Raypak Water Heater HD101 THRU 2342B User Guide

M o d e ls H D 10 1 t h r u 2 3 4 2 B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
9
5
8
6
7
4
2
11  
10  
1
1. Light weight Refract ory Panels  
Multi-piece ceramic fiber panels enhance combus-  
tion while minimizing heat retention.  
5. On-Board Diagnost ic Cent er  
8. Cent ral Point Wiring  
Factory mounted standard equipment (302-2342).  
Gives relevant service feedback as well as possible  
solutions to clear the fault. All in plain English, no  
cryptic codes to decipher. The control stores up to  
16 fault codes in its history file for the service tech-  
nician to review.  
Factory-made wire harnesses connect all electrical  
components to an easy-to-troubleshoot circuit  
board with multi-pin connectors.  
2. Fully-enclosed Headers  
Temperature sensors and lead wires/capillaries are  
protected from weather, vandalism, and accidental  
damage during installation and service.  
9. Heat Exchanger Tubes  
Time-proven copper finned tubes and optional  
cupro-nickel tubes stand up to even the harshest  
water conditions.  
6. St at us Display Light s  
Up to 12 high-intensity LED lights, visible up-front,  
indicate the operating status of the boiler.  
3. Flue Connect ion  
Top or back outlet flue connections offer greater  
installation flexibility.  
10. Burners  
Special stainless steel alloy pre-mix burners pro-  
vide clean, robust combustion and meet all low  
NOx regulations.  
7. Const ruct ion  
4. Air Filt er  
The cabinet and all internal parts are made from  
galvanized, aluminized or stainless steel. The exte-  
rior is protected by textured powder-coat paint,  
ideally designed for indoor or outdoor installations.  
An easily-cleaned combustion air filter protects the  
burners from airborne particles including flying  
insects.  
11. HSI Access Panel  
A small panel provides access to both the hot sur-  
face igniter and the flame sensor to aid inspection  
and service.  
On-Board Diagnostic Center  
Raypaks Hi Delta (302 thru 2342) comes equipped with a microprocessor-controlled diagnostic control center that displays its  
information on a 2x20 character LCD display in plain English. This control monitors system safeties, ignition faults and system  
status, while storing up to 16 reported faults. Raypaks diagnostic center also monitors the fault outputs of the Fenwal ignition  
control. The Fenwals flash codes are converted into real English fault codes that anyone can understand. The control is also  
equipped with a SPDT dry contact relay output that is switched anytime a safety fault occurs. This can be used for a heater alarm  
or a BMS safety interface.  
Diagnostic Information  
Example Diagnostic Fault Report  
Safety Faults  
Ignition Control Faults  
Low Air  
Condensate Drain  
Manual High Limit  
Auto High Limit  
Low Water Cut-off  
Vent Pressure  
Water Flow Sw Fault  
Check Boiler Pump, Purge Air, Replace Flow Switch  
Flame- No CFH  
Ignition Lockout  
Low HSI Current  
Low 24VAC  
High Gas Pressure  
Low Gas Pressure  
Controller Alarm  
Flow Switch  
Internal Control Fault  
Blower Switch  
Factory Option  
External Interlock  
Cold Water Run  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vertical Venting  
Category I (Type B)  
Sidew all Vent  
Category III  
Op tio n s  
SureRackTM Kit  
See Cat. 1000.16 for  
complete SureRack Details  
The perfect solution for todays most space challenged equipment rooms.  
Stacking two Hi Delta 2342 boilers provides over 4.6MMBTU in just over  
26 square feet plus clearances. All components (except pumps and PRV’s)  
are contained inside the cabinet, so there won’t be any gas valves or fans  
hanging off the unit. The units remain fully serviceable even while racked.  
For models 302 thru 2342  
No Vent Offset Required  
Small Footprint  
Fits in Low-Ceiling Room  
Heavy-Duty Construction  
Easy Assembly  
All Hardware Included  
Still Allows for Complete Servicing  
98% High-efficiency Hi Delta w ith optional CHX  
condensing heating system  
Hi Delta with CHX achieves unequaled 98% thermal efficiency at full fire. It combines  
the reliability of the Hi Delta boiler with an optional CHX heat exchanger which pre-  
vents condensation in the heaters primary combustion chamber. Self contained sec-  
ondary heat exchanger can be inspected and maintained without disturbing the vent  
or plumbing connections. The result is an ultra high efficiency heater that lasts.  
(See Cat. 1000.17)  
For models 402 thru 2002  
Indoor/Outdoor installation  
Top or rear CHX mounting options  
Fully certified vent systems available  
Up to 4.0MMBTU if used with the  
SureRack racking system  
Fully-engineered rack systems simplify  
jobsite installation and set-up  
Straight tube heat exchanger outlasts  
other designs and facilitates scale-  
free operation – ideal for DHW  
applications  
Flex GasTM  
Dual-fuel boilers and w ater heaters  
With its patented, CSA-certified rapid fuel switchover system, the Hi Delta FlexGas  
is an ideal solution for interruptible-fuel applications (natural/propane gas).  
(See Cat. #1000.20)  
For models 302 thru 2342  
Changeover takes less than one minute  
Changerover can be accomplished  
while firing: simply turn the key!  
Factory-installed and tested system  
CSA-Certified  
No mechanical components to remove  
or replace  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cold Water Start  
Cold Water Run  
C o ld W a te r So lu tio n Op tio n s  
Cold Water Start  
It is commonly known that prolonged internal condensation will dramatically shorten the life of standard boilers and water heaters. While  
Raypak boilers and water heaters can operate without harmful condensation at lower inlet water temperatures than the competition,  
there are still applications that require reliable protection against harmful condensation caused by frequent, extended, cold water start-  
ups. Raypaks Cold Water Start protection system utilizes a proportional three-way valve to bypass water from the boiler outlet to the  
inlet during start-up, when the system return water temperature is below the minimum acceptable level.  
Cold Water Run  
For the same reason stated for Cold Water Starts, it is even more important to provide protection against condensation from cold inlet  
water on systems where the return water temperature to the boiler will always be below the acceptable minimum. Raypaks Cold Water  
Run system utilizes a variable-speed pump to inject just the right amount of water from the main system loop into the boiler to maintain  
the optimum inlet temperature. This approach allows the full capacity of the boiler to be utilized to meet the system load, while at the  
same time continuously maintaining the optimum inlet water temperature to prevent condensation.  
(See Cat. #1000.19)  
Simple Serviceability  
Control Options  
Raypaks easy-to-understand user interface, including on-  
board diagnostics and LED operating status lights, tells  
the technician all he needs to know. All service/repair  
components are readily accessible from the front for max-  
imum installation flexibility.  
Raypaks array of leading edge controllers offer features such as:  
sequence-control of up to 40 boilers; PID technology; optimized  
approach to outdoor reset; LonWorks or BMS interfacing; freeze pro-  
tection and other energy-saving functions. Raypaks controllers have  
been specially designed to maximize the performance of its leading-  
edge Hi Delta boilers.  
1
2
3
TempTracker  
Designed to sequence multiple boilers up to  
four total stages, whether its one to four  
on/off boilers, two two-stage boilers, or one  
boiler with up to four stages. It is available  
factory-mounted or loose. (See Cat. 5100.22)  
4
5
RayTemp  
Demand-based set-point control maximizes  
energy savings in domestic hot water appli-  
cations (See Cat. 5100.18)  
Y-200 Boiler Sequencer  
Provides additional functionality for multi-  
ple-boiler installations. Compatible with  
LonWorks® Building Management Systems  
(BMS) (See Cat. #5100.22)  
9
8
7
6
1 Diagnostic Control Center  
2 Fenwal ignition control  
6 Manual reset high limit  
7 Main power disconnect  
3 Central point wiring board 8 Standby power switch  
4 Transformer  
9 Status lights  
5 Pump delay relay  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Recovery Rates (GPH)  
Temperature Rise (°F)  
Hi Delta MBTUH  
Model Input  
10  
20  
510  
765  
1015  
1276  
30  
340  
510  
677  
850  
40  
50  
60  
170  
70  
80  
128  
90  
100  
110  
93  
120  
85  
130  
78  
140  
150  
HD101 100  
HD151 150  
HD201 199  
HD251 250  
HD301 299  
HD401 399  
1020  
1531  
2031  
2551  
3051  
4024  
3055  
4063  
5091  
6618  
7636  
9164  
10080  
12829  
15578  
18327  
255  
383  
508  
638  
763  
204  
306  
406  
510  
610  
805  
611  
813  
146  
219  
290  
364  
436  
575  
436  
580  
727  
945  
113  
170  
226  
283  
339  
447  
339  
451  
566  
735  
848  
102  
153  
203  
255  
305  
402  
305  
406  
509  
662  
764  
916  
73  
109  
145  
182  
218  
287  
218  
290  
364  
473  
545  
655  
720  
916  
68  
102  
135  
170  
203  
268  
204  
271  
339  
441  
509  
611  
672  
855  
255  
338  
425  
509  
671  
509  
677  
848  
1103  
1273 1091  
1527 1309  
1680 1440  
2138 1833  
2596 2225  
3055 2618  
3392 2908  
3513 3011  
3971 3404  
191  
254  
319  
381  
503  
382  
508  
636  
827  
955  
139  
185  
232  
277  
366  
278  
369  
463  
602  
694  
833  
916  
128  
169  
213  
254  
335  
255  
339  
424  
552  
636  
764  
840  
118  
156  
196  
235  
310  
235  
313  
392  
509  
587  
705  
775  
987  
1526 1017  
2012 1341 1006  
1527 1018 764  
2031 1354 1016  
302B  
402B  
502B  
652B  
752B  
902B  
992B  
300  
399  
500  
650  
750  
900  
990  
2545 1697 1273 1018  
3309 2206 1655 1324  
3818 2545 1909 1527  
4582 3055 2291 1833  
5040 3360 2520 2016  
6415 4276 3207 2566  
7789 5193 3895 3116  
9164 6109 4582 3665  
1145 1018  
1260 1120 1008  
1262B 1260  
1532B 1530  
1802B 1800  
2002B 1999  
2072B 2070  
2342B 2340  
1604 1425 1283 1166 1069  
1947 1731 1558 1416 1298 1198 1113 1039  
2291 2036 1833 1666 1527 1410 1309 1222  
2544 2261 2035 1850 1696 1566 1454 1357  
2635 2342 2108 1916 1756 1621 1505 1405  
2978 2647 2383 2166 1985 1833 1702 1588  
20353 10177 6784 5088 4071  
21076 10538 7025 5269 4215  
23825 11913 7942 5956 4765  
Recovery Rates (GPH)  
Temperature Rise (°F)  
Hi Delta MBTUH  
Model Input  
10  
20  
510  
765  
1015  
1276  
30  
340  
510  
677  
850  
40  
50  
60  
70  
80  
90  
100  
110  
93  
120  
85  
130  
78  
140  
150  
HD101 100  
HD151 150  
HD201 199  
HD251 250  
HD301 299  
HD401 399  
1020  
1531  
2031  
2551  
3051  
4071  
3091  
4111  
5152  
6697  
7727  
9273  
10200  
12982  
15764  
18545  
255  
383  
508  
638  
765  
204  
306  
406  
510  
612  
814  
618  
822  
170  
146  
219  
290  
364  
437  
582  
442  
587  
736  
957  
128  
113  
170  
226  
283  
340  
452  
343  
457  
572  
744  
859  
102  
153  
203  
255  
306  
407  
309  
411  
515  
670  
773  
927  
73  
109  
145  
182  
218  
291  
221  
294  
368  
478  
552  
662  
729  
927  
68  
102  
135  
170  
203  
271  
206  
274  
343  
446  
515  
618  
680  
865  
255  
338  
425  
510  
679  
515  
685  
859  
1116  
1288 1104  
1545 1325  
1700 1457  
2164 1855  
2627 2252  
3091 2649  
3433 2942  
3555 3047  
4018 3444  
191  
254  
319  
383  
509  
386  
514  
644  
837  
966  
139  
185  
232  
277  
370  
281  
374  
468  
609  
702  
843  
927  
128  
169  
213  
254  
339  
258  
343  
429  
558  
644  
773  
850  
118  
156  
196  
235  
313  
238  
316  
396  
515  
594  
713  
785  
999  
1531 1020  
2036 1357 1018  
1545 1030 773  
2055 1370 1028  
302B  
402B  
502B  
652B  
752B  
902B  
992B  
300  
399  
500  
650  
750  
900  
990  
2576 1717 1288 1030  
3348 2232 1674 1339  
3864 2576 1932 1545  
4636 3091 2318 1855  
5100 3400 2550 2040  
6491 4327 3245 2596  
7882 5255 3941 3153  
9273 6182 4636 3709  
1159 1030  
1275 1133 1020  
1623 1442 1298 1180 1082  
1970 1752 1576 1433 1314 1213 1126 1051  
2318 2061 1855 1686 1545 1427 1325 1236  
2574 2288 2060 1872 1716 1584 1471 1373  
2666 2370 2133 1939 1777 1641 1523 1422  
3014 2679 2411 2192 2009 1855 1722 1607  
1262B 1260  
1532B 1530  
1802B 1800  
2002B 1999  
2072B 2070  
2342B 2340  
20596 10298 6865 5149 4119  
21327 10664 7109 5332 4265  
24109 12055 8036 6027 4822  
Recovery Rates (GPH)  
Temperature Rise (°F)  
Hi Delta MBTUH  
Model Input  
10  
20  
30  
40  
50  
60  
527  
701  
879  
70  
80  
395  
526  
659  
857  
989  
90  
100  
110  
120  
264  
351  
439  
571  
659  
791  
870  
130  
140  
150  
302BE 300  
402BE 399  
502BE 500  
652BE 650  
752BE 750  
902BE 900  
992BE 990  
1262BE 1260  
1532BE 1530  
1802BE 1800  
2002BE 1999  
2072BE 2070  
2342BE 2340  
3164  
4208  
5273  
6855  
7909  
1582 1055  
2104 1403 1052  
791  
633  
842  
452  
601  
753  
979  
352  
468  
586  
762  
879  
316  
421  
527  
685  
791  
949  
288  
383  
479  
623  
719  
863  
949  
243  
324  
406  
527  
608  
730  
803  
226  
301  
377  
490  
565  
678  
746  
949  
211  
281  
352  
457  
527  
633  
696  
886  
2636 1758 1318 1055  
3427 2285 1714 1371  
3955 2636 1977 1582  
4745 3164 2373 1898  
5220 3480 2610 2088  
6644 4429 3322 2657  
8067 5378 4034 3227  
9491 6327 4745 3796  
1142  
1318 1130  
1582 1356  
1740 1491  
2215 1898  
2689 2305  
3164 2712  
3513 3011  
3638 3118  
4113 3525  
9491  
1186 1055  
10440  
13287  
16135  
18982  
1305 1160 1044  
1661 1476 1329 1208 1107 1022  
2017 1793 1613 1467 1345 1241 1152 1076  
2373 2109 1898 1726 1582 1460 1356 1265  
2635 2342 2108 1916 1757 1622 1506 1405  
2729 2425 2183 1984 1819 1679 1559 1455  
3085 2742 2468 2243 2056 1898 1763 1645  
21080 10540 7027 5270 4216  
21829 10915 7276 5457 4366  
24676 12338 8225 6169 4935  
NOTE: 98% efficiency available with condensing heat exchanger. (See Specialty Models on pg. 4.)  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
MBTUH Output*  
Type H  
Dimensions (in.)  
Ref.  
Dwg.  
pg. 5  
Operating  
Weight Amps  
(lbs.)  
Hi Delta  
Model  
MBTUH  
Input*  
A
Width  
G
H
K
T
Type WH  
85%  
B
W
NPT NPT Flue Ø Ø  
(Cat. I) 87% (Cat. II)  
HD101 100  
HD151 150  
HD201 199  
HD251 250  
HD301 299  
HD401 399  
85  
128  
169  
213  
254  
335  
252  
335  
420  
546  
630  
756  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
261  
347  
435  
566  
653  
85  
128  
18-9/16 9-1/4  
21-7/8 10-7/8 3/4 1-1/2  
3/4 1-1/2  
4
4
5
5
5
6
5
6
6
8
8
8
4
4
4
4
4
4
6
6
6
6
6
6
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
18  
18-1/2  
22  
27-1/4  
30-3/4  
36  
150  
175  
200  
225  
250  
300  
380  
445  
545  
590  
675  
740  
900  
1010  
1225  
1350  
4.7  
4.7  
4.7  
4.7  
4.7  
4.7  
6
6
6
6
6
169 25-1/16 12-1/2 3/4 1-1/2  
213 28-5/16 14-1/8 3/4 1-1/2  
254 31-9/16 15-3/4 3/4 1-1/2  
1
2
339 38-1/16  
19  
18  
3/4 1-1/2  
302B  
402B  
502B  
652B  
752B  
902B  
992B  
300  
399  
500  
650  
750  
900  
990  
255  
339  
425  
553  
638  
765  
842  
36  
43  
50  
3/4  
2
2
2
2
2
2
21-1/2 3/4  
25 1-1/4  
60-1/2 30-1/4 1-1/4  
67-1/2 33-3/4 1-1/4  
783  
861  
78  
39  
1-1/4  
7
832  
57-1/8 28-9/16  
2
2
2
2
2
2
2
2-1/2 10 10 16-13/16  
2-1/2 12 10 20-9/16  
2-1/2 12 10 24-3/8  
2-1/2 14 10 28-1/8  
2-1/2 14 10 31-15/16 1450  
2-1/2 14 10 31-15/16 1450  
2-1/2 16 10 35-11/16 1520  
<12  
<12  
<12  
<12  
<12  
<12  
<12  
1262B 1260  
1532B 1530  
1802B 1800  
2002Bª 1999  
2072B 2070  
2342B 2340  
1058  
1285  
1512  
1679  
1739  
1966  
1096  
1331  
1566  
1739  
1801  
2036  
1071 68-1/2 34-1/4  
1301 79-7/8 39-15/16  
1530 91-1/8 45-9/16  
1699 102-1/2 51-1/4  
1760 102-1/2 51-1/4  
1989 113-7/8 56-15/16  
3
* Ratings for models HD101-HD401 for natural or propane gas and for elevations up to 2,000 ft. above sea level . For higher elevations, consult the factory.  
* Ratings for models 302B-2342B for natural or propane gas and for elevations up to 4,500 ft. above sea level . For higher elevations, consult the factory.  
Add “E” Suffix to model number.  
Current draw is for heater only. (Supply breaker must have a delayed trip.)  
ª Natural gas only. Not available for propane.  
Water Hardness  
Medium  
Indoor  
Minimum  
Outdoor  
Boiler  
Side  
Hi Delta  
Model  
Soft  
Amps  
Hard  
Service  
Minimum  
Service  
HP  
HP  
Amps  
HP  
Amps  
Floor*  
Rear  
Water side  
Other side  
Top  
0”  
1”  
12”  
1”  
1”  
Open  
2”  
0”  
24”  
24”  
24”  
1”  
0”  
0”  
12”  
36”  
36”  
24”  
36”  
36”  
HD101 1/8  
HD151 1/8  
HD201 1/8  
HD251 1/8  
HD301 1/8  
HD401 1/8  
302B  
402B  
502B  
652B  
752B  
902B  
992B  
1.1  
1.1  
1.1  
1.1  
1.1  
1.1  
1.3  
1.3  
1.3  
1.3  
1.3  
5.7  
6
6
7
11  
11  
11  
14  
1/8  
1/8  
1/8  
1/8  
1/8  
1/8  
1/4  
1/4  
1/4  
1/4  
1/2  
1/2  
1/2  
3/4  
1
1.3  
1.3  
1.3  
1.3  
1.3  
1.3  
5.7  
5.7  
5.7  
5.7  
7
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/2  
1/2  
1/2  
1/2  
3/4  
3/4  
3/4  
1
5.7  
5.7  
5.7  
5.7  
5.7  
5.7  
7
7
7
7
11  
11  
11  
14  
14  
15  
15  
15  
15  
Unobstructed Unobstructed  
Front  
Vent  
24”  
2”  
Open  
N/A  
24”  
N/A  
* Do not install on carpeting.  
1/8  
1/8  
1/8  
1/8  
1/8  
1/4  
1/4  
California Bill AB-1953  
Raypak is the first manufacturer to comply with California bill  
AB-1953. This is new legislation, mandating the maximum lead  
content of brass to be less than .25% of the wetted surfaces.This  
legislation goes into effect January 1, 2010.  
7
7
1262B 1/4  
1532B 1/2  
1802B 3/4  
2002B 3/4  
2072B 3/4  
11  
14  
14  
15  
15  
15  
1
1
1-1/2  
1-1/2  
1-1/2  
1-1/2  
1-1/2  
1-1/2  
1-1/2  
2342B  
1
Note: Current draw (Amps) is for pump only.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
DRAWING 1 - MODELS HD101-HD401  
K FLUE CONNECTION DIA.  
B
OPTIONAL PUMP  
8-7/8  
H WATER IN  
LOW VOLTAGE CONNECTIONS  
SEE  
PUMP  
CHART  
T COMBUSTION AIR DIA.  
G GAS CONNECTION  
A
H WATER OUT  
18-1/4  
POWE  
R
ON  
C
A
L
L
F
O
R
H
E
A
T
B
URNE  
R
®
FIRING  
SERVICE  
REQUIRE  
D
S
S
OFF  
P
/
N
9
0
1
9
2
7
R
E
V
1
26-3/8  
19-7/16  
1-1/4  
16-9/16  
4-9/16  
8-1/2  
5-1/16  
13-1/2  
4-15/16  
19-3/8  
22-1/8  
23-1/2  
26  
MANUAL SHUT-OFF  
& DIAGNOSTIC LIGHTS  
LINE VOLTAGE CONNECTIONS  
DRAWING 2 - MODELS 302B-902B  
A
B
K FLUE  
OUTDOOR  
VENT TERMINAL  
CONNECTION DIA.  
T COMBUSTION AIR  
25  
INLET DIA.  
T OPTIONAL COMBUSTION AIR  
INLET DIA.  
11-5/8  
7-1/8  
ON-BOARD  
DIAGNOSTIC  
CENTER  
G GAS CONNECTION  
H WATER OUT  
K OPTIONAL  
REAR FLUE  
G OPTIONAL GAS CONNECTION  
INLET DIA.  
CONNECTION DIA.  
17-3/4  
POWER  
SAFETY  
IGNITION  
FLOW  
ON  
C
A
L
L
F
O
R
HEA  
T
STAGE  
STAGE  
1
2
BLOWER  
1
STANDBY  
P
R
O
U
D
L
Y
M
A
D
E
IN  
A
M
E
R
IC  
A
6
OPTIONAL  
PUMP COVER  
P
/
N
9
0
1
8
9
1
34-1/8  
31-1/4  
H WATER IN  
28-1/2  
25-1/2  
28-1/2  
VIEW PORT  
18-5/8  
12-1/8  
PRV  
1-3/4  
7-1/2  
OPTIONAL PUMP  
6-1/2  
7
3-1/4  
2-1/2  
T & P GAUGE  
W
MANUAL SHUT-OFF  
& DIAGNOSTIC LIGHTS  
DRAWING 3 - MODELS 992B-2342B  
A
B
K FLUE  
OUTDOOR  
VENT TERMINAL  
CONNECTION DIA.  
ON-BOARD  
DIAGNOSTIC  
CENTER  
T COMBUSTION AIR  
32-5/8  
INLET DIA.  
T OPTIONAL COMBUSTION AIR  
INLET DIA.  
9-1/2  
G GAS CONNECTION  
10-7/8  
K OPTIONAL  
REAR FLUE  
CONNECTION DIA.  
G OPTIONAL GAS CONNECTION  
INLET DIA.  
POWER  
SAFETY  
17-3/4  
ON  
C
A
L
L
F
O
R
IGNITION  
HEA  
T
STAGE  
STAGE  
STAGE  
1
2
3
FLOW  
BLOWER  
BLOWER  
1
2
8-5/8  
HWATER OUT  
STANDBY  
P
R
O
U
D
L
Y
M
A
D
E
IN  
A
M
E
R
IC  
A
OPTIONAL  
PUMP COVER  
41-1/4  
HWATER IN  
35-3/4  
32-7/8  
30-3/8  
20-3/8  
32-7/8  
VIEW PORT  
12-7/8  
PRV  
2-1/2  
8-1/4  
OPTIONAL PUMP  
2-1/2  
T & P GAUGE  
3-1/4  
W
13-1/4  
6-3/4  
MANUAL SHUT-OFF  
& DIAGNOSTIC LIGHTS  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Flow Rates  
Pressure Drops  
20°F T 30°F T  
Hi Delta  
Model  
10°F T  
40°F T  
Minimum Flow  
P Ft T °F  
Maximum Flow  
P Ft T °F  
P Ft  
P Ft  
P Ft  
P Ft  
GPM  
GPM  
GPM  
GPM  
GPM  
GPM  
HD101  
HD151  
HD201  
HD251  
HD301  
HD401  
302B  
402B  
502B  
652B  
752B  
13  
13  
13  
13  
13  
17  
20  
20  
21  
27  
32  
38  
42  
53  
64  
76  
84  
87  
98  
0.7  
0.7  
3.3  
0.7  
0.7  
13  
20  
26  
33  
39  
40  
25  
34  
40  
40  
40  
40  
40  
40  
40  
40  
40  
40  
40  
44  
44  
44  
44  
44  
44  
90  
90  
90  
90  
90  
90  
132  
132  
132  
132  
132  
132  
132  
8.8  
8.8  
8.9  
9.2  
9.4  
4
6
8
10  
12  
15  
6
17  
25  
33  
44  
1.2  
2.9  
5.2  
9.2  
Less than Minimum Flow  
0.9  
13  
17  
21  
25  
34  
25  
34  
42  
55  
63  
76  
83  
106  
129  
0.7  
1.3  
2.1  
3.1  
5.6  
<1.0  
1.4  
2.3  
4.1  
5.7  
8.3  
5.2  
9.6  
15.7  
14  
17  
22  
1.3  
2.5  
13  
17  
0.7  
1.4  
Exceeds  
Maximum Flow  
1.4  
9.8  
9.8  
Less than Minimum Flow  
<1.0  
<1.0  
<1.0  
1.1  
1.5  
2.2  
1.3  
2.4  
4.0  
6.0  
50  
67  
84  
3.1  
5.5  
9.1  
10.0  
10.4  
10.8  
11.3  
11.7  
13.1  
14.8  
16.5  
18.3  
19.0  
19.0  
21.4  
7
9
22  
28  
36  
42  
50  
55  
71  
86  
101  
112  
116  
131  
<1.0  
1.1  
1.8  
2.6  
3.8  
2.3  
4.3  
7.1  
10.7  
13.8  
14.8  
21.1  
21  
27  
32  
38  
42  
53  
64  
76  
84  
87  
98  
<1.0  
1.1  
1.5  
2.2  
1.3  
2.4  
4.0  
6.0  
7.9  
8.5  
12.1  
12  
14  
17  
13  
16  
19  
23  
25  
26  
30  
902B  
992B  
1262B  
1532B  
1802B  
2002B  
2072B  
2342B  
7.9  
8.5  
12.1  
Exceeds Maximum Flow  
Water Hardness  
Medium  
Hi Delta  
Model  
Soft  
Hard  
T °F  
P Ft  
T °F  
P Ft  
GPM  
SHL* T °F  
P Ft  
GPM  
SHL*  
GPM  
SHL*  
MTS  
HD101  
HD151  
HD201  
HD251  
HD301  
HD401  
302B  
402B  
502B  
652B  
752B  
9
20  
20  
20  
20  
20  
20  
40  
40  
40  
40  
42  
51  
60  
72  
86  
101  
112  
116  
132  
1.8  
1.8  
1.9  
1.9  
1.9  
2.0  
2.0  
2.0  
2.1  
2.2  
2.6  
3.9  
2.7  
4.4  
7.1  
10.7  
13.9  
14.8  
21.4  
3.8  
3.8  
3.9  
3.9  
3.9  
4.0  
5.1  
5.1  
5.2  
5.3  
6.0  
8.7  
5.2  
7
26  
26  
26  
26  
26  
26  
52  
52  
52  
55  
63  
76  
83  
106  
132  
132  
132  
132  
132  
3.0  
3.1  
3.2  
3.2  
3.2  
3.3  
3.3  
3.4  
3.5  
4.1  
5.7  
8.4  
5.2  
6.3  
6.3  
6.4  
6.5  
6.5  
6.6  
8.3  
8.4  
8.6  
4
6
8
9
11  
15  
6
8
9
12  
14  
17  
13  
16  
20  
23  
26  
27  
30  
45  
45  
45  
45  
45  
45  
90  
90  
90  
90  
90  
90  
132  
132  
132  
132  
132  
132  
132  
9.2  
9.2  
9.4  
9.6  
9.8  
18.0  
18.1  
18.2  
18.5  
18.7  
19.1  
23.7  
23.8  
24.2  
24.7  
25.1  
25.5  
23.6  
25.3  
27.0  
28.7  
29.5  
29.5  
31.8  
1-1/2”  
1-1/2”  
1-1/2”  
1-1/2”  
1-1/2”  
1-1/2”  
2”  
2”  
2”  
2”  
2”  
13  
17  
21  
26  
34  
13  
17  
21  
28  
30  
30  
28  
30  
30  
30  
30  
30  
30  
10  
13  
16  
20  
26  
10  
13  
16  
20  
20  
20  
20  
20  
20  
23  
26  
27  
30  
10.3  
9.8  
10.0  
10.4  
10.8  
11.3  
11.7  
13.1  
14.8  
16.5  
18.3  
19.0  
19.0  
21.4  
9.7  
12.8  
18.6  
9.7  
16.6  
27.0  
28.7  
29.5  
29.5  
31.8  
902B  
992B  
2”  
2-1/2”  
2-1/2”  
2-1/2”  
2-1/2”  
2-1/2”  
2-1/2”  
2-1/2”  
1262B  
1532B  
1802B  
2002B  
2072B  
2342B  
7.9  
9.6  
11.9  
17.1  
21.6  
23.1  
31.8  
16.5  
18.3  
19.0  
19.0  
21.4  
Flow Rates  
Pressure Drops  
20°F T 30°F T  
Hi Delta  
Model  
10°F T  
40°F T  
Minimum Flow  
P Ft T °F  
Maximum Flow  
P Ft T °F  
P Ft  
P Ft  
P Ft  
P Ft  
GPM  
GPM  
GPM  
GPM  
GPM  
GPM  
Less than Minimum Flow  
<1.0  
302BE  
402BE  
502BE  
652BE  
752BE  
902BE  
992BE  
1262BE  
1532BE  
1802BE  
2002BE  
2072BE  
20  
20  
22  
28  
33  
39  
43  
55  
67  
78  
87  
90  
<1.0  
<1.0  
<1.0  
1.1  
1.6  
2.3  
1.4  
2.6  
4.3  
6.5  
26  
35  
40  
40  
40  
40  
40  
40  
40  
40  
40  
40  
40  
90  
90  
90  
90  
90  
9.8  
10.0  
10.4  
10.8  
11.3  
11.7  
13.1  
14.8  
16.5  
18.3  
19.0  
19.0  
22.6  
6
8
52  
69  
87  
3.3  
6.0  
9.7  
26  
35  
44  
57  
65  
78  
86  
110  
132  
<1.0  
1.5  
2.5  
4.4  
6.1  
8.9  
5.6  
10.3  
16.5  
23  
29  
38  
44  
52  
57  
73  
89  
104  
116  
120  
136  
10  
13  
15  
17  
13  
17  
20  
24  
26  
27  
30  
1.1  
2.0  
22  
28  
33  
39  
43  
55  
67  
78  
87  
90  
102  
<1.0  
1.1  
1.6  
2.3  
1.4  
2.6  
4.3  
6.5  
8.5  
9.1  
12.9  
2.8  
4.1  
90  
132  
132  
132  
132  
132  
132  
136  
2.5  
4.6  
7.6  
11.5  
14.8  
15.8  
22.6  
8.5  
9.1  
12.9  
Exceeds Maximum Flow  
2342BE 102  
NOTES: 98% efficiency available with condensing heat exchanger. (See Specialty Models on pg. 4.) Minimum flow rates in closed systems may be reduced to a flow rate consistent with a 40°F T.  
Maximum flow rates are limited by maximum acceptable velocity through the heat exchanger tubes and may be increased by 10% for closed heating systems. Pressure drop would increase 21%.  
*SHL = Calculated at 100 feet effective pipe length.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Boilers (Type H)  
Water Heaters (Type WH)  
HD101-HD401 302B-902B 992B-2342B HD101-HD401 302B-902B 992B-2342B  
ASME, National Board Registered, 160 PSI H Stamp  
HLW Stamp  
Copper  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
Heat Exchanger Tubes  
Headers  
Cupro Nickel  
Bronze  
Cast Iron  
Pressure Relief Valve  
Temperature & Pressure Gauge  
Pump – 120V, Single-Phase  
30, 45, 60, 75, 125 & 150 PSI Available ꢀ  
120V Power Supply  
Pump Time Delay  
With 120V/24V Transformer  
Single Phase  
Diagnostic Display Central  
Temperature Controller  
16-Event Memory  
B-20: On/Off, Mechanical  
B-28: On/Off, Digital  
B-6: 2-Stage, Mechanical  
B-26–B-27: 2-Stage, Digital  
B-21–B-23: 4-Stage, Digital  
B-24: 2-Stage, Raytemp (Digital)  
B-25: 4-Stage, Raytemp (Digital)  
Y-200 Series, Digital  
N/A  
N/A  
N/A  
N/A  
Hot Surface Ignition System  
3-try  
1-try  
N/A  
N/A  
High Gas Pressure Switch  
Low Gas Pressure Switch  
Blocked Vent and Air Pressure Switches  
High Limit Switch  
Manual Reset, Fixed  
Manual Reset, Adjustable  
Automatic Reset, Adjustable  
N/A  
(1)  
N/A  
N/A  
N/A  
Low Water Cut-Off, 24V  
Flow Switch  
With manual reset and test button  
Firing Mode  
On/Off (H4, WH1)  
2-Stage (H3, WH3)  
3-Stage (H8, WH8)  
4-Stage (H9, WH9)  
N/A  
N/A  
(2)  
(3)  
N/A  
N/A  
(4)  
(5)  
N/A  
N/A  
(2)  
(3)  
N/A  
N/A  
(4)  
(5)  
4” WC Supply Pressure  
Natural Gas Only  
(6)  
(6)  
TruSeal Direct Vent System  
Air Filter, Room Air  
Air Filter, Ducted Outside Air  
Efficiency  
(98% available; See Specialty Models)  
84% (Category I)  
85% (Category I)  
87% (Category II)  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
Combustible Floor Rated  
Alarm System  
(7)  
(8)  
(7)  
(8)  
Vent Terminal  
Outdoor and Through-the-Wall  
Right-Hand Water Connections  
CSD-1/GE GAP Control System  
Low NOx Compliance  
Cold Water Start  
N/A  
N/A  
Meets all current requirements  
Cold water protection systems  
Cold water protection systems  
N/A  
N/A  
N/A  
N/A  
Cold Water Run  
Notes:  
1 Standard on on/off boilers (H4); Optional on all others  
= Standard = Optional  
6 Option but not available on Model 2002B  
2 Standard on Models 302B and 402B; Optional on Models 502B-902B 7 Not applicable for Models 302B and 402B; Optional for Models 502B-902B  
3 Optional on Models 302B and 402B; Standard on Models 502B-902B 8 Standard on Models 992B-2002B; Models 2072B and 2342B  
4 Standard on 992B; Optional on 1262B-2342B  
5 Not available on Model 992B; Standard on Models 1262B-2342B  
require site testing and have different emissions requirements  
(Consult factory)  
Raypak, Inc. • 2151 Eastman Ave., Oxnard, CA 93030 • phone: (805) 278-5300 • fax: (800) 872-9725 • www.raypak.com  
Cat. No. 1100.12C Effective 11-15-09 Replaces: 07-01-09  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Quinny Air Compressor 65040 AB User Guide
RCA Flat Panel Television D40W20 User Guide
Renesas Computer Hardware M32186T2 PTC User Guide
RIDGID Sander R2611 User Guide
Rowenta Electric Shaver 037116 20 04 RF3210 9210 User Guide
Samsung Printer 3560 User Guide
Samsung Projection Television Projection Television User Guide
Samsung Refrigerator SR 40NMA User Guide
Sanyo Microwave Oven EM G475AS User Guide
Schneider Electric Computer Hardware 890USE19600 Version 10 User Guide