Philips Work Light P 2220 E User Manual

®
Ceramalux High Pressure Sodium Lamps  
Energy efficiency and long life  
Comfort High Pressure Sodium  
For improved color rendering.  
RetroLux High Pressure Sodium  
Replace MercuryVapor with energy efficient  
HPS; operates on mercury vapor ballast.  
Instant Restrike  
High Pressure Sodium  
Dual arc-tube delivers 40,000 hours rated  
average life vs. 24,000 hours rated average  
life for standard HPS lamps. Extra arc-tube  
provides light instantly after momentary  
power interruption.  
®
ALTO High Pressure Sodium  
1
Passes EPA’sTCLP test for non-hazardous waste.  
Ideal for roadway lighting,  
warehouse lighting, security lighting,  
and industrial applications  
®
MasterColor HPS-Retro White  
Optimized to operate on a high pressure  
sodium ballast. Replace yellow light with  
crisp, bright white light with just a simple twist!  
1) The TCLP is the US EPA’s Toxicity Characteristic Leaching Procedure.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instant Restrike High Pressure Sodium Lamps  
Extra arc tube offers light instantly after momentary power interruption  
and will provide 80% light output within 1–2 minutes  
For applications where instant restrike is not required,  
rated average life is 40,000 hours  
Operates on standard HPS ballasts and auxiliary equipment  
Electrical,Technical and Ordering Data (Subject to change without notice)  
ANSI  
Code/  
Ballast Ref.  
Std.  
Pkg.  
Qty.  
Rated  
Approx.  
Initial  
Lumens  
Approx.  
Mean  
Lumens  
Product  
Number  
Ordering  
Code  
Nom.  
Watts Bulb  
LCL  
(In.)  
MOL  
(In.)  
Avg. Life  
CCT  
(K)  
1
2
3
Base  
Description  
Hrs.  
CRI  
35467-0  
26541-3  
26560-3  
26561-1  
37717-6  
37688-9  
20412-3  
C50S68/2  
C70S62/2  
50  
70  
ED-23 12  
Mog.  
Mog.  
Mog.  
Mog.  
Mog.  
Mog.  
Mog.  
S68  
S62  
S54  
S55  
S50  
S51  
S52  
12  
12  
12  
12  
12  
12  
6
G, S (4, 6, 9, 12, 14)  
G, S (4, 6, 9, 12, 14)  
G, S (4, 6, 9, 12, 14)  
G, S (4, 6, 9, 12, 14)  
G, S (4, 6, 9, 12, 14)  
G, S (4, 6, 9, 12, 14)  
G, S (4, 6, 9, 12, 14)  
5
5
5
5
7 34  
24,000+  
24,000+  
24,000+  
24,000+ 15,600  
24,000+ 27,500  
24,000+ 49,000  
24,000+ 140,000  
3800  
5600  
9100  
3450  
5050  
8190  
14,000  
24,750  
44,000  
126,000  
21  
21  
21  
21  
21  
21  
21  
2100  
2100  
2100  
2100  
2100  
2100  
2100  
ED-23 12  
ED-23 12  
ED-23 12  
ED-18  
7 34  
C100S54/2  
C150S55/2  
C250S50/2  
C400S51/2  
C1000S52/2  
100  
150  
250  
400  
1000  
7 34  
7 34  
5 34  
5 34  
8 34  
9 34  
ED-18  
E-25  
9 34  
15 116  
See previous page for Warnings, Cautions and Operating Instructions  
®
Ceramalux RetroLux High Pressure Sodium Lamps  
For operation on all mercury vapor and metal halide ballasts of similar wattage  
150W retrofits 175 watt mercury vapor or metal halide  
220W retrofits 250 watt mercury vapor or metal halide  
360W retrofits 400 watt mercury vapor or metal halide  
Electrical,Technical and Ordering Data (Subject to change without notice)  
ANSI  
Code/  
Ballast Ref.  
Std.  
Pkg.  
Qty.  
Rated  
Approx.  
Approx.  
Mean  
Lumens  
Product  
Number  
Ordering  
Code  
Nom.  
Watts Bulb  
LCL  
(In.)  
MOL  
(In.)  
Avg. Life  
Initial  
CCT  
(K)  
1
2
3
Base  
Description  
Hrs.  
Lumens  
CRI  
39194-6  
39195-3  
39196-1  
C150S63/Retrolux  
C220S65/Retrolux  
C360S64/Retrolux  
150  
220  
360  
BT-28  
BT-28  
BT-37  
Mog.  
Mog.  
Mog.  
S63  
S65  
S64  
12  
12  
6
G, S (12, $)  
G, S (12, $)  
G, S (12, $)  
5 964  
5 964  
7 18  
8 516  
24,000  
24,000  
24,000  
15,000  
25,000  
45,000  
13,500  
22,500  
40,500  
25  
25  
25  
2100  
2100  
2100  
8 516  
11 12  
®
WARNINGS, CAUTIONS AND OPERATING INSTRUCTIONS for Ceramalux RetroLux High Pressure Sodium Lamps  
Warnings, Cautions and Operating Instructions  
If a lamp bulb support is used, be sure to insulate the support  
electrically to avoid possible decomposition of the bulb glass.  
Do not scratch the bulb or subject it to pressure, as it could  
fail violently. If the outer bulb is broken, turn off the lamp and  
replace it promptly.  
Do not use this lamp in a fixture which redirects a substantial  
portion of the energy toward the arc tube and its immediate  
vicinity, as this may lead to very early lamp failure.  
CAUTION: Electric discharge lamp—Use only with proper  
circuits and auxiliary equipment designed to produce  
established electrical values for this lamp. Operating the lamp  
improperly may result in damage to equipment or personal  
injury, for which the lamp manufacturer does not assume  
any responsibility.  
NOTICE: For total supply load, add auxiliary (ballast) watts  
to lamp watts.  
The arc tube of this lamp contains sodium and mercury. Use  
appropriate care in disposal. Protect lamp base, socket and wiring  
against moisture, corrosive atmospheres and excessive heat.  
®
FOOTNOTES for Ceramalux High Pressure Sodium Lamps  
1) Rated average life is the life obtained, on the average,  
from large representative groups of lamps in laboratory  
tests under controlled conditions at 10 or more operating  
hours per start. It is based on survival of at least 50% of  
the lamps and allows for individual lamps or groups of  
lamps to vary considerably from the average. For lamps  
with a rated average life of 24,000 hours, life is based  
on survival of 67% of the lamps.  
5) Electrically insulated support for bulb may be  
required, especially in horizontal and nearly horizontal  
operating positions.  
9) For use in fixtures which do not redirect a substantial  
portion of the energy toward the arc tube; otherwise  
very early failure is anticipated.  
6) Fixtures should be designed so that sockets and wiring  
withstand starting pulse up to 5000 volts for 1000 watts  
and WHITE SON® types and 4000 volts for other sizes.  
10) Operates at rated output on ANSI 400W S145 ballasts.  
11) UV filtered design (FadeBlock).  
12) Heat resisting glass bulb.  
7) C150S55 and C150S56 lamps are not electrically  
interchangeable. Different ballasts are required for the  
proper operation of each lamp type. ANSI type S55  
ballast is for the 55-volt (normal) lamp and the ANSI  
type S56 ballast is for the 100 volt (nominal) lamp.  
13) PAR-38 (one piece)  
2) Approximate lumen values listed are for vertical  
operation of the lamp.  
14) Nickel plated brass base.  
This product utilizes ALTO® LampTechnology.ALTO  
products pass the US EPA'sToxicity Characteristic Leaching  
Procedure (TCLP) for non-hazardous waste status.  
3) Approximate lumen output at 40% of lamp rated average life.  
4) Follow fixture manufacturer’ recommendations regarding  
proximity of ballast to bulb.  
8) This lamp should be shielded from moisture to  
prevent breakage.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Philips Lighting Company  
200 Franklin Square Drive  
P. O. Box 6800  
Somerset, NJ 08875-6800  
1-800-555-0050  
Philips Lighting  
281 Hillmount Road  
Markham, Ontario  
Canada L6C 2S3  
1-800-555-0050  
A Division of Philips Electronics North America Corporation  
A Division of Philips Electronics Ltd.  
Updated 8/04  
P-2220-E  
®
MasterColor Ceramic Metal Halide HPS-Retro White  
MasterColor technology optimized to operate in existing HPS fixtures,  
which means a simple, twist-of-the-wrist conversion  
Improved work environment (crisp white light vs. yellow light)  
Better for the environment:TCLP -compliant  
Replace yellow light with white light with just a simple twist!  
For operation on HPS ballasts; 85% lumen maintenance  
No shut off required in 24-hour-a-day/7-day-a-week operations  
(relamp fixtures at or before the end of rated life)  
Electrical,Technical and Ordering Data (Subject to change without notice)  
ANSI  
Code/  
Std.  
Pkg.  
Description  
Rated  
Approx.  
Initial  
Lumens  
Approx.  
Mean  
Lumens  
Product  
Number  
Ordering  
Code  
Nom.  
Watts Bulb  
LCL  
(In.)  
MOL  
(In.)  
Avg. Life  
CCT  
(K)  
1
2
3
Base Ballast Ref. Qty.  
Hrs.  
CRI  
13093-0  
13094-8  
CDM250S50/V/O/4K/ALTO 250  
CDM400S51/V/O/4K/ALTO 400  
ED-18 Mog. M168/O  
ED-18 Mog. M169/O  
12  
12  
G, Clear,Vertical 15º (4, 5, 6)  
G, Clear,Vertical 15º (4, 5, 6)  
5 34  
9 34  
20,000  
20,000  
22,500  
34,000  
19,125  
28,900  
85  
85  
4000  
4000  
5 34  
9 34  
®
WARNINGS, CAUTIONS AND OPERATING INSTRUCTIONS for Protected MasterColor Ceramic Metal Halide  
HPS-RetroWhite Lamps ED-18 (Vertical Burn 15º, Open or Enclosed Fixtures)  
Warnings, Cautions and Operating Instructions  
These lamps are designed to retain all the glass  
particles should an arc tube rupture occur.The  
following operating instructions are recommended  
to minimize these occurrences.  
3. Use only auxiliary equipment meeting Philips and/or  
ANSI standards. Use within voltage limits recommended  
by ballast manufacturer.  
“WARNING: These lamps can cause serious skin  
Rburn and eye inflammation from short wave ultraviolet  
radiation if outer envelope of the lamp is broken or  
punctured. Do not use where people will remain for more  
than a few minutes unless adequate shielding or other safety  
precautions are used. Certain lamps that will automatically  
extinguish when the outer envelope is broken or punctured  
are commercially available.”This lamp complies with FDA  
radiation performance standard 21 CFR subchapter J.  
(USA:21CFR 1040.30 Canada:SOR/DORS/80-381)  
A. Operate lamp only within specified limits of operation.  
B. For total supply load refer to ballast manufacturers  
electrical data.  
RELAMP FIXTURES AT OR BEFORETHE END OF  
RATED LIFE.Allowing lamps to operate until they  
fail is not advised and may increase the possibility of  
inner arc tube rupture.  
4. Periodically inspect the outer envelope. Replace any  
lamps that show scratches, cracks or damage.  
This lamp contains an arc tube with a filling gas  
containing Kr-85 and is distributed by Philips  
Lighting Company, a division of Philips Electronics  
North America Corporation, Somerset, New  
Jersey, 08875.  
5. If a lamp bulb support is used, be sure to insulate the  
support electrically to avoid possible decomposition of  
the bulb glass.  
If the outer bulb is broken or punctured, turn off  
at once and replace the lamp to avoid possible  
injury from hazardous short wave ultraviolet  
radiation. Do not scratch the outer bulb or subject  
it to pressure as this could cause the outer bulb to  
crack or shatter.A partial vacuum in the outer  
bulb may cause glass to fly if the envelope is struck.  
6. Protect lamp base, socket and wiring against moisture,  
corrosive atmospheres and excessive heat.  
CAUTION: TO REDUCETHE RISK OF PERSONAL  
INJURY, PROPERTY DAMAGE, BURNS AND FIRE  
RESULTING FROM AN ARC-TUBE RUPTURETHE  
FOLLOWING LAMP OPERATING INSTRUCTIONS  
MUST BE FOLLOWED:  
7.Time should be allowed for lamps to stabilize in color  
when turned on for the first time.This may require  
several hours of operation, with more than one start.  
Lamp color is also subject to change under conditions  
of excess vibration or shock and color appearance may  
vary between individual lamps.  
WARNING: The arc-tube of metal halide lamps  
are designed to operate under high pressure and at  
temperatures up to 1000º C and can unexpectedly rupture  
due to internal or external factors such as a ballast failure or  
misapplication. If the arc-tube ruptures for any reason, the  
outer bulb may break and pieces of extremely hot glass  
might be discharged into the surrounding environment. If  
such a rupture were to happen, THERE IS A RISK OF  
PERSONAL INJURY, PROPERTY DAMAGE,  
BURNS AND FIRE.  
LAMP OPERATING INSTRUCTIONS:  
1. RELAMP FIXTURES AT OR BEFORETHE END OF  
RATED LIFE. Allowing lamps to operate until they fail is  
not advised and may increase the possibility of inner arc  
tube rupture.  
8. Lamps may require 10 to 20 minutes to re-light if there  
is a power interruption.  
9.Take care in handling and disposing of lamps. If an arc  
tube is broken, avoid skin contact with any of the  
contents or fragments.  
2. Before lamp installation/replacement, shut power off and  
allow lamp and fixture to cool to avoid electrical shock  
and potential burn hazards.  
®
®
FOOTNOTES for MasterColor Ceramic Metal Halide HPS-Retro White Lamps  
1) Rated average life is the life obtained, on the average,  
from large representative groups of lamps in laboratory  
tests under controlled conditions at 10 or more operat-  
ing hours per start. It is based on survival of at least 50%  
of the lamps and allows for individual lamps or groups of  
lamps to vary considerably from the average.  
2) Approximate lumen values listed are for vertical  
operation of the lamp.  
6) MasterColor® Metal Halide Lamps are not recommended  
for use on dimmers and are not warranted if used on  
dimmer systems.  
3) Approximate lumen output at 40% of lamp rated average life.  
This product utilizes ALTO® LampTechnology.ALTO  
products pass the US EPA'sToxicity Characteristic Leaching  
Procedure (TCLP) for non-hazardous waste status.  
4) Performance may not be satisfactory unless operated  
within specified operating positions.  
5) Heat resisting glass bulb.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Peavey Musical Instrument Amplifier TKO User Manual
Perle Systems Network Router MDC User Manual
Philips Digital Camera SPC900NC 00 User Manual
Philips DVR HTR5204 User Manual
Philips Flat Panel Television PT9008 User Manual
Philips MP3 Docking Station DC1050 12 User Manual
Philips Satellite Radio DLV92009 User Manual
Philips Stereo System MCM309R User Manual
Philips Work Light IS LPW User Manual
Pinnacle Speakers Network Router Lightning 1000 User Manual