Perle Systems Network Card C 110 XXXXX User Manual

Perle 10/100 Ethernet  
Media Converter  
Module  
Installation Guide  
C-110-XXXXX  
Unmanaged Module  
Managed Module  
CM-110-XXXXX  
P/N 5500307-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
The module comes equipped with a bank of DIP switches and jumpers  
for setting configuration.  
The default dip switch settings (all switches in the UP position) and  
default jumper settings will work for most installations.  
The following steps are used to configure the Perle 10/100 Ethernet  
Media Converter Module:  
1. Set the Auto-MDIX jumper (optional).  
2. Set the Auto-Config jumper (CM-110 only) (optional)  
3. Set the DIP switch settings (optional).  
4. Insert the Media Converter Module into the Chassis.  
5. Connect the fiber cable.  
6. Connect the copper cable.  
Auto-MDIX Jumper  
Note: The factory settings for Auto-MDIX will work for most  
installations, but if there is a need to modify the settings, follow the  
procedure below.  
The AUTO-MDIX jumper (J5) is located on the upper edge, at the  
midpoint of the module (see diagram below for labelling).. By covering  
or strapping pins 2 and 3(AUTO), the C-110 and CM-110 will  
automatically detect the Ethernet cable’s polarity and configure itself  
as either an MDI or an MDIX device. By covering or strapping pins 1  
and 2(MDIX), the C-110 and CM-110 will operate as an MDIX device  
Removing the strapping is the same as AUTO.  
NOTE: The default jumper setting is AUTO  
Perle 10/100 Media Converter Module – Installation Guide  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Auto-Config Jumper (CM-110 only)  
The Auto-Config jumper (J6) is located just below the Auto-MDIX  
jumper (see above). Refer to the diagram below for labelling. This  
jumper only applies to CM-110 modules.  
Strapping pins 1 and 2 of the jumper will set the module in SW mode  
and strapping pins 2 and 3 will set it in Auto Config mode.  
Auto: When set to Auto the module will, at power-up, check its  
internal flash memory to see if configuration information has been  
downloaded to it from a management module. If so it will use this as  
its running configuration. If there is no configuration in flash it will read  
the settings of the DIP switches and use those as its running  
configuration.  
SW: When set to SW (Switch), the module will, at power-up, read the  
settings of the DIP Switches and use those as its running  
configuration. It will ignore any configuration information in its flash  
memory.  
NOTE: The default jumper setting is Auto  
Perle 10/100 Media Converter Module – Installation Guide  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
DIP Switches  
DIP Switch Settings  
Auto Negotiation (Switch 1)  
Switch Position Mode  
Up (default)  
Down  
Auto  
Off  
Note: Auto negotiation should only be turned off, if the copper link  
partner does not support Auto Negotiation or fixed settings are  
required by the copper link partner.  
Auto: In this mode of operation the Media Converter Module will  
negotiate Ethernet parameters on the copper connection. This will  
ensure that the most optimal connection parameters will be used. If  
the copper link partner does not support Auto negotiation, the Media  
Converter Module will parallel detect to 10 or 100 Mbps and force  
Half Duplex mode as per IEEE specifications.  
Off: When the Auto Negotiation switch is set to the OFF position, the  
Media Converter Module will not negotiate the Ethernet parameters  
with the copper link partner. The parameters used by the Media  
Perle 10/100 Media Converter Module – Installation Guide  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Converter Module will be determined by the Duplex (switch 4) and  
Speed (switch 5) dip switch settings.  
Link Mode (Switch 2)  
Switch Position Mode  
Up (default)  
Down  
Link Pass-Through Mode  
Standard Mode  
Link Pass-Through: In this mode, the link state on one connection is  
directly reflected through the Media Converter Module to the other  
connection. If the link is lost on one of the connections, then the other  
link will be brought down.  
With Media Converters on both ends of the fiber link and both setup  
for Link Pass-Through, a loss of copper link on the far end device will  
propagate through both Converters and will result in a loss of copper  
link at the near end device. This would, in effect, resemble a direct  
copper connection  
Standard Mode: In this mode, the links on the fiber and copper sides  
can be brought up and down independently of each other. A loss of  
link on either the fiber or copper port can occur without affecting the  
other connection.  
Far End Fault (Switch 3)  
Switch Position Mode  
Up (default)  
Down  
Enabled  
Disabled  
Enabled: If the Media Converter Module detects a loss of receive  
fiber signal, it will transmit a FEF signal to the remote Media  
Converter. This, in effect, notifies the fiber link partner that an error  
condition exists on the fiber connection.  
If the remote Media Converter is set up for Far End Fault (FEF) and  
the local Media Converter is set up with Link Pass-Through, a loss of  
Perle 10/100 Media Converter Module – Installation Guide  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
fiber link on either the transmit or receive line will be passed through  
to the local copper connection thus notifying the connected device.  
If the Media Converter has been set to Link Pass-Through mode, the  
effect will be the same as FEF, since the link loss on the fiber receiver  
will result in bringing down the copper link, which will in turn cause the  
transmit fiber link to be brought down.  
Note: If it is required to either generate or detect the FEF signal, then  
the FEF switch needs to be set.  
Disabled: The Media Converter Module will not monitor for or  
generate Far End Fault.  
The following diagram is an illustration of the operation of this feature.  
(A) – Remote Media Converter setup for Far End Fault Enabled, Auto  
Negotiation – OFF and Link Mode – Standard.  
(B) – Local Media Converter setup for Far End Fault - Enabled, Link  
Pass-Through - On and Auto Negotiation - OFF  
1 – (A) Loses fiber connection on its receiver.  
2 – (A) Sends FEF.  
3 – (B) Detects FEF signal and shuts down the fiber link.  
4 – (B) Drops link on copper connection because Link Pass-Through  
is configured.  
5 – (A) Link on copper connection is not affected because Link Mode  
is set to Standard.  
Perle 10/100 Media Converter Module – Installation Guide  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Duplex (copper) (Switch 4)  
Switch Position Mode  
Up (default)  
Down  
Full  
Half  
Note: When Auto Negotiation (SW1) is set to Off, the Media  
Converter will use this Duplex setting for its copper connection.  
Up: The Media Converter Module will be set to Full Duplex mode.  
Down: The Media Converter Module will be set to Half Duplex mode.  
Speed (copper) (Switch 5)  
Switch Position Mode  
Up (default)  
Down  
100  
10  
Note: When Auto Negotiation (SW1) is set to Off, the Media  
Converter Module will use this Speed setting for its Ethernet copper  
connection.  
Up: The Media Converter will be fixed at 100 Mbps.  
Down: The Media Converter will be fixed at 10 Mbps.  
Perle 10/100 Media Converter Module – Installation Guide  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Duplex (fiber) (Switch 6)  
Switch Position Mode  
Up (default)  
Down  
Full  
Half  
Up: The Media Converter Module’s fiber link will be set to Full Duplex  
Mode.  
Down: The Media Converter Module’s fiber will be set to Half Duplex  
Mode.  
Loopback (Switch 7  
Switch Position Mode  
Up (default)  
Down  
Disabled  
Enabled  
Disabled: This is the setting for normal operation. The switch must be  
set to this position in order for data to pass through the Media  
Converter Module.  
Enabled: This is a test mode. All data received on the receive (RX)  
fiber connection is looped back to the transmit (TX) fiber connection.  
The state of the copper link is not relevant since no data is passed  
through to the copper side. This mode will override all other switch  
settings.  
Perle 10/100 Media Converter Module – Installation Guide  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing or Replacing Media Converter  
Modules  
Caution: Observe electrostatic discharge precautions when  
installing the Media Converter Module(s) into the Chassis.  
Failure to observe this caution could result in damage to the  
Media Converter Module(s) and /or chassis.  
The Perle Media Converter Modules can be installed in any  
available slot and in any order within the Chassis.  
Installing or Replacing a Media Converter Module  
1. Remove the Media Converter Module from its packaging.  
2. Using a cross-head screwdriver, remove the screw holding the  
face plate to the Chassis to reveal the slot opening.  
3. Set the jumpers and DIP switches on the Media Converter  
Module to the desired operating mode.  
4. Locate the top and bottom alignment guides inside the Chassis.  
5. Using the module alignment guides gently slide the module into  
the slot until it becomes flush with the front of the Chassis. Light  
pressure may be needed to seat the module. Do not force the  
module as you might cause some damage. If there is  
resistance, remove the module, check the module connector for  
damaged or incorrectly aligned pins, if there is no damage, retry  
module insertion.  
Perle 10/100 Media Converter Module – Installation Guide  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Tighten the captive retainer screw to ensure the Media  
Converter Module is locked in place.  
7. Remove the dust cap from the fiber connector and connect the  
fiber and copper cables.  
Removing Media Convert Modules  
1. Loosen the captive retainer screw on the front of the Media  
Converter Module and gently pull the Media Converter Module  
out.  
2. If not inserting a replacement, cover the opened slot with a face  
plate and secure the screw  
Installing the Duplex Fiber Cable  
Locate a 100Base-X compliant duplex (2 strands) fiber cable with  
appropriate connectors.  
Connect the fiber cables from the Media Converter Module to the  
other Media Converter/switch/fiber device ensuring that the RX and  
TX are reversed (crossed) at the opposite end.  
.
Installing the Simplex Fiber Cable  
Locate a 10/100Base-X compliant simplex (1 strand) fiber cable  
with appropriate connectors.  
Perle 10/100 Media Converter Module – Installation Guide  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connect the fiber cable from one Media Converter Module to the  
other Media Converter/switch/fiber device.  
Installing the Copper Cable  
Locate 10/100Base-T compliant copper cables with male, RJ-  
45 connectors installed at both ends.  
Connect the RJ-45 cable between the Perle Media Converter  
Module and the device.  
Note: The Perle Media Converter Module supports Auto-MDIX which  
allows a straight-through or cross-over Ethernet cable. See page 4 in  
this guide for jumper positions.  
Perle 10/100 Media Converter Module – Installation Guide  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
Status LED  
The Perle 10/100 Ethernet Media Converter Modules have six single color  
status LEDs located on the face plate of the module.  
PWR  
100 (copper speed)  
On – 100 Mbps  
Off – 10 Mbps  
On – Power is on; module is  
operating normally  
Blinking (slow) – The module is in  
Loopback mode.  
Blinking (fast) – The module has a  
hardware failure.  
FDF (fiber)  
FDC (copper)  
On – Full Duplex Mode.  
Off – Half Duplex Mode.  
On – Full Duplex Mode.  
Off – Half Duplex Mode.  
LKF (fiber )  
LKC (copper)  
On – The fiber link is present  
Off – No fiber link is present.  
Blinking (fast) – The fiber link is  
present and receiving data.  
On – The copper link is present.  
Off – No copper link present.  
Blinking (fast) – The copper link is  
present and receiving data.  
Perle 10/100 Media Converter Module – Installation Guide  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Other Features  
Auto-MDIX:  
Auto-MDIX (automatic medium-dependant interface crossover)  
detects the signalling on the 10/100BASE-T interface to determine  
the type of cable connected (straight-through or crossover) and  
automatically configures the connection.  
Error Recovery:  
In certain configurations, and under specific conditions where the  
Media Converter Module brings down a link to convey status, there is  
potential for a deadlock. Recovery is achieved by momentarily  
restoring the link to see if the original failure has been resolved. If it  
has not, the link will be forced down again, however if the original  
problem has been resolved, the link will be restored.  
Pause (IEEE 802.3xy):  
Integrated Pause signalling is an IEEE feature that temporarily  
suspends data transmission between two devices in the event that  
one of the devices becomes overwhelmed. The Perle Media  
Converter Module can generate and respond to Pause messages.  
Perle 10/100 Media Converter Module – Installation Guide  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting  
General  
Ensure that the Media Converter Module is securely seated in the  
chassis. The PWR LED should be on.  
Ensure both devices on either end of the fiber are compatible. If  
using a simplex fiber connection, ensure that you have both an  
Upstream (U) and Downstream (D) Media Converter.  
Ensure all cabling is of the correct type and is in good working  
order.  
For duplex fiber connections, ensure the RX and TX has been  
reversed between the two Media Converters.  
No connectivity  
If unable to get full connectivity with all DIP switches in the UP  
position, these methods are recommended for troubleshooting.  
Method 1  
1. If the Module is a CM-110, set the Auto-Config jumper (J6) to  
SW so that DIP switches are being read.  
2. Set the Link mode to Standard (SW2 – Down) on both Media  
Converters. Leave all other switches in the Up position.  
3. Connect the near end device to the copper connection. The LKC  
LED indicates good copper connection. If the LKC LED is not lit,  
then check the copper cable and the attached device. Repeat for  
the far end Media Converter.  
4. Connect the fiber cable to both Converters. The LKF LED  
indicates good fiber connection. If no LKF LED then check the  
fiber cabling.  
5. Return converters to desired configuration.  
Perle 10/100 Media Converter Module – Installation Guide  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Method 2:  
The fiber connection can also be verified by configuring the remote  
Media Converter for loopback mode. The LKF LEDs on both  
Media Converters should be lit. Data should pass through the local  
converter, over the fiber connection to the remote Media  
Converter. At the remote Media Converter, the data will be looped  
back and passed through the fiber, once again, to pass through  
the local converter to the copper link.  
Note: If troubleshooting a CM-110, setting the Auto-Config jumper  
(J6) to SW will ensure the DIP switches are being read.  
Perle 10/100 Media Converter Module – Installation Guide  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Specifications  
Power Input/Consumption  
Operating Temperature:  
Storage Temperature:  
Operating Humidity:  
Storage Humidity:  
Operating Altitude:  
MTBF: (C-110)  
12V DC / 2.1 W  
0 °C to 50 °C (32 °F to 122 °F)  
25 °C to 70 °C (-13 °F to 158 °F)  
-
5% to 90% non-condensing  
5% to 95% non-condensing  
Up to 3,048 m (10,000 ft)  
577,872 hours  
(CM-110)  
561,817 hours  
Fiber Optic Specifications:  
Wavelength  
(nm)  
TX Power  
(dB)  
RX Power  
(dB)  
Budget  
(dB)  
Model  
Mode  
MM  
MM  
MM  
SM  
SM  
SM  
SM  
SM  
SM  
SM  
SM  
SM  
SM  
C-110-M2SC2  
CM-110-M2SC2  
TX: 1310  
RX: 1310  
Min: -20  
Max: -12  
Min: -31  
Max: -14  
11  
11  
10  
14  
17  
19  
29  
29  
29  
29  
29  
29  
35  
C-110-M2ST2  
CM-110-M2ST2  
TX: 1310  
RX: 1310  
Min: -20  
Max: -12  
Min: -31  
Max: -14  
C-110-M2LC2  
CM-110-M2LC2  
TX: 1310  
RX: 1310  
Min: -20  
Max: -12  
Min: -30  
Max: -14  
C-110-S2SC20  
CM-110-S2SC20  
TX: 1310  
RX: 1310  
Min: -18  
Max: -7  
Min: -32  
Max: -3  
C-110-S2ST20  
CM-110-S2ST20  
TX: 1310  
RX: 1310  
Min: -15  
Max: -8  
Min: -32  
Max: -3  
C-110-S2LC20  
CM-110-S2LC20  
TX: 1310  
RX :1310  
Min: -15  
Max: 0  
Min: -34  
Max: -5  
C-110-S2SC40  
CM-110-S2SC40  
TX: 1310  
RX :1310  
Min: -5  
Max: 0  
Min: -34  
Max: -3  
C-110-S2ST40  
CM-110-S2T40  
TX: 1310  
RX :1310  
Min: -5  
Max: 0  
Min: -34  
Max: -3  
C-110-S2LC40  
CM-110-S2LC40  
TX: 1310  
RX :1310  
Min: -5  
Max: 0  
Min: -34  
Max: -3  
C-110-S2SC80  
CM-110-S2SC80  
TX: 1550  
RX: 1550  
Min: -5  
Max: 0  
Min: -34  
Max: -3  
C-110-S2ST80  
CM-110-S2ST80  
TX: 1550  
RX: 1550  
Min: -5  
Max: 5  
Min: -34  
Max: -3  
C-110-S2LC80  
CM-110-S2LC80  
TX: 1550  
RX: 1550  
Min: -5  
Max: 0  
Min: -34  
Max: -3  
C-110-S2SC120  
CM-110-S2SC120  
TX: 1550  
RX: 1550  
Min:  
0
Min: -35  
Max: -3  
Max: 5  
Perle 10/100 Media Converter Module – Installation Guide  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C-110-S2ST120  
CM-110-S2ST120  
TX: 1550  
RX: 1550  
Min:  
Max: 5  
Min:  
0
Min: -35  
Max: 0  
SM  
SM  
SM  
SM  
SM  
SM  
35  
35  
18  
18  
25  
25  
C-110-S2LC120  
CM-110-S2LC120  
TX: 1550  
RX: 1550  
0
Min: -35  
Max: -3  
Max: 5  
C-110-S1SC20U  
CM-110-S1SC20U  
TX: 1310  
RX: 1550  
Min: -14  
Max: -8  
Min: -32  
Max: -3  
C-110-S1SC20D  
CM-110-S1SC20D  
TX: 1550  
RX:1310  
Min: -14  
Max: -8  
Min: -32  
Max: -3  
C-110-S1SC40U  
CM-110-S1SC40U  
TX: 1310  
RX:1550  
Min: -8  
Max: -3  
Min: -33  
Max: -3  
C-110-S1SC40D  
CM-110-S1SC40D  
TX: 1550  
RX:1310  
Min: -8  
Max: -3  
Min: -33  
Max: -3  
Fiber Cabling Requirements:  
MM:  
50/125 microns or  
62.5/125 microns  
9/125 microns  
SM:  
Ethernet Copper Cabling Requirements:  
Category 5 UTP or STP  
24-22 AWG  
Straight through or Ethernet crossover  
Note: Please refer the product page on the Perle website for the most  
up to date list of models and specifications.  
Perle 10/100 Media Converter Module – Installation Guide  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Compliance Information  
FCC  
This product has been found to comply with the limits for a Class A digital device,  
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable  
protection against harmful interference when the equipment is operated in a  
commercial environment. This equipment generates, uses, and can radiate radio  
frequency energy and, if not installed and used in accordance with the instructions in  
this Guide, may cause harmful interference to radio communications. Operation of this  
equipment in a residential area is likely to cause harmful interference, in which case the  
user will be required to correct the interference at his/her own expense.  
EN 55022, Class A  
WARNING This is a Class A product. In a domestic environment this product may  
cause radio interference in which case the user may be required to take adequate  
measures.  
EN 55024, Class A  
Laser Safety – IEC 60825-1:2007  
This product meets Class I Laser safety requirements per IEC-60825-1:2007 standard  
and complies with FDA/CDRH 21 CFR1040.10 and 21 CFR1040.11.  
WARNING: Visible and invisible laser radiation may be present when cables are not  
connected. Do not stare into the beam or view the beam directly with optical  
instruments. Failure to observe this warning could result in an eye injury or blindness.  
WARNING: Use of controls, adjustments or the performance of procedures other than  
those specified herein may result in hazardous radiation exposure.  
 
Perle 10/100 Media Converter Module – Installation Guide  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warranty / Registration  
Perle’s standard Lifetime Warranty provides customers with return to  
factory repairs for Perle products that fail under the conditions of the  
warranty coverage. Details can be found at:  
Contacting Technical Support  
Contact information for the Perle Technical Assistance Center (PTAC)  
can be found at the link below. A Technical Support Query may be  
made via this web page.  
Copyright  
© 2010 Perle Systems Limited  
All rights reserved. No part of this document may be reproduced or used in any form without  
written permission from Perle Systems Limited.  
Perle 10/100 Media Converter Module – Installation Guide  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Philips Cassette Player AW 7960 User Manual
Philips CRT Television 14PT2219 User Manual
Philips Power Supply SJB2142 User Manual
Pinnacle Design TV Video Accessories TV19703 User Manual
Planet Technology Network Card WNL U550 User Manual
Planet Technology Network Router PL 201 UK US User Manual
Poulan Blower PPB3000B User Manual
Precision Power Stereo Amplifier PCX1250 User Manual
Pride Mobility Mobility Aid 3 Ultra User Manual
Pride Mobility Mobility Aid Mini Crosser User Manual