Raypak Boiler Commercial Space Heating and Domestic Water User Guide |
TM
ADB Advanced Design Boiler
A NEW ERA IN BOILER DESIGN
Commercial Space Heating
and Domestic Water
Up to 97%
Thermal Efficiency
Multiple Venting
Options
Ultra low NOx
Reduced Vent
Sizes
Small Footprint
Aerodynamically
Stabilized Burner
Full Diagnostics
Download from Www.Somanuals.com. All Manuals Search And Download.
RELIABILITY
.
ADVANCED BURNER TECHNOLOGY
The heart of any boiler is the burner. It’s a critical
component that’s got to be designed right. That’s
why Raypak spent over four years perfecting the
ADB burner. The result is an industrial grade, fan-
assisted burner that provides superior perfor-
mance and is practically indestructible.
Standard high efficiency boilers use burners that
are either flimsy flame retention screens that burn
out, or radial perforated burners that eventually
clog and operate at reduced efficiencies. Unlike
these burner designs, the patented advanced
design burner will not clog or burn out. In fact,
Raypak is so confident, the new burner head is
backed with a TEN YEAR UNCONDITIONAL WARRANTY.
The ADB’s burner utilizes a solid metal bluff-body
burner head to generate a high-intensity aerody-
namically stabilized flame. The burner’s turbulent
mixing action reduces residence time and increas-
es flue gas recirculation. The result is clean, effi-
cient combustion with NOx emissions well within
the limits of the most restrictive air quality require-
ments.*
This is one tough burner and the warranty proves it.
* NOx emissions:
0-30 ppm depending on combustion air quality and
gas composition.
CENTRAL POINT WIRING AND DIAGNOSTICS
Raypak boilers have a well earned reputation for
being easy to service. The ADB is no exception. In
fact, the ADB sets a whole new standard for ser-
viceability – because it’s the first commercial boiler
to incorporate central point wiring (CPW).
ERROR
Unlike older control technologies, CPW individually
monitors each and every boiler control and safety
function. Using an intuitive LED display referred to
as the Operation Status Center, CPW gives split-
second feedback on boiler firing status. Should
service be required, the ADB will even indicate
which component requires attention by illuminat-
ing the appropriate fault LED located on the ADB’s
U-2 Diagnostics Panel.
HEAT
Download from Www.Somanuals.com. All Manuals Search And Download.
FLEXIBILITY
.
non-stainless internal fittings are either epoxy
coated or are chemically immune. The tube bundle
casing is fabricated from AL29-4C stainless steel,
and the outer jacket has an electrostatically applied
powder coat finish that is baked-on for superior
corrosion resistance and extra long life.
THE CONDENSING HEAT EXCHANGER (CHX)
The CHX is a scavenging heat exchanger that has
been specifically designed to capture the maximum
amount of energy from the ADB’s exhaust gases.
When used with a pre-heat tank and a storage tank,
the ADB/CHX system can squeeze out an amazing
97% of all heat of combustion energy contained in
the flue gases.
By segregating condensation from the primary
heat exchanger and the combustion chamber,
the CHX produces ultra-high efficiency without
sacrificing product life.
The CHX is built tough
enough to withstand the
demanding conditions
found in condensing
applications. All materials
used in the CHX are
VENTING OPTIONS
inherently corrosion
resistant and are treated
with advanced corrosion-
proof coatings for extra
protection. The headers
are bronze, the heat
CONVENTIONAL VENT
exchanger tubes are
made of cupro-nickel and
are coated with a
condensate impervious
epoxy enamel. All
THROUGH-WALL VENT
DIRECT VENT/SEALED
COMBUSTION
VERTICAL VENT/SEALED
COMBUSTION
OUTDOOR
Download from Www.Somanuals.com. All Manuals Search And Download.
THE ADVANCED DESIGN BOILER
OPERATION STATUS CENTER
Central point wiring, standard operating lights,
full-boiler diagnostics.
WEATHER PROOF JACKET
VENT PRESSURE SWITCHES
Enhance safety by verifying proper
burner operation.
The heavy gauge steel exterior jacket is protected with
a baked-on UV-resistant Polytuf powder coat finish.
COMBUSTION AIR FAN
With easy-to-adjust combustion
air shutter.
UP-FRONT CONTROLS
Easy access to all controls and
gas train components.
ADVANCED BLUFF BODY
CORROSION RESISTANT
BURNER
Industrial-tough, solid metal burner
head won’t clog or burn out –
and it’s backed with a
STEEL
All metal fittings are galvanized
against rust.
TEN YEAR UNCONDITIONAL WARRANTY.
SPARK TO PILOT
RUGGED ALL BRONZE
IGNITION
HEADERS
The most dependable ignition
method available.
Are naturally corrosion resistant.
MINIMUM CLEARANCE
REQUIREMENTS
Only one inch of clearance
is required from combustible
surfaces.
VENT OUTLET FLEXIBILITY
The flue gas outlet can be
repositioned in the field to vent from
either the back or right side of the unit.
PRIMARY HEAT
EXCHANGER
Vertical, cylindrical, multi-pass
heat exchanger captures all
radiant energy, eliminating
the need for heavy refractory.
TUBE SHEET CONSTRUCTION
Eliminates the repair and
maintenance problems associated
with rolling tubes directly into
a casting.
CUPRO-NICKEL FINNED TUBES
Provide fast, efficient heat transfer with extended
tube life. Will not corrode or erode and can handle
aggressive and hard water with ease.
VIEWING PORT
Allows easy fine-tuning of the power burner.
SMALL FOOTPRINT
The ADB occupies less than 51/2 sq. ft. of floor space.
Download from Www.Somanuals.com. All Manuals Search And Download.
FEATURES
Advanced Fan-Assisted Burner with Aerodynamically Stabilized Flame
Design Certified ANSI Z21.13 and Z21.10.3
Ultra-Low NOx: Less than 30ppm
Reduced Footprint
Indoor/Outdoor Construction
Thermal Shock Resistant
20 Year Limited Warranty
Natural Gas or Propane (except 1501)
•
•
•
•
•
•
•
•
STANDARD EQUIPMENT
HEAT EXCHANGER
Bronze Headers
Integral Finned Tube Heat Exchanger
Copper For Type H4
•
•
Cupro-Nickel For WH1
ASME Inspected and Stamped 150 PSIG
National Board Approved
Factory Installed ASME Relief Valve
Temperature and Pressure Gauge
•
•
•
•
GAS CONTROL TRAIN
Manual Main Gas Shut-Off Cock
Main Gas Pressure Regulator
Safety Shut-Off Valve, Redundant
Firing Mode: On/Off
Factory Fire Tested
CSD-1 Compliant Gas Train
•
•
•
•
•
•
CONTROLS
120V, 60Hz, 1ø Power Supply
120/24V Transformer
100% Pilot Safety
Electronic Intermittent Ignition (IID)
High Limit Safeties
Central Point Wiring
Full Boiler Diagnostics
Fan Proving Switch
•
•
•
•
•
•
•
•
Flow Switch
Blocked Flue Switch
•
•
CONSTRUCTION
Front Controls: Enclosed
Polytuf Powder Coat Finish
Durable Indoor/Outdoor Construction
Right Side or Rear Connections
•
•
•
•
SHIP FOOT
MODEL INPUT OUTPUT
B
D
E
F
G
H
NPT
2
2-1/2
2-1/2
K
FLUE
8
10
12
M
P
WGT PRINT AMPS
2
(MBTU)
750
999
(MBTU) HEIGHT
NPT
1-1/2
1-1/2
1-1/2
Lbs.
680
720
780
Ft.
H 751
H 1001
H 1501
630
840
64
72
82
38
46
56
44-1/2 29-3/4
52-1/2 37-3/4
62-1/2 47-3/4
17-3/4
21-1/2
20-1/4
41
49
59
5.4
5.4
5.4
8
10
12
1499
1260
Dimensions are in inches. Ratings shown for elevations up to 5000 feet. For installation at elevations over 5000 feet, please contact manufacturer.
See catalog 2000.27 for complete installation dimensions.
RAYPAK CORPORATE OFFICE AND
PRINCIPAL MANUFACTURING FACILITY
2151 Eastman Avenue
Oxnard, CA 93030
(805) 278-5300 FAX: (800) 872-9725
RAYPAK CANADA LIMITED
2805 Slough St., Mississauga
Ontario, Canada L4T 1G2
(905) 677-7999 FAX: (905) 677-8036
Raypak, Inc. reserves the right to make product changes
or improvements at any time without notice
Catalog No. 3400.10G Effective: 07-15-03 Replaces: 07-01-01 Litho in USA ©1998-2001 Raypak, Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
|