Pelco Home Security System C1306M D 7 09 User Manual

I N S T A L L A T I O N  
®
ExSite EHXM Series  
Explosionproof  
Fixed System  
C1306M-D (7/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Important Safety Instructions  
1. Read these instructions.  
2. Keep these instructions.  
3. Heed all warnings.  
4. Follow all instructions.  
5. Do not block any ventilation openings. Install in accordance with the manufacturers instructions.  
6. To reduce the risk of ignition of hazardous atmospheres, disconnect the equipment from the supply circuit before opening. Keep assembly  
tightly closed when in operation.  
7. The maximum ambient temperature range is -76° to 140°F (-60° to 60°C).  
8. Only use attachments/accessories specified by the manufacturer.  
9. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-  
supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or  
moisture, does not operate normally, or has been dropped.  
10. Installation should be done only by qualified personnel and conform to all local codes.  
11. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not  
be installed where exposed to rain and moisture.  
12. Use only installation methods and materials capable of supporting four times the maximum specified load.  
13. Use stainless steel hardware to fasten the mount to outdoor surfaces.  
14. AN ALL-POLE MAINS SWITCH with a contact separation of at least 3 mm in each pole shall be incorporated in the electrical installation of  
the building.  
15. A readily accessible disconnect device shall be incorporated in the building installation wiring.  
16. CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform  
any servicing other that contained in the operating instructions unless you are qualified to do so.  
17. Only use replacement parts recommended by Pelco.  
18. A certified flameproof, "d," sealing device such as a stopping box with setting compound shall be provided, either in the flameproof  
enclosure or immediately at the entrance thereto.  
19. For ambient temperatures below 14°F ( -10°C) use field wiring suitable for both minimum and maximum ambient temperature.  
The product and/or manual may bear the following marks:  
WARNING: This symbol indicates that dangerous voltage constituting a risk of electric shock  
is present within this unit.  
CAUTION:  
RISK OF ELECTRIC SHOCK.  
DO NOT OPEN.  
This symbol indicates that there are important operating and maintenance instructions in the  
literature accompanying this unit.  
WARNING: HAZARDOUS MOVING PARTS. KEEP FINGERS AND OTHER BODY PARTS AWAY.  
WARNING: To reduce the risk of ignition of hazardous atmospheres, disconnect the  
equipment from the supply circuit before opening. Keep assembly tightly closed when  
operating.  
WARNING: To reduce the risk of ignition of hazardous atmospheres, conduit runs must have  
a sealing fitting connected within 2 inches of the enclosure.  
TO REDUCE THE RISK OF IGNITION DO NOT OPEN WHEN AN EXPLOSIVE GAS ATMOSPHERE  
MAY BE PRESENT.  
C1306M-D (7/09)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Getting Started  
Thank you for purchasing Pelco’s ExSite® EHXM Series explosionproof system. This manual includes instructions for installing all the components  
of the system. Once the system installation is complete, refer to the operation/programming manual for instructions on how to operate and  
program your system.  
METHODS OF INSTALLATION  
The system can be installed in a standard or inverted position. When installed for inverted operation, the camera orientation and controller  
functions are reconfigured for normal operation through the system’s software. Hardware adjustment is not required for inverted operation.  
Refer to Figure 1 for installation methods.  
Figure 1. Methods of Installation  
WARNINGS:  
Total weight of the system is 34.7 lb (15.71 kg). Use caution when lifting and assembling the enclosure component on the power  
module. It is recommended that non-slip gloves be worn during installation.  
Do not turn the body of the enclosure more than 200° in either direction or damage to the power module cable may occur.  
4
C1306M-D (7/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Install the Power Module  
Attach the power module to the mounting surface. Use only installation methods and materials capable of supporting four times the maximum  
specified load of the system (140 lb/63.5 kg).  
NOTE: If required, install the optional TXB translator, fiber module, or UTP board before installing the power module. Refer to the installation  
instructions supplied with the TXB translator, fiber module, or UTP board for installation instructions.  
To install the power module, refer to Figure 2 and do the following:  
1. Make sure the threads of the power module and the threads of the supplied M10 x 16 mm stainless steel bolts are free of dirt and debris.  
2. Apply a generous amount of thread locking compound (supplied) to the threads of the power module and the threads of the stainless steel  
bolts.  
3. Face the conduit fitting of the power module towards the mating conduit fitting of the installation.  
4. Use the supplied 8 mm Allen wrench to secure the power module to the mounting surface with four M10 x 16 mm stainless steel bolts and  
lock washers. Tighten the bolts to 25 to 27 ft-lb (34 to 37 Nm). The thread locking compound supplied must cure for one hour. Allow for this  
cure period prior to completing the installation.  
NOTE: Figure 2 shows the power module  
being installed on a PXM100 pedestal mount  
(not supplied).  
Figure 2. Attach Power Module to Mounting Surface  
C1306M-D (7/09)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CONNECT WIRING  
DANGER: Do not connect the power module to a supply circuit unless all ExSite system components (enclosure, camera module, and  
power module) are installed.  
Refer to the following information to connect the wires and cables as required.  
WARNING: When installing this unit, provide access to the communication wires (TX+ and TX-) to allow connection to the system for  
future software upgrades. Connectors must be installed so that the integrity of the hazardous location is maintained.  
These communication wires are required even if the system uses Coaxitron® control.  
Maximum wire distance for RS-422 data wires is 4,000 ft (1,219 m).  
NOTES:  
Relay 3 is allocated specifically for an external washer (not supplied by Pelco).  
All relays are specified for 32 VDC, 0.5 A.  
Wiring/cable for UTP and fiber optic are not provided on the wire harness. The installer must provide UTP and fiber optic connections.  
Power Connections 24 VAC  
Configuration of Wire Harness  
Wire Color  
Red  
Function  
AC Hi  
Wire Color  
White/Orange  
White/Blue  
Red  
Function  
TX+  
TX-  
Black  
AC Low  
RX+  
Green  
RX-  
Power Connections 100-240 VAC  
Violet/White  
White/Red  
Relay 3 NC (washer only)  
Relay 3 COM (washer only)  
Relay 3 NO (washer only)  
Relay 2 NC  
Relay 2 COM  
Relay 2 NO  
Relay 1 NC  
Relay 1 COM  
Relay 1 NO  
Alarm COM  
Alarm 7  
Wire Color  
Black  
Function  
AC Hi  
AC Low  
Green/Black  
Gray/White  
Yellow  
White  
Green/Yellow  
Earth Ground  
Violet  
Wiring Distances  
Brown  
The following are the recommended maximum distances for 24 VAC and  
100-240 VAC applications and are calculated with a 10 percent voltage drop.  
(Ten percent is generally the maximum allowable voltage drop for AC-powered  
devices.)  
Gray  
White/Yellow/Black  
White/Black/Green  
White/Red/Black  
White/Brown/Black  
Orange  
Wire Gauge  
Power  
18  
16  
14  
12  
Alarm 6  
(1.0 mm2)  
(1.5 mm2)  
(2.5 mm2)  
(3.5 mm2)  
Alarm 5  
27 ft  
(8 m)  
43 ft  
(13 m)  
120 ft  
(36 m)  
69 ft  
(21 m)  
190 ft  
(58 m)  
110 ft  
(33 m)  
310 ft  
(94 m)  
24 VAC  
White/Orange/Black  
White/Blue/Black  
White/Brown  
White/Black  
Alarm 4  
Alarm 3  
100-240  
VAC  
75 ft  
(23 m)  
Alarm 2  
Alarm 1  
NOTE: Power consumption is 120 VA per unit. Use a power source with a  
minimum of 150 VA.  
Video Coaxial Cable Requirements  
Cable Type*  
RG59/U  
Maximum Distance  
750 ft (229 m)  
RG6/U  
1,000 ft (305 m)  
1,500 ft (457 m)  
RG11/U  
*Cable requirements:  
75-ohm impedance  
All-copper center conductor  
All-copper braided shield with 95% braid coverage  
6
C1306M-D (7/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
DIP SWITCH SETTINGS  
Configure the receiver address, termination, and baud setting for the system. The DIP switches to configure these settings are located on the top  
of the power module.  
NOTE: No DIP switch settings are required for Coaxitron control.  
Figure 3 shows the default settings for the DIP switches. Refer to the following to configure the ExSite system settings.  
SW1-1 is set to the ON position.  
All other switches are set to the OFF position.  
7 8  
1
2
3
4
5
6
1
4
6
7 8  
1
2
3
5
ON  
SW3  
SW1  
SW2  
on  
on  
Figure 3. Default DIP Switch Settings  
PROTOCOL SETTINGS  
The ExSite system automatically detects the type of protocol. No switch settings are required to set Coaxitron or RS-422 P and D protocols.  
RECEIVER ADDRESS SETTINGS (SW1)  
The default address is 2 for P protocol. Refer to Table A for address settings that use P protocol. Maximum number of receivers is 32.  
The default address is 1 for D protocol. Refer to Table B for address settings that use D protocol. Maximum number of receivers is 254.  
TERMINATION SETTING (SW2)  
When connecting more than one ExSite system to a single controller, terminate the unit farthest from the controller. Termination is required only  
for the last unit in the series. The unit is shipped from the factory in the unterminated OFF position. To terminate the unit, set the SW2 switch to  
the ON position.  
BAUD SETTINGS (SW3)  
Pelco’s D-type controllers are set for 2400 baud. The default setting for the unit is 2400 baud. If you are using a Pelco D-type controller, do not  
reset the SW3 switches.  
P-type controllers can operate at 2400, 4800, and 9600 baud. Set the SW3 switches (6, 7, and 8), located on the top of the power module, to the  
same baud as the P-type controller.  
Switch Settings for SW3  
Switch Number  
2400 Baud  
SW3-6  
Off  
SW3-7  
Off  
SW3-8  
Off  
4800 Baud  
On  
Off  
Off  
9600 Baud  
Off  
On  
Off  
C1306M-D (7/09)  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Table A. P Protocol Receiver Address  
SWITCH SETTING  
ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8  
SWITCH SETTING  
ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8  
1
2
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
Table B. D Protocol Receiver Address  
SWITCH SETTING  
ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8  
SWITCH SETTING  
ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8  
1
2
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
3
ON  
4
ON  
5
ON  
6
ON  
7
ON  
8
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
9
ON  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
(Continued on next page)  
8
C1306M-D (7/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Table B. D Protocol Receiver Address (Continued)  
SWITCH SETTING  
ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8  
SWITCH SETTING  
ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8  
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
62  
63  
64  
65  
66  
67  
68  
69  
70  
71  
72  
73  
74  
75  
76  
77  
78  
79  
80  
81  
82  
83  
84  
85  
86  
87  
88  
89  
90  
91  
92  
93  
94  
95  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
96  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
97  
ON  
98  
ON  
99  
ON  
100  
101  
102  
103  
104  
105  
106  
107  
108  
109  
110  
111  
112  
113  
114  
115  
116  
117  
118  
119  
120  
121  
122  
123  
124  
125  
126  
127  
128  
129  
130  
131  
132  
133  
134  
135  
136  
137  
138  
139  
140  
141  
142  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
(Continued on next page)  
C1306M-D (7/09)  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table B. D Protocol Receiver Address (Continued)  
SWITCH SETTING  
ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8  
SWITCH SETTING  
ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8  
143  
144  
145  
146  
147  
148  
149  
150  
151  
152  
153  
154  
155  
156  
157  
158  
159  
160  
161  
162  
163  
164  
165  
166  
167  
168  
169  
170  
171  
172  
173  
174  
175  
176  
177  
178  
179  
180  
181  
182  
183  
184  
185  
186  
187  
188  
189  
190  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
191  
192  
193  
194  
195  
196  
197  
198  
199  
200  
201  
202  
203  
204  
205  
206  
207  
208  
209  
210  
211  
212  
213  
214  
215  
216  
217  
218  
219  
220  
221  
222  
223  
224  
225  
226  
227  
228  
229  
230  
231  
232  
233  
234  
235  
236  
237  
238  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
(Continued on next page)  
10  
C1306M-D (7/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table B. D Protocol Receiver Address (Continued)  
SWITCH SETTING  
ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8  
SWITCH SETTING  
ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8  
239  
240  
241  
242  
243  
244  
245  
246  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
247  
248  
249  
250  
251  
252  
253  
254  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
C1306M-D (7/09)  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Install the Camera Module  
To install the camera module, do the following:  
1. Refer to Figure 4. Loosen the set screw at the back of the camera enclosure with the provided 1.5 mm Allen wrench.  
SET SCREW  
Figure 4. Loosen Set Screw  
WARNING: To avoid thread damage carefully remove the back of the camera enclosure. Never use force to remove the back of the camera  
enclosure.  
2. Use the supplied spanner wrench to loosen the back of the camera enclosure (refer to Figure 5). Once the back is loose, use your hands to  
continue to loosen it until it can be removed.  
CAMERA  
ENCLOSURE  
BACK  
SPANNER  
WRENCH  
Figure 5. Remove Back Cap of Camera Enclosure  
12  
C1306M-D (7/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
WARNING: Do not force the camera module into the camera enclosure.  
3. Slide the camera module into the camera enclosure. Refer to Figure 6 to position the camera module properly in the camera enclosure.  
Carefully mate the cameras power connector to the mating connector located inside the camera enclosure.  
Models with a wiper: The tab located inside the camera enclosure must be pointing down before installing the camera module (refer to  
Figure 6). To position the tab, place the wiper, located at the front of the camera enclosure, in the center of the viewing window (refer to  
TAB  
CENTER  
NOTCHES  
CAMERA  
MODULE  
CAMERA  
ENCLOSURE  
Figure 6. Install Camera Module  
CENTER WIPER  
Figure 7. Center Wiper  
C1306M-D (7/09)  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
4. Models with a wiper: Refer to Figure 8 and do the following to install the arm of the wiper:  
a. Place the supplied green bushing on the stud located behind the handle of the camera module. The bushing should be in the same  
orientation as shown in Figure 8.  
b. Install the wiper arm. Place the ridge of the arm in the notch of the camera enclosure tab and the slot of the arm over the green  
bushing.  
5. Secure the camera module (and wiper) with the supplied 8-32 Phillips flat head screw (refer to Figure 8).  
SET TAB IN  
CENTER POSITION  
8-32 PHILLIPS FLAT  
HEAD SCREW  
ARM  
CAMERA  
MODULE  
HANDLE  
STUD  
BUSHING  
Figure 8. Install Wiper Arm  
WARNINGS:  
To avoid thread damage carefully install the back cap to the camera enclosure.  
Never force the back cap onto the end of the camera enclosure.  
When installation is completed there should be no gap between the back cap and the camera enclosure.  
6. Reinstall the back cap on the enclosure by doing the following:  
a. Use your hands to turn the back cap clockwise until you can no longer turn it with your hands. The back cap should turn easily until it  
comes in contact with the O-ring. If it does not turn easily the threads are not aligned and thread damage will occur.  
b. Continue tightening the back cap with the supplied spanner wrench. There should be no gap between the back cap and the enclosure  
when the back cap is tightened and properly installed.  
c. Once the back cap is installed, secure the back cap with the set screw using the supplied 1.5 mm Allen wrench.  
14  
C1306M-D (7/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Install the Enclosure and Set Pan Position  
1. Check for proper seating of the power module seal. Make sure the seal is fully seated in the groove on the top of the power module.  
POWER MODULE SEAL  
POWER MODULE  
Figure 9. Factory-Installed Power Module Seal  
WARNING: Use caution when attaching the enclosure unit to the power module. If the grooves on the top of the power module are  
damaged, the integrity of the unit could be compromised.  
2. Refer to Figure 10 and attach the enclosure unit to the power module. Align the pins of the enclosure unit with the holes of the power  
module. Carefully mate the enclosure connector to the power module connector.  
LOCKING  
RING  
PIN  
HOLE  
Figure 10. Attach the Enclosure Unit to the Power Module  
WARNINGS:  
Total weight of the enclosure component is 34.7 lb (15.71 kg). Use caution when lifting and assembling the pan and tilt component on  
the power module.  
The weight of the enclosure unit must be safely supported during installation.  
It is recommended that non-slip gloves be worn during installation.  
Avoid thread damage. Never use force when assembling and tightening the threaded components of the system.  
3. Turn the body of the enclosure to the left or right to set the pan position of the unit.  
WARNING: Do not turn the body of the enclosure more than 200° in either direction or damage to the internal power module cable may occur.  
4. With your hands carefully thread the enclosure’s locking ring on the threads of the power module until the threads are completely engaged.  
5. Use the supplied spanner wrench to tighten the locking ring and fix the position of the enclosure. After the locking ring has been tightened,  
tap the end of the handle of the wrench with a hammer or the palm of your hand to ensure a secure fit. Make sure that the pan position is  
maintained when tightening the locking ring. Tighten the set screw of the locking ring with the supplied 2 mm Allen wrench to secure the  
locking ring.  
C1306M-D (7/09)  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Set the Tilt Angle of the Camera Module  
1. Place a 41 mm open end or crescent wrench on the tilt locking nut and a 21 mm open end wrench on the tilt shaft (refer to Figure 11).  
TILT LOCK  
NUT  
SET SCREW  
TILT SHAFT  
Figure 11. Set the Tilt Position  
2. Hold the tilt shaft in position with the 21 mm wrench, and then turn the 41 mm wrench to loosen the tilt locking nut.  
3. Adjust the tilt position of the camera module by moving the camera module up or down.  
4. Continue to hold the tilt shaft with the 21 mm wrench and then tighten the tilt locking nut to set the tilt position of the camera module.  
Make sure the tilt position is maintained when tightening the locking ring. Tighten the set screw of the locking nut with the supplied 2 mm  
Allen wrench to secure the locking nut.  
16  
C1306M-D (7/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Install the Sun Shroud  
1. Place the supplied nylon washers on the 6-32 Phillips pan head screws. Refer to Figure 12.  
2. Align the mounting holes of the sun shroud with the holes on top of the camera enclosure.  
3. Use the supplied nylon washers and screws to secure the sun shroud to the camera enclosure.  
NYLON  
WASHER  
6-32 PHILLIPS PAN  
HEAD SCREW  
SUN SHROUD  
Figure 12. Install the Sun Shroud  
C1306M-D (7/09)  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Maintenance  
CAMERA MODULE REPLACEMENT  
DANGER: To reduce the risk of ignition of hazardous atmospheres, disconnect the equipment from the power supply before opening.  
Keep assembly tightly closed when operating.  
To replace the camera module, do the following:  
1. Remove the back cap of the camera enclosure. Refer to Figure 13 and do the following:  
a. Loosen the set screw with a 1.5 mm Allen wrench.  
b. Use the supplied spanner wrench to loosen the back cap of the camera enclosure. Once the back is loose, use your hands to continue  
to loosen it until it can be removed.  
CAMERA  
ENCLOSURE  
BACK  
SET SCREW  
SPANNER  
WRENCH  
Figure 13. Remove Back Cap of Camera Enclosure  
2. Remove the 8-32 Phillips flat head screw that secures the camera module inside the camera enclosure (refer to Figure 14).  
SET TAB IN  
CENTER POSITION  
8-32 PHILLIPS FLAT  
HEAD SCREW  
ARM  
CAMERA  
MODULE  
HANDLE  
STUD  
BUSHING  
Figure 14. Remove or Install Camera Module  
18  
C1306M-D (7/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
3. Models with a wiper: Remove the wiper arm and the green bushing from the unit (refer to Figure 14).  
4. Slide the camera module out of the enclosure.  
WARNING: Never force the camera module into the enclosure.  
5. Install the new camera module by doing the following:  
Slide the camera module into the camera enclosure. Refer to Figure 15 to position the camera module properly in the camera enclosure.  
Carefully mate the cameras power connector to the mating connector located inside the camera enclosure.  
Models with a wiper: The tab located inside the enclosure must be pointing down before installing the camera module (refer to  
Figure 15). To position the tab, place the wiper, located at the front of the camera enclosure, in the center of the viewing window (refer to  
TAB  
CENTER  
NOTCHES  
CAMERA  
MODULE  
CAMERA  
ENCLOSURE  
Figure 15. Install Camera Module  
CENTER WIPER  
Figure 16. Center Wiper  
C1306M-D (7/09)  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
6. Models with a wiper: Refer to Figure 14 and do the following to reinstall the arm of the wiper:  
a. Reinstall the green bushing on the stud located behind the handle of the camera module.  
b. Reinstall the wiper arm. Place the ridge of the arm in the notch of the camera enclosure tab and the slot of the arm over the green  
bushing.  
7. Secure the camera module and the wiper arm with the 8-32 Phillips flat head screw (refer to Figure 14).  
WARNINGS:  
To avoid thread damage, carefully install the back cap to the enclosure.  
Never force the back cap onto the end of the enclosure.  
When installation is completed, there should be no gap between the back cap and the camera enclosure.  
8. Reinstall the back cap on the camera enclosure by doing the following:  
a. Use your hands to turn the back cap clockwise until you can no longer turn it with your hands. The back cap should turn easily until it  
comes in contact with the O-ring. If it does not turn easily, the threads are not aligned and thread damage will occur.  
b. Continue tightening the back cap with the supplied spanner wrench. There should be no gap between the back cap and the camera  
enclosure when the back cap is tightened and properly installed.  
c. After the back cap is installed, secure the back cap with the set screw using a 1.5 mm Allen wrench.  
20  
C1306M-D (7/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
ELECTRICAL  
Input Voltage  
24 VAC or 100-240 VAC, 50/60 Hz  
Input Voltage Range  
Power Consumption  
Heater and Defroster  
Electrical Connections  
10%  
Maximum 60 W (120 VA) per system  
Microprocessor controlled  
6-foot wire harness with connections for power, video, data control, alarm inputs, and auxiliary outputs  
MECHANICAL  
Cable Entry  
One 0.75-inch (1.91 cm) NPT threaded opening  
GENERAL  
Construction  
316L stainless steel  
Finish  
Electropolish  
Viewing Window  
Operating Temperature  
Unit Weight  
0.50-inch (12.7 mm) thick, soda-lime tempered glass  
-76° to 140°F (-60° to 60°C)  
34.7 lb (15.71 kg)  
Effective Projected Area (EPA)  
97.3 square inches  
CERTIFICATIONS  
Class I, Groups A, B, C, and D  
Class II, Groups E, F, G, T5  
Class I, Zone 1, AEx d IIC, Ex d IIC, T5  
BR-Ex d IIC, T5, IP66  
04/UL-BRAE-0027  
IECEx UL 04.0010X, Ex d IIC, T5  
DEMKO 04 ATEX 0413858  
0539  
II 2 G Ex d IIC, T5  
II 2 D Ex tD A21 IP66 T105°C  
(Tamb -60°C to +60°C)  
5.13  
11.5 (29.21)  
(13.03)  
4.91  
(12.47)  
10.5  
(26.8)  
0.75 NPT  
(1.91)  
13.1 (33.27)  
4 PLCS. TYP.  
10MM - 1.5MM X 14MM  
ON A 4.75-INCH DIA. B.C.  
EQUALLY SPACED  
3.354  
(8.52)  
NOTE: Values in parentheses are centimeters; all others are inches.  
C1306M-D (7/09)  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CAMERA/OPTICS  
Camera  
Day/Night (23X) Color  
NTSC, PAL  
2:1 Interlace  
1/4-inch progressive scan CCD  
LowLight(22X) Color  
NTSC, PAL  
2:1 Interlace  
1/4-inch EXview HADCCD  
Signal Format  
Scanning System  
Image Sensor  
Effective Pixels  
NTSC  
PAL  
768 (H) x 494 (V)  
752 (H) x 582 (V)  
768 (H) x 494 (V)  
752 (H) x 582 (V)  
Horizontal Resolution  
NTSC  
PAL  
540 TV lines  
540 TV lines  
>470 TV lines  
>460 TV lines  
Lens  
Zoom  
f/1.6 (focal length, 3.6~82.8 mm optical)  
23X optical, 10X digital  
f/1.6 (focal length, 4~88 mm optical)  
22X optical, 12X digital  
Zoom Speed  
2.9/4.2/5.8 seconds  
2.4/3.9/6.3 seconds  
Horizontal Angle of  
View  
54° at 3.6 mm wide zoom  
2.5° at 82.8 mm telephoto zoom  
47° at 4.0 mm wide zoom  
2.2° at 88 mm telephoto zoom  
Focus  
Automatic with manual override  
Automatic with manual override  
Maximum Sensitivity  
at 35 IRE  
NTSC  
0.025 lux at 1/2 sec shutter (color)  
0.1 lux at 1/60 sec shutter (B-W)  
0.004 lux at 1/2 sec shutter (B-W)  
0.02 lux at 1/2 sec shutter  
PAL  
0.025 lux at 1/1.5 sec shutter (color)  
0.1 lux at 1/50 sec shutter (B-W)  
0.004 lux at 1/1.5 sec shutter (B-W)  
0.02 lux at 1/1.5 sec shutter  
Sync System  
Internal/AC line lock, phase adjustable using  
remote control, V-Sync*  
Internal/AC line lock, phase adjustable using  
remote control, V-Sync*  
White Balance  
Automatic with manual override*  
Automatic with manual override*  
Shutter Speed  
NTSC  
PAL  
Automatic (electronic iris)/Manual  
1/2~1/30,000*  
1/1.5~1/30,000*  
Automatic (electronic iris)/Manual  
1/2~1/30,000*  
1/1.5~1/30,000*  
Iris Control  
Automatic Iris Control with manual override*  
Automatic Iris Control with manual override*  
Gain Control  
Video Output  
Video Signal to Noise  
Automatic/OFF*  
1 Vp-p, 75 ohms  
>50 dB  
Automatic/OFF*  
1 Vp-p, 75 ohms  
>50 dB  
*Manual control of camera setup functions can be done with CM6700, CM6800, CM8500, CM9500, CM9740, CM9760, CM9770,  
CM9780, KBD200A, KBD300A, and MPT9500 controllers, but not with CM7500, MPT9000, or KBD9000 controllers.  
22  
C1306M-D (7/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
PRODUCT WARRANTY AND RETURN INFORMATION  
WARRANTY  
Pelco will repair or replace, without charge, any merchandise proved defective in  
material or workmanship for a period of one year after the date of shipment.  
Pelco will warrant all replacement parts and repairs for 90 days from the date of  
Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid  
to a Pelco designated location. Repairs made necessary by reason of misuse,  
alteration, normal wear, or accident are not covered under this warranty.  
Exceptions to this warranty are as noted below:  
• Five years:  
Pelco assumes no risk and shall be subject to no liability for damages or loss  
resulting from the specific use or application made of the Products. Pelcos liability  
for any claim, whether based on breach of contract, negligence, infringement of  
any rights of any party or product liability, relating to the Products shall not exceed  
the price paid by the Dealer to Pelco for such Products. In no event will Pelco be  
liable for any special, incidental, or consequential damages (including loss of use,  
loss of profit, and claims of third parties) however caused, whether by the  
negligence of Pelco or otherwise.  
Fiber optic products  
TW3000 Series unshielded twisted pair (UTP) transmission products  
CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and  
MC3651H-2X camera models  
• Three years:  
Pelco-branded fixed camera models (CCC1390H Series, C10DN Series,  
C10CH Series, IP3701H Series, and IX Series)  
EH1500 Series enclosures  
Spectra® IV products (including Spectra IV IP)  
Camclosure® Series (IS, ICS, IP) integrated camera systems  
The above warranty provides the Dealer with specific legal rights. The Dealer may  
also have additional rights, which are subject to variation from state to state.  
DX Series digital video recorders, DVR5100 Series digital video recorders,  
Digital Sentry® Series hardware products, DVX Series digital video  
recorders, and NVR300 Series network video recorders  
Endura® Series distributed network-based video products  
Genex® Series products (multiplexers, server, and keyboard)  
PMCL200/300/400 Series LCD monitors  
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or  
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the  
following information:  
1. Model and serial number  
2. Date of shipment, P.O. number, sales order number, or Pelco invoice number  
3. Details of the defect or problem  
• Two years:  
If there is a dispute regarding the warranty of a product that does not fall under  
the warranty conditions stated above, please include a written explanation with  
the product when returned.  
Standard varifocal, fixed focal, and motorized zoom lenses  
DF5/DF8 Series fixed dome products  
Legacy® Series integrated positioning systems  
Spectra III, Spectra Mini, Spectra Mini IP, Esprit®, ExSite®, and PS20  
scanners, including when used in continuous motion applications.  
Method of return shipment shall be the same or equal to the method by which the  
item was received by Pelco.  
Esprit Ti and TI2500 Series thermal imaging products  
Esprit and WW5700 Series window wiper (excluding wiper blades).  
CM6700/CM6800/CM9700 Series matrix  
RETURNS  
To expedite parts returned for repair or credit, please call Pelco at (800) 289-9100  
or (559) 292-1981 to obtain an authorization number (CA number if returned for  
credit, and RA number if returned for repair) and designated return location.  
Digital Light Processing (DLP®) displays (except lamp and color wheel). The  
lamp and color wheel will be covered for a period of 90 days. The air filter is  
not covered under warranty.  
Intelli-M® eIDC controllers  
All merchandise returned for credit may be subject to a 20 percent restocking and  
refurbishing charge.  
• One year:  
Video cassette recorders (VCRs), except video heads. Video heads will be  
covered for a period of six months.  
• Six months:  
All pan and tilts, scanners, or preset lenses used in continuous motion  
applications (preset scan, tour, and auto scan modes).  
Goods returned for repair or credit should be clearly identified with the assigned  
CA or RA number and freight should be prepaid.  
12-23-08  
The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002/95/EC.  
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union  
regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.  
REVISION HISTORY  
Manual #  
C1306M  
Date  
8/05  
Comments  
Original version.  
C1306M-A  
C1306M-B  
C1306M-C  
C1306M-D  
7/06  
Updated for the new factory-installed power module seal (ECO 06-1400). Revised power module installation instructions. Removed Figure 9.  
Removed color reference to power module seal (ECO 06-14300). Added power module warning. Added Figure 9.  
Changed camera specs per CN22046.  
10/06  
11/08  
7/09  
Updated Important Safety Instructions section and added product certifications; UL certification requirement. Reference CN22827.  
Pelco, the Pelco logo, Endura, ExSite, Spectra, Genex, Esprit, Camclosure, Coaxitron, and Legacy are registered trademarks of Pelco, Inc.  
Spectra III is a trademark of Pelco, Inc.  
©Copyright 2009, Pelco, Inc. All rights reserved.  
LowLight is a trademark of Pelco, Inc.  
EXview HAD is a trademark of Sony Corporation.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Pelco, Inc. Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA  
USA & Canada Tel (800) 289-9100 Fax (800) 289-9150  
International Tel +1 (559) 292-1981 Fax +1 (559) 348-1120  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Pelican Water Dispenser WF4 User Manual
Philips Car Satellite Radio System SDV9201 17 User Manual
Philips Indoor Furnishings 44992 30 16 User Manual
Philips Telephone SE4502B 17 User Manual
Philips TV Antenna SDW1410GN User Manual
Philips TV VCR Combo 14 20PT1354 User Manual
Pioneer Blu ray Player BDP 43FD User Manual
Poulan Snow Blower 192044 User Manual
Powerware Power Supply 8 10 kVA User Manual
ProForm Home Gym PFEX39912 User Manual