Pelco Security Camera C2423M User Manual

®
SD5BCBW Series  
Spectra II™  
Color/Black & White  
Dome Systems  
Operation and  
Programming Manual  
C2423M (5/00)  
In North America and Canada: Tel (800) 289-9100 • FAX (800) 289-9150  
International Customers: Tel +1(559) 292-1981 • FAX +1(559) 348-1120  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFEGUARDS AND WARNINGS  
Prior to installation and use of this product, the following WARNINGS should be observed.  
1. Installation and servicing should only be done by qualified service personnel and  
conform to all local codes.  
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P  
enclosure, it is designed for indoor use only and it must not be installed where  
exposed to rain and moisture.  
3. Only use replacement parts recommended by Pelco.  
4. After replacement/repair of this unit’s electrical components, conduct a resistance  
measurement between line and exposed parts to verify the exposed parts have not  
been connected to line circuitry.  
5. The installation method and materials should be capable of supporting four times the  
weight of the enclosure, pan/tilt, camera and lens combination.  
The product and/or manual may bear the following marks:  
This symbol indicates that dangerous voltage  
constituting a risk of electric shock is present  
within this unit.  
CAUTION:  
RISK OF ELECTRIC SHOCK.  
DO NOT OPEN.  
This symbol indicates that there are important  
operating and maintenance instructions in the  
literature accompanying this unit.  
Please thoroughly familiarize yourself with the information in this manual prior to installation  
and operation.  
MEASURES DE SECURITE IMPORTANTES  
Avant d’installer ou d’utiliser ce produit, les mesures de sécurité suivantes sont à prendre:  
1. Toute installation et réparation devraient être entreprises par un technicien qualifié et  
conformes au codes locaux.  
2. A moins que cet equipement indique avoir un boitié agrée NEMA de type 3, 3R, 3S, 4,  
4X, 6 ou 6P, il est uniquement conçu pour utilisation intérieure et ne peut donc pas  
être en contact de pluie ou d’humidité.  
3. Utiliser seulement les pièces de rechanges recommandées par Pelco.  
4. Après toute installation ou réparation de la partie électrique de ce produit, une  
résistance entre le courant et la partie exposée devrait être installée afin de vérifier  
que la partie électrique n’aie pas été en contact d’un court circuit.  
5. Linstallation entreprise et le matériel utilisé devraient supporter quatre fois le poids du  
boitié, de la tourelle, de la caméra, et de la lentille.  
Ce produit et/ou le manuel pourrait inclurent les symbols suivants:  
Ce symbol indique qu’un voltage  
dangereux pouvant provoquer un chock  
CAUTION:  
électrique est présant dans cette unité.  
RISQUE DE CHOQUE ÉLECTRIQUE.  
NE PAS OUVRIR.  
Ce symbol indique qu’il y a des mesures  
d’installation et d’entretient importantes  
inclus dans le manuel de cet équipement.  
Nous vous prions de bien vous familiarisez avec la manuel avant d’entreprendre toute in-  
stallation.  
Pelco Manual C2423M (5/00)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
POWER-UP DISPLAY  
When the Spectra II™ dome is powered up, the selected protocol, revision number, and  
other information is displayed on the monitor. For example, the screen might show the  
following information:  
The information displayed depends on the selected  
protocol (C, D, or P) and the menu selection for power-  
PELCO SPECT II 4.0  
up mode. (Refer to the Power-Up Mode in the  
CONFIGURE DONE  
Programming section).  
Protocol C  
The information remains on the monitor until the dome  
is moved.  
OPERATING YOUR SPECTRA II COLOR/BLACK & WHITE DOME  
Operation  
Pan and Tilt  
Scanning  
How to Control  
Move joystick left/right and up/down.  
Stop Scan  
Preset 96  
Preset 97  
Preset 98  
Preset 99  
Random Scan  
Frame Scan  
Auto Scan  
Zoom Far  
To zoom far, do the following:  
1. Press the Zoom Tele button or turn the joystick clockwise until you have the picture you want or you  
reach the optical zoom1 limit.  
2. Release the button or joystick.  
3. To continue zooming (digitally), immediately press the button or turn the joystick clockwise again until  
you have the picture you want or you reach the digital zoom2 limit.  
Zoom Wide  
Presets  
Patterns3  
Zones  
Press the Zoom Wide button or turn the joystick counterclockwise.  
Refer to the documentation supplied with the controller.  
Refer to the documentation supplied with the controller.  
Refer to the Programming section and to the documentation supplied with the controller.  
Refer to Alarms in the Operating Notes and in the Programming section.  
Turn on or off in the programming menu. Refer to the Programming Guide in the Programming section.  
Alarms  
Auto Flip  
1
Optical zoom magnifies the image and the picture remains clear. Resolution is constant.  
Digital zoom magnifies the image and the picture may appear pixilated. The larger the zoom limit the greater the reduction in  
resolution.  
2
3
The dome cannot do electronic zoom in a pattern. Optical zoom will operate in a pattern.  
For more information, refer to Operating Notes.  
4
Pelco Manual C2423M (5/00)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING NOTES  
PAN AND TILT FUNCTIONS  
Controller Type  
Fixed speed  
Variable speed  
Turbo Mode  
Pan  
Tilt  
Speed determined by controller  
0.1 to 80° per second, depending on joystick position  
150° per second  
Speed determined by controller  
0.1 to 40° per second, depending on joystick position  
200° per second  
Preset Mode  
250° per second  
Does not affect the tilt speed  
If the proportional pan mode is enabled (refer to Proportional Pan in the Programming  
section), the pan and tilt speeds will depend on the amount of zoom. At telephoto zoom  
settings, the pan and tilt speeds will be slower for a given amount of joystick deflection than  
at wide zoom settings. This keeps the image from moving too fast on the monitor when  
there is a large amount of zoom. This slowing does not happen when going to a preset, but  
does occur in turbo mode when high zoom is selected. The minimum pan and tilt speeds  
are 0.1 degree per second at full zoom.  
AUTO FLIP  
When the camera tilts downward and goes just beyond the vertical position, the dome  
rotates 180 degrees. When the dome rotates (flips), the camera starts moving upward as  
long as you continue to hold the joystick in the down position. Once you let go of the joystick  
after the dome rotates, joystick control returns to normal operation. The auto-flip feature is  
useful for following a person who passes directly beneath the camera. Refer to Auto Flip in  
the Programming section.  
SCAN SPEED  
Scan speed is adjustable from 1 to 40 degrees per second through the programming menu.  
PRESET FUNCTIONS  
The Spectra II dome is capable of going to 64 preset locations, each with a 20-character  
label. The presets are numbered 1-32 and 35-66. Refer to the documentation for your  
control system for programming presets.  
NOTE: For American  
Dynamics controllers with  
only 32 presets, set switch  
SW1-7 on the dome drive in  
the ON position. When  
SW1-7 is ON, preset  
When a preset operation is performed, the amount of error in moving to the pan and tilt  
position is 1/2 degree. If you command the dome to go to an undefined preset, erratic  
operation may result.  
Presets 33 and 34 are fixed commands, meaning that you cannot program them. Preset 33  
is the “flip” command, which will pan the dome drive 180 degrees. Preset 34 is the “pan zero”  
command, which will direct the dome drive to the factory-determined zero reference point.  
99 becomes 32  
98 becomes 31  
97 becomes 30  
96 becomes 29  
95 becomes 28  
93 becomes 26  
92 becomes 25  
91 becomes 24  
90 becomes 23  
89 becomes 22  
88 becomes 21  
RANDOM, FRAME, AND AUTO SCANNING  
Call preset 97 (30) to start random scanning. Call preset 98 (31) to activate frame scanning  
(three seconds of scanning followed by a three-second pause). Call preset 99 (32) to start  
auto (continuous) scanning. Scan limit stops are controlled by software. Refer to the Limit  
Stops section to program the scan limit stops. When the dome reaches a scan limit stop, it  
reverses direction. Call preset 96 (29) to stop a scan. Any pan/tilt or lens command also will  
stop a scan.  
ZONES  
If the limit stops are turned  
off (refer to the Limit Stops  
section), presets 23-26 can  
be used as regular presets.  
The Spectra II dome is capable of eight zones, each with a 20-character label. Depending  
on the controller, you can define the zone size and define any zone as “blanked” for video  
when the camera pans into the zone area. If zone labels are turned off, the system displays  
the message, VIDEO BLANK, to indicate the video is being blanked and is not failing.  
(Refer to Zone Blank in the Programming section for instructions.)  
Pelco Manual C2423M (5/00)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
PATTERNS  
The Spectra II dome can do either one full pattern (1.5, 3, or 6 minutes long) or two half  
patterns (.75, 1.5, or 3 minutes long). This pattern can consist of any standard pan and tilt  
or lens command. Presets, flip, and turbo are not allowed in a pattern. Zone scan can be  
enabled while running a pattern.  
NOTE: The dome cannot  
do electronic zoom in a  
pattern. Optical zoom will  
operate in a pattern.  
Refer to the documentation for your control system to program and run patterns.  
ALARMS  
The Spectra II dome has seven alarm inputs, which can be designated as either high or low  
priority through its programming menu.  
When an alarm is received, the dome does one of the following:  
Moves to the preset position that corresponds to the alarm number. For example, if  
alarm 3 is activated, the dome moves to preset 3.  
Runs a half pattern or full pattern as programmed in the Alarm Pattern menu.  
If the activated alarm inputs have the same priority–all low or all high–then the dome  
will sequence between the presets that correspond to the alarm numbers.  
If the activated alarm inputs have different priorities–for example, one is high and four  
are low–the dome goes only to the high. It remains fixed on the high and only goes to  
the low after the high has been cleared.  
In certain situations, the dome will respond as follows:  
If a preset has not been set, but an alarm is connected, the dome will go to a factory  
preset that will not be the desired position.  
If one alarm is a preset and another is a pattern and both are received, the dome will  
alternate between them.  
An alarm clears by returning to its former (off) state.  
Depending on choices made on the programming menu, the dome can respond to an alarm  
by running one of the patterns below. (Refer to Patterns in the Programming section for  
more information.)  
Run full pattern  
Run half pattern 1  
Run half pattern 2  
When sequencing between presets, the dwell time depends on the time set on the Alarm  
Dwell menu for that preset. After the dwell time expires, the dome immediately does one of  
the following:  
If the resume feature was selected on the programming menu and there are no other  
alarms activated, the dome resumes its prior activity. So, it might return to its previous  
position or resume a scan or pattern.  
If there are other alarms activated, the dome goes to them.  
If you move the joystick to pan or tilt the dome, or if you issue a lens command while there  
is an alarm, the pan and tilt or lens command overrides the alarm. Sixty seconds after the  
last pan and tilt or lens command, the dome will return to the alarm preset if the alarm is  
still active.  
6
Pelco Manual C2423M (5/00)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AUXILIARY OUTPUTS  
An AUX 1 command from the controller will activate the relay in the dome and operate the  
device that is connected to the relay. The relay will remain latched until a clear command is  
issued.  
An AUX 2 command from the controller will place a ground at the output of AUX 2 to  
operate the device that is connected to it. The output will remain latched until a clear  
command is issued.  
The output relay can also be programmed so that it is activated when any alarm input is  
activated. When latching (toggling) is selected on the programming menu, giving the AUX 1  
command from the controller changes the state of the AUX (for example, if it was on, this  
turns it off.) The clear command from the controller will turn the AUX off in the latching or  
toggle mode.  
PARK  
If the dome does not receive any commands for a specified period of time (refer to Park  
Time Minutes in the Programming section), the dome will go to preset 1 and park. If the  
time specified is zero, or if preset 1 has not been programmed, the dome will not park.  
The default is zero minutes.  
IR FILTER  
The Spectra II color/black and white dome has an IR (infrared) cut filter in the lens that  
switches in and out, automatically or manually, depending on how the dome is  
programmed. Automatic operation is controlled by the Auto IR Level setting. Manual  
operation is controlled by presets 88 (filter IN) and 89 (filter OUT).  
The dome also has two settings that enhance viewing in low light: the Auto IR Level and  
Slow Shutter Mode.  
The IR filter level is the light level at which the lens switches IN or OUT. When the filter is  
IN, the camera produces a color picture. When the IR filter switches OUT, the picture  
changes to black and white, increasing visibility in low light conditions.  
The slow shutter mode electronically extends the shutter time, providing greater sensitivity  
in low light conditions. The picture may appear rough or smeared, depending on the dis-  
tance and motion of the viewed image. This feature operates with the IR filter IN or OUT.  
LOW LIGHT does not mean NO LIGHT. Some type of illumination is required  
(street light, IR light, etc.). The camera is not sensitive to IR light when the IR cut  
filter is IN.  
AUTO IRIS  
If auto iris is in the auto mode, it remains that way until you manually open or close the iris.  
The dome will return to auto iris when it is panned or tilted more than 15 degrees. If there is  
not enough light for a good picture when the iris is wide open, you can increase the gain of  
the camera to improve the picture.  
To increase the gain:  
1. Hold down the Iris Open button until the iris is wide open.  
2. Release the button.  
3. Within one second, hold down the button again. This starts increasing the camera  
gain. Hold down the button until a desirable picture is obtained or the maximum gain is  
reached.  
Pelco Manual C2423M (5/00)  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROGRAMMING  
Programming Guide - Spectra II Color/Black & White  
Gain/AGC Menu  
1. Access main menu (preset 95).  
2. Make main menu selections.  
Joystick: Move up or down to position cursor or  
to toggle between selections.  
AGC mode  
Gain  
Auto  
6
Iris Open: Enter  
Camera Menu  
Iris Close: Cancel  
Exit  
Backlight comp  
Zoom limit  
Reset camera  
<Gain/AGC>  
<Auto-iris>  
<Next>  
Off  
x72  
Auto-Iris Menu  
IR Filter Menu  
Exit  
Auto-iris mode Auto  
IR Filter mode  
Auto IR Level  
Exit  
Auto  
Dusk  
Line Sync Menu  
Auto-iris level  
Exit  
7
MAIN MENU  
Line sync  
Line sync phase  
On  
0
<Camera>  
Next Menu  
Sharpness Menu  
<Line Sync>  
<Power Up>  
<Aux>  
<Alarms, Zone Blank>  
<Other>  
Exit  
Slow shutter mode Auto  
Shutter speed Auto  
Auto focus mode Auto  
<IR Filter>  
<Sharpness>  
<White balance>  
Previous  
Sharpness  
Exit  
15  
EXIT  
Power-Up Menu  
Exit  
Power Up  
Exit  
Default  
Alarm Priority Menu  
White Balance Menu  
PRESETS  
Alarm  
1
2
3
4
5
6
7
Low  
Low  
Low  
Low  
Low  
Low  
Low  
The following presets are  
reserved for special functions.  
Auto white bal  
Red bal level  
Blue bal level  
Exit  
On  
- -  
- -  
Preset  
1
1-7  
33  
34  
Function  
Park  
Alarms, if used  
Flip command  
Pan zero  
Aux Menu  
Exit  
command  
IR filter IN  
Aux 1 mode  
Aux 2 mode  
Exit  
Normal  
Normal  
88  
89  
Alarm Pattern Menu  
IR filter OUT  
Manual limit stops  
Scan limit stops  
Select camera  
programming  
menu  
90-91  
92-93  
95  
Alarm  
1No Pattern  
2No Pattern  
3No Pattern  
4No Pattern  
5No Pattern  
6No Pattern  
7No Pattern  
Alarms, Zone Blank Menu  
96  
97  
98  
99  
Stop a scan  
Random scanning  
Frame scanning  
Start auto  
Alarm resume  
Alarm dwell sec  
<Alarm priority>  
<Alarm pattern>  
<Zone blank>  
Exit  
Off  
5
Exit  
scanning  
Zone Blank Menu  
Video Blank Zone 1Off  
2Off  
3Off  
4Off  
5Off  
Other Menu  
6Off  
7Off  
8Off  
Auto flip  
Proportional pan  
Limit stops  
On  
On  
Off  
0
Exit  
Park time minutes  
Scan speed deg/s 25  
Pattern length 1.5 min  
Exit  
For detailed instructions, refer to the following sections.  
Menu items are listed alphabetically.  
8
Pelco Manual C2423M (5/00)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSING MAIN MENU (PRESET 95)  
You can call up the main menu on your monitor by programming (setting or creating) preset  
95 (28 if in 32-preset mode).  
NOTE: For American  
Dynamics controllers with  
only 32 presets, set switch  
SW1-7 on the dome drive in  
the ON position. When  
SW1-7 is ON, preset  
Programming preset 95 for Pelco’s controllers varies according to the type of controller you  
are using. Instructions for programming preset 95 are given below for various Pelco  
controllers.  
CM6700  
99 becomes 32  
98 becomes 31  
97 becomes 30  
96 becomes 29  
95 becomes 28  
93 becomes 26  
92 becomes 25  
91 becomes 24  
90 becomes 23  
89 becomes 22  
88 becomes 21  
1. Enter the number of the Spectra II or Spectra Lite camera and press the CAM key.  
2. Enter 95 and hold the PRESET key for two seconds.  
3. In the Edit Preset menu, arrow to SET and press the ACK key. The main menu appears.  
KBD200/KBD300/KBD300V (Direct Mode Only)  
1. Enter 95.  
2. Hold the PRESET key (approximately 5 seconds) until the main menu appears on the  
screen.  
CM8500  
1. Enter the number of the Spectra II or Spectra Lite camera and press the CAM key.  
2. Highlight PRESET in the Camera menu and hold down the joystick button until the Set  
Presets prompt appears.  
3. Enter 95 and press the PRESET key. The text editor appears. Select ENTER and the  
main menu appears.  
If the limit stops are turned  
off (refer to the Limit Stops  
section), presets 23-26 can  
be used as regular presets.  
CM9500  
1. Enter the number of the Spectra II or Spectra Lite camera and press the CAM key.  
The Main menu appears.  
2. Highlight SETUP in the Main menu and press the SELECT key.  
3. Highlight CAM in the Setup menu and press the SELECT key.  
4. Highlight PRESET in the Camera menu and press the SELECT key.  
5. Enter 95 and press the F1 key. The main menu appears.  
CM9750  
1. Turn the KEY SWITCH to the ON position.  
2. Press the PROG key. PROGRAM appears on the LCD display.  
3. Press the PRES key. The PRESET prompt appears.  
4. Enter 95 and press the ENTER key. The main menu appears.  
5. Turn the KEY SWITCH to the OFF position.  
CM9760  
1. Press the ESCAPE key to open the Main menu. Select DEF. The Define Menu appears.  
2. Enter your four-digit PIN if this is your first time entering this mode.  
3. Enter 95 and select PRST. The main menu appears on the monitor.  
4. Select the Quit icon to return to the default menu.  
KBD4000/KBD4002/KBD4000V  
1. Press the SPOT MONITOR key.  
2. Enter 95, then hold the PRESET key (approximately five seconds) until the main menu  
appears on the screen.  
MPT9500  
Standard Coaxitron Mode  
1. Enter 95 and press the PRESET SET key.  
2. Position the asterisk in the YES row and press the F1 key. The main menu appears.  
Extended Coaxitron or RS-485 Mode  
1. Enter 95 and press the PRESET SET key.  
2. Press the F2 key. The main menu appears.  
Pelco Manual C2423M (5/00)  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
ALARMS  
The Spectra II dome has seven alarm inputs, which can be designated as either high or low  
priority.The high priority setting is significant when more than one alarm is activated. If priority in  
alarms is not required, leave all alarms in the low setting. Refer to the Alarm Priority section.  
If presets 1-7 are not used for alarms, they can be used as regular presets. However, if they  
are being used for alarms, they should not be used for anything else.  
Also refer to the Alarm Dwell, Alarm Pattern, Alarm Resume, and Pattern Length sections  
to program alarm conditions.  
ALARM DWELL  
Main Menu  
Alarms, Zone Blank Menu  
<Camera>  
Alarm resume  
Alarm dwell sec  
<Alarm priority>  
<Alarm pattern>  
<Zone blank>  
Exit  
Off  
5
<Line Sync>  
<Power Up>  
<Aux>  
<Alarms, Zone Blank>  
<Other>  
EXIT  
This is the minimum time the Spectra II will stay at an alarm even if the alarm is present for  
less than this amount of time.  
To change the alarm dwell:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Alarms, Zone Blank.  
3. Press the Iris Open button to enter the Alarms, Zone Blank menu.  
4. Position the cursor (>) beside Alarm Dwell Sec.  
5. Press the Iris Open button. The cursor moves to the right, beside the number of  
seconds for the alarm dwell time.  
6. Move the joystick up or down and hold to cycle through 1-200 seconds in one-second  
increments.  
7. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
ALARM PATTERN  
Main Menu  
Alarms, Zone Blank Menu  
Alarm Pattern Menu  
Alarm  
1No Pattern  
2No Pattern  
3No Pattern  
4No Pattern  
5No Pattern  
6No Pattern  
7No Pattern  
<Camera>  
<Line Sync>  
<Power Up>  
<Aux>  
<Alarms, Zone Blank>  
<Other>  
Alarm resume  
Alarm dwell sec  
<Alarm priority>  
<Alarm pattern>  
<Zone blank>  
Exit  
Off  
5
EXIT  
Exit  
NOTE: Pattern length is set  
on the secondary menu  
entitled Other.  
You can choose one of the following for each of the seven alarm inputs:  
Full Pat (run full pattern)  
Half Pat 2 (run half pattern 2)  
No Pattern  
Half Pat 1 (run half pattern 1)  
NOTE: To make the pattern  
run to its end when an alarm  
activates it, make alarm  
dwell time longer than  
In response to an alarm, the Spectra II dome can do either one full pattern (1.5, 3, or 6  
minutes long) or two half patterns (.75, 1.5, or 3 minutes long).  
To change the alarm pattern:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Alarms, Zone Blank.  
3. Press the Iris Open button to enter the Alarms, Zone Blank menu.  
4. Position the cursor (>) beside Alarm Pattern.  
5. Press the Iris Open button to enter the Alarm Pattern menu.  
pattern length. Thus, if the  
alarm goes away before the  
end of the pattern, the  
pattern will continue until the  
dwell times out.  
10  
Pelco Manual C2423M (5/00)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Position the cursor (>) beside the number of the alarm input for which you want to set  
the pattern.  
7. Press the Iris Open button. The cursor moves to the right, beside the words Full Pat,  
Half Pat 1, Half Pat 2, or No Pattern.  
8. Move the joystick up or down to toggle between the choices.  
9. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
NOTE: The Spectra II  
Color/Black and White  
camera cannot do electronic  
zoom in a pattern. Optical  
zoom will operate in a  
pattern.  
ALARM PRIORITY  
Alarms, Zone Blank Menu  
Alarm Priority Menu  
Main Menu  
Alarm  
1
2
3
4
5
6
7
Low  
<Camera>  
<Line Sync>  
<Power Up>  
<Aux>  
<Alarms, Zone Blank>  
<Other>  
EXIT  
Alarm resume  
Alarm dwell sec  
<Alarm priority>  
<Alarm pattern>  
<Zone blank>  
Exit  
Off  
5
Low  
Low  
Low  
Low  
Low  
Low  
Exit  
This feature lets you set alarm priority inputs as one of the following:  
High - A high priority alarm will not release to a low priority alarm.  
Low - Alarms will release or sequence between low priority alarms only if no high  
priority alarm exists.  
To change alarm priority:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Alarms, Zone Blank.  
3. Press the Iris Open button to enter the Alarms, Zone Blank menu.  
4. Position the cursor (>) beside Alarm Priority.  
5. Press the Iris Open button to enter the Alarm Priority menu.  
6. Position the cursor (>) beside the number of the alarm input for which you want to set  
the priority.  
7. Press the Iris Open button. The cursor moves to the right, beside the word High or Low.  
8. Move the joystick up or down to toggle between the words High and Low.  
9. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
ALARM RESUME  
Main Menu  
Alarms, Zone Blank Menu  
<Camera>  
Alarm resume  
Alarm dwell sec  
<Alarm priority>  
<Alarm pattern>  
<Zone blank>  
Exit  
Off  
5
<Line Sync>  
<Power Up>  
<Aux>  
<Alarms, Zone Blank>  
<Other>  
EXIT  
This mode lets the dome resume its previous activity (scan, pattern, or previous position)  
after all alarms are cleared.  
There are two alarm resume modes:  
On - Alarm resume mode is enabled.  
Off - Alarm resume mode is disabled.  
To change the alarm resume mode:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Alarms, Zone Blank.  
3. Press the Iris Open button to enter the Alarms, Zone Blank menu.  
4. Position the cursor (>) beside Alarm Resume.  
5. Press the Iris Open button. The cursor moves to the right, beside the word On or Off.  
6. Move the joystick up or down to toggle between On or Off.  
7. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
Pelco Manual C2423M (5/00)  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AUTO FLIP  
Main Menu  
Other Menu  
<Camera>  
Auto flip  
Proportional pan  
Limit stops  
On  
On  
Off  
0
<Line Sync>  
<Power Up>  
<Aux>  
Park time minutes  
<Alarms, Zone Blank>  
<Other>  
EXIT  
Scan speed deg/s 25  
Pattern length 1.5 min  
Exit  
There are two auto flip modes:  
On - Auto flip mode is enabled.  
Off - Auto flip mode is disabled.  
To change the auto flip mode:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Other.  
3. Press the Iris Open button to enter the Other menu.  
4. Position the cursor (>) beside Auto Flip.  
5. Press the Iris Open button. The cursor moves to the right, beside the word On or Off.  
6. Move the joystick up or down to toggle between On and Off.  
7. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
AUTO FOCUS MODE  
Main Menu  
Camera Menu  
Next Menu  
<Camera>  
<Line Sync>  
<Power Up>  
<Aux>  
<Alarms, Zone Blank>  
<Other>  
Backlight comp  
Zoom limit  
Reset camera  
<Gain/AGC>  
<Auto-iris>  
<Next>  
Off  
x72  
Slow shutter mode Auto  
Shutter speed  
Auto  
Auto focus mode Auto  
<Sharpness>  
<White balance>  
Previous  
EXIT  
Exit  
Exit  
There are two auto focus modes:  
Auto - If auto focus is in the auto mode, pressing the Focus Far or Focus Near button  
will place the focus in the manual mode. The dome will return to auto focus if  
you pan or tilt the unit or do a zoom function.  
Off - If the mode is set to off, the dome will operate in the manual mode with one  
exception. If you issue a command to go to a preset, auto focus will turn on and  
remain on until you press the Focus Far or Focus Near button.  
To change the mode:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Camera.  
3. Press the Iris Open button to enter the Camera menu.  
4. Position the cursor (>) beside Next.  
5. Press the Iris Open button to go to the Next menu.  
6. Position the cursor (>) beside Auto Focus Mode.  
7. Press the Iris Open button. The cursor moves to the right, beside the word Auto or Off.  
8. Move the joystick up or down to toggle between Auto and Off.  
9. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
NOTE: Auto focus is auto-  
matically turned off when  
the shutter time is longer  
than 1/8 of a second.  
12  
Pelco Manual C2423M (5/00)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AUTO IRIS  
Main Menu  
Camera Menu  
Auto-Iris Menu  
<Camera>  
Backlight comp  
Zoom limit  
Reset camera  
<Gain/AGC>  
<Auto-iris>  
<Next>  
Off  
x72  
<Line Sync>  
<Power Up>  
<Aux>  
<Alarms, Zone Blank>  
<Other>  
Auto-iris mode  
Auto-iris level  
Exit  
Auto  
7
EXIT  
Exit  
The following are the settings for auto iris:  
Mode  
Level  
To change the settings for auto iris:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Camera.  
3. Press the Iris Open button to enter the Camera menu.  
4. Position the cursor (>) beside Auto-Iris.  
5. Press the Iris Open button. The Auto Iris menu appears.  
6. Position the cursor (>) and select one of the following settings:  
MODE - The cursor moves to one of two choices:  
Auto - The iris is automatically adjusted to produce a constant video output as deter-  
mined by the Level setting.  
Off - Auto iris is disabled, and control is always manual.  
Move the joystick up or down to toggle between Auto and Off. Press the Iris Open  
button to select the choice, or press the Iris Close button if you do not want to change  
the setting.  
LEVEL - The cursor moves to a numeric value, which the dome uses to try to  
maintain a certain light level. Changing the value of the Level setting will change the  
video level to which the auto iris adjusts. This setting should be adjusted if the video  
level in the auto iris mode is too bright or too dark. Move the joystick up or down to a  
value. Press the Iris Open button to select the value, or press the Iris Close button if  
you do not want to change the setting.  
Pelco Manual C2423M (5/00)  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AUTO IR LEVEL  
Main Menu  
Camera Menu  
Next Menu  
IR Filter Menu  
Slow shutter mode  
Shutter speed  
Auto focus mode  
<IR Filter>  
<Sharpness>  
<White balance>  
Previous  
Auto  
Auto  
Auto  
<Camera>  
<Line Sync>  
<Power Up>  
<Aux>  
<Alarms, Zone Blank>  
<Other>  
Backlight comp  
Off  
x72  
Zoom limit  
Reset camera  
<Gain/AGC>  
<Auto-iris>  
<Next>  
IR Filter mode  
Auto IR Level  
Exit  
Auto  
Dusk  
EXIT  
Exit  
Exit  
The IR level setting determines when the IR filter will switch IN or OUT. Following are the  
available settings for the Auto IR Level:  
Dusk = 1/60 second shutter speed  
2 =  
3 =  
1/60 second shutter speed  
1/30 second shutter speed  
Dark = 1/15 second shutter speed  
Slow shutter operation affects the auto IR level setting.  
If slow shutter is set for manual operation, only two settings for the IR level are available:  
Dusk and 2.  
If slow shutter is set for automatic operation, all four IR level settings are available.  
If the IR level is set at 3 or Dark and the slow shutter is turned off, the IR level will auto-  
matically reset to 2.  
To program the slow shutter mode, refer to the Slow Shutter Mode section.  
To change the auto lR level settings:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Camera.  
3. Press the Iris Open button to enter the Camera menu.  
4. Position the cursor (>) beside Next.  
5. Press the Iris Open button to enter the Next menu.  
6. Position the cursor (>) beside IR Filter.  
7. Press the Iris Open button to enter the IR Filter menu.  
8. Position the cursor (>) beside Auto IR level.  
9. Press the Iris Open button. The cursor moves to the right.  
10. Move the joystick up or down to toggle between the four level settings.  
11. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
AUX MODE  
Main Menu  
Aux Menu  
<Camera>  
<Line Sync>  
<Power Up>  
<Aux>  
<Alarms, Zone Blank>  
<Other>  
Aux 1 mode  
Aux 2 mode  
Exit  
Normal  
Normal  
EXIT  
There are three settings for AUX mode:  
Normal - Controller operated.  
Latching - Pressing the AUX key turns on the AUX and the next press of the AUX key  
turns it off.  
Alarm - Any alarm input activates the AUX.  
Refer to your controller manual for operating instructions.  
To change the AUX mode:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside AUX.  
3. Press the Iris Open button to enter the AUX menu.  
14  
Pelco Manual C2423M (5/00)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.  
Move the joystick up or down to position the cursor next to either Aux 1 mode or Aux 2  
mode.  
5. Press the Iris Open button. The cursor moves to the right, beside the word Normal,  
Latching, or Alarm.  
6. Move the joystick up or down to toggle between Normal, Latching, or Alarm.  
7. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
BACKLIGHT COMPENSATION  
Main Menu  
Camera Menu  
<Camera>  
Backlight comp  
Zoom limit  
Reset camera  
<Gain/AGC>  
<Auto-iris>  
<Next>  
Off  
x72  
<Line Sync>  
<Power Up>  
<Aux>  
<Alarms, Zone Blank>  
<Other>  
EXIT  
Exit  
There are two backlight compensation modes:  
NOTE: If backlight  
On - The dome uses the center 10 percent of the picture to adjust the iris. If there is a  
bright light source outside of this area, it will wash out to white. The camera will  
adjust the iris so that the object in the sensitive area is properly exposed.  
Off - Backlight compensation is not activated.  
compensation is ON and the  
IR cut filter switches OUT  
(black and white mode) in  
normal lighting condi-  
tions, adjust the Auto IR  
Level to a darker setting.  
Refer to the Auto IR Level  
section.  
To change the backlight compensation mode:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Camera.  
NON-SENSITIVE AREA  
3. Press the Iris Open button to enter the Camera  
SENSITIVE  
menu.  
AREA  
4. Position the cursor (>) beside Backlight Comp.  
5. Press the Iris Open button. The cursor moves to  
the right, beside the word On or Off.  
6. Move the joystick up or down to toggle between On  
and Off.  
7.  
SELECT - Press the Iris Open button on your  
keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
Pelco Manual C2423M (5/00)  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GAIN/AGC  
Main Menu  
Camera Menu  
Gain/AGC Menu  
<Camera>  
Backlight comp  
Zoom limit  
Reset camera  
<Gain/AGC>  
<Auto-iris>  
<Next>  
Off  
x72  
<Line Sync>  
<Power Up>  
<Aux>  
<Alarms, Zone Blank>  
<Other>  
AGC mode  
Gain  
Exit  
Auto  
6
EXIT  
Exit  
Gain - The amount of amplification the camera places on its video information in order to  
obtain a full 1-volt peak-to-peak video signal out.  
AGC - Automatic Gain Control.  
AGC MODE  
There are two AGC settings :  
Auto Mode - Automatically adjusts the gain.  
Off Mode - In the off mode the AGC is off.  
To change the AGC mode:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Camera.  
3. Press the Iris Open button to enter the Camera menu.  
4. Position the cursor (>) beside Gain/AGC.  
5. Press the Iris Open button to enter the Gain/AGC menu.  
6. Position the cursor (>) beside AGC mode.  
7. Press the Iris Open button. The cursor moves to the right, beside the word Auto or Off.  
8. Move the joystick up or down to choose between Auto or Off.  
9. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
GAIN  
The gain adjusts the signal level of the video output. Increasing the gain in low light condi-  
tions will increase the level of noise in the picture.  
To change the gain:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Camera.  
3. Press the Iris Open button to enter the Camera menu.  
4. Position the cursor (>) beside Gain/AGC.  
5. Press the Iris Open button to enter the Gain/AGC menu.  
6. Position the cursor (>) beside Gain.  
7. Press the Iris Open button. The cursor moves to the right, beside the current gain  
setting (a numeric value).  
8. Move the joystick up or down to change the gain. As you change the gain, the picture  
on your monitor gets brighter or darker.  
9. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
16  
Pelco Manual C2423M (5/00)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IR FILTER MODE  
Main Menu  
Camera Menu  
Next Menu  
IR Filter Menu  
Slow shutter mode  
Shutter speed  
Auto focus mode  
<IR Filter>  
<Sharpness>  
<White balance>  
Previous  
Auto  
Auto  
Auto  
<Camera>  
<Line Sync>  
<Power Up>  
<Aux>  
<Alarms, Zone Blank>  
<Other>  
Backlight comp  
Off  
x72  
Zoom limit  
Reset camera  
<Gain/AGC>  
<Auto-iris>  
<Next>  
IR Filter mode  
Auto IR Level  
Exit  
Auto  
Dusk  
EXIT  
Exit  
Exit  
There are two settings for the IR filter mode:  
Auto - IR filter switches in and out automatically. Do the following to setup the IR filter  
for automatic operation:  
CAMERA SETTING  
IR Filter  
SETUP  
Auto  
AGC mode  
Auto  
Shutter Speed  
Auto  
IMPORTANT: The AGC mode and shutter speed must be set to Auto for the IR  
filter to operate automatically. If the AGC mode or shutter speed is changed to  
a manual setting, the IR filter setting automatically switches to OFF.  
Off - IR filter is manually operated. The following presets are used to manually  
operate the IR filter:  
Preset 88 (21) - Filter IN (color)  
Preset 89 (22) - Filter OUT (black & white)  
To change the lR filter mode:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Camera.  
3. Press the Iris Open button to enter the Camera menu.  
4. Position the cursor (>) beside Next.  
5. Press the Iris Open button to enter the Next menu.  
6. Position the cursor (>) beside IR Filter.  
7. Press the Iris Open button to enter the IR Filter menu.  
8. Position the cursor (>) beside IR Filter mode.  
9. Press the Iris Open button. The cursor moves to the right, beside the word Auto or Off.  
10. Move the joystick up or down to toggle between Auto and Off.  
11. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
If the IR filter is set to Auto, check the AGC mode and shutter speed settings.  
Both must be programmed for automatic operation for the IR filter to function automati-  
cally. Refer to the Gain/AGC and Shutter Speed sections for programming information.  
LIMIT STOPS  
Main Menu  
Other Menu  
<Camera>  
Auto flip  
Proportional pan  
Limit stops  
On  
On  
Off  
0
<Line Sync>  
<Power Up>  
<Aux>  
Park time minutes  
<Alarms, Zone Blank>  
<Other>  
EXIT  
Scan speed deg/s 25  
Pattern length 1.5 min  
Exit  
There are two types of limit stops:  
Manual limit stops - A manual (joystick) pan operation stops when a limit stop is reached.  
Scan limit stops - The dome reverses direction during random, frame, or auto  
scanning when a limit stop is reached.  
Limit stops are controlled by software. To set limit stops:  
1. Turn on the limit stop mode.  
2. Program the limit stops.  
Pelco Manual C2423M (5/00)  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TURNING LIMIT STOPS ON OR OFF  
To change the limit stop mode:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Other.  
3. Press the Iris Open button to enter the Other menu.  
4. Position the cursor (>) beside Limit Stops.  
5. Press the Iris Open button. The cursor moves to the right, beside the word On or Off.  
6. Move the joystick up or down to toggle between On and Off.  
7. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
PROGRAMMING LIMIT STOPS  
Manual Limit Stops  
Refer to the documentation for your control system for programming presets, and then do  
the following:  
1. Make sure limit stops are turned ON, and then exit the menu.  
2. Push the joystick left until you reach the limit you want the camera to go to on the left.  
3. Program preset 90 (23).  
NOTE: Programming  
preset 90 (23) disables the  
manual limit stops until  
preset 91 (24) is set.  
4. Push the joystick right to the limit you want the camera to go to on the right.  
5. Program preset 91 (24).  
Setting presets 90 (23) and 91 (24) to the same point disables manual limit stops.  
Scan Limit Stops  
Refer to the documentation for your control system for programming presets, and then do  
the following:  
1. Make sure limit stops are turned ON, and then exit the menu.  
2. Push the joystick left until you reach the limit you want the camera to go to on the left.  
3. Program preset 92 (25).  
NOTE: On power-up, the  
auto scan tilt angle will be  
whatever angle the camera  
was at when the right scan  
limit was set.  
4. Push the joystick right to the limit you want the camera to go to on the right.  
5. Program preset 93 (26).  
Setting presets 92 (25) and 93 (26) to the same point disables scan limit stops.  
LINE SYNCHRONIZATION  
Main Menu  
Line Sync Menu  
<Camera>  
<Line Sync>  
<Power Up>  
<Aux>  
<Alarms, Zone Blank>  
<Other>  
Line sync  
Line sync phase  
Exit  
On  
0
EXIT  
If cameras are out of phase with each other, they may produce what appears to be vertical roll  
when switching between cameras.  
There are two settings for line synchronization:  
On - Adjust the synchronization of the power line voltage so that it is in phase with other  
cameras.  
Off - The dome synchronizes to an internal clock.  
To change the line synchronization settings:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Line Sync.  
3. Press the Iris Open button. The Line Sync menu appears.  
4. Position the cursor (>) beside one of the choices. Press the Iris Open button.  
LINE SYNC - The cursor moves to one of two choices: ON or OFF. Move the joystick up or  
down to toggle between them. Press the Iris Open button to select the choice. If you changed to  
OFF, the camera may reset itself as it adjusts to the new synchronization. If the camera resets,  
it will only affect the line synchronization. It will not change any other camera parameters, such  
as auto focus or auto iris. Press the Iris Close button if you do not want to change the setting.  
18  
Pelco Manual C2423M (5/00)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LINE SYNC PHASE - The cursor moves to a numeric value. Move the joystick up or down  
to change the value. Press the Iris Open button to select the choice. The value represents the  
phase angle in tenths of a degree between 0 degrees and 359 degrees. For example, 900 is  
90 degrees, 1200 is 120 degrees, and 2400 is 240 degrees. Press the Iris Open button on  
your keyboard to select your choice. The Line Sync setting will change to ON. The camera  
may reset or the picture on your monitor may wiggle when you change the phase angle. If the  
camera resets, it will only affect the line synchronization. It will not change any other camera  
parameters, such as auto focus or auto iris. Press the Iris Close button if you do not want to  
change the setting.  
PARK TIME MINUTES  
Main Menu  
Other Menu  
<Camera>  
Auto flip  
Proportional pan  
Limit stops  
On  
On  
Off  
0
<Line Sync>  
<Power Up>  
<Aux>  
Park time minutes  
<Alarms, Zone Blank>  
<Other>  
EXIT  
Scan speed deg/s 25  
Pattern length 1.5 min  
Exit  
This feature causes the dome to park at preset 1 after a programmed number of minutes of  
control inactivity. The time can be set from 1 minute to 720 minutes (12 hours), or it can be set  
to zero, which disables this feature.  
To change the park time:  
1. Program preset 95 (28). The main menu appears.  
2.  
Position the cursor (>) beside Other.  
3. Press the Iris Open button to enter the Other menu.  
4. Position the cursor (>) beside Park Time Minutes.  
5. Press the Iris Open button. The cursor moves to the right, beside the current park time.  
6. Move the joystick up or down to change the park time.  
7. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
NOTE: Preset 1 must be  
programmed for the dome to  
park.  
PATTERN LENGTH  
Main Menu  
Other Menu  
<Camera>  
Auto flip  
Proportional pan  
Limit stops  
On  
On  
Off  
0
<Line Sync>  
<Power Up>  
<Aux>  
Park time minutes  
<Alarms, Zone Blank>  
<Other>  
EXIT  
Scan speed deg/s 25  
Pattern length 1.5 min  
Exit  
The Spectra II dome can do the following:  
One full pattern - 1.5, 3, or 6 minutes long.  
or  
Two half patterns - .75, 1.5, or 3 minutes long.  
This pattern can consist of any standard pan and tilt or lens command. Presets, flip, and  
turbo are not allowed in a pattern. Zone scan can be enabled while running a pattern.  
To set the pattern length:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Other.  
3. Press the Iris Open button to enter the menu entitled Other.  
4. Position the cursor (>) beside Pattern Length.  
5. Press the Iris Open button. The cursor moves to the right, beside the number of  
minutes (1.5, 3, or 6).  
6. Move the joystick up or down to toggle through the number of minutes (1.5, 3, or 6).  
7. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
CAUTION: If the  
length is changed,  
all patterns that  
were stored are erased.  
Pelco Manual C2423M (5/00)  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
POWER-UP MODE  
Main Menu  
Power-Up Menu  
<Camera>  
<Line Sync>  
<Power Up>  
<Aux>  
Power Up  
Exit  
Default  
<Alarms, Zone Blank>  
<Other>  
EXIT  
This feature lets the dome resume a desired condition following power-up. The menu  
includes the following choices.  
Default -  
On power-up, the dome goes through a configuration cycle and stops at  
zero reference, showing “Configuration Done,address, and mode  
settings on the screen.  
Park -  
The dome moves to preset 1 when the power-up sequence finishes.  
The only text on the screen is the preset label (if any is programmed).  
Scan Auto - The dome initiates scan mode when the power-up sequence finishes.  
Again, there is no text.  
Scan Frame - The dome initiates a frame scan when the power-up sequence finishes.  
Scan Rand - The dome initiates a random scan when the power-up sequence finishes.  
Full Pat -  
The dome initiates its programmed pattern when the power-up sequence  
finishes. The length can be set to 1.5, 3, or 6 minutes.  
Half Pat 1 - The dome initiates the first half-pattern when the power-up sequence  
finishes. The length can be set to .75, 1.5, or 3 minutes.  
Half Pat 2 - The dome initiates the second half-pattern when the power-up sequence  
finishes. The length can be set to .75, 1.5, or 3 minutes.  
The default setting is Default.  
To select the power-up mode:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Power Up Mode.  
3. Press the Iris Open button to enter the Power Up Mode menu.  
4. Press the Iris Open button to move the cursor to the right.  
5. Move the joystick up or down to cycle through the selections. Stop on the item you  
want to select.  
6. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
PROPORTIONAL PAN  
Main Menu  
Other Menu  
<Camera>  
Auto flip  
Proportional pan  
Limit stops  
On  
On  
Off  
0
<Line Sync>  
<Power Up>  
<Aux>  
Park time minutes  
<Alarms, Zone Blank>  
<Other>  
EXIT  
Scan speed deg/s 25  
Pattern length 1.5 min  
Exit  
There are two proportional pan modes:  
On - Enables the proportional pan mode. The amount of zoom controls the pan and  
tilt. At telephoto zoom settings, the pan and tilt speeds will be slower for a given  
amount of joystick deflection than at wide zoom settings. This keeps the image  
from moving too fast on the monitor when there is a large amount of zoom.  
Off - Disables proportional pan mode. The pan speed will not depend on the amount  
of zoom.  
To change the proportional pan mode:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Other.  
20  
Pelco Manual C2423M (5/00)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Press the Iris Open button to enter the Other menu.  
4. Position the cursor (>) beside Proportional Pan.  
5. Press the Iris Open button. The cursor moves to the right, beside the word On or Off.  
6. Move the joystick up or down to toggle between On and Off.  
7. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
RESET CAMERA  
Main Menu  
Camera Menu  
<Camera>  
Backlight comp  
Zoom limit  
Reset camera  
<Gain/AGC>  
<Auto-iris>  
<Next>  
Off  
x72  
<Line Sync>  
<Power Up>  
<Aux>  
<Alarms, Zone Blank>  
<Other>  
EXIT  
Exit  
Resetting the camera returns the settings to their defaults.  
Default Settings  
Backlight comp  
Off  
Zoom limit  
Gain/AGC  
AGC mode  
Gain  
X72  
Auto  
6
Auto-iris  
Mode  
Level  
Auto  
7
Slow shutter mode  
Auto  
Shutter speed  
Auto focus mode  
IR Filter  
Auto  
Auto  
IR filter mode  
Auto IR level  
Sharpness  
Auto  
Dusk  
15  
White balance  
Auto white bal  
On  
Red bal level  
Blue bal level  
No default  
No default  
When the camera is reset, the following settings are not changed: park time, auto flip  
disable, limit stops, zoom limit, and proportional panning.  
Turning off power to the Spectra II dome does not reset the camera. Camera settings are  
retained in memory. When the power is turned back on, the settings will be the same as  
they were when the power was turned off.  
To reset the camera:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Camera.  
3. Press the Iris Open button to enter the Camera menu.  
4. Position the cursor (>) beside Reset Camera.  
5. Press the Iris Open button to reset the camera.  
Pelco Manual C2423M (5/00)  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCAN SPEED  
Main Menu  
Other Menu  
<Camera>  
Auto flip  
Proportional pan  
Limit stops  
On  
On  
Off  
0
<Line Sync>  
<Power Up>  
<Aux>  
Park time minutes  
<Alarms, Zone Blank>  
<Other>  
EXIT  
Scan speed deg/s 25  
Pattern length 1.5 min  
Exit  
The scan speed is adjustable from 1-40 degrees per second. This occurs in three scan  
modes: auto, random, and frame scan.  
To change the scan speed:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Other.  
3. Press the Iris Open button to enter the Other menu.  
4. Position the cursor (>) beside Scan Speed deg/s.  
5. Press the Iris Open button. The cursor moves to the right, beside the number of degrees.  
6. Move the joystick up or down to toggle through the number of degrees (1-40) until you  
reach the number you want. (If set on a low number, the scan will appear to barely  
move but is still functioning.)  
7. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
SHARPNESS  
Main Menu  
Camera Menu  
Next Menu  
Sharpness Menu  
Slow shutter mode  
Shutter speed  
Auto focus mode  
<IR Filter>  
<Sharpness>  
<White balance>  
Previous  
Auto  
Auto  
Auto  
<Camera>  
<Line Sync>  
<Power Up>  
<Aux>  
<Alarms, Zone Blank>  
<Other>  
Backlight comp  
Off  
x72  
Zoom limit  
Reset camera  
<Gain/AGC>  
<Auto-iris>  
<Next>  
Sharpness  
Exit  
15  
EXIT  
Exit  
Exit  
Do the following to manually adjust the sharpness of the picture:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Camera.  
3. Press the Iris Open button to enter the Camera menu.  
4. Position the cursor (>) beside Next.  
5. Press the Iris Open button to go to the Next menu.  
6. Position the cursor (>) beside Sharpness.  
7. Press the Iris Open button. The Sharpness menu opens.  
8. Press the Iris Open button. The cursor moves to the right, beside the sharpness value.  
9. Move the joystick up or down to toggle through available sharpness values. As the  
numeric value changes, the sharpness of the picture on the monitor changes.  
10. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
22  
Pelco Manual C2423M (5/00)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SHUTTER SPEED  
Main Menu  
Camera Menu  
Next Menu  
Slow shutter mode Auto  
<Camera>  
<Line Sync>  
<Power Up>  
<Aux>  
<Alarms, Zone Blank>  
<Other>  
EXIT  
Backlight comp  
Zoom limit  
Reset camera  
<Gain/AGC>  
<Auto-iris>  
<Next>  
Off  
x72  
Shutter speed  
Auto  
Auto focus mode Auto  
<IR Filter>  
<Sharpness>  
<White balance>  
Previous  
Exit  
Exit  
There are several electronic shutter speed settings:  
Auto  
1/4  
1/8  
1/15  
1/30  
1/60  
1/125  
1/180  
1/250  
1/500  
1/1000  
1/2000  
1/4000  
1/10,000  
In the Auto setting the camera controls the shutter speed automatically. Increasing the shut-  
ter speed lowers the light sensitivity, but rapidly moving objects will be less blurred as the  
speed is increased.  
To change the electronic shutter speed settings:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Camera.  
3. Press the Iris Open button to enter the Camera menu.  
4. Position the cursor (>) beside Next.  
5. Press the Iris Open button to go to the Next menu.  
6. Position the cursor (>) beside Shutter Speed.  
7. Press the Iris Open button.  
8. The cursor moves to the right, beside the current shutter speed.  
9. Move the joystick up or down to choose the shutter speed.  
10. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
Pelco Manual C2423M (5/00)  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SLOW SHUTTER MODE  
Main Menu  
Camera Menu  
Next Menu  
Slow shutter mode Auto  
<Camera>  
<Line Sync>  
<Power Up>  
<Aux>  
<Alarms, Zone Blank>  
<Other>  
Backlight comp  
Zoom limit  
Reset camera  
<Gain/AGC>  
<Auto-iris>  
<Next>  
Off  
x72  
Shutter speed  
Auto  
Auto focus mode Auto  
<IR Filter>  
<Sharpness>  
<White balance>*  
Previous  
EXIT  
Exit  
Exit  
Slow shutter mode slows the frame rate, producing a digital color picture sensitive to low  
light conditions. The picture may appear rough or smeared, depending on the distance and  
motion of the viewed image.  
There are two settings in the slow shutter mode:  
Auto - Slow shutter mode is enabled.  
Off - Slow shutter mode is disabled.  
To change the slow shutter mode:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Camera.  
3. Press the Iris Open button to enter the Camera menu.  
4. Position the cursor (>) beside Next.  
5. Press the Iris Open button to go to the Next menu.  
6. Position the cursor (>) beside Slow Shutter mode.  
7. Press the Iris Open button.  
8. The cursor moves to the right.  
9. Move the joystick up or down to toggle between Auto and Off.  
10. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the mode.  
24  
Pelco Manual C2423M (5/00)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WHITE BALANCE  
Main Menu  
Camera Menu  
Next Menu  
White Balance Menu  
Slow shutter mode  
Shutter speed  
Auto focus mode  
<IR Filter>  
<Sharpness>  
<White balance>  
Previous  
Auto  
Auto  
Auto  
<Camera>  
<Line Sync>  
<Power Up>  
<Aux>  
<Alarms, Zone Blank>  
<Other>  
Backlight comp  
Off  
x72  
Zoom limit  
Reset camera  
<Gain/AGC>  
<Auto-iris>  
<Next>  
Auto white bal  
Red bal level  
Blue bal level  
Exit  
On  
- -  
- -  
EXIT  
Exit  
Exit  
The settings for white balance are as follows:  
Auto white bal  
Red bal level  
Blue bal level  
To change the white balance settings:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Camera.  
3. Press the Iris Open button to enter the Camera menu.  
4. Position the cursor (>) beside Next.  
5. Press the Iris Open button to go to the Next menu.  
6. Position the cursor (>) beside White Balance.  
7. Press the Iris Open button. The White Balance menu appears.  
8. Position the cursor (>) beside one of the following choices and press the Iris Open button.  
AUTO WHITE BALANCE - The cursor moves to one of two choices: Auto or Off.  
Move the joystick up or down to toggle between them. Press the Iris Open button to  
select the choice, or press the Iris Close button if you do not want to change the setting.  
RED BALANCE and BLUE BALANCE LEVELS - The cursor moves to a numeric  
value, ranging from 0 through 255. Move the joystick up or down to a value. As you  
change the value, you can see the color change on your monitor. Press the Iris Open  
button to select the value, or press the Iris Close button if you do not want to change the  
setting. If Auto White Balance is on, it changes to off when you select a new value.  
ZONES  
The Spectra II dome is capable of eight zones, each with a 20-character label. Depending  
on the controller, you can define the zone size and define any zone as “blanked” for video  
when the camera pans into the zone area.  
Zones can be programmed to overlap each other, although this is not recommended. If you  
program two zones to overlap, the title of the zone with the highest priority (zone 8 is the  
hiest, zone 1 is the lowest) will be displayed in the overlap area. The same applies to zone  
blanking. For other information on programming zones, refer to the documentation for your  
control system.  
Pelco Manual C2423M (5/00)  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ZONE BLANK  
Main Menu  
Alarms, Zone Blank Menu  
Zone Blank Menu  
Video Blank Zone 1Off  
<Camera>  
<Line Sync>  
<Power Up>  
<Aux>  
<Alarms, Zone Blank>  
<Other>  
2Off  
3Off  
4Off  
5Off  
6Off  
7Off  
8Off  
Alarm resume  
Alarm dwell sec  
<Alarm priority>  
<Alarm pattern>  
<Zone blank>  
Exit  
Off  
5
EXIT  
Exit  
This feature lets you define any of eight zones as blanked for video when the camera pans  
into the zone area. There are two choices:  
On - Enables video blanking.  
Off - Disables video blanking.  
To change the blank zone setting:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Alarms, Zone Blank.  
3. Press the Iris Open button to enter the Alarms, Zone Blank menu.  
4. Position the cursor (>) beside Zone Blank.  
5. Press the Iris Open button to enter the Zone Blank menu.  
6. Position the cursor (>) beside the number of the zone for which you want to set the  
blank option.  
7. Press the Iris Open button. The cursor moves to the right, beside the word On or Off.  
8. Move the joystick up or down to toggle between the words On and Off.  
9. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
ZOOM LIMIT  
Main Menu  
<Camera>  
<Line Sync>  
<Power Up>  
<Aux>  
Camera Menu  
Backlight comp  
Zoom limit  
Reset camera  
<Gain/AGC>  
<Auto-iris>  
<Next>  
Off  
x72  
<Alarms, Zone Blank>  
<Other>  
EXIT  
Exit  
The Spectra II is a 72X zoom camera (18X optical zoom and 4X electronic zoom) can be set  
for 18X, 36X, 54X, or 72X.  
To change the zoom limit:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Camera.  
3. Press the Iris Open button to enter the Camera menu.  
4. Position the cursor (>) beside Zoom Limit.  
5. Press the Iris Open button. The cursor moves to the right, beside the current zoom limit.  
6. Move the joystick up or down to choose the zoom limit.  
7. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
NOTE: The Spectra II  
Color/Black and White  
camera cannot do electronic  
zoom in a pattern. Optical  
zoom will operate in a  
pattern.  
26  
Pelco Manual C2423M (5/00)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
DOME CLEANING  
Clean the acrylic dome as necessary to maintain a clear picture. Be careful not to scratch the  
surfaces of the dome.  
Exterior Surface - Clean the dome’s exterior surface with a nonabrasive cleaning cloth and  
cleaning agent that is safe for acrylic. Either liquid or spray cleaner/wax suitable for fine  
furniture is acceptable.  
Interior Surface (Except Chrome or Gold) - Clean the same as the exterior surface.  
Interior Surface (Chrome or Gold) - The inside surface of a chrome or gold dome is easily  
scratched. Use the following precautions to maintain the dome’s surface.  
1.  
2.  
Always handle the dome from the outside of its circular flange.  
Never touch the coated inside surface. The acid in your fingerprints will eventually etch  
the coating if the fingerprints are not carefully removed according to the recommended  
cleaning procedure in item 5.  
3.  
4.  
If dust or other contaminants accumulate on the dome’s interior, remove the debris with  
compressed air. Compressed air cans are available from photographic equipment or  
electronic supply dealers.  
If heavy residue accumulates and cannot be removed with air pressure, rinse with water  
and immediately dry with air pressure so that water spots will not remain. Avoid wiping the  
coated surface with direct hand pressure - it will easily abrade unless extreme care is  
taken. Once scratched, the dome cannot be recoated.  
5.  
If internal wiping is necessary, avoid hand rubbing. Instead, make a wick as follows:  
Use a very soft paper towel. Roll a section into a tightly wound tube. Tear the tube in half,  
and wet the fuzzy end of the wick with a solution of isopropyl alcohol diluted with water.  
Hold the dome with its opening facing downward and wipe the interior of the dome with  
the wet end of the wick. Use a circular motion, starting from the outside and spiraling into  
the center. Use a new wick for each two passes over the dome.  
SERVICE MANUAL  
If you need to service your unit, obtain a service manual in one of the following ways:  
Go to Pelco’s web site at ftp://www.pelco.com and find service manual C1455SM-B.  
Contact Pelco’s Literature Department and request service manual C1455SM-B.  
SPECIFICATIONS  
MECHANICAL  
Pan Movement:  
360° continuous pan rotation  
Vertical Tilt:  
Unobstructed +2° to -92°  
Manual Pan/Tilt Speeds*  
Pan:  
Tilt:  
0.1°-80°/sec manual operation, 150°/sec turbo  
0.1°-40°/sec  
Preset Speeds  
Pan:  
250°/sec  
Tilt:  
200°/sec  
* For variable-speed operation an appropriate controller is required. With fixed-speed  
controllers, pan/tilt speed is 24°/sec. The CM6700 controller with the KBD200 keyboard has  
programmable fixed speeds.  
CAMERA  
Signal Format:  
NTSC (model DD5BCBW)  
PAL (model DD5BCBW-X)  
2:1 interlace  
Scanning System:  
Image Sensor:  
1/4-inch interline transfer CCD  
Pelco Manual C2423M (5/00)  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Effective Pixels  
NTSC:  
PAL:  
768 (H) x 494 (V)  
752 (H) x 582 (V)  
Horizontal  
Resolution:  
Lens  
>470 TV lines  
Minimum f-stop:  
Focal Length:  
Zoom Ratio:  
Digital Slow Shutter:  
Horizontal  
Angle of View:  
MTBF:  
F1.4  
4.1 mm to 73.8 mm optical  
18X optical zoom, 4X electronic zoom  
Auto/manual speed selection  
48° (at 4.1 mm wide zoom), 2.7° (at 73.8 mm telephoto zoom)  
>500,000 cycles at room temperature (zoom, focus, irs)  
Automatic and manual override  
Focus:  
Sensitivity:  
.2 lux at 1/4-second shutter speed (color)  
.2 lux at 1/60-second shutter speed (black & white)  
AC line lock, phase adjustable via remote control*  
Automatic with manual override*  
Automatic (electronic iris)/manual  
1/4 to 1/10,000*  
Sync System:  
White Balance:  
Shutter Speed  
NTSC:  
Color/B&W PAL:  
Iris Control:  
Gain Control:  
Video Output  
NTSC:  
1/3 to 1/10,000*  
Automatic with manual override*  
Automatic with manual override*  
.714V ± .07V (100 IRE ± 10 IRE)  
PAL:  
.7V ± .07V  
Signal to Noise Ratio:  
>46 dB  
* Manual control of camera setup functions can be done with CM6700, CM8500, CM9500,  
CM9760 and MPT9500 controllers, but not with CM7500, MPT9000 or KBD9000 controllers.  
(Design and product specifications subject to change without notice.)  
PRODUCT WARRANTY AND RETURN INFORMATION  
WARRANTY  
Pelco will repair or replace, without charge, any merchandise proved defective in material or  
workmanship for a period of one year after the date of shipment.  
If  
a
warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or  
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following  
information:  
1. Model and serial number  
Exceptions to this warranty are as noted below:  
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number  
3. Details of the defect or problem  
Five years on FT/FR8000 Series fiber optic products.  
Three years on Genex® Series products (multiplexers, server, and keyboard).  
If there is a dispute regarding the warranty of a product which does not fall under the  
warranty conditions stated above, please include a written explanation with the product  
when returned.  
Three years on Camclosure® and fixed camera models, except the CC3701H-2,  
CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models,  
which have a five-year warranty.  
Method of return shipment shall be the same or equal to the method by which the item was  
received by Pelco.  
Two years on standard motorized or fixed focal length lenses.  
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series  
fixed dome products.  
RETURNS  
In order to expedite parts returned to the factory for repair or credit, please call the factory at  
(800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned  
for credit, and RA number if returned for repair).  
Two years on Spectra®, Esprit®, ExSite, and PS20 scanners, including when used in  
continuous motion applications.  
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).  
All merchandise returned for credit may be subject to a 20% restocking and refurbishing  
charge.  
Eighteen months on DX Series digital video recorders, NVR300 Series network video  
recorders, and EnduraSeries distributed network-based video products.  
Goods returned for repair or credit should be clearly identified with the assigned CA or RA  
number and freight should be prepaid. Ship to the appropriate address below.  
One year (except video heads) on video cassette recorders (VCRs). Video heads will be  
covered for a period of six months.  
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:  
Service Department  
Pelco  
Six months on all pan and tilts, scanners or preset lenses used in continuous motion  
applications (that is, preset scan, tour and auto scan modes).  
3500 Pelco Way  
Clovis, CA 93612-5699  
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco  
shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,  
California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident  
are not covered under this warranty.  
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are  
instructed to return goods to the USA, you may do one of the following:  
If the goods are to be sent by a COURIER SERVICE, send the goods to:  
Pelco  
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from  
the specific use or application made of the Products. Pelcos liability for any claim, whether  
based on breach of contract, negligence, infringement of any rights of any party or product  
liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for  
such Products. In no event will Pelco be liable for any special, incidental or consequential  
damages (including loss of use, loss of profit and claims of third parties) however caused,  
whether by the negligence of Pelco or otherwise.  
3500 Pelco Way  
Clovis, CA 93612-5699 USA  
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:  
Pelco c/o Expeditors  
473 Eccles Avenue  
The above warranty provides the Dealer with specific legal rights. The Dealer may also have  
additional rights, which are subject to variation from state to state.  
South San Francisco, CA 94080 USA  
Phone: 650-737-1700  
Fax: 650-737-0933  
REVISION HISTORY  
Manual # Date  
C2423M 5/00  
Comments  
Original version.  
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco.  
Endura and ExSite are trademarks of Pelco.  
© Copyright 2000, Pelco.  
All rights reserved. U.S. Patent No. 5,931,432.  
28  
Pelco Manual C2423M (5/00)  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Peavey Guitar Forum AX User Manual
Peavey Music Mixer XM 4 User Manual
Philips TV Cables SWA2511 User Manual
Philips Video Game Sound System SGP6031BB 27 User Manual
Philips Work Light P 5338 G User Manual
Planet Technology Network Card WNL 9500 User Manual
Planet Technology Security Camera ICA 106 User Manual
Primera Technology Answering Machine 9900CW User Manual
ProForm Home Gym PFEL29240 User Manual
PYLE Audio Portable Speaker PM57 User Manual