Raypak Swimming Pool Heater 1802B 2342B User Guide

Hi Delta® - Type P  
Job:  
Engineer:  
Contractor:  
Prepared By:  
Model:  
Commercial Pool Heaters  
Models 1802B-2342B  
Date:  
Indoor/Outdoor:  
MBTUH Input:  
Sealed Combustion Chamber  
100% Factory Fire Tested  
Efficiency: 85%  
Minimum Non-condensing Inlet Temperature: 105°F  
Thermal Shock Proof Heat Exchanger  
Limited Twenty-year Thermal Shock Warranty  
Limited Five-year Heat Exchanger Warranty  
Diagnostic Center with Fault History  
PolyTuf Powder Coated Cabinet  
No Combustible Floor Shield Required  
Fan-assisted  
Non-ferrous Bypass  
Patented Burner Security Blanket  
Heat Exchanger  
Gas Train  
Options  
Bronze Headers  
Gas Pressure Regulators  
C-6 Ignition Module, Manual Reset  
D-21 TruSeal™ Direct Vent  
Right Side  
Left Side (Model 1802B  
Only)  
F-10 Low Water Cut-off, Remote  
Probe  
ASME Inspected and Stamped  
160 PSIG Working Pressure  
National Board Approved  
Cupro Nickel Finned Tubing  
ASME Steel Tube Sheet  
Silicone High Temp O-Rings  
125 PSIG ASME Pressure Relief Valve  
Temperature and Pressure Gauge  
Water Connections  
Left – Standard  
Right – Option A-6  
Bronze Pump, 120V, 60Hz  
Non-ferrous Pool Bypass  
Safety Shut-off Valves  
Firing Control Valves  
On/Off Firing  
Low Gas Pressure Switch, Manual  
Fuel  
Natural Gas  
Propane Gas  
Design Certified ANSI Z21.56/  
CSA 4.7  
S-2  
Dual High Gas Pressure  
Switches, Manual Reset  
SureRack Kit, Zone III and IV  
SureRack Add-on, Zone IV  
X-1  
X-2  
Burner  
Ultra-low NOx:  
Less than 30 PPM  
Y-241 Temperature Controller,  
1-4 Stages  
Regulatory Agency Requirements  
G-1 CSD-1  
Construction  
Controls  
Indoor/Outdoor Construction  
Enclosed Front Controls  
120V, 60Hz, 1Power Supply  
120/24V 60Hz Transformer  
100% Shut-off/Lockout  
Hot Surface Ignition Systems (2)  
Remote Flame Sensors (2)  
High Limit Control, Auto Reset  
On/Off Power Switch  
Manual Shut-off, Front-mounted  
Flow Switch  
Blocked Vent Pressure Switch  
Combustion Air Proving Switches  
Economaster Pump Time Delay  
Poolstat  
Venting  
Vent Location  
Top – Standard  
Rear – Option D-14  
Vent Termination Cap  
Outdoor – Option D-11  
Indoor, Horizontal –  
Option D-15  
Indoor, Vertical (by others)  
Combustion Air  
In-Line Filter Kit (TruSeal  
only) – Option D-17  
Air Intake Elbow –  
Option D-16  
L
W
Catalog No.: 6000.342B  
Effective: 8-15-08  
Replaces: 3-1-07  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Raymarine Microphone 86075 2 User Guide
RCA Satellite Radio DRD212NW User Guide
Roadmaster Car Speaker RS630 User Guide
Ryobi Grinder AG451 User Guide
Ryobi Outdoor Trimmer RY52001, RY52001A User Guide
Salton Kitchen Utensil RHFS1 User Guide
Samsung Cooktop SCD103 215 User Guide
Samsung Printer M202x User Guide
Schumacher Battery Charger SE 1072 User Guide
Sears Fitness Equipment 831287724 User Guide