INSTALLATION/OPERATION MANUAL
BREAKOUT PANELS FOR
VA6000 SERIES SWITCHER AND
CM8500 MATRIX SYSTEM
1.0 WARNINGS
Priortoinstallationanduseofthisproduct,thefollowing
WARNINGS should be observed.
1. Installation and servicing should only be done by
Qualified Service Personnel and conform to all
Local codes.
2. Unless the unit is specifically marked as a NEMA
Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is
designed for indoor use only and it must not be
installed where exposed to rain and moisture.
3. OnlyusereplacementpartsrecommendedbyPelco.
This product may bear the following marks:
This symbol indicates that dangerous voltage
constituting a risk of electric shock is present
within this unit.
This symbol indicates that there are important
operating and maintenance instructions in the
literature accompanying this unit.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
CAUTION:
TOREDUCETHERISKOFELECTRICAL
SHOCK, DO NOT REMOVE COVER. NO
USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
Please thoroughly familiarize yourself with the information in this manual
prior to installation and operation.
Pelco Manual C842M (9/96)
1
Download from Www.Somanuals.com. All Manuals Search And Download.
2.0 SCOPE
As was the case for the VA6000, all telescoped inputs
for breakout panels used with the CM8500 are con-
nected via the appropriate onboard header to existing
“D” type connectors on the rear of the CM8500 Matrix
bay via ribbon cables.
The information contained within this manual covers
the installation and operation of the Alarm Breakout
Panels for the VA6000 Series Switcher and the Alarm,
Wiretron and Relay Breakout Panels for the CM8500
Matrix system.
The 24 inch (.609 m) and 120 inch (3.048 m) length
ribbon cable assemblies for the 40-pin header type con-
nectors have the same configuration and can be used
with either the Wiretron Breakout Panel or the Alarm
Breakout Panel.
3.0 DESCRIPTION
VA6000
The Breakout Panels for the VA6000 Series provide a
convenient method for physically telescoping up to 20
alarm inputs down into the most appropriate of two
headers existing on the Alarm Breakout Panel board
for convenient connection to “D” type connectors on
the rear of the VA6000.
The ribbon cable used with the 50-pin header (also avail-
able in the same lengths) is used only with the Relay
Breakout Panel for the CM8500 system. Reference
Table II, Figure 12 as a guide for ordering information
related to CM8500 breakout panels while referencing
other appropriate figures in the manual.
A ribbon cable connects one of the two available header
types (15-pin or 25-pin header) to the appropriate “D”
type connector, depending on alarm input population,
on the rear of the VA6000. Basically, two classes of rib-
bon cable are available: one for use with 4 and 8 alarm
input models and another for 12 or 20 alarm input mod-
els. Cables are further differentiated by length–24 inch
(.609 m) or 120 inch (3.048 m) lengths are available.
NOTE: When working with a CM8500 Ma-
trix System, additional subassemblies may be
required (if not already installed) on the
CM8500 side of the installation in order to uti-
lize the Alarm, Wiretron and Relay connectors
on the rear of the CM8500 Matrix bay. These
are:
CM8506 Communication circuit card to al-
low the CM8500 to communicate
with Wiretron receiver/drivers.
Mounts to Buffer Card.
CM8532 32 alarm/32 relay circuit card kit
to allow for direct monitoring of
32 alarms and the use of 32 relay
outputs programmable in software.
Additionally, each breakout panel assembly is shipped
from the factory installed on a single mounting plate
with appropriate mounting hardware. You should auto-
matically receive the correct breakout panel, ribbon
cable, mounting plate and hardware if you use Table 1
in Figure 12 as a guide while referencing all other ap-
propriate figures provided in the manual.
CM8500
Consult your CM8500 manual (C501M) for in-
stallation requirements and any related infor-
mation, if needed.
The Breakout Panels for the CM8500 Matrix System
likewise provide a convenient method for physically
telescopingAlarm, Wiretron or Relay inputs down into
appropriate headers for eventual connection to “D” type
subconnectors on the rear of the CM8500 Matrix bay.
4.0 INSTALLATION
Breakout panels come from the factory installed on
single mounting plates; an appropriate ribbon cable is
included with the assembly. The Breakout panel and
plate can be mounted in any convenient, accessible lo-
cation. Once mounted, all user supplied wiring inputs
(alarm, wiretron or relay) can be connected and then
the supplied ribbon cable can be run between the header
on the breakout panel and the appropriate “D” type con-
nector on the equipment being used, whether VA6000
or CM8500.
Unlike the VA6000 which is populated with two head-
ers, each with different pin-outs on one breakout panel,
the CM8500 utilizes three different breakout panels
populated with only one header, with header pin-out
configurations for the type of breakout panel being used:
Alarm, Wiretron or Relay. For the CM8500, Breakout
panels for Alarm and Wiretron inputs utilize, in each
case, a single 40-pin header, while Relay Breakout pan-
els incorporate a single 50-pin header.
Once the panels are physically mounted and all wires
and cables are run, the product is ready for use.
2
Pelco Manual C842M (9/96)
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 1. Alarm Breakout Panel Assembly Information–VA6000 Series
Pelco Manual C842M (9/96)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
The table below lists the pin-out relationship between the alarm panel header, J2, and the 15-pin connec-
tor on the rear of the VA6000 switcher for 8 input alarms. The pattern serves equally well for VA models
with 4 input alarms: the first 4 Pin Numbers correspond to like numbered ALM numbers, with pins 5-10
unused and pins 11-15 serving the same functions as in the 8 input VA6000 Switcher model.
J2 Header Pin-out on Alarm Breakout
for VA6000
Alarm Pin-outs 1-8/VA6000
Rear Panel Connector
15-Pin Female Conn. on Switcher
Pin Numbers
Pin Numbers
ALM #
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
3
5
7
9
11
13
15
not used
not used
9
2 (not used)
4 (not used)
6
8
10
12
14
10
11
12
13
14
15
K1 - NO
K1 -COM
K1 - NC
Ext.Trig.
Comm
Figure 2. Installation Configuration and Pin Mapping for 4/8 Alarm Inputs-VA6000 Alarm Breakout Panel
4
Pelco Manual C842M (9/96)
Download from Www.Somanuals.com. All Manuals Search And Download.
The table below lists the pin-out relationship between the alarm panel header, J1, and the 25-pin con-
nector on the rear of the VA6000 switcher for 20 input alarms. The pattern serves equally well for VA
models with 12 input alarms: the first 12 Pin Numbers correspond to like numbered ALM numbers
with pins 13-20 unused and pins 21-25 serving the same functions as in the 20 input VA6000 Switcher
models.
J1 Header Pin-out on Alarm Breakout
for CM8500
Alarm Pin-outs 1-16/CM8500 Rear Panel-P4
ALM #
25-Pin Female Conn. on Switcher
Pin Number
Pin Number
1
1
1
2
2
3
3
3
5
4
4
7
5
5
9
6
7
8
9
6
7
8
9
11
13
15
17
19
21
23
25
2
10
11
12
13
14
15
16
17
18
19
20
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
4
6
8
10
12
14
16
18
20
22
24
K1 - NO
K1 -COM
K1 - NC
Ext.Trig.
Comm
Figure 3. Installation Configuration and Pin Mapping for 12/20 Alarm Inputs-VA6000 Alarm Breakout Panel
Pelco Manual C842M (9/96)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 4. Alarm Breakout Panel Assembly Information–CM8500 Series
6
Pelco Manual C842M (9/96)
Download from Www.Somanuals.com. All Manuals Search And Download.
The table below lists the pin-out relationship between the alarm panel header, J1, and P4 on the CM8500
for the first 16 alarms. The pattern serves equally well for alarms 17-32: P4 becomes P3 and the listed
alarms go from 17-32 instead of 1-16.
J1 Header Pin-out on Alarm Breakout
for CM8500
Alarm Pin-outs 1-16/CM8500 Rear Panel-P4
ALM #
Pin Number
Com
Pin Number
Alarm
1
1
...
1
...
2
20
...
2
3
2
...
3
21
...
4
5
3
...
4
22
...
6
7
4
...
5
23
...
8
9
5
...
6
...
7
...
8
...
9
...
10
...
11
...
12
...
13
...
14
...
15
...
16
24
...
25
...
26
...
27
...
28
...
29
...
30
...
31
...
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
6
7
8
9
10
11
12
13
14
15
16
32
...
33
...
34
...
...
35
32
Figure 5. Installation Configuration and Pin Mapping for the CM8500 Alarm Breakout Panel
Pelco Manual C842M (9/96)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 6. Wiretron Breakout Panel Assembly Information–CM8500 Series
8
Pelco Manual C842M (9/96)
Download from Www.Somanuals.com. All Manuals Search And Download.
The table below lists the pin-out relationship between the wiretron panel header, J1, and P5 on the
CM8500 for the first 16 wire control positions. The pin mappings serve equally well for wire controls
17-32: P5 becomes P6 and the listed WIR numbers go from 17-32 instead of 1-16.
J1 Header Pin-out on Wiretron Breakout
Panel for CM8500
Wire Control Pin-outs 1-16/CM8500
Rear Panel-P5
WIR #
Pin Number
Pin Number
1
1
...
3
...
5
...
7
...
2
...
4
...
6
...
8
1
3
5
7
2
3
9
11
13
15
17
19
21
23
25
27
29
31
2
4
...
9
5
...
10
...
12
...
14
...
16
...
21
...
23
...
25
...
27
...
29
...
318
...
33
...
...
11
...
13
...
15
...
20
...
22
...
24
...
26
...
28
...
30
...
32
...
34
6
7
8
9
4
6
8
10
11
12
13
14
15
16
10
12
14
16
18
20
22
24
26
28
30
...
35
32
Figure 7. Installation Configuration and Pin Mapping for the CM8500 Wiretron Breakout Panel
Pelco Manual C842M (9/96)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 8. Wiretron Breakout Panel Assembly Information–CM8500 Series
10
Pelco Manual C842M (9/96)
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 9. Installation Configuration for the CM8500 Wiretron Breakout Panel
Figure 10. Rack Panel Mounting Plate Dimensions
Pelco Manual C842M (9/96)
11
Download from Www.Somanuals.com. All Manuals Search And Download.
The table below lists the pin-out relationship between the relay panel header, J1, and P1 on the CM8500
for the first 16 relay output positions. The pin mappings serve equally well for relay outputs 17-32: P1
becomes P2 and the listed RELAY numbers go from 17-32 instead of 1-16.
J1 Header Pin-out on Relay
Breakout Panel for CM8500
Pin Number
Relay 1-16 Pin-outs CM8500
Rear Panel-P1
RELAY #
Pin Number
NO
NC
COM
1
...
2
...
...
5
...
...
8
...
...
3
...
...
6
...
...
9
1
2
3
4
5
6
7
8
1
...
...
4
...
...
7
2
3
...
...
10
...
...
13.
...
...
16
...
...
19
...
...
22
...
...
25
...
...
28
...
...
31
...
...
34
...
...
37
...
...
40
...
...
43
...
...
46
...
...
...
11
...
...
14
...
...
17
...
...
20
...
...
23
...
...
26
...
...
29
...
...
32
...
...
35
...
...
38
...
...
41
...
...
44
...
...
47
9
...
...
12
...
...
15
...
...
18
...
...
21
...
...
24
...
...
27
...
...
30
...
...
33
...
...
36
...
...
39
...
...
42
...
...
45
...
...
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
4
5
6
7
8
9
10
11
12
13
14
15
16
...
...
48
48
Figure 11. Pin Mapping for the CM8500 Relay Breakout Panel
12
Pelco Manual C842M (9/96)
Download from Www.Somanuals.com. All Manuals Search And Download.
5.0 MODELS
CM8500-WPNL-2 Wiretron breakout panel for up
to 16 outputs/panel; 2-foot (.609
m) inter connecting ribbon cable
supplied.
VA6008-APNL-2
VA6000 alarm breakout panel
for up to 8 alarm inputs; 2-foot
(.609 m) interconnecting ribbon
cable supplied.
CM8500-WPNL-10 Same as CM8500-WPNL-2, ex-
cept 10-foot (3.048 m) intercon-
VA6008-APNL-10 Same as VA6008-APNL-2, ex-
cept 10-foot (3.048 m) intercon-
necting ribbon cable.
necting ribbon cable.
CM8500-RPNL-2 Relaybreakoutpanelforupto16
outputs/panel;2-foot(.609m)in-
terconnecting ribbon cable sup-
plied.
VA6020-APNL-2
VA6000 alarm breakout panel
for up to 20 alarm inputs; 2-foot
(.609 m) interconnecting ribbon
cable supplied.
CM8500-RPNL-10 Same as CM8500-RPNL-2, ex-
cept 10 foot (3.048 m) intercon-
VA6020-APNL-10 Same as VA6020-APNL-2 ex-
cept 10-foot (3.048 m) intercon-
necting ribbon cable.
6.0 OPTIONAL ACCESSORIES
necting ribbon cable.
RK-1PNL
Rack kit for mounting one
breakout panel (see Figure 10).
CM8500-APNL-2 Alarm breakout panel for up to
16 alarm inputs/panel; 2-foot
(.609 m) interconnecting ribbon
cable supplied.
RK-4PNL
Rack kit for mounting up to four
breakout panels (see Figure 10).
CM8500-APNL-10 Same as CM8500-APNL-2, ex-
cept 10-foot (3.048 m) intercon-
necting ribbon cable.
Table I. Alarm Breakout Panel Assembly Part Numbers for VA6000 Series Switchers
# Of Inputs
4 or 8 Alarm Inputs
VA6008-APNL-2
VA6008-APNL-10
12 or 20 Alarm Inputs
VA6020-APNL-2
VA6020-APNL-10
Cable Length
24 in (.609 m)
cable
120 in (3.048 m)
cable
Table II. Breakout Panel Assembly Part Numbers for CM8500 Matrix System
Input Type
Alarm Inputs
Wiretron Control Outputs
Relay Outputs
CM8500-RPNL-2
CM8500-RPNL-10
Cable Length
24 in (.609 m)
cable
CM8500-APNL-2
CM8500-WPNL-2
120 in (3.048 m)
cable
CM8500-APNL-10 CM8500-WPNL-10
Figure 12. Simplified Part Number Ordering Tables
Pelco Manual C842M (9/96)
13
Download from Www.Somanuals.com. All Manuals Search And Download.
7.0 WARRANTY AND RETURN INFORMATION
WARRANTY
RETURNS
Pelco will repair or replace, without charge, any merchandise proved
defectiveinmaterialorworkmanshipforaperiodofoneyearafterthedate
of shipment.
In order to expedite parts returned to the factory for repair or credit, please
call the factory at (800) 289-9100 or (559) 292-1981 to obtain an
authorization number (CA number if returned for credit, and RA number
if returned for repair).
Exceptions to this warranty are as noted below:
All merchandise returned for credit may be subject to a 20% restocking
and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the
assigned CA or RA number and freight should be prepaid. Ship to the
appropriate address below.
•
•
Five years on FT/FR8000 Series fiber optic products.
Three years on Genex® Series products (multiplexers, server, and
keyboard).
Three years on Camclosure® and fixed camera models, except the
CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2,
and MC3651H-2X camera models, which have a five-year warranty.
•
If you are located within the continental U.S., Alaska, Hawaii or Puerto
Rico, send goods to:
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto
Rico and are instructed to return goods to the USA, you may do one of the
following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
•
•
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and
DF5/DF8 Series fixed dome products.
Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, includ-
ing when used in continuous motion applications.
Two years on Esprit® and WW5700 Series window wiper (excluding
wiper blades).
•
•
•
Eighteen months on DX Series digital video recorders, NVR300
Series network video recorders, and Endura™ Series distributed
network-based video products.
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
•
•
One year (except video heads) on video cassette recorders (VCRs).
Video heads will be covered for a period of six months.
If the goods are to be sent by a FREIGHT FORWARDER, send the goods
to:
Six months on all pan and tilts, scanners or preset lenses used in
continuousmotionapplications(thatis,presetscan,tourandautoscan
modes).
Pelco c/o Expeditors
473 Eccles Avenue
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
Pelco will warrant all replacement parts and repairs for 90 days from the
date of Pelco shipment. All goods requiring warranty repair shall be sent
freight prepaid to Pelco, Clovis, California. Repairs made necessary by
reason of misuse, alteration, normal wear, or accident are not covered
under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or
loss resulting from the specific use or application made of the Products.
Pelco’s liability for any claim, whether based on breach of contract,
negligence, infringement of any rights of any party or product liability,
relating to the Products shall not exceed the price paid by the Dealer to
Pelco for such Products. In no event will Pelco be liable for any special,
incidental or consequential damages (including loss of use, loss of profit
and claims of third parties) however caused, whether by the negligence
of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The
Dealer may also have additional rights, which are subject to variation from
state to state.
Ifawarrantyrepairisrequired,theDealermustcontactPelcoat(800) 289-
9100 or (559) 292-1981 to obtain a Repair Authorization number (RA),
and provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice
number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall
under the warranty conditions stated above, please include a written
explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by
which the item was received by Pelco.
Pelco
3500 Pelco Way, Clovis, CA 93612-5699 (559)
292-1981 • (800) 289-9100
FAX (800) 289-9150 or (559) 292-3827
International customers call 1-559-292-1981 or
FAX 1-559-348-1120
(Product specifications subject to change
without notice.)
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and
Spectra are registered trademarks of Pelco.
Endura and ExSite are trademarks of Pelco.
C842M
© Copyright 1996, Pelco. All rights reserved.
14
Pelco Manual C842M (9/96)
Download from Www.Somanuals.com. All Manuals Search And Download.
|