
E)  
C)  
Minimum of 1 foot  
between 90° elbows  
is required.  
D)  
E)  
F)  
36  
August 2008 Product Specications Book  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Gas Fireplaces  
P33 Gas Fireplace  
Vertical termination with co-linear  
Required Parts:  
Part #  
ex system  
Description  
946-529  
Co-linear DV Vertical Termination Cap  
3” Flex - 35 ft.  
The appliance must not be connected to a chimney ue  
serving a separate solid fuel burning appliance.  
948-305  
946-563  
Coaxial to Co-linear Adapter Kit  
Rigid Pipe Adapter  
510-994  
Masonry chimneys may take various contours which the exible liner  
will accommodate. However, keep the exible liner as straight as  
possible, avoid unnecessary bending.  
58dva-E45  
45º Elbow  
Alternate Approved Caps  
The Air Intake pipe must be attached to the inlet air collar of the  
termination cap.  
46dva-VC  
46dva-VCH  
46dva-GK  
Vertical Termination Cap  
High Wind Cap  
This appliance is designed to be attached to two 3” (76mm) co-linear  
aluminium ex running the full length of the chimney. See the Venting  
Arrangements for minimum and maximum heights.  
3” Co-linear Adapter with ashing  
Co-linear DV  
Vertical Termination  
Cap # 946-529  
30  
A maximum  
of two certified  
joiner kits  
may be used  
per length.  
Flex Liner  
#948-305  
35 ft (11m)  
Exhaust  
Flue  
Outer  
Pipe  
with Kit#  
946-563  
Air Intake  
Pipe Length  
Co-Linea  
Flex  
Rigid Pipe Adapter  
Adapter  
# 510-994  
with Kit#  
946-563  
45o Elbow  
Horizontal Distance (Feet)  
Inner Pipe  
Adapter  
with Kit#  
946-563  
The shaded area in the diagrams show the allowable vertical  
terminations.  
Please refer to Exterior Vent Terminations for  
additional guidelines on vent locations.  
August 2008 Product Specications Book  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Radio Shack Clock 63 1088 User Guide
RCA DVD Player RTD315W User Guide
RCA DVD VCR Combo DRC6355N User Guide
RCA Flat Panel Television J20L743 User Guide
Remington Electric Shaver DA 57 User Guide
Rockford Fosgate Speaker R1S410 User Guide
Runco Home Theater Screen VX 3000D User Guide
Saint Gobain Vidros Heat Pump PFD1 User Guide
Samsung Flat Panel Television UN75F6300 User Guide
Seagate Computer Drive ST98823AS User Guide