R
Instruction Manual
Manual de Instrucciones
Manuel d’Instructions
BVM200
IMPORTANT MANUAL -- Do not throw away
MANUAL IMPORTANTE -- No lo descarte
MANUEL IMPORTANT -- À Conserver
WARNING:
Read and follow all Safety Rules and Operating Instructions before
using this product. Failure to do so can result in serious injury.
ADVERTENCIA:
Lea el manual de instrucciones y siga todas las advertencias e
instrucciones de seguridad. El no hacerlo puede resultar en lesiones
graves.
AVERTISSEMENT:
Veuillez lire le manuel d’instructions et bien respecter tous les
avertissements et toutes les instructions de sécurité. Tout défaut
de le faire pourrait entraîner des blessures graves.
Electrolux Home Products
104 Warren Road
Augusta, GA 30907
Copyright E2004 Electrolux Home Products, Inc.
530163805
2/2/04
Download from Www.Somanuals.com. All Manuals Search And Download.
plug disconnected. Keep vents and dis-
charge tubes free of debris which can ac-
cumulate and restrict proper air flow.
Never place any object in the air intake
opening as this could restrict proper air flow
and cause damage to the unit.
Never use for spreading chemicals, fertil-
izers, or other substances which may con-
tain toxic materials.
SPECIAL NOTICE: Exposure to vibra-
tions through prolonged use of gasoline pow-
ered hand tools could cause blood vessel or
nerve damage in the fingers, hands, and
joints of people prone to circulation disorders
or abnormal swelling. Prolonged use in cold
weather has been linked to blood vessel dam-
age in otherwise healthy people. If symptoms
occur such as numbness, pain, loss of
strength, change in skin color or texture, or
loss of feeling in the fingers, hands, or joints,
discontinue the use of this tool and seek
medical attention. An antivibration system
does not guarantee the avoidance of these
problems. Users who operate power tools on
a continual and regular basis must monitor
closely their physical condition and the condi-
tion of this tool.
D
D
D
D
To avoid spreading fire, do not use near
leaf or brush fires, fireplaces, barbecue
pits, ashtrays, etc.
Use only for jobs explained in this manual.
MAINTAIN YOUR UNIT PROPERLY
D Have all maintenance other than the rec-
ommended procedures described in the in-
struction manual performed by an autho-
rized service dealer.
D Disconnect spark plug before performing SPECIAL NOTICE: For users on U.S. For-
maintenance except for carburetor adjust-
ments.
est Land and in some states, including Cali-
fornia (Public Resources Codes 4442 and
4443), Idaho, Maine, Minnesota, New Jersey,
Oregon, and Washington: Certain internal
combustion engines operated on forest,
brush, and/or grass covered land in the above
areas are required to be equipped with a
spark arresting screen, maintained in effec-
tive working order, or the engine must be con-
structed, equipped, and maintained for the
prevention of fire. Check with your state or lo-
cal authorities for regulations pertaining to
these requirements. Failure to follow these
requirements is a violation of the law. This unit
is not factory equipped with a spark arresting
screen; however, a spark arresting screen is
available as an optional part. If a spark arrest-
ing screen is required in your area, contact
your authorized service dealer for the correct
kit. The spark arresting screen, blower tubes,
and nozzles must be assembled to unit to be
in full compliance with regulations.
D Use only recommended Poulan PRO re-
placement parts; use of any other parts
may void your warranty and cause damage
to your unit.
D Empty fuel tank before storing the unit. Use
up fuel left in carburetor by starting engine and
letting it run until it stops.
D Do not use any accessory or attachment
other than those recommended by manufac-
turer for use with your unit.
D Do not store the unit or fuel in a closed area
where fuel vapors can reach sparks or an
open flame from hot water heaters, electric
motors or switches, furnaces, etc.
D Store in a dry area out of reach of children.
ASSEMBLY
NOTE: Knob must be loose enough to allow
blower tube to be inserted in blower outlet.
ning counterclockwise.
WARNING: Stop engine and be sure
the impeller blades have stopped turning be-
fore opening the vacuum inlet door or at-
tempting to insert or remove the vacuum or
blower tubes. The rotating blades can cause
serious injury. Always disconnect the spark
plug before performing maintenance or ac-
cessing movable parts.
Blower
Blower
Outlet
Tube
Groove
Rib
WARNING: If you receive your unit
assembled, check each step to insure your
unit is properly assembled and all fasteners
are secure. Follow all safety information in
the manual and on the unit.
2. Secure the tube by turning the knob clock-
wise.
3. To remove the tube, turn the knob counter-
clockwise to loosen the tube; remove the
tube.
D
A standard screwdriver is required for as-
sembly.
VACUUM BAG ASSEMBLY
1. Open the zipper on the vacuum bag and
insert the elbow tube.
BLOWER TUBE ASSEMBLY
1. Align the rib on the blower tube with the
groove in the blower outlet; slide the tube 2. Push the small end of the elbow tube
into place.
through the small opening in the bag.
-- 3 --
Download from Www.Somanuals.com. All Manuals Search And Download.
Elbow
Tube
4. Hold the vacuum inlet cover open until up-
per vacuum tube is installed.
Small
Opening
Vacuum Inlet
Zipper
Opening
Rib
Retaining Post
NOTE: Make sure edge of the small opening
is flush against the flared area of the elbow
tube, and the rib on the elbow tube is on the
bottom.
Vacuum
Inlet
Cover
3. Close the zipper on the bag. Make sure the
5. Place the hooks on the upper vacuum tube
on the retaining posts of the unit.
6. Pivot the tube until it is secured to the
zipper is closed completely.
4. Remove blower tube from engine.
blower unit by the vacuum inlet latch.
Rib
PIVOT
Inlet Cover
Latch
Groove
5. Insert the elbow tube into the blower outlet.
Make sure elbow tube rib is aligned with
the blower outlet groove.
6. Turn knob clockwise to secure elbow tube.
Retaining
Hook
Post
VACUUM TUBE ASSEMBLY
WARNING: Stop engine and be sure
the impeller blades have stopped turning be-
fore opening the vacuum inlet door or at-
tempting to insert or remove the vacuum or
blower tubes. The rotating blades can cause
serious injury.
1. Align the lower vacuum tube as shown.
Push lower vacuum tube into upper vacu-
um tube.
HOW TO CONVERT UNIT FROM
VACUUM USE TO BLOWER USE
1. Remove the vacuum tubes by inserting
the tip of a screwdriver into the latch area
of the vacuum inlet.
2. Gently tilt handle of screwdriver toward
the back of the unit to release the latch
while pulling up on the upper vacuum tube
with your other hand.
Upper Vacuum
Tube
Latch Area
Lower Vacuum Tube
2. Insert the tip of a screwdriver into the latch
area of the vacuum inlet.
Blower
Outlet
Latch
Ar
Latch Area
Vacuum
Inlet Cover
3. Remove the vacuum bag.
4. Close the vacuum inlet cover and make
sure it is latched closed.
5. Reinstall the blower tube (see BLOWER
3. Gently tilt the handle of the screwdriver to-
ward the back of the unit to release the
latch while pulling up on the vacuum inlet
cover with your other hand.
TUBE ASSEMBLY).
-- 4 --
Download from Www.Somanuals.com. All Manuals Search And Download.
SHOULDER STRAP ADJUSTMENT
1. Hold the unit as shown with the muffler side
facing away from your body and clothes.
2. Pass the shoulder strap over your head
and onto your right shoulder.
3. Extend your left arm toward the rear of the
vacuum bag.
4. Adjust shoulder strap until the vacuum
bag/shoulder strap seam lies between
your thumb and index finger.
5. Make sure air flows freely from the elbow
tube into bag. If bag is kinked, the unit will
not operate properly.
OPERATION
KNOW YOUR BLOWER
READ THIS INSTRUCTION MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT.
Compare the illustrations with your unit to familiarize yourself with the location of the various controls
and adjustments. Save this manual for future reference.
Lower
Vacuum Tube
Primer Button
Choke Lever
Vacuum Bag
Fuel Mix
Throttle
Fill Cap
Lever
Starter
Rope
Spark Plug
Elbow Tube
Blower
Tube
Rear
Handle
THROTTLE LEVER
CHOKE LEVER
The CHOKE helps to supply fuel to the engine
The THROTTLE LEVER is used to select the
desired engine speed and to stop the engine. to aid in cold starting. Activate the choke by
moving the choke lever to the FULL CHOKE
position. After engine attempts to start, move the
choke lever to the HALF CHOKE position.
Once engine starts, move choke lever to the
RUN position.
Move the throttle lever to the
full speed operation. Move the throttle lever
to the position for idle speed. To stop the
engine, move the throttle lever to the STOP
position.
position for
PRIMER BUTTON
The PRIMER BUTTON removes air from the
carburetor and fuel lines and fills them with fuel.
This allows you to start the engine with fewer
pulls on the starter rope. Activate primer button
by pressing it and allowing it to return to its origi-
nal position.
-- 5 --
Download from Www.Somanuals.com. All Manuals Search And Download.
This engine is certified to operate on
unleaded gasoline. Before operation,
gasoline must be mixed with a good quality
synthetic 2-cycle air-cooled engine oil
designed to be mixed at a ratio of 40:1. Poulan
PRO brand synthetic oil is recommended.
Mix gasoline and oil at a ratio of 40:1. A 40:1
ratio is obtained by mixing 3.2 ounces (95 ml)
of oil with 1 gallon (4 liters) of unleaded
gasoline. DO NOT USE automotive oil or
boat oil. These oils will cause engine damage.
When mixing fuel, follow instructions printed
on container. Once oil is added to gasoline,
shake container momentarily to assure that
the fuel is thoroughly mixed. Always read and
follow the safety rules relating to fuel before
fueling your unit.
OPERATING POSITION
ye
otec
Blower
Vacuum
IMPORTANT
OPERATING TIPS
Experience indicates that alcohol blended
fuels (called gasohol or using ethanol or
methanol) can attract moisture which leads to
separation and formation of acids during
storage. Acidic gas can damage the fuel
system of an engine while in storage. To avoid
engine problems, empty the fuel system
before storage for 30 days or longer. Drain the
gas tank, start the engine and let it run until the
fuel lines and carburetor are empty. Use fresh
S While vacuuming or blowing debris, hold
the unit with the muffler side facing away
from your body and clothes (see OPERAT-
ING POSITION illustration above).
S To reduce the risk of hearing loss
associated with sound level(s), hearing
protection is required.
S To reduce the risk of injury associated with
contacting rotating parts, stop the engine be-
fore installing or removing attachments. Do
not operate without guard(s) in place.
S Operate power equipment only at reasonable
hours--not early in the morning or late at night
when people might be disturbed. Comply with
times listed in local ordinances. Usual recom-
mendations are 9:00 a.m. to 5:00 p.m.,
Monday though Saturday.
fuel next season.
Never use engine or
carburetor cleaner products in the fuel tank or
permanent damage may occur.
NOTE: Unit must be placed on its side when
adding fuel (see illustration below).
S To reduce noise levels, limit the number of
pieces of equipment used at any one time.
S To reduce noise levels, operate power
blowers at the lowest possible throttle
speed to do the job.
S Use rakes and brooms to loosen debris be-
fore blowing.
S In dusty conditions, slightly dampen sur-
faces or use a mister attachment when wa-
ter is available.
S Conserve water by using power blowers
instead of hoses for many lawn and garden
applications, including areas such as gutters,
screens, patios, grills, porches, and gardens.
S Watch out for children, pets, open windows,
or freshly washed cars. Blow debris away
safely.
S Use the full blower nozzle extension so the
air stream can work close to the ground.
S After using blowers and other equipment,
CLEAN UP! Dispose of debris in trash re-
ceptacles.
TO STOP THE ENGINE
D To stop the engine, move the throttle lever
to the STOP position.
BEFORE STARTING ENGINE
BEFORE STARTING THE ENGINE
WARNING: Be sure to read the fuel
information in the safety rules before you be-
gin. If you do not understand the safety rules,
do not attempt to fuel your unit. Call
1-800-554-6723 .
WARNING: You MUST make sure
the tubes are secure before using the unit.
D
Fuel engine. Move at least 10 feet (3 me-
ters) away from the fueling site.
Hold the unit in the starting position as
shown. Make sure the blower end is di-
rected away from people, animals, glass,
and solid objects.
FUELING ENGINE
D
WARNING: Remove fuel cap slowly
when refueling.
-- 6 --
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Pull starter rope sharply until engine at-
tempts to run, but no more than 5 pulls (be-
low 30_ F, 8 pulls).
STARTING POSITION
NOTE: If engine attempts to start before the
th
5
pull, go to next step immediately.
5. Move the choke lever to the HALF
CHOKE position.
6. Pull the starter rope sharply until the en-
gine runs, but no more than 5 pulls (below
30_ F, 10 pulls).
7. After a 5 second warm--up, move the
choke lever to the RUN position.
8. Allow the unit to run for 30 more seconds
at the RUN position before moving the
Blower
throttle lever to
position.
If engine has not started after 5 pulls (at HALF
CHOKE), repeat STARTING A COLD ENGINE
procedure. If engine still does not start, proceed
to STARTING A FLOODED ENGINE.
9. To stop the engine, move the throttle lever to
the STOP position.
STARTING A WARM ENGINE
NOTE: If fuel tank is empty, add fuel; then,
follow STARTING A COLD ENGINE proce-
dure. Do not fill fuel tank while engine is hot.
WARNING: When starting engine,
hold the unit as illustrated. Do not set unit on any
surface except a clean, hard area when starting
engine or while engine is running. Debris such
as gravel, sand, dust, grass, etc. could be
picked up by the air intake and thrown out
through the discharge opening, damaging the
unit or property, or causing serious injury to by-
standers or the operator.
1. Move throttle lever to the
position.
STARTING A COLD ENGINE
1. Move throttle lever to the
2. Pull starter rope sharply until engine runs,
position.
but no more than 5 pulls.
2. Move choke lever to the FULL CHOKE
position.
3. Slowly press the primer button 8 times.
NOTE: If engine has not started, pull starter
rope 5 more pulls. If engine still does not run,
it is probably flooded.
3. To stop the engine, move the throttle lever to
T
the STOP position.
STARTING A FLOODED ENGINE
Flooded engines can be started by placing the
choke lever in the RUN position. Move throttle
lever to the fast position
; then, pull rope
until engine starts. After engine starts, move the
throttle lever to the slow position
engine to idle.
to allow
Starting could require pulling the starter rope
many times depending on how badly the unit is
flooded.
If unit still doesn’t start refer to the TROUBLE-
SHOOTING TABLE or call 1-800-554-6723.
Choke Lever
MAINTENANCE
instructed in this manual. Various adjust-
ments will need to be made periodically to
properly maintain your unit.
WARNING: Avoid touching muffler
unless engine and muffler are cold. A hot
muffler can cause serious burns.
CHECK FOR LOOSE
FASTENERS AND PARTS
S Spark Plug Boot
S Air Filter
S Housing Screws
S Muffler
WARNING: Stop engine and be sure
the impeller blades have stopped turning be-
fore opening the vacuum inlet door or at-
tempting to insert or remove the vacuum or
blower tubes. The rotating blades can cause
serious injury. Always disconnect the spark
plug before performing maintenance or ac-
cessing movable parts.
CHECK FOR DAMAGED OR WORN
PARTS
Contact an authorized service dealer for re-
placement of damaged or worn parts.
GENERAL RECOMMENDATIONS
The warranty on this unit does not cover items S Fuel Tank -- Do not use unit if fuel tank shows
that have been subjected to operator abuse
or negligence. To receive full value from the S Vacuum Bag -- Do not use vacuum bag if it
warranty, the operator must maintain unit as is torn or damaged.
signs of damage or leaks.
-- 7 --
Download from Www.Somanuals.com. All Manuals Search And Download.
INSPECT AND CLEAN UNIT AND
DECALS
REPLACE FUEL FILTER
To replace fuel filter, drain unit by running it dry
of fuel, then remove fuel cap/retainer assem-
bly from tank. Pull filter from tank and remove
it from the fuel line. Install new fuel filter on fuel
line; reinstall parts.
S After each use, inspect complete unit for
loose or damaged parts. Clean the unit and
decals using a damp cloth with a mild deter-
gent.
S Wipe off unit with a clean dry cloth.
CLEAN AIR FILTER
Fuel Line
Fuel Filter
Air Filter
Cover
CHECK MUFFLER MOUNTING
SCREWS
Once each year, ensure muffler mounting
screws are secure and tightened properly to
prevent damage.
Screws
Air Filter
Cleaning the air filter:
Mounting
Screw
Holes
A dirty air filter decreases engine perform-
ance and increases fuel consumption and
harmful emissions. Always clean or replace
air filter after every 5 hours of operation or
yearly, whichever comes first.
Muffler Cover
1. Clean the cover and the area around it to
keep debris from falling into the carburetor
chamber when the cover is removed.
2. Remove parts as illustrated.
Screws
NOTE: Do not clean filter in gasoline or other
flammable solvent. Doing so can create a fire
hazard or produce harmful evaporative emis-
sions.
1. Loosen and remove the 2 screws from the
muffler cover.
2. Remove the muffler cover.
3. Tighten the 2 muffler mounting screws se-
curely.
4. Reinstall muffler cover and 2 screws.
Tighten securely.
3. Wash the filter in soap and water.
4. Allow filter to dry.
5. Apply a few drops of oil to the filter;
squeeze filter to distribute oil.
6. Replace parts.
REPLACE SPARK PLUG
Replace spark plug each year to ensure the
engine starts easier and runs better. Set
spark plug gap at 0.025 inch. Ignition timing is
fixed, nonadjustable.
CARBURETOR ADJUSTMENTS
There is no screw for idle adjustment on your
blower. The throttle lever is used to control
engine speed. The throttle lever can be
placed in one of four positions: STOP, IDLE
1. Twist, then pull off spark plug boot.
2. Remove spark plug from cylinder and dis-
card.
or
, FULL THROTTLE or
, and one
3. Replace with Champion RCJ-6Y spark
intermittent position. If your engine will not run
plug and tighten securely with a 3/4 inch properly or you require further assistance,
socket wrench.
contact an authorized service dealer or call
1--800--554--6723.
4. Reinstall the spark plug boot.
STORAGE
open flames from water heaters, electric
motors or switches, furnaces, etc.
S Store unit with all guards in place. Position
unit so that any sharp object cannot acci-
dentally cause injury.
WARNING: Perform the following
steps after each use:
S Allow engine to cool, and secure the unit
before storing or transporting.
S Store unit and fuel in a well ventilated area S Store unit and fuel well out of the reach of
where fuel vapors cannot reach sparks or
children.
-- 8 --
Download from Www.Somanuals.com. All Manuals Search And Download.
SEASONAL STORAGE
ENGINE
Prepare unit for storage at end of season or if
it will not be used for 30 days or more.
If your unit is to be stored for a period of time:
S Clean the entire unit before lengthy stor-
age.
S Remove spark plug and pour 1 teaspoon of
40:1, 2-cycle engine oil (air cooled) through
the spark plug opening. Slowly pull the
starter rope 8 to 10 times to distribute oil.
S Replace spark plug with new one of recom-
mended type and heat range.
S Store in a clean dry area.
S Lightly oil external metal surfaces.
FUEL SYSTEM
Under FUELING ENGINE in the OPERA-
TION section of this manual, see message la-
beled IMPORTANT regarding the use of ga-
sohol in your engine.
Fuel stabilizer is an acceptable alternative in
minimizing the formation of fuel gum deposits
during storage. Add stabilizer to gasoline in fuel
tank or fuel storage container. Follow the mix
instructions found on stabilizer container. Run
S Clean air filter.
S Check entire unit for loose screws, nuts,
and bolts. Replace any damaged, broken,
or worn parts.
S At the beginning of the next season, use
only fresh fuel having the proper gasoline to
oil ratio.
OTHER
S Do not store gasoline from one season to
another.
engine at least 5 minutes after adding stabilizer. S Replace your gasoline can if it starts to rust.
TROUBLESHOOTING TABLE
WARNING: Always stop unit and disconnect spark plug before performing any of the
recommended remedies below other than remedies that require operation of the unit.
TROUBLE
Engine will not
start.
CAUSE
1. Engine flooded.
REMEDY
1. See “Starting a Flooded Engine”
in Operation section.
2. Fill tank with correct fuel mixture.
3. Install new spark plug.
2. Fuel tank empty.
3. Spark plug not firing.
4. Fuel not reaching
carburetor.
4. Check for dirty fuel filter; replace.
Check for kinked or split fuel line;
repair or replace.
5. Contact an authorized service dealer.
5. Compression low.
1. Fuel not reaching
carburetor.
1. Check for dirty fuel filter; replace.
Check for kinked or split fuel line;
repair or replace.
Engine will not
idle properly.
2. Carburetor requires
adjustment.
3. Crankshaft seals worn.
4. Compression low.
2. Contact an authorized service dealer.
3. Contact an authorized service dealer
4. Contact an authorized service dealer.
1. Clean or replace air filter.
2. Check for dirty fuel filter; replace.
Check for kinked or split fuel line;
repair or replace.
1. Air filter dirty.
2. Fuel not reaching
carburetor.
Engine will not
accelerate,
lacks power, or
dies under a
load.
3. Clean or replace spark plug
and re-gap.
3. Spark plug fouled.
4. Contact an authorized service dealer.
4. Carburetor requires
adjustment.
5. Carbon build up.
6. Compression low.
5. Contact an authorized service dealer.
6. Contact an authorized service dealer.
1. Choke partially on.
1. Adjust choke.
Engine smokes
excessively.
2. Fuel mixture incorrect.
2. Empty fuel tank and refill with
correct fuel mixture.
3. Air filter dirty.
4. Carburetor requires
adjustment.
3. Clean or replace air filter.
4. Contact an authorized service dealer.
Engine runs hot.
1. See “Fueling Engine” in Operation
section.
1. Fuel mixture incorrect.
2. Replace with correct spark plug.
3. Contact an authorized service dealer.
2. Spark plug incorrect.
3. Carburetor requires
adjustment.
4. Contact an authorized service dealer.
4. Carbon build up.
-- 9 --
Download from Www.Somanuals.com. All Manuals Search And Download.
LIMITED WARRANTY
ELECTROLUX HOME PRODUCTS, INC.,
cover predelivery setup or normal adjustments
warrants to the original purchaser that each new explained in the instruction manual.
Poulan PRO brand gasoline tool or attach-
ment is free from defects in material and work-
manship and agrees to repair or replace under
this warranty any defective gasoline product or
attachment as follows from the original date of
purchase:
2 YEARS -- Parts and Labor, when used for
household purposes.
90 DAYS -- Parts and Labor, when used for
commercial, professional, or income producing
purposes.
30 DAYS -- Parts and Labor, if used for rental RANTY LASTS OR THE EXCLUSION OR
purposes.
This warranty is not transferable and does not
cover damage or liability caused by improper
handling, improper maintenance, or the use of
THIS WARRANTY GIVES YOU SPECIFIC
LEGAL RIGHTS, AND YOU MAY HAVE
OTHER RIGHTS WHICH VARY FROM
STATE TO STATE.
NO CLAIMS FOR CONSEQUENTIAL OR
OTHER DAMAGES WILL BE ALLOWED,
AND THERE ARE NO OTHER EXPRESS
WARRANTIES EXCEPT THOSE EX-
PRESSLY STIPULATED HEREIN.
SOME STATES DO NOT ALLOW LIMITA-
TIONS ON HOW LONG AN IMPLIED WAR-
LIMITATIONS OF INCIDENTAL OR CONSE-
QUENTIAL DAMAGES, SO THE ABOVE
LIMITATIONS OR EXCLUSION MAY NOT
APPLY TO YOU.
accessories and/or attachments not specifically The policy of ELECTROLUX HOME PRO-
recommended by ELECTROLUX HOME
DUCTS, INC., is to continuously improve its
PRODUCTS, INC., for this tool. Additionally, products. Therefore, ELECTROLUX HOME
this warranty does not cover tune-ups, spark
PRODUCTS, INC., reserves the right to
plugs, filters, starter ropes, starter springs, cut- change, modify, or discontinue models, de-
ting line, or rotating head parts that will wear and signs, specifications, and accessories of all
require replacement with reasonable use during products at any time without notice or obligation
the warranty period. This warranty does not to any purchaser.
U.S. EPA
EMISSION CONTROL WARRANTY STATEMENT
YOUR WARRANTY RIGHTS AND OB-
LIGATIONS: The U. S. Environmental
Protection Agency and ELECTROLUX
HOME PRODUCTS, INC., are pleased to ex-
plain the emissions control system warranty
solely for the lack of receipts or for your failure
to ensure the performance of all scheduled
maintenance. As the small off--road engine
owner, you should be aware that ELECTRO-
LUX HOME PRODUCTS, INC., may deny
on your year 2002--2004 small off--road en- you warranty coverage if your small off--road
gine. ELECTROLUX HOME PRODUCTS,
INC., must warrant the emission control sys-
engine or a part of it has failed due to abuse,
neglect, improper maintenance, unapproved
tem on your small off--road engine for the peri- modifications, or the use of parts not made or
ods of time listed below provided there has approved by the original equipment manufac-
been no abuse, neglect, or improper mainte- turer. You are responsible for presenting your
nance of your small off--road engine. Your small off--road engine to an ELECTROLUX
emission control system includes parts such
HOME PRODUCTS, INC., authorized repair
as the carburetor and the ignition system. center as soon as a problem exists. Warranty
Where a warrantable condition exists, ELEC- repairs should be completed in a reasonable
TROLUX HOME PRODUCTS, INC., will re-
pair your small off--road engine at no cost to have any questions regarding your warranty
you. Expenses covered under warranty in- rights and responsibilities, you should contact
clude diagnosis, parts and labor. MANUFAC- your nearest authorized service center or call
TURER’S WARRANTY COVERAGE: If any
ELECTROLUX HOME PRODUCTS, INC., at
emissions related part on your engine (as 1--800--554--6723.
WARRANTY COM-
listed under Emissions Control Warranty
MENCEMENT DATE: The warranty period
amount of time, not to exceed 30 days. If you
Parts List) is defective or a defect in the mate- begins on the date the small off--road engine
rials or workmanship of the engine causes the is purchased. LENGTH OF COVERAGE:
failure of such an emission related part, the This warranty shall be for a period of two
part will be repaired or replaced by ELEC-
TROLUX HOME PRODUCTS, INC. OWN-
ER’S WARRANTY RESPONSIBILITIES:
years from the initial date of purchase. WHAT
IS COVERED: REPAIR OR REPLACE-
MENT OF PARTS. Repair or replacement of
As the small off--road engine owner, you are any warranted part will be performed at no
responsible for the performance of the re- charge to the owner at an approved ELEC-
quired maintenance listed in your instruction TROLUX HOME PRODUCTS, INC., servic-
manual. ELECTROLUX HOME PROD-
ing center. If you have any questions regard-
UCTS, INC., recommends that you retain all ing your warranty rights and responsibilities,
receipts covering maintenance on your small you should contact your nearest authorized
off--road engine, but ELECTROLUX HOME
PRODUCTS, INC., cannot deny warranty
service center or call ELECTROLUX HOME
PRODUCTS, INC., at 1--800--554--6723.
-- 1 0 --
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY PERIOD: Any warranted part
which is not scheduled for replacement as re- caused by the use of add--on or modified
quired maintenance, or which is scheduled parts. HOW TO FILE A CLAIM: If you have
only for regular inspection to the effect of “re- any questions regarding your warranty rights
not liable to cover failures of warranted parts
pair or replace as necessary” shall be war-
ranted for 2 years. Any warranted part which
is scheduled for replacement as required
and responsibilities, you should contact your
nearest authorized service center or call
ELECTROLUX HOME PRODUCTS, INC., at
maintenance shall be warranted for the period 1--800--554--6723. WHERE TO GET WAR-
of time up to the first scheduled replacement RANTY SERVICE: Warranty services or re-
point for that part. DIAGNOSIS: The owner
pairs shall be provided at all ELECTROLUX
shall not be charged for diagnostic labor HOME PRODUCTS, INC., service centers.
which leads to the determination that a war- Call 1--800--554--6723. MAINTENANCE,
ranted part is defective if the diagnostic work REPLACEMENT AND REPAIR OF EMIS-
is performed at an approved ELECTROLUX
HOME PRODUCTS, INC., servicing center.
CONSEQUENTIAL DAMAGES: ELEC-
TROLUX HOME PRODUCTS, INC., may be
SION RELATED PARTS: Any ELECTRO-
LUX HOME PRODUCTS, INC., approved re-
placement part used in the performance of
any warranty maintenance or repair on emis-
liable for damages to other engine compo- sion related parts will be provided without
nents caused by the failure of a warranted
part still under warranty. WHAT IS NOT
COVERED: All failures caused by abuse, ne-
charge to the owner if the part is under war-
ranty. EMISSION CONTROL WARRANTY
PARTS LIST: Carburetor, Ignition System:
glect, or improper maintenance are not cov- Spark Plug (covered up to maintenance
ered. ADD--ON OR MODIFIED PARTS: The schedule), Ignition Module. MAINTENANCE
use of add--on or modified parts can be STATEMENT: The owner is responsible for
grounds for disallowing a warranty claim.
ELECTROLUX HOME PRODUCTS, INC., is
the performance of all required maintenance
as defined in the instruction manual.
This engine is certified to be emissions compliant for the following use:
Moderate (50 hours)
Intermediate (125 hours)
Extended (300 hours)
-- 11 --
Download from Www.Somanuals.com. All Manuals Search And Download.
|