Paradyne Network Card UIM 1000T User Manual

Installation Instructions  
UIM-1000T  
Gigabit Ethernet Uplink Interface Module  
Net to Net Technologies strongly recommends the use of proper electrostatic discharge (ESD) precautions when  
handling this equipment.  
CAUTION  
1.0 INSTALLATION  
1.1 Unpack and Inspect the Equipment  
The following components should be included:  
z 1 UIM-1000T  
z 4 #6 Phillips Panhead Nylon Locking Screws  
z 2 #6 Phillips Beige Flathead Screws  
If there is visible damage, do not attempt to install the UIM-1000T; contact Customer Support at 1-  
877-638-2638 (001-603-427-0600 for international customers) or [email protected].  
1.2 Install the UIM-1000T on a Multiplexer Uplink Module (MUM2000-2)  
An uplink interface module (UIM) provides the upstream network connection, via a MUM, for Net to  
Net Technologies' IP DSLAMs; neither an IP DSLAM nor a MUM can function without a UIM.  
The MUM2000-2 is currently Net to Net's only multiplexer uplink module capable of supporting the UIM-1000T.  
NOTE  
z
Select a port on the MUM2000-2 for installation of the UIM-1000T: either port (1 or 2) may be  
used. Although not required for operational purposes, if redundancy is desired two UIMs may  
be installed on a MUM2000-2, one in each port.  
z
Remove the blanking plate from the selected port.  
Blanking plates should be stored for possible future use: if a UIM-1000T is removed from the  
MUM2000-2, it must be replaced with either another UIM or a blanking plate. DO NOT  
OPERATE THE MUM2000-2 WITH AN OPEN UIM PORT.  
CAUTION  
z
Carefully slide the faceplate of the UIM-1000T under the lip of the MUM2000-2 faceplate at  
the selected port opening such that the UIM-1000T circuit board is facedown and the label  
shows through the MUM2000-2 port opening with the UIM-1000T model name along the right-  
hand edge.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
220-0000078 rev 01  
1000Base-T RJ45 Port Pinout  
PIN CONNECTION  
1
2
3
4
5
6
7
8
TP0+  
TP0-  
TP1+  
TP2+  
TP2-  
TP1-  
TP3+  
TP3-  
3.0 ADDITIONAL INFORMATION  
3.1 LED Indications  
LED  
State  
Indication  
Additional Information  
Dplx  
solid green Full Duplex Ethernet The UIM-1000T Ethernet connection only operates  
(Duplex)  
connection is  
established  
under full duplex data transmission. As such, whenever  
an Ethernet connection is present, the Dplx LED will be  
illuminated.  
no  
no Ethernet  
If the Dplx LED is not illuminated then an Ethernet  
connection has not been established and the Lnk LED  
will remain unlit as well.  
illumination connection  
Act  
flashing  
Ethernet activity  
Traffic is flowing at 1 Gbps.  
Heavy traffic flow.  
(Activity) amber  
solid amber heavy Ethernet  
activity  
no  
no Ethernet activity  
No current traffic flow.  
illumination  
Lnk (Link) solid green 1 Gbps Ethernet  
The UIM-1000T Ethernet connection only operates  
uplink connection is under full duplex data transmission. As such, if the Lnk  
established  
LED is illuminated, the Dplx LED will also be  
illuminated.  
no  
no Ethernet  
If the Lnk LED is not illuminated then an Ethernet  
connection has not been established and the Dplx LED  
will remain unlit as well.  
illumination connection  
3.2 Regulatory Compliance for Class A Equipment  
The following regulatory compliance information applies to the UIM-1000T as mounted on a  
MUM2000-2 and installed in one of Net to Net Technologies' IP DSLAMs.  
3.2.1 US Federal Communications Commission (FCC)  
Note: This equipment has been tested and found to comply with the limits for a Class A digital  
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable  
Download from Www.Somanuals.com. All Manuals Search And Download.  
220-0000078 rev 01  
protection against harmful interference when the equipment is operated in a commercial  
environment. This equipment generates, uses and can radiate radio frequency energy and, if  
not installed and used in accordance with the instruction manual, may cause harmful  
interference to radio communications. Operation of this equipment in a residential area is  
likely to cause harmful interference in which case the user will be required to correct the  
interference at his own expense.  
Caution: Changes or modifications not expressly approved by the manufacturer could void the  
user’s authority to operate the equipment.  
3.2.2 Industry Canada  
This Class A digital apparatus complies with Canadian ICES-003.  
Cet appareil numérique de la Classe A est conforme à la norme NMB-003 du Canada.  
3.2.3 Europe  
This Class A product complies with European Norm EN55022.  
Warning: In a domestic environment this product may cause radio interference in which case  
the user may be required to take adequate measures to correct the situation.  
220-0000078 rev01  
© Copyright 2002 Net to Net Technologies, Inc.  
™ The Net to Net Logo is a trademark of Net to Net Technologies, Inc.  
Worldwide Headquarters  
Net to Net Technologies  
112 Corporate Drive  
Portsmouth, NH 03801  
USA  
EMEA Headquarters  
Net to Net Technologies  
Victoria House 19 Park Way  
Newbury Berkshire RG14 1EE  
UK  
+1 877-638-2638  
+44 (0) 1635 570950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
220-0000078 rev 01  

Milwaukee Drill 1000 1 User Manual
National Instruments Network Card NI WLS ENET 9163 User Manual
National Instruments Welding System FP AI 112 User Manual
NETGEAR Network Router RO318 User Manual
New Buck Corporation Stove FS 21 User Manual
Nokia Cell Phone X3 02 User Manual
NXP Semiconductors Network Card OM6293 User Manual
Oceanic Scuba Diving Equipment 04 8930 07 User Manual
Palm MP3 Player DAH 1500i User Manual
Panasonic Projector L6510E User Manual