C468M
INSTALLATION MANUAL
BKMT10,BKMT10/ 230,ANDBKMT10/ 24
BLOWER KITS
®
1.0 SCOPE
3.0 INSTALLATION
The information contained within this manual pertains
to the BKMT10, BKMT10/230, and BKMT10/24
blower kits.
Install the blower kit in either the HT10V or MT10P
enclosure as outlined below.
1. Remove the rear plate of the enclosure, and
then remove the camera sled.
Installation should be in accordance with all applicable
local and national electric codes, utilizing approved
materials only.
2. Assemble blower/blower bracket to sled as
shown in Figure 1, items 1–4.
2.0 DESCRIPTION
3. Install sled into enclosure.
The BKMT10, BKMT10/230, and BKMT10/24 are
continuous duty blower kits designed for use in either
the HT10V or MT10P liquid cooled enclosures.
4. Wire blower to power source using butt
splices provided.
5. Re-install rear plate of the enclosure.
2.1 MODELS
BKMT10
Blower kit, 6.7 watts @ 120 VAC,
60 Hz, 33 cfm
BKMT10/230
BKMT10/24
Blower kit, 8.9 watts @ 230 VAC,
50 Hz, 27 cfm
Blower kit, 1.92 watts @ 24 VDC
(AC rectified), 30 cfm
Item Description
Part Number
1
2
3
4
5
1/4-20 bolt
Fan bracket
Washer
Nut
Fan Securement
Assembly
Screw
ZH1/420X.750SFS
BK40004001COMP
ZH260X562X65C
ZH1/420NUTCHN
ZH4-40X.500SPP (Qty. 4)
ZH4LWSIS (Qty. 4)
ZH4-40NUTSH (Qty. 4)
Washer
Nut
6
Fans
24 VDC
120 VAC
230 VAC
EH4600105W3
EH4600115W3
EH4600123W3
Figure 1. BKMT10 Series Blower Kit Installation
REVISION A — 12/93
1
Download from Www.Somanuals.com. All Manuals Search And Download.
|