Owner’s Manual
Installation and Operation
Model:
QVI-30FB
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
GUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
WARNING: IMPROPER INSTALLA-
TION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFOR-
MATION CONSULT A QUALIFIED IN-
STALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.
WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
ING PROPERTY DAMAGE, PER-
SONAL INJURY, OR DEATH.
1. This appliance may be installed in an af-
termarket, permanently located, manufac-
tured (mobile) home, where not prohibited
by local codes.
- Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
-
What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
2. This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed
plumber or gas fitter;
- Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
See Table of Contents for location of additional
Commonwealth of Massachusetts requirements.
Please contact your Quadra-Fire dealer with
any questions or concerns. For the location
of your nearest Quadra-Fire dealer, please
Printed in U.S.A. Copyright 2007
Quadra-Fire, a brand of Hearth & Home Technologies
1445 North Highway, Colville, WA 99114
This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471,
5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165,
6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426, 6774802,
6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250,
780403, 1418504 or other U.S. and foreign patents pending.
1
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF CONTENTS
Safety and Warning Information ................................................ 2
Service Parts Lists ..................................................................... 4
Î
Section 1: Approvals and Codes ............................................... 7
Appliance Certification................................................................... 7
Installation Codes.......................................................................... 7
HighAltitude Installations ............................................................... 7
Requirements for the Commonwealth of Massachusetts ............ 8
Section 2: Getting Started ......................................................... 9
Introducing the Quadra-Fire Gas Appliances ................................ 9
Pre-installation Preparation ........................................................... 9
Venting and Installation .................................................................. 9
Section 3: Installing the Insert ................................................ 12
Step 1 Installing the Vent System............................................ 12
Step 2 Positioning, Leveling, and Securing the Insert ............. 16
Step 3 The Gas Control Systems ........................................... 16
Step 4 The Gas Supply Line ................................................... 16
Step 5 Gas Pressure Requirements ...................................... 17
Step 6 Wiring the Appliance .................................................... 17
Step 7 Installing Logs and Ember Material .............................. 19
Shutter Settings ........................................................... 19
Positioning the Logs .................................................... 19
Placing the Ember Material.......................................... 19
Step 8 Installing Trim Surround ............................................... 19
Step 9 Before Lighting theAppliance ...................................... 20
Step 10 Lighting theAppliance .................................................. 21
After the Installation ..................................................................... 21
Section 4: Maintaining and Servicing Your Appliance ........ 22
Section 5: Troubleshooting .................................................... 23
Limited Lifetime Warranty ........................................................... 25
Î = Contains updated information.
3
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
Download from Www.Somanuals.com. All Manuals Search And Download.
Service Parts
QVI-30FB
Service Parts Diagram
8
20
9
10
19
12
11
18
13
17
14
15
Log Set Assembly
16
6
5
1
4
7
2
3
Part number list on following page.
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Î
Service Parts List
QVI-30FB
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your
dealers' VIP site. When ordering, supplyserial and model numbers to ensure correct service
parts.
AVAILABLE
TO SHIP IN
24 HOURS
ITEM
DESCRIPTION
SERIAL #
PART NUMBER
LOGS-QVI30FB
SRV2020-140
SRV2020-141
SRV2020-142
SRV340-704
SRV340-706
SRV340-705
SRV740-707
783-108A
Log Set Assembly
Y
1
2
3
4
5
6
7
8
Log 1
Log 2
Log 3
Log 4
Log 5
Log 6
Log 7
Slide Plate Assembly
2019-201
Slide Plate Handle
783-147A
Pre 002952745
Post 002952745
9
Baffle Assembly
2020-046
10
Burner NG, LP
2020-024
Y
434-0450
11
12
13
14
15
16
17
18
19
20
Andirion
2020-025
Grate Assembly
Glass Door Assembly
Rheostat Knob
Valve Cover Plate
Piezo Ignitor
GLA-FBINB
100-512
Y
Y
783-120
291-513
Y
Y
Y
100-510A
Rheostat Assembly
Junction Box
040-250A
GFK-160A
778-185
Blower Assembly
Cover Plate
107-531
Temp sensor
Y
Y
2020-059
Wiring Assembly
Vent Pipe Assembly
Glass Latch Assembly
Mineral Wool
768-380A
386-122A
Y
050-721
MYSTIC-EMBERS
Vermiculite Embers
Gasket Assembly
783-430A
Contains pilot Gasket, pilot bracket and air passage gaskets
Thermocouple
Thermopile
Pilot tube
446-511
Y
Y
Y
060-512
SRV485-301
SRV-PACK
NGK-QVI30FB
LPK-QVI30FB
446-505
Patch Kit
Conversion Kit NG
Y
Y
Y
Conversion Kit LP
Pilot Orifice NG
Pilot Orifice LP
Regulator NG
Regulator LP
446-517
Y
Y
Y
060-518
060-519
Additional service part numbers appear on following page.
5
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
Download from Www.Somanuals.com. All Manuals Search And Download.
Service Parts
QVI-30FB
Valve Assembly Parts Diagram
Standing Pilot ValveAssembly
6
7
1
8
2
9
3
4
5
10
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located
on your dealers' VIP site. When ordering, supply serial and model numbers to ensure
correct service parts.
AVAILABLE
TO SHIP IN
24 HOURS
ITEM
DESCRIPTION
Flex Ball Valve Assembly
SERIAL #
PART NUMBER
302-320A
060-522
1
Y
Y
Y
Valve NG
2
Valve LP
060-523
3
Pilot control Knob
Flame Control Knob
Valve Bracket
571-530
571-531
4
5
773-145
Pilot Assembly NG
Pilot Assembly LP
Orifice NG (#31A)
Orifice LP (#49A)
Bracket, Orifice
Bracket, Pilot
485-510A
485-511A
506-800
Y
Y
Y
Y
6
7
065-801
8
9
778-169
783-170
Flexible Gas Connector
477-301A
10
Y
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Approvals and
Codes
1
Appliance Certification
High Altitude Installations
U.L. Listed gas appliances are tested and approved with-
out requiring changes for elevations from 0 to 2,000 feet in
the U. S. A. and in Canada.
The Quadra-Fire appliance discussed in this Installers Guide
has been tested to certification standards and listed by the
applicable laboratories.
When installing this appliance at an elevation above 2,000
feet, it may be necessary to decrease the input rating by
changing the existing burner orifice to a smaller size. Input
rate should be reduced by 4% for each 1000 feet above a
2000 foot elevation in the U.S.A. or 10% for elevations
between 2000 and 4500 feet in Canada. If the heating value
of the gas has been reduced, these rules do not apply. To
identify the proper orifice size, check with the local gas
utility.
Certification
MODEL:
QVI-30FB
LABORATORY: Underwriters Laboratories
TYPE:
STANDARD:
Vented Gas Fireplace Heaters
ANSI Z21.88-2002•CSA2.33-2002•UL307B
Installation Codes
If installing this appliance at an elevation above 4,500 feet
(in Canada), check with local authorities.
The appliance installation must conform to local codes.
Before installing the appliance, consult the local building
code agency to ensure that you are in compliance with all
applicable codes, including permits and inspections.
In the absence of local codes, the fireplace installation must
conform to the National Fuel Gas CodeANSI Z223.1 (in the
United States) or the CAN/CGA-B149 Installation Codes
(in Canada). The appliance must be electrically grounded
in accordance with local codes or, in the absence of local
codes with the National Electric Code ANSI/NFPA No. 70
(in the United States), or to the CSAC22.1 Canadian Electric
Code (in Canada).
These models may be installed in a bedroom or bed-sitting
room in the U.S.A. and Canada.
7
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
Download from Www.Somanuals.com. All Manuals Search And Download.
Inspection
NOTE: The following requirements reference various
Massachusetts and national codes not contained in
this document.
The state or local gas inspector of the side wall horizontally
vented gas fueled equipment shall not approve the installa-
tion unless, upon inspection, the inspector observes carbon
monoxide detectors and signage installed in accordance with
the provisions of 248 CMR 5.08(2)(a)1 through 4.
Requirements for the Commonwealth of
Massachusetts
Exemptions
The following equipment is exempt from 248 CMR 5.08(2)(a)1
through 4:
For all side wall horizontally vented gas fueled equipment
installed in every dwelling, building or structure used in
whole or in part for residential purposes, including those
owned or operated by the Commonwealth and where the
side wall exhaust vent termination is less than seven (7)
feet above finished grade in the area of the venting, includ-
ing but not limited to decks and porches, the following
requirements shall be satisfied:
•
The equipment listed in Chapter 10 entitled “Equipment
Not Required To Be Vented” in the most current edition
of NFPA 54 as adopted by the Board; and
•
Product Approved side wall horizontally vented gas fu-
eled equipment installed in a room or structure separate
from the dwelling, building or structure used in whole or
in part for residential purposes.
Installation of Carbon Monoxide Detectors
At the time of installation of the side wall horizontal vent-
ed gas fueled equipment, the installing plumber or gasfit-
ter shall observe that a hard wired carbon monoxide de-
tector with an alarm and battery back-up is installed on
the floor level where the gas equipment is to be installed.
In addition, the installing plumber or gasfitter shall observe
that a battery operated or hard wired carbon monoxide
detector with an alarm is installed on each additional level
of the dwelling, building or structure served by the side
wall horizontal vented gas fueled equipment. It shall be
the responsibility of the property owner to secure the ser-
vices of qualified licensed professionals for the installa-
tion of hard wired carbon monoxide detectors.
MANUFACTURER REQUIREMENTS
Gas Equipment Venting System Provided
When the manufacturer of ProductApproved side wall hor-
izontally vented gas equipment provides a venting system
design or venting system components with the equipment,
the instructions provided by the manufacturer for installa-
tion of the equipment and the venting system shall include:
•
Detailed instructions for the installation of the venting
system design or the venting system components; and
•
A complete parts list for the venting system design or
venting system.
In the event that the side wall horizontally vented gas fu-
eled equipment is installed in a crawl space or an attic,
the hard wired carbon monoxide detector with alarm and
battery back-up may be installed on the next adjacent
floor level.
In the event that the requirements of this subdivision can
not be met at the time of completion of installation, the
owner shall have a period of thirty (30) days to comply
with the above requirements; provided, however, that dur-
ing said thirty (30) day period, a battery operated carbon
monoxide detector with an alarm shall be installed.
Gas Equipment Venting System NOT Provided
When the manufacturer of a Product Approved side wall
horizontally vented gas fueled equipment does not provide
the parts for venting the flue gases, but identifies “special
venting systems”, the following requirements shall be sat-
isfied by the manufacturer:
•
The referenced “special venting system” instructions shall
be included with the appliance or equipment installation
instructions; and
Approved Carbon Monoxide Detectors
•
The “special venting systems” shall be ProductApproved
by the Board, and the instructions for that system shall
include a parts list and detailed installation instructions.
Each carbon monoxide detector as required in accordance
with the above provisions shall comply with NFPA720 and
be ANSI/UL 2034 listed and IAS certified.
A copy of all installation instructions for all Product Ap-
proved side wall horizontally vented gas fueled equipment,
all venting instructions, all parts lists for venting instruc-
tions, and/or all venting design instructions shall remain
with the appliance or equipment at the completion of the
installation.
Signage
A metal or plastic identification plate shall be permanent-
ly mounted to the exterior of the building at a minimum
height of eight (8) feet above grade directly in line with the
exhaust vent terminal for the horizontally vented gas fu-
eled heating appliance or equipment. The sign shall read,
in print size no less than one-half (1/2) inch in size, “GAS
VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB-
STRUCTIONS”.
See Gas Connection section for additional Common-
wealth of Massachusetts requirements.
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
Download from Www.Somanuals.com. All Manuals Search And Download.
8
Getting Started
2
Introducing the Quadra-Fire Gas Appliances
WARNING: A HEARTH OR HEARTH EXTEN-
SION (IF PRESENT) MUST COMPLY WITH EI-
THER OF THE FOLLOWING: 1) THE SOLID-
!
Quadra-Fire direct vent gas appliances are designed to
operate with all combustion air siphoned from outside of
the building and all exhaust gases expelled to the outside.
FUEL BURNING FIREPLACE MANUFACTURER’S
SPECIFICATION, OR 2) LOCAL BUILDING CODES
REQUIRED BYAUTHORITY HAVING JURISDICTION.
The information contained in this Installers Guide, unless
noted otherwise, applies to all models and gas control
systems. Gas appliance diagrams, including the dimensions,
are shown in this section.
WARNING: THE SOLID FUEL FIREPLACE HAS
BEEN CONVERTED FOR USE WITH GAS
!
ONLY AND CANNOT BE USED FOR BURNING
WOOD OR SOLID FUELS UNLESS ALL ORIGINAL
PARTS HAVE BEEN REPLACED AND THE FIRE-
PLACE HAS BEEN REAPPROVED BY THE AUTHOR-
ITY HAVING JURISDICTION.
Pre-install Preparation
This gas insert fireplace and its components are tested
and safe when installed in accordance with this Installers
Guide. Report to your dealer any parts damaged in shipment,
particularly the condition of the glass. Do not install any
unit with damaged, incomplete, or substitute parts.
4. The solid fuel fireplace’s flue damper must be fully locked
in the open position or removed for installation.
The vent system components and trim surrounds are shipped
in separate packages. The gas logs are packaged
separately and must be field installed.
5. The chimney must be cleaned and in good working or-
der and constructed of noncombustible materials.
6. Make sure that all chimney cleanouts fit properly so air
cannot leak into the chimney.
Read all of the instructions before starting the instal-
lation. Follow these instructions carefully during the
installation to ensure maximum safety and benefit.
Failure to follow these instructions will void the own-
er’s warranty and may present a fire hazard.
7. To assure top performance, safety and efficiency, inserts
must be installed with an approved flue liner as per CAN/
CGA B-149 or National Fuel Code ANSI Z223 and these
instructions.
8. Install the insert without the trim surround and make all
gas, venting, and electrical connections.
The Hearth & Home Technologies Warranty will be voided
by, and Hearth & Home Technologies disclaims any
responsibility for, the following actions:
• Installation of damaged fireplace or vent system component.
• Modification of the fireplace or direct vent system.
• Installation other than as instructed by Hearth & Home
Technologies.
• Improper positioning of the gas logs or the glass door.
• Installation and/or use of any component part not manu-
factured and approved by Hearth & Home Technologies,
not withstanding any independent testing laboratory or other
party approval of such component part or accessory.
9. Install decorative trim surround. The surround is tested
AND approved with this gas insert AND may cover exist-
ing air circulation vents or grills on the solid fuel fireplace
into which it is installed. Should the surround not cover
all ventilation grill surfaces, the grill should be left open.
NOTE: DECORATIVE TRIM SURROUND HAS BEEN
TESTED AND APPROVED TO COVER EXISTING AIR
CIRCULATION VENTS OR GRILLS.
Only trim kit(s) supplied by the manufacturer shall
be used in the installation of this appliance.
ANYSUCHACTIONMAYPOSSIBLYCAUSEAFIREHAZARD.
VENTINGAND INSTALLATION
1. Village Collection gas inserts are designed for recessed in-
stallations into solid fuel masonry or factory built non-com-
bustible fireplaces that have been installed in accordance
with the National, Provincial, State and local building codes.
2. Minimum fireplace opening requirements are shown in
Figure 1 of this installation manual. The firebrick (refrac-
tory) can be removed from a factory built fireplace in or-
der to gain minimum gas insert opening requirements.
WARNING: Only the surround, as supplied,
may be used to cover integral grills on the
!
solid fuel burning fireplace. No other components
such as shrouds, sheet metal plates, etc. may be
used to seal off vents. Remote grills or openings
outside of the surround MUST NOT be covered or
sealed.
3. The metal floor of the solid fuel firebox may be removed
to facilitate the installation of the insert. CLEARANCE
TO COMBUSTIBLE MATERIAL UNDER THE INSERT
IS 1/4”. YOU MUST USE THE LEVELING LEGS TO
RAISE THE INSERT A MINIMUM OF 1/4” IF THE IN-
SERT IS TO SIT ON COMBUSTIBLE MATERIAL. The
side walls and top structure of the firebox may not be
altered with the exception of removable baffles and damp-
ers. The original fireplace may never be returned to solid
fuel in this condition.
If the factory built fireplace has no gas ac-
!
cess holes provided, an access hole of 1” di-
ameter (25mm) or less may be drilled through the
lower sides or bottom of the combustion cham-
ber in a proper workmanship like manner.
9
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
Download from Www.Somanuals.com. All Manuals Search And Download.
INLET AIR STARTING COLLAR
SURROUND
EXHAUST STARTING
COLLAR
DOOR
ON/OFF
SWITCH
GLASS
ASSEMBLY
RATING PLATE
GAS CONTROL
VALVE
ELECTRICAL JUNCTION
BOX ACCESS
GAS ACCESS
B
TOP VIEW
C
2”
(50.8mm)
A
QVI-30FB MINIMUM FIREPLACE SIZE
Location
Inches
Millimeters
A
B
C
*
Front Width
30-1/4
768
Rear Width
Depth
19
483
359
572
14-1/8
22-1/2
Height
* NOTE: If exhaust collar on insert and fireplace damper do not line up, add 4
inches (102mm) to minimum fireplace height for bends in vent pipe.
Figure 1.
Diagram of insert and minimum fireplace dimensions
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensions in brackets
are millimeters.
A
5-9/16
[142]
B
2-1/2
[64]
REF
4
2-1/16
[52]
[102]
13-3/4
[350]
3-1/8
[80]
C
ø 2-13/16 (2)
[71]
D
F
H
E
G
1-1/16
[28]
GAS INLET
ELECTRICAL
ACCESS
(IF EQUIPPED)
1-9/16
[40]
3-9/16
[91]
6-5/8
[169]
QVI-30FB MODEL DIMENSIONS
Location
Inches
Millimeters
A
B
C
D
E
F
18
457
6-1/2
29-3/8
26-1/16
20-5/8
14-5/8
22-1/8
21-1/4
165
746.1
661
524
371
G
H
562
540
Figure 2.
Diagram and model dimensions
11
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the Insert
3
A vertical vent termination system installed on this model
will require one (1) length of 3” stainless steel liner, one (1)
length of 3-inch flexible vent pipe for the combustion air,
one (1) length of 3-inch flexible vent pipe for the exhaust air
and one (1) Termination Cap.
Step 1. Installing the Vent System
Vent System Installation Precautions
Before starting installation of vent kits, the installer should
read these instructions and the Vent Kit Instructions to
ensure that a proper vent installation is completed.
NOTE: The damper of the existing chimney may need to be
removed to allow installation of the flexible-vent pipe.
Consult your local building codes before beginning the
installation.
WARNING: THIS FIREPLACE HAS BEEN
!
CONVERTED FOR USE WITH A GAS
FIREPLACE INSERT ONLYAND CANNOT BE USED
FOR BURNING WOOD OR SOLID FUELS UNLESS
ALL ORIGINAL PARTS HAVE BEEN REPLACED,
AND THE FIREPLACE REAPPROVED BY THE
AUTHORITY HAVING JURISDICTION.
WARNING: THIS GAS INSERT AND VENT AS-
SEMBLYMUST BE VENTED DIRECTLYTO THE
!
OUTSIDE AND MUST NEVER BE ATTACHED TO A
CHIMNEY SERVING A SEPARATE SOLID FUEL
BURNING APPLIANCE. EACH GAS APPLIANCE
MUST USEASEPARATE VENT SYSTEM. COMMON
VENT SYSTEMS ARE PROHIBITED.
NOTE: The above label, located in the instruction package,
must be affixed to the existing fireplace prior to installation.
Vent SystemApprovals
For zero clearance factory built woodburning fireplaces, the
use of kit LINK-ZC-ADPB in place of the standard square
flashing will allow you to mount the adaptor and cap on
class-A metal pipe.
Fireplace QVI30-FB is approved with vent termination kits
LINK-DV-30, LINK-DV-30B, LINK-DV4-30 and LINK-DV4-30B
as shown in Figures 4 & 5.Approved vent system termina-
tions are labeled for identification. 3-inch diameter listed
flexible aluminum and stainless steel gas vent is used for
both the incoming combustion air and exhaust vent pipes.
NO OTHER VENTING SYSTEMS OR COMPONENTS MAY
BE USED. Detailed installation instructions are included
with each vent termination kit and should be used in con-
junction with this manual.
Connecting the Vent Pipe
Install the 3” flexible vent pipe(s) down through the chimney.
Secure the end of the flexible vent pipe for exhaust to the
provided 3’ section of stainless steel flexible vent pipe.A3”
collar is factory installed on one end for mating the two
ends of flexible pipe.
Horizontal Venting
WARNING: THE 3’ SECTION OF STAINLESS
STEELFLEXIBLE PIPE MUST BEATTACHED DI-
RECTLY TO THE EXHAUST COLLAR OF THE UNIT.
!
The vent system on this model CANNOT be terminated
horizontally.
Vertical Venting
Attach either 4’ or 30’ section of intake liner to the intake
collar on the collar slide-plate using 3 screws. This assembly
may be removed from the unit to aid installation. Slide insert
into position, while pulling intake collar assembly towards
The vent pipes MUST be connected to the proper collars
on the unit AND the exhaust vent pipe MUST be connected
to the termination cap or the unit will not operate. The com-
bustion air vent pipe CAN be connected to the termination
cap (LINK -DV30, LINK -DV30B) or it can terminate inside
the chimney (LINK-DV4-30, LINK-DV4-30B). The bottom
opening of the chimney must be sealed around the vent
pipes if the combustion air vent is NOT connected to the
termination cap. See Figures 4 and 5.
the front of the unit.
Slide the gas insert into place, and
position any excess flexible vent pipe back up into the
This assembly will be secured in place when the
chimney.
pull handle can be secured into position.
NOTE: The minimum vertical rise (exhaust vent) is 14 feet
and the maximum vertical rise is 50 feet. These dimensions
are measured from the starting collars of the unit to the end
of the last section of vent pipe. See dimension V in Figure 4.
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
Download from Www.Somanuals.com. All Manuals Search And Download.
12
Attach the flashing and termination cap
to the top of the flexible vent pipe and set
the cap in place. See Figures 4 and 5.
HORIZONTAL OVERHANG
CAUTION: TO AVOID DOWNDRAFTS
AND/OR COLD AIR PROBLEMS, IT IS
RECOMMENDED TO SEAL OFF THE
AREA BETWEEN THE TERMINATION
CAP AND THE TOP OF THE SOLID-
FUEL CHIMNEY OPENING INTO
WHICH THE VENT CAP HAS BEEN IN-
STALLED.
VERTICAL WALL
2 FT.
MIN.
2 FT. MIN.
LOWEST
DISCHARGE
OPENING
TERMINATION CAP
X
WHEN USING THE LINK-DV4-30 VENT
SYSTEM, IT IS REQUIRED TO SEAL
AROUND THE FLEXIBLE VENT PIPES
IN THE DAMPER AREA. SEE FIGURE 4.
USE FIBERGLASS INSULATION OR
OTHER SUITABLE NON-COMBUSTI-
BLE MATERIAL.
12
ROOF PITCH IS X/ 12
H (MIN.) - MINIMUM HEIGHT FROM ROOF
TO LOWEST DISCHARGE OPENING
WARNING: MAJOR U.S.
BUILDING CODES SPECIFY
!
MINIMUM CHIMNEY AND/OR
VENT HEIGHT ABOVE THE ROOF
TOP. THESE MINIMUM HEIGHTS
ARE NECESSARY IN THE INTEREST
OF SAFETY. SEE THE FOLLOWING
DIAGRAM FOR MINIMUM HEIGHTS,
PROVIDED THE TERMINATION CAP
IS AT LEAST 2-FEET FROM A VER-
TICAL WALL AND 2-FEET BELOW
AHORIZONTAL OVERHANG.
Roof Pitch
H (min.) ft.
1.0
flat to 6/12
6/12 to 7/12
1.25
1.5
over 7/12 to 8/12
over 8/12 to 9/12
over 9/12 to 10/12
over 10/12 to 11/12
over 11/12 to 12/12
over 12/12 to 14/12
over 14/12 to 16/12
over 16/12 to 18/12
over 18/12 to 20/12
over 20/12 to 21/12
2.0
2.5
3.25
4.0
NOTE: This also pertains to vertical vent
systems installed on the outside of the
building.
5.0
6.0
7.0
7.5
8.0
Figure 3. Minimum Height from Roof to Lowest
Discharge Opening
13
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
Download from Www.Somanuals.com. All Manuals Search And Download.
This option shows both exhaust and inlet
air vent pipes attached to the adaptor.
TERMINATION
CAP
FLASHING
INLET AIR COLLAR
EXHAUST COLLAR
EXHAUST
VENT PIPE
V= 14 FT. MINIMUM
50FT. MAXIMUM
3 INCH COLLAR
(Factory installed to
stainless steel section)
WARNING: DO NOT
BLOCK PIPE END WITH
INSULATION OR ANY OTHER
SEALING MATERIAL
STAINLESS STEEL
PIPE - 3 FT. MIN.
REQUIRED (INCLUDED)
SEAL DAMPER
AREA
INLET AIR
VENT PIPE
COLLAR ATTACHMENT
BRACKET
Figure 4.
WARNING: THE EXHAUST VENT PIPE MUST
ONLY BE CONNECTED TO THE EXHAUST
STARTING COLLAR OF THE UNIT AND THE
CENTER COLLAR OF THE TERMINATION CAP.
THE INLET AIR PIPE MUST ONLY BE
CONNECTED TO THE INLET AIR COLLAR OF
THE UNIT AND EITHER ATTACHED TO THE
INLETAIR COLLAR OF THE TERMINATION CAP
OR TERMINATED IN THE CHIMNEY.
!
!
!
A 3 FOOT SECTION OF STAINLESS STEEL
FLEXIBLE LINER MUST BE ATTACHED
DIRECTLY TO THE EXHAUST COLLAR ON
COLLAR SLIDE PLATE.
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
Download from Www.Somanuals.com. All Manuals Search And Download.
14
Note: Inspect for exhaust
collar gasket to insure
positive exhaust seal.
LOCKING
TABS
ALTERNATIVE INSTALLATION
FOR VENTING THROUGH
WOOD-BURNING
CLASS A PIPE
LOCKING
HANDLE
TERMINATION
CAP
(SQUARE FLASHING
REMOVED)
EXHAUST VENT PIPE SUPPLIED
WITH TERMINATION KIT
INLET AIR VENT COLLAR
(LINK-DV30 SHOWN)
OPTIONAL
LINK-ZC-ADPB
(For Flashing Class-A Pipe)
SLIDING
PLATE
CLASS A
WOOD PIPE
INLET AIR VENT PIPE
3 INCH
COLLAR
STAINLESS STEEL
ADAPTER FOR EXHAUST
(MUST BE INSTALLED)
Figure 5. Typical configuration of vent liners.
15
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 2. Positioning, Leveling, and
Securing the Insert
Step 4. The Gas Supply Line
Remote Control
NOTE: Have the gas supply line installed in accordance
with local building codes by a qualified installer
approved and/or licensed as required by the locality.
(In the Commonwealth of Massachusetts installation
must be performed by a licensed plumber or gas
fitter).
The receiver for the remotes must be installed BETWEEN
the base pan of the insert and the firebox of the wood-burn-
ing fireplace (see photo below).
EXISTING SIDE
REFRACTORY
REMOTE
NOTE: Before the first firing of the fireplace, the gas
supply line should be purged of any trapped air.
RECEIVER
UNIT
NOTE: Consult local building codes to properly size
the gas supply line leading to the 1/2 inch (13 mm)
hook-up at the unit.
This gas fireplace is designed to accept a 1/2 inch
(13 mm) gas supply line. To install the gas supply line:
EXISTING BOTTOM
OFFIREPLACE
• A listed (and Commonweatlh of Massachusetts approved)
1/2 inch (13mm) tee-handle manual shut-off valve and a
listed flexible gas connector are connected to the 1/2
inch (13mm) inlet of the control valve. NOTE: If substi-
tuting for these components, please consult local codes
for compliance.
• Place the insert into position.
• Level the insert from side to side and from front to back.
Use the leveling legs if necessary to set each corner of
the base. The levelling legs are mounted behind the fan
cover plate. For location of fan cover plate, see Figure
11 on page 17.
• Locate the gas line access hole in the outer casing of
the fireplace.
• Insert the gas supply line through the gas line hole and
connect it to the shut-off valve.
Step 3. The Gas Control System
• When attaching the pipe, support the control so that the
lines are not bent or torn.
WARNING: THIS UNIT IS NOT FOR USE WITH
SOLID FUEL.
!
• After the gas line installation is complete, all connec-
tions must be tightened and checked for leaks with a
commercially-available, non-corrosive leak check solu-
tion. Be sure to rinse off all leak check solution following
testing.
These models use a standing pilot ignition type of gas con-
trol system.
Standing Pilot Ignition System
This system includes millivolt control valve, standing pilot,
thermopile/thermocouple flame sensor, and piezo ignitor.
WARNING: DO NOT USE AN OPEN FLAME TO
CHECK FOR GAS LEAKS.
!
WARNING: 110-120 VAC MUST NEVER BE
CONNECTED TO A CONTROL VALVE IN A
MILLIVOLT SYSTEM.
!
STANDING PILOT
GAS
SHUT-OFF
FLEXIBLE
GAS LINE
CONTROLS
Figure 6. Gas Controls System
Figure 7. Gas Supply Line
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
Download from Www.Somanuals.com. All Manuals Search And Download.
16
Step 5. Gas Pressure Requirements
WARNING: MUST USE THE CORD SUPPLIED
WITH THE J-BOX.
!
Pressure requirements for these gas appliances are shown
in the table below.
• This appliance REQUIRES 110-120 VAC to operate. It is
equipped with a blower.
Pressure
Natural Gas
Propane
NOTE: Electrical wiring must be installed by a li-
censed electrician.
Minimum
Inlet Pressure
5.0 inches
w.c.
11.0 inches
w.c.
CAUTION: DISCONNECT REMOTE CONTROLS IF AB-
SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE-
VENT ACCIDENTALAPPLIANCE OPERATION.
Maximum Inlet
Gas Pressure
14.0 inches
w.c.
14.0 inches
w.c.
Manifold
Pressure
3.5 inches
w.c.
10.0 inches
w.c.
For Standing Pilot Ignition Wiring
Appliance Requirements
Inlet and outlet pressure taps are provided on the front face
of the gas control for a test gauge connection to measure
the manifold pressure. Use a small flat blade screwdriver to
crack open the screw in the center of the tap. Position a
rubber hose over the tap to obtain the pressure reading.
WARNING: DO NOT CONNECT 110-120 VAC
TO THE GAS CONTROLVALVE OR THE WALL
SWITCH OR THE APPLIANCE WILL MALFUNC-
TIONAND THE VALVE WILL BE DESTROYED.
!
THE FIREPLACE AND ITS INDIVIDUAL SHUT-OFF
VALVE MUST BE DISCONNECTED FROM THE GAS
SUPPLY PIPING SYSTEMAND ISOLATED DURINGANY
PRESSURE TESTING OF THE SYSTEM AT TEST
PRESSURES EQUAL TO OR IN EXCESS OF ONE-HALF
(1/2) PSIG (3.5 KPA).
Wall Switch
Position the wall switch in the desired position on the wall.
An assembly of 18 ft of 20 AWG is provided with the appli-
ance to connect the wall switch to the appliance. Instead of
the supplied assembly, wire with a length of 25 ft or less and
a gauge of 20 AWG through 14 AWG is acceptable. The
wire needs a jacket with a temperature rating of 140oF (60oC)
or higher. At the appliance connect the wire to the ON/OFF
switch pigtails.
Step 6. Wiring the Fireplace
Use of the electrical junction box provided is required if
using a blower or remote. Plug the cord into a convenient
outlet. An electrician may install an outlet box inside the
fireplace. Place the outlet in the lower, back corner of the
fireplace. Make sure fan doesn’t touch back wall. Optional
remote controls are available and should be installed along
the side of the insert (see Step 2. Positioning, Leveling and
securing the Insert).
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPERAND DANGEROUS OPERATION.
VERIFY PROPER OPERATION AFTER SERVICING.
THERMOCOUPLE
THERMOPILE
ON
OFF
ROCKER
SWITCH
RED T1
GAS
VALVE
WHITE T2
OPTIONAL WALL SWITCH
THERMOSTAT OR REMOTE
Figure 8. Standing Pilot Ignition Wiring Diagram
17
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
Download from Www.Somanuals.com. All Manuals Search And Download.
To service or clean:
INSERT STRAIN RELIEF
AROUND CORD IN THIS END
FROM OUTSIDE OF UNIT
• Remove the ground wire of the fan can clip on the side of
the base pan.
FEED PLUG
THROUGH HOLE
SIDEWALL
• Remove the blower in between the bend up tabs.
• Install and wire the blower per instruction shipped with
the fan.
• Reinstall the blower in reverse order. Make sure the fan
does not make contact with the back wall.
JUNCTION
BOX
SCREW
PROVIDED
Figure 9.
Junction box installation
COVER
FAN
PLATE
Serving the blower
On units already installed removal of decorative front, sur-
round and gas insert is required.
• Detach flexible liner from the top of unit.
• Remove the four screws on the coverplate (see Figure 11).
• Bend up the tabs on the base pan (see Figure 10).
GROUND
WIRE
Figure 11.
REMOTE
RECEPTACLE
VARIABLE SPEED CONTROL
JUNCTION BOX
BLK
BLK
BLOWER RECEPTACLE
BLK
BLK
BLK
BLK
BLK
WHT
WHT
BLK
GROUND
BLOWER
TEMPERATURE
SENSOR SWITCH
BLK
GRN
WHT
110-120 VAC
REMOTE
OUTLET
FAN
JUNCTION
BOX
FAN
OUTLET
NOTE: IFANY OF THE ORIGINALWIRE AS SUP-
PLIED WITH THE APPLIANCE MUST BE RE-
PLACED, IT MUST BE REPLACED WITH TYPE
1050 C RATED WIRE.
TEMPERATURE
SENSOR SWITCH
SPEED CONTROL
(RHEOSTAT)
GROUND WIRE
(ATTACH TO ANY
METAL SURFACE)
BEND UP
TABS
Figure 10. Fan Wiring Diagram
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
Download from Www.Somanuals.com. All Manuals Search And Download.
18
Step 7. Installing Logs and Ember Material
BURNER PAN
Shutter Settings
Burner
NG
LP
___________________________________________
QVI-30FB
3/8”
Full Open
___________________________________________
Positioning the Logs
The logs have been packaged separately. Refer to the
installation instructions that accompany this manual. Save
the log instructions with this manual.
EMBER MATERIAL
(TOP SURFACE,
AND FRONT)
If sooting occurs, the logs or glowing embers might need
to be repositioned slightly to avoid excessive flame
impingement.
Î
Figure 13. Placement of the Ember Material
Placing the Ember Material
•
Place a dime size piece of GLOWING EMBER mate-
rial near port holes in burner top, sides and front (see
Figure 13).
Two separate bags of ember material are shipped with this
gas appliance. The bag labeled Glowing Ember (050-721)
is standard glowing ember material. To place the ember
material:
•
Space dime size ember pieces about a 1/2 inch apart.
Never press embers into burner ports. Do not cover burner
ports. Place dime size pieces around front and sides of
burner pan.
•
Remove the glass door from the unit (see Figure 12).
•
•
Save the remaining ember materials for use during fire-
place servicing. The embers provided are sufficient for 2
to 4 applications.
Place MYSTIC EMBERS over burner surface and around
base of the burner, do not cover any burner port holes.
Can be used on floor of firebox for a realistic ash-bed.
PULL AND
RELEASE
CLIPS TO OPEN
•
•
Replace the glass door on the fireplace.
Re-install and latch the decorative front.
Figure 12. Glass Assembly
Step 8. Installing Trim
Surrounds
Combustible materials MUST
NEVER overlap onto the front
face.
LOCATING
TABS
FIREBOX
1. Find the coiled low voltage wires
and ON/OFF switch attached to
outer right side of the insert (see
Figure 14).
2. Disconnect the ON/OFF switch
from the low voltage wire leads,
and insert the ON/OFF switch
through the hole at the upper
right corner of the surround - it
will be retained in the hole.
ON/OFF
SWITCH
SURROUND
WITH TRIM
Figure 14.
19
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Attach the low voltage wires to the ON/OFF switch lo-
cated on the front of surround.
Step 9. Before Lighting the Appliance
Before lighting the appliance, be sure to do the following:
Remove all paperwork from the fireplace.
Review safety warnings and cautions
4. Attach surround assembly by securing four corners with
screws provided (see Figure 14.) Reposition the fireplace
if necessary. Refer to surround instructions provided with
the decorative surround.
• Read the Safety and Warning Information section at
the beginning of this Installers Guide.
NOTE: PLACE THE THREE INSULATION PIECES INTO
THE CAVITIES AT THE BACK OF THE SURROUND BE-
FORE POSITIONING THE INSERT INTO THE FACTORY-
BUILT OR MASONRY FIREPLACE. THIS INSULATION
WILL HELP SEAL FOR COLD AIR LEAKS.
Double-check for gas leaks
• Before lighting the appliance, double-check the unit for
possible gas leaks.
Double-check vent terminations for obstructions.
• Before lighting the appliance, double-check the unit for
possible obstructions that could be blocking the vent ter-
minations.
Double-check for faulty components
12” MAX.
• Any component that is found to be faulty MUST BE re-
placed with an approved component. Tampering with the
appliance components is DANGEROUS and voids all war-
ranties.
MANTEL
A small amount of air will be in the gas supply lines. When
first lighting the appliance, it will take a few minutes for the
lines to purge themselves of this air. Once the purging is
complete, the appliance will light and will operate normally.
12” MIN.
Subsequent lightings of the fireplace will not require this
purging of air from the gas supply lines, unless the gas
valve has been turned to the OFF position, in which
case the air would have to be purged.
TOP OF
UNIT
NOTE: The fireplace should be run 3 to 4 hours on the initial
start-up. Turn it off and let it cool completely. Remove and
clean the glass. Replace the glass and run the fireplace for
an additional 8 hours. This will help to cure the products
used in the paint and logs.
During this break-in period it is recommended that some
windows in the house be opened for air circulation. This will
help avoid setting off smoke detectors, and help eliminate
any odors associated with the fireplace’s initial burning.
Figure 15
Figure 15 shows the minimum vertical and corresponding
maximum horizontal dimensions of mantels or other com-
bustible projections above the gas fireplace.
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
Download from Www.Somanuals.com. All Manuals Search And Download.
20
Step 10. Lighting the Appliance
unobstructed, and you’ve checked for faulty components.
Now you’re ready to light the appliance.
You’ve reviewed all safety warnings, you’ve checked the
appliance for gas leaks, you know the vent system is
LIGHTING INSTRUCTIONS
STANDING PILOT CONTROLS
FOR YOUR SAFETY
READ BEFORE LIGHTING
1. To access controls, open the lower grille.
WARNING: IF YOU DO NOT FOLLOW THESE
INSTRUCTIONS EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING
PROPERTYDAMAGE, PERSONALINJURY, OR
LOSS OF LIFE.
2. Turn the gas control valve knob to the OFF position. To do this, you
must turn the knob clockwise
press in and continue turning clockwise
to the PILOT position, and then
to the OFF position.
NOTE: Knob cannot be turned from “PILOT” to “OFF” unless knob is
pushed in slightly. Do not force.
3. WAIT AT LEAST FIVE (5) MINUTES TO CLEAR OUT ANY GAS. If
you have unsuccessfully tried to light the fireplace, wait longer, espe-
cially if you are using LP gas. Then smell for gas, including near the
floor. If you then smell gas, STOP! Follow "B" in the safety informa-
tion on previous page. If you don't smell gas, go to the next step.
STANDING PILOT IGNITION
A. This appliance (standing pilot version) has a pilot
that must be lighted by hand. When lighting the
pilot, follow these instructions exactly.
4. The pilot should not require accessing for lighting pur-
poses. The pilot is located inside the combustion chamber.
If it is necessary to access the pilot, remove the trim
door and glass door.
B. BEFORE LIGHTING smell all around the appli-
ance area for gas. Be sure to smell next to the
floor because some gas is heavier than air and
will settle to the floor.
THERMOCOUPLE PILOT THERMOPILE
5. To put the control in the PILOT position, turn the control knob counter-
clockwise
to the PILOT position.
6. To light the pilot press the control knob and then press the red or black
piezo button once every second. The piezo makes a clicking sound. It
may be necessary to repeat this step. If the pilot does not light after
10 seconds, go back to step 2. The control knob should be held down
for a MINUTE after pilot ignition.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any
phone in your building.
• If the control knob does not pop out when released, STOP! Shut off
the gas supply to the fireplace control valve, and IMMEDIATELY call
your service technician or gas supplier.
• Immediately call your gas supplier from a neigh-
bor’s phone. Follow the gas supplier’s instruc-
tions.
• If the pilot will not stay lit after two tries, turn the control knob to the
“OFF” position and call your service technician or gas supplier.
7. After the pilot has been lit, the burner can be turned on by turning the
• If you cannot reach your gas supplier, call the fire
department.
knob counter-clockwise
to the “ON” position.
8. Set the ON/OFF switch to the “ON” position.
9. Close the lower grille.
C. Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob will not
push in or turn by hand, don’t try to repair it, call
a qualified service technician. Force or attempt-
ed repair may result in a fire or explosion.
TO TURN OFF
GASAPPLIANCE
1. Open the lower grille.
D. Do not use this appliance if any part has been
under water. Immediately call a qualified service
technician to inspect the appliance and to replace
any part of the control system and any gas con-
trol which has been under water.
2. Set ON/OFF switch to “OFF”.
3. Turn the valve control knob clockwise
to the “Pilot” position,
then depress knob and continue turning to “OFF” position.
4. Close the lower grille.
Additionally, for the first few minutes after each lighting, vapor
may condense and fog the glass and flames may be blue.
After a few minutes this moisture will disappear and within
15-30 minutes the flames should become yellow.
When you light your fireplace, you may notice:
This gas appliance produces heat which does have an associ-
ated odor or smell. If you feel this odor is excessive it may
require the initial 3-4 hour continuous burn on high followed by
a second burn up to 12 hours to fully drive off any odor from
paint and lubricants used in the manufacturing process.
Noise caused by metal expanding and contracting as it heats
up and cools down, similar to the sound produced by a furnace
or heating duct. This noise does not affect the operation or
longevity of your fireplace.
During this break-in period it is recommended that some
windows in the house be opened for air circulation. This will
help avoid setting off smoke detectors, and help eliminate
any odors associated with the fireplace’s initial burning.
After the Installation
LEAVE THIS INSTALLATION MANUALWITH THE
APPLIANCE FOR FUTURE REFERENCE.
!
21
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintaining and Servicing YourAppliance
4
Appliance Maintenance
Although the frequency of servicing and maintenance will
depend on use and the type of installation, you should have
a qualified service technician perform an appliance check-
up at the beginning of each heating season. See the table
below for specific guidelines regarding each fireplace main-
tenance task.
IMPORTANT: TURN OFF THE GAS BEFORE SERVICING
YOUR FIREPLACE.
Replacing old ember material
Frequency: Once annually, during the checkup.
By: Qualified service technician.
MAKE SURE THE FLAMES
ARE STEADY—NOT
LIFTING OR FLOATING.
Task: Brush away loose ember material near the burner.
Replace old ember material with new dime-size and shape
pieces of Golden Ember (DE-93) and Glowing Ember (050-
721). New ember material should be placed alternately on
top of the burner - a layer of Golden Ember, a layer of
Glowing Ember, and so on. Save the remaining ember
material and repeat this procedure at your next servicing.
For more information, see Placing Ember Material.
Figure 16. Burner Flame Patterns
Checking Vent System
Frequency: Before initial use and at least annually
thereafter, more frequently if possible.
By: Qualified service technician/Home owner.
Task: Inspect the external vent cap on a regular basis to
ensure that no debris is interfering with the flow of air. Inspect
entire vent system for proper function.
Cleaning Burner and Controls
Frequency: Once annually.
By: Qualified service technician.
Task: Brush or vacuum the control compartment, fireplace
logs and burner areas surrounding the logs.
Checking Flame Patterns, Flame Height
Cleaning Glass Door
Frequency: After the first 3 to 4 hours of use. As neces-
sary after initial cleaning.
Frequency: Periodically.
By: Qualified service technician/Home owner.
Task: Make a visual check of your fireplace’s flame patterns.
Make sure the flames are steady - not lifting or floating.
See Figure 16. The thermopile/thermocouple (standing pilot)
tips should be covered with flame. See Figure 6.
By: Home owner.
Task: Remove and clean glass after the first 3 to 4 hours of
use. After the initial cleaning, clean as necessary, particu-
larly after adding new ember (flame colorant) material. Film
deposits on the inside of the glass door should be cleaned
off using a household glass cleaner. NOTE: DO NOT handle
or attempt to clean the door when it is hot and DO
NOT use abrasive cleaners.
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
Download from Www.Somanuals.com. All Manuals Search And Download.
22
With proper installation, operation, and maintenance your gas fireplace will
provide years of trouble-free service. If you do experience a problem, this
troubleshooting guide will assist a qualified service person in the diagnosis
of a problem and the corrective action to be taken. This troubleshooting
guide can only be used by a qualified service technician.
Troubleshooting
5
Symptom
Possible Cause
Corrective Action
1. After repeated
triggering of the red
or black piezo button,
the spark ignitor will
not light the pilot.
a. Defective ignitor.
Check the spark at the electrode and pilot. If no spark and electrode wire is
properly connected, replace the ignitor.
b. Defective pilot or
misaligned electrode
(spark at electrode).
Using match, light the pilot. If the pilot lights, turn off the pilot and trigger the red or
black piezo button again. If the pilot lights, an improper gas/air mixture caused the
bad lighting and a longer purge period is recommended. If the pilot will not light,
ensure the the gap at the electrode and pilot is one-eighth (1/8) inch to have a
strong spark. If the gap is OK, replace the pilot.
c. No gas or low gas
pressure.
Check the remote shut-off valvess from the fireplace. Usually, there is a valve near
the gas main. There can be more than one (1) valve between the fireplace and the
main.
d. No LP in tank.
Check the LP (propane) tank. You may be out of fuel.
2. The pilot will not
stay lit after carefully
following the lighting
instructions.
a. Defective
thermocouple.
Check that the pilot flame impinges on the thermocouple. Clean and/or adjust the
pilot for maximum flame impingement.
Ensure that the thermocouple connection at the gas valve is fully inserted and tight
(hand tighten plus 1/4 turn).
Disconnect the thermocouple from the valve, place one millivolt meter lead wire on
the tip of the thermcouple and the other meter lead wire on the thermocouple
copper lead. Start the pilot and hold the valve knob in. If the millivolt reading is less
than 15mV, replace the thermocouple.
b. Defective valve.
If the thermocouple is producing more than 15 millivolts, replace faulty valve.
3. The pilot is
a. ON/OFF switch or
wires defective.
Check the ON/OFF switch and wires for proper connections. Place the jumper
wires across the terminals at the switch. If the burner comes on, replace the
defective switch. If the switch is OK, place the jumper wires across the switch wires
at the gas valve. If the burner comes on, the wires are faulty or connections are
bad.
burning, there is no
gas burner, the valve
knob is in the ON
position, and the
ON/OFF switch is in
the ON position.
b. Thermopile may
not be generating
sufficient millivoltage.
If the pilot flame is not close enough physically to the thermopile, adjust the pilot
flame.
Be sure the wire connections from the thermopile at the gas valve terminals are
tight and that the thermopile is fully inserted into the pilot bracket.
Check the thermopile with a millvolt meter. Take the reading at TH-TP&TP
terminals of the gas valve. The meter should read 325 millivolts minimum, while
holding the valve knob depressed in the pilot position, with the pilot lit, and the
ON/OFF switch in the OFF position. Replace the faulty thermopile if the reading is
below the specified minimum.
With the pilot in the ON position, disconnect the thermopile leads from the valve.
Take a reading at the thermopile leads. The reading should be 325 millivolts
minimum. Replace the thermopile if the reading is below the minimum.
c. Defective valve.
Turn the valve knob to the ON position. Place the ON/OFF switch in the ON
position. Check the millivolt meter a the thermopile terminals. The millivolt meter
should read greater than 125mV. If the reading is acceptable, and if the burner
does not come on, replace the gas valve.
d. Plugged burner
orifice.
Check the burner orifice for stoppage. Remove stoppage.
e. Wall switch or
wires are defective.
Follow the corrective action in Symptom and Possible Cause 1.a above. Check
the switch and wiring. Replace where defective.
23
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting (continued)
Symptom
Possible Cause
Corrective Action
4. Frequent pilot
outage problem.
a. Pilot flame may be too high or
too low, or blowing (high),
Clean and adjust the pilot flame for maximum flame impingement on
thermocouple. Follow lighting instructions carefully.
causing pilot safety to drop out.
5. The pilot and main a. No LP in tank.
Check the LP (propane) tank. Refill the fuel tank.
burner extinguish
while in operation.
b. Inner vent pipe leaking exhaust Check for gas leaks.
gases back into the system.
c. Glass too loose and air tight
packet leaks in corners after
usage.
Tighten the corner.
d. Bad thermopile or
thermocouple.
Replace if necessary.
e. Improper vent cap installation.
a. Flame impingement.
Check for proper installation and freedom from debris or blockage.
Adjust the log set so that the flame does not excessively impinge on it.
Adjust the air shutter at the base of the burner.
6. Glass soots.
b. Improper venturi setting.
c. Debris around venturi.
Inspect the opening at the base of the burner. NO MATERIAL SHOULD
BE PLACED IN THIS OPENING.
7. Flame burns blue
and lifts off burner.
a. Insufficient oxygen being
supplied.
Ensure that the vent cap is installed properly and free of debris. Ensure
that the vent system joints are tight and have no leaks.
Ensure that no debris has been placed at the base of, or in the area of
the air holes in the center of the base pan beneath the burner.
Ensure that the glass is tightened properly on the unit, particularly on top
corners.
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
Download from Www.Somanuals.com. All Manuals Search And Download.
24
Lifetime Warranty
LIMITED LIFETIME WARRANTY
The Hearth & Home Technologies limited Lifetime Warranty guarantees that the following components will work as
designed for the lifetime of the stove or Hearth & Home Technologies will repair or replace them. These items
include but are not limited to steel and cast iron components, all gas burners, gas logs, combustion chambers,
heat exchanger systems, stainless steel firebox components, plating, doors, glass damaged by thermal breakage,
steel baffle supports, steel and ceramic baffles and manifold tubes. Labor is for the first five years.
THREE YEAR WARRANTY
Our EZ Clean firepots are covered under Hearth & Home Technologies three-year warranty program. Labor is for
3 years.
TWO YEAR WARRANTY
All electrical components such as but not limited to blowers, wiring, vacuum switches, speed controls, control
boxes, thermodisc switches, igniters, pilot assembly, gas valves, thermostats and remotes are covered under
Hearth & Home Technologies two-year warranty program. Effective April, 2005 igniters are also covered under the
two year warranty. Labor is for two years.
ONE YEAR WARRANTY
Porcelain and powdercoat finishes are warranted against manufacturer defects for one year. Labor to repair or
replace these parts is covered for one year, reimbursed per our warranty service fee schedule.
CONDITIONS
This warranty is nontransferable and is made to the original retail purchaser only provided that the purchase was
made through an authorized dealer of Hearth & Home Technologies. It must be installed and operated at all times
in accordance with the Installation and Operating Instructions furnished with this product, as well as any applicable
local and national codes. Any alteration, willful abuse, accident, or misuse of the product shall nullify this warranty.
Labor to repair or replace items covered under the limited Lifetime Warranty will be covered for the first five years per
our warranty service fee reimbursement schedule. Parts covered under the limited Lifetime Warranty will be covered
for the lifetime of the appliance up to a maximum of ten (10) years after Hearth & Home Technologies discontinues
the model and two
(2) years for optional accessories. Adjustments, regular maintenance, cleaning and temporary repairs do not
qualify for a service call fee and will not be covered. The replacement of consumer replaceable items and installation
of upgraded component parts do not quality for a service call fee, and will not be covered.
This limited Lifetime Warranty does not extend to or include surface finish on the appliance, door gasketing, glass
gasketing, glass, firebrick, pellet logs, kaowool or other ceramic insulating materials. It does not cover installation
or operational-related problems such as overfiring, use of corrosive driftwood, downdrafts or spillage caused by
environmental conditions, nearby trees, buildings, hilltops, mountains, inadequate venting or ventilation, excessive
offsets, or negative air pressures caused by mechanical systems such as furnaces, fans, clothes dryers, etc.
Any installation, construction, transportation, or other related costs or expenses arising from defective part(s),
repair, replacement, etc., will not be covered by this warranty, nor will Hearth & Home Technologies assume
responsibility for them. Further, Hearth & Home Technologies will not be responsible for any incidental, indirect, or
consequential damages, except as results in damage to the interior or exterior of the building in which this appliance
is installed. This limited Lifetime Warranty does not apply to the venting components, hearth components or other
accessories used in conjunction with the installation of this product not manufactured by Hearth & Home
Technologies
This warranty is void if the stove has been overfired or operated in atmospheres contaminated by chlorine, fluorine,
or other damaging chemicals, the stove is subjected to prolonged periods of dampness or condensation, or there
is any damage to the stove or other components due to water or weather damage which is the result of, but not
limited to, improper chimney or venting installation. Hearth & Home Technologies may, at its discretion, fully
discharge all obligations with respect to this warranty by either repairing or replacing the unit, or refunding the
wholesale price of the defective part(s).
This limited Lifetime Warranty is effective on all appliances sold after May 1, 2002 and supersedes any and all
warranties currently in existence.
250-8620J
12/05
25
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07