Chapter 1: Introduction
•
•
•
•
•
About This Manual (below)
Thank you for purchasing Promise Technology’s VTrak J610s or J310s external
disk array subsystem.
About This Manual
This Product Manual describes how to setup, use and maintain the VTrak J610s
or J310s external disk subsystem. It also describes how to use the built-in
command-line interface (CLI) software.
This manual includes a full table of contents, index, chapter task lists and
numerous cross-references to help you find the specific information you are
looking for.
Also included are four levels of notices:
Note
A Note provides helpful information such as hints or alternative
ways of doing a task.
Important
An Important calls attention to an essential step or point required
to complete a task. Important items include things often missed.
Caution
A Caution informs you of possible equipment damage or loss of
data and how to avoid them.
Warning
A Warning notifies you of probable equipment damage or loss of
data, or the possibility of physical injury, and how to avoid them.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
Overview
The Promise VTrak J610s and J310s are optimized for organizations deploying
cost-effective small-to-medium application clusters, disk-to-disk backup and
midrange storage solutions.
Figure 1. VTrak J610s front view with bezel removed
Drive Carrier LEDs
Drive Carriers
Power and Status LEDs
Figure 2. VTrak J310s front view with bezel removed
Drive Carrier LEDs
Drive Carriers
Power and Status LEDs
The dual 3Gb SAS host interface ports offer the ease of management and
performance required by companies running popular departmental and back-
office applications including file/print, e-mail, database and Web services
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1: Introduction
Figure 3. VTrak J610s rear view
I/O module 1
I/O module 2
115200
115200
8
N
1
8
N
1
Power Supply 2
Power Supply 2
Power Supply 1 Cooling Unit 1 Cooling Unit 2
Figure 4. VTrak J310s rear view
Power Supply 1 Cooling Unit 1 Cooling Unit 2
O
I
O
I
115200
115200
8
N
1
8
N
1
I/O module 1
I/O module 2
The two external SAS ports provide the needed connectivity and bandwidth for
large capacity solutions requiring multiple JBOD boxes cascaded together while
still providing dual server support and host port failover or aggregation.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
Architectural Description
The VTrak J610s packs up to 16 drives per system, offering industry-leading
capacity in just 3U of standard 19-inch rack space. The VTrak J310s supports up
to 12 drives per system, in just 2U of standard 19-inch rack space. The J610s
and J310s unit’s compact form factor maximizes density, increasing capacity per
unit of rack space.
Multiple J610s and J310s systems can also be connected to the same server
using standard SAS features to deliver massive storage to capacity hungry
applications such as disk-to-disk backup, media archiving, video surveillance and
compliance storage
Promise has designed the J610s and J310s chassis to be fully compatible with all
future Promise external storage products. By using the same chassis, drive
carriers, and cooling units, upgrading the RAID controllers and JBOD modules is
fast and simple.
With the VTrak J610s and J310s, Promise has dramatically narrowed the gap
between simple fault tolerance and No Single Point of Failure. The VTrak J610s
and J310s use a fully redundant, hot-swap design and continuously monitors all
system components. It can withstand failures to disks, power supplies, cooling
and I/O modules without interrupting system operation.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1: Introduction
Features and Benefits
Feature
Benefit
3U or 2U 19-inch wide enclosure
Installs easily in any standard rackmount.
Supports Serial Attached SCSI
disk drives
Allows you to use the new dual-port SAS
disk drives.
Supports Serial ATA disk drives
Allows you to use your legacy SATA disk
drives.
Hot-swap feature for drive carriers, Allows a defective component to be
I/O modules, power supplies and replaced without interrupting data
fans
accessibility to the host system.
Tool-less field-replaceable units
(FRUs)
All FRUs can be replaced without tools,
saving time and effort for support personnel.
Complete cable-less design
All components easily plug directly into
boards. No cables to complicate setup or
maintenance.
Redundant, hot-swappable cooling Load sharing and full operation even with
units multiple failed fans.
Redundant, hot-swappable power Load sharing and full operation even with a
supplies
failed power supply.
Dual, active/active I/O Modules
High level of availability even with a failed
I/O module.
One host SAS port per I/O module Two I/O modules are needed to set up
clustering.
One expansion SAS port I/O
module
Enables cascading JBOD subsystems.
Command-line interface
Control and monitoring with simple,
straightforward interface.
Management through in-band SAS Choice of local or network management
or serial port options
Compatible with leading SAS HBA Easy, works-the-first-time connections with
and RAID cards your current systems
5
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
Specifications
Drive Capacity: J610s, 16 drives. J310s, 12 drives.
External I/O Ports: SAS host port and SAS expansion port.
Supported Disk Interfaces: Serial Attached SCSI (SAS) and Serial ATA (SATA),
3Gb/s and 1.5Gb/s
Supported Operating Systems:
•
Windows Vista, Business,
Enterprise, or Ultimate
•
•
•
•
RedHat Linux
SuSE Linux
•
•
•
Windows 2003 Server
Windows XP Professional
Windows 2000
Novell Netware
Sun Solaris
The list above refers to 32-bit and 64-bit versions of the OS in the Host PC or
server. The actual OS support depends upon your SAS HBA or RAID
adapter. Check your SAS HBA or RAID adapter user documentation.
Voltage: 100–240 VAC Auto-ranging.
Current: 8 A @ 100 VAC; 4 A @ 240 VAC Current rating with two power cords
Power Consumption (not including disk drives):
J610s, 108.38 W.
J310s, 100.87 W.
Power Consumption (including disk drives):
J610s, 523.91 W.
J310s, 412.51 W.
Power Supply:
J610s, Dual 500W, 100–240 VAC auto-ranging, 50–60 Hz, dual hot swap and
redundant with PFC, N+1 design.
J310s, Dual 400W, 100–240 VAC auto-ranging, 50–60 Hz, dual hot swap and
redundant with PFC, N+1 design.
Operating Temperature:
5° to 40°C operational
-40° to 60°C non-operational
Relative Humidity: Maximum 95%
Vibration: Random, 0.21 grms, 5 to 500 Hz, 30 Mins, X, Y, Z axis
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1: Introduction
Dimensions (H x W x D):
J610s, 13.1 x 44.7 x 56.1 cm (5.2 x 17.6 x 22.1 in)
J310s, 8.8 x 44.7 x 56.1 cm (3.5 x 17.6 x 22.1 in)
Net Weight:
J610s, 30.5 kg (67.2 lb) without drives, 38.5 kg (84.9 lb) with 16 drives, assuming
0.5 kg (1.1 lb) per drive.
J310s, 26.5 kg (58.4 lb) without drives, 32.5 kg (71.7 lb) with 12 drives, assuming
0.5 kg (1.1 lb) per drive.
Gross Weight (including carton):
J610s, 37.5 kg (82.7 lb) without drives.
J310s, 33.0 kg (72.8 lb) without drives.
Safety: CE, FCC Class A, VCCI, C-Tick, cUL, TUV, CB, BSMI, MIC.
Warranty and Support
Warranty: Three years complete system limited warranty.
Support: 24x7 email and phone support (English only). 24x7 access to Promise
support site for drivers, firmware, and compatibility.
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
CE Statement
Warning: This is a class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take
adequate measures.
MIC Statement
7
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2: Installation
•
•
•
•
•
•
•
•
Unpacking the VTrak (below)
Unpacking the VTrak
The VTrak J610s or J310s box contains the following items:
•
•
•
•
VTrak J610s or J310s Unit
Quick Start Guide
•
Screws for disk drives
(J610s: 70, including 6 spares)
(J310s: 50, including 2 spares)
Front bezel and key
•
•
•
•
Left and right mounting rails
RJ11-to-DB9 serial data cable
(Units with one I/O module: 1)
(Units with two I/O modules: 2)
Left and right center-mount brackets
1.5m (4.9 ft) Power cords (2)
•
1.0m (3.3 ft) SAS cable
CD with Product Manual and Quick
(Units with one I/O module: 1)
(Units with two I/O modules: 2)
Start Guide
Warning
The electronic components within the J610s and J310s units are
sensitive to damage from Electro-Static Discharge (ESD).
Observe appropriate precautions at all times when handling the
J610s or J310s unit or its subassemblies.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
Figure 1. VTrak J610s rear view
I/O module 1
I/O module 2
115200
115200
8
N
1
8
N
1
Power Supply 2
Power Supply 2
Power Supply 1 Cooling Unit 1 Cooling Unit 2
Figure 2. VTrak J310s rear view
Power Supply 1 Cooling Unit 1 Cooling Unit 2
O
I
O
I
115200
115200
8
N
1
8
N
1
I/O module 1
I/O module 2
Some J610s and J310s units ship with a single I/O module and a blank unit
installed in the place of the second I/O module. You can upgrade your J610s or
Some J610s and J310s units ship with a single power supply and an auxiliary
cooling unit installed in the place of the second power supply to provide a
comparable level of air circulation inside the enclosure.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2: Installation
Mounting VTrak J610s in a Rack
The J610s subsystem installs to the rack using the supplied mounting rails. You
can also use your existing rails.
Figure 3. VTrak J610s mounted in a rack with the supplied rails
Vertical Rack Post
VTrak J610s
Mounting rails (included)
mount outside the rack post
Handles mount
outside the rack post
Cautions
•
•
At least two persons are required to safely lift, place, and
attach the VTrak subsystem into a rack system.
Do not lift or move the VTrak subsystem by the handles,
power supplies or the controller units. Hold the subsystem
itself.
•
•
•
Do not install the VTrak subsystem into a rack without rails to
support the subsystem.
Only a qualified electrician who is familiar with the installation
procedure should mount and install the VTrak subsystem.
Be sure all switches are OFF before installing the VTrak
subsystem or exchanging components.
To install the J610s subsystem into a rack with the supplied mounting rails:
1. Check the fit of the mounting rails in your rack system. See Figure 4.
2. Adjust the length of the mounting rails as needed.
3. Attach the mounting rail assemblies to the outside of the rack posts, using
the attaching screws from your rack system.
Be sure the support is on the bottom facing inward.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
4. Square the rail assemblies in the rack.
5. Tighten the adjustment screws and the attaching screws.
6. Place the VTrak subsystem onto the rails.
7. Secure the VTrak subsystem to the rack through each handle, using the
attaching screws from your rack system.
Figure 4. Rack mount assembly diagram
Rack front post
Rack back post
Rail attaching screw
(not included)
Rail attaching screw
(not included)
Front rail
Rear rail
Flange
Support
Rail adjustment screw
Rail adjustment screw
Inside of post
Inside of post
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2: Installation
Mounting VTrak J310s in a Rack
The J310s subsytem installs to the rack using the supplied mounting rails. You
can also use your existing rails.
Figure 5. VTrak J310s mounted in a rack with the supplied rails
VTrak J310s
Vertical Rack Post
Handles mount
outside the rack post
Mounting rails (included)
mount outside the rack post
Cautions
•
•
At least two persons are required to safely lift, place, and
attach the VTrak subsystem into a rack system.
Do not lift or move the VTrak subsystem by the handles,
power supplies or the controller units. Hold the subsystem
itself.
•
•
•
Do not install the VTrak subsystem into a rack without rails to
support the subsystem.
Only a qualified electrician who is familiar with the installation
procedure should mount and install the VTrak subsystem.
Be sure all switches are OFF before installing the VTrak
subsystem or exchanging components.
To install the VTrak subsystem into a rack with the supplied mounting rails:
1. Check the fit of the mounting rails in your rack system. See Figure 7.
2. Slide the plates out of the mounting rails.
3. Attach one plate to each side of the VTrak subsystem.
Line-up the six holes in the plate with the corresponding holes in the
subsystem. Attach each plate with six screws (included). See Figure 6.
4. Slide one of the rails over the plate on one side of the enclosure.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
The rail is designed to slide freely over the plate.
5. Attach a flange to each end of the rail, with the rail on the opposite side of
the flange from the two-hole bracket.
6. Install the rail adjustment screws (included) through the flange into the rail.
There are four screws for each flange. See Figure 7.
7. Place the subsystem with mounting rails into your rack system.
8. Attach the mounting rail assemblies to the outside of the rack posts, using
the attaching screws from your rack system.
9. Square the rail assemblies in the rack.
10. Tighten the adjustment screws and the attaching screws.
11. Place the VTrak subsystem onto the rails.
12. Secure the VTrak subsystem to the rack through each handle, using the
attaching screws from your rack system.
Figure 6. Sliding flange installation
Rear (connector end)
of the subsystem
VTrak J310s
Sliding plate
Screws (6 each side)
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2: Installation
Rack back
Figure 7. Mounting rail installation
Rack front post
Rail adjustment screw
Mounting Rail
Sliding plate
Rail attaching screw
(not included)
Rail attaching screw
(not included)
Inside of post
Inside of post
15
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
Installing Disk Drives
Populate the VTrak with 3.5-inch SAS or SATA disk drives.
Install all of the drive carriers into the J610s or J310s enclosure to ensure proper
airflow, even if you do not populate all the carriers with disk drives.
Caution
Use only the counter-sink screws supplied with the J610s or J310s
unit. Use of other types of screws can damage the adjacent
drives.
Figure 8. J610s and J310s unit drive carrier mounting holes
AAMUX
Disk Drive Mounting Holes
Mounting Holes with AAMUX
Disk Drive Mounting Holes
without AAMUX
1. Remove the front bezel (drive door).
2. Remove a disk drive carrier.
3. Optional. The AAMUX adapter is recommended for J610s and J310s
enclosures with two I/O modules, so that both modules can access a SATA
disk drive.
Place the optional AAMUX into the disk drive carrier and attach it with the
four screws.
•
•
Install only the screws supplied with the AAMUX.
The AAMUX fits into the carrier with the SAS connector at the back. See
Figure 6 on page 18
•
Snug each screw. Be careful not to over tighten.
4. Carefully lay the drive into the drive carrier at the front, so that the screw
holes on the bottom line up.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2: Installation
If you installed an AAMUX, lay the SATA disk drive in the carrier and slide it
so the power and data connectors insert in to the AAMUX. See Figure 10 on
5. Insert the screws through the holes in the drive carrier and into the bottom of
the disk drive (see Figure 5).
•
•
•
Install only the screws supplied with the VTrak.
Install four screws per drive.
Snug each screw. Be careful not to over tighten.
6. Reinstall the drive carrier into the VTrak chassis.
7. Repeat steps 2 through 5 until all of your disk drives are installed.
8. Replace the front bezel.
Figure 9. Drive carrier with SAS disk drive
SAS Disk Drive
17
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
Figure 10.Drive carrier with SATA disk drive and AAMUX
SATA Disk Drive
AAMUX adapter
Cautions
SAS connector
•
•
If you plan to operate your VTrak with fewer than a full load of
disk drives, install all of the drive carriers into the enclosure, to
ensure proper airflow for cooling.
A VTrak J610s or J310s carrier is similar in appearance but is
NOT interchangeable with a VTrak M500f/i/p drive carrier.
Important
Be sure each drive is securely fastened to its carrier. Proper
installation ensures adequate grounding and minimizes vibration.
Do not install drives with fewer than four screws.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2: Installation
Drive Numbering
Each disk drive in the J610s and J310s units is identified by a number that
corresponds to the Port number used for management. See “Link Command” on
Numbers are stamped above each drive bay for easy indentification.
Figure 11.VTrak J610s drive slot numbering
1
2
3
4
8
5
6
7
9
10
11
12
13
15
14
16
Figure 12.VTrak J310s drive slot numbering
4
1
2
3
8
5
6
7
12
9
10
11
19
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
Setting Up Data Cable Connections
The VTrak J610s or J310s unit provides Direct Attached Storage (DAS) support
to the Host PC.
Figure 13. VTrak J610s has one or two I/O modules
I/O module 1
(default primary)
I/O module 2
115200
115200
8
N
1
8
N
1
Figure 14.VTrak J310s has one or two I/O modules
O
I
O
I
115200
115200
8
N
1
8
N
1
I/O module 1
(default primary)
I/O module 2
There can be one or two Input Output Modules (I/O modules) on the J610s or
J310s unit.
•
If your J610s or J310s has two I/O modules, I/O module 1 (on the left) is the
default primary.
•
If your J610s or J310s has only one I/O module, that I/O module is the
default primary.
Under SAS specifications, both I/O modules are active at the same time. The
terms primary and secondary are for enclosure management purposes only. To
verify which I/O module is the default primary, see “Enclosure Command” on
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2: Installation
Figure 15.VTrak J610s and J310s I/O modules have one subtractive-routed
port and one table-routed port
115200
8 N 1
Subtractive Connector (CN2) LED
Table Connector (CN1) LED
I/O Module Status LED
Each I/O module has one table-routed external receptacle (CN1) and one
subtractive-routed external receptacle (CN2).
Note
SAS HBA cards are User-supplied items. They are not included
with the VTrak unit.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
Basic DAS Connection
Figure 16. An example of a basic DAS connection between one Host PC
and one VTrak J310s unit. The J610s is similar
Subtractive-Routed Port
O
I
O
I
115200
115200
8
N
1
8
N
1
VTrak J310s
SFF-8088 external
4X to 4X SAS cable
SAS HBA Card
PC
The arrangement above is the minimum DAS system with a single SAS HBA
card in the Host PC. Connect the SAS card to the subtractive-routed port (CN2)
on the I/O module.
Use a SFF-8088 4X to 4X external SAS cable with thumbscrew connectors
(supplied with the J610s or J310s unit).
Because the Host SAS HBA card is an end device, you can connect it to either of
the two SAS ports (CN1 or CN2) on the J610s or J310s unit’s I/O module.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2: Installation
Cascading DAS Connection
If you are using multiple J610s or J310s units and want to manage them from the
same SAS HBA card, connect the J610s or J310s units in a cascade.
Connect the SAS HBA card in the Host PC to the subtractive-routed port (CN2)
of the I/O module. Use a SFF-8088 4X to 4X external SAS cable (supplied with
the J610s or J310s unit).
Connect the I/O module’s table-routed port (CN1) on the first J610s or J310s unit
to the subtractive-routed port (CN2) on the next J610s or J310s unit.
You can cascade up to four J610s or J310s units in this manner. You can mix
J610s and J310s units in the same cascade.
Figure 17. An example of a cascaded DAS connection between one Host
PC and two VTrak J310s units. The J610s is similar
SAS HBA Card
PC
CN1
CN2
O
I
O
I
115200
115200
8
N
1
8
N
1
CN2
VTrak J310s
O
I
O
I
115200
115200
8
N
1
8
N
1
VTrak J310s
23
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
Redundant DAS Connection
The arrangement below is a DAS system with full redundancy.
Figure 18. An example of a redundant DAS connection between two Host
PCs and four cascaded VTrak J310s units. The J610s is similar
SAS HBA Cards
PC
PC
CN2
O
I
O
I
CN1
CN2
115200
115200
8
N
1
8
N
1
VTrak J310s
O
I
O
I
CN1
CN2
115200
115200
8
N
1
8
N
1
VTrak J310s
O
I
O
I
CN1
CN2
115200
115200
8
N
1
8
N
1
VTrak J310s
O
I
O
I
115200
115200
8
N
1
8
N
1
VTrak J310s
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2: Installation
The arrangement requires J610s or J310s units with dual I/O modules and two
Host PCs with a SAS HBA card in each PC.
Connect the SAS HBA card in the first Host PC to the subtractive-routed port
(CN2) on an I/O module of the first J610s or J310s unit.
Connect the SAS HBA card in the second Host PC to the subtractive-routed port
(CN2) on the other I/O module of the first J610s or J310s unit.
Connect the table-routed ports (CN1) on the I/O modules of the first J610s or
J310s unit to the subtractive-routed ports (CN2) on the I/O modules of the next
J610s or J310s unit.
Connect the remaining J610s or J310s units in the same manner. You can mix
J610s and J310s units in the same cascade.
Use SFF-8088 to SFF-8088 SAS cables to connect the J610s or J310s units.
Setting Up Serial Cable Connections
RS232 serial communication enables the Command Line Interface (CLI) and
Command Line Utility (CLU) on your PC to monitor and control the VTrak. On
VTrak, RS232 communication goes through the RJ11 serial connector on each
controller.
Figure 19. A serial connector is located on the I/O module. The J310s is
shown. The J610s is similar
RJ11Serial
Connector
115200
8
N
1
O
I
O
I
115200
115200
8
N
1
8
N
1
To set up a serial cable connection:
1. Attach the RJ11 end of the RJ11-to-DB9 serial data cable, supplied with the
VTrak, to the RJ11 serial connector on one of the I/O modules.
2. Attach a null-modem cable to the DB9 end of the RJ11-to-DB9 serial data
cable.
3. Attach the other end of the null-modem cable to a serial port on the Host PC
or Server.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
If your PC has two DB9 COM ports, and your J610s or J310s unit has two I/O
modules, you can connect a second null-modem cable and RJ11-to-DB9 serial
data cable the I/O module on the right.
I/O module is the default primary. To verify which I/O module is the default
primary, see “Enclosure Command” on page 34.
Connecting the Power
Plug the power cords and switch on both power supplies. When the power is
switched on, the LEDs on the front of the VTrak will light up.
Figure 20.VTrak J310s front panel LED display. The J610s is similar
Power
FRU Status
Not Used
I/O module-1 activity
I/O module-2 activity
Heartbeat
When boot-up is finished and the VTrak is functioning normally:
•
The heartbeat LED blinks green once every 3 seconds if one I/O module is
installed, or twice every 3 seconds if two I/O modules are installed.
•
•
Power and FRU LEDs display green continuously.
I/O module LEDs flash green if there is activity on that connection.
There are two LEDs on each Drive Carrier. They report the presence of power
and a disk drive, and the current condition of the drive.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2: Installation
Disk Status
Figure 21.VTrak J610s/J310s disk carrier LEDs
Power/Activity
Within one minute, the Power/Activity should display Green.
If there is no disk drive in the carrier, the Disk Status LED and the Power/Activity
LED will remain dark.
Setting Up the CLI Connection
The J610s or J310s unit has a Command Line Interface (CLI) to manage all of its
functions, including customization. Access the CLI via your PC’s terminal VT100
or ANSI emulation program, such as Microsoft HyperTerminal.
With the J610s or J310s unit running and the RJ11-to-DB9 serial data cable with
a null-modem cable connected to the primary I/O module:
1. Change your terminal emulation program settings to agree with the
following:
•
•
•
•
•
Bits per second: 115200
Data bits: 8
Parity: None
Stop bits: 1
Flow control: none
2. Start your PC’s terminal emulation program.
3. Press Enter once to launch the CLI.
The cli> prompt on your screen indicates that you have a connection and the
CLI is ready to accept commands.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Management
•
•
•
•
Front Status Indicators (below)
Drive Status Indicators (page 24)
I/O Module Status Indicators (page 25)
CLI Command Set (page 26)
Front Status Indicators
Even though the Command Line Interface (CLI) offers comprehensive monitoring
of VTrak, the LED indicators on the VTrak J610s or J310s unit provide important
status information.
When the power is switched on, the LEDs on the front of the VTrak will light up.
Figure 1. VTrak J310s front panel LED display. The J610s is similar
Power
FRU Status
Not Used
I/O module-1 activity
I/O module-2 activity
Heartbeat
When boot-up is finished and the VTrak is functioning normally:
•
The heartbeat LED blinks green once every 3 seconds if one I/O module is
installed, or twice every 3 seconds if two I/O modules are installed.
•
•
Power and FRU LEDs display green continuously.
I/O module LEDs flash green if there is activity on that connection.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
State
LEDs
Steady
Green
Flashing
Green
Dark
Amber
Red
Power
FRU*
System Off Normal
System Off Normal
1 CU and/or 2 CU and/or
1 PSU failed 2 PSU failed
I/O Module
1 or 2
No Activity
Activity
Heartbeat System Off
Normal**
* Field Replacement Unit: Cooling Unit (CU) or Power Supply Unit (PSU)
** Blinks intermittently.
Drive Status Indicators
After a few moments the Power/Activity should display Green.
If there is no disk drive in the carrier, the Disk Status LED and the Power/Activity
LED will remain dark.
Figure 2. VTrak J610s/J310s disk carrier LEDs
Disk Status
Power/Activity
The VTrak spins up the disk drives sequentially in order to equalize power draw
during start-up. After a few moments the Power/Activity and Disk Status LEDs
should display green.
the Power/Activity LED behavior depends on the specific disk drive.
The Disk Status LED behavior depends on your HBA or RAID controller. See the
table below.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Management
State
Steady Green Flashing Green
Drive Present Activity
HBA/RAID controller determines the LED behavior
LEDs
Dark
No Drive
Power/Activity*
Status**
* Refers to SAS drives or SATA drives with an AAMUX adapter.
For SATA drives without an AAMUX adapter, LED behavior depends on
the specific disk drive.
** Refer to the user documentation for your HBA or RAID controller for this
information.
I/O Module Status Indicators
The VTrak J610s or J310s I/O module has LEDs that indicate activity on each of
its ports.
Figure 3. VTrak J610s and J310s I/O Module LEDs
115200
8 N 1
Table Connector (CN2) LED
Subtractive Connector (CN1) LED
I/O Module Status LED
The I/O module status LED shows red at startup. Within 2 or 3 seconds, it turns
green to indicate that the I/O module is ready.
State
LEDs
Steady
Green
Flashing
Green
Dark
Link Down
Off
Red
Connectors
Link Up
Activity
I/O Module
Status
Ready
Starting up*
* Turns green 2 to 3 seconds after subsystem startup.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
Figure 4. VTrak J610s power supply and fan LEDs
Power Supply LED
Fan LED
The battery LED on the cooling unit has no function on the VTrak J610s and
J310s models.
Figure 5. VTrak J310s power supply and fan LEDs
Power Supply LED
Fan LED
O
I
Under normal conditions, the power supply and fan LEDs should display green.
State
LEDs
Dark
Green
OK
Red
Power supply
Fan
Not detected
Not detected
Failed
Failed
OK
To check a component’s installation, follow the same procedure as replacing the
component, except that you reinstall the original component rather than a new
one. In most cases, this action fixes a bad connection and allows VTrak to detect
the component. If this action does not correct the problem, replace the unit.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Management
CLI Command Set
The CLI has the following set of commands:
cable – Specifies the length of cable for optimal signal quality.
enclosure – Displays full information on the J610s or J310s enclosure and all its
components, expander addresses and SAS addresses.
help – Use alone or with a command, such as help enclosure, enclosure -help
or enclosure -h.
link – Displays the current status of the Phys (links) and the error counter.
route – Displays addresses of components through a downstream (expansion)
connection.
uptime – Displays the number of days, hours, minutes and seconds since the
firmware was loaded (the VTrak was started or restarted).
vpdr – Displays vital product data on field replaceable units.
? – Use alone or with a command, such as ? enclosure or enclosure -?
Note
Commands are case-sensitive. Disable the Caps Lock on your
keyboard.
Cable Command
The Cable command displays the current cable length settings for the two Host
ports and the Expansion port. The I/O module supports cables from 1 to 5 meters
in length.
To view current settings, at the cli> prompt, type cable and press Enter.
cli>cable
CN#1 Cable Length = 1 meter
CN#2 Cable Length = 1 meter
CN#1 and CN#2 are the external SAS connectors on the I/O module. See
To change the settings, enter the cable mod command, the connector number
and cable length. You can specify a cable length from 1 to 8 meters.
For example, to set the Expansion connector for a 3-meter cable, at the cli>
prompt, type cable -a mod -s “cn2=3” and press Enter.
To verify the setting change, at the cli> prompt, type cable and press Enter.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
cli>cable
CN#1 Cable Length = 1 meter
CN#2 Cable Length = 3 meter
Note the cable length change for CN2.
Enclosure Command
The Enclosure command:
•
•
Displays information about the J610s or J310s enclosure (below)
Enables you to make enclosure settings (page 36)
Information
The Enclosure command displays information about the J610s or J310s
enclosure, including:
•
•
•
•
Time since power-up
Enclosure type
•
•
•
•
•
Temperature sensor readings
Temperature threshold settings
Voltage sensor readings
I/O module information
PSU (power supply) status and
fan speeds
Expander SAS addresses
Attached SAS addresses
•
Blower status and fan speeds
The CLI reports information for the I/O module to which it is connected and for
the rest of the components in the J310s enclosure.
Under SAS specifications, both I/O modules are active at the same time. For
management purposes, the default primary I/O module role is Primary. If a
second I/O module is present, its role is Secondary. See the arrow below for I/O
Module Role in the display. Also see “Setting Up Data Cable Connections” on
In a J610s or J310s unit with two I/O modules, if the primary I/O module fails or is
removed, the remaining I/O module becomes the default primary I/O module and
assumes the Primary role. If the other I/O module is repaired or replaced, it
becomes the secondary I/O module and assumes the Secondary role.
At the cli> prompt, type enclosure and press Enter.
cli> enclosure
-------------------------------------------------------------------------------------
Time Since Power Up: 1 hour 46 minutes 36 seconds
Enclosure: J310s-12Bay
34
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Management
I/O Module ID: 1
Max Num Of I/O Modules: 2
FwVersion: 1.00.0000.00
MaxNumOfHDSlots: 12
MaxNumOfFans: 4
I/O Module Role: Primary
MaxNumOfPSUs: 2
MaxNumOfBlowers: 2
MaxNumOfTempSensors: 8
MaxNumOfVoltageSensors: 5
===========================================
PSU Status Fan1Speed Fan2Speed
===========================================
1
2
Operational
Operational
14735 rpm
15340 rpm
15037 rpm
14361 rpm
===========================================
Blower Status Speed
===========================================
1
Operational
4017 rpm
2
Operational
4066 rpm
===========================================
ID Location Temp Reading ID Location Temp Reading
===========================================
1. Backplane
3. Backplane
32C/89F 2. Backplane
31C/87F 4. Backplane
32C/89F
30C/86F
5. I/O Module1 40C/104F 6. I/O Module1 30C/86F
7. I/O Module2 36C/96F 8. I/O Module2 28C/82F
Thermal Management: Enabled
Allows to shut down the system when critical temperature is reached: Yes
Current minimum fan speed setting: medium low
Enclosure Temp Threshold: 61C/141F (critical) 51C/123F (warning)
Controller Temp Threshold: 71C/159F (critical) 61C/141F (warning)
===========================================
VoltageSensor Voltage
===========================================
1
2
3
4
5
3.3V
5.2V
5.2V
12.5V
1.2V
Expander SAS Address:
SAS Base Addr:50 00 15 5D 21 AB 02 00
SSP SAS Addr: 50 00 15 5D 21 AB 02 3E
SMP SAS Addr: 50 00 15 5D 21 AB 02 3F
Attached SAS Address:
35
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
D01 SAS Addr: 50 00 15 E0 11 4E 5E B2
D02 SAS Addr: 50 00 15 E0 11 4E 80 C2
D03 SAS Addr: 50 00 15 E0 11 4C 22 02
D04 SAS Addr: 50 00 15 E0 11 4D E2 22
D05 SAS Addr: 50 00 15 E0 11 4D 8F B2
D06 SAS Addr: 50 00 15 E0 11 4D D0 62
D07 SAS Addr: 50 00 15 E0 11 4D DE E2
D08 SAS Addr: 50 00 15 E0 11 4D 8E F2
D09 SAS Addr: 50 00 15 E0 11 4C 97 62
D10 SAS Addr: 50 00 15 E0 11 4C 36 62
D11 SAS Addr: No Device Attached
D12 SAS Addr: No Device Attached
CN1 SAS Addr: 50 06 05 B0 00 01 69 64
CN2 SAS Addr: No Device Attached
CN3 SAS Addr: 50 00 15 5D 21 AA 12 3F
Settings
The Enclosure command enables you to make settings for the enclosure. The
J310s is shown. The J610s is similar.
•
•
•
•
•
•
•
Enclosure Critical Temperature – 51°C (123°F) to 61°C (141°F), measured
at the backplane
Enclosure Warning Temperature – 10°C (50°F) to 51°C (123°F), measured
at the backplane
Controller Critical Temperature – 61°C (141°F) to 71°C (160°F), measured
inside the I/O module
Controller Warning Temperature – 10°C (50°F) to 61°C (141°F), measured
inside the I/O module
Thermal Management – Monitors enclosure temperature, adjusts fan
speeds, displays red LED on cooling unit when a fan fails
Automatic Shutdown – Shuts down the J310s when it reaches the enclosure
or controller critical temperature
Minimum Fan Speed – Specifies the minimum fan speed when the J310s
reaches enclosure or controller warning temperature
To set the enclosure critical temperature to 61°C (141°F), at the cli> prompt, type
enclosure -a mod -s “enc_critical=61” and press Enter.
To enable Thermal Management, at the cli> prompt, type enclosure -a mod -s
“thermalmanager=1” and press Enter.
For this command, a 1 enables and a 0 disables.
To enable Automatic Shutdown, at the cli> prompt, type enclosure -a mod -s
“allowshutdown=1” and press Enter.
36
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Management
For this command, a 1 enables and a 0 disables.
To set the minimum fan speed to medium high, at the cli> prompt, type
enclosure -a mod -s “minfanspeed=3” and press Enter.
For this command, 1 means low, 2 means medium-low, 3 means medium-high,
and 4 means high. The actual speed depends on the fan manufacturer.
For a complete list of Enclosure commands, at the cli> prompt, type enclosure
-h and press Enter.
Help Command
The J610s and J310s CLI uses the standard Unix online help system.
For general help, at the cli> prompt, type help and press Enter.
For help with a specific function, type the name of the function and help or -h. For
example:
•
•
•
At the cli> prompt, type cable -h and press Enter.
At the cli> prompt, type cable -help and press Enter.
At the cli> prompt, type help cable and press Enter.
Link Command
The Link command displays information about the J310s links, including:
•
•
Link Status
Link Counter
At the cli> prompt, type link and press Enter.
Link Status:
Port
D01
D02
D03
D04
D05
D06
D07
D08
D09
D10
D11
D12
CN1
Type
SAS
SAS
SAS
SAS
SAS
SAS
SAS
SAS
SAS
SAS
----
Rate
3.0G
3.0G
3.0G
3.0G
3.0G
3.0G
3.0G
3.0G
3.0G
3.0G
----
Init
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
----
----
OK
Dev
End
End
End
End
End
End
End
End
End
End
----
Link
----
----
----
----
----
----
----
----
----
----
----
----
----
PRdy
Rdy
Rdy
Rdy
Rdy
Rdy
Rdy
Rdy
Rdy
Rdy
Rdy
----
P 0
P 1
P 2
P 3
P 4
P 5
P 6
P 7
P 8
P 9
P10
P11
P12
----
SAS
----
3.0G
----
End
----
Rdy
37
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
P13
P14
P15
P16
P17
P18
P19
CN1
CN1
CN1
CN2
CN2
CN2
CN2
SAS
SAS
SAS
----
----
----
----
3.0G
3.0G
3.0G
----
----
----
OK
OK
OK
----
----
----
----
End
End
End
----
----
----
----
----
----
----
----
----
----
----
Rdy
Rdy
Rdy
----
----
----
----
----
Port:Port Id
Type:SAS
Rate:Rate 3G
Init:Init Passed Dev:Device Type Link:Link Connected
PRdy:Phy Ready
The following items are reported in the table above:
•
•
Link number – The links are Phys, numbered P0 through P23
Port number – Each disk-drive slot has a Phy. Each connector has 4 Phys.
D01 though D12 are disk-drive slot numbers. See “Drive Numbering” on
CN1 and CN2 are the external SAS connectors on the I/O module. See
•
•
•
•
Drive Type – SAS
Data Rate – 3.0 Gb/s
Device Type – End means an end device, Exp means an expansion device
Link Connection – Normally, ---- is displayed. If there is a connection at the
moment the link command runs, it will display CONN
•
Phy Ready Status – If the port is ready, it will display Rdy
Link Counter:
InDW
DsEr
DwLo
PhRe
CoVi
PRBS
PhCh
P 0 ---------- ---------- ---------- ---------- ---------- ---------- 0x01
P 1 ---------- ---------- ---------- ---------- ---------- ---------- 0x01
P 2 ---------- ---------- ---------- ---------- ---------- ---------- 0x01
P 3 ---------- ---------- ---------- ---------- ---------- ---------- 0x01
P 4 ---------- ---------- ---------- ---------- ---------- ---------- 0x01
P 5 ---------- ---------- ---------- ---------- ---------- ---------- 0x0B
P 6 ---------- ---------- ---------- ---------- ---------- ---------- 0x01
P 7 ---------- ---------- ---------- ---------- ---------- ---------- 0x01
P 8 ---------- ---------- ---------- ---------- ---------- ---------- 0x01
P 9 ---------- ---------- ---------- ---------- ---------- ---------- 0x01
P10 ---------- ---------- ---------- ---------- ---------- ---------- ----------
P11 ---------- ---------- ---------- ---------- ---------- ---------- ----------
P12 ---------- ---------- ---------- ---------- ---------- ---------- 0x01
P13 0x0F
0x0E
0x01
---------- 0x06
0x0C
0x02
P14 ---------- ---------- ---------- ---------- ---------- ---------- 0x01
38
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Management
P15 ---------- ---------- ---------- ---------- ---------- ---------- 0x01
P16 ---------- ---------- ---------- ---------- ---------- ---------- ----------
P17 ---------- ---------- ---------- ---------- ---------- ---------- ----------
P18 ---------- ---------- ---------- ---------- ---------- ---------- ----------
P19 ---------- ---------- ---------- ---------- ---------- ---------- ----------
InDW:Invalid Dword Count DsEr:Disparity Err Count
DwLo:Dword Sync Loss Count
PhRe:Phy Reset Problem Count CoVi:Code Violations Cnt
PRBS:PRBS Error Count
PhCh:Phy Change Count
The following items are reported in the table above. All counts are hexadecimal:
•
•
•
•
•
•
•
Link number – Links are Phys, numbered P0 through P23
Invalid D-word Count
Disparity Error Count
Phy Reset Problem Count
Code Violation Count
Pseudo-Random Bit-Stream Error Count
Phy Change Count
If the count is zero, the counter shows dashes (----------). The fact that errors
occur does not necessarily indicate a problem or that the J610s or J310s unit is
malfunctioning.
An individual error count incrementing at intervals of less than six minutes
indicates a possible problem and requires further investigation.
To clear the link error count, at the cli> prompt, type link -a clear and press
Enter.
Route Command
Use this command to show the SAS addresses of the devices in your domain.
At the cli> prompt, type route and press Enter.
Routing Table Mapping:
Entry# SAS Address
PortID CnID NextEntry NextValid
-------------------------------------------------------------------------------------
0083 500000E01122C533 0x10
0121 500000E01122C4A3 0x10
0226 500000E01122C513 0x10
0244 500000E011246263 0x10
0358 500000E011231F43 0x10
0466 500000E0112770B3 0x10
CN1
CN1
CN1
CN1
CN1
CN1
----
----
----
----
----
----
0
0
0
0
0
0
39
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
0488 500000E01122C0F3 0x10
CN1
CN1
CN1
CN1
CN1
CN1
CN1
----
----
----
----
----
----
----
0
0
0
0
0
0
0
0519 500000E01122C493 0x10
0731 500000E01122C5B3 0x10
0751 500000E01122C5C3 0x10
0851 500000E01122C583 0x10
0864 5000155D21AB433E 0x10
0945 500000E0112313C3 0x10
The route command displays SAS addresses that are attached to one of the
external ports on the J610s or J310s unit. Six items are reported:
•
•
•
•
•
•
Entry Number – Arbitrary numbers, listed in sequence
SAS Address – Of the disk drive or other component
Port ID – Phy numbers, shown in hexadecimal
Connector ID – One of two external SAS ports on the J610s or J310s unit
Next Entry – The next entry number for the same SAS address
Next Valid – 1 means there is another one. 0 means this is the last one
This device is connected to the J610s or J310s unit through connector CN1. See
page 21 for a diagram of connectors on the I/O module.
If you type route at the cli> prompt and press Enter, then see the following
message:
No SAS Routing Entry Exists
...it indicates that no devices are found on the table-routed (CN2) connector.
Uptime Command
The uptime command informs you of the elapsed period of time since the J610s
or J310s unit was powered on.
To display uptime, at the cli> prompt, type uptime and press Enter.
cli>uptime
System has been running 1 hour 46 minutes 35 seconds
40
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Management
VPDR Command
The vpdr command displays vital product data on the major components of the
J610s or J310s unit. There are six components that report vital product
information.
•
•
•
•
•
•
1 – Controller (I/O module)
2 – Power Supply 1
3 – Cooling Unit 1
4 – Power Supply 2
5 – Cooling Unit 2
6 – Backplane
Specify the component by its number. For example, to display vital product data
for the controller (I/O module), at the at the cli> prompt, type vpdr -i 1 and press
Enter.
cli>vpdr -i 1
Board ID
: 1
OEM Name : IOC
OEM Model : J310s
Mfg Part
Mfg SN
Mfg Rev
Mfg Date
WWN
: IOC-J310s-01
: S0026
: A2R4
: 2005:08:18
: 20 00 00 01 55 D2 1A A1
? Command
The VTrak CLI uses the standard Unix online help system.
For the command usage of a particular function, type the name of the function
followed by ?. For example, at the cli> prompt, type cable -? and press Enter.
For help with a particular function, type ? followed by the name. For example, at
the cli> prompt, type ? cable and press Enter.
The result of typing ? followed by the name is the same as typing help followed
by the name.
41
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
42
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4: Support
•
•
•
•
Frequently Asked Questions (below)
Returning product for repair (page 48)
Frequently Asked Questions
What kind of disk drives can I use with J610s and J310s?
The J610s and J310s support 3.5-inch Serial Attached SCSI (SAS) disk
drives and SATA II disk drives. If you use SATA disk drives, on a VTrak with
two I/O modules, you must also install an AAMUX adapter for each SATA
drive.
How can I tell when the J610s or J310s unit has fully booted?
When the J610s or J310s unit is fully booted up, the Power and FRU LEDs
will light up green. The heartbeat LED blinks green once every 3 seconds if
one I/O module is installed, or twice every 3 seconds if two I/O modules are
installed.
How can I tell my CLI connection is to the primary default I/O module?
After you establish the CLI connection, type Enclosure and press Enter.
Look at the top of the display for an item called I/O Module Role. If the Role
is Primary, you are connected to the default primary I/O module. If the Role
is Secondary, you are connected to the default secondary.
What happens if a disk drive fails?
Depending on the nature of the failure, the failed drive the drive might not
appear in the CLI, or the failed drive might appear with an error, when you
page 37).
Can I hot-swap a failed drive with a new one?
Yes. Disk drives are hot-swappable on the J610s and J310s units.
Can the J610s and J310s run using just one power supply?
Yes, it is possible to run J610s and J310s unit on a single power supply.
J610s and J310s units ship with two power supplies. The J610s or J310s
unit will continue running if one of the power supply fails. But deliberately
leaving one power supply off negates this advantage.
43
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
In addition, leaving one power supply off reduces air flow through the J610s
or J310s enclosure and can contribute to overheating. Always switch on both
power supplies if your J610s or J310s unit has two.
Contacting Technical Support
Promise Technical Support provides several support options for Promise users to
access information and updates. We encourage you to use one of our electronic
services, which provide product information updates for the most efficient service
and support.
Important
Promise offers 24x7 live technical support (in English only) for
registered owners of VTrak products. To register, point your
browser to:
If you decide to contact us, please have the following information available:
•
•
•
•
Product model and serial number
BIOS, firmware and driver version numbers
A description of the problem / situation
System configuration information, including: motherboard and CPU type,
hard drive model(s), SAS/SATA/ATA/ATAPI drives & devices, and other
controllers.
Technical Support Services
Promise Online™ Web Site
(technical documents, drivers, utilities, etc.)
(online request form)
Promise Online™ eSupport
44
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4: Support
United States
E-mail Support
Fax Support
(408) 228-1097 Attn: Technical Support
(408) 228-1400 option 4
Phone Support
If you wish to write us for
support:
Promise Technology, Inc.
580 Cottonwood Drive
Milpitas, CA 95035, USA
The Netherlands
E-mail Support
Fax Support
+31 (0) 40 256 9463 Attn: Technical Support
+31 (0) 40 235 2600
Phone Support
If you wish to write us for
support:
Promise Technology Europe B.V.
Science Park Eindhoven 5542
5692 EL Son, The Netherlands
Germany
E-mail Support
Fax Technical Support
+49 (0) 2 31 56 76 48 - 29
Attn: Technical Support
Phone Technical Support
+49 (0) 2 31 56 76 48 - 10
If you wish to write us for
support:
Promise Technology Germany
Europaplatz 9
44269 Dortmund, Germany
Italy
E-mail Support
Fax Support
0039 06 367 12400 Attn: Technical Support
0039 06 367 12626
Phone Support
If you wish to write us for
support:
Promise Technology Italy
Piazza del Popolo 18
00187 Roma, Italia
45
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
Taiwan
E-mail Support
Fax Support
+886 3 578 2390 Attn: Technical Support
+886 3 578 2395 (ext. 8811)
Phone Support
If you wish to write us for
support:
Promise Technology, Inc.
2F, No. 30, Industry E. Rd. IX
Science-based Industrial Park
Hsin-Chu 30075, Taiwan, (R.O.C.)
China
E-mail Support
Fax Support
+86-10-8857-8015 Attn: Technical Support
+86-10-8857-8085/8095
Phone Support
If you wish to write us for
support:
Promise Technology China
Room 1205, Tower C
Webok Time Center, No.17
South Zhong Guan Cun Street
Hai Dian District, Beijing 100081, China
46
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4: Support
Limited Warranty
Promise Technology, Inc. (“Promise”) warrants that for three (3) years from the
time of the delivery of the product to the original end user:
a) the product will conform to Promise’s specifications;
b) the product will be free from defects in material and workmanship under
normal use and service.
This warranty:
a) applies only to products which are new and in cartons on the date of
purchase;
b) is not transferable;
c) is valid only when accompanied by a copy of the original purchase
invoice.
d) Is not valid on spare parts, fans, and power supplies
This warranty shall not apply to defects resulting from:
a) improper or inadequate maintenance, or unauthorized modification(s),
performed by the end user;
b) operation outside the environmental specifications for the product;
c) accident, misuse, negligence, misapplication, abuse, natural or
personal disaster, or maintenance by anyone other than a Promise or a
Promise-authorized service center.
Disclaimer of other warranties
This warranty covers only parts and labor, and excludes coverage on software
items as expressly set above.
Except as expressly set forth above, Promise DISCLAIMS any warranties,
expressed or implied, by statute or otherwise, regarding the product, including,
without limitation, any warranties for fitness for any purpose, quality,
merchantability, non-infringement, or otherwise. Promise makes no warranty or
representation concerning the suitability of any product for use with any other
item. You assume full responsibility for selecting products and for ensuring that
the products selected are compatible and appropriate for use with other goods
with which they will be used.
Promise DOES NOT WARRANT that any product is free from errors or that it will
interface without problems with your computer system. It is your responsibility to
back up or otherwise save important data before installing any product and
continue to back up your important data regularly.
47
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
No other document, statement or representation may be relied on to vary the
terms of this limited warranty.
Promise’s sole responsibility with respect to any product is to do one of the
following:
a) replace the product with a conforming unit of the same or superior
product;
b) repair the product.
Promise shall not be liable for the cost of procuring substitute goods, services,
lost profits, unrealized savings, equipment damage, costs of recovering,
reprogramming, or reproducing of programs or data stored in or used with the
products, or for any other general, special, consequential, indirect, incidental, or
punitive damages, whether in contract, tort, or otherwise, notwithstanding the
failure of the essential purpose of the foregoing remedy and regardless of
whether Promise has been advised of the possibility of such damages. Promise
is not an insurer. If you desire insurance against such damage, you must obtain
insurance from another party.
Some states do not allow the exclusion or limitation of incidental or consequential
damages for consumer products, so the above limitation may not apply to you.
This warranty gives specific legal rights, and you may also have other rights that
vary from state to state. This limited warranty is governed by the State of
California.
Your Responsibilities
You are responsible for determining whether the product is appropriate for your
use and will interface with your equipment without malfunction or damage. You
are also responsible for backing up your data before installing any product and
for regularly backing up your data after installing the product. Promise is not
liable for any damage to equipment or data loss resulting from the use of any
product.
Returning Product For Repair
If you suspect a product is not working properly, or if you have any questions
about your product, contact our Technical Support Staff through one of our
Technical Services, making sure to provide the following information:
•
•
•
•
•
Product model and serial number (required)
Return shipping address
Daytime phone number
Description of the problem
Copy of the original purchase invoice
48
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4: Support
The technician will assist you in determining whether the product requires repair.
If the product needs repair, the Technical Support Department will issue an RMA
(Return Merchandise Authorization) number.
Important
Obtain an RMA number from Technical Support before you return
the product and write the RMA number on the label. The RMA
number is essential for tracking your product and providing the
proper service.
Return ONLY the specific product covered by the warranty (do not ship cables,
manuals, diskettes, etc.), with a copy of your proof of purchase to:
USA and Canada:
Other Countries:
Promise Technology, Inc.
Customer Service Dept.
Attn.: RMA # ______
47654 Kato Road
Fremont, CA 94538
Return the product to your dealer
or retailer.
Contact them for instructions
before shipping the product.
You must follow the packaging guidelines for returning products:
•
•
•
•
Use the original shipping carton and packaging
Include a summary of the product’s problem(s)
Write an attention line on the box with the RMA number
Include a copy of proof of purchase
You are responsible for the cost of insurance and shipment of the product to
Promise. Note that damage incurred due to improper transport or packaging is
not covered under the Limited Warranty.
When repairing returned product(s), Promise may replace defective parts with
new or reconditioned parts, or replace the entire unit with a new or reconditioned
unit. In the event of a replacement, the replacement unit will be under warranty
for the remainder of the original warranty term from purchase date, or 30 days,
whichever is longer.
Promise will pay for standard return shipping charges only. You will be required
to pay for any additional shipping options (such as express shipping).
49
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
50
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Second I/O Module
The VTrak J610s and J310s units ship with one or two I/O modules. If your J610s
or J310s came with only one I/O module, you can upgrade by installing a second
I/O module. The following instructions describe how to install a second I/O
module.
To install a second I/O module in a VTrak J610s or J310s unit:
1. Power down the J610s or J310s unit.
2. Press the release button on the dummy I/O module, pull the handle down
and remove the dummy I/O module from the enclosure.
3. Slide the new I/O module into the slot.
4. Gently push the new I/O module all the way into the slot until the handle
locks.
5. Connect your data cables to the new I/O module.
6. Optional. Connect your serial cable to the second I/O module.
7. Power up the J610s or J310s unit.
To verify proper installation and function, run the enclosure command in the CLI.
Because the new I/O module is installed in the right slot, it will automatically take
51
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
52
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
Symbols
? command 41
D
DAS
basic 22
cascade 23
redundant 24
A
About This Manual 1
Attached SAS addresses 34
automatic shutdown setting 36
supported 20
Data cable connections 20
Basic DAS 22
Cascading DAS 23
Redundant DAS 24
Dimensions 7
B
blower status 34
disk drives
drive carriers 18
hot-swappable 43
install 16
C
cable
command 33
null modem 25, 27
RJ11-to-DB9 25, 27
CE statement 7
Certifications 7
CN1, CN2 21, 22, 25
Command
numbering 19
E
enclosure command 34, 43
end device 22
Environmental 6
error counts 39
? 41
cable 33
ESD Warning 9
expander SAS addresses 34
CLI 33
enclosure 34, 43
help 37
F
link 37, 43
route 39
FCC statement 7
Features and Benefits 5
Frequently Asked Questions 43
FRU LED 26, 29
set 33
uptime 40
vpdr 41
component data 41
Connection
CLI 27
H
Heartbeat LED 26, 29
help command 37
data cables 20
power 26
serial 25
cooling unit LED 32
53
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
I
P
I/O module 10, 26
add second module 51
default primary 20
dual 25
Phy ready status 38
port
number 38
SAS ports 22, 23
Power
L
LEDs
connection 26
LED 26, 29
cooling unit 32
disk drives 30
drive carrier 26
fan 32
front 29
front panel 26, 29
FRU 29
requirements 6
power supply 10
LED 32
single 43
status 34
primary I/O module 20
heartbeat 29
I/O module 31
power 29
R
rackmount
power supply 32
link
E310f/s 13
E610f/s 11
connection 38
number 38
status and counter 37
regulatory statements 7
RJ11-to-DB9
cable 9, 25, 27
connector 25
RMA number 49
route command 39
routing table mapping 39
RS232 serial communication 25
M
mapping, routing table 39
minimum fan speed setting 36
N
S
SAS
null-modem cable 25, 27
address 39
O
cable 9, 22, 23, 25
end device 22
expander address 34
screws, counter-sink 16
Operating Systems, supported 6
54
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
Serial cable connections 25, 27
setting
U
Unpack the VTrak 9
automatic shutdown 36
minimum fan speed 36
temperature 36
uptime command 40
V
thermal management 36
Specifications 6
vital product data 41
voltage sensors 34
vpdr command 41
VTrak
Status Indicators
disk drives 30
front 29
rackmount E310f/s 13
rackmount E610f/s 11
returning for repair 48
unpack 9
I/O module 31
status, phy 38
warranty 7
T
W
table-routed port 21, 23, 25
Technical Support 44
temperature
Warranty 47
sensors 34
settings 36
thermal management setting 36
55
Download from Www.Somanuals.com. All Manuals Search And Download.
VTrak J610s, J310s Product Manual
56
Download from Www.Somanuals.com. All Manuals Search And Download.
|