Promise Technology Computer Accessories J310s User Manual

VTRAK  
J610S, J310S  
PRODUCT MANUAL  
Version 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1: Introduction  
About This Manual (below)  
Thank you for purchasing Promise Technology’s VTrak J610s or J310s external  
disk array subsystem.  
About This Manual  
This Product Manual describes how to setup, use and maintain the VTrak J610s  
or J310s external disk subsystem. It also describes how to use the built-in  
command-line interface (CLI) software.  
This manual includes a full table of contents, index, chapter task lists and  
numerous cross-references to help you find the specific information you are  
looking for.  
Also included are four levels of notices:  
Note  
A Note provides helpful information such as hints or alternative  
ways of doing a task.  
Important  
An Important calls attention to an essential step or point required  
to complete a task. Important items include things often missed.  
Caution  
A Caution informs you of possible equipment damage or loss of  
data and how to avoid them.  
Warning  
A Warning notifies you of probable equipment damage or loss of  
data, or the possibility of physical injury, and how to avoid them.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
VTrak J610s, J310s Product Manual  
Overview  
The Promise VTrak J610s and J310s are optimized for organizations deploying  
cost-effective small-to-medium application clusters, disk-to-disk backup and  
midrange storage solutions.  
Figure 1. VTrak J610s front view with bezel removed  
Drive Carrier LEDs  
Drive Carriers  
Power and Status LEDs  
Figure 2. VTrak J310s front view with bezel removed  
Drive Carrier LEDs  
Drive Carriers  
Power and Status LEDs  
The dual 3Gb SAS host interface ports offer the ease of management and  
performance required by companies running popular departmental and back-  
office applications including file/print, e-mail, database and Web services  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 1: Introduction  
Figure 3. VTrak J610s rear view  
I/O module 1  
I/O module 2  
115200  
115200  
8
N
1
8
N
1
Power Supply 2  
Power Supply 2  
Power Supply 1 Cooling Unit 1 Cooling Unit 2  
Figure 4. VTrak J310s rear view  
Power Supply 1 Cooling Unit 1 Cooling Unit 2  
O
I
O
I
115200  
115200  
8
N
1
8
N
1
I/O module 1  
I/O module 2  
The two external SAS ports provide the needed connectivity and bandwidth for  
large capacity solutions requiring multiple JBOD boxes cascaded together while  
still providing dual server support and host port failover or aggregation.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
VTrak J610s, J310s Product Manual  
Architectural Description  
The VTrak J610s packs up to 16 drives per system, offering industry-leading  
capacity in just 3U of standard 19-inch rack space. The VTrak J310s supports up  
to 12 drives per system, in just 2U of standard 19-inch rack space. The J610s  
and J310s unit’s compact form factor maximizes density, increasing capacity per  
unit of rack space.  
Multiple J610s and J310s systems can also be connected to the same server  
using standard SAS features to deliver massive storage to capacity hungry  
applications such as disk-to-disk backup, media archiving, video surveillance and  
compliance storage  
Promise has designed the J610s and J310s chassis to be fully compatible with all  
future Promise external storage products. By using the same chassis, drive  
carriers, and cooling units, upgrading the RAID controllers and JBOD modules is  
fast and simple.  
With the VTrak J610s and J310s, Promise has dramatically narrowed the gap  
between simple fault tolerance and No Single Point of Failure. The VTrak J610s  
and J310s use a fully redundant, hot-swap design and continuously monitors all  
system components. It can withstand failures to disks, power supplies, cooling  
and I/O modules without interrupting system operation.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 1: Introduction  
Features and Benefits  
Feature  
Benefit  
3U or 2U 19-inch wide enclosure  
Installs easily in any standard rackmount.  
Supports Serial Attached SCSI  
disk drives  
Allows you to use the new dual-port SAS  
disk drives.  
Supports Serial ATA disk drives  
Allows you to use your legacy SATA disk  
drives.  
Hot-swap feature for drive carriers, Allows a defective component to be  
I/O modules, power supplies and replaced without interrupting data  
fans  
accessibility to the host system.  
Tool-less field-replaceable units  
(FRUs)  
All FRUs can be replaced without tools,  
saving time and effort for support personnel.  
Complete cable-less design  
All components easily plug directly into  
boards. No cables to complicate setup or  
maintenance.  
Redundant, hot-swappable cooling Load sharing and full operation even with  
units multiple failed fans.  
Redundant, hot-swappable power Load sharing and full operation even with a  
supplies  
failed power supply.  
Dual, active/active I/O Modules  
High level of availability even with a failed  
I/O module.  
One host SAS port per I/O module Two I/O modules are needed to set up  
clustering.  
One expansion SAS port I/O  
module  
Enables cascading JBOD subsystems.  
Command-line interface  
Control and monitoring with simple,  
straightforward interface.  
Management through in-band SAS Choice of local or network management  
or serial port options  
Compatible with leading SAS HBA Easy, works-the-first-time connections with  
and RAID cards your current systems  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
VTrak J610s, J310s Product Manual  
Specifications  
Drive Capacity: J610s, 16 drives. J310s, 12 drives.  
External I/O Ports: SAS host port and SAS expansion port.  
Supported Disk Interfaces: Serial Attached SCSI (SAS) and Serial ATA (SATA),  
3Gb/s and 1.5Gb/s  
Supported Operating Systems:  
Windows Vista, Business,  
Enterprise, or Ultimate  
RedHat Linux  
SuSE Linux  
Windows 2003 Server  
Windows XP Professional  
Windows 2000  
Novell Netware  
Sun Solaris  
The list above refers to 32-bit and 64-bit versions of the OS in the Host PC or  
server. The actual OS support depends upon your SAS HBA or RAID  
adapter. Check your SAS HBA or RAID adapter user documentation.  
Voltage: 100–240 VAC Auto-ranging.  
Current: 8 A @ 100 VAC; 4 A @ 240 VAC Current rating with two power cords  
Power Consumption (not including disk drives):  
J610s, 108.38 W.  
J310s, 100.87 W.  
Power Consumption (including disk drives):  
J610s, 523.91 W.  
J310s, 412.51 W.  
Power Supply:  
J610s, Dual 500W, 100–240 VAC auto-ranging, 50–60 Hz, dual hot swap and  
redundant with PFC, N+1 design.  
J310s, Dual 400W, 100–240 VAC auto-ranging, 50–60 Hz, dual hot swap and  
redundant with PFC, N+1 design.  
Operating Temperature:  
5° to 40°C operational  
-40° to 60°C non-operational  
Relative Humidity: Maximum 95%  
Vibration: Random, 0.21 grms, 5 to 500 Hz, 30 Mins, X, Y, Z axis  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Chapter 1: Introduction  
Dimensions (H x W x D):  
J610s, 13.1 x 44.7 x 56.1 cm (5.2 x 17.6 x 22.1 in)  
J310s, 8.8 x 44.7 x 56.1 cm (3.5 x 17.6 x 22.1 in)  
Net Weight:  
J610s, 30.5 kg (67.2 lb) without drives, 38.5 kg (84.9 lb) with 16 drives, assuming  
0.5 kg (1.1 lb) per drive.  
J310s, 26.5 kg (58.4 lb) without drives, 32.5 kg (71.7 lb) with 12 drives, assuming  
0.5 kg (1.1 lb) per drive.  
Gross Weight (including carton):  
J610s, 37.5 kg (82.7 lb) without drives.  
J310s, 33.0 kg (72.8 lb) without drives.  
Safety: CE, FCC Class A, VCCI, C-Tick, cUL, TUV, CB, BSMI, MIC.  
Warranty and Support  
Warranty: Three years complete system limited warranty.  
Support: 24x7 email and phone support (English only). 24x7 access to Promise  
support site for drivers, firmware, and compatibility.  
FCC Statement  
This device complies with Part 15 of the FCC Rules. Operation is subject to the  
following two conditions: (1) this device may not cause harmful interference, and  
(2) this device must accept any interference received, including interference that  
may cause undesired operation.  
CE Statement  
Warning: This is a class A product. In a domestic environment this product may  
cause radio interference in which case the user may be required to take  
adequate measures.  
MIC Statement  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
                 
VTrak J610s, J310s Product Manual  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
Unpacking the VTrak (below)  
Unpacking the VTrak  
The VTrak J610s or J310s box contains the following items:  
VTrak J610s or J310s Unit  
Quick Start Guide  
Screws for disk drives  
(J610s: 70, including 6 spares)  
(J310s: 50, including 2 spares)  
Front bezel and key  
Left and right mounting rails  
RJ11-to-DB9 serial data cable  
(Units with one I/O module: 1)  
(Units with two I/O modules: 2)  
Left and right center-mount brackets  
1.5m (4.9 ft) Power cords (2)  
1.0m (3.3 ft) SAS cable  
CD with Product Manual and Quick  
(Units with one I/O module: 1)  
(Units with two I/O modules: 2)  
Start Guide  
Warning  
The electronic components within the J610s and J310s units are  
sensitive to damage from Electro-Static Discharge (ESD).  
Observe appropriate precautions at all times when handling the  
J610s or J310s unit or its subassemblies.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
VTrak J610s, J310s Product Manual  
Figure 1. VTrak J610s rear view  
I/O module 1  
I/O module 2  
115200  
115200  
8
N
1
8
N
1
Power Supply 2  
Power Supply 2  
Power Supply 1 Cooling Unit 1 Cooling Unit 2  
Figure 2. VTrak J310s rear view  
Power Supply 1 Cooling Unit 1 Cooling Unit 2  
O
I
O
I
115200  
115200  
8
N
1
8
N
1
I/O module 1  
I/O module 2  
Some J610s and J310s units ship with a single I/O module and a blank unit  
installed in the place of the second I/O module. You can upgrade your J610s or  
J310s unit by installing a second I/O module. See page 51.  
Some J610s and J310s units ship with a single power supply and an auxiliary  
cooling unit installed in the place of the second power supply to provide a  
comparable level of air circulation inside the enclosure.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Chapter 2: Installation  
Mounting VTrak J610s in a Rack  
The J610s subsystem installs to the rack using the supplied mounting rails. You  
can also use your existing rails.  
Figure 3. VTrak J610s mounted in a rack with the supplied rails  
Vertical Rack Post  
VTrak J610s  
Mounting rails (included)  
mount outside the rack post  
Handles mount  
outside the rack post  
Cautions  
At least two persons are required to safely lift, place, and  
attach the VTrak subsystem into a rack system.  
Do not lift or move the VTrak subsystem by the handles,  
power supplies or the controller units. Hold the subsystem  
itself.  
Do not install the VTrak subsystem into a rack without rails to  
support the subsystem.  
Only a qualified electrician who is familiar with the installation  
procedure should mount and install the VTrak subsystem.  
Be sure all switches are OFF before installing the VTrak  
subsystem or exchanging components.  
To install the J610s subsystem into a rack with the supplied mounting rails:  
1. Check the fit of the mounting rails in your rack system. See Figure 4.  
2. Adjust the length of the mounting rails as needed.  
3. Attach the mounting rail assemblies to the outside of the rack posts, using  
the attaching screws from your rack system.  
Be sure the support is on the bottom facing inward.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
VTrak J610s, J310s Product Manual  
4. Square the rail assemblies in the rack.  
5. Tighten the adjustment screws and the attaching screws.  
6. Place the VTrak subsystem onto the rails.  
7. Secure the VTrak subsystem to the rack through each handle, using the  
attaching screws from your rack system.  
Figure 4. Rack mount assembly diagram  
Rack front post  
Rack back post  
Rail attaching screw  
(not included)  
Rail attaching screw  
(not included)  
Front rail  
Rear rail  
Flange  
Support  
Rail adjustment screw  
Rail adjustment screw  
Inside of post  
Inside of post  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
Mounting VTrak J310s in a Rack  
The J310s subsytem installs to the rack using the supplied mounting rails. You  
can also use your existing rails.  
Figure 5. VTrak J310s mounted in a rack with the supplied rails  
VTrak J310s  
Vertical Rack Post  
Handles mount  
outside the rack post  
Mounting rails (included)  
mount outside the rack post  
Cautions  
At least two persons are required to safely lift, place, and  
attach the VTrak subsystem into a rack system.  
Do not lift or move the VTrak subsystem by the handles,  
power supplies or the controller units. Hold the subsystem  
itself.  
Do not install the VTrak subsystem into a rack without rails to  
support the subsystem.  
Only a qualified electrician who is familiar with the installation  
procedure should mount and install the VTrak subsystem.  
Be sure all switches are OFF before installing the VTrak  
subsystem or exchanging components.  
To install the VTrak subsystem into a rack with the supplied mounting rails:  
1. Check the fit of the mounting rails in your rack system. See Figure 7.  
2. Slide the plates out of the mounting rails.  
3. Attach one plate to each side of the VTrak subsystem.  
Line-up the six holes in the plate with the corresponding holes in the  
subsystem. Attach each plate with six screws (included). See Figure 6.  
4. Slide one of the rails over the plate on one side of the enclosure.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
VTrak J610s, J310s Product Manual  
The rail is designed to slide freely over the plate.  
5. Attach a flange to each end of the rail, with the rail on the opposite side of  
the flange from the two-hole bracket.  
6. Install the rail adjustment screws (included) through the flange into the rail.  
There are four screws for each flange. See Figure 7.  
7. Place the subsystem with mounting rails into your rack system.  
8. Attach the mounting rail assemblies to the outside of the rack posts, using  
the attaching screws from your rack system.  
9. Square the rail assemblies in the rack.  
10. Tighten the adjustment screws and the attaching screws.  
11. Place the VTrak subsystem onto the rails.  
12. Secure the VTrak subsystem to the rack through each handle, using the  
attaching screws from your rack system.  
Figure 6. Sliding flange installation  
Rear (connector end)  
of the subsystem  
VTrak J310s  
Sliding plate  
Screws (6 each side)  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
Rack back  
Figure 7. Mounting rail installation  
Rack front post  
Rail adjustment screw  
Mounting Rail  
Sliding plate  
Rail attaching screw  
(not included)  
Rail attaching screw  
(not included)  
Inside of post  
Inside of post  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VTrak J610s, J310s Product Manual  
Installing Disk Drives  
Populate the VTrak with 3.5-inch SAS or SATA disk drives.  
Install all of the drive carriers into the J610s or J310s enclosure to ensure proper  
airflow, even if you do not populate all the carriers with disk drives.  
Caution  
Use only the counter-sink screws supplied with the J610s or J310s  
unit. Use of other types of screws can damage the adjacent  
drives.  
Figure 8. J610s and J310s unit drive carrier mounting holes  
AAMUX  
Disk Drive Mounting Holes  
Mounting Holes with AAMUX  
Disk Drive Mounting Holes  
without AAMUX  
1. Remove the front bezel (drive door).  
2. Remove a disk drive carrier.  
3. Optional. The AAMUX adapter is recommended for J610s and J310s  
enclosures with two I/O modules, so that both modules can access a SATA  
disk drive.  
Place the optional AAMUX into the disk drive carrier and attach it with the  
four screws.  
Install only the screws supplied with the AAMUX.  
The AAMUX fits into the carrier with the SAS connector at the back. See  
Snug each screw. Be careful not to over tighten.  
4. Carefully lay the drive into the drive carrier at the front, so that the screw  
holes on the bottom line up.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Chapter 2: Installation  
If you installed an AAMUX, lay the SATA disk drive in the carrier and slide it  
so the power and data connectors insert in to the AAMUX. See Figure 10 on  
5. Insert the screws through the holes in the drive carrier and into the bottom of  
the disk drive (see Figure 5).  
Install only the screws supplied with the VTrak.  
Install four screws per drive.  
Snug each screw. Be careful not to over tighten.  
6. Reinstall the drive carrier into the VTrak chassis.  
7. Repeat steps 2 through 5 until all of your disk drives are installed.  
8. Replace the front bezel.  
Figure 9. Drive carrier with SAS disk drive  
SAS Disk Drive  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VTrak J610s, J310s Product Manual  
Figure 10.Drive carrier with SATA disk drive and AAMUX  
SATA Disk Drive  
AAMUX adapter  
Cautions  
SAS connector  
If you plan to operate your VTrak with fewer than a full load of  
disk drives, install all of the drive carriers into the enclosure, to  
ensure proper airflow for cooling.  
A VTrak J610s or J310s carrier is similar in appearance but is  
NOT interchangeable with a VTrak M500f/i/p drive carrier.  
Important  
Be sure each drive is securely fastened to its carrier. Proper  
installation ensures adequate grounding and minimizes vibration.  
Do not install drives with fewer than four screws.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Chapter 2: Installation  
Drive Numbering  
Each disk drive in the J610s and J310s units is identified by a number that  
corresponds to the Port number used for management. See “Link Command” on  
Numbers are stamped above each drive bay for easy indentification.  
Figure 11.VTrak J610s drive slot numbering  
1
2
3
4
8
5
6
7
9
10  
11  
12  
13  
15  
14  
16  
Figure 12.VTrak J310s drive slot numbering  
4
1
2
3
8
5
6
7
12  
9
10  
11  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
VTrak J610s, J310s Product Manual  
Setting Up Data Cable Connections  
The VTrak J610s or J310s unit provides Direct Attached Storage (DAS) support  
to the Host PC.  
Figure 13. VTrak J610s has one or two I/O modules  
I/O module 1  
(default primary)  
I/O module 2  
115200  
115200  
8
N
1
8
N
1
Figure 14.VTrak J310s has one or two I/O modules  
O
I
O
I
115200  
115200  
8
N
1
8
N
1
I/O module 1  
(default primary)  
I/O module 2  
There can be one or two Input Output Modules (I/O modules) on the J610s or  
J310s unit.  
If your J610s or J310s has two I/O modules, I/O module 1 (on the left) is the  
default primary.  
If your J610s or J310s has only one I/O module, that I/O module is the  
default primary.  
Under SAS specifications, both I/O modules are active at the same time. The  
terms primary and secondary are for enclosure management purposes only. To  
verify which I/O module is the default primary, see “Enclosure Command” on  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Chapter 2: Installation  
Figure 15.VTrak J610s and J310s I/O modules have one subtractive-routed  
port and one table-routed port  
115200  
8 N 1  
Subtractive Connector (CN2) LED  
Table Connector (CN1) LED  
I/O Module Status LED  
Each I/O module has one table-routed external receptacle (CN1) and one  
subtractive-routed external receptacle (CN2).  
Note  
SAS HBA cards are User-supplied items. They are not included  
with the VTrak unit.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
VTrak J610s, J310s Product Manual  
Basic DAS Connection  
Figure 16. An example of a basic DAS connection between one Host PC  
and one VTrak J310s unit. The J610s is similar  
Subtractive-Routed Port  
O
I
O
I
115200  
115200  
8
N
1
8
N
1
VTrak J310s  
SFF-8088 external  
4X to 4X SAS cable  
SAS HBA Card  
PC  
The arrangement above is the minimum DAS system with a single SAS HBA  
card in the Host PC. Connect the SAS card to the subtractive-routed port (CN2)  
on the I/O module.  
Use a SFF-8088 4X to 4X external SAS cable with thumbscrew connectors  
(supplied with the J610s or J310s unit).  
Because the Host SAS HBA card is an end device, you can connect it to either of  
the two SAS ports (CN1 or CN2) on the J610s or J310s unit’s I/O module.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
Chapter 2: Installation  
Cascading DAS Connection  
If you are using multiple J610s or J310s units and want to manage them from the  
same SAS HBA card, connect the J610s or J310s units in a cascade.  
Connect the SAS HBA card in the Host PC to the subtractive-routed port (CN2)  
of the I/O module. Use a SFF-8088 4X to 4X external SAS cable (supplied with  
the J610s or J310s unit).  
Connect the I/O module’s table-routed port (CN1) on the first J610s or J310s unit  
to the subtractive-routed port (CN2) on the next J610s or J310s unit.  
You can cascade up to four J610s or J310s units in this manner. You can mix  
J610s and J310s units in the same cascade.  
Figure 17. An example of a cascaded DAS connection between one Host  
PC and two VTrak J310s units. The J610s is similar  
SAS HBA Card  
PC  
CN1  
CN2  
O
I
O
I
115200  
115200  
8
N
1
8
N
1
CN2  
VTrak J310s  
O
I
O
I
115200  
115200  
8
N
1
8
N
1
VTrak J310s  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
VTrak J610s, J310s Product Manual  
Redundant DAS Connection  
The arrangement below is a DAS system with full redundancy.  
Figure 18. An example of a redundant DAS connection between two Host  
PCs and four cascaded VTrak J310s units. The J610s is similar  
SAS HBA Cards  
PC  
PC  
CN2  
O
I
O
I
CN1  
CN2  
115200  
115200  
8
N
1
8
N
1
VTrak J310s  
O
I
O
I
CN1  
CN2  
115200  
115200  
8
N
1
8
N
1
VTrak J310s  
O
I
O
I
CN1  
CN2  
115200  
115200  
8
N
1
8
N
1
VTrak J310s  
O
I
O
I
115200  
115200  
8
N
1
8
N
1
VTrak J310s  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Chapter 2: Installation  
The arrangement requires J610s or J310s units with dual I/O modules and two  
Host PCs with a SAS HBA card in each PC.  
Connect the SAS HBA card in the first Host PC to the subtractive-routed port  
(CN2) on an I/O module of the first J610s or J310s unit.  
Connect the SAS HBA card in the second Host PC to the subtractive-routed port  
(CN2) on the other I/O module of the first J610s or J310s unit.  
Connect the table-routed ports (CN1) on the I/O modules of the first J610s or  
J310s unit to the subtractive-routed ports (CN2) on the I/O modules of the next  
J610s or J310s unit.  
Connect the remaining J610s or J310s units in the same manner. You can mix  
J610s and J310s units in the same cascade.  
Use SFF-8088 to SFF-8088 SAS cables to connect the J610s or J310s units.  
Setting Up Serial Cable Connections  
RS232 serial communication enables the Command Line Interface (CLI) and  
Command Line Utility (CLU) on your PC to monitor and control the VTrak. On  
VTrak, RS232 communication goes through the RJ11 serial connector on each  
controller.  
Figure 19. A serial connector is located on the I/O module. The J310s is  
shown. The J610s is similar  
RJ11Serial  
Connector  
115200  
8
N
1
O
I
O
I
115200  
115200  
8
N
1
8
N
1
To set up a serial cable connection:  
1. Attach the RJ11 end of the RJ11-to-DB9 serial data cable, supplied with the  
VTrak, to the RJ11 serial connector on one of the I/O modules.  
2. Attach a null-modem cable to the DB9 end of the RJ11-to-DB9 serial data  
cable.  
3. Attach the other end of the null-modem cable to a serial port on the Host PC  
or Server.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                       
VTrak J610s, J310s Product Manual  
If your PC has two DB9 COM ports, and your J610s or J310s unit has two I/O  
modules, you can connect a second null-modem cable and RJ11-to-DB9 serial  
data cable the I/O module on the right.  
I/O module is the default primary. To verify which I/O module is the default  
Connecting the Power  
Plug the power cords and switch on both power supplies. When the power is  
switched on, the LEDs on the front of the VTrak will light up.  
Figure 20.VTrak J310s front panel LED display. The J610s is similar  
Power  
FRU Status  
Not Used  
I/O module-1 activity  
I/O module-2 activity  
Heartbeat  
When boot-up is finished and the VTrak is functioning normally:  
The heartbeat LED blinks green once every 3 seconds if one I/O module is  
installed, or twice every 3 seconds if two I/O modules are installed.  
Power and FRU LEDs display green continuously.  
I/O module LEDs flash green if there is activity on that connection.  
There are two LEDs on each Drive Carrier. They report the presence of power  
and a disk drive, and the current condition of the drive.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                 
Chapter 2: Installation  
Disk Status  
Figure 21.VTrak J610s/J310s disk carrier LEDs  
Power/Activity  
Within one minute, the Power/Activity should display Green.  
If there is no disk drive in the carrier, the Disk Status LED and the Power/Activity  
LED will remain dark.  
Setting Up the CLI Connection  
The J610s or J310s unit has a Command Line Interface (CLI) to manage all of its  
functions, including customization. Access the CLI via your PC’s terminal VT100  
or ANSI emulation program, such as Microsoft HyperTerminal.  
With the J610s or J310s unit running and the RJ11-to-DB9 serial data cable with  
a null-modem cable connected to the primary I/O module:  
1. Change your terminal emulation program settings to agree with the  
following:  
Bits per second: 115200  
Data bits: 8  
Parity: None  
Stop bits: 1  
Flow control: none  
2. Start your PC’s terminal emulation program.  
3. Press Enter once to launch the CLI.  
The cli> prompt on your screen indicates that you have a connection and the  
CLI is ready to accept commands.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
VTrak J610s, J310s Product Manual  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Management  
Front Status Indicators (below)  
Drive Status Indicators (page 24)  
I/O Module Status Indicators (page 25)  
CLI Command Set (page 26)  
Front Status Indicators  
Even though the Command Line Interface (CLI) offers comprehensive monitoring  
of VTrak, the LED indicators on the VTrak J610s or J310s unit provide important  
status information.  
When the power is switched on, the LEDs on the front of the VTrak will light up.  
Figure 1. VTrak J310s front panel LED display. The J610s is similar  
Power  
FRU Status  
Not Used  
I/O module-1 activity  
I/O module-2 activity  
Heartbeat  
When boot-up is finished and the VTrak is functioning normally:  
The heartbeat LED blinks green once every 3 seconds if one I/O module is  
installed, or twice every 3 seconds if two I/O modules are installed.  
Power and FRU LEDs display green continuously.  
I/O module LEDs flash green if there is activity on that connection.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
VTrak J610s, J310s Product Manual  
State  
LEDs  
Steady  
Green  
Flashing  
Green  
Dark  
Amber  
Red  
Power  
FRU*  
System Off Normal  
System Off Normal  
1 CU and/or 2 CU and/or  
1 PSU failed 2 PSU failed  
I/O Module  
1 or 2  
No Activity  
Activity  
Heartbeat System Off  
Normal**  
* Field Replacement Unit: Cooling Unit (CU) or Power Supply Unit (PSU)  
** Blinks intermittently.  
Drive Status Indicators  
After a few moments the Power/Activity should display Green.  
If there is no disk drive in the carrier, the Disk Status LED and the Power/Activity  
LED will remain dark.  
Figure 2. VTrak J610s/J310s disk carrier LEDs  
Disk Status  
Power/Activity  
The VTrak spins up the disk drives sequentially in order to equalize power draw  
during start-up. After a few moments the Power/Activity and Disk Status LEDs  
should display green.  
If you have SATA disk drives installed without an AAMUX adapter (see page 16),  
the Power/Activity LED behavior depends on the specific disk drive.  
The Disk Status LED behavior depends on your HBA or RAID controller. See the  
table below.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Chapter 3: Management  
State  
Steady Green Flashing Green  
Drive Present Activity  
HBA/RAID controller determines the LED behavior  
LEDs  
Dark  
No Drive  
Power/Activity*  
Status**  
* Refers to SAS drives or SATA drives with an AAMUX adapter.  
For SATA drives without an AAMUX adapter, LED behavior depends on  
the specific disk drive.  
** Refer to the user documentation for your HBA or RAID controller for this  
information.  
I/O Module Status Indicators  
The VTrak J610s or J310s I/O module has LEDs that indicate activity on each of  
its ports.  
Figure 3. VTrak J610s and J310s I/O Module LEDs  
115200  
8 N 1  
Table Connector (CN2) LED  
Subtractive Connector (CN1) LED  
I/O Module Status LED  
The I/O module status LED shows red at startup. Within 2 or 3 seconds, it turns  
green to indicate that the I/O module is ready.  
State  
LEDs  
Steady  
Green  
Flashing  
Green  
Dark  
Link Down  
Off  
Red  
Connectors  
Link Up  
Activity  
I/O Module  
Status  
Ready  
Starting up*  
* Turns green 2 to 3 seconds after subsystem startup.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
VTrak J610s, J310s Product Manual  
Figure 4. VTrak J610s power supply and fan LEDs  
Power Supply LED  
Fan LED  
The battery LED on the cooling unit has no function on the VTrak J610s and  
J310s models.  
Figure 5. VTrak J310s power supply and fan LEDs  
Power Supply LED  
Fan LED  
O
I
Under normal conditions, the power supply and fan LEDs should display green.  
State  
LEDs  
Dark  
Green  
OK  
Red  
Power supply  
Fan  
Not detected  
Not detected  
Failed  
Failed  
OK  
To check a component’s installation, follow the same procedure as replacing the  
component, except that you reinstall the original component rather than a new  
one. In most cases, this action fixes a bad connection and allows VTrak to detect  
the component. If this action does not correct the problem, replace the unit.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Chapter 3: Management  
CLI Command Set  
The CLI has the following set of commands:  
cable – Specifies the length of cable for optimal signal quality.  
enclosure – Displays full information on the J610s or J310s enclosure and all its  
components, expander addresses and SAS addresses.  
help – Use alone or with a command, such as help enclosure, enclosure -help  
or enclosure -h.  
link – Displays the current status of the Phys (links) and the error counter.  
route – Displays addresses of components through a downstream (expansion)  
connection.  
uptime – Displays the number of days, hours, minutes and seconds since the  
firmware was loaded (the VTrak was started or restarted).  
vpdr – Displays vital product data on field replaceable units.  
? – Use alone or with a command, such as ? enclosure or enclosure -?  
Note  
Commands are case-sensitive. Disable the Caps Lock on your  
keyboard.  
Cable Command  
The Cable command displays the current cable length settings for the two Host  
ports and the Expansion port. The I/O module supports cables from 1 to 5 meters  
in length.  
To view current settings, at the cli> prompt, type cable and press Enter.  
cli>cable  
CN#1 Cable Length = 1 meter  
CN#2 Cable Length = 1 meter  
CN#1 and CN#2 are the external SAS connectors on the I/O module. See  
To change the settings, enter the cable mod command, the connector number  
and cable length. You can specify a cable length from 1 to 8 meters.  
For example, to set the Expansion connector for a 3-meter cable, at the cli>  
prompt, type cable -a mod -s “cn2=3” and press Enter.  
To verify the setting change, at the cli> prompt, type cable and press Enter.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
VTrak J610s, J310s Product Manual  
cli>cable  
CN#1 Cable Length = 1 meter  
CN#2 Cable Length = 3 meter  
Note the cable length change for CN2.  
Enclosure Command  
The Enclosure command:  
Displays information about the J610s or J310s enclosure (below)  
Enables you to make enclosure settings (page 36)  
Information  
The Enclosure command displays information about the J610s or J310s  
enclosure, including:  
Time since power-up  
Enclosure type  
Temperature sensor readings  
Temperature threshold settings  
Voltage sensor readings  
I/O module information  
PSU (power supply) status and  
fan speeds  
Expander SAS addresses  
Attached SAS addresses  
Blower status and fan speeds  
The CLI reports information for the I/O module to which it is connected and for  
the rest of the components in the J310s enclosure.  
Under SAS specifications, both I/O modules are active at the same time. For  
management purposes, the default primary I/O module role is Primary. If a  
second I/O module is present, its role is Secondary. See the arrow below for I/O  
Module Role in the display. Also see “Setting Up Data Cable Connections” on  
In a J610s or J310s unit with two I/O modules, if the primary I/O module fails or is  
removed, the remaining I/O module becomes the default primary I/O module and  
assumes the Primary role. If the other I/O module is repaired or replaced, it  
becomes the secondary I/O module and assumes the Secondary role.  
At the cli> prompt, type enclosure and press Enter.  
cli> enclosure  
-------------------------------------------------------------------------------------  
Time Since Power Up: 1 hour 46 minutes 36 seconds  
Enclosure: J310s-12Bay  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                     
Chapter 3: Management  
I/O Module ID: 1  
Max Num Of I/O Modules: 2  
FwVersion: 1.00.0000.00  
MaxNumOfHDSlots: 12  
MaxNumOfFans: 4  
I/O Module Role: Primary  
MaxNumOfPSUs: 2  
MaxNumOfBlowers: 2  
MaxNumOfTempSensors: 8  
MaxNumOfVoltageSensors: 5  
===========================================  
PSU Status Fan1Speed Fan2Speed  
===========================================  
1
2
Operational  
Operational  
14735 rpm  
15340 rpm  
15037 rpm  
14361 rpm  
===========================================  
Blower Status Speed  
===========================================  
1
Operational  
4017 rpm  
2
Operational  
4066 rpm  
===========================================  
ID Location Temp Reading ID Location Temp Reading  
===========================================  
1. Backplane  
3. Backplane  
32C/89F 2. Backplane  
31C/87F 4. Backplane  
32C/89F  
30C/86F  
5. I/O Module1 40C/104F 6. I/O Module1 30C/86F  
7. I/O Module2 36C/96F 8. I/O Module2 28C/82F  
Thermal Management: Enabled  
Allows to shut down the system when critical temperature is reached: Yes  
Current minimum fan speed setting: medium low  
Enclosure Temp Threshold: 61C/141F (critical) 51C/123F (warning)  
Controller Temp Threshold: 71C/159F (critical) 61C/141F (warning)  
===========================================  
VoltageSensor Voltage  
===========================================  
1
2
3
4
5
3.3V  
5.2V  
5.2V  
12.5V  
1.2V  
Expander SAS Address:  
SAS Base Addr:50 00 15 5D 21 AB 02 00  
SSP SAS Addr: 50 00 15 5D 21 AB 02 3E  
SMP SAS Addr: 50 00 15 5D 21 AB 02 3F  
Attached SAS Address:  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VTrak J610s, J310s Product Manual  
D01 SAS Addr: 50 00 15 E0 11 4E 5E B2  
D02 SAS Addr: 50 00 15 E0 11 4E 80 C2  
D03 SAS Addr: 50 00 15 E0 11 4C 22 02  
D04 SAS Addr: 50 00 15 E0 11 4D E2 22  
D05 SAS Addr: 50 00 15 E0 11 4D 8F B2  
D06 SAS Addr: 50 00 15 E0 11 4D D0 62  
D07 SAS Addr: 50 00 15 E0 11 4D DE E2  
D08 SAS Addr: 50 00 15 E0 11 4D 8E F2  
D09 SAS Addr: 50 00 15 E0 11 4C 97 62  
D10 SAS Addr: 50 00 15 E0 11 4C 36 62  
D11 SAS Addr: No Device Attached  
D12 SAS Addr: No Device Attached  
CN1 SAS Addr: 50 06 05 B0 00 01 69 64  
CN2 SAS Addr: No Device Attached  
CN3 SAS Addr: 50 00 15 5D 21 AA 12 3F  
Settings  
The Enclosure command enables you to make settings for the enclosure. The  
J310s is shown. The J610s is similar.  
Enclosure Critical Temperature – 51°C (123°F) to 61°C (141°F), measured  
at the backplane  
Enclosure Warning Temperature – 10°C (50°F) to 51°C (123°F), measured  
at the backplane  
Controller Critical Temperature – 61°C (141°F) to 71°C (160°F), measured  
inside the I/O module  
Controller Warning Temperature – 10°C (50°F) to 61°C (141°F), measured  
inside the I/O module  
Thermal Management – Monitors enclosure temperature, adjusts fan  
speeds, displays red LED on cooling unit when a fan fails  
Automatic Shutdown – Shuts down the J310s when it reaches the enclosure  
or controller critical temperature  
Minimum Fan Speed – Specifies the minimum fan speed when the J310s  
reaches enclosure or controller warning temperature  
To set the enclosure critical temperature to 61°C (141°F), at the cli> prompt, type  
enclosure -a mod -s “enc_critical=61” and press Enter.  
To enable Thermal Management, at the cli> prompt, type enclosure -a mod -s  
“thermalmanager=1” and press Enter.  
For this command, a 1 enables and a 0 disables.  
To enable Automatic Shutdown, at the cli> prompt, type enclosure -a mod -s  
“allowshutdown=1” and press Enter.  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Chapter 3: Management  
For this command, a 1 enables and a 0 disables.  
To set the minimum fan speed to medium high, at the cli> prompt, type  
enclosure -a mod -s “minfanspeed=3” and press Enter.  
For this command, 1 means low, 2 means medium-low, 3 means medium-high,  
and 4 means high. The actual speed depends on the fan manufacturer.  
For a complete list of Enclosure commands, at the cli> prompt, type enclosure  
-h and press Enter.  
Help Command  
The J610s and J310s CLI uses the standard Unix online help system.  
For general help, at the cli> prompt, type help and press Enter.  
For help with a specific function, type the name of the function and help or -h. For  
example:  
At the cli> prompt, type cable -h and press Enter.  
At the cli> prompt, type cable -help and press Enter.  
At the cli> prompt, type help cable and press Enter.  
Link Command  
The Link command displays information about the J310s links, including:  
Link Status  
Link Counter  
At the cli> prompt, type link and press Enter.  
Link Status:  
Port  
D01  
D02  
D03  
D04  
D05  
D06  
D07  
D08  
D09  
D10  
D11  
D12  
CN1  
Type  
SAS  
SAS  
SAS  
SAS  
SAS  
SAS  
SAS  
SAS  
SAS  
SAS  
----  
Rate  
3.0G  
3.0G  
3.0G  
3.0G  
3.0G  
3.0G  
3.0G  
3.0G  
3.0G  
3.0G  
----  
Init  
OK  
OK  
OK  
OK  
OK  
OK  
OK  
OK  
OK  
OK  
----  
----  
OK  
Dev  
End  
End  
End  
End  
End  
End  
End  
End  
End  
End  
----  
Link  
----  
----  
----  
----  
----  
----  
----  
----  
----  
----  
----  
----  
----  
PRdy  
Rdy  
Rdy  
Rdy  
Rdy  
Rdy  
Rdy  
Rdy  
Rdy  
Rdy  
Rdy  
----  
P 0  
P 1  
P 2  
P 3  
P 4  
P 5  
P 6  
P 7  
P 8  
P 9  
P10  
P11  
P12  
----  
SAS  
----  
3.0G  
----  
End  
----  
Rdy  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
VTrak J610s, J310s Product Manual  
P13  
P14  
P15  
P16  
P17  
P18  
P19  
CN1  
CN1  
CN1  
CN2  
CN2  
CN2  
CN2  
SAS  
SAS  
SAS  
----  
----  
----  
----  
3.0G  
3.0G  
3.0G  
----  
----  
----  
OK  
OK  
OK  
----  
----  
----  
----  
End  
End  
End  
----  
----  
----  
----  
----  
----  
----  
----  
----  
----  
----  
Rdy  
Rdy  
Rdy  
----  
----  
----  
----  
----  
Port:Port Id  
Type:SAS  
Rate:Rate 3G  
Init:Init Passed Dev:Device Type Link:Link Connected  
PRdy:Phy Ready  
The following items are reported in the table above:  
Link number – The links are Phys, numbered P0 through P23  
Port number – Each disk-drive slot has a Phy. Each connector has 4 Phys.  
D01 though D12 are disk-drive slot numbers. See “Drive Numbering” on  
CN1 and CN2 are the external SAS connectors on the I/O module. See  
Drive Type – SAS  
Data Rate – 3.0 Gb/s  
Device Type – End means an end device, Exp means an expansion device  
Link Connection – Normally, ---- is displayed. If there is a connection at the  
moment the link command runs, it will display CONN  
Phy Ready Status – If the port is ready, it will display Rdy  
Link Counter:  
InDW  
DsEr  
DwLo  
PhRe  
CoVi  
PRBS  
PhCh  
P 0 ---------- ---------- ---------- ---------- ---------- ---------- 0x01  
P 1 ---------- ---------- ---------- ---------- ---------- ---------- 0x01  
P 2 ---------- ---------- ---------- ---------- ---------- ---------- 0x01  
P 3 ---------- ---------- ---------- ---------- ---------- ---------- 0x01  
P 4 ---------- ---------- ---------- ---------- ---------- ---------- 0x01  
P 5 ---------- ---------- ---------- ---------- ---------- ---------- 0x0B  
P 6 ---------- ---------- ---------- ---------- ---------- ---------- 0x01  
P 7 ---------- ---------- ---------- ---------- ---------- ---------- 0x01  
P 8 ---------- ---------- ---------- ---------- ---------- ---------- 0x01  
P 9 ---------- ---------- ---------- ---------- ---------- ---------- 0x01  
P10 ---------- ---------- ---------- ---------- ---------- ---------- ----------  
P11 ---------- ---------- ---------- ---------- ---------- ---------- ----------  
P12 ---------- ---------- ---------- ---------- ---------- ---------- 0x01  
P13 0x0F  
0x0E  
0x01  
---------- 0x06  
0x0C  
0x02  
P14 ---------- ---------- ---------- ---------- ---------- ---------- 0x01  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Chapter 3: Management  
P15 ---------- ---------- ---------- ---------- ---------- ---------- 0x01  
P16 ---------- ---------- ---------- ---------- ---------- ---------- ----------  
P17 ---------- ---------- ---------- ---------- ---------- ---------- ----------  
P18 ---------- ---------- ---------- ---------- ---------- ---------- ----------  
P19 ---------- ---------- ---------- ---------- ---------- ---------- ----------  
InDW:Invalid Dword Count DsEr:Disparity Err Count  
DwLo:Dword Sync Loss Count  
PhRe:Phy Reset Problem Count CoVi:Code Violations Cnt  
PRBS:PRBS Error Count  
PhCh:Phy Change Count  
The following items are reported in the table above. All counts are hexadecimal:  
Link number – Links are Phys, numbered P0 through P23  
Invalid D-word Count  
Disparity Error Count  
Phy Reset Problem Count  
Code Violation Count  
Pseudo-Random Bit-Stream Error Count  
Phy Change Count  
If the count is zero, the counter shows dashes (----------). The fact that errors  
occur does not necessarily indicate a problem or that the J610s or J310s unit is  
malfunctioning.  
An individual error count incrementing at intervals of less than six minutes  
indicates a possible problem and requires further investigation.  
To clear the link error count, at the cli> prompt, type link -a clear and press  
Enter.  
Route Command  
Use this command to show the SAS addresses of the devices in your domain.  
At the cli> prompt, type route and press Enter.  
Routing Table Mapping:  
Entry# SAS Address  
PortID CnID NextEntry NextValid  
-------------------------------------------------------------------------------------  
0083 500000E01122C533 0x10  
0121 500000E01122C4A3 0x10  
0226 500000E01122C513 0x10  
0244 500000E011246263 0x10  
0358 500000E011231F43 0x10  
0466 500000E0112770B3 0x10  
CN1  
CN1  
CN1  
CN1  
CN1  
CN1  
----  
----  
----  
----  
----  
----  
0
0
0
0
0
0
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
VTrak J610s, J310s Product Manual  
0488 500000E01122C0F3 0x10  
CN1  
CN1  
CN1  
CN1  
CN1  
CN1  
CN1  
----  
----  
----  
----  
----  
----  
----  
0
0
0
0
0
0
0
0519 500000E01122C493 0x10  
0731 500000E01122C5B3 0x10  
0751 500000E01122C5C3 0x10  
0851 500000E01122C583 0x10  
0864 5000155D21AB433E 0x10  
0945 500000E0112313C3 0x10  
The route command displays SAS addresses that are attached to one of the  
external ports on the J610s or J310s unit. Six items are reported:  
Entry Number – Arbitrary numbers, listed in sequence  
SAS Address – Of the disk drive or other component  
Port ID – Phy numbers, shown in hexadecimal  
Connector ID – One of two external SAS ports on the J610s or J310s unit  
Next Entry – The next entry number for the same SAS address  
Next Valid – 1 means there is another one. 0 means this is the last one  
This device is connected to the J610s or J310s unit through connector CN1. See  
page 21 for a diagram of connectors on the I/O module.  
If you type route at the cli> prompt and press Enter, then see the following  
message:  
No SAS Routing Entry Exists  
...it indicates that no devices are found on the table-routed (CN2) connector.  
Uptime Command  
The uptime command informs you of the elapsed period of time since the J610s  
or J310s unit was powered on.  
To display uptime, at the cli> prompt, type uptime and press Enter.  
cli>uptime  
System has been running 1 hour 46 minutes 35 seconds  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Chapter 3: Management  
VPDR Command  
The vpdr command displays vital product data on the major components of the  
J610s or J310s unit. There are six components that report vital product  
information.  
1 – Controller (I/O module)  
2 – Power Supply 1  
3 – Cooling Unit 1  
4 – Power Supply 2  
5 – Cooling Unit 2  
6 – Backplane  
Specify the component by its number. For example, to display vital product data  
for the controller (I/O module), at the at the cli> prompt, type vpdr -i 1 and press  
Enter.  
cli>vpdr -i 1  
Board ID  
: 1  
OEM Name : IOC  
OEM Model : J310s  
Mfg Part  
Mfg SN  
Mfg Rev  
Mfg Date  
WWN  
: IOC-J310s-01  
: S0026  
: A2R4  
: 2005:08:18  
: 20 00 00 01 55 D2 1A A1  
? Command  
The VTrak CLI uses the standard Unix online help system.  
For the command usage of a particular function, type the name of the function  
followed by ?. For example, at the cli> prompt, type cable -? and press Enter.  
For help with a particular function, type ? followed by the name. For example, at  
the cli> prompt, type ? cable and press Enter.  
The result of typing ? followed by the name is the same as typing help followed  
by the name.  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
VTrak J610s, J310s Product Manual  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: Support  
Frequently Asked Questions (below)  
Limited Warranty (page 47)  
Returning product for repair (page 48)  
Frequently Asked Questions  
What kind of disk drives can I use with J610s and J310s?  
The J610s and J310s support 3.5-inch Serial Attached SCSI (SAS) disk  
drives and SATA II disk drives. If you use SATA disk drives, on a VTrak with  
two I/O modules, you must also install an AAMUX adapter for each SATA  
drive.  
How can I tell when the J610s or J310s unit has fully booted?  
When the J610s or J310s unit is fully booted up, the Power and FRU LEDs  
will light up green. The heartbeat LED blinks green once every 3 seconds if  
one I/O module is installed, or twice every 3 seconds if two I/O modules are  
installed.  
How can I tell my CLI connection is to the primary default I/O module?  
After you establish the CLI connection, type Enclosure and press Enter.  
Look at the top of the display for an item called I/O Module Role. If the Role  
is Primary, you are connected to the default primary I/O module. If the Role  
is Secondary, you are connected to the default secondary.  
What happens if a disk drive fails?  
Depending on the nature of the failure, the failed drive the drive might not  
appear in the CLI, or the failed drive might appear with an error, when you  
run the enclosure command (see page 34) or the link command (see  
page 37).  
Can I hot-swap a failed drive with a new one?  
Yes. Disk drives are hot-swappable on the J610s and J310s units.  
Can the J610s and J310s run using just one power supply?  
Yes, it is possible to run J610s and J310s unit on a single power supply.  
J610s and J310s units ship with two power supplies. The J610s or J310s  
unit will continue running if one of the power supply fails. But deliberately  
leaving one power supply off negates this advantage.  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                 
VTrak J610s, J310s Product Manual  
In addition, leaving one power supply off reduces air flow through the J610s  
or J310s enclosure and can contribute to overheating. Always switch on both  
power supplies if your J610s or J310s unit has two.  
Contacting Technical Support  
Promise Technical Support provides several support options for Promise users to  
access information and updates. We encourage you to use one of our electronic  
services, which provide product information updates for the most efficient service  
and support.  
Important  
Promise offers 24x7 live technical support (in English only) for  
registered owners of VTrak products. To register, point your  
browser to:  
If you decide to contact us, please have the following information available:  
Product model and serial number  
BIOS, firmware and driver version numbers  
A description of the problem / situation  
System configuration information, including: motherboard and CPU type,  
hard drive model(s), SAS/SATA/ATA/ATAPI drives & devices, and other  
controllers.  
Technical Support Services  
Promise Online™ Web Site  
(technical documents, drivers, utilities, etc.)  
(online request form)  
Promise Online™ eSupport  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Chapter 4: Support  
United States  
E-mail Support  
Fax Support  
(408) 228-1097 Attn: Technical Support  
(408) 228-1400 option 4  
Phone Support  
If you wish to write us for  
support:  
Promise Technology, Inc.  
580 Cottonwood Drive  
Milpitas, CA 95035, USA  
The Netherlands  
E-mail Support  
Fax Support  
+31 (0) 40 256 9463 Attn: Technical Support  
+31 (0) 40 235 2600  
Phone Support  
If you wish to write us for  
support:  
Promise Technology Europe B.V.  
Science Park Eindhoven 5542  
5692 EL Son, The Netherlands  
Germany  
E-mail Support  
Fax Technical Support  
+49 (0) 2 31 56 76 48 - 29  
Attn: Technical Support  
Phone Technical Support  
+49 (0) 2 31 56 76 48 - 10  
If you wish to write us for  
support:  
Promise Technology Germany  
Europaplatz 9  
44269 Dortmund, Germany  
Italy  
E-mail Support  
Fax Support  
0039 06 367 12400 Attn: Technical Support  
0039 06 367 12626  
Phone Support  
If you wish to write us for  
support:  
Promise Technology Italy  
Piazza del Popolo 18  
00187 Roma, Italia  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VTrak J610s, J310s Product Manual  
Taiwan  
E-mail Support  
Fax Support  
+886 3 578 2390 Attn: Technical Support  
+886 3 578 2395 (ext. 8811)  
Phone Support  
If you wish to write us for  
support:  
Promise Technology, Inc.  
2F, No. 30, Industry E. Rd. IX  
Science-based Industrial Park  
Hsin-Chu 30075, Taiwan, (R.O.C.)  
China  
E-mail Support  
Fax Support  
+86-10-8857-8015 Attn: Technical Support  
+86-10-8857-8085/8095  
Phone Support  
If you wish to write us for  
support:  
Promise Technology China  
Room 1205, Tower C  
Webok Time Center, No.17  
South Zhong Guan Cun Street  
Hai Dian District, Beijing 100081, China  
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: Support  
Limited Warranty  
Promise Technology, Inc. (“Promise”) warrants that for three (3) years from the  
time of the delivery of the product to the original end user:  
a) the product will conform to Promise’s specifications;  
b) the product will be free from defects in material and workmanship under  
normal use and service.  
This warranty:  
a) applies only to products which are new and in cartons on the date of  
purchase;  
b) is not transferable;  
c) is valid only when accompanied by a copy of the original purchase  
invoice.  
d) Is not valid on spare parts, fans, and power supplies  
This warranty shall not apply to defects resulting from:  
a) improper or inadequate maintenance, or unauthorized modification(s),  
performed by the end user;  
b) operation outside the environmental specifications for the product;  
c) accident, misuse, negligence, misapplication, abuse, natural or  
personal disaster, or maintenance by anyone other than a Promise or a  
Promise-authorized service center.  
Disclaimer of other warranties  
This warranty covers only parts and labor, and excludes coverage on software  
items as expressly set above.  
Except as expressly set forth above, Promise DISCLAIMS any warranties,  
expressed or implied, by statute or otherwise, regarding the product, including,  
without limitation, any warranties for fitness for any purpose, quality,  
merchantability, non-infringement, or otherwise. Promise makes no warranty or  
representation concerning the suitability of any product for use with any other  
item. You assume full responsibility for selecting products and for ensuring that  
the products selected are compatible and appropriate for use with other goods  
with which they will be used.  
Promise DOES NOT WARRANT that any product is free from errors or that it will  
interface without problems with your computer system. It is your responsibility to  
back up or otherwise save important data before installing any product and  
continue to back up your important data regularly.  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
VTrak J610s, J310s Product Manual  
No other document, statement or representation may be relied on to vary the  
terms of this limited warranty.  
Promise’s sole responsibility with respect to any product is to do one of the  
following:  
a) replace the product with a conforming unit of the same or superior  
product;  
b) repair the product.  
Promise shall not be liable for the cost of procuring substitute goods, services,  
lost profits, unrealized savings, equipment damage, costs of recovering,  
reprogramming, or reproducing of programs or data stored in or used with the  
products, or for any other general, special, consequential, indirect, incidental, or  
punitive damages, whether in contract, tort, or otherwise, notwithstanding the  
failure of the essential purpose of the foregoing remedy and regardless of  
whether Promise has been advised of the possibility of such damages. Promise  
is not an insurer. If you desire insurance against such damage, you must obtain  
insurance from another party.  
Some states do not allow the exclusion or limitation of incidental or consequential  
damages for consumer products, so the above limitation may not apply to you.  
This warranty gives specific legal rights, and you may also have other rights that  
vary from state to state. This limited warranty is governed by the State of  
California.  
Your Responsibilities  
You are responsible for determining whether the product is appropriate for your  
use and will interface with your equipment without malfunction or damage. You  
are also responsible for backing up your data before installing any product and  
for regularly backing up your data after installing the product. Promise is not  
liable for any damage to equipment or data loss resulting from the use of any  
product.  
Returning Product For Repair  
If you suspect a product is not working properly, or if you have any questions  
about your product, contact our Technical Support Staff through one of our  
Technical Services, making sure to provide the following information:  
Product model and serial number (required)  
Return shipping address  
Daytime phone number  
Description of the problem  
Copy of the original purchase invoice  
48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Chapter 4: Support  
The technician will assist you in determining whether the product requires repair.  
If the product needs repair, the Technical Support Department will issue an RMA  
(Return Merchandise Authorization) number.  
Important  
Obtain an RMA number from Technical Support before you return  
the product and write the RMA number on the label. The RMA  
number is essential for tracking your product and providing the  
proper service.  
Return ONLY the specific product covered by the warranty (do not ship cables,  
manuals, diskettes, etc.), with a copy of your proof of purchase to:  
USA and Canada:  
Other Countries:  
Promise Technology, Inc.  
Customer Service Dept.  
Attn.: RMA # ______  
47654 Kato Road  
Fremont, CA 94538  
Return the product to your dealer  
or retailer.  
Contact them for instructions  
before shipping the product.  
You must follow the packaging guidelines for returning products:  
Use the original shipping carton and packaging  
Include a summary of the product’s problem(s)  
Write an attention line on the box with the RMA number  
Include a copy of proof of purchase  
You are responsible for the cost of insurance and shipment of the product to  
Promise. Note that damage incurred due to improper transport or packaging is  
not covered under the Limited Warranty.  
When repairing returned product(s), Promise may replace defective parts with  
new or reconditioned parts, or replace the entire unit with a new or reconditioned  
unit. In the event of a replacement, the replacement unit will be under warranty  
for the remainder of the original warranty term from purchase date, or 30 days,  
whichever is longer.  
Promise will pay for standard return shipping charges only. You will be required  
to pay for any additional shipping options (such as express shipping).  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
VTrak J610s, J310s Product Manual  
50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix A: Second I/O Module  
The VTrak J610s and J310s units ship with one or two I/O modules. If your J610s  
or J310s came with only one I/O module, you can upgrade by installing a second  
I/O module. The following instructions describe how to install a second I/O  
module.  
To install a second I/O module in a VTrak J610s or J310s unit:  
1. Power down the J610s or J310s unit.  
2. Press the release button on the dummy I/O module, pull the handle down  
and remove the dummy I/O module from the enclosure.  
3. Slide the new I/O module into the slot.  
4. Gently push the new I/O module all the way into the slot until the handle  
locks.  
5. Connect your data cables to the new I/O module.  
See page 20 for more information.  
6. Optional. Connect your serial cable to the second I/O module.  
See page 25 for more information.  
7. Power up the J610s or J310s unit.  
To verify proper installation and function, run the enclosure command in the CLI.  
Because the new I/O module is installed in the right slot, it will automatically take  
the Standby role in the CLI screen. See page 34 for more information.  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
VTrak J610s, J310s Product Manual  
52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
Symbols  
? command 41  
D
DAS  
basic 22  
cascade 23  
redundant 24  
A
AAMUX adapter 16, 18, 30  
About This Manual 1  
Attached SAS addresses 34  
automatic shutdown setting 36  
supported 20  
Data cable connections 20  
Basic DAS 22  
Cascading DAS 23  
Redundant DAS 24  
Dimensions 7  
B
blower status 34  
disk drives  
drive carriers 18  
hot-swappable 43  
install 16  
C
cable  
command 33  
null modem 25, 27  
RJ11-to-DB9 25, 27  
CE statement 7  
Certifications 7  
CN1, CN2 21, 22, 25  
Command  
numbering 19  
supported 16, 43  
E
enclosure command 34, 43  
end device 22  
Environmental 6  
error counts 39  
cable 33  
ESD Warning 9  
expander SAS addresses 34  
CLI 33  
enclosure 34, 43  
help 37  
F
route 39  
FCC statement 7  
Features and Benefits 5  
Frequently Asked Questions 43  
FRU LED 26, 29  
set 33  
uptime 40  
vpdr 41  
component data 41  
Connection  
CLI 27  
H
Heartbeat LED 26, 29  
help command 37  
data cables 20  
power 26  
serial 25  
cooling unit LED 32  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VTrak J610s, J310s Product Manual  
I
P
I/O module 10, 26  
add second module 51  
default primary 20  
dual 25  
Phy ready status 38  
port  
CN1, CN2 21, 22, 25  
number 38  
subtractive-routed 21, 22, 23,  
SAS ports 22, 23  
table-routed 21, 23  
Power  
L
LEDs  
connection 26  
cooling unit 32  
disk drives 30  
drive carrier 26  
fan 32  
front 29  
front panel 26, 29  
FRU 29  
requirements 6  
power supply 10  
LED 32  
single 43  
status 34  
primary I/O module 20  
heartbeat 29  
I/O module 31  
power 29  
R
rackmount  
power supply 32  
link  
E310f/s 13  
E610f/s 11  
command 37, 43  
connection 38  
number 38  
status and counter 37  
regulatory statements 7  
RJ11-to-DB9  
connector 25  
RMA number 49  
role, I/O module 34, 43, 51  
route command 39  
routing table mapping 39  
RS232 serial communication 25  
M
mapping, routing table 39  
minimum fan speed setting 36  
N
S
SAS  
null-modem cable 25, 27  
address 39  
O
end device 22  
expander address 34  
screws, counter-sink 16  
Operating Systems, supported 6  
54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
Serial cable connections 25, 27  
setting  
U
Unpack the VTrak 9  
automatic shutdown 36  
minimum fan speed 36  
temperature 36  
uptime command 40  
V
thermal management 36  
Specifications 6  
vital product data 41  
voltage sensors 34  
vpdr command 41  
VTrak  
Status Indicators  
disk drives 30  
front 29  
rackmount E310f/s 13  
rackmount E610f/s 11  
returning for repair 48  
unpack 9  
I/O module 31  
status, phy 38  
subtractive-routed port 21, 22, 23,  
warranty 7  
T
W
table-routed port 21, 23, 25  
Technical Support 44  
temperature  
Warranty 47  
sensors 34  
settings 36  
thermal management setting 36  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VTrak J610s, J310s Product Manual  
56  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Peerless Industries TV Mount STL670 User Manual
PhatNoise Car Stereo System KDC W6031 User Manual
Philips Coffeemaker HD 5400 User Manual
Philips CRT Television 14PT3336 User Manual
Philips Stereo Amplifier TDA1519C User Manual
Poulan Lawn Mower 183247 User Manual
Presonus Audio electronic Stereo System DigiMax FS User Manual
ProForm Home Gym PFEX742071 User Manual
Proline Ventilation Hood PLS1440 User Manual
Proline Ventilation Hood PLS1570 User Manual