PINV4
PINV5
PINV6
OWNER’S MANUAL
POWER INVERTER
PINV4 600WATT
PINV5 800WATT
PINV6 1000WATT
Download from Www.Somanuals.com. All Manuals Search And Download.
FEATURES
PINV4 / PINV5 / PINV6
1. AC OUTLET
2. ON/OFF SWITCH
3. POWER ON LED
4. PROTECTION LED
5. BINDING POST TERMINAL
2
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION
- CAUTION : DO NOT USE THIS INVERTER WITH THE FOLLOWING:
• Small battery operated appliances such as RECHARGEABLE FLASHLIGHTS, SOME RECHARGEABLE
SHAVERS and NIGHT LIGHTS that are plugged directly into as RECEPTACLE TO RECHARGE
• BATTERY CHARGERS used with certain power tool battery packs. These chargers will have a WARNING
LABEL stating that DANGEROUS VOLTAGE ARE PRESENT AT THE CHARGERS BATTERY
TERMINALS.
-WARNING:
Batteries contain corrosive materials and present an Energy Hazard. To prevent irritation and burns, wear
protective wear and clothing, and take special care to ensure no metal tools or personal objects contact the
battery terminals.
-The Power Source Connection
The power source must provide between 10.3 to 15.6 Volts DC and must be able to supply the necessary
current to operate the load. The power source may be a battery or a well-regulated 12V/30A DC power
supply. To obtain the power source must deliver (in amperes), you can divide the power consumption of the
load (in watt) by 12 (the input voltage). For example, the load is rated at 600Watts, the power source must
be able to deliver: (150/12)=12.5 Amp.
The inverter is equipped with a heavy duty DC lighter plug that fits standard vehicle cigarette lighter and DC
power outlets. With this lighter plug, the inverter can power loads up to 600 Watts.
When continuously powering loads rated higher than 600 Watts, connect the inverter directly to a 12 Volt
battery, please use the provided battery clip cables (PINV4/ PINV5/ PINV6) to connect the inverter directly to
the 12 Volt power source.
While using the battery clip cable of PINV4 /PINV5 /PINV6, please follow these steps:
A. Cut the lighter plug off the PINV4 / PINV5 / PINV6 power cord.
B. Turn off the power switch and be sure no flammable fumes are present.
C. Connect the BLACK cable to the black post (-) and RED cable to the red post (+) on the rear of the
PINV4/ PINV5/PINV6. Then connect the BLACK battery chip to the NEGATIVE (-) terminal and RED
battery chip to the POSITIVE (+) terminal of the battery. The reverse polarity connection will result in a
blown fuse and may cause permanent damage to the inverter. Do not use the system with positive
electrical grounding.
D. Be sure to fasten all connections between battery chips and terminals.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
-The LED indicators
A. GREEN : It indicates the inverter is power on, the cooling fan (PINV4/ PINV5 / PINV6) is also activated,
and AC power will be delivered to the AC outlet.
B. RED : It indicates the inverter shutdown caused by low voltage, overload, or excessive temperature.
-The ON/OFF switch
It enables output AC power at the AC outlet when switched ON. It also acts as a manual reset for overload,
low battery voltage and overheat fault conditions. Reset occurs by switching OFF for 5 seconds after
automatic shout down then back ON again. This manual reset feature prevents unexpected or hazardous
restarting of connected AC loads.
-The AC outlet
Single and dual AC outlets are provided on one end of the PINV4, PINV5 and PINV6, make sure of the
power consumption required before plug in:
When operated from the directly connection to a 12 Volt battery (PINV4 / PINV5 / PINV6) Any combination
of 115 Volt AC products with a total power consumption of 600 Watts or less for PINV4 / PINV5 / PINV6
CAUTION:
• Do not connect to AC DISTRIBUTION WIRING. The inverter is designed for connection directly to
standard electrical and electronic equipment.
• Do not connect the inverter to household or RV AC distribution wiring.
• Do not connect the inverter to any AC load circuit in which the neutral conductor is connected to ground
(earth) or to the negative of DC (battery) source.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
BATTERY OPERATING TIME
The vehicle batteries are not intended for constant deep discharge, they are designed to provide brief
periods of very high current needed for engine starting. It is strongly recommended to start the vehicle
every hour or two to recharge battery before its capacity drops too low. Operating the inverter from a
vehicle battery until the low voltage alarm sounds will shorten the battery's life.
The inverter can operate whether or not the vehicle's engine is running, but the normal voltage drop that
occurs during starting may trigger the inverter's low voltage shutdown feature.
The use of a deep discharge battery is strongly advised for longer operating times. Its capacity should be
selected based on the desired operating time.
PROTECTION
SYMPTOMS
PROTECTION
The input reverse polarity
The fuse blown.
The low voltage battery (below DC 10V)
The unit auto shutdown.
The alarm sounds.
The RED LED lights.
The unit auto shutdown.
The RED LED lights.
The high input voltage (over DC 15.6V)
The overload
The overheat
5
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLE SHOOTING
SYMPTOM A: NO AC POWER OUTPUT, THE RED LED LIGHTS.
POSSIBLE CAUSES
SUGGESTION
The connected AC products are rated at more than 600 Watts Use the product with a total power rating
(PINV4) , 800 Watts (PINV5) or 1000 Watts (PINV6), the
overload shutdown occurred.
less than 600 Watts (PINV4) , 800 Watts
(PINV5) and 1000 Watts (PINV6) .
The connected AC products are rated at less than 600 Watts
Use the product not exceeds the inverter's
(PINV4) , 800 Watts (PINV5) or 1000 Watts (PINV6), the high surge capacity, 1200 Watts (PINV4) , 1600
starting surge causes the overload shutdown.
Watts (PINV5) and 2000 Watts (PINV6) .
The battery is discharged (alarm sounds)
The inverter overheated
Recharge battery.
Turn off the inverter and allow to cool for
15 minutes. Clear blocked fan (PINV4 /
PINV5 / PINV6) or remove the objects
covering the ventilation.
SYMPTOM B: NO AC POWER OUTPUT, NO LED LIGHTS ARE ON.
POSSIBLE CAUSES
SUGGESTION
The fuse of inverter is blown
Check to make sure the inverter is
connected to a power source with correct
voltage and polarity.
Replace fuse.
The inverter has been connected with reverse DC input
polarity.
The inverter needs repairment
if the probable damage has occurred.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
SYMPTOM C: THE LOW OUTPUT OF INVERTER IS MEASURED
POSSIBLE CAUSES
SUGGESTION
Battery voltage is too low below 10V DC
The inverter is overload
Recharge battery
Reduce load to 600 Watts (PINV4) , 800
Watts (PINV5) and 1000 Watts (PINV6)
maximum to maintain regulation.
SYMPTOM D: THE LOW BATTERY IS MEASURED
POSSIBLE CAUSES
SUGGESTION
The poor battery condition
Recharge battery
Inadequate power of excessive voltage drop
Check condition of battery clips and
terminals. Clean or replace as necessary
7
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS
AC output voltage (nominal)............................................................................115 Volts AC
DC input voltage range....................................................................................10-15 Volts DC
Maximum Continuous AC output power. .........................................................600 Watts (PINV4)
.........................................................................................................................800 Watts (PINV5)
.........................................................................................................................1000 Watts (PINV6)
Maximum AC output surge power ...................................................................1200 Watts (PINV4)
.........................................................................................................................1600 Watts (PINV5)
.........................................................................................................................2000 Watts (PINV6)
AC output frequency........................................................................................60 Hz +/- 2 Hz
AC output waveform........................................................................................modified sine wave
No load current draw .......................................................................................less than 0.7A (PINV4)
.........................................................................................................................less than 0.9A (PINV5)
.........................................................................................................................less than 0.9A (PINV6)
Input current.. ..................................................................................................50 - 55 AMP (PINV4)
.........................................................................................................................65 - 70 AMP (PINV5)
.........................................................................................................................80 - 85 AMP (PINV6)
Optimum efficiency ..........................................................................................90%
Ambient operating temperature range.............................................................0˚C-40˚C/32˚F-100˚F
Low battery alarm trigger point (nominal)........................................................10.5 Volts
Low battery shut down point (nominal)............................................................9.8-10.4 Volts
High battery shut down point (nominal)...........................................................15 Volts
Number of ac receptacles................................................................................2 (PINV4)/2(PINV5)/2(PINV6)
Weight..............................................................................................................1.35 kgs/2.97lbs. (PINV4)
.........................................................................................................................1.50 kgs/3.30 lbs. (PINV5)
.........................................................................................................................1.75 kgs/3.85 lbs. (PINV6)
Dimensions (W x H x D mm) ...........................................................................121x53x282 (PINV4)
.........................................................................................................................121x53x322 (PINV5)
.........................................................................................................................121x53x342 (PINV6)
Specifications are typical; individual units might vary.
Specifications are subject to change and improvement without notice.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
|