I N S T A L L A T I O N / O P E R A T I O N
IDE Series
Network Dome Camera
Sarix™ Technology
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
Generating a Self-Signed Certificate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Selecting SNMP Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Configuring SNMP V2c . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Day Night Manual Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Turning Off Window Blanking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Available Camera Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Bit Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Rate Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
GOP Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Creating a New User . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Deleting an Event Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
3
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
Analytic Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Creating a new Profile. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Deleting a Profile. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Configuring a Behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
C2963M-C (8/10)
4
Download from Www.Somanuals.com. All Manuals Search And Download.
List of Illustrations
10 Aligning the Lower Dome with Camera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
11 Locking the Dome . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
12 Positioning the Top Cover of the Lower Dome . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
13 Attaching the 2.5 mm Stereo Headphone Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
14 Cat5 Cable Pin Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
15 24 VAC Connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
16 Alarm and Relay Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
17 Relay Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
18 Supervised Alarm Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
19 Supervised Alarm Input Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
20 Unsupervised Alarm Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
21 Normally Closed and Normally Open Unsupervised Alarm Input Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
22 Alarm Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
23 Live Video Page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
24 SSL Configuration Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
25 SSH Settings Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
26 SNMP V2c Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
27 SNMP V3 Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
28 Orientation Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
29 Digital Processing Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
30 Auto Exposure Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
31 Manual Exposure Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
32 Auto Focus Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
33 Manual Focus Page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
34 Tone Map Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
35 Auto White Balance Page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
36 Manual White Balance Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
37 Window Blanking Page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
38 Select Video Preset Configuration Page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
39 Custom Video Stream Configuration Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
40 Audio Configuration Page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
41 General Settings Page for Users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
42 Users Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
43 New Event Source Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
44 New Event Handler Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
45 Analytic Configuration Page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
5
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
Important Notices
LEGAL NOTICE
SOME PELCO EQUIPMENT CONTAINS, AND THE SOFTWARE ENABLES, AUDIO/VISUAL AND RECORDING CAPABILITIES, THE IMPROPER USE OF
WHICH MAY SUBJECT YOU TO CIVIL AND CRIMINAL PENALTIES. APPLICABLE LAWS REGARDING THE USE OF SUCH CAPABILITIES VARY
BETWEEN JURISDICTIONS AND MAY REQUIRE, AMONG OTHER THINGS, EXPRESS WRITTEN CONSENT FROM RECORDED SUBJECTS. YOU
ARE SOLELY RESPONSIBLE FOR INSURING STRICT COMPLIANCE WITH SUCH LAWS AND FOR STRICT ADHERENCE TO ANY/ALL RIGHTS OF
PRIVACY AND PERSONALTY. USE OF THIS EQUIPMENT AND/OR SOFTWARE FOR ILLEGAL SURVEILLANCE OR MONITORING SHALL BE DEEMED
UNAUTHORIZED USE IN VIOLATION OF THE END USER SOFTWARE AGREEMENT AND RESULT IN THE IMMEDIATE TERMINATION OF YOUR
LICENSE RIGHTS THEREUNDER.
REGULATORY NOTICES
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
•
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
You may also find helpful the following booklet, prepared by the FCC: “How to Identify and Resolve Radio-TV Interference Problems.” This
booklet is available from the U.S. Government Printing Office, Washington D.C. 20402.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this
equipment under Federal Communications Commission’s rules.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
VIDEO QUALITY CAUTION
FRAME RATE NOTICE REGARDING USER-SELECTED OPTIONS
Pelco systems are capable of providing high quality video for both live viewing and playback. However, the systems can be used in lower quality
modes, which can degrade picture quality, to allow for a slower rate of data transfer and to reduce the amount of video data stored. The picture
quality can be degraded by either lowering the resolution, reducing the picture rate, or both. A picture degraded by having a reduced resolution
may result in an image that is less clear or even indiscernible. A picture degraded by reducing the picture rate has fewer frames per second,
which can result in images that appear to jump or move more quickly than normal during playback. Lower frame rates may result in a key event
not being recorded by the system.
Judgment as to the suitability of the products for users’ purposes is solely the users’ responsibility. Users shall determine the suitability of the
products for their own intended application, picture rate and picture quality. In the event users intend to use the video for evidentiary purposes in
a judicial proceeding or otherwise, users should consult with their attorney regarding any particular requirements for such use.
OPEN SOURCE SOFTWARE NOTICE
This product includes certain open source or other software originated from third parties that is subject to the GNU General Public License (GPL),
GNU Library/Lesser General Public License (LGPL) and different and/or additional copyright licenses, disclaimers, and notices.
The exact terms of GPL, LGPL, and some other licenses are provided to you with this product. Please refer to the exact terms of the GPL and LGPL
at http://www.fsf.org (Free Software Foundation) or http://www.opensource.org (Open Source Initiative) regarding your rights under said license.
You may obtain a complete corresponding machine-readable copy of the source code of such software under the GPL or LGPL by sending your
request to digitalsupport@pelco.com; the subject line should read Source Code Request. You will then receive an email with a link for you to
download the source code.
This offer is valid for a period of three (3) years from the date of the distribution of this product by Pelco.
C2963M-C (8/10)
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
The IDE Series is a fixed network dome camera with a built-in, Web-based viewer for live streaming to a standard Web browser (Microsoft®
Internet Explorer® or Mozilla® Firefox®). The camera features open architecture connectivity for third-party applications and is also
Endura Enabled™ and compatible with Digital Sentry® to record, manage, configure, and view multiple live streams.
The camera supports two compression formats and many resolutions. The two standard compression formats include H.264 and MJPEG. The
dual streams can be configured for a variety of resolutions, frame rates, and bit rates.
The IDE Series includes 1.3 and 2.1 megapixel (MPx) models available in two camera styles: color or day/night. The day/night model has an
mechanical IR cut filter that increases camera sensitivity in low-light situations. The camera uses a 1/3-inch imager and accommodates
CS-mount lenses.
The camera also includes built-in Power over Ethernet (PoE), which supplies power to the camera through the network. If PoE is not available, the
camera is prewired for 24 VAC.
BUILT-IN ANALYTICS
All IDE Series models are preloaded with user-configurable behaviors. The device is capable of running up to three behaviors at the same time;
however, the number of behaviors is limited to the available processing power of the device and the type of analytic being used.
Pelco analytics are configured and enabled using a standard Web browser. The behaviors are also compatible with Endura® or a third-party
system that supports the Pelco Analytics API. Refer to the specific product documentation for instructions on how to configure and enable Pelco
analytics.
Models are also available with ObjectVideo® (OV) Suites. OV Suites require an OV ready-compliant system with an OV Ready™ video
management system to configure and enable the OV Analytic Suites that are preloaded on the dome. Refer to the ObjectVideo documentation for
instructions on how to configure and enable OV analytics.
7
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
MODELS
IDE10DN-0
Sarix indoor fixed dome network camera, extended platform, 1.3 megapixel, day/night, no lens, smoked dome, with built-in
Pelco analytics
IDE10DN-1
Sarix indoor fixed dome network camera, extended platform, 1.3 megapixel, day/night, no lens, clear dome with built-in
Pelco analytics
IDE10DN8-1
Sarix indoor fixed dome network camera, extended platform, 1.3 megapixel, day/night, 2.8 ~ 8 mm varifocal megapixel
lens, clear dome, with built-in Pelco analytics
IDE10DN-OCP1† Sarix indoor fixed dome network camera, extended platform, 1.3 megapixel, day/night, no lens, clear dome, with built-in
OV Event Counting Plus Suite
IDE10DN-OS1†
Sarix indoor fixed dome network camera, extended platform, 1.3 megapixel, day/night, no lens, clear dome, with built-in
OV Security Suite
IDE10DN-OSP1† Sarix indoor fixed dome network camera, extended platform, 1.3 megapixel, day/night, no lens, clear dome, with built-in
OV Security Plus Suite
IDE20DN-0
IDE20DN-1
IDE20DN8-1
Sarix indoor fixed dome network camera, extended platform, 2.1 megapixel, day/night, no lens, smoked dome, with built-in
Pelco analytics
Sarix indoor fixed dome network camera, extended platform, 2.1 megapixel, day/night, no lens, clear dome, with built-in
Pelco analytics
Sarix indoor fixed dome network camera, extended platform, 2.1 megapixel, day/night, 2.8 ~ 8 mm varifocal megapixel
lens, clear dome, with built-in Pelco analytics
IDE20DN-OCP0† Sarix indoor fixed dome network camera, extended platform, 2.1 megapixel, day/night, no lens, smoked dome, with built-in
OV Event Counting Plus Suite
IDE20DN-OS0†
Sarix indoor fixed dome network camera, extended platform, 2.1 megapixel, day/night, no lens, smoked dome, with built-in
OV Security Suite
IDE20DN-OSP0† Sarix indoor fixed dome network camera, extended platform, 2.1 megapixel, day/night, no lens, smoked dome, with built-in
OV Security Plus Suite
IDE20DN-OCP1† Sarix indoor fixed dome network camera, extended platform, 2.1 megapixel, day/night, no lens, clear dome, with built-in
OV Event Counting Plus Suite
IDE20DN-OS1†
Sarix indoor fixed dome network camera, extended platform, 2.1 megapixel, day/night, no lens, clear dome, with built-in
OV Security Suite
IDE20DN-OSP1† Sarix indoor fixed dome network camera, extended platform, 2.1 megapixel, day/night, no lens, clear dome, with built-in
OV Security Plus Suite
*To configure and enable Pelco analytics, one of the following systems is required:
•
•
•
Internet Explorer® 8.0 (or later) or Firefox® 3.0 (or later)
Pelco interface with remote operation from an Endura 2.0 (or later) system.
Pelco Analytics API which is available for download at http://pdn.pelco.com.
†To configure and enable ObjectVideo Suites, an OV ready-compliant system with OV Ready video management system is required.
C2963M-C (8/10)
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Getting Started
Before installing your network dome, thoroughly familiarize yourself with the information in this section of the manual.
NOTES:
•
•
•
Pelco recommends connecting the dome to a network that uses a Dynamic Host Configuration Protocol (DHCP) server to address devices.
Do not use a network hub when configuring the network settings for the dome.
To ensure secure access to the network dome, place the dome behind a firewall when it is connected to a network.
PARTS LIST
Remove all of the contents from the shipping box.
Qty Description
1
1
1
1
1
1
1
1
3
Back box with camera module
Surface mount
Lower dome (includes trim ring and bubble)
Dome liner
4-pin connector
2-pin connector
Quick Start Guide
Resource disc
MAC address labels (extra)
Installation tools and the following parts are needed but not supplied:
Qty Description
1
1
1
Lens (use either a megapixel or standard auto iris lens, depending on the camera model)
Service cable (IX-SC)
Mounting hardware
9
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
ì
î
ï
Relay and Alarm Connections: One relay that can be used to control an external circuit, and one alarm for physical input into the system.
Accessory Port: For use with compatible Pelco accessories.
RJ-45 Network Port: Connects the dome to the IP network. Also supplies power to the dome through the network using PoE. If PoE is not
available, the dome is prewired for 24 VAC.
ñ
ó
24 VAC Power Connections: Supports 24 VAC as the power source if PoE is not used.
Reset Button: Reboots the camera or restores the camera’s factory default settings. This button is recessed. Using a small tool, such as a
paper clip, press and release the reset button once to reboot the camera. Press and hold the reset button for 10 seconds to restore the
camera to the factory default settings.
r
s
Micro SD Card Slot: Saves a snapshot image to a micro SD card based on alarm activity.
Power LED: Glows solid green to indicate that the dome has power and flashes green during the boot cycle. The LED can be disabled
through the user interface. If this LED glows red (solid or flashing), contact Pelco Product Support at 1-800-289-9100 (USA and Canada) or
+1-559-292-1981 (International) for assistance.
t
Lens Mount: Fits a standard CS-mount lens. Use a megapixel lens with the IDE Series megapixel cameras. A standard definition lens
installed on a megapixel camera will limit the resolution of the camera and create poor image quality.
u
~í
~â
Auto Iris Lens Connector: Controls the auto iris lens. Insert the 4-pin connector from the DC drive auto iris lens into this connector.
NTSC/PAL Button: Toggles the service connector between NTSC and PAL formats. The default setting is NTSC.
Service Port: Outputs analog video. Use this port at the installation site to set up the field of view and to focus the camera. When a service
cable is connected to the dome, video to the IP stream is disabled.
~ä
~ã
Auto Back Focus Button: Sets the auto back focus mechanism. Press the button once to center the auto back focus mechanism and to
fully open the iris. Press and hold the button for three seconds to start the auto back focus mechanism and focus the camera.
Ethernet Activity/Link LED: Flashes green to indicate that data is being transmitted or received by the dome. Glows solid amber to
indicate that a live network connection is established and then turns off after one minute of operation.
PRODUCT LABEL
The product label lists the model number, date code, serial number, and Media Access Control (MAC) address. This information might be required
for setup. The product label is located on the side of the back box.
11
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
You can install the IDE Series network dome system using one of the following methods:
•
•
•
Installation in a suspended ceiling or a fixed ceiling/wall (refer to In-Ceiling Installation on page 12).
Installation using the ID-P pendant mount accessory (not supplied). For pendant mount installation instructions, refer to the documentation
supplied with the pendant mount.
IN-CEILING INSTALLATION
WARNING: Remove the foam insert from the back box before installing the system. The foam is inserted to secure the tilt ring; preventing
damage to the optical chassis during shipment.
1. Prepare the mounting surface:
a. Cut a 6-inch diameter hole in the ceiling.
b. Pull all wiring through the hole and terminate all wires (if not already terminated).
2. Install the lens on the back box:
NOTE: Megapixel lenses are designed and tested to deliver optimal image quality to megapixel cameras. A standard definition lens
installed on a megapixel camera will limit the resolution of the camera and create poor image quality.
a. Remove the cover from the lens mount.
b. Screw the lens onto the lens mount. Be careful to prevent dust from entering the space between the lens and the imager. If necessary,
use clean, compressed air to remove any foreign matter (refer to the instructions shipped with the lens). Make sure the lens does not
touch the camera imager when installed.
c. Connect the auto iris lens to the 4-pin connector located on the side of the camera. Pin connections for the iris drive connector are as
follows:
Pin DC (AID) Auto Iris Lens
3
4
1
2
3
4
Control coil negative (–)
Control coil positive (+)
Drive coil positive (+)
Drive coil negative (–)
1
2
Figure 2. Lens Pin Connections
3. Connect the wiring to the side of the back box:
a. Connect the network cable to the RJ-45 network port on the side of the camera. If the network has no PoE, connect a 24 VAC Class 2
b. Connect the necessary wiring for alarms and relays (refer to Wiring on page 19 more information.)
4. Install the back box by compressing the spring clips and pushing the back box through the hole. Tighten the machine screws completely to
secure the back box to the ceiling.
Figure 3. In-Ceiling Installation
C2963M-C (8/10)
12
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Apply power to the camera. The camera will complete a configuration sequence; the green LED flashes five times per second for
approximately two minutes and then turns solid after the sequence is complete.
NOTE: If the camera is not connected to a DHCP server and DHCP is enabled, the configuration sequence might take up to five minutes to
complete.
6. Position the camera:
a. View the camera image using the service jack or a Web browser.
b. Unlock the tab locks located on each side of the camera.
c. Manually rotate and tilt the camera module to position the camera. Do not over-rotate the module.
d. Lock the tab locks to secure the camera.
Figure 4. Positioning the Camera
ì
î
ï
ñ
Pan 368°
Tab lock
Rotate 355°
Tilt 180°
7. Focus the lens:
a. View the camera image using the service jack or a Web browser.
b. Press the auto back focus button once to center the focus mechanism. The button is located on the rim of the back box.
c. Manually adjust the zoom and focus of the lens to the desired field of view (refer to the instructions shipped with the lens).
d. Press and hold the back focus button for three seconds to start the auto back focus mechanism.
8. Install the dome liner and lower dome (refer to Dome Liner and Lower Dome Installation on page 16).
13
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
SURFACE INSTALLATION
WARNING: Remove the foam insert from the back box before installing the system. The foam is inserted to secure the tilt ring; preventing
damage to the optical chassis during shipment.
1. Prepare the mounting surface:
a. Using the surface mount ring as a template, drill holes for the mounting hardware. Prepare the ceiling as follows:
•
Standard ceiling: When mounting the dome camera to a standard ceiling, use either 6-32 toggle bolts (not supplied) or
#8 x 3.50-inch self-tapping screws (not supplied).
•
Concrete ceiling: When mounting the dome camera to a concrete system, use 8-32 studs and nuts (not supplied).
b. Drill a hole in the ceiling for wiring.
c. Pull all wiring through the hole and terminate all wires (if not already terminated).
d. Attach the surface mount ring to the mounting surface.
2. Install the lens on the back box:
NOTE: Megapixel lenses are designed and tested to deliver optimal image quality to megapixel cameras. A standard definition lens
installed on a megapixel camera will limit the resolution of the camera and create poor image quality.
a. Remove the cover from the lens mount.
b. Screw the lens onto the lens mount. Be careful to prevent dust from entering the space between the lens and the imager. If necessary,
use clean, compressed air to remove any foreign matter (refer to the instructions shipped with the lens). Make sure the lens does not
touch the camera imager when installed.
c. Connect the auto iris lens to the 4-pin connector located on the side of the camera. Pin connections for the iris drive connector are as
follows:
Pin DC (AID) Auto Iris Lens
3
4
1
2
3
4
Control coil negative (–)
Control coil positive (+)
Drive coil positive (+)
Drive coil negative (–)
1
2
Figure 5. Lens Pin Connections
3. Connect the wiring to the side of the back box:
a. Connect the network cable to the RJ-45 connector on the side of the camera. If the network has no PoE, connect a 24 VAC Class 2
b. Connect the necessary wiring for alarms and relays (refer to Wiring on page 19 for more information).
4. Install the back box in the surface mount ring by compressing the spring clips and pushing the back box through the hole. Tighten the
machine screws completely to secure the back box to the ceiling.
Figure 6. Surface Back Box Installation
C2963M-C (8/10)
14
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Apply power to the camera. The camera will complete a configuration sequence; the green LED flashes five times per second for
approximately two minutes and then turns solid after the sequence is complete.
NOTE: If the camera is not connected to a DHCP server and DHCP is enabled, the configuration sequence might take up to five minutes to
complete.
6. Position the camera:
a. View the camera image using the service jack or a Web browser.
b. Unlock the tab locks located on each side of the camera.
c. Manually rotate and tilt the camera module to position the camera. Do not over-rotate the module.
d. Lock the tab locks to secure the camera.
Figure 7. Positioning the Camera
ì
î
ï
ñ
Pan 368°
Tab lock
Rotate 355°
Tilt 160°
7. Focus the lens:
a. View the camera image using the service jack or a Web browser.
b. Press the auto back focus button once to center the focus mechanism. The button is located on the rim of the back box.
c. Manually adjust the zoom and focus of the lens to the desired field of view (refer to the instructions shipped with the lens).
d. Press and hold the back focus button for three seconds to start the auto back focus mechanism.
8. Install the dome liner and lower dome (refer to Dome Liner and Lower Dome Installation on page 16).
15
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
DOME LINER AND LOWER DOME INSTALLATION
1. Align the magnets on the dome liner with the magnets located on the camera module.
Figure 8. Installing the Dome Liner
2. Attach the leash of the lower dome to the back box.
Figure 9. Attaching the Leash
C2963M-C (8/10)
16
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Move the lower dome latches away from the bubble until you hear a click indicating the latches are open. Align the lower dome latches
WARNING: The lower dome latches must be in the open position. Never force the lower dome latches into the slots of the camera
module.
Figure 10. Aligning the Lower Dome with Camera
4. Move the lower dome latches toward the bubble until you hear a click.
Figure 11. Locking the Dome
5. Turn the top cover of the lower dome 90-degrees to conceal the camera latches, LED, and service jack.
Figure 12. Positioning the Top Cover of the Lower Dome
17
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICE CABLE
The camera includes a service port that outputs camera video. Use it at the installation site to set up the field of view and to focus the camera.
Pelco offers an optional service cable (IX-SC) that connects directly to the service port. The service cable has a male BNC output for most
standard viewers.
NOTE: The ICS-SC and CST150 are not compatible with this camera. If you have any questions about service cable compatibility, contact
Pelco Product Support at 1-800-289-9100 (USA and Canada) or +1-559-292-1981 (international).
To assemble a service cable for the camera, purchase the following items from an electronics supply store:
Qty Description
1
1
1
1
2.5 mm stereo plug (male)
CPM 88 miniature coaxial connector
RG174/U coaxial cable
1/8-inch shrink fit tubing, 1/2-inch long
To assemble the cable:
1. Attach the CPM 88 miniature coaxial connector to one end of the cable. Follow the directions supplied with the miniature coaxial connector.
2. Attach the 2.5 mm stereo plug to the other end of the coaxial cable (refer to the figure below):
a. Remove the support sleeve from the plug.
b. Slip the shrink fit tubing and support sleeve over the end of the cable.
c. Prepare the cable:
(1) Strip back the outer jacket 0.318 inch (8.06 mm) inch from the end of the cable.
(2) Pull back the coaxial braid shield.
(3) Strip back the insulating material 0.125 inch (3.18 mm) inch to expose the center conductor.
d. Solder the center connector of the cable to the shoulder pin of the plug.
e. Heat the shrink fit tubing around the center conductor and shoulder pin
f.
Pull the coaxial braid shield back through the crimp pin and solder it to the top of the crimp pin arm.
g. Crimp the end of the crimp pin around the cable.
h. Reassemble the support sleeve and the plug.
Figure 13. Attaching the 2.5 mm Stereo Headphone Plug
ì
î
ï
ñ
ó
r
s
t
2.5 mm Stereo Plug
Plug Shoulder Pin
Center Conductor
Support Sleeve
Shrink Fit Tubing
Coaxial Cable
Coaxial Braid Shield
Crimp Pin Arm
C2963M-C (8/10)
18
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING
CAT5 CABLE
Connect a Cat5 cable to the RJ-45 network port. The 8-pin connector includes video and PoE for the camera. PoE (IEEE 802.3af) injects power over
the same cabling that carries the network data, eliminating the need for a separate power supply. This simplifies the installation and operation of
the camera without affecting network performance.
NOTE: The camera will autosense and configure itself to use either a crossover cable or a straight cable.
1
8
8
1
2
3
4
5
6
8
7
1
8
7
6
5
4
3
2
1
Pin Function
1
2
3
4
5
6
7
8
TX+
TX–
RX+
PoE 1-2
PoE 1-2
RX–
PoE 3-4
PoE 3-4
Figure 14. Cat5 Cable Pin Descriptions
19
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
24 VAC CONNECTOR
Single Camera Wiring
If PoE is not available:
NOTE: Only use the 24 VAC wires if PoE is not available.
2. Attach the mating connector to the green connector on the side of the camera.
24V~
Figure 15. 24 VAC Connector
Multiple Camera Wiring
If you are operating the camera using 24 VAC and you are wiring more than one camera to the same transformer:
1. Connect one side of the transformer to pin 1 of the 2-position terminal block on all modules.
2. Connect the other side of the transformer to pin 2 of the terminal block on all modules.
NOTE: Failure to connect all modules identically might introduce video noise for some installations
ALARM AND RELAY CONNECTOR
2. Attach the mating connector to the green connector on the side of the camera.
.
Figure 16. Alarm and Relay Connector
C2963M-C (8/10)
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting a Relay Device
The camera has an output for activating an external device. It supports both momentary and continuous relay operation.
You can operate the relay interactively during an active connection, or it can operate automatically to coincide with certain events. Typical
applications include turning on lights or other electrical devices or activating a door, gate, or lock.
WARNING: Do not exceed the maximum rating of 12 VDC, 0.15 A.
Figure 17 shows how to wire the relay with its power source to the camera.
A1
R1
12 VDC, 150 mA MAX
Figure 17. Relay Wiring
Connecting Alarms
The camera provides an alarm input for external signaling devices, such as door contacts or motion detectors. Both normally open and normally
closed devices are supported.
Supervised Alarms
When an alarm is configured as a supervised alarm, the camera maintains a constant electrical current through the alarm circuit
(3.3 VDC, 1 ohm). If the alarm circuit length changes, due to an electrical short or a bypass, the voltage fluctuates from its normal state and
activates an alarm.
NOTE: Install the 1-kohm resistor as close to the switch as possible.
Figure 18 illustrates the alarm and no alarm conditions of a supervised alarm input. Whether the alarm is normally closed or normally open,
neither a cut nor a bypass can defeat these alarms.
NORMALLY CLOSED
NORMALLY OPEN
NO ALARM
GND
NO ALARM
GND
1 KΩ
1 KΩ
+V
+V
+V
+V
+V
+V
+V
+V
ALARM
GND
ALARM
GND
1 KΩ
1 KΩ
ALARM
GND
ALARM
GND
1 KΩ
1 KΩ
CUT
CUT
ALARM
GND
ALARM
GND
1 KΩ
1 KΩ
BYPASS
BYPASS
Figure 18. Supervised Alarm Conditions
Figure 19 illustrates the wiring configuration for supervised alarm inputs.
NORMALLY CLOSED
NORMALLY OPEN
A
1
A1
1 KΩ
1 KΩ
Figure 19. Supervised Alarm Input Wiring
21
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
Unsupervised Alarms
When an alarm is configured as an unsupervised alarm, the camera only activates an alarm when the normal alarm state (open or closed)
changes.
Figure 20 illustrates the alarm and no alarm conditions of an unsupervised alarm input.
NORMALLY CLOSED
NORMALLY OPEN
NO ALARM
GND
NO ALARM
GND
+V
+V
+V
+V
+V
+V
+V
+V
ALARM
GND
ALARM
GND
ALARM
GND
NO ALARM
GND
CUT
CUT
NO ALARM
GND
ALARM
GND
BYPASS
BYPASS
Figure 20. Unsupervised Alarm Conditions
Figure 21 illustrates the wiring configuration for unsupervised alarm inputs.
NORMALLY CLOSED
NORMALLY OPEN
A1
A1
Figure 21. Normally Closed and Normally Open Unsupervised Alarm Input Wiring
NOTE: A normally closed alarm input can be defeated with a bypass; a normally open input can be defeated with a cut.
Alarm Connections
Figure 22 shows how to wire the camera to an alarm.
ALARM A1
ALARM
Figure 22. Alarm Connections
C2963M-C (8/10)
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
DEVICE CONFIGURATION SEQUENCE
Once the device is installed and power is applied, the device will start a configuration sequence: the green LED flashes five times per second for
approximately two minutes and then glows solid green, indicating that the boot cycle is complete and the device is on line.
NOTE: If the device is not connected to a Dynamic Host Configuration Protocol (DHCP) server and DHCP is enabled, the configuration sequence
might take up to five minutes to complete.
Refer to the following sections for more information:
•
•
•
MINIMUM SYSTEM REQUIREMENTS
Network and processor bandwidth limitations might cause the video stream to pause or appear pixilated when additional Web-interface users
connect to the camera. Decrease the images per second (ips), resolution, compression, or bit rate settings of the Web interface video streams to
compensate for network/processor limitations.
The following minimum system requirements are needed to use a Web browser with the IP camera:
Processor: Intel® Core™ 2 Duo microprocessor, 2.6 GHz
Operating system: Microsoft® Windows® XP, Windows Vista®, or Mac® OS X 10.4
Memory: 2 GB RAM
Network interface card: 100 megabits (or greater)
Monitor: Minimum of 1024 x 768 resolution, 16- or 32-bit pixel color resolution
Web browser: Internet Explorer® 7.0 (or later) or Mozilla® Firefox® 3.0 (or later)
Media player: Pelco’s Media Player or QuickTime® 7.6.5 for Windows XP and Windows Vista, or QuickTime 7.6.4 for Mac OS X 10.4 (or later)
NOTE: This product is not compatible with QuickTime version 7.6.4 for Windows XP or Windows Vista. If either operating system is installed on
your computer, upgrade to QuickTime version 7.6.5.
Refer to the following sections for more information:
•
•
•
•
23
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSING THE IP CAMERA
The first time you access the camera, the live video page appears. By default, you are viewing the video as a public user and only have access to
the single stream live view.
If, for security purposes, users should not be allowed to view video without first logging on to the camera, change the permissions for public
users.
LOGGING ON TO THE CAMERA
1. Open the Web browser.
2. Type the camera’s IP address in the browser address bar.
NOTE: If you do not know the camera’s IP address, you can locate it using the Pelco Device Utility software.
3. Click the Login button in the navigation bar; a dialog box appears.
4. Type your user ID and password.
NOTE: If you are logging on to the camera as the administrator for the first time, the default User ID and Password are admin
(all lowercase). For security purposes, be sure to change the password after you log on for the first time.
5. Click Log In.
Refer to the following section for more information:
•
C2963M-C (8/10)
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Live Video Page
The live video page allows you to manage the way you view live video and capture images. You can also view live video from this page and
access menus on the navigation bar (based on user permissions).
Figure 23. Live Video Page
Refer to the following sections for more information:
•
•
•
•
25
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
LIVE VIDEO PAGE ICONS
Viewable icons are based on user permissions.
Show Device List: Displays a list of viewable cameras connected to the same virtual local area network (VLAN) as the camera to
which you are logged on.
Disable Viewer: Closes the live view window.
1 x 1 Mode: Displays a single video pane.
2 x 2 Mode: Displays 4 video panes in rows of two.
3 x 3 Mode: Displays 9 video panes in rows of three.
4 x 4 Mode: Displays 16 video panes in rows of four.
Select Stream: Selects the viewable video stream that is displayed in live view (primary or secondary) and selects unicast or multicast
settings.
Maximize Viewing Area: Scales the image to the full size of the browser. To resize the video pane to normal view, click the
Show Toolbar button in the upper-right corner of the window.
Show Toolbar: Returns the window to normal view. This option is only available after the window has been set to maximize the
viewing area.
Open Stream in New Window: Opens the video in a scalable, independent window. Opening the video in a separate window allows
you to view the video while other applications are running. This window can be minimized, maximized, or closed using the title bar
buttons of the active window. The window can also be resized by dragging the lower-right corner of the window.
Take a Snapshot: Captures the image displayed in the video pane and then saves it as a JPEG file.
C2963M-C (8/10)
26
Download from Www.Somanuals.com. All Manuals Search And Download.
SELECTING A STREAM
1. Click the Select Stream button.
2. Select one of the following stream options from the Select Stream page:
Primary Stream: To select this stream, click the button next to Primary Stream.
Secondary Stream: To select this stream, click the button next to Secondary Stream.
QuickView Stream: To select this stream, click the button next to QuickView Stream.
Event Stream: To select this stream, click the button next to Event Stream.
NOTE: If the secondary stream has not been configured, only Primary Stream, Event Stream, and QuickView Stream are available.
3. Select one of the following options to adjust the stream settings:
H.264 compression: Select the video transmission type from the Transmission drop-down menu. Available settings include Unicast and
Multicast. Select the media player from the Player drop-down menu. Available settings include Pelco Media Player or QuickTime.
JPEG compression: Select the image rate for the stream from the Image Rate drop-down menu. The available settings for the primary
and secondary streams depend on the Image Rate setting. The QuickView Stream has only two image rate settings: 2 ips and 1 ips.
4. Click the Select button to save the stream settings.
Refer to the following sections for more information:
•
•
•
•
•
•
•
PRIMARY STREAM AND SECONDARY STREAM
The Primary Stream and Secondary Stream are video streams that include compression, resolution, image rate, and bit rate settings. The streams
can be set up using a video preset setting, or they can be customized using the video configuration settings.
A video preset is a predefined video configuration that offers a good balance between video performance and bandwidth usage. For easy stream
configuration, use the Video Preset page located in the drop-down menu of the A/V Streams Tab.
To customize the Primary Stream or Secondary Stream use the Video Configuration page located in the drop-down menu of the A/V Streams Tab.
Configurable settings include the stream name, compression standard, resolution setting, image rate, and bit rate. The default names for the
streams are Primary Stream and Secondary Stream; however, if these stream names have been changed, the new names will replace the default
names (Primary Stream and Secondary Stream) on the Select Stream page.
QUICKVIEW STREAM
The QuickView Stream is a predefined JPEG video stream with VGA resolution. This low resolution, low frame rate stream is displayed when the
Imaging Tab settings are configured. This allows users to view changes to exposure, white balance, and tone map settings as they are configured
and before the settings are saved.
The QuickView Stream is also ideal for users who are connected to a network with processor bandwidth limitations that might cause a high
resolution, high frame rate video stream to pause or appear pixilated.
The aspect ratio of the QuickView Stream mirrors that of the Primary Stream. The only stream setting that is selectable is the framerate: 2 ips
or 1 ips.
27
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
EVENT STREAM
The Event Stream displays a list of alerts triggered by a running behavior (analytic). The alert includes a screen capture, the profile that was
triggered, and the zone where the alert was detected. For the Event Stream to work you must have a behavior profile running. To set up and run
behaviors, use the Analytic Configuration page located in the drop-down menu of the Events Tab.
UNICAST
A unicast transmission sends a separate video stream to each user that is requesting data. Although multiple users might request the same data
from the camera at the same time, duplicate video streams are transmitted to each user. Every unicast user that connects to the camera
consumes additional processing power, which limits the number of simultaneous users who can access the camera.
The camera supports a maximum of 20 simultaneous users.
MULTICAST
A multicast transmission sends data to multiple users at the same time using one transmission stream. Each multicast user that connects to the
camera consumes no additional processing power; therefore, multicast video streams can be sent to an unlimited number of simultaneous users.
C2963M-C (8/10)
28
Download from Www.Somanuals.com. All Manuals Search And Download.
TAKING A SNAPSHOT
1. Click the “Take a Snapshot” button.
2. The File Download dialog box opens, and the following message appears: “Do you want to open or save this file?”
3. Select one of the following options:
Open: Your computer’s photo editing program opens and displays the screen image. This function is available only when using
Microsoft® Internet Explorer® 7.0 (or later) or Mozilla® Firefox® 3.0 (or later).
Save: The image is saved as a JPEG file on your computer.
Cancel: The captured image is not saved or displayed and the dialog box closes.
NOTE: If you are using JPEG, the captured image will be the size of the largest MJPEG stream. If you are using H.264, the image is captured
using the QuickView Stream, which is approximately VGA resolution.
DISPLAYING VIDEO IN THE MULTISCREEN VIEW
Cameras connected to the same virtual local area network (VLAN) as the camera to which you are logged on can be displayed in a multiscreen
view. Use the 4-camera, 9-camera, or 16-camera view mode buttons to display video from multiple cameras simultaneously.
The camera you are logged on to is the default display for the upper-left video pane in the multiscreen view. The device name for this camera is
displayed in the gray area near the top of the page.
NOTE: Using Primary and Secondary streams in multiscreen view will limit the available processing power and create responsiveness issues for
the camera and PC. If you experience latency issues, set the camera streams to QuickView. Available processing power is determined by the
settings for compression standards, resolution, image rate, bit rate, and analytic configuration.
To select video to display in the individual multiscreen panes:
1. Click the desired View Mode display button.
2. Click the Show Device List button above the selected video pane. A list of cameras connected to the same VLAN as the camera to which
you are logged on appears in the video pane.
3. Click the name of the camera you want to view. The live video of the selected camera appears in the video pane.
4. Repeat steps 1 through 3 for the remaining video panes.
29
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
Settings Page
Depending on user permissions, the Settings page allows you to manage camera system settings, set up users, configure events, and control the
camera.
NOTE: The Settings menu might not be available if the user does not have permission to access this feature.
ACCESSING THE CAMERA MENUS
1. Log on to the camera.
2. Click the Settings link in the navigation bar located in the upper-right corner of the page; a list of menu tabs appears.
3. Place the mouse pointer over a tab to display a list of submenus.
Refer to the following sections for more information:
•
•
•
•
•
•
C2963M-C (8/10)
30
Download from Www.Somanuals.com. All Manuals Search And Download.
System Tab
Use the System tab to change the device name, configure the time settings, set up the text overlay for the live view, and display system
information. You can also use the System tab to generate a system log, reboot the camera, or to restore the camera's factory default settings.
General Settings
The General Settings page includes configurable fields for the device name, time server, and text overlay settings. The device name is the
user-friendly description of the camera displayed in the gray area near the top of screen.The time server is an external server that uses Network
Time Protocol (NTP) to synchronize the camera date and time settings. The text overlay settings allow you to customize the appearance of the
Web browser by displaying the device name and the date and time at the top or bottom of the live view.
You can also use the General Settings page to turn the camera’s power LED on or off and to configure the Simple Mail Transfer Protocol (SMTP)
server to send an email notification when an event handler is activated.
NOTE: Consult your network administrator for information on configuring email notification on your local network.
Information Settings
The System Information page fields are read-only and include the firmware version, hardware version, model number, and serial number of the
system. This information is typically required by Pelco Product Support for troubleshooting purposes.
CHANGING THE DEVICE NAME
1. Place your mouse pointer over the System tab.
2. Select General Settings from the drop-down menu.
3. Click the Device Name box and highlight the text.
4. Type a user-friendly name into the Device Name box (2 to 63 characters). A user-friendly name makes it easier to recognize the device on
the network. Examples of user-friendly names are Front Door, Lobby, or Parking Lot.
5. Click Save to save the new device name, or click Reset to restore to the previously saved device name.
CONFIGURING THE TIME SETTINGS
If the camera is connected to a Dynamic Host Configuration Protocol (DHCP) network that has time server properties configured, the camera will
synchronize automatically with the time server. If the DHCP network’s time server properties are not configured or the network does not have a
time server, you need to configure the DHCP settings manually.
1. Click the System tab.
2. Select General Settings from the drop-down menu.
3. Type the IP address of the time server in the Time Server field. The time server is an external server that uses Network Time Protocol (NTP)
to synchronize the camera date and time settings.
4. Select the Time Zone option. Select the continent and the region that are closest to the camera’s location from the Time Zone drop-down
menus.
NOTE: If your location observes a form of daylight saving time, the system will automatically change the time on the associated dates.
5. Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
31
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
CUSTOMIZING THE APPEARANCE OF THE TEXT OVERLAY
1. Click the System tab.
2. Select General Settings from the drop-down menu.
3. Set the Text Overlay settings:
Date/Time Overlay: Select Show to display the date and time in the live view overlay. The default setting is Hide.
Camera Name Overlay: Select Show to display the device name in the live view overlay. The default setting is Hide.
4. Select the display position for the overlay from the Position drop-down menu. Selections include Top Right, Top Center, Top Left, Bottom
Right, Bottom Center, and Bottom Left.
5. Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
GENERATING A SYSTEM LOG
1. Click the System tab.
2. Click the Generate System Log button to create a system log that can be used by Pelco Product Support for troubleshooting. Contact Pelco
Product Support at 1-800-289-9100 (USA and Canada) or +1-559-292-1981 (international).
REBOOTING THE CAMERA
1. Click the System tab.
2. Select General Settings from the drop-down menu.
3. Click the Reboot Camera button to restart the camera. Rebooting the camera does not change the configured camera settings.
RESTORING ALL CAMERA DEFAULTS
WARNING: This process cannot be undone; all user and custom settings will be lost.
1. Click the System tab.
2. Select General Settings from the drop-down menu.
3. Click the Restore All Camera Defaults button to restore the camera’s factory default settings.
NOTE: If the camera is not connected to a Dynamic Host Configuration Protocol (DHCP) network, the IP address settings for the camera will be
lost and the server will not recognize the camera. DHCP On is the default setting for the camera IP address.
Refer to the following section for more information:
•
C2963M-C (8/10)
32
Download from Www.Somanuals.com. All Manuals Search And Download.
Network Tab
Use the Network tab to change the camera’s general network settings, select the Secure Sockets Layer (SSL) settings, enable Secure Shell (SSH),
configure 802.1x port security, and select Simple Network Management Protocol (SNMP) settings.
General Network Settings
The General Network page includes configurable and read-only fields for network communication settings. Available settings include the
Hardware Address, Hostname, IP Address, Subnet Mask, Gateway, and DNS Servers.
You can also enable or disable the Dynamic Host Configuration Protocol (DHCP) server from the General Network page. DHCP automatically
assigns an IP address to the device if there is a DHCP server on the network. If DHCP is set to On, the IP address, subnet mask, gateway, and DNS
server settings are read-only text. If DHCP is set to Off, these settings must be manually changed. The default camera setting for DHCP is On.
SSL Settings
To ensure security on the Internet, all Web browsers provide several security levels that can be adjusted for sites that use SSL technology to
transmit data. SSL encrypts communications, making it difficult for unauthorized users to intercept and view user names and passwords.
SSL requires signed certificates to determine if the Web browser accessing the camera has the required authentication. The camera can
generate a certificate signing request (CSR) that can be sent to a certificate authority for a signature (for example, VeriSign®), or it can generate
a self-signed certificate using the Generate Self-Signed Certificate option.
SSH Settings
SSH is a user-enabled protocol that allows Pelco Product Support to log on to and service the camera for advanced troubleshooting purposes.
From this page, users with the appropriate permissions can enable or disable SSH access to the camera.
802.1x
802.1x is a port security that authenticates devices that want to establish a point-to-point access through a wired or wireless port using
Extensible Authentication Protocol (EAP). This port-based authentication method prevents unauthorized access to a Local Area Network (LAN)
through a physical port. For example, when a device is connected to a network port, the network switch will ask the device for authentication.
If the credential is accepted when the device sends a credential to the network switch, the network switch will open the port for normal use.
If authentication fails, the device is prevented from accessing information on the port.
SNMP
SNMP is an application layer protocol used to manage TCP/IP-based networks from a single workstation or several workstations. The camera
supports SNMP versions 2c and 3 and can be configured to send data using a trap.
Refer to the following sections for more information:
•
•
•
•
•
•
•
•
•
33
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
CHANGING THE HOSTNAME
1. Place your mouse pointer over the Network tab.
2. Select General from the drop-down menu.
3. Click in the Hostname box and highlight the text.
4. Type a user-friendly name into the Hostname box (1 to 21 characters) using any combination of alphanumeric characters. A user-friendly
name makes it easier to recognize the device on the network.
5. Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
TURNING ON DHCP
The default Dynamic Host Configuration Protocol (DHCP) setting for the camera is DHCP On. If the DHCP option is set to Off, complete the
following steps to reset it to On.
1. Place your mouse pointer over the Network tab.
2. Select General from the drop-down menu.
3. Select the On option for DHCP.
4. Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
NOTE: If the camera is not connected to a DHCP server but DHCP is set to On, the default IP address 192.168.0.20 on subnet mask 255.255.255.0
is automatically assigned to the camera. After the first camera is connected and assigned the default IP address, the system will automatically
look for other cameras on the auto IP address system and assign IP addresses in sequential order as required. For example, if three cameras are
connected to a network without a DHCP server, the first camera will be assigned address 192.168.0.20, the second camera will be assigned
address 192.168.0.21, and the third camera will be assigned address 192.168.0.22.
TURNING OFF DHCP
WARNING: Contact your network administrator to avoid any network conflicts before setting or changing the IP address of the device.
1. Place your mouse pointer over the Network tab.
2. Select General from the drop-down menu.
3. Select the Off option for the Dynamic Host Configuration Protocol (DHCP).
4. Change the following network settings as required:
IP Address: The address of the camera connected to the network.
Subnet Mask: The address that determines the IP network that the camera is connected to (relative to its address).
Gateway: The router that accesses other networks.
DNS Servers: The addresses of the dedicated servers that translate the names for Web sites and hostnames into numeric IP addresses.
5. Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
C2963M-C (8/10)
34
Download from Www.Somanuals.com. All Manuals Search And Download.
SELECTING THE SECURE SOCKETS LAYER MODE
Figure 24. SSL Configuration Page
1. Place your mouse pointer over the Network tab.
2. Select SSL from the drop-down menu.
3. Select one of the following modes:
Required: A signed Secure Sockets Layer (SSL) certificate must be installed, and a secure URL that begins with the protocol name “https:”
must be used to access the camera. Sensitive data is always encrypted during transmission. A URL that begins with the "http:" protocol
rather than the “https:” protocol will be redirected to the secure URL automatically.
Optional: A signed SSL certificate must be installed, but a secure URL that begins with the protocol name “https:” is optional when
accessing the camera. You can also access the camera using a standard URL with the “http:” protocol, but sensitive data is not encrypted
during transmission. To ensure that sensitive data is encrypted, you must use a secure URL with the “https:” protocol.
Disabled (default): Turns off access to the Web client through SSL. Sensitive data will not be encrypted during transmission.
NOTE: If the SSL mode is set to disabled, you cannot access the camera using a URL that begins with an “https:” protocol. Your Web browser
displays an error message if you do not type the camera URL correctly.
Refer to the following sections for more information:
•
•
35
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
GENERATING A CERTIFICATE REQUEST
1. Place your mouse pointer over the Network tab.
2. Select SSL from the drop-down menu.
3. Click the Install Certificate button located at the bottom of the SSL Configuration page. The Select Certificate Install Method option buttons
appear on the page.
4. Select Generate Certificate Request, and then click Next. The Certificate Request Form opens.
5. Fill in all of the fields, and then click Generate Request. The following progress message appears on the page: “Generating certificate
signing request, please wait.”
6. Send the CSR, which looks like an encrypted block of undecipherable text, to a third-party certificate authority of your choice for a
signature.
7. After you receive the signed certificate, click the Install Certificate button to upload the signed certificate to the device.
8. After the certificate is uploaded, select the desired mode.
9. Click Save.
NOTE: Depending on the third-party certificate authority that signed your certificate, you might need to renew your certificate after a specified
amount of time. Consult the certificate authority for more details.
GENERATING A SELF-SIGNED CERTIFICATE
1. Place your mouse pointer over the Network tab.
2. Select SSL from the drop-down menu.
3. Click the Install Certificate button located at the bottom of the SSL Configuration page. The Select Certificate Install Method option buttons
appear on the page.
4. Select the “Generate Self-signed Certificate” option, and then click Next. The “Self-signed Certificate Information Form” opens.
5. Fill in all of the fields, and then click Generate Request. The following progress message appears on the page: “Your changes are being
applied. This process might take up to 3 minutes.” After three minutes, the certificate is uploaded to the device.
6. After the certificate is uploaded, select the desired mode.
7. Click Save.
NOTE: Self-signed certificates are valid for one year. The certificate’s expiration date is listed in the Installed Certificate information section.
If the certificate has expired and you attempt to access the camera using a secure URL, the Web browser displays a message. Repeat this
procedure to generate and upload a new certificate.
C2963M-C (8/10)
36
Download from Www.Somanuals.com. All Manuals Search And Download.
ENABLING SECURE SHELL
Figure 25. SSH Settings Page
1. Place your mouse pointer over the Network tab.
2. Select SSH from the drop-down menu.
3. Select the Enabled check box.
NOTE: The username is always root and cannot be changed. The username and password are required when accessing the camera through a
third-party SSH client.
4. Click in the Password box and type a password (4 to 16 alphanumeric characters). Passwords are case-sensitive.
5. Click in the Re-type Password box and retype your password.
6. Click the Save button to save the password and enable SSH, or click the Reset button to clear all of the information you entered without
saving it.
CONFIGURING THE 802.1X PORT SECURITY SETTINGS
WARNING: To prevent network conflicts, contact your network administrator before configuring the 802.1x port security settings.
1. Place your mouse pointer over the Network tab.
2. Select 802.1x from the drop-down menu.
3. Select the On option for the 802.1x Port Security. The default setting for 802.1x is Off.
4. Select the Extensible Authentication Protocol (EAP) method from the Protocol drop-down menu. Supported EAP methods include EAP-MD5,
EAP-PEAP, EAP-TLS, and EAP-TTLS.
5. Type the information required for the selected 802.1x authentication method.
6. Connect the PC to a 802.1x secured switch with like authentication protocols.
7. Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
37
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
SELECTING SNMP SETTINGS
WARNING: The Simple Network Management Protocol (SNMP) settings are advanced controls. Consult your network administrator to
obtain the required information to configure SNMP settings.
1. Place your mouse pointer over the Network tab.
2. Select SNMP from the drop-down menu.
3. Select the SNMP Version: None, V2c, or V3. None disables the SNMP configuration and is the default setting.
NOTE: SNMP V2c and SNMP V3 configuration settings are independent of each other, but only one SNMP version can be active at a time.
CONFIGURING SNMP V2C
Figure 26. SNMP V2c Settings
1. Place your mouse pointer over the Network tab.
2. Select V2c as the SNMP Version.
3. Type the community name in the Community String box. The default name for the Community String is ”public.”
4. Configure the Trap Configuration settings.
Address: Type the hostname or IP address of the recipient of the trap message.
Community String: Type the name of the community that should receive the trap message.
5. Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
C2963M-C (8/10)
38
Download from Www.Somanuals.com. All Manuals Search And Download.
CONFIGURING SNMP V3
Figure 27. SNMP V3 Settings
1. Place your mouse pointer over the Network tab.
2. Select V3 as the SNMP Version.
3. Type the SNMP user name in the SNMP user field.
4. Select the encryption algorithm for authentication from the Authentication drop-down menu: None, MD5, or SHA. If you use authentication
method MD5 or SHA, type a password in the text box to the right of the selected Authentication encryption.
5. Select the privacy encryption algorithm setting from the Privacy drop-down menu: None, DES, or AES. If you use privacy method DES or
AES, type a password in the text box to the right of the selected Privacy encryption.
6. Configure the address for the Trap Configuration. The Address is the hostname or IP address of the recipient of the trap message.
7. Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
39
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
Imaging Tab
Use the Imaging tab to change the camera’s general image settings, adjust the camera exposure, program the focus mechanism, adjust the tone
map settings to increase scene detail, tune the white balance settings for scenes with fluctuating lighting conditions, or define window blanking
privacy areas.
General Imaging Settings
General imaging settings include adjustments for camera orientation and digital processing. The Orientation settings reconfigure the image
180 degrees horizontally and 180 degrees vertically. Use these settings when installing the camera in an inverted position. If the orientation is
not adjusted, the image will display upside down and mirrored.
Digital processing settings can be set to Auto or Manual to adjust the camera’s sharpness, saturation, and contrast. When set to Auto, the
camera continually delivers the best possible image by automatically adjusting the digital processing settings based on the scene. Auto is the
default setting. Manual digital processing is recommended only for indoor applications that have a single, unchanging primary light source.
Exposure Settings
Exposure is the amount of light detected by the camera sensor. A scene with correct exposure settings has adequate detail and contrast between
white and dark values. An image with too little or too much exposure eliminates detail in the scene. The camera features Auto and Manual
exposure settings. Auto exposure automatically sets the amount of light detected by the camera sensor based on settings for light control,
exposure compensation, and the day and night exposure times. Manual exposure sets the amount of light detected by the camera sensor based
on a user-defined setting. Manual exposure is recommended only for indoor applications that have a single, unchanging primary light source.
Auto is the default setting.
Focus Settings
Focus sets the back focus to the center focal point of the scene. The camera can be configured to back focus automatically or manually. Auto
focus automatically back focuses the camera on the subject in the center of the scene. Manual focus turns off the auto focus mechanism and
locks the camera at a user-specified position. The manual focus setting is recommended only for indoor applications that have a single,
unchanging primary light source. The Focus page also includes Full Range Auto-Focus, Quick Auto-Focus, and a Factory Defaults.
Tone Map Settings
Tone map balances the brightest and darkest sections of a scene to produce an image with more balanced lighting and more detail. This is
accomplished, in part, when the device maps the 10-bit input sensor data (0 to 1023 bits) into 8-bit output RGB values (0 to 255 bits).
White Balance Settings
White balance settings define how the camera processes video images to render true colors in a scene. White balance is especially effective in
scenes with changing lighting conditions or in scenes with more than one type of light source. For example, scenes that benefit from white
balance correction are outdoor scenes, indoor scenes that include a window or door that opens to the outdoors, or indoor scenes that include
both incandescent and fluorescent lighting.
C2963M-C (8/10)
40
Download from Www.Somanuals.com. All Manuals Search And Download.
Window Blanking Settings
Window blanking is used to conceal user-defined privacy areas. A blanked area appears on the screen as a solid gray window. The camera can
handle up to four blanked windows as long as the total blanked area does not exceed 50 percent of the field of view.
Refer to the following sections for more information:
•
•
•
•
•
•
•
•
•
•
•
•
•
CONFIGURING THE ORIENTATION OF THE SCENE
Figure 28. Orientation Page
1. Place your mouse pointer over the Imaging tab.
2. Select General from the drop-down menu.
3. Select one of the following options:
•
•
Click the “Flip left-to-right” box to rotate the camera image 180 degrees horizontally.
Click the “Flip top-to-bottom” box to rotate the camera image 180 degrees vertically.
41
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
CHANGING THE DIGITAL PROCESSING SETTINGS
Figure 29. Digital Processing Page
1. Place your mouse pointer over the Imaging tab.
2. Select General from the drop-down menu.
3. Select the mode: Manual or Auto. Auto is the default.
4. Move the slider to the left or right to change the following settings:
Sharpness Adjust/Sharpness: Controls the clarity of detail in a scene. Move the slider to the right to increase the sharpness; move the
slider to the left to decrease the sharpness. Increasing the sharpness also increases the image noise. The auto range of adjustment is –
100 to 100; the auto default setting is 0 (zero). The manual range of adjustment is 0 to 100; the manual default setting is 50.
Saturation Adjust/Saturation: Controls how intense or vivid the colors are in a scene. Move the slider to the right to increase the
saturation level; move the slider to the left to decrease the saturation level. The auto range of adjustment is –100 to 100; the auto default
setting is 0 (zero). The manual range of adjustment is 0 to 100; the manual default setting is 50.
Contrast Adjust/Contrast: Controls gradations between the darkest and lightest portions of the scene. Move the slider to the right to
increase the contrast; move the slider to the left to decrease the contrast. The auto range of adjustment is –100 to 100; the auto default
setting is 0 (zero). The manual range of adjustment is 0 to 100; the manual default setting is 50.
C2963M-C (8/10)
42
Download from Www.Somanuals.com. All Manuals Search And Download.
SELECTING AUTO EXPOSURE SETTINGS
Figure 30. Auto Exposure Page
1. Place your mouse pointer over the Imaging tab.
2. Select Exposure from the drop-down menu.
3. Select the Auto mode.
4. Select the Light Control method: Digital Exposure or Auto-Iris Exposure.
Digital Exposure: This setting automatically adjusts the sensor exposure time depending on the light level at the scene. For very bright
scenes, the exposure time is very short and, as the scene becomes less bright, the exposure time is increased until the maximum exposure
time is reached. Digital Exposure is the default setting and provides the best image quality for the majority of scenes.
Auto-Iris Exposure: This setting automatically adjusts the lens iris depending on the light level at the scene. For this setting, the sensor
exposure time is fixed. Select Auto-Iris if the video shows flickering or rolling bands due to 50 Hz or 60 Hz lighting. Most lighting situations
do not require this setting.
5. Select the Exposure Optimization setting: Normal or Action. These are optimizations of the Digital Exposure control.
Normal: This setting is for very bright scenes and exposure time is very short. As the scene becomes less bright, the exposure time is
increased until the maximum exposure time is reached. Normal is the default setting.
Action: This setting operates similar to Normal except the short exposure times are used for both bright and mid-level lighting. This
minimizes the blur in video caused by moving objects. For very low light scenes, Action optimization operates the same as Normal,
increasing the exposure time until the maximum exposure time is reached.
43
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Set the Exposure Compensation setting. Move the slider bar to the right to brighten the video, or move it to the left to darken the video. The
exposure compensation range is –100 to 100; the default setting is 0 (zero).
7. Color cameras only: Set the Max Exposure Time and Night Max Exposure Time.
Max Exposure Time: This setting controls the maximum time in milliseconds that an image is exposed during daytime conditions.
Decreasing Max Exposure Time reduces the blur caused by fast moving objects as the light dims, but it also reduces the light sensitivity of
the camera. The exposure range is 1 to 500 msec; the default setting is 33.3 msec.
Night Max Exposure Time: This setting controls the maximum time in milliseconds that an image is exposed during dim light, such as
nighttime conditions. Increase this time to increase the light sensitivity of the camera. The exposure range is 1 to 500 msec; the default
setting is 120 msec.
8. Day /night cameras only: Set the Day Max Exposure Time and Night Exposure Time.
Day Max Exposure Time: This setting controls the maximum time in milliseconds that an image is exposed when the camera is in
Day (Color) mode. Decreasing Max Exposure Time reduces the blur caused by fast moving objects as the light dims, but it also reduces the
light sensitivity of the camera. The exposure range is 1 to 500 msec; the default setting is 33.3 msec.
Night Max Exposure Time: This setting controls the maximum time in milliseconds that an image is exposed when the camera is in
Night (black-white) mode. Increase this time to increase the light sensitivity of the camera. The exposure range is 1 to 500 msec; the
default setting is 120 msec.
9. Day/night cameras only: Set the Day Exposure Time and the Night Exposure Time.
Day Exposure Time: This setting is the maximum time in milliseconds that an image is exposed during daytime conditions. Decreasing
exposure time decreases the light sensitivity of the scene and reduces the blur caused by fast moving objects; however, it increases the
amount of noise in the scene. The day maximum exposure time range is 1 to 500 msec; the default setting is 33.3 msec.
Night Exposure Time: This setting is the maximum time in milliseconds that an image is exposed during nighttime (black-white)
conditions. Increase the exposure time to increase light sensitivity of the scene. The night maximum exposure time range is 1 to 500 msec;
the default setting is 120 msec.
10. Day/night cameras only: Set the Day Night mode to Auto or Manual.
Auto: This setting automatically controls the IR cut filter determined by the Transition Level and the Transition Detect settings.
Manual: This setting sets the IR filter to a fixed position. The filter can be set to the Day (color) position or the Night (black-white) position.
Refer to the following section for more information:
•
C2963M-C (8/10)
44
Download from Www.Somanuals.com. All Manuals Search And Download.
SELECTING MANUAL EXPOSURE SETTINGS
Figure 31. Manual Exposure Page
1. Place your mouse pointer over the Imaging tab.
2. Select Exposure from the drop-down menu.
3. Select the Manual mode.
4. Move the Analog Gain slider to the desired position. Increasing the gain increases the brightness of the image, but it also increases the
amount of noise in the image. The analog gain range is 1.00 to 15.75; the default setting is 1.00.
5. Move the Exposure Time slider to the desired position. This setting is the maximum time in milliseconds that the sensor is exposed to the
light. Decreasing the maximum exposure time decreases the light sensitivity. The exposure time range is 0.01 to 1000 msec; the default
setting is 15 msec.
6. Day/night cameras only: Set the Day Night Position setting.
Day: Sets the IR filter to the Day (color) position.
Night: Sets the IR filter to the Night (black-white) position.
Refer to the following section for more information:
•
45
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
DAY NIGHT SETTINGS
The Day Night mode controls the position of the IR cut filter, which determines the color or black-white setting of the camera. The Day Night
mode settings change depending on the Exposure settings. If the camera is set to Auto Exposure mode, the Day Night mode can be set to Auto or
Manual and all of the respective settings are available. If the camera is set to Manual Exposure, the only available Day Night mode setting is
Position, which sets the IR filter to either the Day (color) position or the Night (black-white) position.
DAY NIGHT AUTO AND MANUAL MODES
DAY NIGHT AUTO MODE
The Day Night Auto mode setting automatically controls the IR cut filter depending on the Transition Level and Transition Detect Time settings.
Transition Level: Determines when the camera changes from day mode (color) to night mode (black-white). Move the slider to the left or right
to change the transition level to a lighter or darker setting. Select a lighter transition level setting if you want the camera to change modes at a
high lux setting. Use the default setting of 4 for normal day/night operation. Use a darker transition level to change modes at a low lux setting.
Table A. Lux Transition Points for Incandescent Lighting
Transition Level
Setting
Day to Night
Transition Point
Lighter
1
2
3
4
5
50 ~ 25 lux
25 ~ 12.5 lux
12.5 ~ 6.25 lux
6.25 ~ 3.125 lux
3.125 ~ 1.5 lux
Darker
Transition Detect Time (sec): Controls the length of time the camera is exposed to a light level before it changes to color or black-white mode.
This setting is useful for dark scenes where a bright light is momentarily introduced in the scene (for example, when a car with its headlights
turned on passes the camera scene).
DAY NIGHT MANUAL MODE
The Day Night Manual mode sets the IR cut filter to a fixed position depending on the Position setting. Available settings include Day and Night.
Day: Sets the IR filter to the Day (color) position.
Night: Sets the IR filter to the Night (black-white) position.
NOTE: Position is the only available Day Night setting if the camera exposure is set to Manual.
C2963M-C (8/10)
46
Download from Www.Somanuals.com. All Manuals Search And Download.
CONFIGURING AUTO FOCUS SETTINGS
Figure 32. Auto Focus Page
1. Place your mouse pointer over the Imaging tab.
2. Select Focus from the drop-down menu.
3. Select the Auto mode.
4. Set the Temperature Change Refocus setting. The camera is programmed to run a quick automatic focus sequence when the internal
temperature sensor of the camera detects an environmental temperature change of 41°F (5°C). This focus sequence adjusts the center
focal point of the scene to maintain optimal focus. The default setting is On; select Off to turn off this setting.
5. Day/night cameras only: Set the Day/Night Switch Refocus setting. The default setting for the Day/Night Switch Refocus is Off. Select On
if the camera’s focal length is greater than ~25 mm or the night scene uses mostly IR lighting. The best method to determine if the day/night
refocus should be enabled is to test the camera with the daytime light conditions, and then test it again with the nighttime light conditions.
When enabled (On) this setting refocuses the camera when the camera changes from day mode (color) to night mode (black-white) or vice
versa. For example, if the camera changes from day mode to night mode, the imager automatically adjusts the back focus for the change in
light.
6. If required, use one of the following buttons to adjust the focus:
Full Range Auto-Focus: The camera starts a full-range search to find the optimal focal point for the scene.
Quick Auto-Focus: The camera searches for the optimal focal point in a limited range.
Restore Setings to Defaults: The camera resets the auto focus to the factory default setting.
47
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
CONFIGURING MANUAL FOCUS SETTINGS
Figure 33. Manual Focus Page
NOTE: It is recommended to set the focus to Manual when using analytics. If the focus is set to Auto, significant background changes will occur
when the camera automatically adjusts to different points within a scene resulting in frequently changing image sharpness. This may cause
problems with scene recognition, which will suspend analytics operation or cause false alarms.
1. Place your mouse pointer over the Imaging tab.
2. Select Focus from the drop-down menu.
3. Select the Manual mode.
4. Set one of the following settings:
Day Manual Focus Position: (Available only with day/night cameras.) This is the position of the focus mechanism when the IR cut filter
is applied. The day mode focus position range is 0 to 100.
Night Manual Focus Position: (Available only with day/night cameras.) This is the position of the focus mechanism when the IR cut filter
is removed. The night mode focus position range is 0 to 100.
Manual Focus Position: (Available only with color cameras.) This is the manual setting of the focus mechanism. The focus range is
0 to 100.
5. Set the Manual Focus Position. The focus range is 0 to 100.
6. If required, click the Restore Settings to Defaults button to reset the focus to the factory default setting.
C2963M-C (8/10)
48
Download from Www.Somanuals.com. All Manuals Search And Download.
SETTING TONE MAP OPTIONS
Figure 34. Tone Map Page
1. Place your mouse pointer over the Imaging tab.
2. Select Tone Map from the drop-down menu.
3. Select the Optimization setting:
Normal (H.264): If the compression standard for the primary stream is H.264, set Optimization to Normal (H.264). This is the default
setting.
Photographic (JPEG): If the compression standard for the primary stream is JPEG, set Optimization to Photographic (JPEG).
4. Move the Tone Map sliders to adjust the following image settings:
Black Clip Percent: Adjusts the percent of pixels set to black. Move the slider to the right to darken the scene by increasing the number
of pixels that are mapped to absolute black. The black clip percent range is 0 to 25; the default setting is 0.5.
White Clip Percent: Adjusts the percent of pixels set to white. Move the slider to the right to lighten the scene by increasing the number
of pixels that are mapped to absolute white. The white clip range is 0 to 25; the default setting is 0.5.
Gamma Correction: Adjusts the details in the light and dark areas of the scene. Move the slider to the left to expose more detail in the
light areas of the scene; move the slider to the right to expose more detail in the dark areas of the scene. The gamma corrector range is
0.1 to 3.0; the default setting is 2.2.
5. If required, click the Restore Settings to Defaults button to reset the Tone Map to the factory default setting.
49
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
SELECTING AUTO WHITE BALANCE SETTINGS
Figure 35. Auto White Balance Page
1. Place your mouse pointer over the Imaging tab.
2. Select White Balance from the drop-down menu.
3. Select the Auto mode.
4. Move the sliders to adjust the following settings in Auto mode:
Red Gain Adjust: Adjusts the image output in the red range. Move the slider to the right to increase the red level; move the slider to the
left to decrease the red level. As you move the slider, you will see the color change on your monitor. The auto range of adjustment is –
1.0 to 1.0; the default setting is 0 (zero).
Green Gain Adjust: Adjusts the image output in the green range. Move the slider to the right to increase the green level; move the slider
to the left to decrease the green level. As you move the slider, you will see the color change on your monitor. The auto range of adjustment
is –1.0 to 1.0; the default setting is 0 (zero).
Blue Gain Adjust: Adjusts the image output in the blue range. Move the slider to the right to increase the blue level; move the slider to
the left to decrease the blue level. As you move the slider, you will see the color change on your monitor. The auto range of adjustment is –
1.0 to 1.0; the default setting is 0 (zero).
5. If required, click the Restore Settings to Defaults button to reset the white balance to the factory default setting.
C2963M-C (8/10)
50
Download from Www.Somanuals.com. All Manuals Search And Download.
SELECTING MANUAL WHITE BALANCE SETTINGS
Figure 36. Manual White Balance Page
NOTE: Manual white balance is recommended only for indoor applications that have a single, unchanging primary light source.
1. Place your mouse pointer over the Imaging tab.
2. Select White Balance from the drop-down menu.
3. Select the Manual mode.
4. Move the sliders to adjust the following settings in Manual mode:
Red Gain: Adjusts the image output in the red range. Move the slider to the right to increase the red level; move the slider to the left to
decrease the red level. As you move the slider, you will see the color change on your monitor. The manual range of adjustment is 0 to 32;
the default setting is 1.
Green Gain: Adjusts the image output in the green range. Move the slider to the right to increase the green level; move the slider to the
left to decrease the green level. As you move the slider, you will see the color change on your monitor. The manual range of adjustment is
0 to 32; the default setting is 1.
Blue Gain: Adjusts the image output in the blue range. Move the slider to the right to increase the blue level; move the slider to the left to
decrease the blue level. As you move the slider, you will see the color change on your monitor. The manual range of adjustment is 0 to 32;
the default setting is 1.
5. If required, click the Restore Settings to Defaults button to reset the white balance to the factory default setting.
51
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
TURNING ON WINDOW BLANKING
Figure 37. Window Blanking Page
1. Place your mouse pointer over the Imaging tab.
2. Select Window Blanking from the drop-down menu.
3. Select the On option for Window Blanking.
4. Draw a window in the Live Preview area of the page:
a. Hold down the left mouse button.
b. Drag the mouse diagonally across the area you want to blank.
c. A color-coded box appears in the Edit Window section of the page that is the same color as the window drawn in the Live Preview
area.
NOTE: Up to four blanked windows can be defined, but the blanked area cannot exceed 50 percent of the field of view.
5. To resize the window, click and drag one or more of the points until the window is the desired shape and size.
6. Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
TURNING OFF WINDOW BLANKING
1. Place your mouse pointer over the Imaging tab.
2. Select Window Blanking from the drop-down menu.
3. Select the Off option for Window Blanking.
4. Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
DELETING A WINDOW BLANKING AREA
1. Place your mouse pointer over the Imaging tab.
2. Select Window Blanking from the drop-down menu.
3. In the Edit Window area of the page, click the check box next to the window blanking area you want to delete.
4. Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
C2963M-C (8/10)
52
Download from Www.Somanuals.com. All Manuals Search And Download.
A/V Streams Tab
Use the A/V Streams tab to configure the video and audio streams for the camera. The A/V Streams tab includes a Video Presets page, a Video
Configuration page, and an Audio Configuration page.
Video Presets
The Video Preset page includes three fully-configured video presets, which include primary and secondary video stream settings for easy setup.
These presets may also be used as a starting point for a custom video configuration. These preset configurations vary depending on camera
model.
Video Configuration
The Video Configuration page allows you to customize the compression, resolution, image rate, and bit rate of the video streams. The default
names for the streams are Primary Stream and Secondary Stream. Although each stream can be configured independently, the settings of one
stream can limit the options available to the other stream, depending on the processing power used.
NOTE: Always configure the primary stream before the secondary stream. The primary stream should always be the most resource-intensive of
the streams.
Audio Configuration
The Audio Configuration page allows you to setup an external audio device. The default setting for Audio is disabled, which means that no audio
is transmitted from the camera. When enabled, audio is transmitted from the camera to the PC. Based on your system configuration, images and
audio may not be synchronized.
Not all camera models are equipped with an internal audio device. Refer to the specifications for your camera model for information.
NOTE: Improper use of audio/visual recording equipment may subject you to civil and criminal penalties. Applicable laws regarding the use of
such capabilities vary between jurisdictions and may require, among other things, express written consent from the recorded subjects. You are
solely responsible for insuring strict compliance with such laws and for strict adherence to any/all rights of privacy and personalty.
Refer to the following sections for more information:
•
•
•
•
•
•
•
•
•
•
•
•
53
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
SELECTING A VIDEO PRESET CONFIGURATION
Figure 38. Select Video Preset Configuration Page
1. Place your mouse pointer over the A/V Streams tab.
2. Select the Video Preset option from the drop-down menu.
3. Click the button next to the video preset stream configuration (High, Medium, or Low) that you want to select.
4. Click the Save button to save the settings, or click the Reset button to clear your selection without saving it.
C2963M-C (8/10)
54
Download from Www.Somanuals.com. All Manuals Search And Download.
CONFIGURING A CUSTOM VIDEO STREAM CONFIGURATION
Figure 39. Custom Video Stream Configuration Page
1. Place your mouse pointer over the A/V Streams tab.
2. Select Video Configuration from the drop-down menu.
3. Click both of the Clear buttons to delete the primary and secondary streams settings.
4. Optional: In the Primary Stream section, type a user-friendly name in the Name box (2 to 64 characters). A user-friendly name makes it
easier to recognize the stream (for example, Live and Recording).
5. Configure the Compression Standard, Resolution, Image Rate, and Bit Rate settings for the primary stream.
NOTE: The compression standard, resolution, image rate, and bit rate settings are dependent on each other. You must first decide the
priority setting before you configure a stream. For example, if you want an image rate of 30 ips, set the image rate before you configure the
other settings.
6. Repeat steps 3 through 5 for the Secondary stream.
7. Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
COMPRESSION STANDARDS
JPEG: A commonly used video compression scheme, also known as MJPEG. JPEG has the least impact on the camera’s processor, but it requires
the most bandwidth.
H.264: A new version of MPEG-4 compression used in high-definition video players such as Blu-ray™ and HD-DVD. H.264 is the most
processor-intensive, but it requires the least amount of bandwidth.
55
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
AVAILABLE CAMERA RESOLUTION
Refer to the following table for the resolution capabilities of your camera model
Table B. Available Camera Resolution
Camera Model
1.3 Megapixel 2.1 Megapixel
—
1920 x 1080
1600 x 1200
1280 x 1024
1280 x 960
1280 x 720
800 x 600
640 x 512
640 x 480
640 x 352
480 x 368
480 x 272
320 x 256
320 x 240
320 x 176
—
1280 x 1024
1280 x 960
1280 x 720
800 x 600
640 x 512
640 x 480
640 x 352
480 x 368
480 x 272
320 x 256
320 x 240
320 x 176
Available
Resolutions
IMAGE RATE
The image rate is the number of images per second (ips) available for the video stream configuration. Available image rates are 30, 25, 24, 15,
12.5, 12, 10, 8, 7.5, 6, 5, 4, 3, 2.5, 2, and 1.
NOTE: The maximum image rate setting might not be obtainable due to the programmed compression standard and the resolution of the stream.
Refer to the following section for more information:
•
BIT RATE
The bit rate is the quality of the video stream (rendered in kilobits per second). The higher the value, the higher the video quality and bandwidth
required.
NOTE: When you change any of the video stream configuration settings, the camera automatically adjusts the bit rate. If you manually reduce
the bit rate lower than the camera's automatic setting, the image quality might be reduced and the stream selection options might be limited.
I-FRAME INTERVAL
The I-frame interval configures the number of partial frames that occur between full frames in the video stream. For example, in a scene where a
door opens and a person walks through, only the movements of the door and the person are stored by the video encoder. The stationary
background that occurs in the previous partial frames is not encoded, because no changes occurred in that part of the scene. The stationary
background is only encoded in the full frames. Partial frames improve video compression rates by reducing the size of the video. As the I-frame
interval increases, the number of partial frames increases between full frames. Higher values are only recommended on networks with high
reliability. This setting is only available with H.264.
C2963M-C (8/10)
56
Download from Www.Somanuals.com. All Manuals Search And Download.
QUALITY OF SERVICE FOR DIFFERENTIATED SERVICES CODE POINT
Quality of Service (QoS) for Differentiated Services Code Point (DSCP) is a code that allows the network to prioritize the transmission of different
types of data. This setting is only available with H.264.
NOTES:
•
•
If you are not familiar with DSCP, contact your network administrator before changing this setting.
Your network must be configured to use QoS. If you are unsure if your network is QoS-aware, contact your network administrator.
ENDURA SIGNING
Enabling the Endura Signing feature allows an Endura® system to authenticate video from an Endura recorded stream. This setting is only
available with H.264.
RATE CONTROL
The rate control setting determines the bit rate and quality of each frame in the video stream. There might be a trade-off between image quality
and the resources required for video storage when selecting a rate control setting.
CBR: The constant bit rate (CBR) streams video at a fixed number of bits per second. CBR uses the full capacity of the bit rate setting for scenes
with or without motion. Video is always streamed at the user bit rate setting.
PROFILE
The profile defines the subset of bit stream features in an H.264 stream, including color reproduction and additional video compression. It is
important that the selected profile is compatible with the recording device so that a stream can be decoded and viewed.
Baseline: A simple profile with a low compression ratio. A baseline profile is compatible with more recorders but uses more bits to compress
quality video than the other profiles. This profile supports I-frames and P-frames. Use the baseline profile in applications with limited scene
changes; for example, an indoor scene with a single, unchanging primary light source and minimal motion.
Main: An intermediate profile with a medium compression ratio. Main is the default profile setting. This profile is compatible with most
recorders and uses fewer bits to compress video than the baseline profile; however, it uses more bits than the high profile. The main profile
supports I-frames, P-frames, and B-frames.
High: A complex profile with a high compression ratio. This is the primary profile for high-definition television applications; for example this is
the profile adopted for Blu-ray and HD-DVD. The high profile supports I-frames, P-frames, and B-frames.
GOP STRUCTURE
The group of pictures (GOP) structure is the sequence in which frames are placed within a video stream. The GOP structure always includes
intra-coded frames (I-frames) and predictive coded frames (P-frames), but it can also include bi-directionally predictive coded frames (B-frames).
Each GOP structure starts with an I-frame: an image of the complete scene that is used as the reference frame in the structure. P-frames record
data changes that are different than the previous frame. This allows the video encoder to save space since the data of the I-frame is not
duplicated. B-frames not only capture data changes from the previous frame, but they also capture the data changes from the frame after the
B-frame. B-frames are more compressed than P-frames and require more processing power to be decoded.
The camera can be configured to use one of the following GOP structures:
IP: A compression that uses only I-frames and P-frames to provide low latency and a high level of decoder support. This GOP structure is
compatible with more recorders and decoders than IBBrBP.
IBBrBP: The most sophisticated H.264 compression available. IBBrBP provides the highest quality image at a given bit rate, but it also increases
the latency of the video and requires more processing power for decoders.
ADVANCED SHARPENING
The Advanced Sharpening setting enhances picture detail by sharpening the edges in the picture. When this mode is enabled, there is a trade-off
between image quality and the resources required for processing power. The maximum camera resolution and image rate will not be available,
but the edges of the image seem sharper. Only use this setting if you cannot achieve the sharpness level you want by adjusting the digital
processing settings of the camera. The default setting for Advanced Sharpening is Off.
57
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
SELECTING THE AUDIO CONFIGURATION SETTINGS
To use audio with the camera you must have an audio device connected to the accessory port located on the back of the camera. Once the device
is connected, audio can only be enabled through the primary stream.
Audio and video may not be synced when viewing and listening to the primary stream through a Web browser. You may experience a
three-second delay in video when viewing the primary stream with audio.
NOTE: Improper use of audio/visual recording equipment may subject you to civil and criminal penalties. Applicable laws regarding the use of
such capabilities vary between jurisdictions and may require, among other things, express written consent from the recorded subjects. You are
solely responsible for insuring strict compliance with such laws and for strict adherence to any/all rights of privacy and personalty.
Figure 40. Audio Configuration Page
1. Place your mouse pointer over the A/V Streams tab.
2. Select the Audio Configuration option from the drop-down menu.
3. Select the Enabled option in the Audio section.
4. Select the audio device setting from the Audio Device drop-down box.
USB Line In: Enables audio from a microphone connected to the USB accessory port.
Native Line In: (Only available with specific Sarix™ technology products that have built-in audio. Refer to the specifications for your
product model for information.) Enables audio from a microphone connected to the audio-in connector.
Native Microphone In: (Only available with specific Sarix technology products that have built-in audio. Refer to the specifications for
your product model for information.) Enables audio from the internal microphone.
5. Select the sample rate from the Sample Rate drop-down box. The sample rate is the quality of the audio stream (rendered in hertz per
second). The higher the value, the higher the audio quality. Available sample rate settings are 8000, 11025, 16000, 22050, 32000, 44100,
and 48000 Hz. The default setting is 8000 Hz.
6. Select the encoding method for the audio device from the Encoding drop-down box. Available encoding methods are PCMU, PCMA, and
PM16. The default setting is PCMU.
7. Set the sensitivity of the input level by moving the Input Level slider. Move the slider to the right to increase the sensitivity level; move it to
the left to decrease the sensitivity level. For example, if the camera is installed in a noisy environment or the connected microphone has a
built-in line amplifier, set the sensitivity to a low setting. The setting range is 0 to 100.
NOTE: Do not use the mute button on an audio device, as it will override the audio software settings. To mute the audio device, select the
Mute option located on the Audio Configuration page.
8. Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
C2963M-C (8/10)
58
Download from Www.Somanuals.com. All Manuals Search And Download.
Users Tab
Use the Users tab to create and manage user accounts and to change the way the camera manages the users settings.
General Settings
Use the general settings page to set the public user access level. This access level is a predefined set of user permissions that allow the camera
to be accessed without logging on. The permission levels are Operator, Viewer, and Disabled.
The General Settings page also allows you to change the way the camera manages users and groups settings. These settings can be managed on
a camera-to-camera basis or by using a centralized server to apply changes to multiple cameras. General settings for users and groups include
Standalone, Node, and Mixed settings. An example of a Mixed management mode would be using a Lightweight Directory Access Protocol
(LDAP) server like Microsoft® Active Directory for authentication.
Users
User accounts are created to limit the permissions of individuals who are logged onto the camera. The Users page also includes four predefined
access level settings that include Administrator, Manager, Operator, and Viewer permissions.
Refer to the following sections for more information.
•
•
•
•
59
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
SELECTING THE USERS AND GROUPS SETTINGS
Figure 41. General Settings Page for Users
WARNING: The Node and Mixed settings are advanced controls. Consult your network administrator to obtain the required information.
1. Place your mouse pointer over the Users tab.
2. Select General Settings from the drop-down menu.
3. Select an access level from the Public User Access Level drop-down menu.
Disabled: The public user has no permissions and cannot access the live view page without a password. The Login screen will appear
when the camera's IP address is typed in the address bar of a Web browser.
Viewers: The permissions for this user are view video and API access. Viewers is the default setting.
Operators: The permissions for this user are view video and API access.
4. Select a user and group management mode by clicking one of the following options:
Standalone: The camera manages its users and groups locally. Any changes to users and groups affect only the camera that you are
accessing. Standalone is the default setting.
Node: The camera uses a centralized server to manage users and groups. In this mode, the users and groups page is disabled and all
management is done on the central server. Any changes to users and groups affect all cameras connected to the central server.
When you click the Node option, a Server box appears. Click in the Server box, and then type the name of the central server to manage
users and groups.
Mixed: The camera verifies user names and passwords against a central server but manages the group settings locally. This is useful if you
want to use a departmental or corporate server for user names and passwords. In this mode, the settings on the users page are limited, and
any changes to user names and passwords are done on the Lightweight Directory Access Protocol (LDAP) server. While changes to user
names and passwords affect all cameras connected to the LDAP server, group permissions must be managed from each camera
individually.
When you click the Mixed option, boxes appear for the LDAP Server and Base DN. Click in the LDAP Server and Base DN boxes, and type
the necessary information in each box.
5. Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
C2963M-C (8/10)
60
Download from Www.Somanuals.com. All Manuals Search And Download.
CREATING A NEW USER
Figure 42. Users Page
1. Place your mouse pointer over the Users tab.
2. Select Users from the drop-down menu.
3. Select the Access Level for the user.
Admins: This user has access to all camera settings.
Managers: This user has access to all settings except they cannot modify a user’s permissions or restore factory default settings.
Operators: The permissions for this user are view video, PTZ functions, and API access.
Viewers: The permissions for this user are view video and API access.
4. Click in the Username box and type a user name (2 to 23 alphanumeric characters). User names are not case-sensitive and are saved in
lowercase characters.
5. Click in the Password box and type a password (4 to 16 alphanumeric characters). Passwords are case-sensitive.
6. Click in the Retype Password box and retype your password.
7. Click in the First Name box and type the user’s first name (1 to 32 alphanumeric characters).
8. Click in the Last Name box and type the user’s last name (1 to 32 alphanumeric characters).
9. Click in the Email box and type the user’s email address.
10. Click the Save button to save the settings and create a new user (the new user profile appears in the box on the left side of the page), or
click the Reset button to clear all of the information you entered without saving it.
61
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
EDITING A USER
1. Place your mouse pointer over the Users tab.
2. Select Users from the drop-down menu.
3. Click the user profile that you want to edit from the box on the left side of the page.
4. If required, select a different Access Level for the user.
5. Double-click in each of the text boxes to highlight the text. Type the new information in each text box.
NOTE: The Username cannot be modified; this text box is read-only.
6. Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
DELETING A USER
1. Place your mouse pointer over the Users tab.
2. Select Users from the drop-down menu.
3. Click the user profile that you want to delete from the defined users section located in the box on the left side of the page.
4. Click the Delete User button. A dialog box appears with the message “Are you sure you want to delete the user?”
5. Click OK. The user profile is deleted from the defined user profiles section.
NOTE: The “admin” user cannot be deleted.
C2963M-C (8/10)
62
Download from Www.Somanuals.com. All Manuals Search And Download.
Events Tab
Use the Events tab to configure camera events and analytics.
Events are activated by user-defined event sources that tell the device how to react when an event occurs. Event handlers are the actions that
the device takes when an event occurs. For example, a system source can be configured to send email to an operator if the system shuts-down
and restarts.
Sources
The camera supports one physical input alarm source, a system source, and a timer source. The Alarm source is the camera input for an external
signaling device, such as a door contact or motion detector. The System source is activated when the camera restarts. The Timer source is a
user-defined event that activates an event after a specified amount of time. For example, the timer can be activated every 60 seconds to save an
image to an SD card.
Handlers
The device supports a Send Email handler, a “Write JPEG to SD Card handler,” and an “Upload JPEG to FTP Server handlers.” The Send Email
handler sends an email to a defined email address when an event is activated. The “Write JPEG to SD Card” saves a JPEG of the activated event
to an SD card. The “Upload JPEG to FTP Server” saves a JPEG of the activated event to a defined FTP server.
Analytic Configuration
Pelco analytics can be configured and enabled using a standard Web browser. The device is preloaded with user-configurable behaviors and is
capable of running several behaviors at the same time. The number of behaviors is limited to the available processing power of the device.
Available processing power is determined by the settings for compression standards, resolution, image rate, bit rate, and analytic configuration.
Pelco analytics are also compatible with Endura® or a third-party system that supports Pelco’s Analytics API system. Refer to the specific product
documentation for instructions on how to configure and enable Pelco analytics.
NOTE: Analytic alerts can be seen in the event stream, but alarms are only transmitted through the analytics API.
Models are also available with ObjectVideo® (OV) Suites. OV Suites require an OV ready-compliant system with an OV Ready™ video
management system to configure and enable the OV Analytic Suites that are preloaded on the camera. Refer to the ObjectVideo documentation
for instructions on how to configure and enable OV analytics.
Pelco analytics include the following behaviors:
Abandoned Object: Detects objects placed in a defined zone and triggers an alarm if the object remains in the zone longer than the
user-defined time allows.
Adaptive Motion: Detects and tracks objects that enter a scene and then triggers an alarm when the objects enter a user-defined zone. The
objects are monitored until they exit the scene.
Camera Sabotage: Detects contrast changes in the field of view. An alarm is triggered if the lens is obstructed with spray paint, a cloth, or
covered with a lens cap. Any unauthorized repositioning of the camera also triggers an alarm.
Directional Motion: Generates an alarm in a high traffic area when a person or object moves in a specified direction. For example, a camera is
pointed at an exit door. If someone tries to enter through the exit door, an alarm triggers.
Loitering Detection: Identifies when people or vehicles remain in a defined zone longer than the user-defined time allows. This behavior is
effective for real-time notification of suspicious behavior around ATMs, stairwells, and school grounds.
Object Counting: Counts the number of objects that enter a defined zone or cross a defined trip wire. This behavior can be used to count people
at a store entrance/exit or inside a store where the traffic is light.
Object Removal: Triggers an alarm if an object is removed from a user-defined zone. This behavior is ideal for customers who want to detect
the removal of high-value objects, such as a painting from a wall or a statue from a pedestal.
Stopped Vehicle: Detects vehicles stopped near a sensitive area longer than the user-defined time allows. This behavior is ideal for parking
enforcement, suspicious parking, traffic lane breakdowns, and vehicles waiting at gates.
63
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
SOURCES
Figure 43. New Event Source Page
An event is a preprogrammed camera function that is automatically activated by an event source. The camera supports the following types of
event sources:
Alarm Source: The camera supports one alarm source. The sources are the camera inputs for external signaling devices, such as door contacts
or motion detectors.
System Source: A system source is activated when the camera restarts.
Timer Source: A timer source is a user-defined event. The user can program the timer to activate an event after a specified amount of time.
For example, the timer can be activated every 60 seconds to save an image to an SD card.
CREATING AN ALARM EVENT SOURCE
1. Place your mouse pointer over the Events tab.
2. Select Sources from the drop-down menu.
3. Click in the Name box and type a user-friendly name (2 to 23 alphanumeric characters).
4. Select Alarm from the Type drop-down menu.
5. Move the Dwell Time slider to set the amount of time in seconds that the alarm is active. The dwell time range is 0.1 to 200 seconds; the
default setting is 0.1.
6. Select either normal or reversed from the Polarity drop-down menu.
7. Select either true or false from the Supervised drop-down menu.
8. Click the Submit button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
C2963M-C (8/10)
64
Download from Www.Somanuals.com. All Manuals Search And Download.
CREATING A SYSTEM EVENT SOURCE
1. Place your mouse pointer over the Events tab.
2. Select Sources from the drop-down menu.
3. Click in the Name box and type a user-friendly name (2 to 23 alphanumeric characters).
4. Select System from the Type drop-down menu.
5. Select the Boot check box to activate an event when the camera reboots.
6. Click the Submit button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
CREATING A TIMER EVENT SOURCE
1. Place you mouse over the Events tab.
2. Select Sources from the drop-down menu.
3. Click in the Name box and type a user-friendly name (2 to 23 alphanumeric characters).
4. Select Timer from the Type drop-down menu.
5. Click in the Frequency box and type a number. Select seconds, minutes, hours, or days from the Frequency drop-down menu.
6. Click the Submit button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
EDITING AN EVENT SOURCE
1. Place your mouse pointer over the Events tab.
2. Select Sources from the drop-down menu.
3. Click the source profile that you want to delete from the defined source box located on the left side of the page.
4. Make any necessary changes to the available fields.
5. Click the Submit button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
DELETING AN EVENT SOURCE
1. Place your mouse pointer over the Events tab.
2. Select Sources from the drop-down menu.
3. Click the source profile that you want to delete from the defined source box located on the left side of the page.
4. Click the Delete Source button. A dialog box appears with the message “Are you sure you want to delete the source?”
5. Click OK. The source profile is deleted from the defined source box.
65
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
HANDLERS
Figure 44. New Event Handler Page
Event handlers are the actions that the camera takes when an event occurs. The camera supports the following event handlers:
Send Email: Sends an email to a defined email address when an event is activated. The Simple Mail Transfer Protocol (SMTP) server must be
configured to accept the camera’s IP address.
Write JPEG to SD Card: Saves a JPEG of the activated event to an SD card. An SD card must be installed in the device for this handler to
function.
NOTE: The SD card must be formatted as FAT32. Other formats are not compatible with the camera.
Upload JPEG to FTP Server: Saves a JPEG of the activated event to a defined FTP server.
C2963M-C (8/10)
66
Download from Www.Somanuals.com. All Manuals Search And Download.
CREATING AN EVENT HANDLER: SEND EMAIL
NOTE: To use email notification, the camera must be connected to a local area network (LAN) that maintains an SMTP mail server. Consult your
network administrator for information on configuring email notification on your local network.
1. Configure the SMTP server to send email.
2. Place your mouse pointer over the Events tab.
3. Select Handler from the drop-down menu.
4. Click in the Name box and type a user-friendly name (2 to 23 alphanumeric characters).
5. Select Send Email from the Type drop-down menu.
6. Click in the text boxes (To, From, Subject, and Message), and then type the necessary information in each text box.
7. Select the JPEG Snapshot box if you want to send a JPEG as an attachment.
8. Select the Attach Raw Event Data box if you want the email to include extra data about the event. For example, select this box if the event
is triggered by an alarm and you want to receive data about the state, time, or type of alarm.
9. If you do not want the handler activated every time an event occurs, set filters for the handler.
a. Select the day(s) of the week on which you want emails to be sent.
b. Type times in the Start and End boxes for the days you have selected. Use time values in 24-hour notation (for example, use 0800 for
8:00 a.m., 1600 for 4:00 p.m.).
10. Select one or more event sources to send an email when those event sources are activated.
11. Click the Submit button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
Refer to the following sections for more information:
•
•
CREATING AN EVENT HANDLER: WRITE JPEG TO SD CARD
1. Install an SD card in the SD card slot located on the back of the camera.
NOTE: The SD card must be formatted as FAT32. Other formats are not compatible with the camera.
2. Place your mouse pointer over the Events tab.
3. Select Handlers from the drop-down menu.
4. Click in the Name box and type a user-friendly name (2 to 23 alphanumeric characters).
5. Select “Write JPEG to SD Card” in the Type drop-down menu.
6. The JPEG files saved to the SD card will be given file names that correspond to the date and time of the event. Select a time standard from
the “File name” drop-down menu.
7. Click in the Size limit box and type a number. Select Kilobytes, Megabytes, or Gigabytes from the Size Limit drop-down menu.
NOTE: Do not select a size limit that is larger than the amount of memory on the SD card. For example, if the SD card is 2 MB, do not
exceed 2 MB in the Size Limit box.
8. If you do not want the handler activated every time an event occurs, set filters for the handler.
a. Select the day(s) of the week on which you want JPEGs saved to the SD card.
b. Type times in the Start and End boxes for the days you have selected. Use time values in 24-hour notation (for example, use 0800 for
8:00 a.m., 1600 for 4:00 p.m.).
9. Select one or more sources to save a JPEG to the SD card when those event sources are activated.
10. Click the Submit button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
Refer to the following section for more information:
•
67
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
CREATING AN EVENT HANDLER: UPLOAD JPEG TO FTP SERVER
1. Place your mouse pointer over the Events tab.
2. Select Handlers from the drop-down menu.
3. Click in the Name box and type a user-friendly name (2 to 23 alphanumeric characters).
4. Select “Upload JPEG to FTP Server” in the Type drop-down menu.
5. Click in the Server box and type the server address (1 to 32 alphanumeric characters).
6. Click in the Username box and type the user’s name (1 to 32 alphanumeric characters).
7. Click in the Password box and type a password (4 to 16 alphanumeric characters).
8. Click in the Base Path box and type the base path (1 to 32 alphanumeric characters).
9. The JPEG files uploaded to the FTP server will be given file names that correspond to the date and time of the event. Select a time standard
from the “File name” drop-down menu.
10. If you do not want the handler activated every time an event occurs, set filters for the handler.
a. Select the day(s) of the week on which you want JPEGs saved to the FTP server.
b. Type times in the Start and End boxes for the days you have selected. Use time values in 24-hour notation (for example, use 0800 for
8:00 a.m., 1600 for 4:00 p.m.).
11. Select one or more sources to save a JPEG to the FTP server when those event sources are activated.
12. Click the Submit button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
Refer to the following section for more information:
•
CREATING AN EVENT HANDLER: OPEN/CLOSE RELAY
1. Place your mouse pointer over the Events tab.
2. Select Handlers from the drop-down menu.
3. Click in the Name box and type a user-friendly name (2 to 23 alphanumeric characters).
4. Select Open/Close Relay in the Type drop-down menu.
5. Move the On Time slider to set the amount of time that the relay will remain open. The time range is 0.1 to 200 seconds; the default setting
is 0.1.
6. Move the Off Time slider to set the amount of time that the relay will remain closed. The time range is 0.1 to 200 seconds; the default
setting is 0.1.
7. Click in the Pulse Count box and type a number.
8. If you do not want the handler activated every time an event occurs, set filters for the handler.
a. Select the day(s) of the week on which you want the relay opened/closed.
b. Type times in the Start and End boxes for the days you have selected. Use time values in 24-hour notation (for example, use 0800 for
8:00 a.m., 1600 for 4:00 p.m.).
9. Select one or more event sources to open/close the relay when those event sources are activated.
10. Click the Submit button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
Refer to the following section for more information:
•
C2963M-C (8/10)
68
Download from Www.Somanuals.com. All Manuals Search And Download.
EDITING AN EVENT HANDLER
1. Place your mouse pointer over the Events tab.
2. Select Handlers from the drop-down menu.
3. Click the handler profile that you want to delete from the defined handler box located on the left side of the page.
4. Make any necessary changes to the available fields.
5. Click the Submit button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
DELETING AN EVENT HANDLER
1. Place your mouse pointer over the Events tab.
2. Select Handlers from the drop-down menu.
3. Click the handler profile that you want to delete from the defined handler box located on the left side of the page.
4. Click the Delete Handler button. A dialog box appears with the message “Are you sure you want to delete the handler?”
5. Click OK. The handler profile is deleted from the defined handler box.
EXAMPLE HANDLER FILTER SETUP
If you do not want a handler activated every time an event occurs, use the filter fields to limit handlers. For example, you only want a handler
activated when an event occurs after business hours. Your business is open Monday through Saturday, 8:00 a.m. to 6:00 p.m., and it is closed on
Sunday.
1. Create a handler for Monday through Saturday:
a. Select the day filter fields Monday through Saturday.
b. Type 0000 in the Start box and 0800 in the End box.
c. Click the plus button (+) to add another time range. Type 1800 in the second Start box and type 2400 in the second End box.
d. Select the source(s) that activates the handler.
e. Click the Submit button to save the handler.
2. Create a second handler for Sunday:
a. Select Sunday from the day filter fields.
b. Do not set a Start time or End time as this is a 24-hour event.
c. Select the source(s) that activates the handler.
d. Click the Submit button to save the second handler.
69
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
ANALYTIC CONFIGURATION
NOTES:
•
•
•
This section explains how to configure and enable Pelco analytics using a Web browser.
Analytic alerts can be seen in the event stream, but alarms are only transmitted through the analytics API.
For information on how to receive analytic alerts for ObjectVideo Suites, refer to the ObjectVideo Web Console User Guide or the
ObjectVideo Web Console User Guide-Abridged. Both are available on the resource disc supplied with the camera.
Figure 45. Analytic Configuration Page
To configure an analytic behavior using a standard Web browser, you must create a profile, select the behavior for the profile, and then create the
zones to be monitored by the behavior.
Profiles: A profile extends the flexibility and power of a behavior. For each behavior, you can create several custom profiles that contain
different settings. With these profiles, you can set up different scenarios for the behavior. Depending on the behavior, each profile might focus on
a different zone, have different sensitivities, detect different object sizes, or trigger an alarm based on different types of motion.
Behaviors: A behavior analyzes objects within the camera’s field of view and can be configured to detect and trigger alarms automatically when
specific activity is detected. Available behaviors are based on the camera model. Examples of behaviors include Camera Sabotage, which
detects contrast changes in the field of view and triggers an alarm if the lens is obstructed or if the camera is repositioned; Adaptive Motion,
which detects and tracks objects that enter a user-defined zone; and Object Counting, which counts the number of objects that enter a defined
zone or cross a defined trip wire.
Zone: A zone is a defined boundary or area that is monitored by a configured behavior. A zone can be defined by a box, polygon, or tripwire, and
it can also include the direction of motion. These attributes are determined by the parameters of the selected behavior.
C2963M-C (8/10)
70
Download from Www.Somanuals.com. All Manuals Search And Download.
CREATING A NEW PROFILE
1. Place your mouse pointer over the Events tab.
2. Select Analytic Configuration from the drop-down menu.
3. Click the plus button (+) located in the Select Profile section.
4. Type a descriptive name for the profile in the Name box located in the Profile Settings section.
NOTE: Consider naming profiles based on their function. A more descriptive name makes it easier to recognize and locate a profile.
5. Select the Scene Type, Background, Fine Tuning, and Sensitivity settings from the drop-down menus located in the Profile Settings section.
6. Click the Calibrate Scene button to calibrate the scene.
NOTE: Set the perspective settings to reflect the camera’s angle. This information will make the object sizes you set on the next tab more
meaningful and help reduce the number of false alarms.
7. Select the behavior for the profile from the “Select behaviors” section.
8. Configure the settings for the behavior.
9. Click the Save button to save the profile. The new profile name appears in the Select Profile section.
REVISING A PROFILE
1. Place your mouse pointer over the Events tab.
2. Select Analytic Configuration from the drop-down menu.
3. Select the profile name from the Select Profile section. The settings for the profile appear.
4. Make the required changes to the profile settings.
5. Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
DELETING A PROFILE
1. Place your mouse pointer over the Events tab.
2. Select Analytic Configuration from the drop-down menu.
3. Select the profile name from the Select Profile section.
4. Click the minus button (–) located in the Select Profile section.
5. A dialog box opens and the following message appears: “Are you sure you want to delete the profile?”
6. Click the OK button to delete the profile.
71
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
CONFIGURING A BEHAVIOR
1. Place your mouse pointer over the Events tab.
2. Select Analytic Configuration from the drop-down menu.
3. Select a profile from the Select Profile section.
4. Select the behavior for the profile from the “Select behaviors” section.
5. Check the Activate Behavior box located in the “Settings for [behavior name]” section.
If the camera has enough resources, the behavior activates and a check mark appears to the left of the selected behavior(s), which is
located in the “Select behaviors” section.
If the camera does not have enough resources, the following message and instructions appear: “The camera does not have enough
processing power to activate this behavior. To free up needed resources, turn off one of the other behaviors or reconfigure the video
streams.”
6. Set up the zones for the behavior.
7. Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
DRAWING A ZONE
You can define up to 32 zones for each behavior. Each zone has a shape and direction. There are three types of drawing tools: Box, Polygon, and
Line. If a box or polygon is drawn to define the zone, any motion against the alarmed direction will trigger an alarm. If a line (trip wire) is drawn
to define the zone, any motion that crosses the line against the alarmed direction will trigger an alarm.
1. Place your mouse pointer over the Events tab.
2. Select Analytic Configuration from the drop-down menu.
3. Click a behavior located in the “Select behaviors” section.
4. Check the Activate Behavior box located in the “Settings for [behavior name]” section. A check mark appears to the left of the selected
behavior(s) located in the “Select behaviors” section.
5. Use the draw tools to define the zone.
6. Set the behavior-specific settings for the zone:
Name: Enter a descriptive name for the zone. Consider naming zones based on their location.
Enable alarm: Activates the alarm function. Select the check box to activate an alarm.
Direction: If the alarm is enabled, this setting defines the direction in which you want to detect and count moving objects and people
inside the defined zone. Direction settings include all directions (All, Up, Up-right, Right, Down-right, Down, Down-left, Left, and Up-left).
Alarm at: Defines the number of objects required to enter the zone or cross the trip wire to trigger an alarm.
Alarm severity: Defines the level of an alarm event. Settings include Minor, Normal, Major, and Critical
Dwell Time: Defines the time in seconds that the alarm-triggered zone turns to normal status. The default setting is 30 seconds.
Reset count after alarm: Rests the counter to zero after the count reaches the defined the number of objects required to trigger an alarm.
7. To draw another zone, repeat steps 5 through 7.
8. Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
C2963M-C (8/10)
72
Download from Www.Somanuals.com. All Manuals Search And Download.
ZONE DRAW TOOLS
Box: Tracks objects that move against the alarmed direction in a defined zone.
Polygon: Tracks objects that move against the alarmed direction in a defined zone.
Line: Tracks objects that cross a line (trip wire) against the alarmed direction.
Exclude Zone Box Tool: Ignores objects inside a defined zone.
Exclude Zone Polygon Tool: Ignores objects inside a defined zone.
Object Size Filter: Sets the minimum and maximum object size for a zone.
Drawing a Box
1. Hold down the left mouse button.
2. Drag the mouse diagonally across the area you want to define with a box.
3. A color-coded box appears to the right of the preview pane in the “Zone list.” The Zone box is the same color as the box drawn in the
preview pane.
4. To resize the box, click and drag one or more of the points until the box is the desired shape and size.
5. To move the box, click inside the box and drag it to the desired location.
Drawing a Polygon
A polygon is drawn with six points.
1. To define the first point of the polygon, click anywhere in the preview pane while holding down the left mouse button.
2. Drag the mouse across the preview pane, and then release the mouse button to define the second point of the polygon.
3. Click the second point and drag the mouse across the preview pane. Release the mouse button to define the third point of the polygon
4. Repeat this process to define points four through five.
5. To define the sixth point and to close the polygon, you must double-click the first point again.
6. To resize the polygon, click and drag one or more of the points until the polygon is the desired shape and size.
7. To move the polygon, click inside the polygon and drag it to the desired location.
Drawing a Line (Trip Wire)
A line is drawn with two points.
1. To define the first point of the line, click anywhere in the preview pane while holding down the left mouse button.
2. Drag the mouse across the preview pane, and then release the mouse button to define the second point of the line.
3. A color-coded box appears to the right of the preview pane in the “Zone list.” The Zone box is the same color as the line drawn in the
preview pane.
4. To resize the line, click and drag one of the points of the line unitil it is the desired length.
5. To move the line, click the line and drag it to the desired location.
73
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
DELETING A ZONE
1. Place your mouse pointer over the Events tab.
2. Select Analytic Configuration from the drop-down menu.
3. Click the behavior located in the “Select behaviors” section that you want to modify.
4. The settings for the behavior are displayed in the “Settings for [behavior name]” section.
5. In the “Zone list” area of the page, click the check box next to the zone you want to delete.
6. Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
C2963M-C (8/10)
74
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
IDE10 SERIES
MODELS
IDE10DN-0
Sarix indoor fixed dome network camera, extended platform, 1.3 megapixel, day/night, no lens,
smoked dome, with built-in Pelco analytics
IDE10DN-1
Sarix indoor fixed dome network camera, extended platform, 1.3 megapixel, day/night, no lens,
clear dome, with built-in Pelco analytics
IDE10DN8-1
Sarix indoor fixed dome network camera, extended platform, 1.3 megapixel, day/night, 2.8 ~ 8 mm
varifocal megapixel lens, clear dome, with built-in Pelco analytics
IDE10DN-OCP1
IDE10DN-OS1
IDE10DN-OSP1
Sarix indoor fixed dome network camera, extended platform, 1.3 megapixel, day/night, no lens, clear
dome, with built-in OV Event Counting Plus Suite
Sarix indoor fixed dome network camera, extended platform, 1.3 megapixel, day/night, no lens, clear
dome, with built-in OV Security Suite
Sarix indoor fixed dome network camera, extended platform, 1.3 megapixel, day/night, no lens, clear
dome, with built-in OV Security Plus Suite
REQUIRED SYSTEM
Pelco Analytics
Pelco Interface
Pelco Analytics API
Remote operation from an Endura® 2.0 (or later) system
Available for download at http://pdn.pelco.com
GENERAL
Imaging Device
1/3-inch (effective)
CMOS
Imager Type
Imager Readout
Progressive scan
1920 x 1080
50 dB
Maximum Resolution
Signal-to-Noise Ratio
Auto Iris Lens Type
Electronic Shutter Range
Wide Dynamic Range
White Balance Range
DC drive
1 ~ 1/10,000 sec
60 dB
2,000° to 10,000°K
Sensitivity
Color (1x/33 ms)
f/1.2; 2,850°K; SNR >24dB
0.50 lux
Color SENS (15x/500 ms)
Mono (1x/33 ms)
Mono SENS (15x/500 ms)
0.12 lux
0.25 lux
0.03 lux
ELECTRICAL
Port
RJ-45 connector for 100Base-TX; Auto MDI/MDI-X
Cat5 or better for 100Base-TX
Cabling Type
Power Input
24 VAC or PoE (IEEE 802.3af class 3)
Power Consumption
(camera only)
<7 W
Current Consumption
PoE
<200 mA maximum
24 VAC
<295 mA nominal; <390 mA maximum
Local Storage
Alarm Input
Micro SD
10 VDC maximum, 5 mA maximum
0 to 15 VDC maximum, 75 mA maximum
External 3-connector, 2.5 mm provides NTSC/PAL video output
Relay Output
Service Connector
75
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
MECHANICAL
Lens Mount
CS mount, adjustable
Pan/Tilt Adjustment
Pan
368°
Tilt
Rotate
160° (10° to 170°)
355°
VIDEO
Video Encoding
H.264 high, main, or base profile and MJPEG
Video Streams
Frame Rate
Up to 2 simultaneous streams; the second stream is variable based on the setup of the primary stream
Up to 30, 25, 24, 15, 12.5, 12, 10, 8, 7. 5, 6, 5, 4, 3, 2.5, 2, 1
(dependent on the coding, resolution, and stream configuration)
Available Resolutions
Resolution
MJPEG
H.264 High Profile
Aspect Maximum Recommended Maximum Recommended
MPx Width Height
Ratio
5:4
IPS
Bit Rate
10.0 Mbps
10.0 Mbps
10.0 Mbps
7.7 Mbps
5.2 Mbps
4.9 Mbps
3.6 Mbps
2.8 Mbps
2.0 Mbps
1.3 Mbps
1.2 Mbps
0.9 Mbps
IPS
Bit Rate
3.4 Mbps
3.0 Mbps
2.9 Mbps
2.0 Mbps
1.6 Mbps
1.5 Mbps
1.2 Mbps
1.0 Mbps
0.8 Mbps
0.5 Mbps
0.5 Mbps
0.3 Mbps
1.3
1.2
0.9
0.5
0.3
0.3
0.2
0.2
0.1
0.1
0.1
0.1
1280
1280
1280
800
640
640
640
480
480
320
320
320
1024
960
720
600
512
480
352
368
272
256
240
176
20.0 ips
20.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
20.0 ips
20.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
4:3
16:9
4:3
5:4
4:3
16:9
4:3
16:9
5:4
4:3
16:9
Supported Protocols
TCP/IP, UDP/IP (Unicast, Multicast IGMP), UPnP, DNS, DHCP, RTP, RTSP, NTP, IPv4, SNMP, QOS, HTTP,
HTTPS, LDAP (client), SSH, SSL, SMTP, FTP, mDNS (Bonjour®), and 802.1x (EAP)
Users
Unicast
Multicast
Up to 20 simultaneous users depending on resolution settings (2 guaranteed streams)
Unlimited users H.264 or MPEG-4
Security Access
Password protected
Software Interface
Pelco System Integration
Open IP Integration
Web browser view and setup, up to 16 cameras
Endura 2.0 (or later), Digital Sentry 4.2 (or later)
Pelco IP camera API
ENVIRONMENTAL
Operational Temperature
14° to 122°F (–10° to 50°C)
20% to 80%, noncondensing
Operational Humidity
PHYSICAL
Dimensions
5.4" D x 3.1" W x 3.0" H
(13.7 x 7.9 x 7.6 cm)
Weight (without lens)
2.00 lb (0.90 kg)
C2963M-C (8/10)
76
Download from Www.Somanuals.com. All Manuals Search And Download.
IDE20 SERIES
MODELS
IDE20DN-0
Sarix indoor fixed dome network camera, extended platform, 2.1 megapixel, day/night, no lens,
smoked dome, with built-in Pelco analytics
IDE20DN-1
Sarix indoor fixed dome network camera, extended platform, 2.1 megapixel, day/night, no lens,
clear dome, with built-in Pelco analytics
IDE20DN8-1
Sarix indoor fixed dome network camera, extended platform, 2.1 megapixel, day/night,
2.8 ~ 8 mm varifocal megapixel lens, clear dome, with built-in Pelco analytics
IDE20DN-OCP0
IDE20DN-OS0
IDE20DN-OSP0
IDE20DN-OCP1
IDE20DN-OS1
IDE20DN-OSP1
Sarix indoor fixed dome network camera, extended platform, 2.1 megapixel, day/night, no lens,
smoked dome, with built-in Object Video® (OV) Event Counting Plus Suite
Sarix indoor fixed dome network camera, extended platform, 2.1 megapixel, day/night, no lens,
smoked dome, with built-in OV Security Suite
Sarix indoor fixed dome network camera, extended platform, 2.1 megapixel, day/night, no lens,
smoked dome, with built-in OV Security Plus Suite
Sarix indoor fixed dome network camera, extended platform, 2.1 megapixel, day/night, no lens,
clear dome, with built-in OV Event Counting Plus Suite
Sarix indoor fixed dome network camera, extended platform, 2.1 megapixel, day/night, no lens,
clear dome, with built-in OV Security Suite
Sarix indoor fixed dome network camera, extended platform, 2.1 megapixel, day/night, no lens,
clear dome, with built-in OV Security Plus Suite
REQUIRED SYSTEM
Pelco Analytics
Pelco Interface
Pelco Analytics API
Remote operation from an Endura® 2.0 (or later) system
Available for download at http://pdn.pelco.com
Object Video Suites
OV ready-compliant system with OV Ready™ video management system
GENERAL
Imaging Device
1/3-inch (effective)
CMOS
Imager Type
Imager Readout
Progressive scan
1920 x 1080
50 dB
Maximum Resolution
Signal-to-Noise Ratio
Auto Iris Lens Type
Electronic Shutter Range
Wide Dynamic Range
White Balance Range
DC drive
1 ~ 1/10,000 sec
60 dB
2,000° to 10,000°K
Sensitivity
Color (1x/33 ms)
f/1.2; 2,850°K; SNR >24dB
0.50 lux
Color SENS (15x/500 ms)
Mono (1x/33 ms)
Mono SENS (15x/500 ms)
0.12 lux
0.25 lux
0.03 lux
77
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
ELECTRICAL
Port
RJ-45 connector for 100Base-TX; Auto MDI/MDI-X
Cat5 or better for 100Base-TX
Cabling Type
Power Input
24 VAC or PoE (IEEE 802.3af class 3)
Power Consumption
(camera only)
<7 W
Current Consumption
PoE
<200 mA maximum
24 VAC
<295 mA nominal; <390 mA maximum
Local Storage
Alarm Input
Micro SD
10 VDC maximum, 5 mA maximum
0 to 15 VDC maximum, 75 mA maximum
External 3-connector, 2.5 mm provides NTSC/PAL video output
Relay Output
Service Connector
MECHANICAL
Lens Mount
CS mount, adjustable
Pan/Tilt Adjustment
Pan
368°
Tilt
Rotate
160° (10° to 170°)
355°
VIDEO
Video Encoding
H.264 high, main, or base profile and MJPEG
Video Streams
Frame Rate
Up to 2 simultaneous streams; the second stream is variable based on the setup of the primary stream
Up to 30, 25, 24, 15, 12.5, 12, 10, 8, 7. 5, 6, 5, 4, 3, 2.5, 2, 1
(dependent on the coding, resolution, and stream configuration)
Available Resolutions
Resolution
MJPEG
H.264 High Profile
Aspect Maximum Recommended Maximum Recommended
MPx Width Height
Ratio
16:9
4:3
IPS
Bit Rate
10.0 Mbps
10.0 Mbps
10.0 Mbps
10.0 Mbps
10.0 Mbps
7.7 Mbps
5.2 Mbps
4.9 Mbps
3.6 Mbps
2.8 Mbps
2.0 Mbps
1.3 Mbps
1.2 Mbps
0.9 Mbps
IPS
Bit Rate
6.0 Mbps
4.0 Mbps
3.3 Mbps
3.0 Mbps
2.9 Mbps
2.0 Mbps
1.6 Mbps
1.5 Mbps
1.2 Mbps
1.0 Mbps
0.8 Mbps
0.5 Mbps
0.5 Mbps
0.3 Mbps
2.1
1.9
1.3
1.2
0.9
0.5
0.3
0.3
0.2
0.2
0.1
0.1
0.1
0.1
1920
1600
1280
1280
1280
800
1080
1200
1024
960
720
600
512
480
352
368
272
256
240
176
30.0 ips
20.0 ips
20.0 ips
20.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
20.0 ips
20.0 ips
20.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
30.0 ips
5:4
4:3
16:9
4:3
640
5:4
640
4:3
640
16:9
4:3
480
480
16:9
5:4
320
320
4:3
320
16:9
Supported Protocols
TCP/IP, UDP/IP (Unicast, Multicast IGMP), UPnP, DNS, DHCP, RTP, RTSP, NTP, IPv4, SNMP, QOS, HTTP,
HTTPS, LDAP (client), SSH, SSL, SMTP, FTP, mDNS (Bonjour), and 802.1x (EAP)
C2963M-C (8/10)
78
Download from Www.Somanuals.com. All Manuals Search And Download.
Users
Unicast
Multicast
Up to 20 simultaneous users depending on resolution settings (2 guaranteed streams)
Unlimited users H.264 or MPEG-4
Security Access
Password protected
Software Interface
Pelco System Integration
Open IP Integration
Web browser view and setup, up to 16 cameras
Endura 2.0 (or later), Digital Sentry 4.2 (or later)
Pelco IP camera API
ENVIRONMENTAL
Operational Temperature
14° to 122°F (–10° to 50°C)
20% to 80%, noncondensing
Operational Humidity
PHYSICAL
Dimensions
5.4" D x 3.1" W x 3.0" H
(13.7 x 7.9 x 7.6 cm)
Weight (without lens)
2.00 lb (0.90 kg)
79
C2963M-C (8/10)
Download from Www.Somanuals.com. All Manuals Search And Download.
C2963M-C (8/10)
80
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in
material or workmanship for a period of one year after the date of shipment.
• Six months:
All pan and tilts, scanners, or preset lenses used in continuous motion
applications (preset scan, tour, and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of
Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid
to a Pelco designated location. Repairs made necessary by reason of misuse,
alteration, normal wear, or accident are not covered under this warranty.
–
Exceptions to this warranty are as noted below:
• Five years:
–
–
–
Fiber optic products
Unshielded Twisted Pair (UTP) transmission products
CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and
MC3651H-2X camera models
Pelco assumes no risk and shall be subject to no liability for damages or loss
resulting from the specific use or application made of the Products. Pelco’s liability
for any claim, whether based on breach of contract, negligence, infringement of
any rights of any party or product liability, relating to the Products shall not exceed
the price paid by the Dealer to Pelco for such Products. In no event will Pelco be
liable for any special, incidental, or consequential damages (including loss of use,
loss of profit, and claims of third parties) however caused, whether by the
negligence of Pelco or otherwise.
• Three years:
–
Pelco-designed fixed network cameras and network dome cameras with
Sarix™ technology.
–
Pelco-branded fixed camera models (CCC1390H Series, C10DN Series,
C10CH Series, and IP3701H Series)
–
–
–
–
EH1500 Series enclosures
Spectra® IV products (including Spectra IV IP)
Camclosure® Series (IS, ICS, IP) integrated camera systems
The above warranty provides the Dealer with specific legal rights. The Dealer may
also have additional rights, which are subject to variation from state to state.
DX Series digital video recorders (except DX9000 Series which is covered
for a period of one year), DVR5100 Series digital video recorders, Digital
Sentry® Series hardware products, DVX Series digital video recorders, and
NVR300 Series network video recorders
Endura® Series distributed network-based video products
Genex® Series products (multiplexers, server, and keyboard)
PMCL200/300/400 Series LCD monitors
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the
following information:
–
–
–
–
1. Model and serial number
2. Date of shipment, P.O. number, sales order number, or Pelco invoice number
3. Details of the defect or problem
PMCL5xx Series FHD monitors
• Two years:
If there is a dispute regarding the warranty of a product that does not fall under
the warranty conditions stated above, please include a written explanation with
the product when returned.
–
–
–
–
Standard varifocal, fixed focal, and motorized zoom lenses
DF5/DF8 Series fixed dome products
Legacy® Series integrated positioning systems
Method of return shipment shall be the same or equal to the method by which the
item was received by Pelco.
Spectra III™, Spectra Mini, Spectra Mini IP, Esprit®, ExSite®, and PS20
scanners, including when used in continuous motion applications.
–
–
–
–
Esprit Ti and TI2500 Series thermal imaging products
Esprit and WW5700 Series window wiper (excluding wiper blades).
CM6700/CM6800/CM9700 Series matrix
RETURNS
To expedite parts returned for repair or credit, please call Pelco at (800) 289-9100
or (559) 292-1981 to obtain an authorization number (CA number if returned for
credit, and RA number if returned for repair) and designated return location.
Digital Light Processing (DLP®) displays (except lamp and color wheel). The
lamp and color wheel will be covered for a period of 90 days. The air filter is
not covered under warranty.
All merchandise returned for credit may be subject to a 20 percent restocking and
refurbishing charge.
–
Intelli-M® eIDC controllers
• One year:
Video cassette recorders (VCRs), except video heads. Video heads will be
covered for a period of six months.
Goods returned for repair or credit should be clearly identified with the assigned
CA or RA number and freight should be prepaid.
–
2-10-10
The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002/95/EC.
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union
regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.
REVISION HISTORY
Manual #
C2963M
C2963M-A
C2963M-B
C2963M-C
Date
10/09
1/10
3/10
8/10
Comments
Original version.
Added Sarix 1.4 software features to the operation section.
Added Sarix 1.5 software features to the operation section.
Added Sarix 1.6 software features to the operation section.
Pelco, the Pelco logo, and other trademarks associated with Pelco products referred to in this publication are trademarks of Pelco, Inc. or its affiliates.
All other product names and services are the property of their respective companies.
© Copyright 2010, Pelco, Inc.
All rights reserved.
Product specifications and availability are subject to change without notice.
Download from Www.Somanuals.com. All Manuals Search And Download.
Pelco, Inc. Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA
USA & Canada Tel (800) 289-9100 Fax (800) 289-9150
International Tel +1 (559) 292-1981 Fax +1 (559) 348-1120
Download from Www.Somanuals.com. All Manuals Search And Download.
|
Peavey Portable Speaker 1264 H User Manual
Philips Cable Box 32PFL66X6H User Manual
Philips Cassette Player DAT850 User Manual
Philips Cordless Telephone TU7372 User Manual
Philips Work Light ED 37 User Manual
Pioneer Stereo Amplifier PRS D400 User Manual
Planar Projector PD7170 User Manual
Planar Projector PR6020 User Manual
Polaris Offroad Vehicle 440 IQ User Manual
Poulan Lawn Mower 159699 User Manual