1.0 GENERAL  
1.1 IMPORTANT SAFEGUARDS AND WARNINGS  
Prior to installation and use of this product, the following WARNINGS should be  
observed.  
1. Installation and servicing should only be done by Qualified Service Personnel  
and conform to all Local codes.  
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or  
6P enclosure, it is designed for indoor use only and it must not be installed  
where exposed to rain and moisture.  
3. Only use replacement parts recommended by Pelco.  
4. After replacement/repair of this unit’s electrical components, conduct a resis-  
tance measurement between line and exposed parts to verify the exposed  
parts have not been connected to line circuitry.  
5. The installation method and materials should be capable of supporting four  
times the weight of the enclosure, pan/tilt, camera and lens combination.  
The product and/or manual may bear the following marks:  
This symbol indicates that dangerous voltage constituting a  
risk of electric shock is present within this unit.  
This symbol indicates that there are important operating and  
maintenance instructions in the literature accompanying this  
unit.  
CAUTION:  
RISK OF  
ELECTRIC SHOCK.  
DO NOT OPEN.  
CAUTION:  
TO REDUCE THE RISK OF ELECTRICAL SHOCK,  
DO NOT REMOVE COVER. NO USER-  
SERVICEABLE PARTS INSIDE. REFER SERVICING  
TO QUALIFIED SERVICE PERSONNEL.  
Please thoroughly familiarize yourself with the information  
in this manual prior to installation and operation.  
PELCO Manual C428M-B (2/98)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.0 DESCRIPTION  
Pelco’s SS30/SS3000 series is a full-sphere, discreet surveillance enclosure de-  
signed to be suspended from a ceiling and to complement the interior decor of  
businesses, hotels, and offices.  
The smoked finished lower dome effectively camouflages a CTTV security/  
surveillance system without compromising the quality of the video picture. An op-  
tional mirrored lower dome (SS3002) is available.  
The SS3000 Series has been engineered for ease of installation, serviceability, and  
relocation. The lower dome quickly and easily detaches from the upper dome for  
convenient access to the camera and pan/tilt.  
2.1 MODELS  
SS30  
Full-sphere enclosure with black opaque lower dome with  
smoked viewing window and fixed camera mount  
SS3000  
SS3002  
Full-sphere enclosure supplied with a black opaque lower  
dome with smoked viewing window. Fixed camera mount not  
supplied. This dome is designed for use with an optional pan/  
tilt assembly (PT280 series).  
Same as SS3000 except supplied with mirrored lower dome  
with 2 f-stop light loss.  
2.2 OPTIONS  
PT280-24P  
Light duty indoor pan/tilt, 24 VAC  
PT280-24P/PP  
PT280-24SL  
PT280-24SL/PP  
MRWA  
Same as PT280-24P except has preset position (PP) option  
Light duty indoor pan/tilt with continuous 360° operation  
Same as PT280-24SL except has preset position (PP) option  
Wall mount adapter  
MRCA  
Ceiling mount adapter  
4
PELCO Manual C428M-B (2/98)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.0 INSTALLATION  
Save the shipping carton and plastic packing in case the unit has to be returned for  
credit or repair.  
3.1 CONDUCTOR AND CABLE REQUIREMENTS  
Before installing the pan and tilt, determine the conductor requirements and length  
of cable you will need to run based on the following:  
Conductor requirements for the pan and tilt are as listed below, plus coax cable:  
Pan/Tilt  
5+ grnd  
Lens  
4
Cam AC  
2
PT280-24P/PT280-24SL  
PT280-24P/PP  
9+ grnd  
8
8
2
2
PT280-24SL/PP  
10+ grnd  
(Camera power, lens functions and video are fed through the input connector  
on the base of the pan/tilt.)  
The following are the cable requirements for the PT280 series pan and tilts:  
5 Conductor  
110 ft (33.53m)  
180 ft (54.86m)  
290 ft (88.39m)  
6 Conductor*  
210 ft (64.01m)  
330 ft (100.58m)  
530 ft (161.54m)  
20 Awg  
18 Awg  
16 Awg  
* Using 2 wire common  
3.2 WIRING INSTRUCTIONS  
To install and test the pan/tilt you will need to assemble the connector parts pro-  
vided. Refer to Section 3.3 for connector assembly.  
The PT280 series pan/tilts are prewired for all control functions (pan/tilt, motorized  
zoom lens, 24 VAC camera power, and video.All connections are made at the input  
connector, eliminating the need for wiring harnesses made in the field. When using  
Coaxitron Control Systems, consider using the C1906, C1906/PP, C1925 or C1925/  
PP factory assembled pretested cables which are wired for inverted applications.  
Wire the control cable per the wiring diagram provided in the PT280 Series Pan/Tilt  
manual, C324M, for the specific pan/tilt you are using. (The PT280-24P basic pan/  
tilt wiring diagram is included in this manual for reference only.)  
NOTE: If you are not using the  
C1906, C1906/PP, C1925, or C1925/  
PPpretested cable you must reverse  
the left/right and up/down function  
pins as shown in Figure 1.  
PELCO Manual C428M-B (2/98)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cable distances should not exceed the distances specified in Section 3.1. The fol-  
lowing are some recommended common installation practices.  
1. Always use jacketed stranded multi-conductor interconnecting cable between  
the control and the pan/tilt, with additional conductors than needed for future  
servicing and/or additions.  
2. Always use color-coded conductors for ease of wiring and to identify functions  
at a later date.  
3. Keep a wiring diagram with the system for later use and reference.  
QTY  
SYMBOL  
DESCRIPTION  
PART NUMBER  
2
1
2
1
14  
4
C1, C2  
M1  
M2  
J2  
S1-S4  
CAPACITOR, 15 MFD, 100V  
PAN MOTOR  
TILT MOTOR  
CONNECTOR  
CONNECTOR PINS  
SWITCH  
CAPU0015.0/100N  
2508001  
PS78001  
CONMAB6100  
CON66102-7  
SWI1SM1  
1
1
1
INPUT CONNECTOR  
MATING CONNECTOR ASSY  
ACTUATOR  
CON206044-1  
CONA14S  
SWIJS138B  
1
LENS MATING CONNECTOR  
CONMAS6100  
Figure 1. PT280-24P Wiring Schematic  
6
PELCO Manual C428M-B (2/98)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.3 CONNECTOR ASSEMBLY  
Installation and/or testing will require you to assemble the connector parts pro-  
vided. Fabricate the interconnecting cable according to the following steps (refer-  
ence Figure 2).  
1. Slide part Aof the cable clamp (item 1) over the end of the cable (item 1, part  
C) with the threaded end of the cable clamp facing the connector (item 5).  
2. If the cable has a diameter less than 1/2 inch (1.3 cm), slide the rubber boot  
(item 2) over the end of the cable and pull through the cable clamp to so that  
the boot encases the cable and forms a good seal.  
3. Strip back the cable jacket approximately 1-1/4 inches (3.2 cm) and separate  
the individual conductors (item 3).  
4. The contact pins supplied with the mating connector are the “crimp” type which  
may also be soldered if you so desired (item 4).  
5. After crimping or soldering the contact pins to the conductors, push them into  
the proper holes in the connector until they snap in place.  
6. Slide part A of the cable clamp toward the connector and screw the parts  
together. Attach part B (item 1) onto part A and connect both parts with the  
screws provided.  
NOTE: Contacts cannot be removed  
from the connector without the use  
of the appropriateAMP extraction tool  
which is available from Pelco.  
7. Connect the cable assembly to the unit and seat the connector by twisting the  
locking collar until it snaps into position.  
5
1
threaded end of  
cable clamp  
A
B
C
STEP 1  
FLEXIBLE RUBBER BOOT  
5
1
A
B
STEP 2  
C
2
5 **  
3
1
4
A
B
STRIP 1/8"  
C
STEPS 3-7  
CRIMP  
INSULATION  
CRIMP  
WIRE  
OUTSIDE  
JACKET  
OF CABLE  
STRIP 1"  
4
1
5
2
1
1
**  
3
8
9
ITEM 5 DETAIL  
15  
4
6
10  
16  
23  
3
9
14  
22  
28  
10  
15  
21  
20  
25  
28  
7
33  
37  
14  
11  
29  
34  
26  
16  
15  
FRONT VIEW  
FRONT VIEW  
FRONT VIEW  
37-PIN CONNECTOR  
28-PIN CONNECTOR  
16-PIN CONNECTOR  
3
1
3
1
4
7
4
6
THE MOST COMMONLY USED  
CONNECTOR PIN-OUT CONFIG-  
URATIONS ARE SHOWN HERE.  
REFERENCE THE CONNECTOR  
DRAWING APPLICABLE TO  
YOUR SITUATION.  
11  
8
9
7
14  
12  
FRONT VIEW  
9-PIN CONNECTOR  
FRONT VIEW  
14-PIN CONNECTOR  
Figure 2. Connector Assembly  
PELCO Manual C428M-B (2/98)  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.4 MOUNTING  
The SS3000 enclosure is designed to be suspended from a suitable length of 1-1/2"  
pipe threaded at both ends. This pipe can be interfaced to either a Pelco MRWA  
wall adapter, MRCA ceiling adapter, or coupled to a longer length of pipe (see  
Figure 3).  
Figure 3. Mounting Configurations  
8
PELCO Manual C428M-B (2/98)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.4.1 Ceiling/Wall Mounting  
1. Select an appropriate length of 1-1/2" NPT pipe for the mount you have se-  
lected. Once the mount is installed, insert and tighten the pipe to approxi-  
mately 30 ft lb, then tighten the 8-32 screw in the pipe nut to lock the pipe  
threads. Slide the black 10"OD “Schneider” ring over the pipe and then slide  
the upper dome onto the pipe and lock it out of the way with a suitable retainer.  
NOTE: The “Schneider” ring referred  
to in these instructions is a 10-inch  
black aluminum ring designed to fit  
around the square portion of the up-  
per dome. Use of this ring helps to  
camouflage movement of the dome.  
2. Screw the mounting flange (item 4, Figure 5) onto the pipe and tighten to  
approximately 20 ft lb. Tighten the 8-32 screw in the pipe nut to lock the pipe  
threads (refer to Figure 4).  
NOTE: Disregard step 3 if using the  
PT280-24SL pan/tilt.  
3. Align the three-hole pattern in the pan spindle (PT280-24P) with the holes in  
the lower bracket (item 5, Figure 5) and attach with 1/4-20 x 5/8" hex head  
bolts and lock washers provided. Tighten firmly.  
NOTE: When installing a PT280-  
24SL pan/tilt with the slip ring option  
you will need to remove one (1) of the  
1/4-20 fasteners holding the mount-  
ing flange to the SL2800 bracket.  
Pivot the pan/tilt assembly to one side  
to allow the connector and cable to  
pass through. After the connection is  
made, pull the connector back up into  
the pipe and reattach the mounting  
flange.  
4. Assemble the lower bracket and pan/tilt to the mounting flange (item 4, Figure  
5) using 1/4" x 5/8" hex head bolts, flat washers, and hex nuts provided.  
5. Attach the upper (drive) bracket (item 3) to the bottom (spindle side) of the  
pan/tilt using four (4) 10-32 x 1/2" pan head screws and lock washers pro-  
vided. Refer to Figure 5 for proper orientation.  
6. Feed the main cable from the control or receiver through the center of the  
1-1/2" pipe and connect it to the cable of the pan/tilt. Pull the cable and con-  
nector back up into the pipe so that it does not get caught on the rotating parts.  
NOTE: When mounting a long cam-  
era/lens assembly (13" to 15") into a  
SS3000 enclosure, it must be  
mounted to the pan/tilt backwards so  
the lens is to the rear of the pan/tilt.  
This is to allow full downward tilt of  
the long lens. This must also be taken  
into consideration when wiring the  
unit, as the motions will be reversed.  
7. Install the camera/lens assembly onto the tilt table of the pan/tilt. Connect the  
proper cables (camera, lens function).  
8. Remove the retainers from the upper dome and lower it until it seats itself on  
the upper (drive) bracket.  
NOTE: The small hole in the upper  
dome (for safety chain attachment)  
should be positioned at the back (con-  
nector) end of the camera.  
Figure 4. Locking the Pipe Nut  
PELCO Manual C428M-B (2/98)  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
9. Turn the system on and rotate the pan/tilt. Check for cable interference. Tilt the  
camera up and down and check for clearance of all moving parts.  
CAUTION: The lower  
dome will shatter if  
dropped. Always operate  
with the safety chain at-  
tached. Do not rotate pan/  
tilt by hand. Rotate by con-  
troller only.  
10. After all tests have been done and the system is functioning properly, attach  
the safety chain to the upper dome with the fasteners provided. Install the  
lower dome, being careful to align the viewing window.  
11. Check for sufficient clearance between the lens and the lower dome.  
NOTE: The “Schneider” ring is not  
shown in this diagram. It is de-  
signed to fit over the square por-  
tion of the upper dome (item 1).  
Figure 5. SS3000 Exploded Assembly Diagram  
10  
PELCO Manual C428M-B (2/98)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.5 ADJUSTMENTS  
To adjust the pan/tilt limits, perform the following steps. Refer to Figure 6 for limit  
stop locations.  
CAUTION: Do not at-  
tempt to adjust limit stops  
when pan/tilt is in opera-  
tion. Damage to the equip-  
ment can result. Also, do  
not operate equipment  
without limit stops. Do not  
remove or reposition fixed  
limit stop on the PT280-  
24P pan/tilt. DAMAGE  
WILL OCCUR.  
1. Factory pan limits are set to 0-355° and tilt limits at ±45°. Pan to the right using  
the joystick control until the desired RIGHT pan limit is reached.  
2. Adjust the pan limit stop until the actuator clicks. Lock the limit into position.  
3. Pan to the desired left position, adjust the pan limit stop until the actuator  
clicks, and lock into position.  
4. Pan to the left and right to verify exact positioning and tighten both stops se-  
curely.  
5. Remove the left cover plate by removing the two screws for access to the tilt  
limit stops.  
6. Loosen the screws and move the DOWN limit stop to the furthest position.  
Using the joystick control, tilt the unit to the desired down position.  
7. Move the DOWN limit stop until the actuator clicks. Lock the limit into position.  
8. Adjust the UP limit stop in the same way.  
9. Tilt up and down to verify exact positioning and tighten both stops securely.  
Figure 6. PT280-24P Limit Locations  
PELCO Manual C428M-B (2/98)  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.0 MAINTENANCE  
Clean the acrylic lower dome as necessary to maintain a clear picture. Be careful  
not to scratch the surfaces of the dome.  
Exterior Surface - Clean the dome's exterior surface with a nonabrasive cleaning  
cloth and cleaning agent that is safe for acrylic plastic. Either liquid or spray cleaner/  
wax suitable for fine furniture is acceptable.  
Interior Surface (Except Chrome) - Clean the same as the exterior surface.  
Interior Surface (Chrome) - The inside surface of a chrome dome is easily scratched.  
Use the following precautions to maintain the dome's surface.  
a. Always handle the dome from the outside of its circular flange.  
b. Never touch the coated inside surface. The acid in your fingerprints will even-  
tually etch the coating if the fingerprints are not carefully removed according  
to the recommended cleaning procedure in item “e.”  
c.  
If dust or other contaminants accumulate on the dome's interior, remove the  
debris with compressed air. Compressed air cans are available from photo-  
graphic equipment or electronic supply dealers.  
d. If heavy residue accumulates and cannot be removed with air pressure, rinse  
with water and immediately dry with air pressure so that water spots will not  
remain. Avoid wiping the coated surface with direct hand pressure - it will eas-  
ily abrade unless extreme care is taken. Once scratched, the dome cannot be  
recoated.  
e. If internal wiping is necessary, avoid hand rubbing. Instead, make a wick as  
follows:  
Use a very soft paper towel. Roll a section into a tightly wound tube. Tear the  
tube in half, and wet the fuzzy end of the wick with a solution of isopropyl  
alcohol diluted with water. Hold the dome with its opening facing downward  
and wipe the interior of the dome with the wet end of the wick. Use a circular  
motion, starting from the outside and spiraling into the center. Use a new wick  
for each two passes over the dome.  
12  
PELCO Manual C428M-B (2/98)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5.0 MECHANICAL PARTS LIST  
Table A. SS3000 Exploded Assembly Diagram (Corresponds to Figure 5)  
Item No.  
Quantity  
Description  
Part Number  
1
2
1
1
Dome, upper  
SS300010000  
SS300010001*  
SS331100*  
Dome, lower, smoked (SS30, SS3000)  
Dome, lower, chrome (SS3002)  
Bracket, upper drive (SS3000/SS3002)  
Bracket, mounting (hanging weld assy)  
Bracket, lower (SS3000/SS3002)  
Pipe, mounting  
3
4
1
1
SS30004000COMP  
SS300031001WA  
PM200C4000COMP  
SS34002COMP  
5
1
6
1
7
16  
1
Not used  
8
Not used  
9
Velcro, black, 5/8" wide x inch (not shown)  
Chain, #16 single jack x 6" length  
Trim edge, black/chrome (not shown)  
Snap body for chain assembly (not shown)  
Ring, Schneider, 10" OD x 9.812" ID (not shown)  
TV10002  
10  
11  
12  
13  
SB2511000  
7
SS300010004  
SB2511001  
1
1
SS30004100COMP  
14  
78  
Velcro, black, 5/8" wide x inch (not shown)  
TV10003  
* Part number is for the dome only. To order a complete lower dome assembly, specify the part numbers SS30004003COMP  
(smoked) and SS334200COMP (chrome). These part numbers include items 2, 10, 12, and 14.  
Table B. Parts for SS30 Fixed Mount Dome Only (Not Shown in Figure 5)  
Item No.  
Quantity  
Description  
Part Number  
1
2
3
4
5
1
1
1
1
1
Tilt table, fixed, black  
Pedestal spacer, black  
Dome support bracket  
Fixed bracket, black  
Pedestal mount, fixed  
CM14004100BCOMP  
CM30004001COMP  
CM30024000COMP  
EM14004001BCOMP  
PM74000COMP  
PELCO Manual C428M-B (2/98)  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6.0 SPECIFICATIONS  
ELECTRICAL  
Input voltage:  
24 VAC required for pan/tilt  
Running  
Power  
Requirements  
Pan:  
Starting  
.31 amp (7.5 vA)  
.38 amp (9.2 vA)  
.47 amp (11.2 vA)  
.56 amp (13.5 vA)  
Tilt:  
Connectors  
Pan/Tilt:  
Lens:  
AMP CPC type (mate supplied)  
Hirschmann MAB6100  
BNC  
Video:  
Camera Power: Spade lugs  
Motors: Two-phase induction type, instantaneous reversing  
Limit Switches:  
5 amp, external adjustment  
See Section 3.1  
Conductor  
Requirements:  
MECHANICAL  
(for detailed specifications refer to PT280 series product manual, C324M.)  
Pan:  
Movement in horizontal plane:  
PT280-24P  
PT280-24SL  
0-355°  
0-360°  
Pan Speed:  
Tilt:  
12°/sec ±1° (no load condition)  
±90° movement in vertical plane  
Tilt Speed:  
Max. Load:  
Dome Drive:  
3°/sec ± .5° (no load condition)  
15 lb (6.81 kg) at 5" from tilt table surface to center of gravity  
Lower dome mounts into upper dome with Velcro fasteners;  
complete assembly is driven by pan/tilt  
Max. Camera  
and Lens Length: 16.0 inches (40.6 cm) including BNC connector  
14  
PELCO Manual C428M-B (2/98)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GENERAL  
Construction:  
Upper dome:  
Black, U.L. 94HB rated ABS plastic  
Lower dome:  
Acrylic hemisphere with distortion free viewing window with  
light attenuation factor of 1 f-stop (SS30/SS3000) or mirrored  
lower dome with 2 f-stop (SS3002). Rotates with pan and tilt,  
camera, and lens  
Environment:  
Unit Weight:  
Dimensions:  
Indoor; 32° to 120°F (0° to 48.89°C)  
6 lb (2.72 kg) approximate  
See Figure 7  
(Design and product specifications subject to change without notice.)  
Figure 7. SS30/SS3000 Dimension Drawing  
PELCO Manual C428M-B (2/98)  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7.0 WARRANTY AND RETURN INFORMATION  
WARRANTY  
Pelco will repair or replace, without charge, any merchandise proved defective in  
material or workmanship for a period of one year after the date of shipment. Excep-  
tions to this warranty are as noted below:  
Two years on all standard motorized and fixed focal length lenses.  
Two years on Legacy®, Intercept®, PV1000 Series, CM6700/CM8500/CM9500/  
CM9750/CM9760 Matrix, Spectra, DF5 Series and DF8 Fixed Dome products.  
Two years on WW5700 series window wiper (excluding wiper blades).  
Two years on cameras.  
Six months on all pan and tilts, scanners or preset lenses used in continuous  
motion applications (e.g., preset scan, tour and auto scan modes).  
Pelco will warranty all replacement parts and repairs for 90 days from the date of  
Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to  
Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration,  
normal wear, or accident are not covered under this warranty.  
Pelco assumes no risk and shall be subject to no liability for damages or loss result-  
ing from the specific use or application made of the Products. Pelco’s liability for any  
claim, whether based on breach of contract, negligence, infringement of any rights  
of any party or product liability, relating to the Products shall not exceed the price  
paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any  
special, incidental or consequential damages (including loss of use, loss of profit  
and claims of third parties) however caused, whether by the negligence of Pelco or  
otherwise.  
The above warranty provides the Dealer with specific legal rights. The Dealer may  
also have additional rights, which are subject to variation from state to state.  
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or  
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the  
following information:  
1. Model and serial number  
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number  
3. Details of the defect or problem  
If there is a dispute regarding the warranty of a product which does not fall under  
the warranty conditions stated above, please include a written explanation with the  
product when returned.  
Ship freight prepaid to:  
Pelco  
300 West Pontiac Way  
Clovis, CA 93612-5699  
Method of return shipment shall be the same or equal to the method by which the  
item was received by Pelco.  
RETURNS  
In order to expedite parts returned to the factory for repair or credit, please call the  
factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA  
number if returned for credit, and RAnumber if returned for repair). Goods returned  
for repair or credit should be clearly identified with the assigned CA/RAnumber and  
freight should be prepaid. All merchandise returned for credit may be subject to a  
20% restocking and refurbishing charge.  
®Pelco and the Pelco logo are registered  
trademarks of Pelco.  
Ship freight prepaid to:  
Pelco  
300 West Pontiac Way  
Clovis, CA 93612-5699  
©Copyright 1998, Pelco. All rights  
reserved.  
16  
PELCO Manual C428M-B (2/98)  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Paxar Printer Monarch 9805 User Manual
Perreaux Digital Camera 6200B User Manual
Philips Indoor Furnishings 22FDF7013 User Manual
Philips VCR VR286 User Manual
Philips VCR VRX222AT User Manual
Philips VCR VRZ344AT User Manual
Philips Work Light WHS User Manual
Phoenix Gold Speaker 4 5 6 2 Way Compact Indoor Outdoor Speakers User Manual
Pitco Frialator Ventilation Hood 60149517 User Manual
Planet Technology Network Card WL U357 User Manual