CM6800-48X8
Matrix Switcher/
Controller
Installation/
Operation Manual
C1515M-A (11/01)
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150
International Customers: Tel +1 (559) 292-1981 or FAX +1 (559) 348-1120
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION .....................................................................................................................63
OVERVIEW ...............................................................................................................63
OPERATING THE CM6800.......................................................................................63
SWITCH MONITORS........................................................................................63
SELECT CAMERAS .........................................................................................64
CONTROL RECEIVERS ...................................................................................64
OPERATE SEQUENCES..................................................................................65
RUN A MACRO .................................................................................................66
ACKNOWLEDGE AN ALARM...........................................................................67
CALL A PRESET ...............................................................................................67
CREATE AND RUN A PATTERN ......................................................................68
OPERATE AUXILIARIES/RELAYS ...................................................................68
CONTROL GENEX MULTIPLEXER AND GENEX MULTIPLEXER DISPLAYS ... 70
OPERATE SCANNING FUNCTIONS ...............................................................70
DETECT VIDEO LOSS .....................................................................................70
DEFINE ZONES ...............................................................................................70
APPENDIX ........................................................................................................................71
CM6800 DIP SWITCHES..........................................................................................71
MACRO COMMANDS ..............................................................................................72
ASCII OPERATING COMMANDS ............................................................................74
TROUBLESHOOTING ..............................................................................................77
GAINING INITIAL CONTROL ...........................................................................77
SOFTWARE RESET .........................................................................................77
SOLUTIONS TO COMMON PROBLEMS.........................................................78
KBD960/KBR960 ICON/BUTTON LEGEND .............................................................79
GLOSSARY.......................................................................................................................80
SPECIFICATIONS.............................................................................................................84
REGULATORY NOTICES .................................................................................................86
WARRANTY AND RETURN INFORMATION....................................................................86
Pelco Manual C1515M-A (11/01)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
LIST OF ILLUSTRATIONS
Figure
Page
1
CM6800 Application ...........................................................................................7
2
3
4
5
6
7
8
9
Installing Rack Ears .......................................................................................... 11
Mounting the CM6800 Matrix Switcher/Controller ............................................ 11
CM6800 Video Inputs........................................................................................12
Connecting Terminated Video Sources .............................................................13
Connecting Looping Video Sources ..................................................................13
PTZ Control Connections ..................................................................................14
Connecting Monitors .........................................................................................15
Connecting Alarms ............................................................................................16
Communication Port Connections and RJ-45 Connector Pin-Outs ..................17
CM6800 Communication Port Connections and Options .................................19
Data Cable Plugged into Local Keyboard .........................................................20
Data Cables Plugged into COM 5 and 6 ...........................................................20
Remote Keyboards ...........................................................................................22
RJ-45 Cable Types............................................................................................23
Connecting a KBD960/KBR960 to the CM6800 ...............................................24
Connecting a Single ALM2064 Alarm Interface Unit .........................................25
Connecting a Single REL2064 Relay Interface Unit .........................................26
Connecting Multiple M Devices – Local Connection .........................................27
Connecting Multiple M Devices – Remote Connection .....................................28
PC Connection to DB9 Port ..............................................................................29
PC Connection to RJ-45 Port ............................................................................29
Connecting Genex Multiplexers ........................................................................30
Wiring the AUX 1 and 2 (Relay) Outputs ..........................................................31
Wiring the F3 (TTL) Output ...............................................................................32
CM6800 Time/Date Stamp on Monitor..............................................................33
CM6800 Color Bars ..........................................................................................35
CM6800 Password Screen ...............................................................................37
CM6800 Programming Main Menu ...................................................................37
Access the About CM6800 Screen ...................................................................40
Access the Keyboard to Monitor Access Screen ..............................................40
Access the Camera to Keyboard Access Screen .............................................41
Access the Camera to Monitor Access Screen .................................................41
Access the Internal or External Alarm Screen ..................................................45
Access the Video Loss Screen .........................................................................47
Access the Alarm Group Screen .......................................................................48
Access the Set Auxiliary Screen .......................................................................49
Access the Camera Screen ..............................................................................50
Access the Daily Timer Screen .........................................................................51
Access the Weekly Timer Screen .....................................................................52
Access the Special Timer Screen .....................................................................52
Access the Logical Camera Number Screen ....................................................53
Access the Macro Screen .................................................................................54
Macro Status View Screen ................................................................................55
Access the Monitor Screen ...............................................................................56
Access the Set Password Screen .....................................................................58
Access the Port Screen ....................................................................................59
Access the Priority Screen ................................................................................60
Access the Sequence Screen ...........................................................................61
Access the Scratchpad Sequence Screen ........................................................61
Access the Time and Date Screen ....................................................................62
CM6800 DIP Switches – Factory Default Settings ............................................71
DIP Switch Cover Plate .....................................................................................77
CM6800 DIP Switch 7 .......................................................................................77
Icon/Button Legend ...........................................................................................79
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
4
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
LIST OF TABLES
Table
Page
A
B
C
D
E
F
G
H
I
Video Coaxial Cable Requirements ..................................................................12
Communication Port Devices and Wiring .........................................................18
Default Port Settings .........................................................................................18
Keyboard Addresses: KBD100/200/300 Series Keyboards ..............................21
Switch Settings—KBD200/300 Keyboards Only ...............................................21
Default Port Settings .........................................................................................34
CM6800 DIP Switch Settings ............................................................................71
Macro Commands .............................................................................................72
Examples of ASCII Commands.........................................................................74
ASCII Commands .............................................................................................75
Solutions To Common Problems .......................................................................78
J
K
Pelco Manual C1515M-A (11/01)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFEGUARDS AND WARNINGS
1. Read, keep, and follow these instructions.
2. Heed all warnings.
3. There are no user-serviceable parts inside this unit. Only authorized service personnel
may open the unit.
4. Installation and servicing should only be done by qualified service personnel and
conform to all local codes.
5. WARNING: To reduce the risk of fire or electric shock, do not expose this unit to rain
or moisture if this unit is designed for indoor use only.
6. Unless this unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6 or 6P
enclosure, it is designed for indoor use only and it must not be installed where
exposed to rain or moisture.
7. Do not expose this unit to dripping or splashing. Do not place objects filled with liquids,
such as vases, on this unit.
8. Do not block any ventilation openings. Install in accordance with the manufacturer’s
instructions.
9. The installation method and materials should be capable of supporting four times the
weight of the unit and equipment.
10. Do not install near any heat source.
11. Only use attachments/accessories specified by the manufacturer.
12. Clean only with dry cloth.
13. Do not defeat the safety purpose of the polarized or grounding-type plug.
14. Protect the power cord from being walked on or pinched, particularly at plugs,
convenience receptacles, and the point where they exit from the unit.
15. Unplug this unit during lightning storms or when unused for long periods of time.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous
voltage constituting a risk of electric shock
is present within this unit.
C A U T I O N :
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
This symbol indicates that there are
important operating and maintenance
instructions in the literature accompanying
this unit.
Please thoroughly familiarize yourself with the information in this manual prior to installation
and operation.
FOR QUALIFIED SERVICE PERSONNEL ONLY
1. Only use replacement parts recommended by Pelco.
2. After replacement/repair of this unit’s electrical components, conduct a resistance
measurement between line and exposed parts to verify the exposed parts have not
been connected to line circuitry.
3. CAUTION: Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type.
Battery should only be replaced by authorized service personnel.
6
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
DESCRIPTION
Pelco’s CM6800 Matrix Switcher/Controller is a cross-point video matrix switcher. The
CM6800 provides switching and control for 48 video inputs and eight monitor outputs from
any one of up to 18 keyboards, PCs, and other devices. All 48 video inputs can be used to
control other devices, such as multiplexers. Forty inputs allow for looping to other devices.
The CM6800 can be controlled from a local or remote keyboard, used with a multiplexer to
display multiple camera views on a monitor, and programmed from a personal computer
using the CM6800-MGR software package. The CM6800 can also be controlled with ASCII
commands.
The CM6800 features menu-driven, password-protected programming. Programming can
also be done remotely, with the CM6800-MGR software package. Programming menus are
provided in six languages: English, French, German, Italian, Portuguese, and Spanish.
Multiple ports are provided on the CM6800 for pan/tilt/zoom (PTZ) control, keyboards, and
peripheral components. A single data line can accommodate various types of equipment,
such as external alarm interface units and relay boxes.
ESPRITô
KBD300
CC3500H-2
SPECTRAÆ
VIDEO TO
SWITCHER
KBD300
SPECTRAÆ
ALARM
1
2
3
4
5
6
7
8
HZ
COM
8
9
10
11
12
13
14
15
16
1
2
3
19
35
4
20
36
5
21
37
6
7
75
1
5
CONTROL
PTZ
2
3
4
6
7
8
A
T
+
T
-
R
+
R
T
+
T
R
+
R
B
-
-
-
24
40
25
41
45
26
42
46
27
43
47
28
44
48
29
1
30
2
31
3
32
4
17
33
18
34
22
38
23
39
OUT
F
3
1
2
COM
1
5
6
7
8
120/230~
50/60 HZ
25 WATTS
ALTERNATE SOURCE INPUTS
VIDEO OUTPUTS
PC
CAMCLOSUREô
SPOT MAN
AUX
VCR
IN COM OUT
ALARMS
N
NH
OCC
S
4
3
2
1
5
OUT
IN
6
110-240V 50/60 Hz
7
8
1
2
3
4
5
6
7
8
9
10 11121314 1516
SVHS
SVHS
GENEXÆ MULTIPLEXER
WALL
BLOCK
MONITOR
4
3
2
1
5
6
4
3
2
1
5
6
5
6
4
3
2
1
7
8
7
8
7
8
12 VAC
TRANSFORMER
CM9505UPS
KBD960
KBD100
KBD300
KBD200
Figure 1. CM6800 Application
Pelco Manual C1515M-A (11/01)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
KEYBOARDS
Up to 16 keyboards from the KBD100/200/300 Series and 2 keyboards from the KBD960/
KBR960 Series can be connected to the CM6800, allowing monitoring stations that share a
common monitor to each have a keyboard. Camera positioning can be programmed and
controlled from the KBD200/300 and KBD960/KBR960 Series keyboards. Keyboard types
can be mixed in a system. Refer to Associated Equipment for keyboard descriptions.
SEQUENCES, MACROS, PRESETS, PATTERNS, AND ZONES
Special programmed operations include sequences, macros, and camera control, such as
presets, patterns, and zones. All programming (except the scratchpad sequence) is
password-protected.
A sequence allows operators to see a routine of 72 camera views on any system monitor
over and over again. The sequence can be operated automatically or manually. The order
in which the camera views appear and the time each view remains can be programmed.
The CM6800 also provides a scratchpad sequence, which allows a sequence to be run
from an individual monitor. The scratchpad sequence can be accessed without entering the
password-protected programming menus.
A macro is a sequence of commands or steps. When a macro is run, the steps programmed
into that macro are performed. Macros can be operated automatically or manually. Automatic
operation can be based on specific times or dates.
The following operations are available only with positionable cameras:
A preset allows operators to direct a PTZ (camera positioning system) to move to a
predetermined scene on keyboard command or as a result of an alarm. In addition to
moving the camera, a descriptive title can appear on the screen. The number of
presets available is determined by the camera positioning system. (Presets are not
available with the KBD100 keyboard.)
With a pattern operators can program a camera positioning system to move around
its viewing area in a repeating pattern. The number and time length of patterns varies
with different positioning systems. (Patterns are not available with the KBD100
keyboard.)
A zone is a user-defined, physical location to which (1) a label is attached and (2) a
camera is associated. When the associated camera is panned through or remains
within this defined zone, the zone label appears on the monitor. (Zones are not
available with the KBD100 keyboard.)
INTERFACE CONTROL
The CM6800 interfaces with the following:
•
•
•
Coaxitron® standard mode (15-bit) and extended mode (32-bit) protocol receivers
Pelco’s D and P protocol receivers (RS-422)
Pelco’s M protocol devices (RS-485)
PARTIONING AND PRIORITY
The CM6800 provides four ways to partition your system:
•
•
•
Camera to Monitor: Cameras can be assigned to specific monitors for viewing.
Keyboard to Monitor: Keyboards can be assigned to control specific monitors.
Camera to Keyboard:
- Viewing: Keyboards can be assigned view-only access to specific cameras (no
PTZ control).
- Control: Keyboards can be assigned PTZ control and viewing access to specific
cameras.
The CM6800 provides eight levels of priority control. Each level defines the ability of a
keyboard to control a camera positioning system and to access programming screens.
8
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
ALARM INPUTS
The CM6800 can accommodate 136 alarm inputs.
Eight internal alarm inputs are provided on the rear panel of the matrix switcher/controller.
These internal alarm inputs are programmable to associate any camera to any input.
The CM6800 provides numerous alarm handling and display options. For example, alarms
can:
•
•
•
cause a system monitor display to switch automatically to the camera with the alarm.
activate patterns or go to presets.
operate auxiliary outputs.
Also, up to two ALM2064 Alarm Interface Units can be connected to the CM6800. Each
alarm interface unit can handle up to 64 alarms, for a total of 128 external alarms.
AUXILIARY OUTPUTS
Three internal auxiliary outputs are provided on the back of the CM6800. Two are relay
outputs, and one is an open collector (TTL) output. You can also connect up to two
REL2064 Relay Interface Units for a maximum capacity of 128 auxiliaries.
Auxiliary outputs are activated at the keyboard (except KBD100).
POWER, MOUNTING METHODS
The CM6800 operates on 120V or 230V, 50/60 Hz. The case mounts in three rack units
(5.25 inches or 13.34 cm) of vertical space in a universal mount, such as a 19-inch (48.26
cm) equipment bay, or to a wall or tabletop.
CONTINUOUS OPERATING DEVICE
The CM6800 is a self-contained video surveillance system designed specifically for use in
security applications. As such, the CM6800 is intended for continuous duty operation. Once
installed, there are no user or service technician items that require intervention which would
require the system to go off-line or have the power turned off under normal operation.
There are two methods for system programming: direct menu control and indirect control,
using a Windows®-based setup program supplied by Pelco. Both of these methods are
noninvasive and do not require the cycling of power in order for storage or execution of new
software settings. The communication ports use standard low voltage interfaces such as
RS-232, RS-422 and RS-485, and all connections and disconnections do not require
rebooting or power cycling. Video connections or changes of termination state do not
require rebooting or power cycling.
Pelco Manual C1515M-A (11/01)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
MODELS
CM6800-48X8
Matrix switcher/controller with 48 video inputs and 8 monitor outputs,
120/230V, 50/60 Hz
CM6800-48X8-X
Matrix switcher/controller with 48 video inputs and 8 monitor outputs,
120/230V, 50/60 Hz
ASSOCIATED EQUIPMENT
KBD100
KBD200
KBD300
Desktop keyboard with full switching and programming capabilities,
+12 VDC or 12V 50/60 Hz
Desktop keyboard with full switching and programming capabilities,
plus push-button control of PTZ functions, +12 VDC or 12V 50/60 Hz
Desktop keyboard with full switching and programming capabilities,
plus joystick control of PTZ functions, +12 VDC or 12V 50/60 Hz
KBD960
Full-function desktop variable-speed keyboard; 120V, 50/60 Hz
Same as KBD960, PAL-configured for 230V, 50/60 Hz operation
Full-function rack mount variable-speed keyboard; 120V, 50/60 Hz
Same as KBR960, PAL-configured for 230V, 50/60 Hz operation
KBD960-X
KBR960
KBR960-X
KBDKIT
Wiring kit for connecting KBD100, KBD200, and KBD300 keyboards to
remote keyboard port; includes two RJ-45 wall blocks and a
transformer to convert 120V, 60 Hz to 12V, 60 Hz for keyboard power
KBDKIT-X
Wiring kit for connecting KBD100, KBD200, and KBD300 keyboards to
remote keyboard port; includes two RJ-45 wall blocks and a
transformer to convert 230V, 50 Hz to 12V, 50 Hz for keyboard power
CM9505UPS
MX4000
Universal Power Supply for KBD960/KBR960 keyboards
Genex® Series Multiplexer; available in color or monochrome duplex,
and in color or monochrome simplex
CM9760-CDU-T
Code distribution unit; 16-channel RS-422 transmit only (transmit wire
and ground) distributor; primarily used for connecting up to 16 PTZ
receivers in a “star” or “home run” configuration
ALM2064
Alarm interface unit, provides alarm monitoring capabilities for up to 64
alarm inputs, 100-240V, 50/60 Hz
REL2064
Relay interface unit, provides 64 relays for operating peripheral
equipment, 100-240V, 50/60 Hz
CM9760-MDA
Master distribution amplifier with time, date, and title, 120V, 60 Hz
10
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
Unpack and inspect all parts carefully. The following parts are supplied:
1
4
4
1
4
1
4
CM6800 Switcher/Controller
10-32 x .750-inch pan head screws
.500” OD nylon washers
NOTE: There are no user-
serviceable parts inside this
unit. Only authorized service
personnel may open the
unit.
Power cord
6-foot (1.8 m) straight data cables with RJ-45 connectors
6-foot (1.8 m) reversed data cable with RJ-45 connectors
RJ-45 wall block terminals
MOUNTING
1. Select a suitable location for the CM6800. It occupies 5.25 inches (13.34 cm) of
vertical space, or three rack units (RUs), in a universal mount. The CM6800 must be
within 6 feet (1.8 m) of a suitable electrical outlet.
Follow proper installation practices and leave 1 RU above and below the
CM6800 for ventilation.
Do not connect the power until the installation is complete. Refer to the System
Start-Up section.
2. The CM6800 is shipped with the rack ears installed at the front. Reposition as needed
for your application. If the ears are not required, remove them.
POSITION BRACKETS FOR
RACK MOUNTING (REAR)
POSITION BRACKETS FOR
UNDER-TABLE MOUNTING
00624
POSITION BRACKETS FOR
RACK MOUNTING (FRONT)
NOTE: EACH CM6800 COMES
WITH 2 RACK EARS
POSITION BRACKETS FOR
FLUSH MOUNTING
(WALL AND TABLE TOP)
Figure 2. Installing Rack Ears
3. Use supplied pan head screws and washers to mount the CM6800 in a standard 19-
inch (48.26 cm) equipment rack or wood or sheet metal screws to mount against a flat
surface, according to your installation requirements.
00615
Figure 3. Mounting the CM6800 Matrix Switcher/Controller
Pelco Manual C1515M-A (11/01)
11
Download from Www.Somanuals.com. All Manuals Search And Download.
VIDEO SOURCES
The CM6800 offers 48 full-function video inputs which support Coaxitron PTZ control and
video loss detection. Forty video inputs, labeled 1 through 40, can be used for looping
video connections with terminating and unterminating switches on the back panel. The
eight alternate source inputs, labeled 41 through 48, are terminated inputs. They do not
have loop-through connectors or selectable termination switches, but otherwise they offer
the same functionality as video inputs 1 through 40.
All 48 video inputs also provide the ability to view and interface with other devices, such as
Genex multiplexers. If control of the device connected to the video input is required,
connect a data cable between the multiplexer and the CM6800. Refer to the Connecting
Genex Multiplexers section for instructions on connecting and controlling video from a
multiplexer.
00625
Figure 4. CM6800 Video Inputs
1. Connect video cables at the appropriate video input BNC receptacles on the back of
the CM6800. For best results, use crimp-on BNCs only. Do not use screw-on BNCs;
these typically do not provide adequate ground and signal connections.
Refer to Table A for video coaxial wiring requirements.
Table A. Video Coaxial Cable Requirements
Cable Type*
Maximum Distance
RG59/U
RG6/U
750 ft (229 m)
1,000 ft (305 m)
1,500 ft (457 m)
RG11/U
* Minimum cable requirements:
75 ohms impedance
All-copper center conductor
All-copper braided shield with 95% braid coverage
12
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
2. On video inputs 1 through 40, set the terminating switches according to your system
requirements. Video inputs 41 through 48 cannot be used for loop-through connections.
Terminating switches are used to terminate or unterminate the video input. The factory
default has the switches set in the terminated (75-ohm) position.
If you are connecting only a camera to an input, leave the switch in the terminated
position.
00626
Figure 5. Connecting Terminated Video Sources
If you are looping the input to another device, set the rear panel switch in the
unterminated (Hi-Z) position. Terminate at the final device.
NOTE: The end point of
any video cable run must be
terminated in 75 ohms.
00627
Figure 6. Connecting Looping Video Sources
Pelco Manual C1515M-A (11/01)
13
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTROL LINES
NOTE: D and P protocol
receivers cannot be mixed
on the same communication
port but you can use D on
one port and P on the other.
You cannot connect a Coaxitron camera to the PTZ-A or PTZ-B ports. If your video sources
are all controlled by Coaxitron, skip this section.
Connect camera control lines to receivers. If any of your video sources are using D or P
protocol via RS-422 communications, they will connect at the PTZ-A and PTZ-B connectors
on the back of the CM6800.
Daisy-chaining (going from one receiver to another) is recommended but not always possible.
A maximum of 16 receivers can be daisy-chained from each port. If more than 32 receivers
are required for your system, or if you do not want to daisy-chain the receiver connections,
use the CM9760-CDU-T. You can connect up to four CM9760-CDU-T units to the
CM6800-48X8.
NOTE: After completing
system installation and
power-up, you must config-
ure the CM6800 and the
camera/receiver. Refer to
the System Start-Up section.
00628
Figure 7. PTZ Control Connections
14
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
MONITORS
The CM6800 supports eight monitors.
1. Install monitors according to the instructions provided with them.
2. Connect the monitor cables at the appropriate video output BNC receptacles on the
back of the CM6800.
3. Terminate cables at the monitors. If you are looping to other devices, unterminate all
but the last device.
00629
Figure 8. Connecting Monitors
Pelco Manual C1515M-A (11/01)
15
Download from Www.Somanuals.com. All Manuals Search And Download.
ALARMS
The CM6800 provides numerous alarm handling options. Refer to the Programming section
for a detailed description.
1. Connect wires from the sensors to the respective alarm input points on the connectors
at the back of the CM6800. Each sensor requires two wires – one wire to the alarm
input terminal and a return wire to one of the ground terminals on the connector. The
CM6800 supports eight internal alarms.
Alarm sensors can be either N.O. (normally open) or N.C. (normally closed) contacts.
The CM6800 is set to N.O. as a factory default.
2. If your system requires more than eight alarms, connect an ALM2064 unit to the
system. Refer to the M Devices section.
00631
Figure 9. Connecting Alarms
16
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
CONNECTING DEVICES THROUGH THE COMMUNICATION PORTS
The CM6800 Matrix Switcher/Controller provides eight communication ports on the rear
panel for connecting peripheral components. You can connect a wide variety of devices,
such as keyboards, a personal computer (for either the CM6800 MGR package or ASCII
control), alarm and relay boxes, and multiplexers. Instructions are provided in this section
for the most commonly used connections.
NOTE: Connection instruc-
tions for other peripheral
devices, such as the
CM9760-MDA or
CM9760-CDU-T, are
provided as Pelco Technical
Tips, available from the
Pelco web site or from a
Technical Support represen-
tative (1-800-289-9100). For
more information, go to
Resources. Then select
Technical Tips.
The CM6800 communication ports are labeled COM 1 through 8. Port 1 is available either
as a DB9 connection, or as an RJ-45 connection. Ports 2 through 8 are RJ-45 connections.
In the programming menus these are referred to as serial ports 1 through 8.
COM PORTS 7, 8
RS-485 (PROGRAMMABLE
TO RS-232), RJ-45
PIN 1
PIN 8
RS-485 FUNCTION
1-----Rx+
RS-232 FUNCTION
1-----Rx
2-----Rx-
2-----NC
3-----NC
4-----NC
3-----NC
4-----NC
5-----GROUND
6-----NC
7-----Tx-
5-----GROUND
6-----NC
7-----NC
8-----Tx+
8-----Tx
COM PORT 1
RS-232,DB9
COM PORTS 1, 2
RS-232, RJ-45
COM PORT 3
M, RS-485, RJ-45
COM PORT 4
RS-485, RJ-45
COM PORTS 5, 6
RS-485, RJ-45
PIN 1
PIN 5
PIN 1
PIN 8
PIN 1
PIN 1
PIN 1
PIN 8
PIN 8
PIN 8
PIN 9
PIN 6
1-----NC
2-----Rx
3-----Tx
4-----NC
5-----GROUND
6-----NC
1-----Rx
1-----Rx+
2-----Rx-
3-----NC
4-----NC
5-----GROUND
6-----NC
1-----Rx+
2-----Rx-
3-----NC
1-----Rx+
2-----Rx-
3-----KBD 12V
4-----KBD GROUND
5-----GROUND
6-----NC
2-----NC
3-----NC
4-----NC
5-----GROUND
6-----NC
7-----NC
8-----Tx
4-----NC
5-----GROUND
6-----NC
7-----Tx-
7-----NC
8-----NC
7-----Tx-
8-----Tx+
7-----Tx-
8-----Tx+
8-----Tx+
9-----NC
NC = NO CONNECTION
Figure 10. Communication Port Connections and RJ-45 Connector Pin-Outs
Pelco Manual C1515M-A (11/01)
17
Download from Www.Somanuals.com. All Manuals Search And Download.
The communication ports are wired for either RS-232 or RS-485 (the wiring can be selected
for COM 7 and 8). Refer to the following tables for the CM6800 default communication port
settings. Some ports can be programmed for other devices; this will be done when you
program the CM6800.
Table B. Communication Port Devices and Wiring
Port
Default Device
Wiring
Programmable to Other Device(s)
COM 1
PC Setup – CM6800MGR program
RS-232
ASCII device
(accessible with a DB9
connection or an RJ-45
connection)
COM 2
COM 3
ASCII device
RS-232
RS-485
No
No
M devices — ALM2064, REL2064,
KBD960
COM 4
COM 5
Genex multiplexer
RS-485
CM9760-MDA, ASCII
No
Keyboard (direct powered) –
KBD100, 200, & 300
RS-485 plus power
COM 6
COM 7
COM 8
Keyboard (direct powered) –
KBD100, 200, & 300
RS-485 plus power
RS-232 or RS-485
RS-232 or RS-485
No
ASCII device
CM9760-MDA, keyboards
(KBD100, 200, & 300)
ASCII device
MDA, keyboards
(KBD100, 200, & 300)
Table C. Default Port Settings
NOTE: Refer to the
Programming section for
instructions on changing
Serial Port settings.
Port
Default Settings
COM 1
COM 2
COM 3
COM 4
COM 5, 6
COM 7, 8
MGR, RS-232, 56000 baud, no parity, 8 data bits, 1 stop bit
ASCII, RS-232, 9600 baud, no parity, 8 data bits, 1 stop bit
M, RS-485, 19200 baud, no parity, 8 data bits, 1 stop bit
MUX, RS-485, 9600 baud, odd parity, 8 data bits, 1 stop bit
KBD-300, RS-485, 9600 baud, odd parity, 8 data bits, 1 stop bit
ASCII, RS-485, 9600 baud, no parity, 8 data bits, 1 stop bit
18
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
COM 1
PC SETUP (RS-232)
USE DB9 CONNECTION
OR ALTERNATE RJ-45 CONNECTION
BOTH CANNOT BE USED SIMULTANEOUSLY
PC DB9 CONNECTION
RS-232 NULL MODEM CABLE
NOTE: TOTAL NUMBER OF
KBD100/200/300 SERIES
KEYBOARDS CONNECTED
TO THE CM6800 CANNOT
EXCEED 16
COM 5 & 6
LOCAL KEYBOARDS (RS-485)
KBD100/200/300 SERIES
MAX # OF DEVICES = 8
ALARM
1
2
3
4
5
6
7
8
COM
PC RJ-45 CONNECTION
1
5
CONTROL
PTZ
2
3
4
6
7
8
A
T
+
T
-
R
+
R
T
+
T
R
+
R
B
-
-
-
31
3
32
4
OUT
COM 2
(RS232)
F
3
1
2
ASCII CONTROL ONLY
COM
1
7
8
ALTERNATE EQUIPMENT
120/230~
50/60 HZ
25 WATTS
DEO OUTPUTS
4
3
5
6
COM 7 & 8
(RS-485 OR RS-232)
2
1
7
8
COM 4
GENEX (RS-485)
ALSO PROGRAMMABLE FOR CM9760-MDA OR ASCII
MAX # OF DEVICES = 8
PROGRAMMABLE FOR KBD100/200/300 SERIES,
ASCII CONTROL, OR CM9760-MDA
COM 3
M DEVICES (RS-485)
MAX # OF DEVICES = 6
MAXIMUM DISTANCE FROM CM6800 = 3,940 FT (1,200 M)
USING 24 AWG COPPER, UNSHIELDED TWISTED PAIR; 16 pF PER FT (pF =PICO FARADS)
5
6
5
6
5
6
4
3
4
3
4
3
2
1
7
8
2
1
7
8
2
1
7
8
4
3
5
6
4
3
5
6
4
3
5
6
4
3
5
6
4
3
5
6
4
3
5
6
4
3
5
6
2
1
2
1
2
1
2
1
2
1
2
1
2
1
7
8
7
8
7
8
7
8
7
8
7
8
7
8
STRAIGHT
CABLES
12V 50 Hz
TRANSFORMER
ALM2064
NUMBER SUPPORTED = 2
64 ALARMS X 2 = 128 ALARMS
CM9505UPS
POWER SUPPLY
KBD960
REL2064
NUMBER SUPPORTED = 2
64 RELAYS X 2 = 128
KBD960
NUMBER SUPPORTED = 2
Figure 11. CM6800 Communication Port Connections and Options
Pelco Manual C1515M-A (11/01)
19
Download from Www.Somanuals.com. All Manuals Search And Download.
KBD100, KBD200, AND KBD300 SERIES KEYBOARDS
You can connect up to eight KBD100/200/300 Series keyboards to any of the following ports:
•
•
•
•
COM 5 (1 direct-powered keyboard or up to 8 remotely connected keyboards)
COM 6 (1 direct-powered keyboard or up to 8 remotely connected keyboards)
COM 7 (up to 8 remotely connected keyboards)
COM 8 (up to 8 remotely connected keyboards)
The total number of KBD100/200/300 Series keyboards connected to the CM6800 cannot
exceed 16.
KBD100, KBD200, and KBD300: Direct-Powered Keyboards
Use COM 5 and 6 (Serial Ports 5 and 6) for direct-powered local keyboards. Each port can
power one KBD100/200/300 Series keyboard.
If you are connecting more than one keyboard to COM 5 or 6, a KBDKIT(-X) is required for
each keyboard. Refer to the KBD100, KBD200, and KBD300: Remote Keyboards section.
1. Using the 25-foot (7.62 m) straight data cable supplied with the keyboard, plug one
end into the RJ-45 connector on the rear of the keyboard.
00603
Figure 12. Data Cable Plugged into Local Keyboard
2. Plug the other end of the data cable into either COM 5 or 6 on the CM6800.
NOTE: If distance between
CM6800 and keyboard
exceeds 25 feet, use
KBDKIT(-X).
00604
Figure 13. Data Cables Plugged into COM 5 and 6
20
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Set the keyboard DIP switches for the desired address for the local keyboard (refer to
Figure 12 and Table D).
Table D. Keyboard Addresses: KBD100/200/300 Series Keyboards
Keyboard
Address
Switch Settings
3
1
2
4
1
2
3
4
5
6
7
8
0
1
2
3
4
5
6
7
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
Table E. Switch Settings—KBD200/300 Keyboards Only
Keyboard
Switch
5
6
7
8
KBD200
KBD300
OFF
OFF
OFF
OFF (NOT USED)
OFF (NOT USED)
OFF
OFF
ON or OFF*
* Switch 6 enables/disables turbo pan (can be switched while keyboard is on).
Pelco Manual C1515M-A (11/01)
21
Download from Www.Somanuals.com. All Manuals Search And Download.
KBD100, KBD200, and KBD300: Remote Keyboards
Use COM 5, 6, 7, or 8 for remote keyboard connections. Each port can support up to eight
KBD100/200/300 Series keyboards. Do not exceed a total capacity of 16 keyboards
connected to the CM6800.
NOTE: A KBDKIT or
KBDKIT-X is required to
connect remote keyboards.
The KBDKIT consists of two
RJ-45 wall blocks and one
120V, 60 Hz to 12V, 60Hz
transformer. The KBDKIT-X
has a 230V, 50 Hz to 12V,
50 Hz transformer. Use one
wall block for each key-
board.
If using COM 7 or 8, you will need to change the settings (the default setting is for an ASCII
device.) Refer to the Programming section for instructions.
1. Select a suitable location for each keyboard and wall block. Wall blocks must be within
6 feet (1.8 m) of a suitable electrical outlet. Do not mount the wall blocks yet.
2. Connect each keyboard to a wall block, using the keyboard data cable supplied with
the keyboard.
3. Remove the wall block covers and wire the connections between each wall block.
Connect to a final wall block (which will be connected to the CM6800).
Communication to the keyboards is RS-485. Pelco recommends using four-conductor,
shielded 18-gauge twisted pairs, such as Belden 9418 or similar cable, that meets or
exceeds the basic requirements for EIA RS-485 applications.
4. At each wall block, wire the KBDKIT(-X) transformer to pins 3 and 4. Polarity is
unimportant.
5. Replace the cover on the wall block. Secure the wall block to a suitable surface. A
double-sided sticky pad is provided to mount the wall block.
6. Set the address switches for each keyboard according to Table D.
NOTE: If you do not
connect keyboards to
7. Connect the final wall block to COM 5, 6, 7, or 8 on the CM6800, using a straight data
cable (supplied with the CM6800).
COM 7 or 8, either port can
be used for a CM9760-MDA
or an ASCII device.
Connection instructions for
CM9760-MDA are provided
as a Pelco Technical Tip.
Refer to the note on page
17. For ASCII devices, refer
to the documentation that
comes with the equipment.
00605
Figure 14. Remote Keyboards
22
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
M DEVICES
M protocol devices (KBD960/KBR960 keyboards, ALM2064 Alarm Interface Units, and
REL2064 Relay Interface Units) can be connected to COM 3 on the CM6800.
If only one device is to be connected to COM 3, use the instructions for that device in the
following sections.
If more than one device is to be connected to COM 3, refer to the Multiple M Devices
section.
Connect M devices to the CM6800 with straight cables. Four straight cables and one
reversed cable are supplied with the CM6800 (save the reversed cable for connecting a
Genex Multiplexer, if applicable).
M Devices Addressing
NOTE: If you wish to use
the partitioning and priority
features of the CM6800, you
must number KBD960/
KBR960 keyboards within a
range of 1-8.
Each M device connected to the CM6800 must have a unique local address within a range
of 1-16. Use the hardware DIP switches to set the appropriate ALM2064 and REL2064
local addresses. Specify the appropriate KBD960/KBR960 local address through the
keyboard Setup Mode after you complete the system installation (refer to the System Start-
Up section).
For use with the CM6800, Pelco recommends numbering M devices in a sequential order.
In a sample application, with two of each M device, you might assign local addresses as
follows:
M device local addresses:
Default
Recommended for CM6800
KBD960/KBR960:
REL2064:
ALM2064:
1
1
1
1, 2
3, 4
5, 6
TO IDENTIFY A CABLE
TYPE, PHYSICALLY
ORIENT THE RJ-45
CABLE AS DEPICTED
IN THE ILLUSTRATIONS.
ORIENT THE CONNECTORS
SIDE BY SIDE. TAB
SIDE DOWN. USE
COMPARED "COLOR RUN"
IS IN OPPOSITE DIRECTION
COMPARED "COLOR RUN"
IS IN SAME DIRECTION
BROWN BROWN
BROWN
BROWN
REVERSED CABLE
STRAIGHT CABLE
THE COLOR RUN
OF THE WIRES TO
DETERMINE CABLE
TYPE.
00612
Figure 15. RJ-45 Cable Types
Pelco Manual C1515M-A (11/01)
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting a Single KBD960/KBR960 Keyboard
To connect a single KBD960/KBR960 Keyboard to the CM6800:
1. Connect the keyboard to the CM9505UPS using the straight cable supplied with the
keyboard.
2. Connect the CM9505UPS to COM 3 on the CM6800 using the 6-foot (1.8 m) straight
data cable supplied with the CM6800.
NOTE: After completing
system installation and
power-up, you must config-
ure the KBD960/KBR960
settings. Refer to the System
Start-Up section.
00607
Figure 16. Connecting a KBD960/KBR960 to the CM6800
24
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting a Single ALM2064 Alarm Interface Unit
To connect a single ALM2064 Alarm Interface Unit:
1. Connect the ALM2064 OUT port to COM 3 on the CM6800 using the 6-foot (1.8 m)
straight data cable supplied with the CM6800.
2. Set SW2, DIP switches 1-8 to the appropriate positions for the local address (default
address setting is 1). Refer to the ALM2064 Alarm Interface Unit Installation/Operation
Manual for instructions.
00608
Figure 17. Connecting a Single ALM2064 Alarm Interface Unit
Pelco Manual C1515M-A (11/01)
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting a Single REL2064 Relay Interface Unit
To connect a single REL2064 Relay Interface Unit:
1. Connect the REL2064 OUT port to COM 3 on the CM6800 using the 6-foot (1.8 m)
straight data cable supplied with the CM6800.
2. Set SW2, DIP switches 1-8 to the appropriate positions for the local address (default
address setting is 1). Refer to the REL2064 Relay Interface Unit Installation/Operation
Manual for instructions.
00609
Figure 18. Connecting a Single REL2064 Relay Interface Unit
26
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
Multiple M Devices
Multiple M devices (KBD960/KBR960, ALM2064, and REL2064) can be connected to COM
3 on the CM6800, either as local devices or remote devices (when connecting two
KBD960/KBR960 keyboards to the CM6800, you must use a remote connection).
MULTIPLE M DEVICES: LOCAL CONNECTION
1. If you are connecting a KBD960/KBR960, connect it to the CM9505UPS with the
straight cable supplied with the keyboard. Then connect the CM9505UPS to the IN
port on the next unit (either the ALM2064 or the REL2064) with a 6-foot (1.8 m)
straight cable (supplied with the CM6800).
2. Connect each ALM2064 and REL2064 unit to the next unit with a 6-foot (1.8 m) straight
cable (supplied with the CM6800) from the OUT port to the IN port on the next unit. You
can connect a maximum of two ALM2064 units and two REL2064 units to the CM6800.
3. Connect the last unit to the CM6800 with a 6-foot (1.8 m) straight cable (supplied with
the CM6800) from the OUT port to COM 3 on the CM6800.
COM 3
DEFAULT SETTINGS: M, RS-485, 19200 BAUD, NO PARITY, 8 DATA BITS, 1 STOP BIT
MAX # OF DEVICES = 6
MAXIMUM DISTANCE FROM CM6800 = 3,940 FT (1,200 M)
ALARM
USING 24 AWG COPPER, UNSHIELDED TWISTED PAIR; 16pF PER FT (pF = PICOFARADS)
1
2
3
4
5
6
7
8
COM
CM6800 COM 3
RJ-45 PIN-OUTS
1
5
CONTROL
PTZ
2
3
4
6
7
8
1 Rx+
2 Rx-
A
T
+
T
-
R
R
T
+
T
R
+
R
B
-
-
-
+
31
3
32
4
3
4
5
6
OUT
STRAIGHT CABLE
(SUPPLIED)
F
3
1
2
GND
COM 1
7 Tx-
8 Tx+
7
8
CM9505UPS
120/230~
50/60 HZ
25 WATTS
DEO OUTPUTS
STRAIGHT CABLE
(SUPPLIED)
STRAIGHT CABLE
(SUPPLIED)
RS-485
ALM2064
ALM2064
KBD960
RJ-45 PIN-OUTS
1 Tx+
KBD960
2 Tx-
RJ-45 PIN-OUTS
3
4
5
6
REL2064
1 Tx+
2 Tx-
REL2064
RJ-45 PIN-OUTS
3
4
5
6
7 Rx-
8 Rx+
1 Tx+
2 Tx-
3
4
5
7 Rx-
8 Rx+
6
7 Rx-
8 Rx+
Figure 19. Connecting Multiple M Devices – Local Connection
Pelco Manual C1515M-A (11/01)
27
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTIPLE M DEVICES: REMOTE CONNECTION
Use a remote connection when the distance from the CM6800 is greater than 6-feet (1.8 m).
1. Connect each ALM2064 and REL2064 unit to a wall block with a 6-foot (1.8 m) straight
cable (supplied with the CM6800). You can connect a maximum of two ALM2064 units
and two REL2064 units to the CM6800.
2. If you are connecting a KBD960, connect it to the CM9505UPS with the straight cable
supplied with the keyboard. Then connect the CM9505UPS to a wall block with a
6-foot (1.8 m) straight cable (supplied with the CM6800). You can connect a maximum
of two KBD960 keyboards to the CM6800.
3. Connect the wall blocks to a final wall block. If additional wall blocks are needed, order
part number CON12J008Z03G0Z.
4. Connect the terminal wall block to COM 3 on the CM6800 using a 6-foot (1.8 m)
straight cable (supplied with the CM6800).
COM 3
DEFAULT SETTINGS:
M, RS-485, 19200 BAUD, NO PARITY, 8 DATA BITS, 1 STOP BIT
MAX # OF DEVICES = 6
ALARM
1
2
3
4
5
6
7
8
COM
MAXIMUM DISTANCE FROM CM6800 = 3,940 FT (1,200 M)
USING 24 AWG COPPER, UNSHIELDED TWISTED PAIR; 16pF PER FT (pF = PICOFARDS)
1
5
CONTROL
PTZ
2
3
4
6
7
8
A
T
+
T
-
R
R
T
+
T
R
+
R
B
CM6800 COM 3
RJ-45 PIN-OUTS
-
-
-
+
31
3
32
4
OUT
F
3
1 Rx+
2 Rx-
1
2
COM 1
3
4
5
6
7
8
GND
120/230~
50/60 HZ
25 WATTS
DEO OUTPUTS
7 Tx-
8 Tx+
STRAIGHT CABLE
(SUPPLIED)
5
6
5
6
5
6
4
3
2
1
4
4
3
2
1
5
6
4
3
2
1
3
2
1
7
8
7
8
7
8
7
8
STRAIGHT CABLE
(SUPPLIED)
ALM2064
REL2064
KBD960
STRAIGHT CABLE
TO CM9505UPS
(SUPPLIED)
CONNECT THROUGH
THE “OUT” PORT
CONNECT THROUGH
THE “OUT” PORT
ALM2064
RJ-45 PIN-OUTS
REL2064
RJ-45 PIN-OUTS
KBD960
RJ-45 PIN-OUTS
1 Tx+
2 Tx-
3
4
5
6
1 Tx+
2 Tx-
3
4
5
6
1 Tx+
2 Tx-
3
4
5
6
7 Rx-
8 Rx+
7 Rx-
8 Rx+
7 Rx-
8 Rx+
Figure 20. Connecting Multiple M Devices – Remote Connection
28
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
CONNECTING A PC
The CM6800 provides PC-based setup and programming software that facilitates complete
switcher programming and configuration. Refer to the CM6800-MGR Quick Start Guide for
instructions on using the software.
Connect a PC to the CM6800 to access the CM6800-MGR software or to download
upgrades to the software. You can connect a PC to the CM6800 through either a DB9 port
or an RJ-45 port. You cannot use both ports simultaneously.
NOTE: You can also
connect an ASCII device
through COM 1, 2, 7, or 8.
Using an ASCII device
through COM 1 requires a
change in serial port
settings. Refer to the
Programming section for
instructions.
1. Using a null modem cable (user-supplied), plug one end into the DB9 COM 1 port on
the PC.
2. Plug the other end of the cable into the DB9 COM 1 port of the CM6800.
NULL MODEM CABLE
PIN 1
PIN 5
CM6800 COM 1
DB9 PIN-OUTS
PC COM 1
DB9 PIN-OUTS
PIN 2 = RX IN
PIN 3 = TX OUT
PIN 5 = GND
PIN 2 = RX IN
PIN 3 = TX OUT
PIN 5 = GND
00613
PIN 9
PIN 6
Figure 21. PC Connection to DB9 Port
OR
1. Using a modified null modem cable (user-supplied), connect the DB9 COM 1 port on
the PC to an RJ-45 wall block (supplied with the CM6800 Matrix Switcher).
The modified null modem cable should be cut at one end, so that you can connect the
wires directly to the wall block pins.
2. Using a 6-foot (1.8 m) data cable (supplied with the CM6800 Matrix Switcher), connect
the wall block to the RJ-45 COM 1 port of the CM6800.
CM6800 COM 1
RJ-45 PIN-OUTS
PC COM 1
DB9 PIN-OUTS
PIN 1 = RX IN
PIN 5 = GND
PIN 8 = TX OUT
PIN 2 = RX IN
PIN 3 = TX OUT
PIN 5 = GND
CM6800 COM 1
PC COM 1
RJ-45 WALL BLOCK
AND STRAIGHT CABLE
SUPPLIED WITH CM6800
MODIFIED NULL MODEM CABLE
(USER-SUPPLIED)
00992
Figure 22. PC Connection to RJ-45 Port
Pelco Manual C1515M-A (11/01)
29
Download from Www.Somanuals.com. All Manuals Search And Download.
CONNECTING GENEX MULTIPLEXERS
Use COM 4 to connect up to eight Genex Multiplexers to the CM6800.
NOTE: If you do not con-
nect multiplexers to COM 4,
you can connect a
CM9760-MDA or an ASCII
device through COM 4. Us-
ing either device requires a
change in serial port set-
tings. Refer to the Program-
ming section.
1. Connect the COM IN port of the multiplexer to COM 4 on the CM6800, using the
6-foot (1.8 m) reversed data cable supplied with the CM6800.
One reversed cable and four straight cables are supplied with the CM6800. Use the
reversed cable for connecting the Genex multiplexer to the CM6800.
A straight data cable is supplied with the Genex multiplexer. Use this cable for
connecting a second Genex multiplexer to the first multiplexer, if necessary.
2. Connect the MAIN monitor output from the multiplexer to any of the 48 camera inputs
on the CM6800.
3. Connect cameras to the multiplexer and then loop them to the CM6800. Refer to the
MX4000 Genex Series Simplex and Duplex Multiplexers Installation/Operation Manual
for detailed camera connection instructions. Terminate the video loop at the CM6800.
4. If required, you can connect a total of eight Genex multiplexers through COM 4. Daisy-
chain the multiplexers by connecting a straight data cable from the COM OUT port on
the first multiplexer to the COM IN port on the second multiplexer; connect the COM
OUT port on the second multiplexer to the COM IN port on the third multiplexer.
Continue to the eighth multiplexer, if necessary.
Refer to the System Start-Up section for additional configuration steps required when using
a Genex Multiplexer.
ALARM
1
2
3
4
5
6
7
8
HZ
COM
9
10
11
12
13
14
15
16
1
2
3
19
35
4
20
36
5
6
7
8
75
1
5
CONTROL
PTZ
2
3
4
6
7
8
A
T
+
T
-
R
+
R
T
+
T
R
+
R
B
-
-
-
25
41
45
26
42
46
27
43
47
28
44
48
29
1
30
2
31
3
32
4
17
33
18
34
21
37
22
38
23
39
24
40
OUT
F
3
1
2
COM
1
5
6
7
8
120/230~
50/60 HZ
25 WATTS
ALTERNATE SOURCE INPUTS
VIDEO OUTPUTS
REVERSED CABLE
SPOT MIN
VCR
IN COM OUT
ALARMS
N
NH
OCC S
OUT
IN
AUX
MONITOR SIGNAL OUT
110-240V 50/60 Hz
1
2
3
4
5
6
7
8
9
10 111213141516
SVHS
SVHS
GENEX MULTIPLEXER
STRAIGHT CABLE
SPOT MAIN
AUX
VCR
SVHS
VCR
IN COM OUT
IN
ALARMS
N
NH
OCC S
OUT
110-240V 50/60 Hz
1
2
3
4
5
6
7
8
9
10 111213141516
SVHS
GENEX MULTIPLEXER
RJ-45 PIN-OUTS
CM6800 COM 4
RJ-45 PIN-OUTS
GENEX MULTIPLEXER
GENEX MULTIPLEXER
STRAIGHT CABLE
Rx+ 1
Rx- 2
12VAC (OUT) 3
12VAC (OUT) 4
GROUND 5
NC 6
1 Rx+
2 Rx-
3 NC
4 NC
5 GROUND
6 NC
SPOT MAN
IN COM OUT
IN
ALARMS
N
NH
OCC S
OUT
AUX
110-240V 50/60 Hz
1
2
3
4
5
6
7
8
9
10 111213141516
SVHS
SVHS
Tx- 7
Tx+ 8
7 Tx-
8 Tx+
GENEX MULTIPLEXERS-8 MAXIMUM
00616
Figure 23. Connecting Genex Multiplexers
30
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL AUXILIARIES
The CM6800 provides three local auxiliary (AUX) outputs on the rear panel for controlling
VCRs, printers, and other devices. These outputs can be activated directly from a keyboard
by using the F1, F2, and F3 function keys, or they can be activated by an alarm (deter-
mined by programming). Both relay contacts and TTL outputs are used.
In addition, you can connect up to two REL2064 Relay Interface Units to the CM6800. Note
that since operation of the three internal auxiliary relays on the CM6800 will also operate
the first three relays on the external unit, the maximum capacity of the system may be
limited to 128 auxiliaries (depending on how you number the external relays). Refer to the
Connecting a Single REL2064 Relay Interface Unit section for connection instructions.
CONNECTING RELAY CONTACTS – AUX 1 AND 2
AUX 1 and 2 are dry contact relay outputs. Refer to Figure 25 for wiring details. Terminal
connections are provided for both normally open (N.O.) and normally closed (N.C.) contacts.
Do not exceed the voltage and current ratings for the relay contacts.
You will need to provide an external power source to operate your device. In most cases
you will also need an external current limiting resistor. The formula for calculating the
resistor value is given in Figure 25.
00617
Figure 24. Wiring the AUX 1 and 2 (Relay) Outputs
Pelco Manual C1515M-A (11/01)
31
Download from Www.Somanuals.com. All Manuals Search And Download.
CONNECTING THE OPEN COLLECTOR OUTPUT – F3 (TTL)
F3 is a TTL open collector output. This output provides a path to ground to control the low
voltage trigger input on many devices. It can control higher voltage control inputs via
isolation relays. Refer to Figure 26 for wiring details.
Do not exceed the voltage and current ratings for the TTL output.
An external pull-up resistor is usually necessary. The formula for calculating the resistor
value is given in Figure 26.
00618
Figure 25. Wiring the F3 (TTL) Output
32
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
SYSTEM START-UP
After completing the system installation, follow the procedure below to start proper system
operation. Skip any “system-specific” steps that do not apply to your system setup.
POWER-UP THE SYSTEM
Plug the CM6800 power cord into a 120/230V, 50/60 Hz power source. Plug in and turn on
all devices connected to the CM6800.
Once the system is powered-up you will see video from camera 1 and the following time/
date stamp on all system monitors:
00620
Figure 26. CM6800 Time/Date Stamp on Monitor
The time stamp will be advancing in one-second increments. Wait five seconds before
proceeding.
INITIALIZE KEYBOARDS
You must specify a monitor for each keyboard after your first power-up or any time power is
cycled to the keyboard or the CM6800.
Always allow five seconds to elapse before specifying a monitor.
1. Enter a number (1-8) corresponding to the monitor output that is feeding the monitor
you are viewing.
2. Press the MON key. The keyboard LED displays the number you entered. This also
confirms successful communication between the keyboard and the CM6800. If the
keyboard LED does not display the monitor number, repeat 1 and 2.
If you are unable to select the monitor, refer to the Troubleshooting section.
CONFIGURE THE SYSTEM
If necessary, configure the CM6800 and associated equipment to your specific application.
The CM6800 is shipped from the factory with default programming settings. If the defaults
are acceptable, the CM6800 can be operated without any user programming. However, you
may want to program the basic system settings, such as time and date, and camera titles.
In addition, some or all of the following configuration steps may be necessary, depending
on your system.
Configure the CM6800 through Programming mode. Refer to the Programming section for
detailed instructions.
TIME AND DATE
Access the Time & Date programming screen to set the time and date, and select the time/
date format option.
Pelco Manual C1515M-A (11/01)
33
Download from Www.Somanuals.com. All Manuals Search And Download.
CAMERA TITLES
By default each camera is titled “CAM #” (# = camera number from 1-48). Access the
Camera programming screen to change the camera titles.
VIDEO SOURCES
Extended Coaxitron protocol receivers can be operated without any programming changes.
For other receiver control protocols, access the Camera programming screen to select the
control type for the device connected to each video input. Control can be through standard
mode Coaxitron, extended mode Coaxitron, RS-422 PTZ through Port A or Port B on the
rear panel, or through a Genex Multiplexer.
For RS-422 PTZ control you must configure the CM6800:
•
•
Access the Camera programming screen to identify the receiver control type
(PTZ-A or PTZ-B) and to select the appropriate camera port address. The
camera port address must match the address setting configured through the
camera/receiver DIP switch settings.
Access the Port programming screen to select the appropriate communication
type (P or D) for serial ports 9 (PTZ-A) and 10 (PTZ-B). Default settings for PTZ-
A and PTZ-B: PTZ-P, RS-422, 4800 baud, no parity, 8 data bits, 1 stop bit.
You must also configure the camera/receiver. Refer to the appropriate camera/receiver
installation manual for configuration and address settings.
ALARMS
The CM6800 is shipped from the factory with the alarm contact enable field set to OFF. To
use the alarm features, access the Alarm programming screens to enable the alarm
contact.
COMMUNICATION PORTS
If you are using any communication port for a device not specified by the default setting,
you must access the Port programming screen to change the settings.
Table F. Default Port Settings
Port
Default Settings
COM 1
MGR, RS-232, 56000 baud, no parity, 8 data bits, 1 stop bit
ASCII, RS-232, 9600 baud, no parity, 8 data bits, 1 stop bit
M, RS-485, 19200 baud, no parity, 8 data bits, 1 stop bit
MUX, RS-485, 9600 baud, odd parity, 8 data bits, 1 stop bit
KBD-300, RS-485, 9600 baud, odd parity, 8 data bits, 1 stop bit
ASCII, RS-485, 9600 baud, no parity, 8 data bits, 1 stop bit
PTZ-P, RS-422, 48 baud, no parity, 8 data bits, 1 stop bit
PTZ-P, RS-422, 48 baud, no parity, 8 data bits, 1 stop bit
COM 2
COM 3
COM 4
COM 5, 6
COM 7, 8
PTZ-A (Port 9)
PTZ-B (Port 10)
KBD960/KBR960 KEYBOARD
Configure the KBD960/KBR960 settings.
1. Set DIP switch 2 to the ON position.
2. Enter Setup Mode. Set the local address (1-8). (Note: the baud rate is set by default to
19200.) Each M device connected to the CM6800 must have a unique local address.
Refer to the KBD960/KBR960 Keyboard Installation/Operation Manual for detailed
setup instructions.
3. Return DIP switch 2 to the OFF position.
4. Press the EXIT icon on the keyboard LCD screen.
34
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
GENEX MULTIPLEXER
Access the Camera programming screen and specify MUX control for all cameras
connected to the CM6800 through the Genex Multiplexer.
Access the CM6800 Camera programming screen to configure the following camera control
options for each camera connected to the CM6800 through the Genex Multiplexer:
•
•
CONTROL: MUX
PORT ADDRESS: assign the appropriate address. The port address must match
the “Unit ID” assigned through the Genex programming screens.
You must also configure the Genex Multiplexer. Refer to the MX4000 Genex Series
Simplex and Duplex Multiplexers Installation/Operation Manual (C1920M-B) for instructions
on accessing the Advanced System Setup programming screen. Select the following
options:
•
•
•
SPOT MONITOR DISPLAY: TRACK MAIN
UNIT ID (must match the port address assigned through the CM6800)
COMM. TYPE: SLAVE (each multiplexer connected to the CM6800 must be in
slave mode)
MONITOR COLOR ADJUSTMENT:
Once you have connected all devices and powered the system, use the CM6800 color bars
as a reference tool for adjusting the color on each monitor.
1. Enter 9999.
2. Press the CAM key. Broadcast quality color bars appear on the monitor.
3. Adjust color on each monitor as necessary until the color bars match the following
color order on the monitor (for black and white monitors you can use the color bars to
adjust brightness):
00630
Figure 27. CM6800 Color Bars
PROGRAM PRESETS
Program presets as necessary for your system. Refer to the appropriate keyboard manual
for instructions.
ADDITIONAL PROGRAMMING
Refer to the Programming section for complete instructions on programming the CM6800.
Pelco Manual C1515M-A (11/01)
35
Download from Www.Somanuals.com. All Manuals Search And Download.
PROGRAMMING THE CM6800
The CM6800 is shipped from the factory with default programming settings. If the defaults
are acceptable, the CM6800 can be operated without any user programming. However, you
may want to program the following basic system settings:
•
•
•
•
Time and date
Camera titles
PTZ control via hardwire data connections
Alarm contacts
Alarms must be enabled before they are functional.
•
•
Access/Partitioning
All access is set to YES by factory default.
Communication ports
If you connect your system as illustrated in the Quick Start Guide, you must
change the settings for Port 7 or 8 in order to connect remote keyboards.
You can further customize your system with a wide range of programming options, such as:
•
•
•
•
•
•
•
select the language displayed on programming screens
establish monitor group sequences
set monitor display options
set alarm handling options
assign logical camera numbering
change password
set auxiliary options
CUSTOMIZING THE CM6800
NOTE: The CM6800 allows
system programming from
only one monitor at a time. If
programming from the
CM6800-MGR is sent to the
CM6800 at the same time
that you are programming
from a monitor screen, the
system will exit the on-screen
programming function.
Pelco provides two options for programming the CM6800 to your specifications:
•
•
Password-protected, on-screen programming screens accessible directly from
the Matrix Switcher
PC-based CM6800-MGR software
Refer to the CM6800-MGR Quick Start Guide for instructions on accessing and
using this software to program your system.
NOTE: Pelco strongly recommends uploading your programming settings
to the CM6800-MGR to save settings in the event of an accidental reset.
36
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESS PROGRAMMING MODE FROM THE CM6800
KBD100/200/300 Keyboards
KBD960/KBR960 Keyboards
1. Press the PGM key.
NOTE: If you have not
already done so, enter the
monitor number and press
the MON key to select the
monitor. On the KBD960/
KBR960, the Camera menu
appears on the LCD display.
1. Select
2. Select
.
.
DEF
3. Enter the Define PIN (Default: 1234).
MENU
4. Select
5. Select
.
.
PGM
The Password screen appears on the monitor.
Press
to exit the
Camera menu.
PELCO VIDEO SWITCHER
MODEL CM6800
PASSWORD TO MAIN MENU
*******
SCRATCHPAD SEQUENCE
MACRO STATUS VIEW
RETURN
Figure 28. CM6800 Password Screen
At the ******* prompt, enter the DEFAULT PASSWORD: 2899100
The Main Menu appears.
PELCO SWITCHER
MODEL CM6800
MAIN MENU
1
2
3
4
5
6
7
8
9
CAMERA
LOGICAL CAMERA
MONITOR
ACCESS
TIME & DATE
PORT
PRIORITY
SEQUENCE
MACRO
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
ENGLISH
RETURN
00654
Figure 29. CM6800 Programming Main Menu
If necessary, select the appropriate language.
1. Navigate to the language displayed below the menu options.
2. Scroll through the languages and select the language appropriate for your system.
OPTIONS:
ENGLISH
ESPANOL
DEUTSCH
FRANCAIS
PORTUGUESE
ITALIANO
3. Navigate to the RETURN field and navigate left or right to return to the Main Menu.
Pelco Manual C1515M-A (11/01)
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Exit Programming Mode
KBD100/200/300 Keyboards
KBD960/KBR960 Keyboards
To return to active video you can:
To return to active video you can:
•
Press the PGM key once while
in the Main Menu.
PGM
•
•
•
Select
Menu.
once while in the Main
•
Press the PGM key twice from
anywhere else in the program-
ming screens.
PGM
Select
twice from anywhere else in
the programming screens.
Navigate to the RETURN field and
navigate left or right to return to the
previous screen or menu.
•
Navigate to the RETURN field
and navigate left or right to
return to the previous screen or
menu.
NAVIGATE AND SELECT OPTIONS/FIELD ENTRIES IN
PROGRAMMING MODE
During programming, a menu appears on the monitor screen. The currently selected field blinks.
Use the following keys or joystick on your keyboard to navigate the programming screens.
Function
Keyboard
Navigate programming screens.
KBD100
Use the sequence and macro keys.
Left
Right
Up
Down
MAC
PREV
NEXT
HOLD
KBD200
Use the Pan/Tilt positioning keys.
Left
Right
Up
Down
KBD300
Use the joystick.
TIP: To access a screen
or enter a value, press a
number key on the keyboard
and then press F1
Left
Right
Up
Down
KBD960/KBR960
(KBD100/200/300) or select
(KBD960/KBR960).
Use the joystick. (See above icons)
OR
Select the appropriate icon on the
KBD960/KBR960 LCD SCREEN.
Left
Right
Up
Down
Access a screen from the Main
Menu (or from a submenu).
All Keyboards
1. Navigate down to the desired menu
option.
2. Navigate left or right to select the menu
option.
OR
1. Using the numerical keypad, enter the
number of the menu option.
2. Press F1 on the KBD100/200/300
keyboard or select
KBR960 keyboard.
on the KBD960/
38
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
Function
Keyboard
Scroll through options in
programming fields.
KBD100/200/300
Use F1 and F2. Or (KBD300 only) use the
joystick to navigate left or right.
F1
F2
NOTE: The joystick does not scroll options
in all fields.
KBD960/KBR960
Select the
or
icons or use the
joystick to navigate left or right.
NOTE: The joystick does not scroll options
in all fields.
All keyboards
Select option in a programming field.
1. Scroll through the options until the
appropriate entry appears in the field.
2. Navigate to the next field or press PGM
to exit.
NOTE: On the Monitor and Time & Date
screens you must apply the changes (refer
to Time & Date or Monitor in this section).
Enter a numerical value in an option
field (not available in all fields).
All keyboards
1. Using the numerical keypad, enter a
number within the range of valid options
(example: to enter an internal alarm
contact you must enter a number
between 1 and 8).
2. Press F1 on the KBD100/200/300
keyboard or select
KBR960 keyboard.
on the KBD960/
Access the HELP screen
(Sequences, Macros, and Alarm
Group screens).
All keyboards
1. Navigate to the HELP field.
2. Press F1.
All keyboards
Access the NEXT or PREVIOUS
page of a list (not available on every
screen).
1. Navigate to the NEXT or PREVIOUS
field.
2. Press F1.
Exit a screen.
All keyboards
1. Navigate to the RETURN field.
2. Navigate left or right.
OR
Press the PGM key to return to the previous
screen or menu.
Pelco Manual C1515M-A (11/01)
39
Download from Www.Somanuals.com. All Manuals Search And Download.
ABOUT CM6800
The About CM6800 screen displays system version levels.
PELCO SWITCHER
MODEL CM6800
ABOUT CM6800
MAIN MENU
CODE:
VERSION
VER MON
VER CXT
CER CPU
VER VID
V1.03
V1.02
V1.02
V1.02A
V1.02
MONITOR FPGA:
COAX FPGA:
CPU FPGA:
1
2
3
4
5
6
7
8
9
CAMERA
LOGICAL CAMERA
MONITOR
ACCESS
VIDEO FPGA:
FONTS
VER FNT
V1.02
TIME & DATE
PORT
PRIORITY
SEQUENCE
MACRO
ITALIAN:
PORTUGUESE:
FRENCH:
GERMAN:
SPANISH:
ENGLISH:
VER ITA
V1.02
V1.02
V1.02
V1.02
V1.02
V1.02
VER POR
VER FRE
VER GER
VER SPA
VER ENG
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
BOOTROM
EID#:
VER V1.01
113-145119079400000
ENGLISH
RETURN
RETURN
00654
Figure 30. Access the About CM6800 Screen
ACCESS (SYSTEM PARTITIONING)
The CM6800 supports the following system partitioning to control switching system access:
NOTE: To use partitioning
for keyboards, all keyboard
addresses must be within a
range from 1-8.
Keyboard to Monitor:
Camera to Keyboard:
Restrict a keyboard from accessing selected monitors.
Restrict a keyboard from calling selected cameras to monitors. Or
video viewing only: permit the viewing of selected cameras while
preventing pan and tilt control.
Camera to Monitor:
Restrict the viewing of selected cameras on selected monitors.
All system access is set to YES by default.
Keyboard to Monitor Access
Use the Keyboard to Monitor Access screen to assign keyboards control of specific
monitors.
PELCO SWITCHER
MODEL CM6800
MAIN MENU
KEYBOARD TO MONITOR ACCESS
ACCESS
PORT 7
1
2
3
KEYBOARD TO MONITOR
CAMERA TO KEYBOARD
CAMERA TO MONITOR 1-8
1
2
3
4
5
6
7
8
9
CAMERA
MON
KEYBOARD
LOGICAL CAMERA
MONITOR
ACCESS
1
2
3
4
5
6
7
8
RETURN
1
2
3
4
5
6
7
8
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
N
N
N
N
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
TIME & DATE
PORT
PRIORITY
SEQUENCE
MACRO
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
ENGLISH
RETURN
00636
00654
00651
Figure 31. Access the Keyboard to Monitor Access Screen
NOTE: If you connect an
ASCII keyboard/device to
the CM6800 (COM port 1, 2,
4, 7, or 8), you can connect
only one keyboard to a port.
Specify access in the first
column only (address 1).
PORT:
Select the COM port number for which you are programming access
control (1-8).
In each monitor row specify the access allowed for each keyboard (address 1-8) to control
each specific monitor (1-8).
OPTIONS:
Y = Yes; control is allowed
N = No; control is not allowed
40
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
Camera To Keyboard Access
Use the Camera to Keyboard Access screen to assign keyboards full control or view-only
control of specific cameras.
PELCO SWITCHER
MODEL CM6800
MAIN MENU
CAMERA TO KEYBOARD ACCESS
ACCESS
PORT 5
KEYBOARD
1
2
3
KEYBOARD TO MONITOR
CAMERA TO KEYBOARD
CAMERA TO MONITOR 1-8
CAM
0001
0002
0003
0004
0005
0006
0007
0008
0009
0010
0011
0012
0013
0014
0015
0016
1
V
V
V
V
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
2
Y
Y
Y
Y
N
N
N
N
Y
Y
Y
Y
Y
Y
Y
Y
3
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
4
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
5
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
6
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
7
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
8
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
1
2
3
4
5
6
7
8
9
CAMERA
LOGICAL CAMERA
MONITOR
ACCESS
RETURN
TIME & DATE
PORT
PRIORITY
SEQUENCE
MACRO
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
ENGLISH
RETURN
NEXT
PREVIOUS
RETURN
00636
00654
00644
Figure 32. Access the Camera to Keyboard Access Screen
PORT:
Select the COM port number for which you are programming access
control (1-8); keyboards are identified by their physical connection to
the switcher.
In each camera row specify the access allowed for each keyboard (address 1-8) to view
and control the specific logical camera number; select NEXT or PREVIOUS to continue to
the next group of camera numbers.
OPTIONS:
Y = Yes; viewing and control is allowed
N = No; viewing and control is not allowed
V = View only; camera can be viewed but not controlled
Camera To Monitor Access
Use the Camera to Monitor Access screen to assign monitors viewing access to specific
cameras.
PELCO SWITCHER
MODEL CM6800
MAIN MENU
CAMERA TO MONITOR ACCESS
ACCESS
MONITOR
CAM
0001
0002
0003
0004
0005
0006
0007
0008
0009
0010
0011
0012
0013
0014
0015
0016
1
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
2
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
3
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
4
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
5
Y
Y
Y
N
N
N
N
N
Y
Y
Y
Y
Y
Y
Y
Y
6
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
7
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
8
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
1
2
3
KEYBOARD TO MONITOR
CAMERA TO KEYBOARD
CAMERA TO MONITOR 1-8
1
2
3
4
5
6
7
8
9
CAMERA
LOGICAL CAMERA
MONITOR
ACCESS
RETURN
TIME & DATE
PORT
PRIORITY
SEQUENCE
MACRO
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
ENGLISH
RETURN
NEXT
PREVIOUS
RETURN
00636
00654
00645
Figure 33. Access the Camera to Monitor Access Screen
In each camera row specify the access allowed for each monitor (1-8) to display the
specific logical camera number; select NEXT or PREVIOUS to continue to the next group of
camera numbers.
OPTIONS:
Y = Yes; camera can be viewed
N = No; camera cannot be viewed
Pelco Manual C1515M-A (11/01)
41
Download from Www.Somanuals.com. All Manuals Search And Download.
ALARM CONTACTS
The CM6800 provides a wide variety of alarm handling and display options. Alarmed
cameras can be displayed on one or several monitors as part of one or several alarm
groups (each monitor can display only one alarm group.) You can also customize the
system to handle alarms in the following ways:
NOTE: You cannot access
the Alarm Contacts screen
when an alarm is active.
The message MONITOR:
00# IS IN ALARM. ACCESS
IS DENIED appears (the
appropriate monitor number
appears in place of “00#”).
•
•
•
•
•
•
the order in which alarms are displayed
automatic or manual acknowledgement of alarms
activation of auxiliaries by alarms
automatic activation of presets or patterns
N.O. or N.C. operation
priority assignment
Before programming alarm settings, verify that no automated system functions are set to
run, such as a macro that would arm or disarm an alarm. Ensure that system operators do
not arm or disarm any alarms while you are programming the alarm settings. If an alarm is
triggered while you are in the CM6800 programming screens, or while programming a
pattern, preset or zone, the system will exit the on-screen programming function and
display the alarm on the appropriate monitor(s).
When programming an alarm to appear on a specific monitor, verify that the monitor has
access to the camera view triggered by the alarm. Partitioning has priority over alarm
programming, so if an alarm is cued to a monitor that does not have access to the
appropriate cameras, the camera views cannot be monitored.
Alarm Contact Programming Tasks
To configure the CM6800 internal alarm contacts you must access the Alarm Contact
screen to complete the following minimum tasks:
•
•
•
Enable the alarm contact.
Specify at least one camera step with a dwell greater than zero for each alarm contact.
Assign the alarm to at least one alarm group.
The following alarm handling options are set by factory default:
•
•
•
•
•
Acknowledgement type = manual
Time out = 10 seconds
Alarm sensor type = N.O. (normally open)
Priority level = 0
Alarm group display option = Block Build
To change these defaults, or to configure external alarm contacts, refer to the following
sections for detailed programming instructions.
Alarm Group Display Options
To display on a monitor, an alarm must be assigned to an alarm group (A-H). Before
programming alarms you may want to determine the alarm display format for each
alarm group. An alarm can include up to eight steps, so eight camera views could
display as a part of each alarm.
A priority alarm appears on system monitors before non-priority alarms, despite the order
specified by the alarm group assignment. In the examples below, all alarms are at the same
priority level. Refer to the PRIORITY description in Program Internal and External Alarms.
42
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
BLOCK BUILD
Alarmed cameras are displayed across a block of alarm monitors in a sequential order. All
steps programmed for the alarm contact appear on the designated monitor.
Example: Eight alarms set to display on monitors 02-07 will appear in the following order:
ALARM MONITOR GROUP SETUP
1st Display
Cycle
Next Display
Cycle
Acknowledging
Alarms 1 & 2
Next Display
Cycle
MON
A
B
C
D
E
F
G
H
Monitor
01
02
03
04
05
06
07
08
—
B
B
B
B
B
B
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
02 B
1st alarm
1st and 7th
alarms cycle
Acknowledge
1st alarm
7th alarm
03 B
2nd alarm
2nd and 8th
alarms cycle
Acknowledge
2nd alarm
8th alarm
HELP
04 B
05 B
06 B
07 B
3rd alarm
4th alarm
5th alarm
6th alarm
3rd alarm
4th alarm
5th alarm
6th alarm
3rd alarm
4th alarm
5th alarm
6th alarm
3rd alarm
4th alarm
5th alarm
6th alarm
00638
New alarms display on the lowest monitor number with the fewest alarms cycling.
CHRONOLOGICAL PAIR: D AND Q
The oldest alarm of a specific group is displayed on one designated monitor, while all other
alarms in the group are sequenced on the second designated monitor. All steps pro-
grammed for the alarm contact appear on the designated monitor.
Example: Four alarms set to display on monitors 04 and 05 will appear in the following order:
ALARM MONITOR GROUP SETUP
Monitor
04 D
1 Alarm
2 Alarms
1st alarm
2nd alarm
3 Alarms
4 Alarms
MON
A
B
C
D
E
F
G
H
1st alarm
1st alarm
1st alarm
01
02
03
04
05
06
07
08
—
—
—
—
—
—
—
—
—
—
—
D
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
05 Q
2nd and 3rd
alarms cycle
2nd, 3rd, and 4th
alarms cycle
Q
—
—
—
You must acknowledge alarms in a chronological pair from the display monitor (D). Then
the next oldest alarm moves to the display monitor and the remaining alarms continue to
cycle through the queue monitor (Q). This format requires you to acknowledge each alarm
in the order in which they occur.
HELP
00640
Acknowledging alarms in this example:
Monitor
1st Cycle
Next Cycle
Next Cycle
Next Cycle
04 D
Acknowledge
1st alarm
Acknowledge
2nd alarm
Acknowledge
3rd alarm
Acknowledge
4th alarm
05 Q
2nd, 3rd, and 4th
alarms cycle
3rd and 4th
alarms cycle
4th alarm
Pelco Manual C1515M-A (11/01)
43
Download from Www.Somanuals.com. All Manuals Search And Download.
REVERSE CHRONOLOGICAL PAIR: M AND L
The most recent alarm of a specific group is displayed on one designated monitor, while all
other alarms in the group are sequenced on the second designated monitor. All steps
programmed for the alarm contact appear on the designated monitor.
Example: Four alarms set to display on monitors 06 and 07 will appear in the following order:
ALARM MONITOR GROUP SETUP
Monitor
06 M
1 Alarm
2 Alarms
2nd alarm
1st alarm
3 Alarms
4 Alarms
MON
A
B
C
D
E
F
G
H
1st alarm
3rd alarm
4th alarm
01
02
03
04
05
06
07
08
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
M
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
07 L
1st and 2nd
alarms cycle
1st, 2nd, and 3rd
alarms cycle
L
—
HELP
You must acknowledge alarms in a reverse chronological pair from the display monitor (M).
Then the next most recent alarm moves to the display monitor and the remaining alarms
continue to cycle through the queue monitor (L). This format requires you to acknowledge
each alarm in the reverse order from which they occurred.
00641
Acknowledging alarms in this example:
Monitor
1st Cycle
Next Cycle
Next Cycle
Next Cycle
06 M
Acknowledge
Alarm 4
Acknowledge
Alarm 3
Acknowledge
Alarm 2
Acknowledge
Alarm 1
07 L
Alarms 1, 2,
and 3 cycle
Alarms 1
and 2 cycle
Alarm 1
SALVO SWITCHING
Multiple camera views within the alarm contact programming (the “steps”) are displayed
simultaneously as a group across a set of monitors. When a new alarm triggers, all
monitors switch to the new alarm at the same time.
When programming a Salvo Group:
•
Program the Salvo Group to display across a number of monitors equal to the
number of steps in the alarm contact(s); for example if the alarm contact has six
steps, set the Salvo Group to display on six monitors. If an alarm contact
contains more steps than monitors defined for the Salvo Group, the additional
steps do not appear on a monitor during the alarm.
•
•
Each alarm contact assigned to the Salvo Group should contain the same
number of steps.
The Salvo Group switches based on the dwell time entered for the first step in
the alarm contact.
ALARM MONITOR GROUP SETUP
Example: Two alarm contacts with three steps display on three monitors will appear as follows:
MON
A
B
C
D
E
F
G
H
01
02
03
04
05
06
07
08
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
S
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
After
Acknowledging
1st Alarm
Next Display
Cycle
Monitor 1 Alarm
2 Alarms
S
S
06 S
07 S
08 S
1st alarm, step 1 2nd alarm, step 1
1st alarm, step 2 2nd alarm, step 2
1st alarm, step 3 2nd alarm, step 3
1st alarm, step 1
1st alarm, step 2
1st alarm, step 3
2nd alarm, step 1
2nd alarm, step 2
2nd alarm, step 3
HELP
00639
44
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
Internal and External Alarms
Use the Internal Alarm screen to configure the eight internal alarm inputs on the rear panel
of the matrix switcher/controller; internal inputs are programmable to associate any camera
to any input. When an internal alarm is triggered, the alarm icon and an “I” appear on
designated system monitors.
Use the External Alarm screen to configure the alarm inputs on external devices; up to 128
additional inputs are available by connecting up to two ALM2064 Alarm Interface Units. When
an external alarm is triggered, the alarm icon and an “E” appear on designated system
monitors.
The procedure for programming internal and external alarms is the same, except for selecting
the alarm input type (the TYPE field on the Internal Alarm screen). Set the external alarm
input type (N.O. or N.C.) through the ALM2064 Alarm Interface Unit. Refer to the ALM2064
Alarm Interface Unit Installation/Operation Manual for instructions.
INTERNAL ALARM MENU
CONTACT:
ACK TYPE: MANUAL
TYPE:
1
ENABLE:
TIME OUT: 10
PRIORITY:
OFF
NO
DWL CMD
01 PRES
0
STP CAM
## AUX
13
##
1
2
3
4
5
6
7
8
0001
0001
0001
0001
0001
0001
0001
0001
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
00
00
00
00
00
00
00
— — — —00
— — — —00
— — — —00
— — — —00
— — — —00
— — — —00
— — — —00
PELCO SWITCHER
MODEL CM6800
MAIN MENU
ALARM CONTACTS
1
2
3
4
INTERNAL CONTACT
EXTERNAL CONTACT
VIDEO LOSS
1
2
3
4
5
6
7
8
9
CAMERA
GROUP ENABLE
LOGICAL CAMERA
MONITOR
ACCESS
A
B
N
C
D
E
F
G
H
ALARM GROUP
Y
N
N
N
N
N
N
RETURN
TIME & DATE
PORT
PRIORITY
SEQUENCE
MACRO
RETURN
00650
10 ALARM CONTACTS
11 EVENT TIMER
EXTERNAL ALARM MENU
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
CONTACT: 001
ACK TYPE: MANUAL
ENABLE:
TIME OUT: 10
OFF
PRIORITY:
0
ENGLISH
RETURN
STP CAM
DWL CMD
##
AUX
##
1
2
3
4
5
6
7
8
0001
0001
0001
0001
0001
0001
0001
0001
00
00
00
00
00
00
00
00
— — — —00
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —00
— — — —00
— — — —00
— — — —00
— — — —00
— — — —00
— — — —00
00654
00642
GROUP ENABLE
A
B
N
C
D
E
F
G
H
N
N
N
N
N
N
N
RETURN
00649
Figure 34. Access the Internal or External Alarm Screen
CONTACT:
Select the alarm input number for programming.
OPTIONS:
Internal alarms: 1-8
External alarms: 1-128
ENABLE:
Enable the alarm contact by selecting ON (Default = OFF); to complete
the process of enabling an alarm contact, you must also
•
•
set at least one camera with a dwell time greater than 0 (refer to the
STP description),
assign the alarm contact to an alarm group (refer to the GROUP
ENABLE description).
ACK TYPE:
Select the alarm clearance type.
OPTIONS:
MANUAL = alarm must be acknowledged from a system keyboard
AUTO =
alarm will time out automatically after the interval specified
in the TIME OUT field
Pelco Manual C1515M-A (11/01)
45
Download from Www.Somanuals.com. All Manuals Search And Download.
TIME OUT:
TYPE:
Enter the amount of time (0-99 seconds) alarm remains active after the
contact has cleared (AUTO alarms only).
Select the alarm input type (Internal Alarms only).
OPTIONS:
N.O. = normally open
N.C. = normally closed
PRIORITY:
Select the priority level of the alarm; a priority alarm appears on
system monitors before a non-priority alarm.
OPTIONS:
0 = non-priority
1 = priority
STP:
Each alarm contact can include up to eight steps to be activated as a
result of this alarm. For each step select entries in the following fields as
necessary.
CAM:
DWL:
Enter the logical number of the camera to be
displayed; must be a valid logical number (0001-9998).
Enter the amount of time the camera view is
displayed in an alarm sequence (0-99 seconds); to
enable the alarm contact you must set at least one
camera with a dwell time greater than 0.
CMD and ##:
Select a camera operation; if you select a pattern or
a preset, enter a valid pattern or preset number.
OPTIONS:
PRES = preset
PATT = pattern
RSCN = random scan
FSCN = frame scan
SSCN = stop scan
AUX and ##:
Select an auxiliary to be activated.
Global = internal and external auxiliaries.
NOTE: The auxiliaries on
the rear panel of the
CM6800 are activated by
global auxiliary numbers 1,
2, and 3
OPTIONS:
GON = turn global auxiliary on (1-128)
GOFF = turn global auxiliary off (1-128)
CON = turn camera auxiliary on (1-8)
COFF = turn camera auxiliary off (1-8)
GROUP ENABLE: Assign the alarm contact to one or more alarm groups (A through H).
OPTIONS:
Y = include in group
N = do not include in group
46
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
Video Loss Alarm
You can program the CM6800 to detect video loss from any camera input and indicate the
loss through alarm mode – the alarm icon and a “V” (for video loss) appear on system
monitors as specified by alarm group assignment.
Use the Video Loss screen to configure the system to display an alarm based on video loss.
PELCO SWITCHER
MODEL CM6800
MAIN MENU
ALARM CONTACTS
VIDEO LOSS MENU
PHYSICAL INPUT:
1
2
3
4
INTERNAL CONTACT
EXTERNAL CONTACT
VIDEO LOSS
1
2
3
4
5
6
7
8
9
CAMERA
ENABLE: OFF
LOGICAL CAMERA
MONITOR
ACCESS
ACK TYPE: MANUAL
CAMERA 0001
TIME OUT: 10
ALARM GROUP
TIME & DATE
PORT
PRIORITY
SEQUENCE
MACRO
RETURN
GROUP ENABLE
A
N
B
N
C
D
E
F
G
H
N
N
N
N
N
N
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
RETURN
ENGLISH
RETURN
00654
00642
00663
Figure 35. Access the Video Loss Screen
PHYSICAL INPUT: Select the physical input number; the logical camera number associ-
ated with the specific physical input appears on the screen below.
ENABLE:
Enable video loss detection for the specific video input by selecting ON
(Default = OFF); to complete the enable process, you must also assign
the alarm contact to an alarm group (refer to the GROUP ENABLE
description).
ACK TYPE:
Select the video loss alarm clearance type.
OPTIONS:
MANUAL = alarm must be acknowledged from a system keyboard
AUTO =
alarm will time out automatically after the interval specified
in the TIME OUT field
TIME OUT:
Enter the amount of time (0-99 seconds) alarm remains active after the
video has been restored (AUTO alarms only).
CAMERA 0001:
The logical camera number associated with the physical input specified
in the PHYSICAL INPUT field appears here.
GROUP ENABLE: Assign the video loss alarm to one or more alarm groups (A through H).
OPTIONS:
Y = include in group
N = do not include in group
Pelco Manual C1515M-A (11/01)
47
Download from Www.Somanuals.com. All Manuals Search And Download.
Alarm Groups
Use the Alarm Group screen to configure alarm groups to appear on system monitors. To
display on a monitor, an alarm must be assigned to an alarm group.
PELCO SWITCHER
MODEL CM6800
MAIN MENU
ALARM CONTACTS
ALARM MONITOR GROUP SETUP
1
2
3
4
INTERNAL CONTACT
EXTERNAL CONTACT
VIDEO LOSS
MON
A
B
C
D
E
F
G
H
1
2
3
4
5
6
7
8
9
CAMERA
LOGICAL CAMERA
MONITOR
ACCESS
01
02
03
04
05
06
07
08
—
—
—
D
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
S
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
ALARM GROUP
TIME & DATE
PORT
PRIORITY
SEQUENCE
MACRO
RETURN
Q
—
—
—
S
S
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
HELP
RETURN
ENGLISH
RETURN
00654
00642
00637
Figure 36. Access the Alarm Group Screen
Specify the display option for up to eight alarm groups (A through H). Refer to the Alarm
Group Display Options in this section. If you make an error in assigning alarm groups, the
message “ERROR IN GROUP” appears.
Display Option Display Option
Number of Monitors Displaying
Each Alarm Group
Entry
Type
B
block build
chronological pair
up to eight
D and Q
M and L
S
one display monitor (D), one queue monitor (Q)
reverse chronological pair one display monitor (M), one queue monitor (L)
salvo switching from two to eight
48
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
AUXILIARY OUTPUTS
The three local auxiliary (AUX) outputs on the rear panel of the CM6800 can be operated
manually from a system keyboard or automatically in response to an alarm.
PELCO SWITCHER
MODEL CM6800
MAIN MENU
SET AUXILIARY MENU
AUX
MODE
ALM
MON
01
DWL
10
43
1
2
3
1
2
3
4
5
6
7
8
9
CAMERA
LAT
02
LOGICAL CAMERA
MONITOR
ACCESS
MOM
03
20
TIME & DATE
PORT
PRIORITY
SEQUENCE
MACRO
RETURN
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
ENGLISH
RETURN
00654
00643
Figure 37. Access the Set Auxiliary Screen
MODE:
For each auxiliary select the operation mode.
OPTIONS:
ALM = activate the auxiliary as a response to an alarm; if you select
this mode, specify the monitor number and dwell time
LAT = latching operation
MOM = momentary operation
Specify values for the MON and DWL fields only when you select ALM in the MODE field.
MON:
DWL:
Specify the number of the monitor the auxiliary will follow (01-08).
Specify the amount of time the auxiliary will remain active after there is
no longer an alarm displayed on a monitor (01-99 seconds). The alarm
is displayed on a monitor until
•
•
the alarm is acknowledged manually (if MANUAL is selected in
the alarm contact ACK TYPE field),
the alarm contact times out (if AUTO is selected in the alarm
contact ACK TYPE field).
Refer to the ACK TYPE description in Internal and External Alarms and
in Video Loss Alarm.
Pelco Manual C1515M-A (11/01)
49
Download from Www.Somanuals.com. All Manuals Search And Download.
CAMERA
Use the Camera screen to configure settings for each camera connected to the CM6800.
PELCO SWITCHER
MODEL CM6800
MAIN MENU
CAMERA 0001
VERTICAL DRIVE:
OFF
CONTROL:
PORT ADDRESS:
EXT COAX
01
1
2
3
4
5
6
7
8
9
CAMERA
LOGICAL CAMERA
MONITOR
ACCESS
CAMERA TITLE:
CAM 1
TIME & DATE
PORT
PRIORITY
SEQUENCE
MACRO
RETURN
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
ENGLISH
RETURN
00654
00646
Figure 38. Access the Camera Screen
CAMERA:
Select the logical number of the camera (video input) to be defined
(0001-9998).
NOTE: To select logical numbers other than the default numbers
(001 to 0048) you must first program the logical numbering in the Logical
Camera screen. Refer to Logical Camera Numbers in this section.
VERTICAL DRIVE: Enable Vertical Drive (ON) to synchronize Pelco cameras that have the
ability to accept a synchronization pulse via the coax cable.
NOTE: The following Pelco
cameras are compatible
with the vertical drive option:
CONTROL:
Select the receiver control type for the device connected to this input;
that is, the type of receiver communication you will use to control a
camera’s pan and tilt and lens (if applicable).
CC3500H-2
CC3500S-2
CC3600H-2
CC3551H-2
MC3600H-2
MC3651H-2
MC3500S-2
OPTIONS:
EXT COAX: Coaxitron extended mode (32-bit)
STD COAX: Coaxitron standard mode (15-bit)
MUX: Genex multiplexer
PTZ-A: RS-422 Control Port A
PTZ-B: RS-422 Control Port B
NOTE: If you select PTZ-A or PTZ-B you must also specify the port
address (in the following field) and program Serial Port 9 or 10 (refer to
Ports in this section).
PORT ADDRESS: Required only for Genex multiplexer or RS-422 control.
Genex multiplexer: Select the address of the multiplexer (01-32); this
address must match the unit ID specified through multiplexer program-
ming. Refer to the MX4000 Genex Series Simplex and Duplex
Multiplexers Installation/Operation Manual.
RS-422 cameras connected through PTZ-A or PTZ-B: Select the
camera/device address for RS-422 control (01-32). The port address
must match the address setting configured through the camera/
receiver DIP switch settings.
CAMERA TITLE:
The camera title (up to 20 alphanumeric characters) appears on the
monitor during real-time camera display (refer to Monitor Display in this
section). Use F1 and F2 to scroll through the characters; once you
reach the desired character for a position, navigate to the next position.
The default characters are 26 upper case letters and the numbers 0-9.
You can add special characters, such as letters with accent marks
used in other languages, through the CM6800-MGR (refer to the
CM6800-MGR Quick Start Guide).
50
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
EVENT TIMERS
You can automate system operation to activate sequences or macros on specific monitors.
Events can be scheduled on a daily or weekly basis, or on a specific date such as a
holiday. If you set more than one timer to start at the same time, the timers will run in the
following order of precedence: weekly, special, daily.
On each event timer screen:
•
•
•
•
Two methods are provided for selecting the event time: scrolling through time values
or entering a valid hour and minute.
Each timer can activate either a macro or a sequence. Select a value for either the
MACRO field or the SEQ field.
A macro started by an event timer runs until the last step is completed (unless you
specify a loop in the macro).
A sequence started by an event timer runs continuously until another sequence or
macro begins, or until a system operator selects a different camera.
Daily Timer
Use the Daily Timer screen to schedule up to 32 daily events.
PELCO SWITCHER
MODEL CM6800
MAIN MENU
DAILY TIMER 01
EVENT TIMER
ENABLE:
TIME:
OFF
12:02
1
2
3
DAILY TIMER
WEEKLY TIMER
SPECIAL TIMER
1
2
3
4
5
6
7
8
9
CAMERA
LOGICAL CAMERA
MONITOR
ACCESS
MACRO 00
MON SEQ
RETURN
TIME & DATE
PORT
PRIORITY
SEQUENCE
MACRO
1
2
3
4
5
6
7
8
00
00
00
00
00
00
00
00
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
ENGLISH
RETURN
RETURN
00654
00648
00647
Figure 39. Access the Daily Timer Screen
DAILY TIMER:
ENABLE:
TIME:
Select the timer number (01-32).
Enable (ON) or disable (OFF) the timer.
Set the hour and minute at which the event is to begin (24-hour time).
To activate a macro, select a valid macro number (01-32).
MACRO:
SEQ:
To activate a sequence, select a valid sequence number (01-16) to run
on a specific monitor.
Pelco Manual C1515M-A (11/01)
51
Download from Www.Somanuals.com. All Manuals Search And Download.
Weekly Timer
Use the Weekly Timer screen to schedule up to 32 weekly events.
PELCO SWITCHER
MODEL CM6800
MAIN MENU
EVENT TIMER
WEEKLY TIMER 01
ENABLE: OFF
1
2
3
DAILY TIMER
WEEKLY TIMER
SPECIAL TIMER
TIME:
SUN MON TUE WED THU FRI
MAC MAC MAC MAC MAC MAC MAC
24 01 01 01 01 01 24
MON SEQ SEQ SEQ SEQ SEQ SEQ SEQ
09:02
1
2
3
4
5
6
7
8
9
CAMERA
SAT
LOGICAL CAMERA
MONITOR
ACCESS
RETURN
TIME & DATE
PORT
PRIORITY
SEQUENCE
MACRO
1
2
3
4
5
6
7
8
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
16
00
00
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
ENGLISH
RETURN
RETURN
00654
00648
00664
Figure 40. Access the Weekly Timer Screen
WEEKLY TIMER: Select the timer number (01-32).
ENABLE:
TIME:
Enable (ON) or disable (OFF) the timer.
Set the hour and minute at which the event is to begin (24-hour time).
MACRO:
To activate a macro, in the column under the desired day of the week,
select a valid macro number (01-32).
SEQ:
To activate a sequence, in the column under the desired day of the
week, select a valid sequence number (01-16) to run on a specific
monitor.
Special Timer
Use the Special Timer screen to schedule up to 32 events on a specific date(s).
PELCO SWITCHER
MODEL CM6800
MAIN MENU
EVENT TIMER
SPECIAL TIMER 32
ENABLE: OFF
TIME: 10:00 DATE: 25-DEC-01
MACRO 00
1
2
3
DAILY TIMER
WEEKLY TIMER
SPECIAL TIMER
1
2
3
4
5
6
7
8
9
CAMERA
LOGICAL CAMERA
MONITOR
ACCESS
RETURN
MON SEQ
TIME & DATE
PORT
PRIORITY
SEQUENCE
MACRO
1
2
3
4
5
6
7
8
01
02
08
08
08
08
08
08
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
ENGLISH
RETURN
RETURN
00654
00648
00661
Figure 41. Access the Special Timer Screen
SPECIAL TIMER: Select the timer number (01-32).
ENABLE:
TIME:
Enable (ON) or disable (OFF) the timer.
Set the hour and minute at which the event is to begin (24-hour time).
Select the date on which the event is to begin (DD-MMM-YY).
To activate a macro, select a valid macro number (01-32).
DATE:
MACRO:
SEQ:
To activate a sequence, select a valid sequence number (01-16) to run
on a specific monitor.
52
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
LOGICAL CAMERA NUMBERS
A logical number is a user-selectable, variable number, and is always associated with an
actual physical input. A physical input number represents an actual BNC input on the rear
panel of the CM6800 and is a fixed number. Within the programming screens and at the
operator level the logical number is the number used for reference.
Example of a logical numbering plan:
Physical input number
Cameras 1-5
Location in store
First floor
Logical number
11-15
Cameras 6-12
Second floor
21-27
Use the Logical Camera screen to assign new logical numbers as appropriate for your
system.
PELCO SWITCHER
MODEL CM6800
MAIN MENU
LOGICAL CAMERA NUMBER MENU
PHY LOG PHY LOG PHY LOG
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
0001 17
0002 18
0003 19
0004 20
0005 21
0006 22
0007 23
0008 24
0009 25
0201 26
0202 27
0203 28
0301 29
0302 30
0303 31
0401 32
0402
0403
0404
0405
0500
0501
0502
0503
0504
0505
0601
0602
0603
0604
0605
0032
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
0033
0034
0035
0036
0037
0038
0039
0040
0041
0042
0043
0044
0045
0046
0047
0048
1
2
3
4
5
6
7
8
9
CAMERA
LOGICAL CAMERA
MONITOR
ACCESS
TIME & DATE
PORT
PRIORITY
SEQUENCE
MACRO
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
ENGLISH
RETURN
RETURN
00654
00652
Figure 42. Access the Logical Camera Number Screen
PHY:
LOG:
The physical input number represents an actual BNC input on the rear
panel of the CM6800 and cannot be changed.
Assign a valid logical number (0001-9998) to each physical camera
input. A valid number is any number from 0001 to 9998 that has not
already been assigned to a physical camera input.
Example: In Figure 43, physical camera input 22 is assigned a
logical number of 0501. To view this camera an operator
will do the following:
1. Enter 501.
2. Press the CAM key.
Using the new logical camera number:
If you change a logical camera number in the programming menus, you cannot control the
camera until you select the camera number from the keyboard:
1. Enter the new logical camera number.
2. Press the CAM key.
The CM6800 automatically updates all other usages of the logical camera number, such as
in sequences and macros.
Pelco Manual C1515M-A (11/01)
53
Download from Www.Somanuals.com. All Manuals Search And Download.
MACROS
Macros simplify operator control by grouping multiple functions into a single command. Use
the Macros screen to program up to 32 system macros.
MACRO MENU
PELCO SWITCHER
MODEL CM6800
MAIN MENU
MACRO 01
STP CMD
HELP
MON DWL
##
CAM
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
SWT
SWT
SWT
SWT
000
000
000
000
0001
0002
0003
0004
0005
0006
0007
0008
0009
0010
0011
0012
0013
0014
0015
0016
0017
0018
01
02
03
04
08
00
00
00
00
00
00
00
00
00
00
00
00
00
01
02
03
04
01
01
01
01
01
01
01
01
01
01
01
01
01
01
1
2
3
4
5
6
7
8
9
CAMERA
LOGICAL CAMERA
MONITOR
ACCESS
PRES 001
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
TIME & DATE
PORT
PRIORITY
SEQUENCE
MACRO
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
ENGLISH
RETURN
NEXT
PREVIOUS
RETURN
00654
00653
Figure 43. Access the Macro Screen
MACRO:
STP:
Select the macro number you want to program (1-32).
Each macro can include up to 72 steps. For each step select entries for
the following fields as necessary:
CMD:
Select a command. In addition, enter a valid number in the
specified additional field(s); for example, if you select
PATT, enter a pattern number in the Command # field, a
camera number in the Camera field, and a monitor
number in the Monitor field.
Refer to Table H in the Appendix for a description of each
command and the additional fields required for each
command.
##:
If applicable, enter a valid number associated with the
command selected.
CAM:
If applicable, enter a logical camera number. To select
logical numbers other than the default numbers (1 to 48),
you must first program the logical numbering in the
Logical Camera window. Refer to the Logical Camera
Numbers section.
MON:
DWL:
If applicable, enter a monitor number.
If desired, enter a dwell time (1-99 seconds); the dwell
time is the period the macro halts before continuing to the
next step. The default dwell time is two seconds.
54
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
MACRO STATUS VIEW SCREEN
The Macro Status View screen provides a status view of each system macro (1-32). For
each active macro the current status (RUN or HOLD) and the number of the next macro
step is displayed. If a macro is not running, the status is IDLE and the step number is 00.
A system operator can display the Macro Status View screen without entering password-
protected programming screens.
MACRO STATUS
MAC
1
2
3
4
5
6
7
8
STATUS STEP
MAC
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
STATUS
HOLD
RUN
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
STEP
00
22
00
00
00
00
00
00
00
00
00
00
00
00
00
00
RUN
IDLE
HOLD
IDLE
RUN
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
01
09
23
00
00
00
00
00
00
00
00
00
00
00
00
00
PELCO VIDEO SWITCHER
MODEL CM6800
PASSWORD TO MAIN MENU
*******
9
SCRATCHPAD SEQUENCE
10
11
12
13
14
15
16
MACRO STATUS VIEW
RETURN
REFRESH
EXIT
Figure 44. Macro Status View Screen
Pelco Manual C1515M-A (11/01)
55
Download from Www.Somanuals.com. All Manuals Search And Download.
MONITOR DISPLAY
Use the Monitor screen to adjust monitor display settings for your system. You can adjust
settings for the current monitor only (CURRENT) or for all system monitors (ALL).
PELCO SWITCHER
MONITOR CURRENT
MODEL CM6800
MAIN MENU
CAMERA NUMBER:
CAMERA TITLE:
R/X TYPE:
MON/ALM NUMBER:
MON/ALM STATUS:
TIME:
ON
ON
ON
ON
ON
ON
ON
8
1
2
3
4
5
6
7
8
9
CAMERA
LOGICAL CAMERA
MONITOR
ACCESS
TIME & DATE
PORT
PRIORITY
SEQUENCE
MACRO
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
DATE:
BRIGHTNESS
POSITION DISPLAY
SET ALL
RETURN
ENGLISH
RETURN
00654
00655
Figure 45. Access the Monitor Screen
MONITOR:
Select CURRENT to program the monitor display for the monitor you
are currently operating or ALL for all monitors connected to the CM6800.
If you select ALL, you must navigate left or right in the SET ALL field to
apply programming changes (refer to the SET ALL field description).
CAMERA NUMBER: Enable (ON) or disable (OFF) on-screen display of the logical camera
number.
00620
CAMERA TITLE:
R/X TYPE:
Enable (ON) or disable (OFF) on-screen display of the camera title
(maximum of 20 alphanumeric characters).
00620
00620
Enable (ON) or disable (OFF) on-screen display of the camera
control type. The letter displayed on the monitor reflects the receiver
control type selected in the CONTROL field on the Camera screen.
R/X TYPE DISPLAY VALUES:
E = Coaxitron extended mode (32-bit)
S = Coaxitron standard mode (15-bit)
M = Genex multiplexer
P = PTZ-P (RS-422 through Control Port PTZ-A or PTZ-B)
D = PTZ-D (RS-422 through Control Port PTZ-A or PTZ-B)
56
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
MON/ALM NUMBER: Enable (ON) or disable (OFF) on-screen display of the monitor/
alarm number. During normal operation, the monitor number
00620
appears in this field. The monitor number is a fixed number,
representing an actual BNC output on the rear panel of the CM6800.
When an alarm is active, the alarm number appears in this field. The
alarm number represents an alarm contact – the physical alarm
input number of an internal alarm contact, or the address of an
external alarm contact as configured on the Alarm Interface Unit.
MON/ALM STATUS: Enable (ON) or disable (OFF) on-screen display of the monitor or
alarm status.
00620
MONITOR STATUS DISPLAY VALUES:
Blank = normal status
H = hold
S = sequence
V
NOTE: If an operator presses the HOLD key while an alarm
appears on the monitor, the H does not appear. The alarm icon and
alarm status value blink to indicate the HOLD status.
0001
0001
E
CAM 1
01-JAN-01 01:01:01
V
ALM STATUS DISPLAY VALUES:
I = internal alarm
00634
E = external alarm
V = video loss alarm
TIME:
Enable (ON) or disable (OFF) on-screen display of the time as
programmed in the system.
00620
DATE:
Enable (ON) or disable (OFF) on-screen display of the date as
programmed in the system.
BRIGHTNESS:
Select the brightness level of the on-screen display (1-8; 8 = white
characters, 1 = black characters; 2-7 = shades of gray).
If you select CURRENT in the MONITOR field, you can see the
brightness level change as you scroll through the options.
If you select ALL in the MONITOR field, the changes do not take
effect until you apply changes in the SET ALL field.
POSITION DISPLAY: Navigate left or right to select the Test Positioning Menu.
The real-time camera display appears with Test Positioning Menu
text superimposed on the screen. Use the position keys or joystick
to move the text to the desired position on the screen. The text
moves one line or character position at a time.
TEST POSITIONING MENU
---
---
PRESS PGM EXIT
00633
Press the PGM key to exit the test positioning menu.
SET ALL:
To apply monitor display changes to all system monitors (if you
selected ALL in the MONITOR field) you must navigate left or right in
the SET ALL field; otherwise monitor display settings are not
changed.
If you selected CURRENT in the MONITOR field, navigating left or
right in the SET ALL field has no effect.
Pelco Manual C1515M-A (11/01)
57
Download from Www.Somanuals.com. All Manuals Search And Download.
PASSWORD
Use the Set Password screen to change the system password.
If you change the password and then forget the new one, you will have to reset the system
to the factory defaults. All system programming will be lost. Pelco recommends uploading
your programming settings to the CM6800-MGR before changing the password. This allows
you to download the previous system settings, in the event of a system reset. If necessary,
refer to the Troubleshooting section for the system reset procedure.
PELCO SWITCHER
SET PASSWORD
MODEL CM6800
MAIN MENU
OLD PASSWORD: *******
NEW PASSWORD: *******
VER PASSWORD: *******
1
2
3
4
5
6
7
8
9
CAMERA
LOGICAL CAMERA
MONITOR
ACCESS
TIME & DATE
PORT
PRIORITY
SEQUENCE
MACRO
RETURN
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
ENGLISH
RETURN
00654
00656
Figure 46. Access the Set Password Screen
OLD PASSWORD:
Enter the current password (Default: 2899100). If you make a mistake
entering the old password, the message “WRONG OLD PASSWORD.
TRY AGAIN!” appears. Re-enter the old password correctly.
NEW PASSWORD: Using the numerical keypad, enter the new password. The password
must be seven digits.
VER PASSWORD:
Enter the new password again as a verification check. If you make a
mistake entering the verification password, the message “VERIFIED
PASSWORD DOESN’T MATCH” appears. Re-enter the verification
password correctly.
Once the new password is accepted, the Main Menu appears.
58
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
PORTS (SERIAL/COM PORTS)
Use the Port screen to configure the settings for each device connected to a Serial/COM
port on the rear panel of the CM6800.
PELCO SWITCHER
SET SERIAL PORT 05
MODEL CM6800
MAIN MENU
DEVICE:
TYPE:
BAUD RATE:
PARITY:
DATA BITS:
STOP BITS:
KBD300
RS485
9600
ODD
8
1
2
3
4
5
6
7
8
9
CAMERA
LOGICAL CAMERA
MONITOR
ACCESS
TIME & DATE
PORT
1
PRIORITY
SEQUENCE
MACRO
RETURN
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
ENGLISH
RETURN
00654
00657
Figure 47. Access the Port Screen
SET SERIAL PORT: Select the number of the desired Serial Port/COM port (01-10).
NOTE: In the programming
screens “KBD300” is used
to refer to the KBD100,
KBD200, and KBD300
keyboards.
The serial port numbers correspond to the communication ports on
the CM6800 rear panel as follows:
Serial Port
Input on CM6800 rear panel
01
COM 1
NOTE: COM 1 can be accessed through a DB9
input or an RJ-45 port.
02-08
09
COM 2-8 RJ-45 inputs
PTZ-A control input
PTZ-B control input
10
DEVICE:
TYPE:
Select the device connected to the COM port; the values in the
TYPE, BAUD RATE, PARITY, DATA BITS, and STOP BITS fields
change to the settings appropriate for the specific device.
If necessary, and if allowed, select the desired communication type
(RS-232, RS-422, or RS-485).
BAUD RATE:
PARITY:
Select the desired baud rate.
Select the desired parity type.
This value cannot be changed.
This value cannot be changed.
DATA BITS:
STOP BITS:
Pelco Manual C1515M-A (11/01)
59
Download from Www.Somanuals.com. All Manuals Search And Download.
PRIORITY CONTROL
The CM6800 provides eight levels of priority control. Each level defines the ability of a
keyboard to control a pan/tilt/zoom (camera positioning system) and to access program-
ming screens.
Priority level applies system wide; a keyboard assigned priority level 2 on COM port 8 has a
higher priority than a keyboard assigned priority level 4 on COM port 5. A higher level
keyboard takes precedence over a lower level keyboard when the keyboards are issuing
control commands.
PELCO SWITCHER
KEYBOARD PRIORITY MENU
MODEL CM6800
MAIN MENU
PORT 05
1
2
3
4
5
6
7
8
9
CAMERA
KBD
PRIORITY
LOGICAL CAMERA
MONITOR
ACCESS
1
2
3
4
5
6
7
8
01
02
08
08
08
08
08
08
TIME & DATE
PORT
PRIORITY
SEQUENCE
MACRO
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
RETURN
ENGLISH
RETURN
00654
00658
Figure 48. Access the Priority Screen
PORT:
Select the COM port number for which you are programming priority
control.
NOTE: You can connect
only one ASCII keyboard/de-
vice per port on the CM6800
(COM port 1, 2, 4, 7, or 8).
For ASCII keyboards priority
control is based on the entry
for keyboard 1.
PRIORITY:
For each keyboard connected to the specified port, assign a priority level
(01-08).
OPTIONS:
Level 1 = highest priority
Level 8 = lowest priority
Levels 1 - 4 have the ability to access programming screens. Levels
5-8 cannot access programming screens. The lowest level or
keyboards located at the same level will access devices on first-come,
first-served basis.
60
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
SEQUENCES
The CM6800 provides two types of sequences:
•
•
An operator can program a scratchpad sequence from an individual monitor, without
accessing password-protected programming screens.
System sequences are password-protected and can run on any system monitor.
PELCO SWITCHER
MODEL CM6800
MAIN MENU
SEQUENCE 01
STP CAM DWL CMD
HELP
##
01
01
00
00
04
AUX
CON
CON
##
000
000
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
0001
0002
0003
0004
0005
0006
0006
0006
0006
0006
0006
0006
0006
0006
0006
0006
0006
0006
02
02
03
02
08
02
02
02
02
02
02
02
02
02
02
02
02
02
PATT
PRES
SSCN
FSCN
PRES
1
2
3
4
5
6
7
8
9
CAMERA
— — — —000
— — — —000
COFF 000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
LOGICAL CAMERA
MONITOR
ACCESS
— — — — 00
— — — — 00
— — — — 00
— — — — 00
— — — — 00
— — — — 00
— — — — 00
— — — — 00
— — — — 00
— — — — 00
— — — — 00
— — — — 00
— — — — 00
TIME & DATE
PORT
PRIORITY
SEQUENCE
MACRO
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
ENGLISH
RETURN
NEXT
PREVIOUS
RETURN
00654
00660
Figure 49. Access the Sequence Screen
SCRATCHPAD SEQUENCE MON ##
STP CAM
DWL
CMD
PATT
PRES
FSCN
RSCN
SSCN
— — — — 00
— — — — 00
— — — — 00
— — — — 00
— — — — 00
— — — — 00
— — — — 00
— — — — 00
— — — — 00
— — — — 00
— — — — 00
— — — — 00
— — — — 00
##
AUX
CON
##
001
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
0001
0005
0008
0012
0023
0006
0007
0008
0009
0010
0011
0012
0013
0014
0015
0016
0017
0018
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
12
00
00
00
PELCO VIDEO SWITCHER
MODEL CM6800
GOFF 101
CON
008
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
— — — —000
PASSWORD TO MAIN MENU
*******
SCRATCHPAD SEQUENCE
RETURN
HELP
00619
NEXT
PREVIOUS
RETURN
00659
Figure 50. Access the Scratchpad Sequence Screen
SEQUENCE:
STP:
Select the sequence number you want to program (1-16).
Each sequence can include up to 72 steps. For each step select
entries for the following fields as necessary:
CAM:
Enter the desired camera number (logical number).
Enter the dwell time (01-99 seconds).
DWL:
CMD and ##:
Select a command; if you select a pattern or a
preset enter a valid pattern or preset number.
OPTIONS:
PRES = preset
PATT = pattern
RSCN = random scan
FSCN = frame scan
SSCN = stop scan
AUX and ##:
Select an auxiliary to be activated.
Global = internal and external auxiliaries.
NOTE: The auxiliaries on
the rear panel of the
CM6800 are activated by
global auxiliary numbers 1,
2, and 3.
OPTIONS:
GON = turn global auxiliary on (1-128)
GOFF = turn global auxiliary off (1-128)
CON = turn camera auxiliary on (1-8)
COFF = turn camera auxiliary off (1-8)
Pelco Manual C1515M-A (11/01)
61
Download from Www.Somanuals.com. All Manuals Search And Download.
TIME AND DATE
Use the Time and Date screen to set the system time and date settings. The time and date
displayed on the monitor during real-time camera display is the time set in the memory
through this screen. The system time and date information is kept current in battery-backed
RAM. New time and date information will be set when you apply the changes (refer to the
SET TIME & DATE field description).
PELCO SWITCHER
SET TIME & DATE
MODEL CM6800
MAIN MENU
SET
MM DD YY
01 / 01 / 01
01 : 01 : 01
1
2
3
4
5
6
7
8
9
CAMERA
DATE:
TIME:
LOGICAL CAMERA
MONITOR
ACCESS
TIME & DATE
PORT
PRIORITY
SEQUENCE
MACRO
DISPLAY AS
FORMAT: DD/MMM/YY
STYLE: 24Hr
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
SET TIME & DATE
RETURN
ENGLISH
RETURN
00654
00662
Figure 51. Access the Time and Date Screen
DATE:
TIME:
Select or enter the month, day, and year of the desired system date.
Select or enter the hour, minute, and second of the desired system
time.
FORMAT:
Select the on-screen date format.
OPTIONS:
DD/MMM/YY
MMM/DD/YY
YY/MMM/DD
DD/MM/YY
MM/DD/YY
YY/MM/DD
STYLE:
Select the on-screen time format. This setting affects the on-screen
time displayed on system monitors only. System functions pro-
grammed through the event timers (refer to Event Timers in this
section) are based on 24-hour time settings.
OPTIONS:
24Hr
AM/PM (12 Hr)
SET TIME & DATE: You must navigate left or right in the SET TIME & DATE field to
apply the changes.
PATTERNS, PRESETS, AND ZONES
Special characters added through the CM6800-MGR may not be available with your
camera positioning system. Preset, pattern, and zone labels containing special characters
will appear on the monitor with blanks in place of the special characters.
Refer to the Operation section for instructions on creating patterns. Refer to your keyboard
manual for instructions on programming presets and zones.
62
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION
OVERVIEW
A brief description of CM6800 operation is provided here. Refer to the following sections for
detailed instructions and options.
Install the CM6800 and
Refer to the Installation section.
connect all system devices.
Power-up the system.
Switch monitor.
Refer to the System Start-up section.
1. Enter the monitor number.
2. Press the MON key.
Select camera.
1. Enter the camera number.
2. Press the CAM key.
Control PTZ receivers.
Use the appropriate PTZ control keys or joystick
(depending on the keyboard used).
Extended Coaxitron protocol receivers can be operated
without any programming changes. Other receiver
control protocols require programming changes.
Call a preset.
Program the preset through the keyboard.
1. Enter the preset number.
2. Press the PRESET key or Prst/Lock key
(depending on the keyboard used).
System does not function.
Refer to the Troubleshooting section.
OPERATING THE CM6800
The CM6800 can be operated with a KBD100, KBD200, KBD300, KBD960, or KBR960
keyboard. Operation instructions are provided below, but you should become familiar with
the detailed instructions provided in the appropriate keyboard manual.
The CM6800 can also be controlled with ASCII commands. Refer to the ASCII Operating
Commands section.
SWITCH MONITORS
If you select a restricted monitor, the monitor does not switch; the keyboard LED displays
the previously selected monitor number.
ALL KEYBOARDS
1. Enter the monitor number.
2. Press the MON key. The keyboard LED displays the selected monitor number.
Pelco Manual C1515M-A (11/01)
63
Download from Www.Somanuals.com. All Manuals Search And Download.
SELECT CAMERAS
If you select a restricted camera view, the camera view does not appear on that monitor.
The previously selected, unrestricted camera view remains on the monitor.
KBD100/200/300 KEYBOARDS
KBD960/KBR960 KEYBOARDS
1. Enter the camera number.
2. Press the CAM key.
1. Enter the camera number.
2. Press the CAM key.
OR
Press the PREV or NEXT key to scroll
through the available cameras.
OR
Press the BWD or FWD key to scroll
through the available cameras.
OR
From the Camera Menu, select
or
to scroll through the available
cameras.
CONTROL RECEIVERS
Select a suitable camera and operate a PTZ function. A keyboard with “view-only” access
can view the signal from the specified camera but cannot control the camera.
Extended Coaxitron protocol receivers can be operated without any programming changes.
Other receiver control protocols require programming changes. Refer to the Programming
section.
Receiver control is not available with the KBD100 keyboard.
KBD200 KEYBOARD
Pan/Tilt/Zoom
Lens Control: Focus, Iris
Press and hold the appropriate pan/tilt key until
the camera reaches the desired position. To
change the speed of movement, press a number
(1-9) key first (1=slowest, 9=fastest).
Press and hold the appropriate
lens control key until the desired
effect is seen. To change the
speed of focus, press a number
(1-4) key, and then press the
FAR key (1=slowest, 4=fastest).
Press and hold the appropriate zoom key until
the desired effect is seen. To change the speed
of zoom, press a number (1-4) key and then
press the WIDE key (1=slowest, 4=fastest).
KBD300 KEYBOARD
Pan/Tilt/Zoom
Lens Control: Focus, Iris
Move the joystick until the camera reaches the
desired position. To increase the speed of
movement, move the joystick farther from center.
Press and hold the appropriate
lens control key until the desired
effect is seen. To change the
speed of focus, press a number
(1-4) key, and then press the
FAR key (1=slowest, 4=fastest).
Twist the joystick clockwise to zoom in,
counterclockwise to zoom out. To change the
speed of zoom, press a number (1-4) key and
then twist the joystick (1=slowest, 4=fastest).
64
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
KBD960/KBR960 KEYBOARDS
Pan/Tilt/Zoom
Lens Control: Focus, Iris
Move the joystick until the camera reaches the
desired position. To increase the speed of
movement, move the joystick farther from
center or press the T key to pan at turbo speed.
Use the NEAR/FAR key to focus
near or far.
Use the OPEN/CLS key to open
or close the iris.
Twist the joystick clockwise to zoom in,
counterclockwise to zoom out. Or use the IN/
OUT key to zoom in or out.
OPERATE SEQUENCES
You can run a scratchpad sequence from an individual monitor or a system sequence on
any monitor accessible from the keyboard. When running a sequence, any cameras not
accessible to the keyboard will be bypassed.
KBD100/200/300 KEYBOARDS
Run a Sequence
KBD960/KBR960 KEYBOARDS
Run a Sequence
1. Enter a sequence number (1-16). Skip
this step to run a scratchpad sequence.
1. Select
.
2. Enter a sequence number (1-16
for a system sequence; 0 for the
scratchpad sequence).
2. Press and hold the NEXT or PREV key
to move forward or backward through
the sequence.
SEQ
To move through the sequence one
camera at a time:
3. Select
to start the sequence.
OR
Press the NEXT key to move forward.
Press the PREV key to move backward.
1. Select
.
SEQ
Pause a Sequence
2. Select
Menu.
to enter the Sequence
1. Press the HOLD key; monitor displays H.
2. Press the HOLD key to resume.
3. Enter a sequence number (1-16).
OR
Stop a Sequence
Select
or
to scroll
1. Enter a camera number.
2. Press the CAM key.
through available sequences.
to start the
4. Select
sequence.
or
NOTE: You can define a function key
to run a sequence. Refer to the
KBD960 Keyboard Installation/
Operation Manual for instructions.
Pause a Sequence
1. Select
2. Select
.
or
to resume.
Stop a Sequence
1. Select
.
OR
1. Enter a camera number.
2. Press the CAM key.
Pelco Manual C1515M-A (11/01)
65
Download from Www.Somanuals.com. All Manuals Search And Download.
RUN A MACRO
KBD100/200/300 KEYBOARDS
Run a Macro
KBD960/KBR960 KEYBOARDS
Run a Macro
1. Enter the macro number.
2. Press the MACRO key.
1. Select
.
2. Enter a macro number.
Stop a Macro
MAC
macro.
Macro
3. Select
to start the
1. Enter the number of the running
macro.
OR
2. Press the MACRO key.
1. Select
.
MAC
2. Select
Menu.
to enter the
3. Enter a macro number.
OR
Select
or
to scroll
through available macros.
4. Select
macro.
or
to start the
NOTE: You can define a function key
to run a macro. Refer to the KBD960
Keyboard Installation/Operation
Manual for instructions.
Pause a Macro
1. Select
2. Select
.
or
to resume.
Stop a Macro
1. Select
.
OR
1. Enter a camera number.
2. Press the CAM key.
66
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
ACKNOWLEDGE AN ALARM
When an alarm is triggered, an alarm icon appears on the monitors programmed to show
that alarm.
KBD100/200/300 KEYBOARDS
KBD960/KBR960 KEYBOARDS
1. Enter the monitor number.
2. Press the MON key.
1. Select
2. Select
.
to reset the alarm on
3. Press the ACK key. The alarm is
removed from the selected monitor.
the individual monitor.
4. Repeat for each alarm.
OR
Select
to reset the alarm on
all monitors.
You can also select
alarm.
to mute the
NOTE: You can define a function key
to acknowledge an alarm. Refer to
the KBD960 Keyboard Installation/
Operation Manual for instructions.
CALL A PRESET
Program the preset through the keyboard. Refer to the appropriate keyboard manual for
instructions. Presets are not available with the KBD100 keyboard.
KBD200/300 KEYBOARDS
KBD960/KBR960 KEYBOARDS
1. Enter the preset number.
2. Press the PRESET key.
1. Enter the preset number.
2. Press the Prst/Lock key.
OR
Select the PRST icon.
Pelco Manual C1515M-A (11/01)
67
Download from Www.Somanuals.com. All Manuals Search And Download.
CREATE AND RUN A PATTERN
Patterns are not available with the KBD100 keyboard.
KBD200/300 KEYBOARDS
Create a Long Pattern
KBD960/KBR960 KEYBOARDS
Refer to the KBD960 Keyboard
Installation/Operation manual for
instructions on creating a pattern.
1. Enter a camera number.
2. Enter 1.
3. Press and hold the PATTERN key for
two seconds.
PRST
1. Select
Menu.
to display the Preset
4. The monitor will indicate the program-
ming function is active. Move the camera
position as desired for the pattern.
2. Select
to start a pattern.
5. Press the ACK key to close the
programming function.
OR
PRST
1. Select
Menu.
to display the Preset
to run the first pattern
Create a Shart Pattern
1. Enter a camera number.
2. Enter the short pattern number (2 or 3).
2. Enter 1.
3. Select
3. Press and hold the PATTERN key for
two seconds.
4. The monitor will indicate the program-
ming function is active. Move the camera
position as desired for the pattern.
of previously defined half-patterns.
OR
5. Press the ACK key to close the
programming function.
PRST
1. Select
Menu.
to display the Preset
Run a Long Pattern
1. Enter 1.
2. Enter 2.
3. Select
2. Press the PATTERN key.
to run the second
3. Move the joystick or call a preset to
stop the pattern.
pattern of previously defined
half-patterns.
Run a Short Pattern
1. Enter the short pattern number (2 or 3).
2. Press the PATTERN key.
3. Move the joystick or call a preset to
stop the pattern.
OPERATE AUXILIARIES/RELAYS
Local auxiliaries are the outputs on the rear panel of the CM6800. External auxiliaries are
available by connecting an REL2064 Relay Interface Unit to the CM6800 through COM port 3.
Operate a Local Auxiliary
KBD100/200/300 KEYBOARDS
KBD960/KBR960 KEYBOARDS
Auxiliary 1 relay: Press F1 to activate/
deactivate.
Auxiliary 1 relay: Press F12* to
activate/deactivate.
Auxiliary 2 TTL output: Press F2 to
activate/deactivate.
Auxiliary 2 TTL output: Press F24* to
activate/deactivate.
* F12 and F24 are the default auxiliary
control function keys; user-selected
function keys can be defined through the
Key Define Menu. Refer to the KBD960
Keyboard Installation/Operation Manual
for instructions.
NOTE: If you connect REL2064 Relay
Interface Units (up to two) to the
CM6800, operation of the two relays on
the rear panel of the CM6800-32X6 will
also operate the first two relays on the
first external unit (unless you number
the external relays starting at 64).
68
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
Operate an External Auxiliary
The CM6800 can control up to two REL2064 Relay Interface Units connected to the
system. Each unit provides 64 relays. Refer to the REL2064 Relay Interface Unit
Installation/Operation Manual for detailed information. External relays cannot be operated
with the KBD100.
KBD200/300 KEYBOARD
KBD960/KBR960 KEYBOARDS
The KBD200/300 keyboards (firmware
version 4.2 and later) can operate external
relays.
1. Enter the GPI number for the
appropriate relay output.
GPI
Refer to the KBD200 Keyboard Installation/
Operation Manual or the KBD300
Keyboard Installation/Operation Manual for
instructions.
2. Press
.
3. Press the desired AUX number
icon to activate the relay and
associated peripheral device.
NOTE: External relays cannot be operated
with KBD200/300 keyboard firmware
versions prior to 4.2.
(Press
to access AUX 5-8.)
MTRY
4. If
is highlighted, the operation
MTRY
is momentary. If
is not
highlighted, the operation is
latching. Refer to the KBD960
Keyboard Installation/Operation
Manual for instructions.
Operate an Auxiliary in a Receiver
Auxiliary control is not available with the KBD100.
KBD200/300 KEYBOARDS
KBD960/KBR960 KEYBOARDS
Press F4 to activate.
1
From the Camera Menu, press
,
Press F5 to deactivate.
OR
and then release to control an AUX 1
momentary function on the selected
camera.
To control a momentary function:
1. Enter the auxiliary number.
2. Press and hold F4, and then release.
2
Press
to control an AUX 2
momentary function. Press
to
3
8
access
through
.
Pelco Manual C1515M-A (11/01)
69
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTROL GENEX MULTIPLEXER AND GENEX MULTIPLEXER
DISPLAYS
Multiplexer control is not available with the KBD100.
KBD200/300 KEYBOARDS
KBD960/KBR960 KEYBOARDS
1. Enter the number of the multiplexer
input.
MUX
1. Press
to access the MUX
Control Menu.
2. Press the CAM key.
3. Press the SHIFT key. When the
SHIFT LED is lit, the keyboard can be
used to operate the following Genex
multiplexer function keys:
2. Press
or
to scroll through
the available MUX camera numbers.
MUX
MUX
3. Press
if necessary.
must
F1: Digital zoom
F2: PIP display
be highlighted before the system
can control Genex Multiplexer
functions.
F3: Quad display
F4: 9-screen display
F5: 16-screen display
To select a camera through the
multiplexer:
4. Move the joystick or press the
appropriate MUX control icons as
necessary for multiplexer opera-
tion. Refer to the KBD960
Keyboard Installation/Operation
Manual for detailed operation
instructions.
a. Enter the desired camera number
(1-16, based on the camera
assignments set through the
multiplexer).
b. Press the CAM key.
4. Press the SHIFT key to return to
normal keyboard operation.
When the SHIFT LED is off, you can
control the currently selected PTZ
camera through the multiplexer.
To return to camera selection
controlled by the CM6800:
a. Select the desired camera number.
b. Press the CAM key.
c. Move the joystick as necessary.
OPERATE SCANNING FUNCTIONS
Operation of the scanning functions depends on the kind of receiver or pan/tilt mechanism
you have. Refer to the appropriate keyboard manual for detailed instructions on operating
scanning functions.
DETECT VIDEO LOSS
The CM6800 detects video loss from any system camera. If video is lost from a camera,
the CM6800 blue screen appears on any monitor viewing that camera. When video is
restored to that camera, the camera view appears on the monitor(s) again. If the system is
programmed for a video loss alarm, the alarm icon appears.
DEFINE ZONES
A zone is a user-defined, physical location to which (1) a label is attached and (2) a camera
is associated. When the associated camera is panned through or remains within this
defined zone the zone label appears on the monitor.
Refer to the appropriate keyboard manual for detailed instructions on defining zones.
70
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX
CM6800 DIP SWITCHES
00621
Figure 52. CM6800 DIP Switches – Factory Default Settings
Table G. CM6800 DIP Switch Settings
CM6800 DIP Switch
Factory Default
SW1
SW2
SW3
SW4
SW5
SW6
SW7
OFF (0) = NTSC
ON (1) = PAL
CM6800-48X8: OFF
CM6800-48X8-X: ON
RESERVED – must be in the OFF position for
proper operation
OFF
OFF
ON
RESERVED – must be in the OFF position for
proper operation
RESERVED – must be in the ON position for
proper operation
RESERVED – must be in the OFF position for
proper operation
OFF
OFF
OFF
RESERVED – must be in the OFF position for
proper operation
SOFTWARE RESET TO FACTORY DEFAULTS
CAUTION: Resetting the software restores
the system to default settings. All user
programming is lost.
SW8
RESERVED – must be in the OFF position for
proper operation
OFF
Pelco Manual C1515M-A (11/01)
71
Download from Www.Somanuals.com. All Manuals Search And Download.
MACRO COMMANDS
Table H provides a description of each macro command and the additional fields required
for each command. Refer to the Macro section for instructions on programming macros.
Table H. Macro Commands
Command
GON
Description
Specify
Field(s)
Activate an auxiliary.
Turn off an auxiliary.
Auxiliary (1-128)
Auxiliary (1-128)
Command #
Command #
GOFF
Auxiliary Notes:
•
•
“Global” includes both internal and external auxiliaries.
Auxiliaries on the rear panel of the CM6800-32X6 Matrix Switcher are activated by global auxiliary numbers 1, 2 and 3.
CON
Activate a camera auxiliary.
Camera auxiliary (1-8)
Camera (1-48)
Command #
Camera
Monitor (1-8)
Monitor
COFF
Turn off a camera auxiliary.
Camera auxiliary (1-8)
Camera (1-48)
Command #
Camera
Monitor (1-8)
Monitor
SEQ
Start a sequence.
Sequence (1-16)
Monitor (1-8)
Command #
Monitor
SWT
COPY
Switch a camera to a monitor.
Copy a camera view to a monitor.
Camera (1-48)
Camera
Monitor (1-8)
Monitor
Monitor (1-8) to copy from
Monitor (1-8) to copy to
Step (1-72)
Command #
Monitor
GO TO
LOOP
Go to step number specified.
Loop a macro.
Command #
Command #
0 = loop continuously
1-999 = loop the specified
number of times
MACR
?AUX
Start a specific macro.
Macro (1-32)
Command #
Command #
Check a local auxiliary; if the auxiliary is active, the
next step is executed; if the auxiliary is not active,
the next step is skipped.
Local auxiliary (1-3)
END
Exit the macro; no further steps are executed.
None
None
MSWT
Switch a camera connected through the multiplexer. Camera to switch (1-16)ꢀ
Command #
Camera
Multiplexer input (1-48)
Monitor (1-8)
Monitor
PIPB
PIPF
Display multiplexer picture-in-picture view with the
designated camera in the background.
Background camera (1-16)ꢀ
Multiplexer input (1-48)
Monitor (1-8)
Command #
Camera
Monitor
Display multiplexer picture-in-picture view with the
designated camera in the foreground.
Foreground camera (1-16)ꢀ
Multiplexer input (1-48)
Monitor (1-8)
Command #
Camera
Monitor
ꢀ For multiplexer functions, the camera number is the number of the video input on the multiplexer.
The multiplexer input number is the number of the video input on the rear panel of the CM6800.
(Continued on next page)
72
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
Table H. Macro Commands (Continued)
Command
Description
Specify
Field(s)
PIPO
Turn off multiplexer picture-in-picture view.
Multiplexer input (1-48)
Monitor (1-8)
Camera
Monitor
QUAD
NANO
Display multiplexer four-camera mode.
Camera group (1-4)*
Multiplexer input (1-48)
Monitor (1-8)
Command #
Camera
Monitor
Display multiplexer nine-camera mode.
Camera group (1-3)*
Multiplexer input (1-48)
Monitor (1-8)
Command #
Camera
Monitor
HEX
Display multiplexer sixteen-camera mode.
Zoom multiplexer camera view.
Multiplexer input (1-48)
Monitor (1-8)
Camera
Monitor
ZOOM
1 = zoom once
2 = zoom twice
Command #
Multiplexer input (1-48)
Monitor (1-8)
Camera
Monitor
AAI
Arm internal alarm.
Internal alarm (1-8)
Internal alarm (1-8)
External alarm (1-128)
External alarm (1-128)
Command #
Command #
Command #
Command #
Command #
DAI
Disarm internal alarm.
AAE
DAE
AAV
Arm external alarm.
Disarm external alarm.
Arm video loss detection for a camera.
Physical camera number (1-32)
OR
Logical camera number
Camera
DAV
Disarm video loss detection for a camera.
Start a pattern.
Physical camera number (1-32)
OR
Command #
Logical camera number
Camera
Command #
Camera
Monitor
PATT
Pattern (#)**
Camera (1-48)
Monitor (1-8)
Preset (#)**
PRES
Start a preset.
Command #
Camera
Monitor
Camera (1-48)
Monitor (1-8)
Camera (1-48)
Monitor (1-8)
Camera (1-48)
Monitor (1-8)
Camera (1-48)
Monitor (1-8)
RSCN
FSCN
SSCN
Start a random scan.
Start a frame scan.
Stop a scan.
Camera
Monitor
Camera
Monitor
Camera
Monitor
* Refer to the MX4000 Genex Series Simplex and Duplex Multiplexers Installation/Operation Manual for information on multiple
camera displays.
** The number of patterns and presets available is determined by the camera positioning system. Refer to the appropriate camera
positioning system manual.
Pelco Manual C1515M-A (11/01)
73
Download from Www.Somanuals.com. All Manuals Search And Download.
ASCII OPERATING COMMANDS
ASCII protocol uses the ASCII character set to transmit and receive commands between a
personal computer (PC) and the CM6800. The commands are readable but are not English.
ASCII commands control the pan and tilt mechanisms (fixed and variable speed), camera
functions, auxiliary relays, and alarms.
The ASCII protocol communicates in a standard asynchronous, byte-oriented protocol that
includes: 1 start bit, 8 data bits, 1 parity bit (odd parity), and 1 stop bit. The default
communication rate is 9600 baud.
A lowercase “a” ends each command. The ASCII translator acknowledges accepted
commands and rejected commands with the following responses:
AKa
NAa
command accepted
command rejected or the ASCII translator does not recognize the command
If the command requires a numeric value, enter the number first.
Table I provides examples of ASCII commands. Table J lists all of the commands.
Table I. Examples of ASCII Commands
Functional Procedure
Commands
Result
Select a pan and tilt
device labeled
3Ma16#a
Switch camera 16 to currently selected
monitor 3.
“CAMERA # 16” and
switch it to monitor # 3.
Manipulate the pan
and tilt device.
1Ma3#a
Switch camera 3 to monitor 1.
5Ma2#a3\a
47Ra33Da
sa
Go to camera 2, preset 3, on monitor 5.
Pan right at speed 47, tilt down at speed 33.
Stop all image motion.
Switch a camera.
Call a preset.
Pan and tilt.
1Ma3#a
Switch camera 3 to monitor 1.
5Ma2#a3\a
47Ra33Da
Go to camera 2, preset 3, on monitor 5.
Pan right at speed 47, tilt down at speed 33.
74
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
Table J. ASCII Commands
Number ranges are enclosed in brackets – do not enter the brackets. When you control a fixed speed pan and tilt, omit the speed
information.
Result
Desired Action
Command
Calls a monitor to use for camera operation.
Select monitor
[1-9999]Ma
Selects a camera to display on the current operating monitor. The
NEXT key (+) and PREV key (-) commands switch to the next
numbered camera in the system.
Select camera
Next camera
Previous camera
[1-9999]#a
+a
-a
Starts the selected sequence going forward (incrementing camera
numbers).
Start a sequence forward
Start a sequence backward
Hold a sequence
[1-99]qa
[1-99]ba
ea
Starts the selected sequence going backward (decrementing camera
numbers).
Places the running sequence on hold, freezing the currently selected
camera on the monitor. It lets you control the camera or switch. The
sequence is still “armed” on the monitor, but inactive.
Places the running macro on hold.
Hold a macro
[1-32]ea
Moves the currently selected pan and tilt device left or right at the speed
indicated. If you omit the speed, some devices move at their default
speed and others move at their slowest possible speed. Speed
information has no effect on fixed speed devices.
Pan left
Pan right
Stop pan left
Stop pan right
[1-64]La
[1-64]Ra
~La
~Ra
Moves the currently selected pan and tilt device up or down at the
speed indicated. If you omit the speed, some devices move at their
default speed and others move at their slowest possible speed. Speed
information has no effect on fixed speed devices.
Tilt up
[1-63]Ua
[1-63]Da
~Ua
Tilt down
Stop tilt up
Stop tilt down
~Da
Makes the currently selected camera zoom in (close up view) or zoom
out (wide view).
Zoom telephoto
Zoom wide
Stop zoom telephoto
Stop zoom wide
Ta
Wa
~Ta
~Wa
Changes the good focus range nearer or farther on the currently
selected camera.
Focus near
Focus far
Na
Fa
Stop focus near
Stop focus far
~Na
~Fa
Opens (brighter image) or closes (darker image) the iris on the
currently selected camera.
Iris open
Iris close
Oa
Ca
Stop iris open
Stop iris close
~Oa
~Ca
Stops all image motion (stops pan, tilt, zoom, focus, and iris). Does not
stop a pattern.
Stop all PTZ motion
sa
On receivers that do patterns, these commands let you record your
motions and operations (for a limited time) and then have the system
repeat them.
Record pattern
Execute pattern
End pattern
[1-99]/a
[1-99]pa
[1-99]na
Recalls a stored preset position.
Go to preset position
Set preset with a label
[1-99]\a
Sets a preset location with an embedded label, where the ASCII string
must be UPPERCASE characters.
la[string]!a
[1-9999]^a
The [string] is an alphanumeric label up to 20 characters long and
[1-9999] is the associated preset number.
NOTE: All transmitted characters must be ASCII.
Sets a preset location without an embedded label.
Begins a zone without a label.
Set preset without a label
Begin zone
[1-9999]-^a
[1-8](
Begins a zone with an embedded label. The ASCII string must be
uppercase characters.
Begin zone with a label
la[string]!a[1-8](
Ends the zone program
End zone
[1-8])
These commands start and stop scans.
Begin random scan
Begin frame scan
Stop scan
1@
2@
~@
(Continued on next page)
Pelco Manual C1515M-A (11/01)
75
Download from Www.Somanuals.com. All Manuals Search And Download.
Table J. ASCII Commands (Continued)
Command
Result
Desired Action
[1-128]xa
[1-128]~xa
Auxiliaries are relay outputs that can be controlled through the protocol 1-3
operate the AUX 1-2 and F3 auxiliaries on the rear panel of the CM6800
(and the first three auxiliaries on an external REL2064). 4-128 operate the
external auxiliaries on up to two REL2064 Relay Interface Units.
Auxiliary on
Auxiliary off
[1-8]Aa
[1-8]Ba
Operates auxiliaries at the camera (receiver).
Camera auxiliary on
Camera auxiliary off
[1-32]Sa
[1-32]Ha
[1-9999]Ia
Starts the selected macro.
Start macro
Stops the selected macro.
Stop macro
Acknowledges an existing alarm.
These commands arm and disarm system alarms.
Acknowledge alarm
[1-8]Ji
Arm internal alarm
[1-128]Je
[1-48]Jv
[1-8]~Ji
[1-128]~Je
[1-48]~Jv
Arm external alarm
Arm video loss alarm
Disarm internal alarm
Disarm external alarm
Disarm video loss alarm
[1-48]Ya[string]!a
Sends a camera title to the matrix switching system. You can only send
one camera title at a time.
Send camera title
Valid characters in the string are A-Z, a-z, space, and 0-9 in ASCII
representation. Strings are limited to 20 characters.
va
Returns the version number of the device.
Version
ZaMM/DD/YY/HH:
MM:Ssa
Sets the date and time. Since the date and time string could be
confused with other commands, the command Za comes first. This puts
the receiving device into a mode that can accept the specialized string.
Set date and time
NOTE: All transmitted characters must be ASCII.
76
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
NOTE: There are no user-
serviceable parts inside the
CM6800. Only authorized
service personnel may open
the unit.
GAINING INITIAL CONTROL
If you are having problems gaining control of your system for the first time:
•
•
Confirm that all system equipment is plugged in and has power.
Confirm that each keyboard and peripheral device in your system has a unique local
address. Refer to the Switch Settings section in the appropriate keyboard manual.
•
•
Be sure data cables have not been mixed up.
Cycle the data cable to the keyboard:
1. Unplug the data cable from the rear of the keyboard.
2. Plug the data cable back into the rear of the keyboard.
3. WAIT AT LEAST FIVE SECONDS.
4. Select a monitor.
If you still cannot gain control of the system:
•
Confirm the wiring is correct and the user-supplied cable between wall jacks is
appropriate for the application.
•
Confirm that when the keyboard data cable is cycled, the keyboard LED flashes
momentarily (indicating power).
If you still cannot gain control of the system, call Pelco’s 24-hour technical support at
1-800-289-9100 or 1-559-292-1981.
SOFTWARE RESET
Pelco strongly recommends uploading
CAUTION:
Resetting the soft-
ware restores the
system settings to the CM6800-MGR before
the software reset – this will allow you to
restore system settings after the software
reset.
ALARM
1
2
3
4
5
6
7
8
system to default settings.
CONTROL
PTZ
7
8
A
T
+
T
-
R
+
R
T
+
T
R
+
R
B
-
-
-
1. Remove the two screws and the DIP
switch cover plate from the rear of the
switcher.
OUT
F
3
1
2
COM
1
2. Move DIP switch 7 to the ON position
(to “0”).
120/230~
50/60 HZ
25 WATTS
3. Cycle power.
00623
DIP SWITCH
COVER PLATE
The switcher will go through a
software clear cycle and reset to
factory defaults.
Figure 53. DIP Switch Cover Plate
4. Move DIP switch 7 to the OFF position.
Failure to move DIP switch 7 to the
OFF position could result in loss of
system settings during a power
outage.
00622
5. Re-initialize keyboards by entering
the monitor number and then
pressing the MON key.
DIP SWITCH 7:
ON = SOFTWARE RESET
OFF = NORMAL SYSTEM
OPERATION
6. Download your previous system
settings (revise settings as
Figure 54. CM6800 DIP Switch 7
necessary) from the CM6800-MGR.
Pelco Manual C1515M-A (11/01)
77
Download from Www.Somanuals.com. All Manuals Search And Download.
SOLUTIONS TO COMMON PROBLEMS
Refer to Table K for a list of common problems and their solutions.
Table K. Solutions To Common Problems
Problem
Remedy
CM6800 does not have power.
Make sure the power cord is plugged in.
You can see some cameras and not
others from your location.
Confirm that the camera is properly connected and has power.
The keyboard and monitor may have been denied access to the cameras.
The CM6800 does not respond to
keyboard commands.
Confirm that the monitor the keyboard is addressing is the same as the monitor in
front of you.
Access to that monitor may be restricted from that keyboard. Select another
monitor.
Pressing the PGM key displays a P on
the keyboard LED, but the Password
menu does not appear on the monitor.
(KBD100/200/300 Keyboards only)
Confirm that the keyboard transformer is plugged in and all electrical connections
are in order.
Confirm that the monitor the keyboard is addressing is the same as the monitor in
front of you.
Keyboards do not function after
installation and initial power-up.
Confirm that all wiring is correct and that keyboards have power and are connected.
Confirm that each keyboard has been set for a unique address.
Previous system control has been lost.
SOLUTION 1
Initialize the keyboard:
1. Enter the monitor number.
2. Press the MON key.
SOLUTION 2
1. Unplug the data cable from the rear of the keyboard.
2. Plug the data cable back into the rear of the keyboard.
3. Wait five seconds.
4. Re-initialize the keyboard.
SOLUTION 3
1. Power down the CM6800.
2. Power up the system.
3. Wait five seconds.
4. Re-initialize keyboards.
SOLUTION 4
Perform a software reset (refer to Software Reset in this section).
CAUTION: Resetting the software restores the system to default settings. All
user programming is lost. Uploading system settings to the CM6800-MGR
before the software reset allows you to restore system settings after the software
reset.
SOLUTION 5
Call Pelco’s 24-hour technical support at 1-800-289-9100 or 1-559-292-1981.
The unit malfunctions and you cannot
restore it to satisfactory operation.
Perform a software reset (refer to Software Reset in this section).
CAUTION: Resetting the software restores the system to default settings. All
user programming is lost. Uploading system settings to the CM6800-MGR
before the software reset allows you to restore system settings after the software
reset.
78
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
KBD960/KBR960 ICON/BUTTON LEGEND
LOG
OFF
JOYSTICK
ADJUST
MUX
LOG
OFF
JSTK
ADV
AUX 4, RELAY 4
AUX 5, RELAY 5
AUX 6, RELAY 6
AUX 7, RELAY 7
AUX 8, RELAY 8
4
5
6
7
8
QUAD
LOG OFF
YES
ADVANCE
MENUS
MUX
NINE
YES
NO
LOG OFF
NO
SERIAL PORT
TEST
MUX
SIXTEEN
SETUP/DEFINE
PIN
KEYBOARD
DOWNLOAD
MUX
LIVE
PIN
SAVE
SELECTION
KEYBOARD
UPLOAD
MUX
CAMERA CONTROL
RESET
ALARM
TEST GRAPHIC
PAGE 0
SEQUENCE
MENU
DEL
G0
G1
G2
T0
DELETE
SEQ
MORE
MENU
RESET
ALL ALARMS
CAMERA
PRESET
TEST GRAPHIC
PAGE 1
PRST
TEST GRAPHIC
PAGE 2
MUTE
EXIT
PATTERN
ZONE
CAMERA
SELECTION
TEST TEXT
PAGE 0
ALARM
MONITOR
DEFINE
MENU
GPI
GPI
MTRY
MAC
DEF
PARITY
SELECTION
MENU
SCROLL UP
SCROLL FIELD UP
RELAY
MOMENTARY
DIP SWITCH
TEST
PROGRAM
MENU
PGM
SCROLL DOWN
SCROLL FIELD DOWN
MACRO
SELECT
DISPLAY
BRIGHTNESS
DEFINE
NUMBER
DEF
LCD
NUM
PLAY FWD
DEVICE
PAUSE
PROGRAMMING
MENU
COM1
COM2
COM3
MENU
COM PORT 1
SCROLL RIGHT
PLAY BWD
SCROLL LEFT
COM PORT 2
STOP
SCROLL OPTION
UP
MUX
MENU
COM PORT 3
MUX
SCROLL OPTION
DOWN
MUX
AUX 1, RELAY 1
AUX 2, RELAY 2
AUX 3, RELAY 3
1
2
3
TAPE
KEYBOARD
SELECT
MUX
ZOOM
KEYBOARD
KEY TEST
MUX
PIC IN PIC
IN/OUT
FUNCTION
CONTROLS
FORWARD
RUN
BACKWARD
MACRO
RECALL/ALTERNATE
PRESET/LOCK
OTHER
CONTROLS
CAMERA
MONITOR
TURBO
IRIS
CONTROLS
NEAR/FAR
OPEN/CLOSE
ESCAPE
00665
Figure 55. Icon/Button Legend
Pelco Manual C1515M-A (11/01)
79
Download from Www.Somanuals.com. All Manuals Search And Download.
GLOSSARY
Term
Definition
Access
The CM6800 allows you to restrict system control by (1)
limiting the monitors or cameras a keyboard can access,
or (2) limiting the cameras that can be viewed on a
monitor.
Alarm display format
Alarm group
The CM6800 Matrix Switcher provides four formats for
displaying alarmed cameras on system monitors: Block
Build, Chronological Pair, Reverse Chronological Pair,
and Salvo Group.
To display on a monitor, an alarm must be assigned to
one or more alarm groups. The CM6800-48X8 Matrix
Switcher provides eight alarm groups (A through H). The
CM6800-32X6 Matrix Switcher provides six alarm groups
(A through F). Refer to Alarm Groups and Alarm Group
Display Options.
Alarm priority
A priority alarm appears on system monitors before a non-
priority alarm. Refer to the Priority description under
Internal and External Alarms.
ASCII
The binary, 7-bit, 128-character set implemented as the
standard in communications.
Auxiliary
Output relays can be used to control external devices
based on matrix switcher activities. External devices can
include VCRs, alarm devices, and triggers for audio
circuits.
Baud rate
Bit
In video, the greater the speed, the larger amount of
information passed. In digital systems, this capacity is
given in bits per second, or baud rates.
An abbreviation for “binary digit” - the smallest unit of
information a computer can use. A bit is either a 1 or a 0
(a high or low voltage state).
Byte
An abbreviation for “binary term” – bytes are strings of
bits, operated upon as a unit. A byte is equal to eight bits
(256 possibilities) and is large enough to hold one
character (like an “A” or the number “1”.)
Camera auxiliary
Coaxitron
Some cameras contain an auxiliary output relay, which
can be used to operate a device connected to the relay.
This is Pelco’s “up the coax” control technology. Control
signals are sent back up the coaxial cable that the video
signal travels down on.
COM port
This is a communication port input on the rear panel of the
matrix switcher.
Daisy-chain
This is a way of providing multiple connections in a series,
from one source. A daisy-chain configuration connects
multiple, linked devices from one output. When connecting
PTZ cameras to a matrix switcher, for example, one set of
cables connects the matrix switcher to each receiver, and
then each receiver is connected to the next receiver.
Dwell
This is the amount of time something happens in the
system, such as the amount of time a camera view
displays on a monitor, or an auxiliary is on.
80
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
Event timer
The matrix switcher can automatically initiate macros or
sequences based on time and date.
Extended Coaxitron
Frame scan
This is Pelco’s Coaxitron control technology that uses 32
bits to send a command.
A three-second camera scan followed by a three-second
pause.
Latching operation
Logical camera number
The auxiliary device remains on until a command is given
(by a system operator or system automation) to turn it off.
A user-selectable, variable number, which is associated
with an actual physical camera input on the rear panel of
the matrix switcher.
Macro
A sequence of commands or steps. Macros can be
operated automatically or manually. Automatic operation
can be based on specific times or dates (set through the
Event Timer).
Matrix switcher
This is also known as a cross-point switcher. The cross-
points are actually electronic switches that select any
video input onto any video output at any one time,
preserving the video impedance matching. One video
signal can simultaneously be selected on more than one
output. More than one video input can be selected on one
output, in a sequential switching between inputs (unless
the input is routed through a multiplexer, which allows
more than one input to be viewed on the output monitor at
any one time).
Momentary operation
Multiplexer (MUX)
The auxiliary output operation is activated briefly and then
turns off.
A multiplexer allows an operator to view more than one
video signal (usually either four, nine or sixteen signals) at
one time on a single monitor. A multiplexer can also send
these multiple images to the video recorder, switching
rapidly between image from each camera.
NTSC
The American color TV standard, used in North America,
Japan, and a few other countries. It specifies 525 lines/
screen, and 29-30 frames/sec.
Null modem cable
A null modem cable allows you to connect your PC to
another nearby PC or serial device by “crossing over”
(reversing) their respective pin contacts. (A null modem
cable is limited to 30 feet in length.)
PAL
The color TV standard (50Hz) used by European, Asian,
and some Latin American countries. It specifies 768
pixels/line, 576 lines/screen and 25 frames/sec.
Parity type
The parity bit is used to identify whether the bits being
moved arrived successfully. Parity bit checking can be
based on odd or even bits. No parity means that a parity
bit is not transmitted or checked.
Partitioning (access)
The CM6800 allows you to restrict system control by (1)
limiting the monitors or cameras a keyboard can access,
or (2) limiting the cameras that can be viewed on a
monitor.
Pelco Manual C1515M-A (11/01)
81
Download from Www.Somanuals.com. All Manuals Search And Download.
Pattern
A pattern is a user-defined, viewable camera path with a
definite beginning and end. The pattern can consist of any
standard pan and tilt or lens command. Once defined, the
pattern is easily activated by a system operator or through
an automated event. The pattern will run continuously until
it is deactivated. The number and time length of patterns
varies with different positioning systems.
Physical input
Preset
A number representing an actual BNC camera input on
the rear panel of the matrix switcher. This number cannot
be changed.
A preset allows operators to direct a PTZ (camera
positioning system) to move to a predetermined scene on
keyboard command or as a result of an alarm. In addition
to moving the camera, a descriptive title can appear on
the screen. The type of camera positioning system
determines the number of presets available.
Priority control
PTZ
This is the level of priority a system keyboard has to
control a PTZ camera positioning system and to access
CM6800 Matrix Switcher on-screen programming menus.
This is a camera positioning system with pan, tilt, and
zoom capabilities.
Random scan
This is a camera scan moving in a random pattern.
RJ-45 wall block
This is a wall block with eight terminals for connecting
RS-232, RS-422, and RS-485 communication lines. (This
is Pelco part number CON12J00820360Z.)
RS-232
RS-422
This is an Electronics Industry Association (EIA) interface
standard used for data communication; the normal
connection distance is 50 feet (15 m). Pelco uses this
standard for communication from a controller to a PC or
RS-232 network. The Pelco three-wire connection
provides one wire for transmit, one wire for receive, and
one wire for common.
This is an Electronics Industry Association (EIA) interface
standard. Pelco uses this standard for communication
from a controller to one or more camera receivers (on the
same line); the maximum recommended distance is 4,000
feet (1,219 m).
The four-wire connection provides two wires for transmit
and two wires for receive. Pelco receiver/driver
communication uses only the two transmit wires
(commands are sent from the controller to the receiver
only; the receiver does not “talk” back to the controller).
Pelco keyboard communication uses all four wires.
NOTE: The electrical communication scheme used by
Pelco is a direct-coupled method, not an AC-coupled
method. Therefore, if the ground potential of the wire at its
two end points is different (other than zero volts), an
additional wire is required as a ground.
82
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
RS-485
This is an Electronics Industry Association (EIA) interface
standard used for communication between multiple
transmitters and receivers; the maximum recommended
distance is 4,000 feet (1,219 m). The four-wire connection
provides two wires for transmit and two wires for receive.
NOTE: The electrical communication scheme used by
Pelco is a direct-coupled method, not an AC-coupled
method. Therefore, if the ground potential of the wire at its
two end points is different (other than zero volts), an
additional wire is required as a ground.
Scratchpad sequence
A scratchpad sequence can be run on an individual
system monitor, without entering the password-protected
CM6800 Matrix Switcher on-screen programming menus.
You can program scratchpad sequences from the
CM6800 Matrix Switcher on-screen programming menus
only, not from the CM6800-MGR software.
Sequence
Allows an operator to see a routine of 72 camera views on
any system monitor, over and over again. The sequence
can be operated automatically or manually. The order in
which the camera views appear and the time each view
remains can be programmed.
Standard Coaxitron
Star configuration
This is Pelco’s Coaxitron control technology that uses 15
bits to send a command.
This is a way of providing multiple direct connections from
one source. A star configuration uses a separate cable for
each direct connection, with all of the cables connected to
a central device. When connecting PTZ cameras to a
matrix switcher, for example, the central device can be a
code distribution unit, such as the CM9760-CDU-T. Each
camera has a direct connection to the CM9760-CDU-T,
which is the central device.
Synchronize
Since the CM6800 Matrix Switcher can be programmed
from either the CM6800-MGR software or the CM6800
Matrix Switcher on-screen programming menus, you could
potentially have different settings in the two programming
sources. Pelco recommends transmitting any
programming changes from the updated programming
source so that the next time you make changes from
either programming source, you will be modifying the
current system settings. Refer to Transmitting
Programming Settings.
System keyboard
This is a keyboard compatible with and connected to the
matrix switcher, allowing a system operator manual
control over the system.
System reset
This restores the system to the default settings, as
shipped from the factory.
Vertical drive/synchronization
This option sends a timing pulse from the matrix switcher
to a compatible camera. The camera aligns the vertical
synchronization with the timing pulse.
Zone
A zone is a user-defined, physical location to which (1) a
label is attached and (2) a camera is associated. When
the associated camera is panned through or remains
within this defined zone, the zone label appears on the
monitor. With some camera systems, a zone can be
blanked to prevent viewing while the camera is positioned
in the zone.
Pelco Manual C1515M-A (11/01)
83
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS
GENERAL
Memory Protection:
Lithium battery, two weeks of data protection
Keyboards:
Eighteen: Sixteen KBD100/200/300 Series keyboards and two
KBD960/KBR960 Series keyboards. (Switcher can provide
power for two KBD100/200/300 Series keyboards. Additional
keyboards will require a remote power supply.)
Receiver/Dome Control:
Alarm Inputs:
Coaxitron and RS-422
Eight individually programmable for N.O. or N.C. on rear
panel (plus an additional 128, via ALM2064, Alarm Interface
Units, providing a total of 136 possible)
Control Outputs on Rear Panel
AUX 1, 2:
Two relays (SPDT), rated at 0.5 amp @ 125V, 1 amp @
30 VDC, 60 milliohms contact resistance
F3:
One open collector (TTL); 15 VDC maximum, 25 mA maximum
Additional Outputs:
Two REL2064, Relay Interface Units, may be connected to
expand relay outputs to a maximum of 128
Communication Ports:
Eight data ports, two PTZ control ports, all programmable by
the user; two ports provide power for keyboards
ELECTRICAL
Input Power:
Power Consumption:
120V or 230V, 50/60Hz
25W
SWITCHER CHARACTERISTICS
Video Inputs, Looping: 40 BNC, terminating or looping (individually selectable per
camera), .5 to 2.0 Vp-p composite video, video loss detection
Video Inputs, Terminating: Eight, BNC, terminating, .5 to 2.0 Vp-p composite video, video
loss detection
Video Outputs:
Switching Type:
Switching Method:
Switching Time:
VIDEO
Six or eight outputs, BNC
Cross-point video matrix, NTSC and PAL compatible
Vertical interval switching
Less than 16 milliseconds (typical)
Bandwidth:
15 MHz
Frequency Response:
Signal-to-Noise Ratio:
Flat to 8 MHz, ±1dB to 13 MHz
-50 dB (peak-to-peak vs. RMS noise)
Adjacent Channel Crosstalk: -55 dB typical at 3.58 MHz
Differential Gain:
Differential Phase:
Gain:
0.03% typical
0.24° typical
Unity (±1dB)
Zero volts
DC Output:
84
Pelco Manual C1515M-A (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
CHARACTER GENERATION
Character Type:
White with black outline; adjustable brightness
Camera Identification:
Two lines, twenty-character title, plus camera number,
monitor number, date (four formats) and time (24-hour or AM/
PM formats)
Programmable:
On-screen, menu-driven
128 ASCII characters
Character Set:
ENVIRONMENTAL
Ambient Operating
Temperature:
Humidity:
20° to 120°F (-7° to 49°C)
10-90% non-condensing
MECHANICAL
Dimensions:
17.40 (W) x 5.25 (H) x 12.25 (D) inches (without rack ears)
(44.20 x 13.34 x 31.12 cm)
Mounting:
Factory-configured for EIA rack mount (3 RU); rack ears can be
removed for versatile wall mount or freestanding applications
Unit Weight:
12.7 lb (5.76 kg)
(Design and product specifications subject to change without notice.)
Pelco Manual C1515M-A (11/01)
85
Download from Www.Somanuals.com. All Manuals Search And Download.
REGULATORY NOTICES
This equipment has been tested and found to comply with the limits of a Class B digital
device, pursuant to part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However there is no guarantee that the interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try and correct the interference by one or more of the following measures:
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the re-
ceiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or
workmanship for a period of one year after the date of shipment.
If
a
warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following
information:
1. Model and serial number
Exceptions to this warranty are as noted below:
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
•
•
•
Five years on FT/FR8000 Series fiber optic products.
Three years on Genex® Series products (multiplexers, server, and keyboard).
If there is a dispute regarding the warranty of a product which does not fall under the
warranty conditions stated above, please include a written explanation with the product
when returned.
Three years on Camclosure® and fixed camera models, except the CC3701H-2,
CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models,
which have a five-year warranty.
Method of return shipment shall be the same or equal to the method by which the item was
received by Pelco.
•
•
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series
fixed dome products.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at
(800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned
for credit, and RA number if returned for repair).
•
Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, including when used in
continuous motion applications.
•
•
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing
charge.
Eighteen months on DX Series digital video recorders, NVR300 Series network video
recorders, and Endura™ Series distributed network-based video products.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA
number and freight should be prepaid. Ship to the appropriate address below.
•
•
One year (except video heads) on video cassette recorders (VCRs). Video heads will be
covered for a period of six months.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Six months on all pan and tilts, scanners or preset lenses used in continuous motion
applications (that is, preset scan, tour and auto scan modes).
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco
shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,
California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident
are not covered under this warranty.
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are
instructed to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from
the specific use or application made of the Products. Pelco’s liability for any claim, whether
based on breach of contract, negligence, infringement of any rights of any party or product
liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for
such Products. In no event will Pelco be liable for any special, incidental or consequential
damages (including loss of use, loss of profit and claims of third parties) however caused,
whether by the negligence of Pelco or otherwise.
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors
473 Eccles Avenue
The above warranty provides the Dealer with specific legal rights. The Dealer may also have
additional rights, which are subject to variation from state to state.
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
REVISION HISTORY
Manual #
C1515M
Date
5/01
8/01
11/01
Comments
Original version.
Updated certifications.
C1515M-A
Revised manual to describe updated functionality in the software.
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco.
Windows is a registered trademark of Microsoft Corporation.
Endura and ExSite are trademarks of Pelco.
© Copyright 2001, Pelco.
All rights reserved.
86
Pelco Manual C1515M-A (11/01)