Precisionaire Air Cleaner Surelock B User Manual

®
Surelock-B  
Bolt Lock HEPA Filter Housing  
F O R E M O S T I N A I R F I LT R AT I O N  
Bulletin PB1603-1206  
General  
Construction  
Surelock-B Side Access HEPA Filter Housings are  
designed to accept all gasket-seal HEPA filters. They  
are all-welded factory-assembled flanged units suit-  
able for installation in a duct on the downstream side  
of an air handling unit.  
Housings are 27 in. deep in the direction of air flow  
and are constructed of 14 ga. galvanized steel.  
Upstream and downstream outwardly-turned flanges  
are furnished for attachment to the ductwork. Each  
HEPA filter is secured in place by four positive-  
pressure spring-loaded swing-arm assemblies which  
maintain continuous pressure on the filter gasket  
against the sealing surfaces.  
Housings guarantee filter system efficiency equal to  
the efficiency of the individual filters. Optional prefilter  
tracks are designed to accommodate 2 in. pleated  
panel filters with efficiency ranges up to 50% per  
ASHRAE Standard 52.1 dust-spot test methods. Both  
prefilters and primary HEPA filters are serviceable  
through gasketed access doors.  
Optional prefilter tracks are galvanized steel furnished  
with a pile gasket. Hinged/removable access doors  
are furnished with rubber sealing gaskets and posi-  
tive-pressure adjustable latches with easy-grip knobs  
on the air entering and the air leaving sides to create  
an airtight seal. Metal-to-metal joints are welded to  
ensure a leak-proof assembly at + 8 in. w.g. internal  
pressure.  
Options  
• Prefilter tracks  
• Double-walled insulation on doors only or on the  
entire housing  
Versatility  
• Aluminum or 304 stainless steel housing  
construction  
Surelock-B Housings are designed to accommodate  
Alpha 95 filters with a DOP efficiency of 95% and  
Alpha Cell and Alpha 2000 filters with DOP efficien-  
cies of 99.97%, 99.99% and 99.999%. Standard  
housings will accept nominal 12 in. deep 24 in. x 24  
in. and 24 in. x 12 in. filters from one filter high and  
one filter wide to four filters high and six filters wide. If  
large units are not practical to install, smaller units are  
available with modifications to facilitate stacking.  
• Modifications for high temperature (400 °F continu-  
ous, 500 °F intermittent duty)  
• Swing-arm assemblies for 6 in. deep HEPA filters  
Important Features  
• Units are constructed of durable 14 ga.  
galvanized steel  
• All metal-to-metal joints are welded for  
leak-tightness at + 8 in. w.g. internal pressure  
• Prefilter tracks and doors are fully gasketed  
• Positive-pressure adjustable door latches  
create an air-tight seal  
• Spring-loaded swing-arm assemblies hold  
HEPA filters to sealing surface  
• Access doors are hinged/removable for easy  
service  
Flanders Filters - Foremost in Air Filtration  
Toll Free: 1-800-637-2803  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
A
Surelock Features  
B
A. 14 ga. galvanized steel construction  
B. 1-1/2 in. easy-grip UV-resistant  
knobs on positive-pressure  
adjustable door latches  
C
C. Hinged/removable doors  
D. Optional 2 in. pre-filter tracks  
E. All metal joints welded  
F. Filter sealing surface  
D
E
F
A
A. Standing flange for duct connection  
B. Spring loaded swing-arm filter clamping assembly  
B
Filter Usage and Housing Weight  
Height Filters  
Code Weight  
(lb)  
Width Code  
10W  
15W  
--  
20W  
25W  
--  
30W  
35W  
40W  
45W  
--  
50W  
--  
55W  
--  
60W  
--  
05H  
10H  
15H  
20H  
25H  
30H  
35H  
40H  
Filters  
Weight  
Filters  
Weight  
Filters  
Weight  
Filters  
Weight  
Filters  
Weight  
Filters  
Weight  
Filters  
Weight  
Filters  
Weight  
1C  
110  
2C  
140  
2A  
3C  
160  
3A  
-
4C  
180  
1A  
1A-1C  
205  
--  
2A-1C  
275  
--  
3A-1C  
332  
--  
4A  
4A-1C  
385  
--  
5A  
408  
5A-1C  
465  
--  
6A  
510  
165  
1A-1C  
185  
2A  
240  
2A-2C  
250  
4A  
300  
3A-3C  
310  
6A  
360  
4A-4C  
390  
5A-5C  
450  
6A-6C  
560  
2A-2C  
250  
--  
4A-2C  
318  
--  
6A-2C  
395  
--  
8A  
8A-2C  
446  
--  
10A  
10A-2C  
546  
12A  
215  
2A-1C  
225  
3A  
267  
4A-2C  
318  
6A  
350  
6A-3C  
370  
9A  
410  
475  
615  
8A-4C  
500  
10A-5C  
565  
--  
12A-6C  
712  
3A-3C  
312  
--  
6A-3C  
392  
--  
9A-3C  
470  
--  
12A  
506  
12A-3C  
545  
15A  
15A-3C  
600  
18A  
270  
3A-1C  
282  
4A  
350  
6A-2C  
385  
8A  
435  
9A-3C  
470  
12A  
555  
585  
742  
12A-4C  
612  
--  
15A-5C  
765  
--  
18A-6C  
945  
4A-4C  
392  
8A-4C  
502  
12A-4C  
612  
16A  
670  
16A-4C  
758  
20A  
20A-4C  
922  
24A  
340  
446  
845  
985  
(1) Filters/Weight: Top letter/number combination indicates the number of and nominal face size of filters required  
to fill the unit. “A” stands for nominal 24” x 24” filter. “C stands for nominal 24” x 12” filter. Bottom number indi-  
cates the approximate weight of the housing EMPTY. Add approximately 32 lb per 24 in. x 24 in. filter and 15 lb  
per 24 in. x 12 in. filter plus 2 lb per prefilter to determine approximate weight when loaded with filters.  
• Standard housing depth is 12”  
Flanders Filters - Foremost in Air Filtration  
Toll Free: 1-800-637-2803  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Standard construction: All-welded 14 gauge (.078 in.) galvanized steel housing and doors, leak -tight at + 8 in. w.g.  
2. Flange dimensions are typical for both top and bottom of openings.  
3. Each HEPA filter is individually secured and clamped in place with four spring-loaded swing arm assemblies.  
4. Maximum operating temperature for standard Surelock Housings is 250 °F. High temperature Surelock housings are avail-  
able for 400 °F continuous and 500 °F intermittent duty. These units are furnished with silicone sponge gasketing on the  
doors and stainless steel springs on the swing arm assemblies.  
Guide Specifications  
1.0 Filter Housings  
2.3 Each HEPA filter shall be secured in place with  
four spring-loaded swing-arm assemblies to pro-  
vide positive sealing of the HEPA filter to the  
mounting surface.  
1.1 Side access HEPA filter housings shall be  
Surelock-B as manufactured by Flanders.  
1.2 Unit shall be a factory-assembled air-tight housing  
with upstream and downstream outwardly-turned  
flanges for installation in the ductwork.  
2.4 Access doors shall be hinged/removable and shall  
have continuous neoprene gasketing on the  
perimeter. They shall be equipped with positive-  
pressure adjustable latches with easy-grip knobs.  
1.3 Housings shall be suitable for operation + 8 in. w.g.  
internal static pressure.  
3.0 Features  
2.0 Construction  
3.1 Model number and capacities shall be as specified  
and/or shown on the drawings.  
2.1 Housing construction shall be of 14 ga. galvanized  
steel. Metal-to-metal joints shall be welded.  
3.2 Provide options as specified.  
2.2 Prefilter tracks, if required, shall be galvanized  
steel and incorporate a pile gasket to ensure seal-  
ing of the filter to the track.  
®
REPRESENTED BY:  
Flanders Filters, Inc.  
531 Flanders Filter Road  
Washington, NC 27889  
Phone: (252) 946-8081  
Toll Free: (800) 637-2803  
Fax: (252) 946-3425  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Philips CRT Television 15PT2966 User Manual
Philips Digital Photo Frame 10FFECME User Manual
Philips Portable CD Player AX5200 User Manual
Philips Telephone CD290 User Manual
Philips TV Antenna SDV6122T 27 User Manual
Philips TV Mount SQM6375 27 User Manual
Pioneer Car Amplifier PRS D4100F User Manual
Polar Watch RCX5 User Manual
Poulan Chainsaw PP3816 AV PP4218 AV User Manual
ProForm Treadmill PFTL790080 User Manual