RAD Data comm TV Converter Box AMC 101 User Guide

AMC-101  
Universal Media Converter and Repeater  
Installation and Operation Manual  
Notice  
This manual contains information that is proprietary to RAD Data Communications. No part of this  
publication may be reproduced in any form whatsoever without prior written approval by RAD Data  
Communications.  
No representation or warranties for fitness for any purpose other than what is specifically mentioned in  
this manual is made either by RAD Data Communications or its agents.  
For further information contact RAD Data Communications at the address below or contact your local  
distributor.  
RAD data communications  
Headquarters  
RAD data communications  
US East  
RAD data communications  
US West  
12 Hanechoshet Street  
Tel Aviv 69710 Israel  
Tel: 972-3-6458181  
Fax: 972-3-6498250  
900 Corporate Drive  
Mahwah, NJ 07430 USA  
Tel: (201) 529-1100  
Fax: (201) 529-5777  
3631 South Harbor Boulevard  
Suite 250  
Santa Ana, CA 92704  
Tel: (714) 850-0555  
Fax: (714) 850-1555  
© 2000 RAD Data Communications  
Publication No. 333-200-06/00  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warranty  
This RAD product is warranted against defects in material and workmanship for a period of one year  
from date of shipment. During the warranty period, RAD will, at its option, either repair or replace  
products which prove to be defective. For warranty service or repair, this product must be returned to  
a service facility designated by RAD. Buyer shall prepay shipping charges to RAD and RAD shall pay  
shipping charges to return the product to Buyer. However, Buyer shall pay all shipping charges, duties  
and taxes for products returned to RAD from another country.  
Lim itation of Warranty  
The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance  
by Buyer, Buyer-supplied firmware or interfacing, unauthorized modification or misuse, operation  
outside of the environmental specifications for the product, or improper site preparation or  
maintenance.  
Exclusive Rem edies  
The remedies provided herein are the Buyer’s sole and exclusive remedies. RAD shall not be liable for  
any direct, indirect special, incidental, or consequential damages, whether based on contract, tort, or  
any legal theory.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Warnings  
The exclamation point within a triangle is intended to warn the operator or service  
personnel of operation and maintenance factors relating to the product and its  
operating environment which could pose a safety hazard.  
Always observe standard safety precautions during installation, operation and maintenance of this  
product. Only qualified and authorized service personnel should carry out adjustment, maintenance or  
repairs to this instrument. No adjustment, maintenance or repairs should be performed by either the  
operator or the user.  
Telecom m unication Safety  
The safety status of each of the ports on the AMC-101 is declared according to EN 41003 and is  
detailed in the table below:  
Safety Status  
Ports  
SELV*  
V.11, V.24, V.35, V.36, X.21, X.50, LAN  
TNV**  
FXO, FXS, E&M  
TNV operating within the limits of SELV  
ISDN, E1, T1, sub E1, sub T1, various outputs to  
modem  
None  
None  
Limited current  
ELV***  
Excessive voltage  
None  
*
SELV = Safety Extra-Low Voltage  
**  
***  
TNV = Telecommunications Network Voltage  
ELV = Extra-Low Voltage  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Regulatory Inform ation  
FCC-15 User Inform ation  
This equipment has been tested and found to comply with the limits of the Class A digital device,  
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against  
harmful interference when the equipment is operated in a commercial environment. This equipment  
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance  
with the instruction manual, may cause harmful interference to the radio communications. Operation  
of this equipment in a residential area is likely to cause harmful interference in which case the user will  
be required to correct the interference at his own expense.  
Warning per EN 55022  
This is a Class A product. In a domestic environment, this product may cause radio interference, in  
which case the user may be required to take adequate measures.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Declaration of Conform ity  
Manufacturers Name:  
RAD Data Communications Ltd.  
Manufacturers Address:  
12 Hanechoshet St.  
Tel Aviv 69710  
Israel  
declares that the product:  
Product Name:  
AMC-101  
Conforms to the following standard(s) or other normative document(s):  
EMC:  
EN 55022 (1994)  
Limits and methods of measurement of radio disturbance  
characteristics of information technology equipment.  
EN 50082-1 (1992)  
Electromagnetic compatibility - Generic immunity standards  
for residential, commercial and light industry.  
Safety:  
EN 60950 (1992/93) Safety of information technology equipment, including  
electrical business equipment.  
Supplementary Information:  
The product herewith complies with the requirements of the EMC Directive 89/336/EEC and the Low  
Voltage Directive 73/23/EEC. The product was tested in a typical configuration.  
Tel Aviv, October 10th, 1996  
Haim Karshen  
VP Quality  
European Contact: RAD Data Communications GmbH, Lyoner Strasse 14, 60528 Frankfurt am Main, Germany  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
CHAPTER 1 – INTRODUCTION  
1.1 General .............................................................................................................................................1-1  
Retimed Modules .................................................................................................................................1-1  
Transparent Modules ............................................................................................................................1-1  
1.2 Features ............................................................................................................................................1-2  
1.3 General Applications.........................................................................................................................1-3  
1.4 Fast Ethernet Applications.................................................................................................................1-6  
1.5 Specifications..................................................................................................................................1-10  
Indicators ...........................................................................................................................................1-10  
Controls..............................................................................................................................................1-10  
Power.................................................................................................................................................1-10  
Physical..............................................................................................................................................1-10  
Environment.......................................................................................................................................1-10  
CHAPTER 2 – INSTALLATION & SETUP  
2.1 Unpacking.........................................................................................................................................2-1  
Before Unpacking.................................................................................................................................2-1  
Unpacking Procedure ...........................................................................................................................2-1  
2.2 Site Requirements.............................................................................................................................2-1  
Power...................................................................................................................................................2-1  
Front and Rear Panel Clearance ............................................................................................................2-1  
Ambient Requirements .........................................................................................................................2-1  
Installation of a Single Unit....................................................................................................................2-2  
Installation of Two Units .......................................................................................................................2-3  
2.3 Cable Connections............................................................................................................................2-4  
AC Power Connection ..........................................................................................................................2-4  
Grounding............................................................................................................................................2-4  
2.4 AMC-101 Modules............................................................................................................................2-5  
MM/SC/13/R Module............................................................................................................................2-5  
MM/SC/13/T Module............................................................................................................................2-6  
MM/ST/13/R Module ............................................................................................................................2-7  
MM/ST/13/T Module ............................................................................................................................2-8  
SM/ST/13/R Module..............................................................................................................................2-9  
SM/ST/13/T Module............................................................................................................................2-10  
SM/FC/13/T Module ...........................................................................................................................2-11  
SM/ST/13L/R Module..........................................................................................................................2-12  
SM/ST/13L/T Module..........................................................................................................................2-13  
SM/SC/13L/R Module .........................................................................................................................2-14  
AMC-101 Installation and Operation Manual  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
SM/ST/13LH/R Module.......................................................................................................................2-15  
SM/FC/13LH/R Module.......................................................................................................................2-16  
SM/ST/15L/R Module..........................................................................................................................2-17  
SM/ST/15LH/R Module.......................................................................................................................2-18  
SM/FC/15LH/R Module.......................................................................................................................2-19  
MM/ST/85/T Module ..........................................................................................................................2-20  
SF1/ST/R Module................................................................................................................................2-21  
SF2/ST/R Module................................................................................................................................2-22  
SF1/FC/R Module................................................................................................................................2-23  
SF2/FC/R Module................................................................................................................................2-24  
CX/BNC/155/R Module.......................................................................................................................2-25  
CX/DIN/155/R Module .......................................................................................................................2-26  
STP/155/R Module..............................................................................................................................2-27  
STP/155/T Module..............................................................................................................................2-28  
UTP/155/R Module.............................................................................................................................2-29  
UTP/155/T Module.............................................................................................................................2-30  
UTP/100/R Module.............................................................................................................................2-31  
UTP/100/T Module.............................................................................................................................2-32  
100BT/B Module ................................................................................................................................2-33  
100BT/R Module ................................................................................................................................2-34  
10BT/B Module ..................................................................................................................................2-35  
CHAPTER 3 – OPERATION  
3.1 Controls and Indicators ....................................................................................................................3-1  
3.2 Dry Contact Circuit and Connector for Alarms.................................................................................3-3  
3.3 Turning On AMC-101 .......................................................................................................................3-4  
3.4 Normal Operation ............................................................................................................................3-5  
3.5 Turning Off AMC-101.......................................................................................................................3-5  
3.6 Troubleshooting Procedures.............................................................................................................3-5  
The POWER LED does not light ............................................................................................................3-5  
Data transmission difficulties.................................................................................................................3-5  
ii  
AMC-101 Installation and Operation Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
List of Figures  
Figure 1-1 Dissimilar Device Connectivity ..................................................................................................1-3  
Figure 1-2 Dual Similar Device Connectivity...............................................................................................1-3  
Figure 1-3 WRAP: Dual Single Mode (SM) to Multimode (MM) Conversion ...............................................1-4  
Figure 1-4 Single Interface SM to MM (Wrap).............................................................................................1-4  
Figure 1-5 FDDI and Fast Ethernet Operations............................................................................................1-5  
Figure 1-6 Half Duplex Point-to-Point Connection......................................................................................1-6  
Figure 1-7 Extending Half Duplex Point-to-Point Connection......................................................................1-6  
Figure 1-8 Repeater Half Duplex Connection over UTP..............................................................................1-7  
Figure 1-9 Extending Repeater Half Duplex Connection .............................................................................1-7  
Figure 1-10 Point-to-Point Full Duplex Connection.....................................................................................1-8  
Figure 1-11 Extending Point-to-Point Full Duplex Connection.....................................................................1-8  
Figure 1-12 Full Duplex Connection over UTP...........................................................................................1-9  
Figure 1-13 Extending Full Duplex Connection...........................................................................................1-9  
Figure 2-1 AMC-101 Rear Panel AC Version...............................................................................................2-2  
Figure 2-2 AMC-101 Rear Panel DC Version ..............................................................................................2-2  
Figure 2-3 Installation of a Single Unit ........................................................................................................2-2  
Figure 2-4 Installation of Two Units (a) .......................................................................................................2-3  
Figure 2-5 Installation of Two Units (b) .......................................................................................................2-4  
Figure 2-6 MM/SC/13/R Module Front Panel ..............................................................................................2-5  
Figure 2-7 MM/SC/13/T Module Front Panel ..............................................................................................2-6  
Figure 2-8 MM/ST/13/R Module Front Panel...............................................................................................2-7  
Figure 2-9 MM/ST/13/T Module Front Panel...............................................................................................2-8  
Figure 2-10 SM/ST/13/R Module Front Panel..............................................................................................2-9  
Figure 2-11 SM/ST/13/T Module Front Panel ............................................................................................2-10  
Figure 2-12 SM/FC/13/T Module Front Panel............................................................................................2-11  
Figure 2-13 SM/ST/13L/R Module Front Panel ..........................................................................................2-12  
Figure 2-14 SM/ST/13L/T Module Front Panel ..........................................................................................2-13  
Figure 2-15 SM/SC/13L/R Module Front Panel..........................................................................................2-14  
Figure 2-16 SM/ST/13LH/R Module Front Panel .......................................................................................2-15  
Figure 2-17 SM/FC/13LH/R Module Front Panel.......................................................................................2-16  
Figure 2-18 SM/ST/15L/R Module Front Panel ..........................................................................................2-17  
Figure 2-19 SM/ST/15LH/R Module Front Panel .......................................................................................2-18  
Figure 2-20 SM/FC/15LH/R Module Front Panel.......................................................................................2-19  
Figure 2-21 MM/ST/85/T Module Front Panel...........................................................................................2-20  
Figure 2-22 SF1/ST/R Module Front Panel ................................................................................................2-21  
Figure 2-23 SF2/ST/R Module Front Panel ................................................................................................2-22  
Figure 2-24 SF1/FC/R Module Front Panel................................................................................................2-23  
Figure 2-25 SF2/FC/R Module Front Panel................................................................................................2-24  
Figure 2-26 CX/BNC/155/R Module Front Panel .......................................................................................2-25  
Figure 2-27 CX/DIN/155/R Module Front Panel........................................................................................2-26  
Figure 2-28 STP/155/R Module Front Panel..............................................................................................2-27  
Figure 2-29 STP/155/T Module Front Panel ..............................................................................................2-28  
Figure 2-30 UTP/155/R Module Front Panel.............................................................................................2-29  
Figure 2-31 UTP/155/T Module Front Panel .............................................................................................2-30  
Figure 2-32 UTP/100/R Module Front Panel.............................................................................................2-31  
Figure 2-33 UTP/100/T Module Front Panel .............................................................................................2-32  
Figure 2-34 100BT/B Module Front Panel.................................................................................................2-33  
Figure 2-35 100BT/R Module Front Panel.................................................................................................2-34  
AMC-101 Installation and Operation Manual  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
List of Tables  
Figure 2-36 10BT/B Module Front Panel...................................................................................................2-35  
Figure 3-1 AMC-101 Front Panel................................................................................................................3-1  
Figure 3-2 Jumper Locations and Functions ................................................................................................3-2  
Figure 3-3 Connector Pin Assignment..........................................................................................................3-3  
Figure 3-4 AMC-101 Block Diagram...........................................................................................................3-4  
List of Tables  
Table 1-1 Optical Module Characteristics ..................................................................................................1-11  
Table 1-2 Electrical Module Characteristics................................................................................................1-13  
Table 1-3 Bridging Modules ......................................................................................................................1-13  
Table 2-1 STP/155/R Pinout ......................................................................................................................2-27  
Table 2-2 STP/155/T Pinout ......................................................................................................................2-28  
Table 2-3 UTP/155/R Pinout .....................................................................................................................2-29  
Table 2-4 UTP/155/T Pinout .....................................................................................................................2-30  
Table 2-5 UTP/100/R Pinout .....................................................................................................................2-31  
Table 2-6 UTP/100/T Pinout .....................................................................................................................2-32  
Table 2-7 100BT/B Module Pinout............................................................................................................2-33  
Table 2-8 100BT/R Module Pinout............................................................................................................2-34  
Table 2-9 10BT/B Module Pinout..............................................................................................................2-35  
Table 3-1 AMC-101 Front Panel Indicators..................................................................................................3-1  
Table 3-2 AMC-101 Front Panel Controls....................................................................................................3-1  
Table 3-3 Functions and Settings.................................................................................................................3-2  
Table 3-4 Connector Pin Assignment...........................................................................................................3-3  
iv  
AMC-101 Installation and Operation Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1  
Introduction  
1.1 General  
The AMC-101, a Universal Converter and Repeater, provides retimed or  
transparent conversion of optical and electrical signals for ATM, FDDI, Fast  
Ethernet and other protocols at data rates up to 155 Mbps. The modularity  
of the AMC-101 interfaces enables field-changeable conversion between  
any two media.  
Transparent modules provide cost-effective media conversion without  
reclocking. Retimed modules provide media conversion with reclocking,  
which enables the AMC-101 to be used as a repeater. These modules can  
also be set for transparent operation.  
AMC-101 is supplied as a standalone unit. Special hardware for mounting  
either a single unit or two units side-by-side in a 19" rack can be ordered  
separately.  
The AMC-101 provides retimed media conversion for the following ATM  
interfaces:  
Retim ed Modules  
TAXI (100 Mbps)  
STM-1  
STS-3c  
STS-1 over optical and electrical interfaces.  
Retimed conversion is also available for FDDI and Fast Ethernet between  
single mode and multimode fiber, and for extending FDDI UTP  
connections over fiber. The retimed modules provide rate selection for 51,  
100 or 155 Mbps. When set to one of these rates, the retimed module  
regenerates and reclocks the incoming signal and acts as an ATM or FDDI  
repeater. When the switch is set to "OTHER", the modules regenerate the  
signal without reclocking as transparent modules do.  
Transparent  
Modules  
The AMC-101 provides transparent conversion for any two-level optical  
protocol. Transparent modules are recommended for short distances and  
for all fiber and copper applications at less than 100 Mbps.  
A special WRAP button activates loopbacks at the two interfaces. This can  
be used for test purposes or for special applications as explained later.  
General  
1-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1 - Introduction  
AMC-101 Installation & Operation Manual  
1.2 Features  
Modular Media Converter and Repeater, Media types supported:  
Single Mode Fiber  
Multimode Fiber  
STP  
UTP  
Coax  
Retimed media conversion for 51 Mbps, 100 Mbps and 155 Mbps.  
Transparent media conversion up to 155 Mbps.  
In retimed mode can be used as a Fiber Optic or copper repeater  
Protocols supported in retimed mode:  
51 Mbps OC-1  
100 Mbps TAXI  
155 Mbps OC-3  
155 Mbps STS-3c over UTP/STP  
155 Mbps STS-3c/STM-1 over Coax  
FDDI  
100BaseT (Fast Ethernet).  
Transparent mode supports any two-level optical protocol including:  
Ethernet  
Token Ring  
Protocols supported in retimed mode (fiber and copper) performed at  
less than 100 Mbps.  
Complies with ATM forum specifications.  
Multiple connector types are available for both electrical and optical  
interfaces.  
1-2  
Features  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC-101 Installation & Operation Manual  
Chapter 1 - Introduction  
1.3 General Applications  
A single AMC-101 is used to connect two devices operating with different  
fiber or electrical interfaces (see Figure 1-1).  
UTP Cat 5  
155 Mbps  
1300 nm  
Single Mode Fiber  
ATM Station  
AMC-101  
ATM Switch  
Figure 1-1 Dissimilar Device Connectivity  
A pair of AMC-101s connect two similar devices over different media types  
(see Figure 1-2).  
Coax  
Coax  
155 Mbps  
155 Mbps  
AMC-101  
AMC-101  
AMC-101  
AMC-101  
AMC-101  
AMC-101  
ATM Switch  
ATM Switch  
PTT Single Mode  
1300 nm  
MMF  
1300 nm  
MMF  
1300 nm  
FDDI  
FDDI  
MMF  
850 nm  
MMF  
850 nm  
Token Ring  
Token Ring  
Figure 1-2 Dual Similar Device Connectivity  
General Applications  
1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1 - Introduction  
AMC-101 Installation & Operation Manual  
A single AMC-101 in WRAP mode can be used for double conversion  
between single mode and multimode fiber for a dual attached FDDI station  
or concentrator (see Figure 1-3).  
Figure 1-3 WRAP: Dual Single Mode (SM) to Multimode (MM) Conversion  
A single AMC-101 equipped with a single interface in WRAP mode can be  
used for conversion between single mode and multimode fiber  
(see Figure 1-4).  
1300 nm Multimode  
1300 nm Single Mode  
ATM Switch  
ATM Switch  
AMC-101  
in WRAP Mode  
Figure 1-4 Single Interface SM to MM (Wrap)  
1-4  
General Applications  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC-101 Installation & Operation Manual  
Chapter 1 - Introduction  
The FDDI applies scrambling to data when operating over UTP, but not  
doing so when operating over fiber. Because of this, AMC-101 can only  
work in pairs for extending FDDI connections over fiber (see Figure 1-5).  
Fiber  
UTP Cat 5  
UTP Cat 5  
AMC-101  
AMC-101  
FDDI  
FDDI  
Figure 1-5 FDDI and Fast Ethernet Operations  
General Applications  
1-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1 - Introduction  
AMC-101 Installation & Operation Manual  
1.4 Fast Ethernet Applications  
Point to Point Link using a pair of Fiber Optic Cables running in HD  
(Half Duplex) 100-BaseFX:  
Problem :  
In a point to point application, in HD, the maximum range is limited  
to 412m.  
Fiber Optic Link  
Up to 412m  
Server  
Printer  
Fiber Optic Link  
Up to 412m  
Laptop  
PC  
Figure 1-6 Half Duplex Point-to-Point Connection  
Solution:  
Using two AMC-M/100BT/B modules can extend the range up to tens of  
kilometers.  
Fiber Optic Link  
UTP  
UTP  
Up to tens of kilometers  
Server  
Printer  
AMC-101  
AMC-101  
with AMC-M/100BT/B  
with AMC-M/100BT/B  
Fiber Optic Link  
Up to tens of kilometers  
UTP  
UTP  
PC  
AMC-101  
with AMC-M/100BT/B  
Laptop  
AMC-101  
with AMC-M/100BT/B  
Figure 1-7 Extending Half Duplex Point-to-Point Connection  
1-6  
Fast Ethernet Applications  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC-101 Installation & Operation Manual  
Chapter 1 - Introduction  
Repeater based LAN Link using standard UTP at HD (Half Duplex).  
Problem :  
Range is limited to 100m from the repeater.  
UTP  
Up to 100m  
Fast Ethernet Station  
(Laptop)  
Repeater  
UTP  
Up to 100m  
Fast Ethernet Station  
Figure 1-8 Repeater Half Duplex Connection over UTP  
Solution:  
Using two AMC-101s with AMC-M/100BT/B modules can extend the range  
up to tens of kilometers.  
UTP  
Up to 100m  
Fast Ethernet Station  
(Laptop)  
UTP < 80m  
Repeater  
Fiber Optic Link  
UTP < 80m  
Fast Ethernet Station  
Up to tens of kilometers  
AMC-101  
AMC-101  
with AMC-M/100BT/B Module with AMC-M/100BT/B Module  
Figure 1-9 Extending Repeater Half Duplex Connection  
Fast Ethernet Applications  
1-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1 - Introduction  
AMC-101 Installation & Operation Manual  
Extension of a point to point FD (Full Duplex) Fast Ethernet connection:  
Problem :  
The distance between two FD stations running on UTP needs to be  
extended.  
UTP  
Up to 100m  
FD Fast Ethernet Station  
FD Fast Ethernet Station  
Figure 1-10 Point-to-Point Full Duplex Connection  
Solution:  
Using two AMC-101s with AMC-M/100BT/R modules can extend the range  
up to tens of kilometers.  
FD Fiber Optic Link  
Up to tens of kms  
UTP  
UTP  
Up to 80m  
Up to 80m  
FD Fast Ethernet Station  
FD Fast Ethernet Station  
AMC-101 with  
AMC-M/100BT/R Module  
AMC-101 with  
AMC-M/100BT/R Module  
Figure 1-11 Extending Point-to-Point Full Duplex Connection  
1-8  
Fast Ethernet Applications  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC-101 Installation & Operation Manual  
Chapter 1 - Introduction  
Extension of a Switched Based Fast Ethernet LAN (FD - Full Duplex)  
Problem :  
The range of a FD Fast Ethernet LAN running on UTP has to be extended.  
UTP  
Up to 100m  
IBM Printer  
UTP  
Up to 100m  
Fast Ethernet Laptop Station  
FD Fast Ethernet Switch  
UTP  
Up to 100m  
Fast Ethernet Station  
Figure 1-12 Full Duplex Connection over UTP  
Solution:  
Using AMC-101s with AMC-M/100BT/R modules can extend the range up  
to tens of kilometers.  
Fiber Optic Link  
Up to tens of kilometers  
Printer with  
AMC-101  
with AMC-M/100BT/R Module  
Fiber Optic Transceiver  
Running FD Fast Ethernet  
UTP < 80m  
UTP < 80m  
UTP  
Up to 100m  
FD Fast Ethernet Station  
(Laptop)  
FD Fast  
Ethernet Switch  
Fiber Optic Link  
Up to tens of kilometers  
UTP < 80m  
AMC-101  
with AMC-M/100BT/R Module  
AMC-101  
FD Fast Ethernet Station  
with AMC-M/100BT/R Module  
Figure 1-13 Extending Full Duplex Connection  
Specifications  
1-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1 - Introduction  
AMC-101 Installation & Operation Manual  
1.5 Specifications  
Data Rate  
Up to 155 Mbps  
POWER (PWR)  
ON when unit is powered  
Indicators  
FAULT (FLT)  
WRAP  
BLINKS when card configuration is wrong  
ON when the two interfaces are wrapped  
SIG  
ON when received signal from Rx is valid  
BLINKS when the PLL is out of lock  
WRAP  
For double conversion or test purposes  
For data rate selection 51, 100, 155 Mbps  
For transparent mode  
Controls  
RATE  
OTHER  
AC source  
90-260 VAC, 16 ± 0.4 Watts,  
47-63 Hz  
Power  
DC source  
-48 VDC  
Height  
Width  
Depth  
Weight  
4.4 cm / 1.8 in (1U)  
Physical  
21.6 cm / 8.5 in  
24.2 cm / 9.5 in  
1.1 kg / 2.8 lb  
Temperature  
Humidity  
0o-50oC/32o-122oF  
Environm ent  
Up to 95%, non-condensing  
1-10  
Specifications  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC-101 Installation & Operation Manual  
Chapter 1 - Introduction  
Table 1-1 Optical Module Characteristics  
Module Nam e  
Protocols  
Fiber Type  
Connector Typical Dynam ic Optical Sensitivity  
Supported (Wavelength)  
Type  
Distance  
Range  
Power  
(Typical)  
MM/ST/85*  
Token Ring,  
Ethernet only (850 nm)  
62.5/125  
ST  
SC  
2 Km /  
18 dB  
-18 dBm -30 dBm  
-18 dBm -31 dBm  
1.2 mile  
2 Km /  
MM/SC/13**  
TAXI, FDDI,  
Fast Ethernet, (1300 nm)  
STS-1, STS-  
62.5/125  
17 dB  
17 dB  
28 dB  
1.2 mile  
3c/STM-1  
MM/ST/13**  
SF1/FC***  
TAXI, FDDI,  
62.5/125  
ST  
2 Km /  
-18 dBm -31 dBm  
-12 dBm -29 dBm  
Fast Ethernet (1300 nm)  
STS-3c/STM-1,  
STS-1  
1.2 mile  
TAXI, FDDI,  
Fast Ethernet,  
STS-3c/STM-1,  
STS-1  
9/125  
FC-PC  
40 Km /  
Transmit  
1300 nm  
(Single  
Strand)  
24.8 mile  
Receive  
1550 nm  
SF2/FC***  
SF1/ST***  
SF2/ST***  
SM/FC/13**  
TAXI, FDDI,  
Fast Ethernet,  
STS-3c/STM-1,  
STS-1  
9/125  
FC-PC  
40 Km /  
28 dB  
28 dB  
28 dB  
-12 dBm -29 dBm  
-12 dBm -29 dBm  
-12 dBm -29 dBm  
Transmit  
1550 nm  
(Single  
Strand)  
24.8 mile  
Receive  
1300 nm  
TAXI, FDDI,  
Fast Ethernet,  
STS-3c/STM-1,  
STS-1  
9/125  
ST  
40 Km /  
Transmit  
1300 nm  
(Single  
Strand)  
24.8 mile  
Receive  
1550 nm  
TAXI, FDDI,  
Fast Ethernet,  
STS-3c/STM-1,  
STS-1  
9/125  
ST  
40 Km /  
Transmit  
1550 nm  
(Single  
Strand)  
24.8 mile  
Receive  
1300 nm  
TAXI, FDDI,  
Fast Ethernet,  
STS-3c/STM-1/  
STS-1  
9/125  
FC-PC  
FC-P  
25 Km /  
30 dB  
30 dB  
-15 dBm -31 dBm  
-12 dBm -31 dBm  
1300 nm  
15.5 mile  
SM/FC/13L**  
(LASER)  
TAXI, FDDI,  
Fast Ethernet,  
STS-3c/STM-1/  
STS-1  
9/125  
40 Km /  
1300 nm  
24.8 mile  
Specifications  
1-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1 - Introduction  
AMC-101 Installation & Operation Manual  
Table 1-1 Optical Module Characteristics (Cont.)  
Module Nam e  
Protocols  
Fiber Type  
Connector Typical Dynam ic Optical Sensitivity  
Supported (Wavelength)  
Type  
Distance  
Range  
Power  
(Typical)  
SM/FC/13LH*** TAXI, FDDI,  
9/125  
FC-PC  
60 Km /  
33 dB  
-2 dBm  
-34 dBm  
-34 dBm  
(LASER)  
Fast Ethernet  
STS-3c/STM-1,  
STS-1  
(1300 nm)  
37.2 mile  
SM/FC/15LH*** TAXI, FDDI,  
9/125  
FC-PC  
SC  
110 Km / 33 dB  
68.2 mile  
-2 dBm  
(LASER)  
Fast Ethernet  
STS-3c/STM-1,  
STS-1  
(1550 nm)  
SM/SC/13L**  
(LASER)  
TAXI, FDDI,  
9/125  
40 Km /  
30 dB  
30 dB  
30 dB  
33 dB  
30 dB  
-12 dBm -31 dBm  
-15 dBm -31 dBm  
-12 dBm -31 dBm  
Fast Ethernet, (1300 nm)  
STS-3c/STM-1,  
STS-1  
24.8 mile  
SM/ST/13**  
TAXI, FDDI,  
9/125  
ST  
25 Km /  
Fast Ethernet, (1300 nm)  
STS-3c/STM-1,  
STS-1  
15.5 mile  
SM/ST/13L**  
(LASER)  
TAXI, FDDI,  
9/125  
ST  
40 Km /  
Fast Ethernet, (1300 nm)  
STS-3c/STM-1,  
STS-1  
24.8 mile  
SM/ST/13LH*** TAXI, FDDI,  
9/125  
ST  
60 Km /  
-2 dBm  
-34 dBm  
(LASER)  
Fast Ethernet, (1300 nm)  
STS-3c/STM-1,  
STS-1  
37.2 mile  
SM/ST/15L**  
(LASER)  
TAXI, FDDI,  
9/125  
ST  
50 Km /  
31 mile  
-12 dBm -31 dBm  
Fast Ethernet, (1500 nm)  
STS-3c/STM-1,  
STS-1  
SM/ST/15LH*** TAXI, FDDI,  
9/125  
ST  
110 Km / 33 dB  
68.2 mile  
-2 dBm  
-34 dBm  
(LASER)  
Fast Ethernet, (1550 nm)  
STS-3c/STM-1,  
STS-1  
* Data Rates are switch-selectable from the front panel  
** Transparent only  
*** Retimed only  
Typical distances based on attenuation of 0.4 dB/Km for 1300 nm modules  
and 0.25 dB/Km for 1550 nm modules  
Note  
1-12  
Specifications  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC-101 Installation & Operation Manual  
Chapter 1 - Introduction  
Table 1-2 Electrical Module Characteristics  
Module Nam e  
Protocols  
Supported  
Cable Type  
Connector  
Type  
Range Im pedance  
(Ohm s)  
UTP/155*  
STP/155*  
UTP/100*  
STS-3c  
UTP Cat 5  
STP Type 1  
UTP Cat 5  
Coax  
Shielded RJ-45  
100 m  
100  
150  
100  
75  
STS-3c  
FDDI,  
DB-9  
100 m  
Shielded RJ-45  
BNC  
100 m  
CX/BNC/155** STS-3c STM-1  
CX/DIN/155** STS-3c STM-1  
12.7 dB*  
Coax  
DIN 47295 1.6/5.6 Coaxial 12.7 dB*  
connector  
75  
* 50 m in transparent module  
** Retimed only, 135 m is attainable when using RG-59 B/U cable (At 78 MHz, according to square root of  
frequency law)  
Table 1-3 Bridging Modules  
Module Nam e  
Protocols  
Supported  
Cable Type  
Connector  
Type  
Range  
Im pedance  
(Ohm s)  
10BT/B*  
Ethernet  
UTP Cat 5  
Shielded RJ-45  
Shielded RJ-45  
100 m  
80 m  
100  
100  
100BT/B**  
Fast Ethernet  
Fast Ethernet  
UTP Cat 5  
UTP Cat 5  
100BT/R***  
Shielded RJ-45  
80 m  
100  
* Remote Ethernet bridge module  
** Remote Fast Ethernet bridge module  
*** Media Converter for Fast Ethernet (Tx to Fx)  
Specifications  
1-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1 - Introduction  
AMC-101 Installation & Operation Manual  
1-14  
Specifications  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2  
Installation & Setup  
2.1 Unpacking  
Inspect the equipment container before unpacking. Note and report  
evidence of damage immediately.  
Before Unpacking  
Unpacking  
Procedure  
Place the container on a clean flat surface. Cut all straps and open or  
remove top.  
Remove the unit carefully and place it securely on a clean surface.  
Remove all packing material.  
Inspect the unit for damage. Report any damage immediately.  
2.2 Site Requirem ents  
AMC-101 is powered by 100 to 240 VAC or -48 VDC.  
Power  
The unit should be installed within 1.5m (5 ft) of an easily accessible  
grounded AC outlet capable of supplying 230 V (115 V).  
Allow at least 90 cm (36 in) of clearance at the front of the unit for operator  
access. Allow at least 10 cm (4 in) clearance at the rear of the unit for power  
cord connection.  
Front and Rear  
Panel Clearance  
The ambient operating temperature of AMC-101 should be 0-40oC  
(32-122oF) at a relative humidity of up to 90%, non-condensing.  
Am bient  
Requirem ents  
Site Requirements  
2-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 - Installation & Setup  
AMC-101 Installation & Operation Manual  
Figure 2-1 AMC-101 Rear Panel AC Version  
Figure 2-2 AMC-101 Rear Panel DC Version  
Rack adapter components for installing a single unit include one short  
bracket and one long bracket. Each bracket is fastened to the side walls of  
the unit by two screws (with flat washers) which are inserted into the two  
front holes on the side wall (The unit is supplied with nuts already in place  
on the inner side wall). Note that the short bracket fastens to the left side of  
the unit, and the long bracket to the right side of the unit (see Figure 2-3).  
Installation of a  
Single Unit  
Once the brackets are fastened to the side walls, the unit is ready for  
installation in the 19" rack. Place the unit in the rack and fasten the brackets  
to the side rails of the rack by means of the two screws situated on each side  
(not included in the kit).  
Figure 2-3 Installation of a Single Unit  
2-2  
Site Requirements  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC-101 Installation & Operation Manual  
Chapter 2 - Installation & Setup  
Rack adapter components for installing two units include two long side rails  
(one for each unit) which slide one into the other fastening the two units  
together, and two short side brackets which hold the two units in the  
19'' rack (see Figure 2-4).  
Installation of  
Two Units  
Figure 2-4 Installation of Two Units (a)  
To install two units follow these instructions:  
1. Fasten one long side rail to each unit (right side to one unit, left side to  
the other unit) using the four screws and flat washers supplied. The side  
rails must be attached in opposing fashion, the narrow flange of the first  
rail opposite the wide flange of the second rail.  
2. Attach one short bracket opposite the side rail on each unit using the  
four screws and flat washers supplied.  
3. Slide the side rail of one unit into the side rail of the other unit, fastening  
the two units together (see Figure 2-5).  
4. Secure the supplied plastic caps to the ends of the rails, to prevent the  
units moving and to protect the rail ends.  
5. Place the assembled units in the rack and fasten the brackets to the side  
rails of the rack, by means of the four screws situated on each side  
(not included in the kit).  
Site Requirements  
2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 - Installation & Setup  
AMC-101 Installation & Operation Manual  
Figure 2-5 Installation of Two Units (b)  
2.3 Cable Connections  
AC power should be supplied to AMC-101 through a 1.5m (5 ft) standard  
power cord terminated by a grounded 3-wire plug.  
AC Power  
Connection  
When applying AC power, first connect the plug of the AC cable to the  
power connector on the rear panel of AMC-101 and then to the mains  
outlet.  
Warning  
Grounding  
Interrupting of the protective (grounding) conductor (inside or outside  
the instrument) or disconnecting the protective earth terminal can make  
this instrument dangerous. Intentional interruption of the grounding  
conductor is prohibited.  
Warning  
2-4  
AMC-101 Modules  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC-101 Installation & Operation Manual  
Chapter 2 - Installation & Setup  
2.4 AMC-101 Modules  
The upper part of the module front panel is AMC-R for a Retimed Timing  
mode; the lower part is AMC-T for a Transparent Timing mode. In both  
panels, the module name is labeled at panel’s bottom.  
MM/SC/13/R Module  
Figure 2-6 MM/SC/13/R Module Front Panel  
Wavelength:  
1300 nm  
SC  
Connector:  
Used with:  
Multimode fiber  
Protocols supported:  
STS-3c, STM-1, STS-1, FDDI, TAXI and  
Fast Ethernet  
Timing mode:  
Retimed  
Coding method:  
4B/5B, NRZ  
Optical output into 62.5/125 fiber: -18 dBm  
Receiver sensitivity:  
-31 dBm  
-14 dBm  
Maximum input power:  
AMC-101 Modules  
2-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 - Installation & Setup  
AMC-101 Installation & Operation Manual  
MM/SC/13/T Module  
Figure 2-7 MM/SC/13/T Module Front Panel  
Wavelength:  
1300 nm  
SC  
Connector:  
Used with:  
Multimode fiber  
Protocols supported:  
Any two level optical protocols up to  
155 Mbps  
Timing mode:  
Transparent  
4B/5B, NRZ  
Coding method:  
Optical output into 62.5/125 fiber: -18 dBm  
Receiver sensitivity:  
-31 dBm  
-14 dBm  
Maximum input power:  
2-6  
AMC-101 Modules  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC-101 Installation & Operation Manual  
Chapter 2 - Installation & Setup  
MM/ST/13/R Module  
Figure 2-8 MM/ST/13/R Module Front Panel  
Wavelength:  
Connector:  
1300 nm  
ST  
Used with:  
Multimode fiber  
Protocols supported:  
STS-3c, STM-1, STS-1, FDDI, TAXI and Fast  
Ethernet  
Timing mode:  
Retimed  
Coding method:  
4B/5B, NRZ  
Optical output into 62.5/125 fiber: -18 dBm  
Receiver sensitivity:  
-31 dBm  
-14 dBm  
Maximum input power:  
AMC-101 Modules  
2-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 - Installation & Setup  
AMC-101 Installation & Operation Manual  
MM/ST/13/T Module  
Figure 2-9 MM/ST/13/T Module Front Panel  
Wavelength:  
1300 nm  
ST  
Connector:  
Used with:  
Multimode fiber  
Protocols supported:  
Any two level optical protocols up to  
155 Mbps  
Timing mode:  
Transparent  
4B/5B, NRZ  
Coding method:  
Optical output into 62.5/125 fiber: -18 dBm  
Receiver sensitivity:  
-31 dBm  
-14 dBm  
Maximum input power:  
2-8  
AMC-101 Modules  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC-101 Installation & Operation Manual  
Chapter 2 - Installation & Setup  
SM/ST/13/R Module  
Figure 2-10 SM/ST/13/R Module Front Panel  
Wavelength:  
Connector:  
1300 nm  
ST  
Used with:  
Single mode fiber  
Protocols supported:  
STS-3c, STM-1, STS-1, FDDI, TAXI and Fast  
Ethernet  
Timing mode:  
Retimed  
4B/5B, NRZ  
-15 dBm  
-31 dBm  
-1 dBm  
Coding method:  
Optical output into 9/125 fiber:  
Receiver sensitivity:  
Maximum input power:  
AMC-101 Modules  
2-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 - Installation & Setup  
AMC-101 Installation & Operation Manual  
SM/ST/13/T Module  
Figure 2-11 SM/ST/13/T Module Front Panel  
Wavelength:  
1300 nm  
ST  
Connector:  
Used with:  
Single mode fiber  
Protocols supported:  
Any two level optical protocols up to  
155 Mbps  
Timing mode:  
Transparent  
4B/5B, NRZ  
-15 dBm  
Coding method:  
Optical output into 9/125 fiber:  
Receiver sensitivity:  
Maximum input power:  
-31 dBm  
-1 dBm  
2-10  
AMC-101 Modules  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC-101 Installation & Operation Manual  
Chapter 2 - Installation & Setup  
SM/FC/13/T Module  
Figure 2-12 SM/FC/13/T Module Front Panel  
Wavelength:  
1300 nm  
FC  
Connector:  
Used with:  
Single mode fiber  
Protocols supported:  
Any two level optical protocols up to  
155 Mbps  
Timing mode:  
Transparent  
4B/5B, NRZ  
-15 dBm  
Coding method:  
Optical output into 9/125 fiber:  
Receiver sensitivity:  
Maximum input power:  
-31 dBm  
-1 dBm  
AMC-101 Modules  
2-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 - Installation & Setup  
AMC-101 Installation & Operation Manual  
SM/ST/13L/R Module  
Figure 2-13 SM/ST/13L/R Module Front Panel  
Wavelength:  
1300 nm  
ST  
Connector:  
Used with:  
Single mode fiber  
Protocols supported:  
STS-3c, STM-1, STS-1, FDDI, TAXI and Fast  
Ethernet  
Timing mode:  
Retimed  
4B/5B, NRZ  
-12 dBm  
-31 dBm  
-1 dBm  
Coding method:  
Optical output into 9/125 fiber:  
Receiver sensitivity:  
Maximum input power:  
2-12  
AMC-101 Modules  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC-101 Installation & Operation Manual  
Chapter 2 - Installation & Setup  
SM/ST/13L/T Module  
Figure 2-14 SM/ST/13L/T Module Front Panel  
Wavelength:  
1300 nm  
ST  
Connector:  
Used with:  
Single mode fiber  
Protocols supported:  
Any two level optical protocols up to  
155 Mbps  
Timing mode:  
Transparent  
4B/5B, NRZ  
-12 dBm  
Coding method:  
Optical output into 9/125 fiber:  
Receiver sensitivity:  
Maximum input power:  
-31 dBm  
-1 dBm  
AMC-101 Modules  
2-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 - Installation & Setup  
AMC-101 Installation & Operation Manual  
SM/SC/13L/R Module  
Figure 2-15 SM/SC/13L/R Module Front Panel  
Wavelength:  
1300 nm  
SC  
Connector:  
Used with:  
Single mode fiber  
Protocols supported:  
STS-3c; STM-1, STS-1, FDDI, TAXI and Fast  
Ethernet  
Timing mode:  
Retimed  
4B/5B, NRZ  
-12 dBm  
-31 dBm  
-1 dBm  
Coding method:  
Optical output into 9/125 fiber:  
Receiver sensitivity:  
Maximum input power:  
2-14  
AMC-101 Modules  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC-101 Installation & Operation Manual  
Chapter 2 - Installation & Setup  
SM/ST/13LH/R Module  
Figure 2-16 SM/ST/13LH/R Module Front Panel  
Wavelength:  
Connector:  
1300 nm  
ST  
Used with:  
Single mode fiber  
Protocols supported:  
STS-3c; STM-1, STS-1, FDDI, TAXI and Fast  
Ethernet  
Timing mode:  
Retimed  
4B/5B, NRZ  
-2 dBm  
Coding method:  
Optical output into 9/125 fiber:  
Receiver sensitivity:  
Maximum input power:  
-34 dBm  
-1 dBm  
AMC-101 Modules  
2-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 - Installation & Setup  
AMC-101 Installation & Operation Manual  
SM/FC/13LH/R Module  
Figure 2-17 SM/FC/13LH/R Module Front Panel  
Wavelength:  
1300 nm  
FC  
Connector:  
Used with:  
Single mode fiber  
Protocols supported:  
STS-3c; STM-1, STS-1, FDDI, TAXI and Fast  
Ethernet  
Timing mode:  
Retimed  
4B/5B, NRZ  
-2 dBm  
Coding method:  
Optical output into 9/125 fiber:  
Receiver sensitivity:  
Maximum input power:  
-34 dBm  
-1 dBm  
2-16  
AMC-101 Modules  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC-101 Installation & Operation Manual  
Chapter 2 - Installation & Setup  
SM/ST/15L/R Module  
Figure 2-18 SM/ST/15L/R Module Front Panel  
Wavelength:  
Connector:  
1550 nm  
ST  
Used with:  
Single mode fiber  
Protocols supported:  
STS-3c, STM-1, STS-1, FDDI, TAXI and Fast  
Ethernet  
Timing mode:  
Retimed  
4B/5B, NRZ  
-12 dBm  
-31 dBm  
-1 dBm  
Coding method:  
Optical output into 9/125 fiber:  
Receiver sensitivity:  
Maximum input power:  
AMC-101 Modules  
2-17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 - Installation & Setup  
AMC-101 Installation & Operation Manual  
SM/ST/15LH/R Module  
Figure 2-19 SM/ST/15LH/R Module Front Panel  
Wavelength:  
1550 nm  
ST  
Connector:  
Used with:  
Single mode fiber  
Protocols supported:  
STS-3c; STM-1, STS-1, FDDI, TAXI and Fast  
Ethernet  
Timing mode:  
Retimed  
4B/5B, NRZ  
-2 dBm  
Coding method:  
Optical output into 9/125 fiber:  
Receiver sensitivity:  
Maximum input power:  
-34 dBm  
-1 dBm  
2-18  
AMC-101 Modules  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC-101 Installation & Operation Manual  
Chapter 2 - Installation & Setup  
SM/FC/15LH/R Module  
Figure 2-20 SM/FC/15LH/R Module Front Panel  
Wavelength:  
Connector:  
1550 nm  
FC  
Used with:  
Single mode fiber  
Protocols supported:  
STS-3c, STM-1, STS-1, FDDI, TAXI  
and Fast Ethernet  
Timing mode:  
Retimed  
4B/5B, NRZ  
-2 dBm  
Coding method:  
Optical output into 9/125 fiber:  
Receiver sensitivity:  
Maximum input power:  
-34 dBm  
-1 dBm  
AMC-101 Modules  
2-19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 - Installation & Setup  
AMC-101 Installation & Operation Manual  
MM/ST/85/T Module  
Figure 2-21 MM/ST/85/T Module Front Panel  
Wavelength:  
850 nm  
Connector:  
ST  
Used with:  
Multimode fiber  
Token Ring, Ethernet only  
Transparent  
4B/5B, NRZ, Manchester  
-18 dBm  
Protocols supported:  
Timing mode:  
Coding method:  
Optical output into 62.5/125 fiber:  
Receiver sensitivity:  
Maximum Input Power  
-30 dBm  
-12 dBm  
2-20  
AMC-101 Modules  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC-101 Installation & Operation Manual  
Chapter 2 - Installation & Setup  
SF1/ST/R Module  
Figure 2-22 SF1/ST/R Module Front Panel  
Wavelength:  
Connector:  
Transmit: 1300 nm; Receive: 1550 nm  
ST  
Used with:  
Single mode fiber  
Protocols supported:  
STS-3c, STM-1, STS-1, FDDI, TAXI  
and Fast Ethernet  
Timing mode:  
Retimed  
-12 dBm  
-29 dBm  
Optical output into 9/125 fiber:  
Receiver sensitivity:  
AMC-101 Modules  
2-21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 - Installation & Setup  
AMC-101 Installation & Operation Manual  
SF2/ST/R Module  
Figure 2-23 SF2/ST/R Module Front Panel  
Wavelength:  
Transmit: 1550 nm; Receice: 1300 nm  
Connector:  
ST  
Used with:  
Single mode fiber  
Protocols supported:  
STS-3c, STM-1, STS-1, FDDI, TAXI  
and Fast Ethernet  
Timing mode:  
Retimed  
-12 dBm  
-29 dBm  
Optical output into 9/125 fiber:  
Receiver sensitivity:  
2-22  
AMC-101 Modules  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC-101 Installation & Operation Manual  
Chapter 2 - Installation & Setup  
SF1/FC/R Module  
Figure 2-24 SF1/FC/R Module Front Panel  
Wavelength:  
Connector:  
Transmit: 1300 nm; Receive: 1550 nm  
FC  
Used with:  
Single mode fiber  
Protocols supported:  
STS-3c, STM-1, STS-1, FDDI, TAXI  
and Fast Ethernet  
Timing mode:  
Retimed  
-12 dBm  
-29 dBm  
Optical output into 9/125 fiber:  
Receiver sensitivity:  
AMC-101 Modules  
2-23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 - Installation & Setup  
AMC-101 Installation & Operation Manual  
SF2/FC/R Module  
Figure 2-25 SF2/FC/R Module Front Panel  
Wavelength:  
Transmit: 1550 nm; Receive: 1300 nm  
Connector:  
FC  
Used with:  
Single mode fiber  
Protocols supported:  
STS-3c, STM-1, STS-1, FDDI, TAXI  
and Fast Ethernet  
Timing mode:  
Retimed  
-12 dBm  
-29 dBm  
Optical output into 9/125 fiber:  
Receiver sensitivity:  
2-24  
AMC-101 Modules  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC-101 Installation & Operation Manual  
Chapter 2 - Installation & Setup  
CX/BNC/155/R Module  
Figure 2-26 CX/BNC/155/R Module Front Panel  
Connector:  
BNC  
Used with:  
Coax cable  
STS-3c, STM-1  
Retimed  
Protocols supported:  
Timing mode:  
Range calculation:  
12.7 dB at 78 MHz according to  
square root of frequency law  
Impedance:  
75 Ω  
AMC-101 Modules  
2-25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 - Installation & Setup  
AMC-101 Installation & Operation Manual  
CX/DIN/155/R Module  
Figure 2-27 CX/DIN/155/R Module Front Panel  
Connector:  
1.6/5.6 Coax  
Coax cable  
STS-3c, STM-1  
Retimed  
Used with:  
Protocols supported:  
Timing mode:  
Range calculation:  
12.7 dB at 78 MHz according to  
square root of frequency law;  
135 m is attainable when using  
RG-59 B/U cables  
(Cable length varies in accordance  
with cable type)  
Impedance:  
75 Ω  
2-26  
AMC-101 Modules  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC-101 Installation & Operation Manual  
Chapter 2 - Installation & Setup  
STP/155/R Module  
Figure 2-28 STP/155/R Module Front Panel  
Connector:  
DB-9  
Used with:  
STP type 1 cable  
STS-3c  
Protocols supported:  
Timing mode:  
Coding method:  
Range:  
Retimed  
NRZ  
100 m  
Impedance:  
150 Ω  
Table 2-1  
STP/155/R Pinout  
Pinout  
Pin 1  
Pin 2  
Pin 3  
Pin 4  
Pin 5  
Pin 6  
Pin 7  
Pin 8  
Pin 9  
Rx+  
Tx+  
Rx-  
Tx-  
AMC-101 Modules  
2-27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 - Installation & Setup  
AMC-101 Installation & Operation Manual  
STP/155/T Module  
Figure 2-29 STP/155/T Module Front Panel  
Connector:  
DB-9  
Used with:  
STP type 1 cable  
STS-3c  
Protocols supported:  
Timing mode:  
Coding method:  
Range:  
Transparent  
NRZ  
50 m  
Impedance:  
150 Ω  
Table 2-2  
STP/155/T Pinout  
Pinout  
Pin 1  
Pin 2  
Pin 3  
Pin 4  
Pin 5  
Pin 6  
Pin 7  
Pin 8  
Pin 9  
Rx+  
Tx+  
Rx-  
Tx-  
2-28  
AMC-101 Modules  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC-101 Installation & Operation Manual  
Chapter 2 - Installation & Setup  
UTP/155/R Module  
Figure 2-30 UTP/155/R Module Front Panel  
Connector:  
Shielded RJ-45  
UTP Cat 5  
STS-3c  
Used with:  
Protocols supported:  
Timing mode:  
Coding method:  
Range:  
Retimed  
NRZ  
100 m  
Impedance:  
100 Ω  
Table 2-3  
UTP/155/R Pinout  
Pinout  
Pin 1  
Pin 2  
Pin 3  
Pin 4  
Pin 5  
Pin 6  
Pin 7  
Pin 8  
Tx+  
Tx-  
Rx+  
Rx-  
AMC-101 Modules  
2-29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 - Installation & Setup  
AMC-101 Installation & Operation Manual  
UTP/155/T Module  
Figure 2-31 UTP/155/T Module Front Panel  
Connector:  
Shielded RJ-45  
UTP Cat 5  
STS-3c  
Used with:  
Protocols supported:  
Timing mode:  
Transparent  
NRZ  
Coding method:  
Range:  
50 m  
Impedance:  
100 Ω  
Table 2-4  
UTP/155/T Pinout  
Pinout  
Pin 1  
Pin 2  
Pin 3  
Pin 4  
Pin 5  
Pin 6  
Pin 7  
Pin 8  
Tx+  
Tx-  
Rx+  
Rx-  
2-30  
AMC-101 Modules  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC-101 Installation & Operation Manual  
Chapter 2 - Installation & Setup  
UTP/100/R Module  
Figure 2-32 UTP/100/R Module Front Panel  
Connector:  
Shielded RJ-45  
UTP Cat 5  
FDDI  
Used with:  
Protocols supported:  
Timing mode:  
Coding method:  
Retimed  
NRZ  
Range:  
100 m  
Impedance:  
100 Ω  
Table 2-5  
UTP/100/R Pinout  
Pinout  
Pin 1  
Pin 2  
Pin 3  
Pin 4  
Pin 5  
Pin 6  
Pin 7  
Pin 8  
Tx+  
Tx-  
Rx+  
Rx-  
AMC-101 Modules  
2-31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 - Installation & Setup  
AMC-101 Installation & Operation Manual  
UTP/100/T Module  
Figure 2-33 UTP/100/T Module Front Panel  
Connector:  
Shielded RJ-45  
UTP Cat 5  
FDDI  
Used with:  
Protocols supported:  
Timing mode:  
Coding method:  
Range:  
Transparent  
NRZ  
50 m  
Impedance:  
100 Ω  
Table 2-6  
UTP/100/T Pinout  
Pinout  
Pin 1  
Pin 2  
Pin 3  
Pin 4  
Pin 5  
Pin 6  
Pin 7  
Pin 8  
Tx+  
Tx-  
Rx+  
Rx-  
2-32  
AMC-101 Modules  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC-101 Installation & Operation Manual  
Chapter 2 - Installation & Setup  
100BT/B Module  
AMC-B  
TX LINK  
RX COLL  
100BTX  
Figure 2-34 100BT/B Module Front Panel  
Connector:  
Shielded RJ-45  
UTP Cat 5  
Used with:  
Protocols supported:  
Fast Ethernet (100 Base TX):  
Half Duplex on UTP side and Full Duplex  
on second module side  
Timing mode:  
Retimed & Bridged  
4B/5B, MLT-3  
Coding method:  
Range:  
80 m  
Impedance:  
Special Features  
100 Ω  
Bridging, Filtering,  
Half Duplex to Full Duplex conversion  
Table 2-7  
100BT/B Module Pinout  
Pinout  
Pin 1  
Pin 2  
Pin 3  
Pin 4  
Pin 5  
Pin 6  
Pin 7  
Pin 8  
Tx+  
Tx-  
Rx+  
Rx-  
AMC-101 Modules  
2-33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 - Installation & Setup  
AMC-101 Installation & Operation Manual  
100BT/R Module  
AMC-R  
TX LINK  
RX  
100BTX  
Figure 2-35 100BT/R Module Front Panel  
Connector:  
Used with:  
Shielded RJ-45  
UTP Cat 5  
Protocols supported:  
Fast Ethernet (100 Base TX):  
Half or Full Duplex (HDX to HDX or  
FDX to FDX)  
Timing mode:  
Retimed  
Coding method:  
4B/5B, MLT-3  
Range:  
80 m  
Impedance:  
100 Ω  
Table 2-8  
100BT/R Module Pinout  
Pinout  
Pin 1  
Pin 2  
Pin 3  
Pin 4  
Pin 5  
Pin 6  
Pin 7  
Pin 8  
Tx+  
Tx-  
Rx+  
Rx-  
2-34  
AMC-101 Modules  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC-101 Installation & Operation Manual  
Chapter 2 - Installation & Setup  
10BT/B Module  
AMC-B  
TX LINK  
COLL  
RX  
10BT  
Figure 2-36 10BT/B Module Front Panel  
Connector:  
Shielded RJ-45  
UTP Cat 5  
Used with:  
Protocols supported:  
Timing mode:  
Range:  
Ethernet (10Base-T): Half or Full Duplex  
Retimed  
100 m  
100 Ω  
Impedance:  
Table 2-9  
10BT/B Module Pinout  
Pinout  
Pin 1  
Pin 2  
Pin 3  
Pin 4  
Pin 5  
Pin 6  
Pin 7  
Pin 8  
Tx+  
Tx-  
Rx+  
Rx-  
10BT/B modules (Half Duplex or Full Duplex) operate with Transparent  
modules.  
Note  
AMC-101 Modules  
2-35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3  
Operation  
3.1 Controls and Indicators  
All controls and indicators are located on the front panel of AMC-101.  
AMC-R  
SIG  
AMC-R  
SIG  
OTHER  
155  
TX  
RX  
100  
51  
STP/155  
ST/SM  
1300  
PWR FLT  
WRAP  
2
A
B
C
1
Figure 3-1 AMC-101 Front Panel  
AMC-101 Front Panel Indicators  
Table 3-1  
Indicators  
POWER:  
FAULT:  
Description  
ON when unit is powered (GREEN)  
BLINKS when card configuration is wrong (RED)  
ON when the two interfaces are wrapped (GREEN)  
WRAP:  
Table 3-2  
AMC-101 Front Panel Controls  
Controls  
WRAP:  
RATE:  
Description  
Activates loopback at the two interfaces  
For data rate selection (51, 100, 155 Mbps)  
or transparent mode (other)  
Controls and Indicators  
3-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3 - Operation  
AMC-101 Installation & Operation Manual  
DB-9 Connector  
(ALARM)  
JP2  
AC  
AMC-RELAY  
(ALARM)  
Card  
Power Supply  
JP1  
GND  
JP2  
JP1  
JP4  
VCC  
JP6  
ERR-CFG  
JP7  
IDLE-EN  
AMC-101  
Module  
AMC-101  
Module  
LEDs Card  
Figure 3-2 Jumper Locations and Functions  
Table 3-3  
Functions and Settings  
Jum per ID  
Function  
ERR-CFG  
Conditional Setting  
JP2  
JP7  
Mounted (Factory Default)  
Idle-Enable  
If mounted, idle will be transmitted when no signal  
is received from the other side. Not mounted  
(Factory Default)  
3-2  
Controls and Indicators  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC-101 Installation & Operation Manual  
Chapter 3 - Operation  
3.2 Cable Connections  
DC adapter Connection.  
Grounding  
Note  
In order to protect the AMC-1 from electrostatic discharge (ESD), use a DC  
adapter where the (-) DC pole is connected to the protective earth.  
3.3 Dry Contact Circuit and Connector for Alarm s  
A dry circuit with a 9-pin D-type connector on the rear panel, has been  
added to the unit to signal minor and major alarms. The dry contact circuit  
is used to signal the following alarms:  
Alarm type  
Description  
RED ALARM  
Power Failure (DC voltage on board)  
Signal Detect Failure (to any of the unit modules)  
YELLOW ALARM  
CONFIG ALARM  
Improper Configuration (incompatible modules  
and/or data rates selected)  
Three pins are dedicated for each alarm: Common (COM), OK and FAIL.  
The COM pin is the input for each alarm. The user can drive the COM pin  
with any signal (0 to 5v). If the signal is received OK, the COM pin is  
connected to its corresponding OK pin; If there is a failure, the COM pin is  
connected to its corresponding FAIL pin. See Table 3-4 and Figure 3-3 for  
the connector pin assignments.  
Table 3-4 Connector Pin Assignment  
Alarm Type  
RED  
COM  
OK  
4
FAIL  
9
3
6
5
7
1
YELLOW  
CONFIG  
8
2
Figure 3-3 Connector Pin Assignment  
Dry Contact Circuit and Connector for Alarms  
3-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3 - Operation  
AMC-101 Installation & Operation Manual  
Exam ple:  
For the RED ALARM the common input (COM) pin is 9. If there is no power  
failure, it connects to pin 4 (OK). If there is a failure, pin 9 connects to pin 5  
(FAIL).  
3.4 Turning on the AMC-101  
Connect the AC cable of AMC-101 to the mains outlet. The POWER  
indicator on the front panel should light up.  
3-4  
Turning on the AMC-101  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AMC-101 Installation & Operation Manual  
Chapter 3 - Operation  
PWR LED  
Dry Contact  
Relay 1  
FLT LED  
WRAP LED  
Control  
Logic  
Relay 2  
WRAP Button  
Relay 3  
51  
100  
155  
RATE  
Switch  
Other  
Mux  
Control  
Mux  
Idle  
AMC-101 Module  
Fiber/Copper  
Transmitter  
Mux  
Control  
REF  
Fiber/Copper  
Receiver  
Retiming  
Status  
SIG LED  
Mux  
Idle  
Module Connector  
AMC-101 Module  
Fiber/Copper  
Transmitter  
REF  
Fiber/Copper  
Receiver  
Retiming  
Status  
SIG LED  
Frequency  
Sources  
Reference Frequency  
MUX  
Figure 3-4 AMC-101 Block Diagram  
Turning on the AMC-101  
3-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3 - Operation  
AMC-101 Installation & Operation Manual  
3.5 Norm al Operation  
Once powered on, the POWER indicator should light up and the FLT should  
be turned off. If the FLT indicator blinks, a configuration error exists: the  
combination of the card types and the selected data rate is illegal.  
Each AMC-101 module contains a SIG indicator. If the SIG indicator is  
turned off; no signal is received by the module. If the SIG is turned on; a  
signal is received by the module, and if the re-timing option is in use, the  
PLL is synchronized to the receive signal. If the SIG blinks, a signal is  
received by the module but the PLL is out of sync.  
A special circuitry can be configured to transmit idle signal in case of not  
receiving any signal from the other side. This option is enabled by the idle  
jumper (JP-6) and can be used for power measurements in case of absence  
of "real" data.  
The WRAP function can be locally activated at any time and causes the  
signal received by the module to be transmitted by the same module. If the  
module features retiming, the looped back signal is retimed and re-clocked.  
3.6 Turning off the AMC-101  
Disconnect the AMC-101 AC cable from the mains outlet.  
3.7 Troubleshooting Procedures  
Check the power cord connection on the back of the unit and at the mains  
outlet.  
The POWER LED  
does not light up  
Verify power availability at the mains outlet.  
Ensure that the plugged-in modules are compatible with the protocol used  
(media, data rate).  
Data transm ission  
difficulties  
Ensure that the FLT LED is off. (If the LED blinks, a configuration error exists:  
the combination of the module types and the selected data rate is illegal).  
Verify that the SIG LED is on and fixed. If the LED is off, no signal is being  
received by the module. If the LED is blinking, the module PLL is out of  
sync.  
Use the WRAP option to localize the problematic segment.  
3-6  
Troubleshooting Procedures  
Download from Www.Somanuals.com. All Manuals Search And Download.  

RCA Flat Panel Television 31Series User Guide
RF Link Technology Security Camera AWS 5832 VSR User Guide
RIDGID Saw BS14002 User Guide
Roland Stereo Amplifier CUBE 15x User Guide
Ryobi Saw TS1552DXL User Guide
Samsung Computer Drive 16MB User Guide
Sanyo Cordless Telephone CLT 2418 User Guide
SBC comm Conference Phone SBC 125 User Guide
Schumacher Battery Charger MCF 1 User Guide
Scotsman Ice Ice Maker FME1504 User Guide