Raypak Swimming Pool Heater P 1826 User Guide

INSTALLATION & OPERATING  
INSTRUCTIONS  
Raytherm™  
Commercial  
Swimming  
Pool  
Heater  
Models P-926 to P-1826  
& P-2100 to P-4001  
L
W
WARNING: If these instructions are not followed exactly, a fire or explosion may  
result causing property damage, personal injury or death.  
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and  
liquids or other combustible materials in the vicinity of this or any other appliance.  
To do so may result in an explosion or fire.  
WHAT TO DO IF YOU SMELL GAS:  
• Do not try to light any appliance.  
• Do not touch any electrical switch; do not use any phone in your building.  
• Immediately call your gas supplier from a neighbor's phone. Follow the gas  
supplier's instructions.  
• If you cannot reach your gas supplier, call the fire department.  
Installation and service must be performed by a qualified installer, service agency or  
the gas supplier.  
This manual should be maintained in legible condition and kept adjacent to the heater or in another safe place for  
future reference.  
CATALOG NO. 6200.51P  
Effective: 05-24-10  
Replaces: 04-09-07  
P/N 240251 Rev. 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTENTS  
WATER CHEMISTRY  
GENERAL  
2
SPECIFICATIONS  
5
Flow Switch  
18 TROUBLESHOOTING  
18 WARRANTY  
35  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNINGS  
Pay Attention to These Terms  
Indicates the presence of immediate hazards which will cause severe person-  
DANGER:  
WARNING:  
CAUTION:  
NOTE:  
al injury, death or substantial property damage if ignored.  
Indicates the presence of hazards or unsafe practices which could cause  
severe personal injury, death or substantial property damage if ignored.  
Indicates the presence of hazards or unsafe practices which could cause  
minor personal injury or product or property damage if ignored.  
Indicates special instructions on installation, operation, or maintenance which  
are important but not related to personal injury hazards.  
DANGER: Make sure the gas on which the heater  
will operate is the same type as that specified on the  
heater rating plate.  
CAUTION: Operation of this heater in low-  
temperature systems requires special piping.  
Harmful internal condensation will occur if the inlet  
water temperature does not exceed 105°F. Warranty  
claims will be denied when condensation occurs.  
WARNING: Should overheating occur or the gas  
supply valve fail to shut, do not turn off or disconnect  
the electrical supply to the heater. Instead, shut off  
the gas supply at a location external to the heater.  
CAUTION: If this heater is to be installed above  
radiation level, it must be provided with a low water  
cut-off device at the time of heater installation.  
WARNING - CALIFORNIA PROPOSITION  
65: This product contains chemicals known to the  
State of California to cause cancer, birth defects or  
other reproductive harm.  
CAUTION: If this heater is to be installed in a  
negative or positive pressure equipment room, there  
are special installation requirements. Consult factory  
for details.  
WARNING: To minimize the possibility of improper  
operation, serious personal injury, fire, or damage to  
the heater:  
Always keep the area around the heater free of  
combustible materials, gasoline, and other flam-  
mable liquids and vapors.  
Heater should never be covered or have any  
blockage to the flow of fresh air to the heater.  
WARNING: Do not use this heater if any part has  
been under water. Immediately call a qualified  
service technician to inspect the heater and to  
replace any part of the control system and any gas  
control which has been under water.  
WARNING: Risk of electrical shock. More than one  
disconnect switch may be required to deenergize the  
equipment before servicing.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
RECEIVING EQUIPMENT INSTALLATION  
On receipt of the equipment, visually check for exter- These instructions are intended for the use of qualified  
nal damage to the carton or the shipping crate. If the personnel only, specifically trained and experienced in  
carton or shipping crate is damaged, make a note on the installation of this type of heating equipment and  
the Bill of Lading and report the damage to the Carrier related system components. Installation and service  
immediately. Remove the heater from the carton or personnel may be required by some states to be  
shipping crate. Do NOT use the shipping base crate as licensed. If your state is such, be sure your contractor  
an installation base.  
bears the appropriate license. Persons not qualified  
shall not attempt to fix this equipment nor attempt  
repairs according to these instructions.  
On occasion, we ship some items loose. Be sure that  
you receive the number of packages indicated on the  
Bill of Lading. When ordering parts, you must specify  
Model and Serial Number of heater. When ordering  
under warranty conditions, you must also specify date  
of installation.  
WARNING: Improper installation, adjustment,  
alteration, service or maintenance may damage the  
equipment, create  
a
hazard resulting in  
asphyxiation, explosion or fire, and will void the  
warranty.  
Raypak recommends that this manual be reviewed  
thoroughly before installing your Raypak Pool Heater.  
If there are any questions which this manual does not  
answer, please contact the factory or your local  
Raypak representative.  
Code Requirements  
The heater should not be located in an area where  
possible water leakage will result in damage to the  
area adjacent to the appliance or to the structure.  
When such locations cannot be avoided, it is recom-  
mended that a suitable drain pan, adequately drained,  
be installed under the appliance. The pan must not  
restrict combustion air flow.  
Claims for shortages and damages must be filed with  
carrier by consignee. Permission to return goods must  
be factory authorized and are subject to a stocking  
charge.  
Purchased parts are subject to replacement only  
under the manufacturer's warranty. Debits for defec-  
tive replacement parts will not be accepted and will be  
replaced in kind only per our standard warranties.  
Installation must be in accordance with local codes, or,  
in the absence of local codes, with the latest editions  
of the National Fuel Gas Code, ANSI Z223.1/NFPA 54,  
and National Electrical Code, ANSI/NFPA 70.  
GENERAL  
Base Installation  
SPECIFICATIONS  
Do NOT use the shipping base crate as an installation  
base. Heater must be mounted on a level base, such  
as cement slab, cement blocks or other non-com-  
bustible surface. An optional non-combustible base is  
available for Indoor Models 962 through 1826. An  
alternative method for providing a base for com-  
bustible floors as illustrated below. Heaters may not be  
installed on carpeting.  
Models 962, 1125, 1223, 1336, 1468, 1631, 1826 &  
2100 through 4001 are specifically designed for indoor  
installation ONLY. Models 926, 1083, 1178, 1287,  
1414, 1571 & 1758 are specifically designed for out-  
door installation ONLY. All heaters are standard with  
electronic ignition for both natural and propane appli-  
cations. Heaters require 120V power supply. Control  
circuits operate at 24V, supplied by an internal 120V to  
24V transformer.  
These heaters are design certified and tested under  
the requirements of ANSI Z21.56 / CSA 4.7 American  
National Standard for Gas-Fired Pool Heaters. Rated  
inputs suitable for up to 2000 feet elevation. For eleva-  
tions above 2000 feet, reduce input 4% for each 1000  
feet above sea level, as high elevation reduces com-  
bustion performance.  
Fig. 1: Alternate Mounting Base  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Clearances  
All Heaters  
For clearances from combustible surfaces, see Table  
A below. We require a minimal vertical clearance of  
three feet between the upper surface of the flue outlet  
to a noncombustible material.  
Outdoor Heaters  
Indoor Heaters  
(926–1758)  
Heater  
Side  
Clearance  
(Inches)  
Heater  
Side  
Clearance  
(Inches)  
Top  
Back  
24  
24  
24  
24  
6
Top  
24  
24  
24  
24  
Fig. 2: Minimum Distance from Openings  
Back  
The point from where the flue products exit the heater  
must be a minimum of four (4) feet below, four (4) feet  
horizontally from or one (1) foot above any door, win-  
dow or gravity inlet to a building. The top surface of the  
heater shall be at least three (3) feet above any forced  
air inlet, or intake ducts located within ten (10 ) feet  
horizontally.  
Right Side  
Left Side  
Vent*  
Right Side  
Left Side  
*Vent includes factory supplied drafthood and does not include field  
supplied vent systems above the drafthood. On Models 2100-4001  
drafthood is built into heater.  
For servicing provide a front clearance as shown below:  
Model 926/962-758/1826 - 24"  
Model 2100-4001 - 48"  
High Wind Conditions  
(Outdoor Units Only)  
Table A: Minimum Clearances from Combustible  
Construction  
In areas where high winds are frequent, it may be nec-  
essary to locate the heater a minimum of 3' from high  
vertical walls, or install a wind break so the heater is  
not in direct wind current.  
For servicing, provide at least 24" in front of the heater  
on Models 926-1826 & 48" in front of the heater on  
Models 2100-4001 for burner tray removal, and at  
least 18" on the right side of the heater to inspect and  
delime the heat exchanger.  
Indoor Heaters  
The design is also certified for indoor installation when  
equipped with approved drafthood. Locate heater as  
close as practical to a chimney or gas vent.  
Outdoor Heaters (Models 926-1758)  
These heaters are design certified for outdoor installa-  
tion, when equipped with the approved top designated  
for outdoor use. Heaters must not be installed under  
an overhang of less than three (3) feet from the top of  
the heater. Three (3) sides must be open in the area  
under the overhang. Roof water drainage must be  
diverted away from heaters installed under overhangs  
with the use of gutters.  
Combustion Air  
(Indoor Units Only)  
The heater must have both combustion and ventilation  
air. Openings must not be obstructed. Minimum  
requirements are as follows:  
CAUTION: Combustion air must not be  
contaminated by corrosive chemical fumes which  
can damage the heater and void the warranty.  
WARNING: The heater shall not be located in an  
area where water sprinklers, or other devices, may  
cause water to spray through the cabinet louvers  
and into the heater. This could cause heavy internal  
rusting or damage some electrical components, and  
this would void the warranty.  
1. Free combustion air 1 sq. in. per 1000 BTU input  
within 12" of the floor.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2. Free ventilation air 1 sq. in. per 1000 BTU input must have a minimum of 1/4 inch per foot rise and  
within 12" of the ceiling level.  
should be supported at not more than five foot inter-  
vals. Plumbers' tape, criss-crossed, will serve to space  
both horizontal and vertical piping.  
NOTE: If the room the heater is installed in is  
located against an outside wall and air openings  
communicate directly with the outdoors, the  
openings may be 1/4 the size specified above (ANSI  
Z223.1/NFPA 54, latest edition)  
Gas vents supported only by the flashing and extend-  
ing above the roof more than five feet should be  
securely guyed or braced to withstand snow and wind  
loads. We recommend use of insulated vent pipe  
spacer through the roofs and walls.  
Venting Connections  
For protection against rain or blockage by snow, the  
vent pipe must terminate with a vent cap which com-  
plies with the local codes or, in the absence of such  
codes, to the latest edition of the National Fuel Gas  
Code, ANSI Z223.1/NFPA 54.  
Drafthood (Indoor) Models 962-1826  
Locate and assemble as shown in Fig. 3. Secure with  
screws supplied in envelope in carton.  
The discharge opening must be a minimum of two feet  
vertically from the roof surface and at least two feet  
higher than any part of the building within ten feet.  
Vent stack shall be at least five feet in vertical height  
above the drafthood outlet. The vent cap location shall  
have a minimum clearance of 4 feet horizontally from,  
and in no case above or below, unless a 4-foot hori-  
zontal distance is maintained, from electric meters,  
gas meters regulators and relief equipment.  
The weight of the vent stack or chimney must not rest  
on heater drafthood. Support must be provided in  
compliance with applicable codes. The heater top and  
draft hood must be readily removable for maintenance  
and inspection. Vent pipe should be adequately sup-  
ported to maintain proper clearances from  
combustible construction.  
Type "B" double wall or equivalent vent pipe is recom-  
mended. However, single wall metal vent pipe may be  
used as specified in the latest edition of the National  
Fuel Gas Code ANSI Z223.1/NFPA 54.  
Fig. 3: Indoor Draft Hood  
Models 2100-4001 have built-in drafthoods that must  
be properly vented to the outside.  
10' OR LESS  
VENT CAP  
Vent Piping  
2' MIN  
2' MIN  
WARNING: Indoor heater requires a drafthood that  
must be connected to a vent pipe and properly  
vented to the outside. Failure to follow this procedure  
can cause fire or fatal carbon monoxide poisoning.  
5' MIN  
VENT PIPE  
Vent piping the same size or larger than the draft hood  
outlet is recommended, however, when the total vent  
height is at least ten (10) feet (drafthood relief opening  
to vent terminal), the vent pipe size may be reduced  
as specified in the National Fuel Gas Code, ANSI  
Z223.1/NFPA 54 - latest edition. Avoid long horizontal  
runs of vent pipe and too many elbows. If installation  
requires horizontal or non-vertical runs, the vent pipe  
DRAFT HOOD  
HEATER  
Fig. 4: Venting Clearances  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
At the time of removal of an existing heater, the follow-  
ing steps shall be followed with each appliance  
remaining connected to the common venting system  
placed in operation, while the other appliances remain-  
ing connected to the common venting system are not  
in operation.  
Gas Supply Connections  
Gas piping must have a sediment trap ahead of the  
heater gas controls, and a manual shut-off valve locat-  
ed outside the heater jacket. All gas piping should be  
tested after installation in accordance with local codes.  
(a) Seal any unused openings in the common venting  
system.  
(b) Visually inspect the venting system for proper size  
and horizontal pitch and determine there is no  
blockage or restriction, leakage, corrosion and  
other deficiencies which could cause an unsafe  
condition.  
MANUAL  
SHUT-OFF  
VALVE  
(c) Insofar as is practical, close all building doors and  
windows and all doors between the space in which  
the appliances remaining connected to the com-  
mon venting system are located and other spaces  
of the building. Turn on clothes dryers and any  
appliance not connected to the common venting  
system. Turn on any exhaust fans, such as range  
hoods and bathroom exhausts, so they will oper-  
ate at maximum speed. Do not operate a summer  
exhaust fan. Close fireplace dampers.  
SEDIMENT  
TRAP  
Fig. 5: Gas Piping  
CAUTION: The heater and its manual shut-off  
valve must be disconnected from the gas supply  
during any pressure testing of that system at test  
pressures in excess of 1/2 psig (3.45 KPA).  
Dissipate test pressure in the gas supply line before  
reconnecting the heater and its manual shut-off  
valve to gas supply line. FAILURE TO FOLLOW  
THIS PROCEDURE MAY DAMAGE THE GAS  
VALVE. OVER PRESSURIZED GAS VALVES ARE  
NOT COVERED BY WARRANTY. The heater and its  
gas connections shall be leak tested before placing  
the appliance in operation. Use soapy water for leak  
test. DO NOT use open flame.  
(d) Place in operation the appliance being inspected.  
Follow the lighting instructions. Adjust thermostat  
so appliance will operate continuously.  
(e) Test for spillage at the drafthood relief opening  
after 5 minutes of main burner operation. Use the  
flame of a match or candle, or smoke from a ciga-  
rette, cigar or pipe.  
CAUTION: Do not use Teflon tape on gas line pipe  
thread. A pipe compound rated for use with natural  
and propane gases is recommended. Apply  
sparingly only on male pipe ends, leaving the two  
end threads bare.  
(f) After it has been determined that each appliance  
remaining connected to the common venting sys-  
tem properly vents when tested as outlined above,  
return doors, windows, exhaust fans, fireplace  
dampers and any other gas burning appliance to  
their previous conditions of use.  
A minimum of 7 in. WC and a maximum of 10.5 in. WC  
upstream pressure under load, and no load conditions  
must be provided for natural gas or a minimum of 11  
in. WC and a maximum of 13 in. WC for propane gas.  
(g) Any improper operation of the common venting  
system should be corrected so the installation  
conforms with the latest edition of the National  
Fuel Gas Code, ANSI Z223.1/NFPA 54. When re-  
sizing any portion of the common venting system,  
the common venting system should be re-sized to  
approach the minimum size as determined using  
the appropriate tables in the National Fuel Gas  
Code, ANSI Z223.1/ NFPA 54.  
Gas Pressure Regulator  
The gas pressure regulator is preset and sealed at 4  
in. WC for natural gas, and 11 in. WC for propane gas.  
Between the gas valve and the burners is a 1/8" pipe  
plug. The pressure at this point, taken with a manome-  
ter, should be about 3.7 in. WC natural gas and 10.5  
in. WC propane gas. If an adjustment is needed,  
remove seal and turn adjustment screw clockwise  
, to increase pressure or counter-clockwise  
For special venting applications that require reduced  
vent sizes and through the wall venting, the optional D  
Series Power Vent can be used. Consult the factory or  
your local Raypak representative.  
, to decrease pressure.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Gas Code. Under NO circumstances shall bleed lines  
terminate in the gas utilization equipment flue or  
exhaust system.  
MANOMETER  
MANUAL  
SHUTOFF  
VALVE  
GAS PRESSURE  
TEST UPSTREAM  
GAS PRESSURE  
TEST AT GAS  
VALVE  
GAS PRESSURE TEST  
AT HEATER  
Fig. 6: Gas Pressure Test Points  
Venting of Diaphragm Gas  
Components  
Bleed Line  
Connection  
Heaters with gas train components that have  
diaphragms in their construction are supplied with a  
bleed line connection that must be connected to the  
outside atmosphere as required by the National Fuel  
Fig. 7: Bleed Line Connection  
1”  
1-1/4”  
1-1/2”  
2”  
2-1/2”  
3”  
4”  
Model  
No.  
N
P
N
P
N
P
N
P
N
P
N
P
N
P
926/962  
1083/1125  
1178/1223  
1287/1336  
1414/1468  
1571/1631  
1758/1826  
2100  
15  
10  
20  
15  
45  
35  
25  
25  
20  
15  
15  
10  
45  
35  
25  
20  
15  
15  
10  
10  
110 150 360 400  
80  
60  
55  
45  
35  
30  
25  
15  
10  
120 300 300  
85  
75  
65  
50  
40  
30  
20  
15  
10  
5
220 200  
180 170 325 560  
150 165 300 500  
20  
125 250 400  
100 100 225 340  
80  
55  
35  
30  
20  
75  
55  
40  
30  
25  
175 260  
135 160 400 600  
2500  
3001  
85  
45  
35  
120 250 500  
3500  
80  
65  
200 400 600  
160 300 400  
4001  
3
Natural Gas, 1000 BTU/FT .60 Specific Gravity @ 0.5 in. WC Pressure Drop  
3
Propane Gas, 2500 BTU/FT 1.53 Specific Gravity @ 0.6 in. WC Pressure Drop  
Table B: Maximum Equivalent Pipe Length  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
the time clock may be used for this purpose with  
instructions not to override this sequence manually.  
See wiring diagram section for electrical hookup loca-  
tion of the fireman switch in the electrical circuit.  
Water Connections  
Location  
The heater requires water flow and positive pressure  
to fire and operate properly. It must therefore be  
installed downstream of the discharge side of the filter  
pump. A typical installation is plumbed as follows:  
NOTE: (Models 926-1223): If piping is used into the  
heater, this piping (copper) must be anchored or  
screwed into the flange (metal) if operating  
pressures above 30 PSI are encountered.  
1. The inlet side of the filter is plumbed directly to the  
discharge side of the filter pump;  
CONTROLS  
2. The outlet side of the filter is then plumbed to the  
inlet of the heater; and  
Flow Switch  
3. The outlet of the heater is plumbed to the return  
line to the pool or spa. The pump, filter and heater  
are thus plumbed in series.  
This dual purpose control shuts off the boiler in the  
case of a pump failure or low water condition. It is  
mounted and wired in series to the main gas valve.  
Standard on all models.  
Heater must be located so that any water leaks will not  
damage the structure of adjacent area. High tempera-  
ture plastic pipe (CPVC) may be connected directly  
into the heater Models 926-1223, if local codes permit  
and if controls operate the pump for at least fifteen  
minutes after the heater is turned off.  
NOTE: Flow switch will not operate if flow is less  
than:  
Models 926-1223  
Models 1287-1826  
Models 2100-4001  
60 gpm  
85 gpm  
180 gpm  
CAUTION (Models 926-1223): NEVER install PVC  
directly into heater. Four feet of copper or high  
temperature pipe and two elbows are required  
between the heater and the PVC connections. See  
Fig. 8 below.  
Fig. 9: Flow Switch  
Fig. 8: Plumbing  
When local codes permit the use of less than four feet  
high temperature piping or two elbows, provisions  
should be made to always shut the heater off a mini-  
mum of 15 minutes prior to pump shut down in order  
to carry away residual heat and prevent damage to the  
low temperature piping. A fireman switch included in  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Water Pressure Switch  
Unitherm Governor Operation  
On Models 926-1223 built with a Unitherm Governor The patented Unitherm Governor (UG) is a thermosta-  
(UG), a water pressure switch is provided in the heater tic mixing valve specifically designed to maintain  
to shut down the gas valves in the event the water sup- constant heater internal temperature between 105°  
ply to the heater is interrupted. It is very important to and 115°F despite continually changing flow rates from  
verify that the switch electrically opens and shuts off the filter and changing pool temperatures. This narrow  
the gas valve when water flow to the heater is inter- range is needed to prevent damaging condensation on  
rupted.  
the burners which will occur if the heater runs for any  
length of time below 105°F. It is also needed to inhibit  
Otherwise, rapid and severe damage to the heater will scale formation in the tubes by maintaining tempera-  
likely occur. (The water pressure switch should be tures well below accelerated scaling temperatures.  
checked and adjusted for proper operation by a quali-  
fied service person at the time of installation and The Unitherm Governor is an available option on mod-  
periodically checked thereafter. Refer to pressure els 926 through 1223. Where installed, it is built into  
switch servicing instructions in this manual).  
the inlet/outlet header. The larger sizes, models 1287  
through 4001, do not have a UG option. Instead, they  
have an externally mounted bypass pump that is  
designed to maintain the water entering the heater at  
the proper temperature to prevent condensation and  
scale. Thermometers are provided on the inlet and  
outlet to the heater.  
WARNING: Operation of the heater without water  
circulation will cause rapid and severe damage to  
the heater.  
Automatic Chlorinators and  
Chemical Feeders  
Companion Flange  
Connections  
All chemicals must be introduced and completely dilut-  
ed into the pool or spa water before being circulated  
through the heater. Do not place chlorine tablets or  
bromine sticks in the skimmer. High chemical concen-  
trations will result when the pump is not running (eg,  
overnight).  
(Models 926-1223)  
DO NOT use petroleum base assembly fluids (such as  
Petroleum Jelly or Lubricating Oil). If assembly lube is  
required use a silicone base such as Armoral etc.  
The inlet/outlet header flange accepts a 2" copper tube  
as a slip connection directly into the header. The  
flange is also threaded for a 2" NPT copper male  
adapter.  
Chlorinators must feed downstream of the heater and  
have an anti-siphoning device to prevent chemical  
backup into the heater when the pump is shut off.  
NOTE: High chemical concentrates from feeders  
and chlorinators that are out of adjustment will cause  
very rapid corrosion to the heat exchanger in the  
heater. Such damage is not covered under the  
warranty.  
Fig. 10: Companion Flange Connections  
(Models 926–1223)  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Raypak recommends the installation of an air bleed  
vent at a suitable location (usually the highest point in  
the plumbing) to remove air from the piping system.  
These units should be available at your local whole-  
sale supplier. Raypak does not provide this item.  
Pump  
1-1/2" Slip Ball Valve  
2-1/2" Outlet  
CAUTION: Power to the heater should be  
interlocked with the main system pump to make sure  
the heater does not fire without the main system  
pump in operation. Improper flow control can  
damage the heater. Uncontrolled flow (too high) or  
restricted flow (too low) can seriously affect heater  
operation. Follow these instructions to make sure  
your heater is properly installed.  
2-1/2" Inlet  
Fig. 11: Companion Flange Connections  
(Models 1287/1336–1758/1826)  
3" Inlet  
3" Outlet  
2 H.P. Pump  
Models 1287 through 4001 are equipped with an  
external pump and bypass arrangement that blends  
outlet water with the inlet to increase the inlet water  
temperature, thereby reducing the likelihood of con-  
densation forming on the heat exchanger. The pump  
also serves to circulate water through the heater from  
the main system piping.  
2" Slip  
Ball Valve  
Inlet/Outlet  
Header  
To complete the installation of the pool heater, the pool  
thermostat needs to be installed in the main return  
water line. This will ensure that the heater will be ener-  
gized at the right time. If the main water line is too far  
away from the heater and the capillary bulb will not  
reach it, locate the pool thermostat adjacent to the  
main line and run wires back to the heater. Follow the  
instructions listed below to install the poolstat.  
Fig. 12: Companion Flange Connections  
(Models 2100–4001)  
Connection Minimum Maximum  
Model No.  
Size  
gpm  
gpm  
926–1223  
2” FPT  
60  
120  
1287–1826 2-1/2” FPT  
Mounting the Poolstat Control  
with Front-Mounted Loop  
Using Mounting Slots  
Refer to Table D  
2100–4001  
3” FPT  
Table C: Water Connections  
For heater models:  
Loop* Flow Rates  
(gpm)  
Heater Flow  
Model No.  
1287, 1336, 1414, 1468, 1571, 1631, 1758, 1826,  
2100, 2500, 3001, 3500, 4001.  
Rates (gpm)  
1287/1336  
1414/1468  
1571/1631  
1758/1826  
2100  
30–50  
35–55  
85  
85  
NOTE: For more detail on piping, refer to the  
diagrams on pages 15, 16 & 17.  
40–65  
85  
45–70  
85  
1. Remove the poolstat control cover by removing  
the two cover screws at the top. See Fig. 13 & 14.  
50–80  
180  
180  
180  
180  
180  
2500  
60–95  
3001  
75–115  
90–135  
100–150  
3500  
4001  
*Loop is secondary piping to heater from main system.  
Table D: Flow Rates  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3. Remove either the left or right “knock-out” for  
wiring on the poolstat control as shown in Fig. 17.  
Fig. 13: Poolstat Control  
Fig. 17: Remove Knockout  
4. Attach appropriate conduit and connectors to the  
poolstat control.  
5. Attach wires to the poolstat wire terminals. See  
Fig. 18.  
Fig. 14: Control Cover  
2. Lace metal strapping or clamps, (NOT PROVID-  
ED) through the ¾” slots on the cover and fasten  
securely to pipe as shown in Fig. 15 & 16. Do not  
over-tighten clamps.  
Fig. 18: Attach Wires  
6. Install poolstat control to the cover and fasten  
cover screws.  
7. Poolstat should be mounted level as shown in Fig.  
19.  
Fig. 15: Hose Clamp Slots  
Fig. 19: Mount Level  
Fig. 16: Insert Clamps  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Mounting Well into System  
Return Loop Pipe - Front-  
Mounted Loop  
NOTE: For more detail on piping configurations for  
large systems, refer to the diagrams on pages 15, 16  
& 17.  
1. Locate and mark an area on the main system  
return loop pipe where the well is always exposed  
to the water circulating back from the pool. See  
Fig. 20.  
Fig. 22: Installation with Weld O Lets  
NOTE: The drawings and instructions above show  
only one of several acceptable ways of installing the  
dry well into main system loop. The use of saddle  
clamps and “Weld O Lets” (shown in Fig. 22) are  
HEATER  
acceptable.  
instructions.  
Follow  
clamp  
manufacturer’s  
To adjust the temperature:  
1. Both isolation valves must be fully open.  
2. Adjust Bypass Valve "A" 1/2 open and Balancing  
Valve "B" fully open. (See piping configuration  
page 15, 16 & 17)  
Fig. 20: Installation Location  
3. Fire your Raypak pool heater and adjust Bypass  
Valve "A" to obtain a heater inlet temperature  
approximately 105°F. Turning Valve A in the open  
direction will raise the heater inlet temperature and  
closing Valve "A" will lower the heater inlet temper-  
ature.  
2. Shut off water and drain any water from the pipe  
as necessary.  
3. Drill a 23/32" diameter hole (½” NPT) into the pipe  
as shown in Fig. 21.  
CAUTION: The inlet water temperature must be  
kept above 105°F. Changes in system flow or valve  
position may require re-adjustment of the flow  
settings. Check the heater bypass settings after  
making adjustments. Failure to maintain an inlet  
temperature above 105°F may result in damage to  
the heater. Failure to comply with this instruction  
voids the warranty.  
4. If the heater inlet temperature remains less than  
100°F and Valve "A" is fully open, leave Valve "A"  
fully open and throttle Valve "B" until the heater  
inlet temperature rises above 105°F.  
Fig. 21: Drill Hole in Pipe for Dry Well  
4. Using a ½” NPT tap and appropriate handle,  
thread the tap into the pipe.  
5. The resultant heater outlet temperature should be  
in the range of 120-130°F.  
5. Apply pipe dope as necessary to male threads of  
well and insert into threaded hole. Do not over-  
tighten well.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. As the pool temperature rises to the desired tem-  
perature as controlled by the Pool aquastat, small  
adjustments to valves "A" and "B" will be required  
for optimum performance. Heater temperatures  
should be checked regularly to prevent heater  
condensation. The heater inlet temperature can be  
higher than 105°F without heater damage but  
operating at less than 105°F inlet can cause dam-  
age from condensation.  
NOTE: Consult factory if target temperatures  
cannot be achieved.  
Piping Configurations for Raytherm Commercial Pool Heaters  
INTERNAL DIVERTING  
BYPASS SYSTEM (UG)  
Models 0926 thru 1223 with UG  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Piping Configurations for Raytherm Commercial Pool Heaters  
BLENDEDWATERTEMPERATURE  
(THERMOMETERATHEATERINLET)  
T
I
HEATEROUTLETTEMPERATURE  
THERMOMETER  
To  
HEATERTHERMOSTAT  
T
c
RECOMMENDED FIELD INSTALLED  
ISOLATIONVALVESFORSERVICE  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Piping Configurations for Raytherm Commercial Pool Heaters  
Models 2100 thru 4001  
BLENDEDWATERTEMPERATURE  
T
I
(THERMOMETERATHEATERINLET)  
HEATEROUTLETTEMPERATURE  
THERMOMETER  
To  
HEATERTHERMOSTAT  
T
c
RECOMMENDED FIELD INSTALLED  
ISOLATIONVALVESFORSERVICE  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
External Auxiliary Bypass  
Valve (Where Required)  
926-1223 Models Only  
Bypass Valve  
An auxiliary bypass valve should be used when flow  
rates exceed 120 gpm (usually a high performance  
pump size larger than two HP will exceed this flow  
rate). This valve is required to complement the func-  
tion of the automatic bypass valve, particularly when  
starting the heater in winter or early spring when the  
spa or pool temperature is below 55°F. It also serves  
to eliminate needless pressure drop through the  
heater and accompanying reduction in the flow rate to  
the spa jets, etc.  
Open Position  
Closed Position  
From Heater  
To Heater  
Fig. 24: Manual Bypass Valve  
To Pool  
From Filter  
NOTE: To avoid water damage or scalding due to  
valve operation, drain pipe must be connected to  
valve outlet and run to a safe place of discharge.  
Drain pipe must be the same size as the valve  
discharge connection throughout its entire length  
and must pitch downward from the valve. No shut-off  
valve shall be installed between the relief valve and  
the drain line. Valve lever should be tripped at least  
once a year to ensure that waterways are clear.  
Fig. 23: Auxiliary Bypass Valve  
Auxiliary Bypass Valve  
Adjustment  
To set bypass: With clean filter, adjustment is made by  
feeling the inlet and outlet pipes at the heater. Outlet  
pipes should be slightly warmer than inlet and comfort-  
able to the touch. If pipe is hot, close bypass; if cold,  
open bypass.  
Temperature Controls  
High Limits  
NOTE: Do not use a gate valve as an auxiliary  
The pool heater is equipped with two high limits. Both  
high limits, the non-adjustable auto reset high limit and  
adjustable manual reset high limit are attached to the  
outlet side of the in/out header.  
bypass valve on any heaters.  
Models 926-1223  
The heater is also equipped with a manual bypass  
built into the header. This is in addition to the automat-  
ic bypass valve. This may be used with flow rates up  
to 120 gpm and adjusted as below.  
Pool Stat  
The pool heater is equipped with a pool thermostat  
that is attached to the inlet side of the in/out header to  
control the pool temperature.  
NOTE: Sooting or liming caused by improper  
bypass adjustment voids the warranty.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Low Water Cutoff  
Electrical Wiring  
Automatically shuts down burner whenever water  
level drops below probe. A 3 to 5 second time delay  
prevents premature lockout due to temporary condi-  
tions such as power failure or air pockets. Standard on  
Cal Code heaters.  
DANGER - SHOCK HAZARD - Make sure  
electrical power to the heater is disconnected to  
avoid potential serious injury or damage to  
components.  
CAUTION: Label all wires prior to disconnection  
when servicing controls. Wiring errors can cause  
improper and dangerous operation. Verify proper  
operation after servicing.  
NOTE: If it is necessary to replace any of the  
original wiring, it must be replaced with 105° C wire  
or its equivalent.  
Electronic Ignition  
Fig. 25: Low Water Cutoff  
The intermittent ignition device conserves energy by  
automatically extinguishing the pilot when desired  
temperature is reached. When additional heat is need-  
ed, the pilot re-ignites electrically, eliminating the fuel  
costs of maintaining a constant pilot. To ensure safe  
operation, the gas valve cannot open until the pilot  
relights and is confirmed.  
High & Low Gas Pressure Switches  
Pressure switches sense either high or low gas pres-  
sure and automatically shut down burners if abnormal  
pressures exist. Standard on Models 3001-4001.  
Without Lockout  
With Lockout  
Model  
N
P
N
P
926–1826  
Standard  
N/A  
N/A  
N/A  
Optional Standard  
Standard Standard  
2100–4001  
Table E: Lockout Availability  
Heater must be electrically grounded and bonded in  
accordance with local codes, or, in the absence of  
local codes, with the latest edition of the National  
Electrical Code, ANSI/NFPA 70.  
Fig. 26: High/Low Gas Pressure Switch  
Fig. 27: Ignition Module  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Wiring Diagram—Models 926–1223  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Wiring Diagram—Models 1287–1826  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Wiring Diagram—Models 2100–2500  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Wiring Diagram—Models 3001–4001  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Temperature Control  
SERVICING  
The pool water temperature is controlled by the pool  
thermostat. The heater water temperature high limit is  
controlled by the manual reset high limit.  
General Location Of Controls  
Models 926-1826  
Pressure Switch  
Inlet/Outlet  
Header  
Pressure  
Switch  
The pressure switch, or heater actuator on Models  
926-1223 equipped with a Unitherm Governor,  
ensures that the heater operates only when the filter  
pump is in operation. It is factory set at 1.75 PSI for  
deck level installations. When the heater is located  
below the level of the spa or pool, it may be necessary  
to reset the pressure switch to compensate for the no-  
flow static head. If it is necessary to reset the pressure  
switch, we recommend the following procedure.  
Unitherm  
Governor  
Electrical  
Conn.  
Hi-limit  
control/  
Temp. Control  
Main Burner Gas Valve  
Fig. 28: General Location of Controls  
(Models 926-1826)  
Pressure Switch Adjustment  
1. Make sure the pool filter is clean before adjusting  
the switch.  
Models 2100-4001  
2. Set the heater control to the OFF mode.  
Inlet/Outlet  
Header w/Bypass  
Pump  
3. Turn the filter pump on and confirm that the pres-  
sure switch is closed (use a multimeter to check).  
If the pressure switch fails to close, either the  
switch setting is too high or the filter pump is not  
supplying enough pressure.  
4. Turn the heater ON.  
5. Manually turn the pressure adjustment knob clock-  
wise until the heater shuts off. (A flat screw driver  
may be necessary if knob is too tight).  
6. Slowly turn the adjustment knob counter-clock-  
wise until the heater calls for heat again.  
Electrical  
Connection  
Main Burner  
Gas Valve  
7. Turn an additional 1/2 turn counter-clockwise.  
Manual On/Off Valve  
8. While the heater is running, check the adjustment  
by turning the pump off and on several times. The  
burners should shut off immediately when the  
pump is turned off. If it does not, repeat the above  
steps until proper operation is observed.  
Fig. 29: General Location of Controls  
(Models 2100-4001)  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
START-UP  
PROCEDURES  
Before Start-Up  
Burners  
Clean main burners and air louvers of dust, lint and  
debris. Keep heater area clear and free from com-  
bustibles, flammable liquids, and chemicals. Do not  
obstruct the flow of combustion and ventilating air.  
ADJUSTMENT KNOB  
Water  
Fig. 30: Pressure Switch Adjustment Range  
Water must be flowing through the heater.  
Start-Up  
5’ Max  
CAUTION: Propane gas is heavier than air and  
sinks to the ground. Exercise extreme care in lighting  
heater in confined areas.  
5’ Max  
Lighting Instructions  
Fig. 31: Heat Exchanger Height Above/Below Pool  
1. Close all gas valves. Turn off electric power supply  
wait 5 minutes.  
NOTE: If heater is installed outside of the limits  
shown, a flow switch must be used in place of the  
pressure switch when mounted and wired adjacent  
to the heater.  
2. Open manual pilot valve. Turn on electric power,  
pilot is automatically lighted.  
3. Open main gas valve.  
4. Set temperature controls to desired temperature.  
To Shut Down  
Two-Speed Pumps  
In some cases, the flow on the low speed is insufficient  
to operate the heater. This is apparent when the pres-  
sure switch cannot be further adjusted or if the heater  
makes banging noises. In these cases, the pump must  
be run at high speed when heating the water.  
Close all manual gas valves. Turn off electric power.  
CAUTION: Do not operate the heater without the  
function of a properly adjusted pressure switch.  
Pilot Safety  
The heater employs a pilot safety which closes the  
main gas valve within 8/10ths of a second whenever  
the pilot flame is interrupted. Pilot flame is automatical-  
ly lit when the device is powered. Unit performs its own  
safety check and opens the main valve only after the  
pilot is proven to be lit.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
After Start-Up  
INSPECTION  
PROCEDURES  
Pilot System Checkout Procedure  
1. Turn on power to the ignition systems and turn gas  
supply off.  
Burners  
Clean main burners and air louvers of dust, lint and  
debris. Keep heater area clear and free from com-  
bustibles and flammable liquids. Do not obstruct the  
flow of combustion and ventilating air. Make visual  
check of burner and pilot flame. Yellow flame indicates  
clogging of air openings. Lifting or blowing flame indi-  
cates high gas pressure. Low flame indicates low gas  
pressure.  
2. Check ignition module as follows:  
a. Set the thermostat above pool water tempera-  
ture to turn heater on.  
b. Watch for continuous spark at the pilot burner.  
c. Time the spark operation. Time must be with-  
in the lockout timing period (15 or 90  
seconds).  
d. Turn thermostat down to turn off heater and  
wait 60 seconds on lockout models before  
beginning step 3.  
3. Turn on gas supply.  
4. Set thermostat above pool water temperature to  
turn on heater.  
Fig. 32: Main Burner Flame  
5. Systems should start as follows:  
a. Spark will turn on and pilot gas valve will open  
at once. Pilot burner should ignite after gas  
reaches the pilot burner.  
b. Spark ignition should cut off when pilot flame  
is established.  
c. Main gas valve should open and main burner  
should ignite after gas reaches the burner  
port.  
Fig. 33: Pilot Burner Flame  
Feel inlet and outlet pipes. Outlet should be only slight-  
ly warmer than inlet. It should not be hot.  
WARNING: Should overheating occur or the gas  
supply fails to shut off, turn off the manual gas  
control to the appliance.  
CONTROLS  
Check all controls to see that they are operational. To  
check electric safety turn off main burner. Observe  
pilot burner when shutting off pilot gas. Ignition spark  
should go on. Main gas valve will also drop out.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Burner Drawer Removal  
SERVICING  
PROCEDURES  
1. Shut off power and gas supply to the pool heater.  
Disconnect union(s) and pilot tubing, then loosen  
and remove burner-hold down screws.  
Tube Cleaning Procedure  
(Typical)  
2. Disconnect wires at gas valve and slide burner  
drawer out.  
Establish a regular inspection schedule, the frequency  
depending on the local water condition and severity of  
service. Do not let the tubes clog up solidly. Clean out  
deposits over 1/16" in thickness.  
Gas Valve Removal  
1. Shut off gas supply to the pool heater. Remove  
gas piping to gas valve inlet.  
Although the illustration shows the mechanical clean-  
ing procedure of a small heater, it is typical of all sizes.  
The heater may be cleaned from the return header  
side as shown, without breaking pipe connections. It is  
preferable, however, to remove both headers for bet-  
ter visibility through the tubes and to be sure the  
ground up lime dust does not get into the system.  
2. Disconnect wires, pilot tubing and bleed line, if  
required.  
3. Turn vertical gas pipe from manifold slightly and  
unscrew gas valve.  
4. Reverse above procedure to re-install.  
Note that you do not remove the top pan or the heat  
exchanger, generally.  
After reaming, mount the wire brush in lieu of the  
auger and clean out the debris remaining in the tubes.  
Another method is to remove the heat exchanger,  
ream tubes and immerse heat exchanger in non-inhib-  
ited de-scale solvent.  
RAYPAKTUBECLEANINGKIT  
Extension Pieces (5)  
Auger with Carbide Tip  
Wire Brush  
Fig. 34: Tube Cleaning Kit  
Fig. 35: Tube Cleaning Procedure  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Main Burner and Orifice  
Removal  
Heat Exchanger Reassembly  
1. Heat exchanger header O-rings should be  
replaced with new ones.  
1. Remove screws and burner hold down bracket.  
NOTE: If the heat exchanger is sooted badly, the  
burner hold-down bracket and spacer can become  
distorted from direct flame impingement and this  
usually necessitates replacement of these parts.  
2. Install inlet-outlet and return water headers and  
install header retainer nuts and torque nuts even-  
ly.  
3. Install the four (4) corner clips between tube  
sheets and refractory. Replace "V" baffles.  
2. Lift burners from slotted spacer and slide from ori-  
fices. Clean with a wire brush.  
4. Install thermostat sensing bulbs in header wells  
and replace bulb retaining clips.  
3. Orifices usually do not need to be replaced. To  
clean, run either copper wire or wood through ori-  
fice. Do not enlarge hole. To remove orifice, use a  
socket wrench and remove the manifold. DO NOT  
overtighten when reinstalling.  
5. Install inlet and return pipes in water headers  
using pipe thread sealant.  
6. Install water pressure relief valve, flow switch, and  
low water cutoff devices if so equipped.  
Pilot Removal and Cleaning  
1. Disconnect pilot tubing at pilot and sensor/igniter  
wire. Remove screws holding pilot bracket to burn-  
er drawer.  
7. Open water supply and return shutoff valves. Fill  
heater and water piping system with water. Check  
heater and piping system for leaks at full line pres-  
sure. Run system circulating pump for a minimum  
of 1/2 hour with heater shutoff.  
2. Remove pilot and bracket, clean pilot of debris,  
small bugs, etc., with wire or small brush.  
8. Shut down entire system and vent all radiation  
units and high points in system piping. Check all  
strainers for debris.  
3. Replace pilot, pilot tubing, sensor ignition wires  
and check for leaks.  
9. Install flue collector, jacket top and inspection pan-  
els. Install top holding screws. Install draft diverter  
and vent piping if so equipped.  
Heat Exchanger Removal  
1. Shut water, gas and electricity off, close valves,  
relieve pressure and remove relief valve. Remove  
side inspection panels.  
10. If gas piping was disconnected, reconnect gas pip-  
ing system and check for leakage using a soap  
solution.  
2. Remove top holding screws.  
11. Double check electrical circuits, grounding con-  
nections and pump with wiring diagram supplied  
with heater.  
3. Remove draft diverter, lift and remove top and flue  
collector on stack type models. Remove inspec-  
tion panels.  
12. Check for correct water pressure and water level  
in the system. Make sure that system pump oper-  
ates immediately on the call for heat. The system  
is ready for operation.  
4. Loosen bolts and disconnect flange nuts on  
inlet/outlet header, loosen union(s) at gas pipe,  
and slide heater away from piping until studs clear  
the heater.  
5. Remove heat exchanger corner brackets.  
6. Remove combustion chamber clips at the four cor-  
ners of the heat exchanger.  
7. Lift heat exchanger straight up using caution not to  
damage refractory.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
canopy and flue collector off (on models 926-1826,  
remove the canopy hold-down brackets). Remove "V"  
baffles over tube(s) to be replaced. If no pipe unions  
have been provided, use the header as a union,  
remove the flange nuts off the inlet-outlet header,  
break gas connection and slide heater away from pip-  
ing, allowing room to work. Pull wedge clips out of  
control wells and remove sensing bulbs. Remove  
flange nuts from the return header and remove head-  
er. Lift heat exchanger straight up and out.  
Combustion Chamber Removal  
To remove the combustion chamber you must first  
have removed the heat exchanger. Unbolt metal com-  
bustion chamber retainer from top and remove  
combustion chamber panels individually.  
Heat exchanger header o-rings must be replaced with  
new ones. The tube may be cut out with a hack-saw or  
hammer and chisel adjacent to both tube sheets, leav-  
ing stubs in the tube sheets. Then proceed to collapse  
stubs in the tube sheets with a chisel or screwdriver.  
Use caution not to cut into the tube sheet.  
Replacement tubes will have the fins stripped off  
longer on one end. The long end is inserted into the  
opening of the tube sheet first; then the short end is fit-  
ted through the opposite tube sheet. If the tube ends  
become dented or bent, straighten at least four (4)  
inches back from the tube end by means of a tapered  
punch.  
Fig. 36: Refractory Panels—Top View  
Control Well Replacement  
Remove top, sensing bulb and clip. Collapse well tube  
at the open end and with a chisel, push through into  
the header, and remove the well through header.  
Insert a new well and roll into place. If a roller is not  
available, solder the well in place with silver solder.  
Insert tube roller into tube opening up to stop against  
tube, then push center rod in until roller is tight. Be  
careful to keep replacement tube squared up 1/8" out-  
side each tube sheet. A loose tube will sometimes pull  
toward the roller. Attach drill motor to tube roller, hold-  
ing it straight and level. Proceed to expand tube until  
the tool begins to grab. At this point, 1/2" to 1" should  
be exposed on the tool shank. Reverse drill motor or  
wrench out by hand. Care should be exercised to  
avoid applying excessive torque during rolling opera-  
tion and to avoid thinning out any part of the tube wall  
excessively over .015". Use same procedure at the  
opposite end of the tube.  
ImmersionWell  
Fig. 37: Immersion Well  
Apply line pressure test, and re-roll, if necessary,  
before replacing canopy.  
Tube Replacement Procedure  
Procedure For Cleaning Flue  
Gas Passageways  
On Raypak tube replacement may be affected without  
rolling, as a temporary means of repair, provided there  
are two or more tubes rolled into act as stays on left  
and right sides. The "O" rings should provide a seal up  
to 125 PSI working pressure. Use a 3/8" heavy duty  
reversible drill motor or larger, to power the tube roller.  
If a reversible drill is not available, after rolling the tube  
in, remove the drill motor and wrench out the roller. A  
tube roller is available from the factory.  
Soot can clog areas behind fins and cause eventual  
tube failure. Any sign of soot at base of burners or  
around outer jacket indicates a need for cleaning.  
1. Lift off draft hood and flue collector by removing  
bolts and screws.  
2. Remove "V" baffles from heat exchanger.  
3. Remove burner tray.  
Shut gas and power off to the unit, close the system off  
and drain the pool heater. Remove draft diverter.  
Remove the access panels and jacket top. Lift the  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4. Take garden hose and wash heat exchanger, mak-  
ing sure soot is removed from between fins. (Avoid  
excessive water against refractory).  
MAINTENANCE AND  
CARE  
5. Reassemble; when heater is fired, some steam will  
form from wet refractory. This is normal.  
To be followed one month after initial start-up and then  
quarterly.  
NOTE: In extreme cases it may be necessary to  
remove the heat exchanger completely for cleaning.  
The simplest method is steam cleaning at a local car  
wash. DO NOT WIRE BRUSH!  
1. Inspect top of heater and draft-hood for soot, and  
open fuel gas passageways.  
2. Clean main burners and pilot burner of dust and  
lint.  
CAUTION: Soot is combustible, so exercise  
extreme care.  
CAUTION: Soot may be combustible. Wet com-  
pletely when cleaning.  
Unitherm Governor  
Replacement  
3. Inspect and operate all controls and gas valve.  
4. Make visual check of burner and pilot flame.  
Flame pattern on main burner and pilot is indicat-  
ed on page 26. Yellow flame means restriction of  
air openings. Lifting or blowing flame indicates  
high gas pressure. Low flame means low gas  
pressure.  
1. Shut off water, gas and electricity, close valves,  
relieve pressure.  
2. Drain heat exchanger.  
3. Remove Unitherm Governor.  
5. Clean room air intake openings to ensure ade-  
quate flow of combustion and ventilation air.  
INLET/OUTLET HEADER  
6. Remove header opposite inlet pipes when clean-  
ing and inspect internal tubes for scale deposits. If  
scale does not form within first quarterly inspec-  
OUTLET  
INLET  
CAUTION: Combustion air must not be  
contaminated by corrosive chemical fumes which  
can damage the heater and void the warranty.  
GASKET  
tion, then inspect annually thereafter.  
UNITHERM GOVERNOR  
WITH POWER ELEMENT  
7. Keep heater air clear and free from combustible  
materials and other flammable and corrosive  
vapors and liquids.  
Fig. 38: Unitherm Governor—Models 926–1223  
8. Keep moving parts lubricated.  
To test operation of Unitherm Governor, place in hot  
water (110°F or higher) and watch for movement  
against spring. If no movement, replace.  
9. Manual operation of pressure/temperature relief  
valve at least once a year.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Winterizing Your Heater  
When heaters installed outdoors in freezing climate  
areas are to be shut down for the winter, please  
observe the following step-by-step procedure:  
1. Remove the drain plug or open the drain cock  
located on the inlet-outlet header. On larger  
heaters with external Unitherm Governor(s) and  
piping, locate plug at low point of Governor piping,  
or break connections and rotate inlet fittings 180  
degrees to face downward. Turn off manual main  
gas and main gas shut off.  
2. Disconnect compression fittings on both ends of  
the 1/8" copper tube and allow the tube to drain.  
Remove the "heat exchanger inspection panels"  
on the right side of the heater to gain access to the  
fitting on the return header. Remove return head-  
er.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
TROUBLESHOOTING  
IMPORTANT NOTICE  
These instructions are primarily intended for the use of qualified personnel specifically trained and experienced  
in the installation of this type of heating equipment and related system components. Installation and service  
personnel may be required by some states to be licensed. Persons not qualified shall not attempt to install this  
equipment nor attempt repairs according to these instructions.  
MECHANICAL (FOR QUALIFIED SERVICE PERSONNEL ONLY)  
PROBLEM  
CAUSE  
SOLUTION  
Harmonics, or whining noise  
U.G. Inoperative……………………  
Check movement by putting in hot  
water (110°F or higher). If no move-  
ment, replace.  
Locate the restriction and remove.  
Flush system and clean.  
Remove debris or blow out gas line.  
Scale forming in heat exchanger -  
clean heat exchanger and check  
pool pH and total alkalinity.  
*Debris or restriction in system……  
*Debris in gas line…………………..  
Lowflow……………………………...  
Heatergoingonandoff  
continously  
Dirty filter……………………………  
Lowwaterlevelinpool..……………  
External bypass setting out of  
adjustment…………………………..  
*Pressure switch out of  
Backwash filter.  
Raise water level.  
Adjust bypass  
adjustment…………………………..  
Adjust pressure switch  
Liming or scale forming on  
heatexchanger  
Poolwater…………………………....  
Highflowrates…………………….....  
U.G.Inoperative……………………..  
Recommended pH should be be-  
tween7.3and7.8totalalkalinity100-  
150PPMmaximum. Hardness-150-  
400 PPM maximum. (see page 2)  
Sooting  
Reduce by adding manual bypass  
valve and adjust by putting ther-  
mometer in header (1/4" NPT) drain  
opening. Set bypass so thermome-  
ter reads between 105° and 110°F.  
Check movement by putting in hot  
water (110°F or higher). If no move-  
ment, replace.  
*Airstarvation………………………..  
*Improperventing…………………....  
Refer to installation instructions.  
Follow recommended installation  
instructions.  
*Insects or debris clogging  
burnerintakeports…………………..  
Clean burners  
Pilot outage  
Lowgaspressure…………………....  
Restrictedpilot……………………....  
Weakpilotgenerator………………..  
Adjust gas pressure.  
Clean pilot.  
Replace pilot.  
Yellow lazy flame  
Lowgaspressure…………………....  
*Insects or debris clogging  
burnerintakeports…………………..  
Adjust gas pressure.  
Clean burners.  
*Usually occurs on initial start-up  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*Broken refractory caused by  
shippingdamageorimproper  
combustion…………………………..  
Excessive sooting of heat  
Outer jacket very hot  
(paint blistered)  
Replace refractory panels.  
exchanger…………………………...  
Determine cause of sooting &  
correct.  
Calculatetemperaturein°F/hr……... Heat rise (°F/hr.) = Htr.output  
Pool gallonage x 8.33  
Takes long time to heat pool  
or spa  
or refer to heater sizing chart.  
This does not take into account heat  
loss due to weather.  
Filternotrunninglongenough……....  
Reset time clock.  
Dirtyfilter…………………………….. Cleanfilter.  
Gas line or meter under-  
sized……….................................. Refer to installation instructions.  
Liming  
Bypassingtoomuchwater……….... Inspect bypass for movement, if no  
movement, replace.  
U/Gnotfunctioning……………….....  
Overacid…………………………......  
Overacid……………………………...  
Replace if no movement when  
heated.  
Replace well and maintain water  
chemistry properly.  
Replace heat exchanger and main-  
tain chemistry properly.  
Leaking at well.  
Leaking at heat exchanger.  
Gasket brittle and leaking-  
(overheated).  
Heaterrunningafterpump  
shutsoff……………………………...  
Refractorydamage………………….  
Sootedheater………………………..  
See pressure switch adjustment.  
Replace refractory.  
Determine cause of sooting and cor-  
rect.  
*Usually occurs on initial start-up  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL (ELECTRONIC IGNITION IID) IID  
WARNING: HIGH VOLTAGE. For qualified  
technicians ONLY.  
Intermittent Pilot System  
TROUBLESHOOTING HONEYWELL S8600  
NOTE: Some heaters may be equipped with an  
ignition module that shuts off pilot gas if the pilot fails  
to light. To reset, interrupt power to the heater.  
START  
TURN GAS SUPPLY OFF.  
TURN THERMOSTAT  
(CONTROLLER) TO CALL  
FOR HEAT  
POWER TO MODULE  
(24 V NOMINAL)  
YES  
NOTE: Before troubleshooting, familiarize yourself with the start-up and checkout  
procedure.  
Check line voltage power, low voltage transformer, limit controller, thermostat  
(controller) and wiring.  
NO  
NO  
Pull ignition lead and check spark at module.  
SPARK ACROSS  
IGNITER/SENSOR GAP  
YES  
Spark Okay?  
YES  
• Check ignition cable, ground wiring, ceramic insulator and gap, and correct.  
• Check boot of the ignition cable for signs of melting or buckling. Take protective  
action to shield cable and boot from excessive temperatures.  
TURN GAS SUPPLY ON  
PILOT BURNER LIGHTS?  
YES  
• Check that all manual gas valves are open, supply tubing and pressures are  
good, and pilot burner orifice is not blocked.  
• Check electrical connections between module and pilot operator on gas control.  
• Check for 24 Vac across PV-MV/PV terminals on module. If voltage is okay,  
replace gas control; if not, replace module.  
NO  
NO  
NOTE: If S8600H goes into lockout, reset system by removing power for at least  
60 seconds. Lockout is used on Pro. models.  
• Check continuity of ignition cable and ground wire.  
• Clean flame rod.  
• Check electrical connections between flame rod and module.  
• Check for cracked ceramic flame rod insulator.  
• Check that pilot flame covers flame rod and is steady and blue.  
• Adjust pilot flame.  
SPARK STOPS WHEN  
PILOT IS LIT?  
YES  
• If problem persists, replace module.  
• Check for 24 Vac across MV-MV/PV terminals. If no voltage, replace module.  
• Check electrical connections between module and gas control. If okay, replace  
gas valve or gas control operator, i.e. pilot gas valve, flow switch etc.  
NO  
NO  
MAIN BURNER LIGHTS?  
YES  
NOTE: IF S8600H goes into lockout, reset system.  
• Check continuity of ignition cable and ground wire.  
SYSTEM RUNS UNTIL  
CALL FOR HEAT ENDS?  
YES  
NOTE: If ground is poor or erratic, shutdowns may occur occasionally even though  
operation is normal at the time of checkout.  
• Check that pilot flame covers flame rod and is steady and blue.  
• If checks are okay, replace module.  
CALL FOR HEAT ENDS  
SYSTEM SHUTS OFF?  
YES  
• Check for proper thermostat (controller) operation.  
• Remove MV lead at module; if valve closes, recheck temperature controller and  
wiring; if not, replace gas valve.  
NO  
TROUBLESHOOTING  
ENDS  
Repeat procedure until trouble free operation is obtained.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RAYTHERM COMMERCIAL SWIMMING POOL HEATERS  
LIMITED WARRANTY  
RAYTHERM TYPE P  
SIZES 0926-4001  
SCOPE:  
Raypak, Inc. ("Raypak") warrants to the original owner that all parts of this boiler which are actually manufactured by Raypak will  
be free from failure under normal use and service for the specified warranty periods and subject to the conditions set forth in this  
Warranty. Labor charges and other costs for parts removal or reinstallation, shipping and transportation are not covered by this Warranty  
but are the owner's responsibility.  
HEAT EXCHANGER WARRANTY:  
Five (5) years from date of boiler installation. Includes only cupro nickel heat exchanger with bronze waterways.  
ANY OTHER PART MANUFACTURED OR FURNISHED BY RAYPAK:  
One (1) Year warranty from date of boiler installation, or eighteen (18) months from date of factory shipment based on Raypak's  
records, whichever comes first.  
SATISFACTORY PROOF OF INSTALLATION DATE, SUCH AS INSTALLER INVOICE, IS REQUIRED. THIS WARRANTY WILL BE  
VOID IF THE BOILER RATING PLATE IS ALTERED OR REMOVED.  
ADDITIONAL WARRANTY EXCLUSIONS:  
This warranty does not cover failures or malfunctions resulting from:  
1. Failure to properly install, operate or maintain the boiler in accordance with our printed instructions provided;  
2. Abuse, alteration, accident, fire, flood and the like;  
3. Sediment or lime buildup, freezing, or other conditions causing inadequate water circulation;  
4. High velocity flow exceeding boiler design rates;  
5. Failure of connected systems devices, such as pump or controller;  
6. Use of non-factory authorized accessories or other components in conjunction with the boiler system;  
7. Chemical contamination of combustion air or use of chemical additives to water.  
8. Misuse or neglect, including but not limited to freeze ups, and operating the heater with cabinet door off, having flow  
restrictions or obstructions between the heater outlet and pool/spa or not maintaining proper thermal balance. pH level must be  
between 7.3 and 7.8 and total alkalinity between 100 and 150 PPM. Total Dissolved Solids (TDS) must be no greater and 3000  
PPM, depending on pool/spa construction. (See page 2 of the I&O Manual for water chemistry information.)  
PARTS REPLACEMENT:  
Under this Warranty, Raypak will furnish a replacement for any failed part. The failed part must first be returned to Raypak if request-  
ed, with transportation charges prepaid, and all applicable warranty conditions found satisfied. The replacement part will be warranted  
for only the unexpired portion of the original warranty. Raypak makes no warranty whatsoever on parts not manufactured by it, but  
Raypak will apply any such warranty as may be provided to it by the parts manufacturer.  
TO MAKE WARRANTY CLAIM:  
Promptly notify the original installer, supplying the model and serial numbers of the unit, date of installation and description of the  
problem. The installer must then notify his Raypak distributor for instructions regarding the claim. If either is not available, contact Service  
Manager, Raypak, Inc., 2151 Eastman Ave, Oxnard, CA 93030 or call (805) 278-5300. In all cases proper authorization must first be  
received from Raypak before replacement of any part.  
EXCLUSIVE WARRANTY - LIMITATION OF LIABILITY:  
This is the only warranty given by Raypak. No one is authorized to make any other warranties on Raypak's behalf. THIS WARRAN-  
TY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF  
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. RAYPAK'S SOLE LIABILITY AND THE SOLE REMEDY  
AGAINST RAYPAK WITH RESPEC TO DEFECTIVE PARTS SHALL BE AS PROVIDED IN THIS WARRANTY. IT IS AGREED THAT  
RAYPAK SHALL HAVE NO LIABILITY, WHETHER UNDER THIS WARRANTY, OR IN CONTRACT, TORT, NEGLIGENCE OR OTHER-  
WISE, FOR ANY SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGE, INCLUDING DAMAGE FROM WATER LEAKAGE. Some  
states do not allow limitations on how long an implied warranty lasts, or for the exclusion of incidental or consequential damages. So the  
above limitation or exclusion may not apply to you.  
This Limited Warranty gives you specific legal rights. You may also have other rights which may vary from state to state. We sug-  
gest that you complete the information below and retain this certificate in the event warranty service is needed. Reasonable proof of the  
effective date of the warranty (date of installation) must be presented, otherwise, the effective date will be based on the rate of manu-  
facture plus thirty (30) days.  
Effective: 04-15-2007  
Replaces: 07-01-92  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 Fax (805) 278-5468  
Litho in U.S.A.  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Q See Security Camera qr404 411 User Guide
Radio Shack Clock Radio 12 220 User Guide
RBH Sound Speaker HS 615 User Guide
Ricoh All in One Printer 8035 User Guide
Ricoh Copier MP 1900 User Guide
RIDGID Drill SP6490 User Guide
Roberts Radio Clock Radio CR960 User Guide
Samsung Computer Monitor 2023 NW User Guide
Samsung Flat Panel Television 470 User Guide
Samsung Printer SRP270AP User Guide