Chapter 1—Introduction  
About Your Meter........................................................................1-2  
About this Book...........................................................................1-3  
The Quick Reference Guide ...................................................... 1-4  
Specifications..............................................................................1-4  
Equipment.............................................................................1-4  
Material.................................................................................1-4  
Meter Settings.......................................................................1-5  
Glossary......................................................................................1-5  
Safety Notes ...............................................................................1-7  
Chapter 2—Getting Acquainted  
The B700/B702...........................................................................2-2  
Controls, Indicators and Machine Features, Front................ 2-2  
Controls, Indicators and Machine Features, Rear ................ 2-3  
B700/B702 Keypad (User Mode)................................................ 2-4  
Keypad Template (Setup Mode) ........................................... 2-6  
Chapter 3—Using the Meter  
Turning the Meter On.................................................................. 3-2  
Before You Apply Power ....................................................... 3-2  
Applying Power.....................................................................3-2  
Warning Prompts .................................................................. 3-2  
Adjusting the Stacker.................................................................. 3-3  
Checking Postage Funds Available ............................................ 3-3  
Checking the Date ......................................................................3-3  
Advancing the Date .................................................................... 3-3  
Omitting the Date........................................................................3-4  
Selecting an Ad Slogan .............................................................. 3-4  
Selecting an Inscription (B700 Only) .......................................... 3-5  
Selecting an Account (B700 Only).............................................. 3-5  
SV60941 Rev. B  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Checking and Clearing the Batch Register................................. 3-6  
Standard Operation (B702 and B700 With No  
Accounting)...........................................................................3-6  
Printing a Register Report .......................................................... 3-7  
Printing a Register Report (B702 and B700 With or  
Without Accounting).............................................................. 3-7  
Printing Account Reports (B700 Only)........................................ 3-8  
If You Have Departmental Accounting .................................. 3-8  
Printing an Account Report................................................... 3-8  
Printing Postage Using the Default Value................................... 3-9  
Changing the Postage Value .................................................... 3-10  
Printing Postage Using the Memory Keys (B700 Only) ........... 3-11  
Chapter 4—Setting Up the Meter  
Using the Keyboard Setup Template .......................................... 4-3  
Entering Setup............................................................................4-3  
Entering Alpha Characters.................................................... 4-3  
Entering Numeric Characters ............................................... 4-3  
Navigating the Menus................................................................. 4-4  
Setting Up Options......................................................................4-4  
Menu 1: Change Language....................................................... 4-7  
Menus 3, 4, 5 and 6: Set Memory Keys (B700 Only) ................ 4-7  
Menu 7: Set Daylight Saving Time............................................. 4-9  
Menu 8: Select Default Advertisement....................................... 4-9  
Menu 9: Set Default Inscription (B700 Only) ........................... 4-10  
Menu 10: Set Account Default (B700 Only)............................. 4-10  
Menu 11: Set Low Funds Warning........................................... 4-11  
Menu 12: Set Postage Default Value....................................... 4-12  
Menu 13: Set Timeout Length ................................................. 4-13  
Menu 14: Activate Features (B700 Only)................................. 4-14  
Menu 15: Print Setup Report (B700 Only)............................... 4-15  
Menu 16: Print Account Report (B700 Only) ........................... 4-16  
iv  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Menu 17: Clear All Accounts (B700 Only)................................ 4-17  
Menu 18: Move Clock Ahead................................................... 4-18  
Menu 19: Move Clock Back..................................................... 4-18  
Menu 20: Create Account (B700 Only).................................... 4-19  
Menu 21: Delete Account (B700 Only) .................................... 4-20  
Menu 22: Change Account Names (B700 Only)...................... 4-21  
Menu 23: Change Supervisor Password (B700 Only)............. 4-22  
Menu 24: Enable Password (B700 Only) ................................ 4-22  
Menu 25: Enable Accounting (B700 Only)............................... 4-23  
Menu 26: Set Time of Date Change ........................................ 4-24  
Menu 27: Set the Default Refill Amount................................... 4-25  
Menu 28: Set Printer Connection (B700 Only) ........................ 4-25  
Menu 29: Set Up EIU (DataLink) (B700 Only)......................... 4-26  
Chapter 5—Refilling the Meter  
Obtaining the Current Meter Access Code ................................. 5-2  
Obtaining the Refill Combination ................................................ 5-3  
Refilling Your Meter on the Internet ...................................... 5-3  
Refilling Your Meter on the Phone ........................................ 5-4  
Entering Your Refill Amount into the Meter................................. 5-5  
Payment Options ........................................................................5-5  
Purchase Power ................................................................... 5-5  
Reserve Account................................................................... 5-6  
United States Postal Service ................................................ 5-8  
Performing an Inspection on Your Meter .................................. 5-10  
Obtaining the Current Meter Access Code ......................... 5-10  
Performing the Inspection................................................... 5-11  
Entering Your Combination in the Meter............................. 5-11  
Chapter 6—Replacing the Ribbon  
Removing the Used Ribbon Cassette......................................... 6-2  
Installing the New Cassette ........................................................ 6-4  
SV60941 Rev. B  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Chapter 7—Troubleshooting  
Error and Warning Messages..................................................... 7-2  
Fault Messages ..........................................................................7-2  
If You Need Service .................................................................... 7-2  
Chapter 8—Supplies and Options  
Advertising Slogan Cartridge...................................................... 8-2  
Using the Slogan Cartridge................................................... 8-2  
Moistener (B700 Only) ............................................................... 8-3  
Attaching the Moistener........................................................ 8-3  
Filling Moistener.................................................................... 8-4  
Using the Moistener.............................................................. 8-4  
Bypassing the Moistener ...................................................... 8-5  
Maintaining the Moistener..................................................... 8-5  
DataLink (Electronic Interface Unit) (B700 Only) ....................... 8-6  
Ordering Supplies and Options................................................... 8-6  
Appendix A  
Meter Inscriptions .......................................................................A-2  
vi  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1 • Introduction  
This chapter lists the key features of your postage  
meter, tells you what's in this book, and presents  
important safety information.  
About Your Meter..............................................1-2  
About this Book ................................................1-3  
The Quick Reference Guide.............................1-4  
Specifications ...................................................1-4  
Glossary ...........................................................1-5  
Safety Notes.....................................................1-7  
SV60941 Rev. B  
1-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1 • Introduction  
The B700/B702 is a compact, programmable postage meter  
that combines simplicity of operation with user-changeable  
features that let you tailor its operation to your own unique  
requirements. The meter is supplied pre-programmed, so  
you can start processing mail right away using its factory set-  
tings. You can change some of these settings at the push of  
a button; or, if you wish, you can easily program the meter  
with your own settings.  
About Your Meter  
The meter's advanced features include:  
Sleek, compact design  
An easy-to-use, multi-purpose keypad  
11-character operator display  
Self-prompting setup menus  
Automatic date advance  
Daily piece count printing  
Keyboard-selectable ads  
Keyboard-selectable inscriptions (B700 only)  
Easy addition of advertising slogans by means of a re-  
movable slogan cartridge  
Easy addition of inscriptions via download (B700 only)  
Easy, convenient funds refill via Postage By Phone®  
Digital printing technology eliminates dies, ink rollers and  
ink  
Sharp 8 dot/mm printing resolution for clear, crisp meter  
imprints  
Optional accounting feature tracks postage spent by de-  
partment name. This feature supports up to 10 accounts  
(B700 only).  
Password protection provides an added measure of se-  
curity by limiting access to key meter functions to autho-  
rized personnel  
Communications port for an optional Pitney Bowes elec-  
tronic scale or other peripheral devices (B700 only)  
1-2  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction • 1  
Report printing: the meter generates and prints a register  
summary, setup summary, and Postage By Phone® sum-  
mary. The B700 also generates and prints a setup sum-  
mary.  
The Introduction lists the important features of your meter,  
provides material and equipment specifications and a brief  
glossary of terms. It also includes important notes about us-  
ing your meter safely.  
About this Book  
Getting Acquainted explains the purpose and shows the lo-  
cation of each control and machine feature. Please read this  
section carefully. It provides a foundation for the instructions  
given in later sections of this book.  
Using the Meter explains how to process mail. The opera-  
tions covered here are the ones you'll use most often.  
Setting Up the Meter provides step-by-step instructions for  
customizing meter operation to suit your own needs.  
Refilling the Meter explains how to add postage funds to  
your meter using Pitney Bowes' convenient Postage By  
Phone® service.  
Replacing the Ribbon provides instructions for removing  
and replacing the ribbon cassette.  
Troubleshooting explains the error and warning messages  
that might appear on the meter's display during the course of  
operation.  
Options/Supplies describes the optional ad slogan cartridge  
and explains how to use it. In addition, optional equipment  
specific to the B700 model is featured. Items include a moist-  
ener to assist envelope sealing and Datalink (Electronic In-  
terface KUnit or EIU) that expands account capacity from 10  
to 100 accounts and connects the meter to external devices  
such as a Pitney Bowes electronic scale, modem, serial  
printer or personal computer.  
This chapter also lists the supplies available for your meter  
and explains how to order them.  
SV60941 Rev. B  
1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1 • Introduction  
Don't like reading  
manuals? Try the  
Quick Reference  
Guide supplied with  
The Quick  
Reference Guide  
your meter. It's lo-  
cated in the ribbon  
compartment just  
above the cassette.  
It contains condensed  
instructions for most of the topics covered in this book.  
Equipment  
Specifications  
Size: 11.75"L x 9.75"W x 7"H in. (30 cm x 25 cm x 18 cm)  
Weight: 17.6 lbs. (8 kg), approximate  
Power Requirements: 120 VAC, 60 Hz, 3A  
Operating Temperature: 40°F (4°C) to 109°F (43°C)  
Average Throughput: 30 envelopes per minute maximum.  
Actual throughput will vary, depending on the material used  
and the skill of the operator.  
Ribbon Life: 1,200 impressions maximum; this will vary, de-  
pending on the number of ads printed.  
Material  
Minimum Size: 3" x 3" (76 mm x 76 mm)  
Maximum Size: 10" x 13.5" (250 x 340 mm)  
Minimum Thickness: 0.007" (0.2 mm)  
Maximum Thickness: .24 in. (6 mm)  
IMPORTANT! For best results, make sure that your material  
(envelopes, postcards) conforms fully to these specifications. We  
do not recommend textured or rough-surfaced papers because  
they may cause poor print quality. Mail that presents an uneven  
surface to the print mechanism may also cause poor print qual-  
ity. (Tapping mail contents to the top right envelope corner may  
help.) Use tape sheets to apply postage to rough surfaced or  
oversize mailpieces.  
1-4  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction • 1  
Meter Settings  
Maximum Imprint: $99.999 (B700) or $9.999 (B702)  
Reset Type: Postage By Phone®  
Piece Count: Up to 8 digits (non-resettable)  
Postage Used Register: 10 digits  
Postage Unused Register: 8 digits  
Meter  
Serial  
Number  
Date  
Ad  
Slogan  
Postal  
Inscription Office  
Use  
For Post  
City, State  
Origin  
ZIP  
Code  
Typical Indicia  
Some of the words used in this manual may be new to you.  
This little glossary explains what they mean.  
Glossary  
Account  
A department or other entity to which post-  
(B700 Only) age is charged. The B700 meter allows you  
to select from up to 10 accounts. You may  
identify accounts by a unique name when  
you set your meter up. Accounting is an  
optional feature on the B700.  
Ascending  
Register  
($ Used)  
The total amount of postage used since the  
meter was placed in service.  
SV60941 Rev. B  
1-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1 • Introduction  
Glossary  
(continued)  
Batch  
Register  
A part of the meter's memory that stores  
the total postage spent and the number of  
mailpieces processed. If your meter has  
the optional departmental accounting fea-  
ture, it stores this data in memory for each  
account. You can clear the contents of the  
batch register if you want.  
Default  
A value or setting the meter automatically  
returns to after a set period of time. As de-  
livered, your meter has factory-set defaults.  
You may change these if you wish.  
Descending The postage funds available for use. The  
Register imprint produced by the postage meter as  
($ Available) shown in the figure on page 1-5. The word  
“indicia” means “postal markings.” The  
markings may include:  
An Ad Slogan: This is an optional part of  
the indicia that lets you convey your own  
special message to the mail recipient. You  
may choose from a great variety of stan-  
dard and custom ads available from the PB  
Supply Line. Ads are supplied in a plug-in  
slogan cartridge. (See Chapter 8).  
A Postal Inscription: (B700 only) This in-  
formation appears next to the indicia or ad  
slogan and complies with postal regulations  
concerning the class of delivery or service.  
An endorsement is similar to an inscription,  
but appears in the area normally reserved  
for the ad slogan because of space require-  
ments. Inscriptions are available from the  
PB Supply Line(See Chapter 8).  
The Date  
The City/State  
The Meter's Serial Number  
Origin ZIP Code  
Information for Post Office Use  
1-6  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction • 1  
Refill  
The process of adding postage funds to  
your meter using the Pitney Bowes Post-  
age By Phone® Service. Sometimes called  
“resetting” the meter.  
Setup  
The process of customizing the meter to  
best suit your own needs.  
Timeout  
A period of time, measured from the last  
key press or meter trip, after which the me-  
ter automatically returns to its default set-  
tings. You can set timeout length when you  
set the meter up.  
Trip  
The process of dispensing and account-  
ing for postage. The meter is said to “trip”  
when it senses the envelope and starts  
printing.  
Please follow these common-sense precautions whenever  
you use your meter:  
Safety Notes  
Plug the meter into a properly grounded wall outlet. This  
reduces the risk of shock and equipment damage in  
the event of a short circuit. DO NOT remove the power  
cord's ground pin and DO NOT use a ground adapter.  
The power cord wall plug is the primary means of dis-  
connecting the meter from the AC supply. The meter is  
on whenever it is plugged into a live receptacle, even  
though the key switch and operator display may be off.  
Place the meter close to an easily accessible wall outlet.  
Avoid using wall outlets controlled by wall switches or  
shared by other equipment.  
Make sure the area in front of the wall outlet into which  
the meter is plugged is free from obstruction.  
DO NOT route the power cord over sharp edges or trap it  
between pieces of furniture. Make sure there is no strain  
on the power cord.  
SV60941 Rev. B  
1-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1 • Introduction  
To reduce the risk of fire or electrical shock, DO NOT  
attempt to remove covers or disassemble the meter.  
The cabinet encloses hazardous parts. If the meter was  
dropped or otherwise damaged, report such damage to  
your Pitney Bowes Customer Service Representative.  
Safety Notes  
(continued)  
Keep fingers, long hair, jewelry and loose clothing away  
from moving parts at all times.  
Read all instructions before you attempt to operate the  
meter.  
Use the equipment only for its intended purpose.  
Printhead temperature can reach 103° F (43° C), making  
it warm to the touch.  
Always follow the specific occupational safety and health  
standards prescribed for your workplace.  
Switch the meter OFF when you change the ribbon cas-  
sette.  
1-8  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 • Getting Acquainted  
This chapter lists the controls, indicators and ma-  
chine features of your meter.  
The B700/B702 ................................................2-2  
Controls, Indicators and  
Machine Features, Front View....................2-2  
Controls, Indicators and  
Machine Features, Rear View ....................2-3  
B700/B702 Keypad (User Mode) .....................2-4  
Keypad Template (Setup Mode).................2-6  
SV60941 Rev. B  
2-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 • Getting Acquainted  
The B700/B702  
Controls, Indicators and Machine Features, Front View  
5
6
4
3
7
2
8
9
1
1. Moistener (Optional)—Moistens and helps to seal an envelope as you guide it  
onto the meter. (B700 only)  
2. Feed Deck—Supports your envelope, post card or tape sheet as it passes  
through the indicia printer. Place your envelope or tape sheet face up on this  
deck. Push it up against the rear wall to align it and move it to the right, up to the  
trip mark (item 9).  
3. Rear Wall—Serves as an alignment guide for your envelope.  
4. Access Door—The ribbon cassette and Quick Reference Guide are behind this  
door. Open the door from the right.  
5. Ad Slogan Cartridge Well—The optional ad slogan cartridge goes here.  
6. Operator Display—This 11-character display shows the current status of the  
meter, normally displaying the default postage value. You can choose to display  
the postage used and postage available, the date and the ad. The B700 dis-  
plays the current account and inscription as well. The display also prompts you  
through the entire setup routine.  
7. Keypad—Enter your postage amount or commands here. See pages 2-3 and 2-  
4 for a description of each button's function.  
2-2  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Getting Acquainted • 2  
8. Stacker—Completed mailpieces are stacked here.  
9. Trip Mark—When feeding an envelope, make sure you guide it up against the  
rear wall (item 3). Then guide it to the right until its lead edge touches this mark;  
the meter senses the envelope, prints the postage amount and conveys the  
piece into the stacker.  
Controls, Indicators and Machine Features, Rear View  
1. Ad Slogan Car-  
1
tridge Well—Ad-  
ditional ads (and  
inscriptions for  
4
5
B700) are available  
by plugging the  
2
optional ad slogan  
cartridge in here.  
2. Lock—Prevents  
unauthorized use of  
your meter. Insert  
the key and turn it  
to the right to unlock  
the meter. Always  
keep the key in a  
safe place. The me-  
ter has no ON/OFF  
switch.  
3
3. Power Cord Connector—Connect the power cord here and plug the other end  
into a 120 VAC, 60 Hz grounded wall outlet.  
WARNING! Don't use an ungrounded outlet or a ground adapter. Adapters  
may not ground the equipment properly. In the event of a short circuit, a  
faulty ground could damage the meter and result in a possible shock hazard  
to the user.  
4 . Security Door—The USPS Seal is located here. The door is for use by Postal  
only. (Some meters may not have a security door.)  
5. Communications Port—Allows your meter to communicate with a Pitney Bowes  
electronic scale or other devices. (Not active in the B702)  
SV60941 Rev. B  
2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 • Getting Acquainted  
B700/B702 Keypad (User Mode)  
B700 Only  
Your meter has two modes of operation: user, for routine, day-to-day operations; and  
setup, which lets you customize the meter to suit your own needs. The keyboard  
functions differently, depending on which mode you're in.  
In the User Mode, the keys function as follows  
Account (B700 Only)—Accounting is an optional feature) Press to see the cur-  
rent account number or change accounts.  
Value/Pieces—Displays the contents of the batch register, that is, the total post-  
age spent since the batch register was last cleared. Press this button again to  
see the total number of mailpieces (batch count) processed.  
If your B700 is equipped with the optional accounting feature, you can view the  
total postage applied to and the number of pieces processed for any account.  
2-4  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Getting Acquainted • 2  
+ Date—Press to see the date that will be printed as a part of the meter imprint.  
This is usually the current date. You can also advance the date up to a maximum  
of 30 days from the current date.  
Date On/Off—Allows you to print the date, omit the date or omit (“duck”) the day.  
Ad—Press to see the name of the ad that will print when the meter is tripped.  
Press the key repeatedly to select different ads.  
Inscription (B700 only)—Press to see the current inscription or change the in-  
scription.  
Memory Keys 1, 2 , 3 and 4 (B700 only)—Press to select a pre-programmed  
meter configuration. A “configuration” specifies a postage amount, ad slogan  
number and inscription number. You program the memory keys using the B700's  
setup menus.  
Numeric Keys (0-9)—Use these to enter a numeric value for a postage amount  
or to select a particular menu choice.  
Clear (C)—Press to clear an entry. You may also use this key along with the  
Value/Pieces key to reset the batch count registers to zero.  
Decimal (.)—Press to enter a decimal point. You have the option of entering the  
decimal point manually or letting the meter enter it for you. You must always type  
a decimal point first when you enter a fractional value such as 15.8¢ (enter this  
value as .158).  
$ Available—Press to display the total amount of postage funds remaining.  
$ Used—Press to display the total amount of postage the meter has dispensed  
since it was placed in service.  
Refill—Press to begin the process of refilling the meter using the Pitney Bowes  
Postage By Phone® service.  
Enter—Press to accept a selection.  
SV60941 Rev. B  
2-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 • Getting Acquainted  
Keypad Template (Setup Mode)  
Backspace  
Space  
Use the Setup Mode to tailor meter operation to your own exact needs. To get into  
the Setup Mode, place the keypad template on the keypad as shown (below, right).  
You'll find the template in a pocket on the inside rear cover of this book. Press the  
C (Clear) and Enter keys at the same time. (B700 only-If your meter's password  
feature is on, the display will ask you to enter your password. See Chapter 4 for com-  
plete instructions.)  
In the Setup Mode the keys function as  
follows:  
Backspace (  
rightmost character displayed.  
)—Press to erase the  
Space (  
characters.  
)—Press for a space between  
Yes—Press to accept the setup menu  
choice.  
No—Press to reject the setup menu  
choice.  
Place Template on Keypad (Store  
template in pocket located on the  
inside rear cover for future use)  
2-6  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Getting Acquainted • 2  
Green, Red, Blue—Use to enter alpha characters (letters). Press the appropriate  
color and numeric keys at the same time to get an alpha character. For example:  
-
-
-
Green and 1 for A;  
Red and 8 for W;  
Blue and 5 for O.  
Exit Setup—Press to leave the setup mode.  
Clear—Press to remove an entry.  
Enter—Press to accept an entry.  
SV60941 Rev. B  
2-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 • Using the Meter  
This chapter explains how to use your postage  
meter.  
Turning the Meter On .......................................3-2  
Adjusting the Stacker .......................................3-3  
Checking Postage Funds Available..................3-3  
Checking the Date............................................3-3  
Advancing the Date..........................................3-3  
Omitting the Date .............................................3-4  
Selecting an Ad Slogan ....................................3-4  
Selecting an Inscription (B700 Only)................3-5  
Selecting an Account (B700 Only)....................3-5  
Checking and Clearing the Batch Register ......3-6  
Printing a Register Report................................3-7  
Printing Account Reports (B700 Only)..............3-8  
Printing Postage Using the Default Value.........3-9  
Changing the Postage Value..........................3-10  
Printing Postage Using the Memory  
Keys (B700 Only) ...........................................3-11  
SV60941 Rev. B  
3-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 • Using the Meter  
Before You Apply Power  
Turning the  
Meter On  
Make sure the meter is plugged into a properly grounded  
receptacle.  
If your're using an optional advertising slogan cartridge,  
make sure it's in place (Chapter 8).  
Check that the stacker is in position (see instructions be-  
low).  
Make sure the ribbon cassette is properly loaded (Chap-  
ter 6).  
If you’re using a Pitney Bowes electronic scale with your  
meter, make sure it’s connected properly. Follow the in-  
structions supplied with the scale. (B700 only)  
Add E-Z Seal® to the optional moistener if necessary.  
Follow the instructions supplied with your moistener.  
(B700 only)  
The instructions that follow assume the meter is set up the  
way you want. If not, go to Chapter 4 for step-by-step setup  
instructions.  
Applying Power  
Insert the key and turn it  
clockwise. After you turn it on,  
the meter performs a self test  
for several seconds and oper-  
ates the envelope transport  
mechanism.  
If the self test is OK, the meter  
shows the default postage  
value in the operator display  
as shown at the right (your de-  
fault value may be different).  
Warning Prompts  
HINT: If postage funds  
are low, it's a good  
idea to refill your me-  
ter. See Chapter 5 for  
instructions.  
If postage funds are low, the operator display flashes “Low  
Funds” or “Insuf Funds” alternately with the postage value  
selected. If any other message appears on the display, see  
pages 7-2 and 7-3 of this guide for an explanation.  
3-2  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using the Meter • 3  
Slide the stacker into posi-  
tion up against the meter  
as shown. This position is  
good for envelopes up to  
#10. If you're running lon-  
ger envelopes, move the  
stacker to the right as nec-  
essary to accommodate  
them.  
Adjusting the  
Stacker  
1. Press $ Available to display the postage funds on hand.  
Checking  
Postage Funds  
Available  
2. Press $ Used to display the amount of postage already  
used.  
3. Press C (Clear) to return to the default postage display.  
Press +Date to check the date. The display shows the date  
exactly as it will be printed. Any omitted parts of the date ap-  
pear as dashes. (See Omitting the Date below.)  
Checking the  
Date  
1. To advance the date, press the +Date key again. This  
advances the date by one day. Each time you press the  
+Date key, the date advances by one more day. You can  
advance the date of submission up to 30 days. If you  
attempt to advance the date more than this, the meter  
prompts: “30 Days Max” after you press Enter and re-  
turns to the current date setting.  
Advancing the  
Date  
You can also advance the date by keying in a num-  
ber—from 1 to 30—and pressing Enter while the meter  
is in the date setting mode. For example, if you press 6  
and Enter, the date advances by six days and the display  
returns to the postage amount .  
2. To return to the current date, press the C key while the  
meter is in the date mode and press Enter. The display  
returns to the postage amount.  
SV60941 Rev. B  
3-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 • Using the Meter  
1. Press the Date On/Off key to see the current selection:  
“Date On;” Date Off;” or “No Day.” Pressing the Date On/  
Off key toggles (switches) among these three selections:  
Omitting the  
Date  
“Date On” means the complete date is printed as part  
of the indicia.  
“Date Off” means the date is not printed.  
“No Day” means the month and year are printed, but  
not the day.  
2. Select one of the three choices. Press Enter to confirm  
your selection.  
3. When you press +Date, the display shows the date ex-  
actly as it will print. Any omitted parts of the date appear  
as dashes.  
1. Press Ad to see the current ad selection. The display  
shows the name of the ad slogan. “NONE” means no ad  
slogan is selected.  
Selecting an Ad  
Slogan  
2. To change the selection, press the Ad key repeatedly  
until you see the name of the ad slogan you want. Press  
Enter to accept the slogan. The display then returns to  
the postage amount.  
Shortcut: When the meter is in the ad mode you can  
choose an ad slogan by typing its number on the numeric  
keypad and pressing Enter. You'll find the ad number  
on the slogan cartridge label. If the ad isn't available, the  
meter displays “No Ad.”  
HINT: Ad slogans are  
optional. See Chapter  
8 for details. When  
you select a slogan, it  
may take a little time to  
load. This is normal.  
NOTE: The ad you want may be in an ad slogan cartridge you  
haven’t loaded. See Chapter 8 for loading instructions. Press C  
(Clear) to return to the default postage display without changing  
the ad or to clear an error.  
3-4  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using the Meter • 3  
1. Press the Inscription key to see the name of the current  
inscription. If the display shows “NONE,” no inscription is  
selected.  
Selecting an  
Inscription  
(B700 Only)  
2. To change the inscription, press the Inscription key  
repeatedly until you see the name of the inscription you  
want. Press Enter to accept the inscription. The display  
then returns to the postage amount.  
HINT: Inscriptions are  
optional. If no inscrip-  
tions are enabled, the  
meter will prompt “No  
Inscrpts” when you  
press the Inscription  
key.  
Shortcut: When the meter is in the inscription mode you  
can choose an inscription by pressing its number on the  
keypad and pressing Enter. If you enter a wrong number,  
the meter displays “No Inscript.”  
Press C (Clear) at any time to return to the default post-  
age display without changing the inscription or to clear  
an error.  
1. Press Account to display the name of the current ac-  
count.  
Selecting an  
Account  
2. If you want to change the account to which postage is  
charged, press the Account key repeatedly until you  
see the account name you want. Press Enter to accept  
the account. The display will return to the default post-  
age amount and show the account ID number. (If the  
account is password protected, the meter prompts you to  
enter a password. Type in the password—up to four dig-  
its—and press Enter.)  
(B700 Only)  
Shortcut: When the meter is in the account mode (that is,  
displaying an account), you can choose an account by  
pressing its number on the keypad and pressing Enter.  
If you select a number the meter doesn’t recognize, the  
meter displays the message “No Accnt.”  
Press $ Avail then Enter at any time during the process  
to go back to the default postage display without chang-  
ing the account.  
HINT: Departmen-  
tal accounting is an  
optional feature. If your  
meter is not equipped  
with it, the display  
prompts “Accounting  
Disabled” when you  
press the Account key.  
SV60941 Rev. B  
3-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 • Using the Meter  
The meter's batch register stores the total postage value  
Checking and  
Clearing the  
Batch Register  
expended and the number of mail pieces processed since it  
waslast cleared. You can display this information and clear  
it—return the register to zero—if you want. The procedure for  
doing so depends on whether your meter is equipped with  
the optional departmental accounting feature.  
Standard Operation (B702 and B700 With No  
Accounting)  
1. Press the Value/Pieces key once. The display shows the  
total postage ($) spent.  
2. Press the Value/Pieces key again to see the total num-  
ber of mail pieces processed.  
3. To clear the batch register (return it to zero), press the  
Value/Pieces key and, while holding it, press C. The dis-  
play prompts “Cleared.”  
CAUTION! Be sure you really want to clear the  
register. Once you've done so, you can't restore its  
contents. If you want a record of the batch reg-  
ister before you clear it, print a register report as  
explained on the next page.  
3-6  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using the Meter • 3  
Printing a Register Report (B702 and B700 With or  
Without Accounting)  
1. Press the $ Available key. The display shows the post-  
Printing a  
Register Report  
age amount currently available.  
2. Place a spare envelope or index card on the deck, as  
though you were about to print postage. Guide the enve-  
lope up against the rear wall and slide it to the right until  
its lead edge is aligned with the trip mark on the deck.  
(See the figure in Printing Postage Using the Default  
Value.)  
3. The display prompts: “Reg Report Press Enter.”  
4. Press Enter; the meter prompts “Printing...”  
5. The meter will print a register report like that shown be-  
low. When printing is done, press Enter to return to the  
postage value display and resume processing mail.  
AAA PB2000002  
05:18P  
REGISTER REPORT  
MAR 17 95  
$14.878  
$99985.122  
$100000.000  
19  
ASCENDING REGISTER  
DESCENDING REGISTER  
CONTROL SUM  
METER PIECE COUNT  
BATCH COUNT  
BATCH AMOUNT  
18  
$14.878  
SV60941 Rev. B  
3-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 • Using the Meter  
If You Have Departmental Accounting  
1. Press the Account key repeatedly until you see the ac-  
count you want to check. Press Enter to confirm your  
selection.  
Printing Account  
Reports  
(B700 Only)  
2. Press the Value/Pieces key once. The display shows the  
total postage ($) charged to the account since the regis-  
ter was last cleared. Press the Value/Pieces key again  
to see the total number of mail pieces processed for the  
account since the register was last cleared.  
3. To clear an account's batch register (return it to zero),  
press the Value/Pieces key and, while holding it, press  
C. The display prompts “Cleared.”  
Printing an Account Report  
1. Press the Account key repeatedly until you see the ac-  
count you want to check. Press Enter to confirm your  
selection. Press the Value/Pieces key once.  
2. Place a spare envelope in the transport, as though you  
were about to print postage. The display prompts: “Acct  
Report Press Enter.”  
3. Press Enter; the meter prompts “Printing...”  
4. The meter will print a summary report like that shown  
below. When printing is done, press Enter to display the  
postage value and resume processing mail.  
AAA PB2000002  
05:45P  
SINGLE ACCOUNT REPORT  
MAR 17 95  
1
MFG ENG  
10  
ACCOUNT NUMBER  
ACCOUNT NAME  
BATCH COUNT  
$3.038  
BATCH AMOUNT  
3-8  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using the Meter • 3  
The default postage value is set at the factory or by you  
while the meter is in the setup mode. (This value is often that  
for first class mail weighing up to one ounce). This value ap-  
pears in the display after you turn the meter on and the self  
test is completed. The default value also displays automati-  
cally after the meter has been inactive for a period of time.  
Printing Postage  
Using the Default  
Value  
The meter is ready to use  
when the default value is  
shown bracketed by three  
bars. See the figure at right.  
1. Select the account to which you want to charge postage  
(B700 only, if your B700 is equipped with the optional ac-  
counting feature).  
2. (B700 only) Select the advertising slogan and/or the in-  
scription you want to use .  
3. To print postage using the default value, place your ma-  
terial (envelope, post card or tape sheet) on the transport  
face up and push it against the rear wall (1). Slide it to  
the right up to the trip mark (2) and let go as the meter  
takes the mailpiece. See the figures below.  
2
1
SV60941 Rev. B  
3-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 • Using the Meter  
4. When the meter senses the envelope, it conveys it  
Printing Postage  
Using the Default  
Value (continued)  
through the print area and into the stacker. If your meter  
is equipped with the optional moistener, follow the in-  
structions in Chapter 8 of this manual.  
5. If no change in postage value is necessary, you can in-  
sert the next envelope as soon as the previous one en-  
ters the stacker.  
1. Use the number keys to enter the postage amount you  
want. You can enter the decimal point (.) manually, or let  
the meter do it for you. For example, to set a value of 64  
cents: press the 6, 4 and Enter keys; or press the deci-  
mal (.), 6, 4 and Enter keys. In either case the result is  
.64. If you want to print a fractional value, always press  
the decimal point first. To enter 15.8¢, press the decimal  
point (.), the 1, 5, 8 and Enter keys. The meter displays  
this value as “0.158”.  
Changing the  
Postage Value  
The same principle applies if you enter a value of one  
dollar or more; you can enter the decimal point yourself,  
or let the meter do it for you. As an example, to set a  
value of $1.40: press the 1, 4, 0 and Enter keys; or press  
the 1, (.), 4 and 0 keys, then Enter. The result is 1.40.  
3-10  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using the Meter • 3  
2. If you make a mistake or change your mind, press C to  
clear the entry. The display shows “_”. Enter the amount  
you want.  
Changing the  
Postage Value  
(continued)  
3. If the display shows “Insuf Funds,” the postage amount  
you selected is more than the funds available in the me-  
ter. In this case, you may want to refill the meter. See  
Chapter 5 for instructions. You may also select a smaller  
amount of postage and continue processing mail.  
4. If the display shows “High Value” alternately with the  
postage amount selected, the meter is warning you the  
postage value is more than the high limit specified in the  
user setup mode. If you want to accept the high value,  
press Enter.  
5. The meter is ready to  
use when the postage  
value you selected is  
shown bracketed by  
three bars. Process  
your mail as explained earlier. The display returns to the  
default value after the meter has been inactive for a cer-  
tain period of time.  
You can also select a preset postage value by pressing one  
of the four memory keys—Memory 1, Memory 2, Memory  
3, Memory 4. The factory defaults for these keys are:  
Printing Postage  
Using the  
Memory Keys  
(B700 Only)  
Memory 1—First Class Letter, 1 oz.  
Memory 2—First Class Letter, 2 oz.  
Memory 3—Express Mail  
HINT: The ad slogan  
and inscription called  
up by the memory key  
remain selected even  
if you enter a differ-  
ent postage value. To  
clear this, wait until the  
meter times out or turn  
it off, then on.  
Memory 4—Priority Mail  
When the preset value appears in the display bracketed by  
three bars, the meter is ready. Process mail as described  
earlier.  
NOTE: You can program each memory key to store a specific  
postage value, advertising slogan and inscription. See the setup  
instructions in Chapter 4.  
SV60941 Rev. B  
3-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 • Setting Up the Meter  
This chapter explains how to set up the menu op-  
tions available on your postage meter.  
Using the Keyboard Setup Template................4-3  
Entering Setup..................................................4-3  
Navigating the Menus.......................................4-4  
Setting Up Options ...........................................4-4  
Menu 1:Change Language...............................4-7  
Menus 3, 4, 5 and 6: Set Memory Keys  
(B700 Only) .....................................................4-7  
Menu 7: Set Daylight Saving Time ..................4-9  
Menu 8: Select DefaultAdvertisement.............4-9  
Menu 9: Set Default Inscription  
(B700 Only) ....................................................4-10  
Menu 10: Set Account Default  
(B700 Only) ....................................................4-10  
Menu 11: Set Low FundsWarning ................. 4-11  
Menu 12: Set Postage Default Value.............4-12  
Menu 13: Set Timeout Length .......................4-13  
Menu 14: Activate Features (B700 Only) ......4-14  
SV60941 Rev. B  
4-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Menu 15: Print Setup Report (B700 Only).....4-15  
Menu 16: Print Account Report  
(B700 Only) ....................................................4-16  
Menu 17: Clear All Accounts (B700 Only) .....4-17  
Menu 18: Move Clock Ahead ........................4-18  
Menu 19: Move Clock Back...........................4-18  
Menu 20: Create Account (B700 Only)..........4-19  
Menu 22: Change Account Names  
(B700 Only) ....................................................4-21  
Menu 23: Change Supervisor Password  
(B700 Only) ....................................................4-22  
Menu 24: Enable Password (B700 Only) ......4-22  
Menu 25: Enable Accounting (B700 Only) ....4-23  
Menu 26: Set Time of Date Change..............4-24  
Menu 27: Set the Default Refill Amount ........4-25  
Menu 28: Set Printer Connection  
(B700 Only) ....................................................4-25  
Menu 29: Set Up EIU (DataLink)  
(B700 Only) ....................................................4-26  
SV60941 Rev. B  
4-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting Up the Meter • 4  
When the meter enters the Setup Mode, the keys are auto-  
matically redefined so you can enter alphabetical as well as  
numeric characters and perform other functions easily. You’ll  
find a setup template in the pocket on the inside rear cover  
of this guide. Place it over the keypad as shown. It shows  
you exactly how each key functions in the Setup Mode. You’ll  
be able to customize  
Using the  
Keyboard Setup  
Template  
a number of meter  
features to meet  
your exact needs.  
The table on the fol-  
lowing two pages  
lists all of these fea-  
tures.  
Entering Alpha Characters  
Entering Setup  
To enter an alpha character, press the appropriate function  
key (Red, Blue or Green) and the appropriate number key.  
For example,  
To enter A, press Green and 1  
To enter W, press Red and 8  
You can press the keys at the same time, or one after the  
other (color key first, number key second).  
Entering Numeric Characters  
Enter numbers  
just as you nor-  
mally would; just  
press the key.  
The setup mode  
doesn’t affect the  
operation of the  
number keys.  
SV60941 Rev. B  
4-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 • Setting Up the Meter  
Your meter offers two methods for using the setup menus  
and you can freely combine them:  
Navigating the  
Menus  
Self-Prompting Menus—If you choose this method, the  
meter leads you through the entire setup menu. The dis-  
play asks you a series of yes/no questions and instructs  
you to enter a value or text as required.  
Direct Selection (Shortcut Keys)—Use the number  
keys to select the number of the menu you want and  
press Enter. Menu numbers are shown in the flowcharts  
that follow and the detailed instructions for each setup  
procedure are arranged by menu number. You can get to  
any menu choice with no more than three keystrokes.  
B700 Only  
NOTE: Some menu choices described in this guide may not be  
available because they’re associated with optional features that  
haven’t been enabled. For example, if you don’t have depart-  
mental accounting, the setup menu items associated with it are  
not active. The meter’s display will show “Not Avail” when you  
enter an account-related menu ID while in the Setup Mode.  
B702 Only  
NOTE: Some menu options, notably 3,4,5,6,14 and 28 are avail-  
able, but are not used with B702 meters. Ignore them! Setting up  
these options will not have an effect on meter operation.  
With the meter in the default display mode, press the C and  
Enter keys at the same time. If the password feature is on,  
the meter prompts you to enter your password (up to four  
digits). Type it and press Enter to get into the Setup Mode.  
Press Exit Setup to leave the Setup Mode at any time.  
Setting Up  
Options  
4-4  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting Up the Meter • 4  
Setup Up Options (continued)  
Menu  
ID  
Go To  
Page  
Prompt  
Function  
1
Change  
Language?  
Selects the language shown in the meter's  
display.  
4-7  
B700 Only  
3
Set Memory 1 Programs a postage job that's displayed  
4-7  
Key?  
when you press the memory key. A memory  
key can store a postage value, ad slogan,  
and inscription.  
B700 Only  
B700 Only  
B700 Only  
4
6
Set Memory 2 As above.  
Key?  
4-7  
4-7  
4-7  
4-9  
4-9  
Set Memory 3 As above.  
Key?  
6
Set Memory 4 As above.  
Key?  
7
Set Daylite  
Saving Time?  
Selects daylite savig or standard time.  
8
Set Advert  
Default?  
Selects the default advertisment.  
B700 Only  
B700 Only  
9
Set Inscript  
Default?  
Selects the default inscription (if inscriptions 4-10  
are enabled).  
10  
11  
12  
13  
Set Account  
Default?  
Selects the default account  
(optional feature).  
4-10  
4-11  
4-12  
4-13  
Set Low Funds Selects the descending register amount  
that triggers the low funds warning.  
Warn?  
Set Postage  
Default?  
Sets the default postage value.  
Set Timeout  
Length?  
Sets the timeout period, i.e., that amount of  
time the meter waits following an inactive  
period before it returns to default display.  
B700 Only  
14  
Activate  
Features?  
Turns the following features on or off:  
slogan port, Electronic Interace Unit and  
inscriptions. You must have an activation  
code from PB Supply LineSM for inscrip-  
tions.  
4-14  
SV60941 Rev. B  
4-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 • Setting Up the Meter  
Setup Up Options (continued)  
Menu  
ID  
Go To  
Page  
Prompt  
Function  
B700 Only  
B700 Only  
B700 Only  
15  
Print Setup  
Report?  
Prints a report listing the setup parameters  
you've chosen (requires serial printer).  
4-15  
4-16  
4-17  
4-18  
16  
17  
18  
Print Acct  
Report?  
Prints a report listing all the accounts  
you’ve defined.  
Clear All  
Accounts?  
Clears the contents of all accounts in a  
single operation.  
Move Ahead  
Clock?  
Sets the meter’s internal clock forward by  
an amount you specify. Use this feature to  
correct clock drift.  
19  
20  
21  
22  
23  
24  
25  
26  
Move Back  
Clock?  
Same as above, but moves the clock back.  
4-18  
4-19  
4-20  
4-21  
4-22  
4-22  
4-23  
4-24  
B700 Only  
B700 Only  
B700 Only  
B700 Only  
B700 Only  
B700 Only  
Create  
Account?  
Create Sets up an account (optional fea-  
ture).  
Delete  
Account?  
Removes an account (optional feature).  
Change Acct Changes account names (optional feature).  
Names?  
Super Pswd  
Change?  
Changes supervisor password.  
Password  
Enable?  
Enables password protection.  
Enable  
Accounting?  
Enables accounting (optional feature).  
Set Time  
of Date  
Change?  
Sets the time at which the meter advances  
the date.  
27  
28  
29  
Set Refill  
Default?  
Sets a default refill amount that your meter  
displays when you add postage.  
4-25  
4-25  
4-26  
B700 Only  
B700 Only  
Set Printer Selects printer connection.This menu item  
Connection? is not available if meter has optional EIU.  
Setup EIU?  
This menu item is available only if your me-  
ter has optional EIU (DataLink).Use it to set  
up the EIU.  
4-6  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting Up the Meter • 4  
This menu lets you change the language displayed by your  
meter. The number of languages from which you can choose  
depends on what model meter you have.  
Menu 1:  
Change  
Language  
1. The display prompts “Change Language?”  
2. Press Yes.  
3. The meter prompts “Amr English?”  
4. Press Yes to accept the language; press No to see the  
next language in the list. When you see the language you  
want, press Yes. The meter advances to the next item on  
the setup menu.  
You can also select a language by entering its number. For  
example, if Amr English is 1 and Spanish is 2, select Span-  
ish, by typing 2 and pressing Enter. If you enter a number  
the meter can't accept, it displays “Error,” leaves the current  
language choice unchanged and returns to the setup menu.  
This menu option allows you to assign a certain setup to a  
memory key. The setup choices you assign include postage  
value, advertising slogan number, and inscription number.  
The meter recalls these settings whenever you press the ap-  
propriate memory key.  
Menus 3, 4, 5 and  
6: Set Memory  
Keys  
(B700 Only)  
IMPORTANT! Ad slogans and inscriptions are options which you  
can purchase at the time of your initial order, or afterwards from  
the PB Supply Line™ as explained in Chapter 8.  
The meter can have one “resident” ad slogan and up to four ad-  
ditional slogans loaded via a slogan cartridge. The meter will not  
“see” additional slogans unless the slogan cartridge is loaded as  
described in Chapter 8.  
SV60941 Rev. B  
4-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 • Setting Up the Meter  
1. The display prompts “Set Memory N Key?”  
Menus 3, 4, 5 and  
6: Set Memory  
Keys  
(B700 Only)  
(continued)  
NOTE: N is the number of the Memory Key.  
2. Press Yes.  
3. The display prompts: “Enter Amnt” and shows current  
setting.  
4. Key in the postage value you want and press Enter.  
5. The display prompts: “Enter Ad” and shows current set-  
ting.  
6. Key in the ad number you want and press Enter. (Ad  
numbers range from 0 to 5. 0=no ad. If the ad number is  
not available, the meter prompts “No Ad” and returns to  
the “Set Memory N Key?” prompt.) If you do not want an  
ad, key in 0 (zero) and press Enter.  
7. The display prompts: “Enter Inscr” and shows current  
setting.  
8. Key in the inscription number you want and press Enter.  
If you don’t want an inscription, key in 0 (zero) and En-  
ter.  
NOTE: The Appendix contains a list of inscription codes.  
If the inscription is not available, the display shows “No  
Inscript” briefly and returns to the “Set Memory N Key?”  
prompt.  
9. The display prompts “Mem N Set” (where N is the num-  
ber of the memory key) and moves on to the next item of  
the setup menu.  
4-8  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting Up the Meter • 4  
This menu lets you turn daylight saving time on or off.  
1. The display prompts “Set Daylite Saving Time?”  
2. Press Yes.  
Menu 7:  
Set Daylight  
Saving Time  
3. The meter prompts: “Set Daylite Saving On [Off]?”  
4. Press Yes or No as appropriate to respond to the prompt.  
5. The meter prompts “Daylite Time is On [Off],” depending  
on your answer in step 2.  
6. The meter prompts “Now XX:XX a(p) Press Enter” where  
XX:XX is the time.  
7. Press Enter to accept the setting. The meter advances to  
the next item on the setup menu.  
The meter automatically selects the default ad when you first  
turn it on and after it has been inactive for a certain period of  
time. You can change the default as follows:  
Menu 8:  
Select Default  
Advertisement  
1. The display prompts “Set Advert Default?”  
2. Press Yes.  
3. The display prompts “Enter Ad Number.”  
4. Use the number keys to key in the number of the ad you  
want to use as the default.  
NOTE: You’ll find ad numbers printed on your slogan car-  
tridge (see Chapter 8 for more information.) “Valid” numbers  
may range from 0 to 5. Zero (0) means no ad is selected. If  
the number you enter isn't valid, the meter briefly displays  
“No Ad,” leaves the current default ad unchanged, and re-  
turns to the “Set Advert Default?” prompt.  
5. The meter displays the ad number and ad name or  
“NONE” if you keyed in zero (0).  
6. Press Enter.  
7. The meter prompts “Ad Set” and goes to the next item in  
the setup menu.  
SV60941 Rev. B  
4-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 • Setting Up the Meter  
The default inscription is automatically selected when you  
first turn the meter on and after it has been inactive for a pe-  
riod of time. You can change the default as follows:  
Menu 9:  
Set Default  
Inscription  
(B700 Only)  
1. The display prompts “Set Inscrpt Default?”  
2. Press Yes.  
3. The display prompts “Enter Insc Number.”  
4. Key in the code number of the default inscription using  
the number keys and press Enter. (If the number you en-  
ter isn't valid—the inscription isn't available—the meter  
displays “No Inscript” for one second and returns to the  
“Set Inscrpt Default” prompt.  
NOTE: Inscriptions are options purchased at the time of  
your initial order or afterwards from the PB Supply Line™.  
See the Appendix for a list of available inscriptions and their  
code numbers.  
5. The display prompts “Inscrpt Set” and the meter goes to  
the next item in the setup menu.  
The meter selects the default account automatically when  
you first turn it on and after it's been inactive for a while. You  
can change the default account as follows:  
Menu 10:  
Set Account  
Default  
(B700 Only)  
1. The display prompts “Set Account Default?”  
2. Press Yes.  
3. The display shows the current default account name.  
NOTE: This menu  
item is not available  
when the password  
feature—Menu Item  
24—is enabled.  
4. Press No repeatedly to cycle through the available ac-  
count names or key in the account ID number and press  
Enter. (Account ID numbers range from 1 to 10. If you  
have the optional Electronic Interface Unit [“Datalink”],  
they range from 1 to 100.)  
NOTE: If the meter can't accept the number you enter, it will  
prompt “Error” and return you to the “Set Account Default?”  
prompt.  
5. When you’ve selected the account name you want, press  
Enter.  
6. The meter prompts “Account Set” and moves to the next  
item in the setup menu.  
4-10  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting Up the Meter • 4  
The meter warns you when the descending register ($ Avail-  
able) reaches a certain default value. You can set a different  
amount as follows.  
Menu 11:  
Set Low Funds  
Warning  
1. The display prompts “Set Low Funds Warn?”  
2. Press Yes.  
3. The display prompts “Enter Amnt” and shows the current  
value.  
4. Key in the low funds amount using the number keys and  
press Enter. You must enter the decimal point. For ex-  
ample, press the 5, 0, (.) and Enter keys for a low funds  
warning amount of $50.  
5. The display prompts “Amount Set” and the meter ad-  
vances to the next item in the setup menu.  
NOTE: If you enter a value the meter can't accept, it  
prompts “Value Error,” leaves the original default value un-  
changed and returns to the “Set Low Funds Warn?” prompt.  
If you make a mistake while entering the new value, or de-  
cide not to change it, press C (Clear), then Enter. The low  
funds amount will not change and the meter returns to the  
“Set Low Funds Warn” prompt.  
SV60941 Rev. B  
4-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 • Setting Up the Meter  
Your meter displays the default postage value when you first  
Menu 12:  
Set Postage  
Default Value  
turn it on and when it has been inactive for a period of time.  
Think of the default as a standard value the meter always  
returns to. The factory-set default is the current rate for first  
class postage for mailpieces weighing up to one ounce. You  
can change this setting as follows:  
1. The display prompts "Set Postage Default?”  
2. Press Yes.  
3. The display prompts: “Enter Amnt” and shows the current  
value.  
4. Key in the default value using the number keys and  
press Enter. You can key in the decimal point or let the  
meter do it for you. For example, press 3, 2, and Enter to  
enter $0.32.  
5. The display prompts “Amount Set” and the meter ad-  
vances to the next item in the setup menu.  
NOTE: If you enter a value the meter can't accept, it  
prompts “Error,” leaves the current default value unchanged  
and returns to the “Set Postage Default?” prompt.  
If you make a mistake while entering the new value, or  
decide not to change it, press Clear, then Enter. The de-  
fault postage amount remains unchanged and the meter  
returns to the “Set Postage Default” prompt.  
4-12  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting Up the Meter • 4  
The timeout length is the amount of time in minutes the me-  
ter waits following an inactive period before it returns to the  
default display. To change the timeout value:  
Menu 13:  
Set Timeout  
Length  
1. The display prompts “Set Timeout Length?”  
2. Press Yes.  
3. The display prompts “Enter Time” and shows current  
timeout setting.  
4. Key in the timeout value in minutes using the number  
keys and press Enter. The timeout value can range from  
0 to 1,440 minutes (24 hours). For example, press 1, 0  
and Enter to enter a timeout value of ten minutes. If you  
want to disable the timeout feature, enter 0 (zero).  
5. The display prompts “Timeout Set” and advances to the  
next item in the setup menu.  
NOTE: If you enter a timeout value the meter can't accept (you  
chose a number outside of the minimum and maximum limits),  
the display shows “Error” and returns you to the “Set Timeout  
Length?” prompt.  
SV60941 Rev. B  
4-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 • Setting Up the Meter  
Use this option to enable (turn on) or disable (turn off) certain  
optional meter features. These include additional inscriptions.  
Menu 14:  
Activate Features  
(B700 Only)  
You need a special code number to activate these features.  
The PB Supply Line™ will give it to you when you place your  
order.  
1. The display prompts "Activate Features?”  
2. Press Yes.  
3. The display prompts “Enter Code.”  
4. Key in the code for the feature you want to enable or dis-  
able; press Enter.  
NOTE: If you enter a bad code number (wrong number of  
digits or the code doesn't match any of the features in the  
meter), the meter displays “Error” and returns to the “Enter  
Code” prompt.  
5. The display prompts “Enabled” or “Disabled,” depending  
on the code you entered.  
6. The display prompts “Enter Code.” To enable or disable  
another feature, repeat steps 4 and 5. To return to the  
main setup menu, press Enter.  
4-14  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting Up the Meter • 4  
Use this menu option to print a report summarizing the setup  
options you've chosen.  
Menu 15:  
Print Setup  
Report  
(B700 Only)  
NOTE: This menu option is not available unless you select  
a printer connection. Follow the instructions given for Menu  
28—Set Printer Connection (page 4-25). Your meter must be  
connected to a serial printer either directly or through the option-  
al Electronic Interface Unit in order to print this report. Make sure  
your printer is ON, set to ON LINE and loaded with paper before  
you print.  
1. The display prompts “Print Setup Report?"  
2. Press Yes.  
3. The display prompts “Printing...”  
4. Your serial printer produces a report similar to that shown  
below.  
NOTE: If no printer is connected, or there is a communica-  
tions problem, the meter prompts “Error” and advances to  
the next item of the setup menu.  
5. When the report is finished, the meter advances to the  
next item of the setup menu.  
SETUP REPORT  
MAR 17 95  
AAA  
20000002  
ASCENDING REGISTER  
DESCENDING REGISTER  
10000.00$  
1000.00$  
CONTROL SUM  
11000.00$  
METER PIECE COUNT  
BATCH COUNT  
BATCH AMOUNT  
500  
500  
1000.00$  
INSCRIPTION LIST........................................................................  
INS ID  
19  
29  
18  
31  
INS NAME  
First Class  
Nonprofit Org  
Carrier Presort  
Nonprofit ZIP+4  
*************************************************************************  
Sample Setup Report  
SV60941 Rev. B  
4-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 • Setting Up the Meter  
Use this option to print a report summarizing the contents of  
all the accounts defined for the meter.  
Menu 16:  
Print Account  
Report  
1. The display prompts “Print Accnt Report?”  
2. Press Yes. (If you press No, the meter goes to the next  
item in the setup menu.)  
(B700 Only)  
3. The display prompts “Insert Form.”  
4. Place a spare envelope or index card on the meter’s  
deck, up against the rear wall and slide it to the right.  
5. The display says “Printing...” and the meter prints the  
first page of the report.  
6. If the report is complete, the meter takes you to the next  
item in the setup menu. If a second page is needed, the  
display prompts “Insert Form” again. In this case, repeat  
steps 4 and 5.  
MULTI-ACCOUNT REPORT  
MAR 17 95  
AAA  
05:14P  
PB2000002  
No  
01  
02  
03  
04  
05  
Pieces Postage  
No  
06  
07  
08  
09  
10  
Pieces Postage  
270  
4
$89.10  
$11.84  
$0.00  
540  
0
$178.20  
$0.00  
0
0
$0.00  
683  
0
$437.12  
$0.00  
683  
0
$437.12  
$0.00  
Typical Multi-Account Report  
IMPORTANT! If your meter is equipped with the optional Dat-  
aLink, also known as an Electronic Interface Unit (EIU), it can  
assign postage charges to up to 100 unique departmental ac-  
counts. This application requires a serial printer to produce the  
multi-account report. Please refer to the instructions furnished  
with your DataLink.  
4-16  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting Up the Meter • 4  
Use this menu choice to clear the contents of all accounts in  
a single operation.  
Menu 17:  
Clear All  
Accounts  
(B700 Only)  
CAUTION! Make certain you really want to clear all  
account registers. Once you do so, you can't undo the  
operation.  
1. The display prompts “Clear All Accounts?”  
2. Press Yes.  
3. The display prompts: “To Confirm Press Yes.”  
4. Press Yes to clear all accounts. The display will blank out  
for a short time and then show “Cleared” for one second.  
The meter then takes you to the next item in the setup  
menu.  
5. If you press No—or any other key—while the confirma-  
tion prompt is showing, accounts are not cleared and the  
meter advances to the next item in the setup menu.  
6. If you’d like to clear a single account, see page 3-8, If  
You Have Departmental Accounting, for instructions.  
SV60941 Rev. B  
4-17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 • Setting Up the Meter  
Use these menus to adjust the meter's clock.  
Menu 18:  
Move Clock  
Ahead  
1. The display prompts “Move Ahead Clock?” or “Move  
Back Clock?” depending on the menu you're in.  
2. Press Yes.  
and  
3. The display prompts “Now XX:XXa(p) Press Enter”  
where XX:XX is the current time displayed by the me-  
ter's internal clock. For example:  
Menu 19:  
Move Clock Back  
Now  
11:34p  
Press Enter  
4. Press Enter.  
5. The display prompts: “Enter Mins To Advance” or “Enter  
Mins To Set Back,” depending on which menu you're in.  
6. Key in the number of minutes you want to either ad-  
vance or set back the clock. You can adjust the clock up  
or down by a maximum of 120 minutes. If you enter a  
value the meter can't accept, the display prompts “Error,”  
leaves the time unchanged and lets you start over.  
NOTE: Once you’ve moved the clock ahead or back, you no  
longer have the full adjustment range of 120 minutes. The  
range is reduced by previous adjustments. For example, if  
you set the clock back by 30 minutes, the adjustment range  
remaining is 90 minutes (120-30=90).  
7. Press Enter.  
8. The meter prompts “Now XX-XXa(p) Press Enter” again.  
If the setting is OK, press Enter. The meter automatically  
goes to the next item in the setup menu. If you want to  
change the setting, press C (Clear) to return to the menu  
prompt.  
4-18  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting Up the Meter • 4  
Menu 20:  
Create Account  
(B700 Only)  
In order to use this option:  
Your meter must have the optional accounting feature;  
Accounting must be enabled—see Menu 25 for instruc-  
tions;  
You must first delete an account or accounts before you  
can create one—see the instructions for Menu 21 on the  
following page. The reason for this is that when you first  
enable the accounting feature, the meter creates 10 ac-  
counts named “1” through “10”. You cannot have more  
than 10 accounts unless your meter is equipped with the  
optional Electronic Interface Unit (DataLink), in which  
case you can have up to 100. Therefore you must delete  
one or more accounts before you can create one.  
1. The meter prompts “Create Account?"  
2. Press Yes.  
3. The display prompts “ Enter Acct Name.”  
4. Key in an account name. It can be up to 11 characters  
long. To backspace, press the left arrow key ←. To type  
a space, press the right arrow key (or the blue key, then  
the decimal point key).  
5. Press Enter. Skip steps 6 and 7 if the password feature  
is not enabled.  
6. If the password feature is enabled, the meter prompts  
“Enter Acct Password.”  
7. Key in a password for the account. You can use numbers  
only and are limited to four. Press Enter.  
8. The meter prompts "Account Defined” for a few seconds  
and then “Enter Account Name.” You can create another  
account or press No to go to the next menu item.  
SV60941 Rev. B  
4-19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 • Setting Up the Meter  
To delete an account:  
Menu 21:  
Delete Account  
(B700 Only)  
1. The meter prompts “Delete Account?  
2. Press Yes.  
3. To scroll through the account names, press the No key  
repeatedly. To select the account to delete, press Yes.  
(You can also select an account by keying in its ID num-  
ber and pressing Enter.)  
4. The meter prompts “Delete?” and shows the account  
name.  
5. Press Yes to delete the account. Press No if you  
changed your mind.  
6. If you pressed Yes the meter prompts “Deleted” and ad-  
vances to the next menu item.  
7. If you pressed No the meter prompts “Delete Account?”  
Press No to advance to the next menu item.Menu 22:  
4-20  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting Up the Meter • 4  
In order to use this option:  
Menu 22:  
Change Account  
Names  
(B700 Only)  
Your meter must have the optional accounting feature;  
Accounting must be enabled—see Menu 25 for instruc-  
tions.  
To change an account name:  
1. The meter prompts “Change Acct Names?"  
2. Press Yes.  
3. The display shows the current account name.  
4. You can:  
Type in the account ID number you want to change;  
press Enter.  
Or press No repeatedly to scroll through the ac-  
count names.  
5. Press Yes to select the account name you want to  
change.  
6. The meter prompts “Name?” and shows the account  
name.  
7. Key in an account name. It can be up to 11 characters  
long. To backspace, press the left arrow ← key. To type  
a space, press the right arrow key (or the blue key then  
the decimal point key).  
8. Press Enter. Ignore steps 9 through 12 if the password  
feature is not on.  
9. If the password feature is enabled, the meter prompts:  
“PSWD” and displays the current password.  
10. To leave the password as is, press Enter.  
11. To change the password, type in a new one for the ac-  
count. You can use numbers only and cannot enter  
more than four.  
12. Press Enter.  
13. The meter prompts “Changed” and returns to the  
“Change Acct Names?” prompt. Press No if you want to  
go on to the next menu item.  
SV60941 Rev. B  
4-21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 • Setting Up the Meter  
To change the supervisor password:  
Menu 23:  
Change  
Supervisor  
Password  
(B700 Only)  
1. The meter prompts “Super Pswd Change?"  
2. Press Yes.  
3. The meter prompts "Enter Super Password.”  
4. Key in the new password. You may use numbers only  
and cannot enter more than four.  
5. Press Enter.  
6. The meter prompts “Changed” and advances to the next  
menu item.  
Password protection is a feature that offers an additional  
measure of security by limiting access to certain meter op-  
erations to authorized personnel only.  
Menu 24:  
Enable Password  
(B700 Only)  
IMPORTANT! Password protection is available only when the  
meter’s accounting feature is activated and in use.  
To use this feature:  
1. The meter prompts “Password Enable?"  
2. Press Yes.  
3. The meter prompts "To Enable Press YES.”  
4. Press Yes.  
5. The meter prompts “Enter Super Password.”  
6. Key in the supervisor's password. You may use numbers  
only and you may not enter more than four. If the meter  
can’t accept the password, it prompts “Error” and returns  
to the “Password Enable?” prompt.  
7. Press Enter.  
8. The meter prompts “Enabled” and goes to the next menu  
item.  
NOTE: With password protection enabled, you must enter the  
supervisor password to get into the meter's setup mode.  
4-22  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting Up the Meter • 4  
Accounting is an optional feature that let's you charge post-  
age to a particular account. When you enable this feature,  
the meter creates 10 accounts and automatically assigns the  
names “1” to “10” to them. If passwords are used, turn them  
on after enabling accounting and setting up accounts (See  
page 4-22). Once you enable the accounts feature you can  
change account names, delete accounts, create accounts  
and assign password protection to them. To enable this fea-  
ture:  
Menu 25:  
Enable  
Accounting  
(B700 Only)  
1. The meter prompts “Enable Accounting?"  
2. Press Yes.  
3. The meter prompts "To Enable Press YES.”  
4. Press Yes.  
5. The meter prompts “Enabled.”  
NOTE: With accounting enabled, the meter will ask for an  
account name when you turn it on (if you’ve set up a default  
account, the display will show the account ID number). You can  
disable accounting by pressing No when the display prompts “To  
Enable Press Yes.” When you disable accounting, the meter will  
save your account names and any account data that has accu-  
mulated. These will appear when you enable accounting again.  
SV60941 Rev. B  
4-23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 • Setting Up the Meter  
This menu choice lets you change the time at which the me-  
ter advances the date. This is usually set to occur at 12:00  
A.M.  
Menu 26:  
Set Time of  
Date Change  
1. The meter prompts “Set Time of Date Change.”  
2. Press Yes.  
3. The meter prompts "Now 12:00a Press Enter.” (This is  
the current setting.)  
4. Press Enter.  
5. The meter prompts “Enter Hour.”  
6. Type in the hour you want using the number keys on  
the keyboard. You can type an hour from 1 to 12. Press  
Enter. If you enter an invalid number, the meter will dis-  
play “Error” and return to the “Set Time of Day” prompt.  
If you make a mistake while entering a number, press C  
to clear it. The meter prompts “—.” Enter the value you  
want.  
7. The meter prompts “Enter Min.”  
8. Type in the minutes you want. You can type numbers  
ranging from 00 to 59. Press Enter. If you enter an in-  
valid number, the meter will display “Error” and return to  
the “Set Time of Day” prompt.  
9. Meter prompts “AM?”  
10. Press Yes for AM; No for PM.  
11. Meter prompts “Now XX:XXa(p) Press Enter” again  
where XX:XXa(p) is the new time for the date change. If  
the setting is OK, press Enter. The meter will automati-  
cally go to the next item on the setup menu.  
4-24  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting Up the Meter • 4  
This menu choice lets you set the default refill amount shown  
by the meter when you add postage using Pitney Bowes  
Postage By Phone® service.  
Menu 27:  
Set the Default  
Refill Amount  
1. The meter prompts “Set Refill Default.”  
2. Press Yes.  
3. The meter prompts "Enter Amnt” and shows the current  
refill value.  
4. Key in the new refill amount. You don’t have to type the  
decimal point.  
5. Press Enter.  
6. The meter prompts “Amount Set” and advances to the  
next menu item.  
Your meter is equipped with a communications port that al-  
lows you to connect it to a serial printer or a Pitney Bowes  
Electronic Scale. The printer can produce the reports listed  
below:  
Menu 28:  
Set Printer  
Connection  
(B700 Only)  
Setup Report  
Multi-Account Report (available only when your meter is  
equipped with the optional Electronic Interface Unit (Dat-  
aLink); this option expands departmental accounting to  
100 accounts).  
Service Report (can be accessed and printed only by  
Pitney Bowes Service Personnel).  
Menu Option 28 lets you specify the type of printer connec-  
tion.  
IMPORTANT! If your meter is equipped with the optional Elec-  
tronic Interface Unit (DataLink), this menu option is not available.  
SV60941 Rev. B  
4-25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 • Setting Up the Meter  
1. The meter prompts “Set Printer Connection?”  
Menu 28:  
2. Press Yes.  
Set Printer  
Connection  
(B700 Only)  
(continued)  
3. Press No repeatedly to cycle through the available op-  
tions:  
None?— Select this option if your meter is connect-  
ed to a Pitney Bowes Electronic Scale.  
Direct?— Select this option if your meter is connect-  
ed to a serial printer.  
4. When you’ve selected the option you want, press Yes or  
Enter to confirm it. The meter prompts “Connection Set”  
and advances to the next menu item.  
This setup option is available only if an Electronic Interface  
Unit is connected to your meter. The EIU or “DataLink” is an  
expansion module that allows your postage meter to com-  
municate with other devices such as a Pitney Bowes elec-  
tronic scale. It also offers support for up to 100 departmental  
accounts.  
Menu 29:  
Set Up EIU  
(DataLink)  
(B700 Only)  
1. The meter prompts “Set Up EIU?”  
2. Press Yes.  
3. Follow the instructions furnished with your EIU (Pitney  
Bowes Publication SV50394).  
4-26  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5 • Refilling Your Meter  
This chapter contains the information you'll need  
to obtain postage funds for your B700/B702 meter  
without leaving your office. All you need is a phone  
or internet access and a few minutes of your time.  
Obtaining the Current Meter Access Code.......5-2  
Obtaining the Refill Combination......................5-3  
Entering Your Refill Amount into the Meter.......5-5  
Payment Options..............................................5-5  
Performing an Inspection on Your Meter........5-10  
SV60941 Rev. B  
5-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5 • Refilling Your Meter  
To obtain your meter’s current access code:  
Obtaining the  
Current Meter  
Access Code  
1. Press the Refill button. Your default reset amount will  
display.  
2. Press the Enter button if you wish to refill for the amount  
shown, OR enter a new amount, and then press the En-  
ter button to confirm.  
3. Insert a spare envelope or index card as a form (this will  
run through the machine) OR press the Enter button  
again.  
Depending on the action you take, your current access  
code will either display or will print on the envelope or  
index card you ran through the machine.  
NOTE: Your access code changes as you use postage, so be  
sure to obtain the current access code each time you refill your  
meter.  
5-2  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Refilling Your Meter • 5  
Obtaining  
the Refill  
Combination  
NOTE: You can refill you meter either on the internet or on the  
phone.  
Refilling Your Meter on the Internet  
In order to refill your meter on the internet, you will need your  
User ID, password, meter serial number, and current access  
code from Obtaining the Current Meter Access Code, on  
page 5-2.  
2. Enter your User ID and password. Click Login.  
3. On the "Transactions" page:  
a. Click on Refill Your Meter.  
b. Enter your 7-digit meter serial number. If prompted,  
click Continue.  
4. On the "Refill Meter" page:  
a. Enter the current meter access code.  
b. Enter the Refill Amount you wish to add to your me-  
ter.  
c. Click Continue.  
5. On the "Verify Your Choices" page:  
Click Refill Meter if all information is correct, OR  
Click Re-enter Amount to change the dollar amount.  
Your Setting Combination displays on the "Meter Refill Con-  
firmed" page. You can now go to your meter and follow the  
steps in Entering Your Refill Amount into the Meter on page  
5-5.  
SV60941 Rev. B  
5-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5 • Refilling Your Meter  
Refilling Your Meter on the Phone  
Obtaining  
the Refill  
Combination  
(continued)  
In order to refill your meter on the phone, you will need your  
account number, meter serial number, and current access  
code from Obtaining the Current Meter Access Code, on  
page 5-2.  
1. Dial 1-800-243-7800 (available 24 hours/day, 7 days/  
week).  
2. Key in your 8-digit Postage By Phone® account number  
followed by the # key.  
3. Select option 1 to add postage to your meter.  
4. If prompted, key in your 7-digit meter serial number fol-  
lowed by the # key.  
5. Key in the current meter access code followed by the #  
key.  
6. Key in the dollar amount you wish to add to your meter,  
in whole dollars only followed by the # key (for example:  
to add $200 key 200#).  
7. The system will verify the amount – if correct, press the #  
key again.  
8. The phone system will give you a 6-digit refill combina-  
tion for this request; write this number down.  
You can now end your call and follow the steps in Entering  
Your Refill Amount into the Meter on page 5-5.  
NOTE: If at any time during this process you have a question,  
press “0” for an agent (available M-F, 8am-8pm, EST).  
5-4  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Refilling Your Meter • 5  
If you have printed a form:  
Entering Your  
Refill Amount  
into the Meter  
Your display should read "Enter Combo".  
Key in the 6-digit setting number and press the Enter  
button. Your display will read "Refill OK" and the postage  
available.  
If you have not printed a form:  
Your meter should be displaying your current access  
code. Press Enter. The display will read "Enter Combo."  
Key in the 6-digit setting number and press the Enter  
button. Your display will read "Refill OK" and the postage  
available.  
Purchase Power®  
Payment Options  
As a Purchase Power or Postal Privilege customer, you can  
order postage now and pay later when you get your bill.  
When you receive your invoice, simply write a check payable  
to Purchase Power or Postal Privilege (Please be sure your  
11-digit account number is referenced) and send it with your  
invoice stub to:  
Regular Mail Address:  
Purchase Power/Postal Privilege  
P.O. Box 856042  
Louisville, KY 40285-6042  
Overnight Mail Address:  
Purchase Power/Postal Privilege  
5101 Interchange Way  
Louisville, KY 40229  
SV60941 Rev. B  
5-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5 • Refilling Your Meter  
Reserve Account  
Payment Options  
(continued)  
Today, when you send a postage check in advance, you re-  
ceive no added value. At Pitney Bowes, we believe important  
customers like you deserve more. By sending your pre-pay-  
ment checks to Reserve Account, you’ll earn FREE POST-  
AGE based on your average daily account balance. This is  
the smartest way to make postage payments earn money for  
you!  
Schedule Electronic Payments – We’ve added a new  
payment-scheduling feature to make funding your Post-  
age By Phone® Reserve Account even easier! By signing  
up online at www.postagebyphone.com, you can fund  
your account by scheduling postage payments weekly,  
monthly, or once your account balance reaches a speci-  
fied level.  
ACH Credit instructions for your Reserve Account  
If you send an ACH Credit, your funds will be posted  
to your account within 2 business days by 6:00 pm East-  
ern Time. Use the following information to send an ACH  
Credit:  
Remit To:  
Reserve Account C/O  
Pitney Bowes Bank  
Routing Number:  
1240-8462-7  
Credit to Account Number: Your 8-Digit Postage By  
Phone® Account #  
Company Name:  
Your Company Name  
Acceptable ACH Credit formats: CTX, CCD/CCD+,  
PPD/PPD+  
5-6  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Refilling Your Meter • 5  
Bank-to-Bank Wiring instructions for your Reserve  
Account – If you send a Bank or Federal Wire by 1:00  
pm Eastern Time, your account is updated the same day  
by 6:00 pm Eastern Time. Use the following information  
to send a Wire:  
Payment Options  
(continued)  
Destination Bank:  
National City Bank  
Kentucky  
Routing Number:  
City, State:  
083000056  
Louisville, KY  
FDN (Beneficiary):  
Pitney Bowes Bank, Inc.  
Reserve Account  
AC (Account Number): 754401126  
OBI (Other Information): Your 8-Digit Postage By  
Phone® Account #  
Company Name:  
Your Company Name  
If you choose to mail your deposit, make your checks pay-  
able to Reserve Account and write your 8-digit Postage By  
Phone® account number on the check. Include a deposit slip  
with every payment. These slips are located on the bottom  
of your Postage By Phone® statement or can be ordered on-  
line at www.postagebyphone.com. Allow 5 business days for  
Regular Mail or 2 business days for Overnight Mail and send  
deposits to:  
Regular Mail Address:  
Reserve Account  
P.O. Box 856056  
Louisville, KY 40285-6056  
Overnight Mail Address:  
Reserve Account  
5101 Interchange Way  
Louisville, KY 40229  
SV60941 Rev. B  
5-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5 • Refilling Your Meter  
United States Postal Service  
Payment Options  
(continued)  
ACH Debit (EFT) – If you would like to be one of our  
ACH debit customers, please apply online at  
www.postagebyphone.com and click on Pay For Post-  
age.  
Bank-to-Bank Wiring or ACH Credit – If you send a  
Bank or Federal Wire by 1:00 pm Eastern Time, your  
account is updated the same day. If you send an ACH  
Credit, your funds will be posted to your account within 2  
business days by 6:00 pm Eastern Time. Use the follow-  
ing information to send a Wire or an ACH Credit:  
Citibank  
CMRS/Pitney Bowes Postage By Phone  
Account # 4067-8633  
Routing Transit #021000089  
Detail Payment Field: XXXXXXXX  
-
-
Acceptable ACH Credit formats: CTX, CCD/CCD+,  
PPD/PPD+  
(X’s are your 8-digit Postage By Phone® account  
number)  
If you choose to mail your deposit to the United States Postal  
Service, make your check payable to United States Postal  
Service, and write your 8-digit Postage By Phone® account  
number on the check.  
Include a deposit slip coupon with every payment (these  
coupons will be provided and replenished automatically by  
the Postal Service).  
5-8  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Refilling Your Meter • 5  
Mail your deposit to one of the Lockbox addresses reflected  
below (the most efficient location in terms of mail service will  
be reflected on your deposit slip coupons).  
Regular Mail Addresses - (Allow 5 business days)  
CMRS-PB  
P.O. Box 7247-0166  
Philadelphia, PA 19170-0166  
CMRS-PB  
P.O. Box 0566  
Carol Stream, IL 60132-0566  
CMRS-PB  
P.O. Box 894766  
Los Angeles, CA 90189-4766  
SV60941 Rev. B  
5-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5 • Refilling Your Meter  
Postal regulations require a meter holder to contact the man-  
Performing an  
Inspection on  
Your Meter  
ufacturer periodically to add postage or perform an inspec-  
tion. If you do not add postage within a 90-day period, your  
meter will begin flashing “Insp. Due” but will still allow you to  
run postage.  
If you do not add postage or perform an inspection within  
the next 30 days, your meter will flash “Insp. Req.” and stop  
printing postage.  
You can satisfy this requirement by calling our automated  
system at 1-800-243-7800 and adding postage or if you do  
not need postage, by performing an inspection. Below are  
the steps to perform an inspection:  
Obtaining the Current Meter Access Code  
To obtain your meter’s current access code:  
1. Press the Refill button. Your default reset amount will  
display.  
2. Press the number 5 and then press Enter.  
3. Press the Enter button again.  
4. Your current access code displays. Write this number  
down.  
5. Press the Enter button again.  
5-10  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Refilling Your Meter • 5  
Performing the Inspection  
In order to perform your meter inspection, you will need your  
account number, meter serial number, and access code from  
the steps above.  
Performing  
an Inspection  
on Your Meter  
(continued)  
1. Dial 1-800-243-7800.  
2. Key in your 8-digit Postage By Phone® account number  
followed by the # key.  
3. Select option 4 to perform a meter inspection.  
4. If prompted, key in your 7-digit meter serial number fol-  
lowed by the # key.  
5. Key in the current meter access code followed by the #  
key.  
The voice response system will respond with a 4-digit combi-  
nation. You can now end your call.  
Entering Your Combination in the Meter  
Your meter should be displaying “Enter Combo”. Key in the  
4-digit combination issued in the steps above and press the  
Enter button.  
Your meter will display "Refill OK" and the postage will be  
available.  
SV60941 Rev. B  
5-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6 • Replacing the Ribbon  
This chapter contains the procedure to remove  
and replace the ribbon cassette in your postage  
meter.  
Removing the Used Ribbon Cassette ..............6-2  
Installing the New Cassette..............................6-4  
SV60941 Rev. B  
6-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6 • Replacing the Ribbon  
The meter's display shows “Low Ribbon” when the supply  
Removing the  
Used Ribbon  
Cassette  
is about to run out. You can still print postage when you see  
this warning. If you see “Ribbon Out,” replace the cassette  
immediately.  
IMPORTANT! If you attempt to use an exhausted ribbon cas-  
sette, you may pay for postage without getting a valid meter  
imprint.  
1. Turn the key counterclockwise to switch the meter OFF.  
U
L
2. Open the cassette compartment door.  
6-2  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Replacing the Ribbon • 6  
3. Squeeze the locking tab as shown to disengage the cas-  
sette.  
Removing the  
Used Ribbon  
Cassette  
(continued)  
4. Pull the cassette straight out and discard it.  
SV60941 Rev. B  
6-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6 • Replacing the Ribbon  
1. Unwrap the new  
Installing the  
New Cassette  
cassette and pull the  
shipping tab from its  
back.  
2. If necessary, turn  
the winder slightly  
counterclockwise to  
take up any slack in  
the ribbon.  
3. Hold the new cassette with the ribbon side down and the  
opening (print head cutout) aligned with the printhead.  
Rest the cassette on the deck. Align the locating tab on  
the right side of the cassette with the groove in the cas-  
sette compartment. See the figure below.  
6-4  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Replacing the Ribbon • 6  
4. Push the cassette back into the ribbon compartment as  
far as it will go. Firmly press on the upper part of the cas-  
sette near the locking tab to snap it into position.  
Installing the  
New Cassette  
(continued)  
IMPORTANT! Make sure the cassette snaps into place for  
proper operation.  
5. Close the cassette compartment door.  
6. Switch the meter ON and resume normal operation.  
CAUTION! The printhead needs no maintenance.  
Please don't touch it with your fingers or any object;  
you could damage it.  
SV60941 Rev. B  
6-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7 • Troubleshooting  
This chapter lists provides you with definitions of  
error and warning message you may receive on  
your postage meter.  
Error and Warning Messages...........................7-2  
Fault Messages................................................7-2  
If You Need Service..........................................7-2  
SV60941 Rev. B  
7-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7 • Troubleshooting  
The table on the following pages lists error and warning mes-  
Error and  
Warning  
Messages  
sages you might see while using your meter. An error mes-  
sage alerts you to a fault which, until you correct it, prevents  
the meter from tripping. A warning message alerts you to a  
condition that needs attention, but doesn't prevent meter trip-  
ping.  
NOTE: Whenever the postage amount displayed is bracketed  
by three wings, as shown below, the meter is ready to print post-  
age. If the amount is bracketed by one set of wings, you can't  
process mail until you fix the fault.  
Meter is ready to print postage.  
Meter not ready. It won't trip until you  
respond to the error or warning mes-  
sage.  
If the meter senses a fault it can't correct, it displays the  
message “FATAL NN” where NN is a code that represents  
the type of fault. When this display appears, you won't be  
able to enter many keyboard commands and the meter won't  
trip.  
Fault Messages  
You may be able to correct the problem by turning the meter  
off for a few seconds, and turning it back on. If this doesn't  
correct the problem, please write down the error code and  
call for service.  
Pitney Bowes provides service from most of the major cit-  
ies of the United States through a nationwide, computerized  
dispatching network. Should you have questions about your  
postage meter or require assistance with your particular ap-  
plication, visit our web site:  
If You Need  
Service  
www.pitneyworks.com/metersupport or call 1-800-522-0020.  
7-2  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting • 7  
Error and Warning Messages  
Bad PrintHd  
The meter has detected a printhead problem. Call for service.  
Check EIU (B700 Only)  
There is a communication problem between your meter and the EIU (DataLink). Unplug  
the power cord for 30 seconds, then plug it in to restart the meter. If this fails to correct the  
problem, call for service.  
Clear Jam  
The mailpiece has jammed on the feed deck. To clear the jam, turn the meter off, then on.  
This causes the transport to release the envelope. Carefully pull the envelope out to the  
Left to avoid damaging the ribbon.  
Date Change  
Normal. Occurs at midnight (unless you specified another time) when the meter automati-  
cally advances the date.  
Date Error  
Check the date.  
Error  
You entered an “illegal” value, that is, a value the meter can't accept.  
Fatal 09  
The meter displays this message after nine consecutive, unsuccessful attempts to refill it.  
You cannot refill the meter at this point. Please call for service.  
Fatal NN  
The meter has a fault which prevents it from operating. "NN" is a code that indicates the  
nature of the fault to Pitney Bowes Service personnel. You may be able to recover the me-  
ter from a Fatal 14 fault by turning it off, waiting a few seconds, then turning it on. If the me-  
ter fails to display the default postage amount after you do this, write down the error code  
and please call for service.  
High Value  
The postage value you selected is greater than the high value limit set for your meter. This  
is a warning only; you can accept the value and process the mailpiece by pressing Enter.  
SV60941 Rev. B  
7-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7 • Troubleshooting  
Error and Warning Messages  
Inspect Due  
The meter is alerting you that a postal inspection is due which you will need to perform. Call  
the Postage By Phone® Data Center at 1-800-243-7800 (1-800-243-2300 in Alaska and  
Hawaii). When you hear the recording, press 0 and the asterisk (*) key for assistance. You  
may still use your meter after you see this message. If you fail to have the meter inspected,  
you will see the “Inspection Req” prompt. At this point, the meter is locked out, preventing  
you from using it until the inspection is completed.  
Inspect Req  
This message alerts you that the meter requires a mandatory inspection. The meter is  
locked out: you cannot print postage. Call the Postage By Phone® Data Center using the  
numbers above for help.  
Insuf Funds  
The postage value selected is more than the funds currently available in the meter. You can  
select a lesser amount of postage. You should also refill the meter at this time (Chapter 5).  
Low Funds  
The descending register ($ Available) has reached the low funds warning amount. You  
should refill the meter at this point. See the instructions in Chapter 5. You may continue us-  
ing the meter until you see the “Insuf Fund” message.  
Low Ribbon  
The ribbon supply is nearly exhausted. About 80% of the supply is gone at this point. Make  
sure you have a new cassette on hand. You can continue using your meter until you see  
the Ribbon Out error message.  
Need Accnt (B700 Only)  
If your meter has the optional accounting feature enabled, you must enter a valid depart-  
mental account to which postage is charged. If you fail to do so, you'll see this message.  
Enter the account using the Account key (Chapter 3) and then select the postage value  
you want.  
No Inscript (B700 Only)  
The selected inscription is not available; inscriptions have not been enabled. See Chapter 4  
for instructions on activating features.  
7-4  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting • 7  
Error and Warning Messages  
No Ribbon  
The ribbon is exhausted, broken or no ribbon cassette is loaded. Replace the ribbon cas-  
sette (Chapter 6), close the cassette door and press Enter.  
Please Wait  
Printhead temperature is out of range. Wait until it warms up.  
Press Enter to Restart  
Press Enter to restart the meter.  
Remove Mail  
The mailpiece did not complete its path through the print area. Carefully remove the mail-  
piece from the transport and reinsert it.  
Ribbon Out  
The ribbon supply is critically low; you must press Enter after each mailpiece is processed.  
Replace the ribbon cassette immediately (Chapter 6).  
No Ad  
The selected slogan is not available. See Chapter 8 for instructions on loading ad slogan  
cartridges.  
Value Error  
You entered an "illegal" value, that is, a value the meter can't accept.  
SV60941 Rev. B  
7-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8 • Supplies and Options  
This chapter lists the various supplies and options  
available with your postage meter.  
Advertising Slogan Cartridge............................8-2  
Moistener (B700 Only) .....................................8-3  
DataLink (Electronic Interface Unit)  
(B700 Only) ......................................................8-6  
Ordering Supplies and Options ........................8-6  
SV60941 Rev. B  
8-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8 • Supplies and Options  
The advertising slogan car-  
Advertising  
Slogan Cartridge  
tridge is a versatile plug-in  
option that contains up to  
four customer ads. A wide  
variety of standard ads is  
available direct from the PB  
Supply LineTM as explained  
later in this chapter. You  
can also order customized  
ads to turn your unused en-  
velope space into a highly  
visible, hard-working promo-  
tional tool. (B700 only–The  
slogan cartridge may also  
1.  
2.  
3.  
4.  
contain additional postal inscriptions.)  
Using the Slogan Cartridge  
1. Hold the slogan cartridge  
as shown—with the label  
facing the front of the  
meter—and gently push  
it into the cartridge well  
as far as it will go.  
2. A slogan cartridge holds  
up to four ads. The car-  
tridge label shows a  
picture of each ad identi-  
fied by number (figure  
above).  
.
8-2  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Supplies and Options • 8  
3. To select an ad, press the Ad key repeatedly until you  
see the ad name you want. Press Enter to confirm your  
selection. The meter's display then shows the postal  
amount.  
Advertising  
Slogan Cartridge  
(continued)  
When the meter is in the Ad Mode, you can also choose  
an ad by typing its number on the meter's keypad  
and pressing Enter. If an ad isn't available, the meter  
prompts “No Ad.”  
NOTE: Ads are not available for use if you remove the slo-  
gan cartridge from its well  
The moistener is an option designed to moisten and help  
seal envelopes as they feed into the postage meter. The in-  
structions below tell you how to attach, fill, use and maintain  
your moistener.  
Moistener  
(B700 Only)  
Attaching the Moistener  
1. Place the moist-  
ener assembly  
to the left of the  
meter as shown at  
the right.  
2. Slide the moisten-  
er to the right up  
against the meter.  
Align the pie-  
shaped back wall  
of the moistener  
with the smaller  
pie-shaped wall of  
the meter. These  
areas are shaded  
in the accompanying figure.  
3. When the blue lock lever snaps up level with the meter  
deck, the moistener is fully locked into position.  
SV60941 Rev. B  
8-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8 • Supplies and Options  
Filling Moistener  
Moistener  
(B700 Only)  
(continued)  
1. Pour E-Z Seal® solu-  
tion into the fill hole of  
the moistener brush  
assembly.  
2. Fill until the solution  
level reaches the top  
of the sight glass. DO  
NOT overfill.  
Sight Glass  
Using the Moistener  
1. Select the postage  
value you want, just as  
you normally would.  
NOTE: You can use  
tap water in the moist-  
ener. But we strongly  
recommend that, for  
best results, you use  
E-Z Seal® instead. It  
prolongs the life of the  
moistener brush and  
reduces maintenance  
requirements.  
2. Open the envelope flap  
and feed it under the  
moistener brush as-  
sembly as shown.  
3. Guide the envelope up  
against the rear wall  
and to the right until its  
lead edge reaches the  
trip mark on the meter's  
deck.  
4. The meter will then convey the envelope through the  
printer and into the stacker.  
5. To fully seal some flaps, you may have to compress the  
mailpiece by hand after metering.  
8-4  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Supplies and Options • 8  
Bypassing the Moistener  
Keep the envelope flap closed as you feed it over the moist-  
ener brush (that is, on top of the brush). See figure below,  
right.  
Moistener  
(B700 Only)  
(continued)  
USE  
BYPASS  
Maintaining the Moistener  
1. Using E-Z Seal® will  
reduce the amount of  
maintenance required.  
See page 8-6 for or-  
dering instructions.  
2. Periodically remove  
the wick assembly and  
wipe excess envelope  
glue off the deck with a  
damp sponge or paper  
towel.  
3. To remove the wick  
assembly, lift it straight  
up and out of the  
moistener as shown in  
the accompanying illustration.  
4. If the wick gets dirty, replace the entire wick assembly  
with a new one. Remove it as described in step 3 above;  
install the new one as shown. Make sure the new wick  
assembly is all the way down against the deck.  
SV60941 Rev. B  
8-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8 • Supplies and Options  
The DataLink (Electronic Interface Unit or EIU) is an expan-  
DataLink  
sion module that's permanently mounted to the back of your  
postage meter. It increases account capacity from 10 to 100  
and provides three communications ports, allowing you to  
connect your meter to a variety of external devices. These  
include a Pitney  
(Electronic  
Interface Unit)  
(B700 Only)  
Bowes Electronic  
Scale, a modem  
for one-button  
postage refill, and  
an IBM-compatible  
personal computer  
U
L
or serial printer.  
Complete operat-  
ing instructions are  
furnished with your  
DataLink.  
For options and supplies, visit our web site: www.pb.com  
Go to My Account Access and select Supplies Online.  
Select B700 Post PerfectTM.  
Ordering  
Supplies and  
Options  
You may also call the PB Supply Lineat 1-800-243-7824.  
B700 and B702  
Ribbon Cassette  
Item  
767-0  
Postage Tape Sheets  
612-7  
Standard or Custom Advertising Slogans  
Call PB Supply  
LineTM  
B700 Only  
E-Z Seal® Sealing Solution (pint)  
Item  
601-0  
Wick Assembly  
621-7  
Postal Inscriptions  
See Appendix  
8-6  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix  
This appendix lists the postal inscriptions available  
for your postage meter.  
Meter Inscriptions............................................ A-2  
SV60941 Rev. B  
A-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix  
The table below lists the postal inscriptions available for your  
meter. Use the order number when you place your order with  
the PB Supply Line; use the inscription code number to  
select the inscription after it's been activated. See page 8-4  
for ordering instructions and page 4-14 for activation instruc-  
tions.  
Meter  
Inscriptions  
Available Inscriptions  
Order  
Number  
Code  
Number  
Inscription  
049-7  
063-7  
057-7  
079-7  
073-7  
069-7  
071-7  
077-7  
013-7  
026-7  
070-7  
017-7  
075-7  
038-7  
102-7  
105-7  
099-7  
054-7  
074-7  
080-7  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
Additional Presort Postage Paid  
Bound Printed Matter  
Bound Printed Matter Bulk Rate  
Bulk Rate  
Bulk Rate 5-Digit ZIP+4  
Bulk Rate Carrier Route Presort  
Bulk Rate ZIP+4  
Bulk Rate ZIP+4 Barcoded  
Carrier Route Presort  
First Class  
First Class Carrier Route Presort  
First Class Mail Enclosed  
First Class ZIP+4 Barcoded  
First Class ZIP+4 Presort  
Fourth Class Bulk Rate  
Fourth Class DBMC  
International Priority Mail  
Library Rate  
Nonprofit 5-digit ZIP+4  
Nonprofit Org  
014-7,  
068-7  
Nonprofit Org Carrier Route Presort  
A-2  
SV60941 Rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix  
Available Inscriptions  
Inscription  
Order  
Number  
Code  
Number  
31  
072-7  
076-7  
042-7  
101-7  
067-7  
104-7  
Nonprofit ZIP+4  
32  
Nonprofit ZIP+4 Barcoded  
Par Avion/Air Mail  
33  
34  
Pound Rate Paid Via Permit  
Presorted First Class  
35  
36  
Presorted First Class ZIP+4  
Barcoded  
093-7  
010-7  
098-7  
011-7  
103-7  
018-7  
050-7  
052-7  
060-7  
061-7  
096-7  
078-7  
097-7  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
Presorted Priority Mail  
Presorted Special Fourth Class Rate  
Printed Matter  
Printed Matter Books  
Printed Matter Catalogs  
Printed Matter Par Avion  
Printed Matter Second Class  
Printed Matter Sheet Music  
Priority Mail  
Small Packet  
Special Fourth Class Rate  
Third Class  
US International Air Mail Postage Paid/  
Par Avion  
065-7  
066-7  
50  
51  
ZIP+4  
ZIP+4 Presort  
SV60941 Rev. B  
A-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1 Elmcroft Road  
Stamford, Connecticut 06926-0700  
For Service or Supplies  
Customer Support: 1-800-522-0020  
Product Name: B700, B702  
Model Number: B700, B702  
PB Form SV60941 Rev. B 05/04  
©2004 Pitney Bowes Inc.  
All Rights Reserved  
Printed in the USA  
Printed on recyclable paper  
*sv60941Revb*  
Download from Www.Somanuals.com. All Manuals Search And Download.  

PDP Switch HDMI Smart Switch Universal User Manual
Philips Clock Radio AJ 3130 User Manual
Philips DVD Player DCR 2020 User Manual
Philips Headphones PSC 703 User Manual
Philips Home Safety Product SFL5261 User Manual
Phoenix Gold Car Amplifier SD13001 User Manual
Pioneer Car Video System DVH 3950MP User Manual
Polaroid Digital Camera Flash 640 SE User Manual
Poulan Snow Blower 415242 User Manual
PYLE Audio Clock Radio PICL34 User Manual