Raritan Computer Server DKX2 108 User Guide

Blade Server Configuration Guide  
Dominion KX II Blade Server Configuration Guide – Release 2.1.10, v1.0  
Version: Dominion KX Release 2.1.10  
Date:  
July 9, 2009  
Applicable Dominion KX II models:  
DKX2-108, DKX2-116, DKX2-132  
DKX2-216, DKX2-232  
DKX2-416, DKX2-432, DKX2-464  
DKX2-832, DKX2-864  
Overview:  
This guide contains instructions on the configuration of IBM and Dell blade server  
chassis KVM and management modules to enable integration with the Dominion KX II  
blade server feature introduced in Release 2.1. The guide provides supplemental  
information to the Dominion KX II Users Guide featuring screen shots and detailed  
instructions.  
Contents:  
The guide contains instructions and screenshots for configuration of the following blade  
server types:  
IBM BladeCenter E or H with Advanced Management Module)  
Dell 1855/1955 with Analog KVM Module  
Dell M1000e with iKVM Module  
Related Documents:  
Dominion KX II User Guide (Release 2.1.10)  
Dominion KX II CIM Guide (Release 2.1.10)  
Dominion KX II Release Notes (Release 2.1.10)  
Caution:  
This guide has been prepared based on specific versions of the IBM and Dell blade  
servers, which may differ from the version you may have. Consult the manufacturer  
documentation for your particular version for more information.  
Proprietary and Confidential  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Certain operations performed via the SSH connection require “Supervisor” (administrator level)  
privileges (e.g. setting idle timeout), so the account has to be created accordingly.  
Here are some typical errors if Supervisor level control is not provided:  
Communication  
Error  
Error communicating with 'IBM-H-CHASSIS' connected to port '12' failed to 'failed to set Media Tray', <-7014:User does not have the authority to issue this  
command.>.  
Communication  
Error  
Error communicating with 'IBM-H-CHASSIS' connected to port '12' failed to 'connect to target', <-7014:User does not have the authority to issue this  
command.>.  
For example, “new_user” has been assigned a “Supervisor” role.  
The login ID can be created by selecting a login id that is currently “not used”, and can  
subsequently be edited by selecting it.  
Proprietary and Confidential  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Proprietary and Confidential  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Under Network Protocols, ensure that SSH Server is Enabled. SSH will be used to access the  
command line interface to control blade chassis operations  
The Administrative Management Module firmware version can be verified by accessing Service  
Tools > AMM Service Data.  
Proprietary and Confidential  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dell 1855/1955 Analog KVM Module  
From the Standard KVM Port invoke the Main menu using the current hot-key sequence. This  
may be set up to use any or all of the following:  
Scroll Lock + Left Alt + Scroll Lock + Slot Number  
Scroll Lock + Shift + Scroll Lock + Slot Number  
PrintScr + Slot Number  
Ctrl + Ctrl + Slot Number  
Select the Setup button to see this screen:  
Proprietary and Confidential  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Select Menu and then Display/Sort Key by Slot.  
Set a Screen Delay Time - the time delay before the OSCAR menu is displayed after it is  
invoked. Recommend a value of 8 seconds.  
If the hot-key sequence can be sent and executed within this timeframe, the OSCAR menu won’t  
be seen when switching.  
From the Setup menu, click on Flag to configure the Flag’s behavior.  
The flag serves as a visual confirmation of the slot you have connected to. Recommend to select  
Displayed and Timed so the flag is shown when first connected. This disappears after the  
Screen Delay Time specified earlier.  
Proprietary and Confidential  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Return to the Setup menu, click on Scan to ensure that no slots are to be scanned.  
From the Main screen, select Commands and make sure Scan Enable is NOT enabled.  
Proprietary and Confidential  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Return to the Setup screen and select Security. The Enable Screen Saver must be disabled and  
no password provided.  
If you forget to disable the screensaver and password you’ll encounter the following:  
From the Setup screen, Names can be edited but these are not used with the KX II.  
Proprietary and Confidential  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dell M1000e with iKVM Module  
From the standard KVM Port, invoke the Main screen using the configured hot-key sequence.  
This may be set up to use : PrintScreen, Alt-Alt, Ctrl-Ctrl, and/or Shift-Shift.  
Select Setup to see the following screen:  
Select the Menu button.  
Proprietary and Confidential  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Select Display/Sort Key by Slot  
Designate 1 of 4 possible hot-key sequences to invoke OSCAR (the Port Configuration Page  
must match the hot-key selection made here).  
Set a Screen Delay Time - the time delay before the OSCAR menu is displayed after it is  
invoked. Recommend a value of 8 seconds.  
If the hot-key sequence can be sent and executed within this time, the OSCAR menu won’t be  
seen when switching.  
Return to the Setup screen and click Security. The Enable Screen Saver must be disabled and  
no password provided.  
Proprietary and Confidential  
Download from Www.Somanuals.com. All Manuals Search And Download.  
If you forget to disable the screensaver and password you’ll encounter the following:  
Return to the Setup screen and select Flag. The flag serves as a visual confirmation of the slot  
you have been connected to. Check Displayed and Timed so the flag is shown when first  
connected and disappears after the delay interval (the 8 seconds specified earlier).  
Return to the Setup screen and select Language, select English.  
Proprietary and Confidential  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Return to the Setup screen and select Broadcast, ensure no slots are designated for broadcast.  
Return to the Setup screen and select Scan, ensure that no slots are designated for scan.  
Proprietary and Confidential  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setup for iKVM Module from the Chassis management Controller’s (CMC) Administrative GUI,  
need to:  
Ensure that Front Panel USB Video is NOT enabled. The Front Panel has priority over  
the connections at the rear, so any connections at the front will prevent proper operation.  
Ensure that Allow access to CMC CLI from iKVM is NOT enabled  
If the Front Panel USB/Video is enabled, you’ll see a message indicating contention between  
the Front Panel and Rear Panel Access:  
Dominion KX II Blade Server Configuration Guide  
July 9, 2009  
This note is intended for Raritan customers only; its use, in whole or part, for any other purpose without the express  
written permission from Raritan Computer, Inc. is prohibited.  
Copyright ©2009 Raritan Computer, Inc. CommandCenter, Dominion, and the Raritan company logo are  
trademarks or registered trademarks of Raritan, Inc. All rights reserved. All other marks are the property of their  
respective owners.  
Proprietary and Confidential  
Download from Www.Somanuals.com. All Manuals Search And Download.  

RCA Car Video System 811 727191W030 User Guide
RCA Universal Remote ADR460 User Guide
RedMax Trimmer SGCZ2401S CA User Guide
Renesas Network Card 4513 User Guide
Rosewill Computer Hardware G03 ATI9000 User Guide
Safety 1st Bouncy Seat 25033 User Guide
Samsung Cell Phone GH68 04620A User Guide
Sanyo Flat Panel Television DP32642 User Guide
SATO Printer GT 410 User Guide
Seagate Network Hardware Medalist 17242 User Guide