Paradyne Network Card 336x E1 User Manual

ACCULINK  
336x E1 NETWORK  
TERMINATION UNIT  
OPERATOR’S GUIDE  
Document No. 3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Important Instructions  
Important Safety Instructions  
1. Read and follow all warning notices and instructions marked on the product or included in the  
manual.  
2. When an AC power source is used, this product is intended to be used with a three-wire  
grounding type plug – a plug which has a grounding pin. This is a safety feature. Equipment  
grounding is vital to ensure safe operation. Do not defeat the purpose of the grounding type  
plug by modifying the plug or using an adapter.  
Prior to installation, use an outlet tester or a voltmeter to check the ac receptacle for the  
presence of earth ground. If the receptacle is not properly grounded, the installation must not  
continue until a qualified electrician has corrected the problem.  
If a three-wire grounding type power source is not available, consult a qualified electrician to  
determine another method of grounding the equipment.  
3. Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of  
the product and to protect it from overheating, these slots and openings must not be blocked  
or covered.  
4. Do not allow anything to rest on the power cord and do not locate the product where persons  
will walk on the power cord.  
5. Do not attempt to service this product yourself, as opening or removing covers may expose  
you to dangerous high voltage points or other risks. Refer all servicing to qualified service  
personnel.  
6. General purpose cables may be provided with this product. Special cables, which may be  
required by the regulatory inspection authority for the installation site, are the responsibility  
of the customer. Use a Listed, minimum No. 26 AWG line cord for connection to the High  
bit-rate Digital Subscriber Line (HDSL) network.  
7. When installed in the final configuration, the product must comply with the applicable Safety  
Standards and regulatory requirements of the country in which it is installed. If necessary,  
consult with the appropriate regulatory agencies and inspection authorities to ensure  
compliance.  
8. A rare phenomenon can create a voltage potential between the earth grounds of two or more  
buildings. If products installed in separate buildings are interconnected, the voltage potential  
may cause a hazardous condition. Consult a qualified electrical consultant to determine  
whether or not this phenomenon exists and, if necessary, implement corrective action prior to  
interconnecting the products.  
9. Input power to the AC voltage configuration of this product must be provided by one of the  
following: (1) a UL Listed/CSA certified power source with a Class 2 or Limited Power  
Source (LPS) output for use in North America, or (2) a certified power source with a Safety  
Extra Low Voltage (SELV) output for use in the country of installation.  
Input power to the DC voltage configurations of this product must be provided by one of the  
following: (1) a National Electric Code (NEC)/Canadian Electric Code (CEC) Class 2 circuit  
for use in North America, or (2) a certified Safety Extra Low Voltage (SELV) circuit input for  
use in the country of installation.  
10. This product contains a coin cell lithium battery that is only to be replaced at the factory.  
Caution: There is a danger of explosion if the battery is incorrectly replaced. Replace only  
with the same type. Dispose of used batteries according to the battery manufacturer’s  
instructions. Attention: Il y a danger d’explosion s’il y a remplacement incorrect de la  
batterie. Remplacer uniquement avec une batterie du même type. Mettre au rebut les batteries  
usagées conformément aux instructions du fabricant.  
3360-A2-GB20-20  
December 1996  
B
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ACCULINK 336x E1 NTU  
In addition, if the equipment is to be used with telecommunications circuits, take the following  
precautions:  
Never install telephone wiring during a lightning storm.  
Never install telephone jacks in wet locations unless the jack is specifically designed for wet  
locations.  
Never touch uninsulated telephone wires or terminals unless the telephone line has been  
disconnected at the network interface.  
Use caution when installing or modifying telephone lines.  
Avoid using a telephone (other than a cordless type) during an electrical storm.  
There may be a remote risk of electric shock from lightning.  
Do not use the telephone to report a gas leak in the vicinity of the leak.  
Notices  
WARNING  
THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS A DIGITAL DEVICE,  
PURSUANT TO PART 15 OF THE FCC RULES. THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE  
PROTECTION AGAINST HARMFUL INTERFERENCE WHEN THE EQUIPMENT IS OPERATED IN A COMMERCIAL  
ENVIRONMENT. THIS EQUIPMENT GENERATES, USES, AND CAN RADIATE RADIO FREQUENCY ENERGY AND, IF  
NOT INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTION MANUAL, MAY CAUSE HARMFUL  
INTERFERENCE TO RADIO COMMUNICATIONS. OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS  
LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE  
INTERFERENCE AT HIS OWN EXPENSE.  
THE AUTHORITY TO OPERATE THIS EQUIPMENT IS CONDITIONED BY THE REQUIREMENTS THAT NO  
MODIFICATIONS WILL BE MADE TO THE EQUIPMENT UNLESS THE CHANGES OR MODIFICATIONS ARE EXPRESSLY  
APPROVED BY PARADYNE.  
WARNING  
TO USERS OF DIGITAL APPARATUS IN CANADA:  
THIS CLASS A DIGITAL APPARATUS MEETS ALL REQUIREMENTS OF THE CANADIAN INTERFERENCE-CAUSING  
EQUIPMENT REGULATIONS.  
CET APPAREIL NUMÉRIQUE DE LA CLASSE A RESPECTE TOUTES LES EXIGENCES DU RÉGLEMENT SUR LE  
MATÉRIEL BROUILLEUR DU CANADA.  
C
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Objectives and Reader Assumptions . . . . . . . . . . . . . . . . . . . . . . . . . iii  
3360-A2-GB20-20  
December 1996  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCULINK 336x E1 NTU  
Appendices  
.
.
.
.
.
.
.
.
.
.
.
.
.1.  
. B.Ć1 .  
C. Ć1.  
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. D. Ć1.  
. E.Ć1.  
. FĆ.1 .  
. G.Ć1 .  
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.HĆ.1 .  
.
.
.
.
ii  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
Objectives and Reader  
Assumptions  
This operator’s guide contains installation, operation,  
and maintenance information for the ACCULINK 336x  
E1 Network Termination Unit (NTU).  
Reference Documents  
CSA-22.2 No. 950-M89  
CSA 108-M1983  
FCC Part 15  
UL 1950  
It is assumed that you are familiar with the operation of  
digital data communication equipment and NTUs in  
particular. You should also be familiar with Simple  
Network Management Protocol (SNMP) if you want your  
E1 NTU to be managed by an SNMP manager.  
Management Information Base for Network  
Management of TCP/IP-Based Internets: MIBII.  
RFC 1213, March 1991  
Definitions of Managed Objects for the DS1 and E1  
Interface Types. RFC 1406, January 1993  
Definitions of Managed Objects for RS-232-like  
Hardware Devices. RFC 1317, April 1992  
Related Document  
7800-A2-GB20  
ACCULINK 3100 Series Open  
Management Application for  
HP OpenView Users Guide  
Extensions to the Generic-Interface MIB.  
RFC 1229, May 1991  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iii  
     
Introduction  
1
Alarm Message Capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2  
Overview  
Features  
The E1 NTU acts as an interface between a High  
bit-rate Digital Subscriber Line (HDSL) network and the  
customer’s Data Terminal Equipment (DTE), converting  
signals received from the DTE into the two binary, one  
quaternary (2B1Q) signal format for transmission over the  
HDSL network.  
The E1 NTU optimizes network performance with a  
wide range of features such as the following:  
Software configuration menu displayed via a liquid  
crystal display (LCD) to permit quick and easy  
operation, and elimination of complicated hardware  
strapping.  
The E1 NTU’s G.703 DTE interface supports  
2.048 Mbps (E1) data that is compatible with the signal  
format of ITU Recommendation G.703 and the frame  
structure of ITU Recommendation G.704.  
Local or remote configuration and operation  
flexibility.  
Several loopback capabilities and test pattern  
generators.  
In addition to the G.703 DTE interface, the 336x E1  
NTUs have one to four EIA 530A synchronous data ports  
that may be configured for rates of 64 kbps to 1984 kbps.  
G.703 DTE capability.  
Alarm message display/print capability.  
The 336x Series consists of a Model 3360 NTU  
(2-port), a Model 3364 NTU (4-port), and a Model 3365  
NTU (1-port). Differences between these models are  
discussed where applicable throughout this guide.  
Front panel emulation via Windows-based Front  
Panel Emulation software.  
Network management provided through  
industry-standard Simple Network Management  
Protocol (SNMP).  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1-1  
   
ACCULINK 336x E1 NTU  
ACCULINK 3100 Series Open Management Application  
for HP OpenView Users Guide.  
G.703 DTE Interface  
The G.703 DTE interface is compatible with the signal  
format of ITU Recommendation G.703 and the frame  
structure of ITU Recommendation G.704. This interface  
allows DTEs/PBXs to share the network with other  
high-speed equipment.  
The E1 NTU supports the following MIBs:  
MIB II – Defines the general objects for use in  
Transmission Control Protocol/Internet Protocol  
(TCP/IP) internets and provides general  
information about the E1 NTU. MIB II is  
backward-compatible with MIB I.  
Alarm Message Capability  
DS1/E1 MIB – Defines objects for managing E1  
interfaces and supports the network and G.703 DTE  
interfaces on the E1 NTU.  
The E1 NTU can be attached, either locally or  
remotely, to an ASCII terminal or printer to display or  
print alarm messages. The communications (COM) port  
can be used as the destination for Alarm Set and Alarm  
Clear messages. This enables an ASCII terminal or printer  
to monitor the E1 NTU for alarm conditions. Alarms can  
also be displayed on a PC that is using a terminal  
emulation package.  
RS-232-like MIB – Defines objects for managing  
RS-232-type interfaces (e.g., RS-422, RS-423, etc.)  
and supports synchronous data ports (PORTs 1– 4)  
and management communication ports (AUX and  
COM ports) on the E1 NTU.  
Generic-Interface Extension MIB – An extension to  
MIB II that defines additional objects for control of  
generic interfaces in MIB II. It supports control of  
tests on the G.703 DTE and synchronous data  
interfaces that are not supported by other MIBs.  
Front Panel Emulation  
The E1 NTU offers functionality through Front Panel  
Emulation software that is similar to that provided by the  
E1 NTU front panel. The E1 NTU can either be locally or  
remotely attached to a 386 or higher personal computer  
(PC) that has at least four megabytes (MB) of  
Enterprise MIB – Defines objects that are unique to  
Paradyne devices.  
random-access memory (RAM). (An external modem is  
required for remote attachment.) A copy of the E1 NTU  
front panel appears on the PC. The functionality of the  
front panel is available by clicking on the function keys  
with the mouse rather than by pressing keys from the  
actual front panel. For more information, refer to  
Two link layer protocols, Point-to-Point Protocol (PPP)  
and Serial Line Internet Protocol (SLIP), are supported for  
connection to an external SNMP manager or network  
device (e.g., a router).  
The SNMP manager or network device can be directly  
connected to the communications (COM) port. An  
external LAN Adapter can be connected to either the  
COM port or the auxiliary (AUX) port to provide Ethernet  
connectivity. Also, the E1 NTU can be daisy chained  
together by connecting the COM port of one device to the  
AUX port of the other, providing SNMP connectivity.  
SNMP Management Support  
SNMP is a network management protocol that is used  
to monitor network performance and status, and to report  
alarms (i.e., traps). To function, SNMP requires a manager  
consisting of a software program housed within a  
workstation or PC; an agent consisting of a software  
program housed within a device (e.g., the E1 NTU); and a  
Management Information Base (MIB) consisting of a  
database of managed objects.  
The SNMP management system can communicate to  
the E1 NTU remotely through the Facility Data Link  
(FDL) or (for 2-port and 4-port E1 NTUs) the  
synchronous data port’s Embedded Data Link (EDL).  
FDL provides an in-band channel for performance and  
control signals on the network interface. It uses the spare  
in time-slot zero as defined in ITU  
bit S  
a4  
Users of the external SNMP manager can issue “Get”  
and “Set” commands to an object in the SNMP database  
maintained by the E1 NTU.  
Recommendation G.704. EDL provides the ability to  
detect and synchronize on a framing pattern, provides  
cyclic redundancy checking (CRC), and maintains  
near-end and far-end performance statistics.  
The E1 NTU can be managed by any industry-standard  
SNMP manager. Paradyne provides an SNMP application  
that runs on a Hewlett-Packard HP OpenView network  
management platform. For more information, refer to the  
1-2  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
         
Introduction  
Rear Panel  
Physical Description  
The E1 NTU rear panel contains the connectors and  
switches required for the operation of the E1 NTU  
The 336x Series consists of a Model 3360 NTU  
(2-port), a Model 3364 NTU (4-port), and a Model 3365  
NTU (1-port).  
Front Panel  
One 2-line, 16-alphanumeric-character-per-line  
liquid crystal display (LCD)  
One 7-button keypad (three Function and four  
directional keys)  
Twelve light-emitting diodes (LEDs)  
Six test jacks  
LCD  
KEYPAD  
F1  
F2  
F3  
E1  
E1  
HDSL  
LINE  
Lp1  
LINE MON  
In  
In  
OK FAIL TEST SIG1 SIG2 OOF ALRM SIG OOF ALRM PDV BPV  
NETWORK DTR TXD RXD CTS RTS  
Lp2  
Out  
Out  
496-14728-01  
TEST JACKS  
LEDs  
Figure 1-1. Front Panel  
3360-A2-GB20-20  
December 1996  
1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
ACCULINK 336x E1 NTU  
G.703  
HDSL  
NETWORK  
AUX  
PORT  
COM  
PORT  
TX  
RX  
POWER  
RX SHIELD  
120  
120Ω  
IN  
OPEN  
EARTH  
OUT  
75Ω  
75Ω  
75Ω  
CAUTION: AUX PORT OR COM PORT MUST  
NOT BE CONNECTED TO HDSL NETWORK  
PORT 3  
PORT 4  
CLOCK IN  
PORT 1  
PORT 2  
495-14733  
Figure 1-2. Model 3360 Rear Panel  
G.703  
COM  
HDSL  
NETWORK  
AUX  
PORT  
TX  
RX  
POWER  
RX SHIELD  
PORT  
120Ω  
120Ω  
IN  
OPEN  
EARTH  
OUT  
75Ω  
75Ω  
75Ω  
CAUTION: AUX PORT OR COM PORT MUST  
NOT BE CONNECTED TO HDSL NETWORK  
PORT 3  
PORT 4  
CLOCK IN  
PORT 1  
PORT 2  
495-14734  
Figure 1-3. Model 3364 Rear Panel  
1-4  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Introduction  
TX  
RX  
POWER  
RX SHIELD  
PORT 1  
120Ω  
OPEN  
IN  
EARTH  
AUX  
PORT  
COM  
PORT  
OUT  
HDSL  
NETWORK  
120  
75Ω  
75Ω  
75Ω  
G.703  
495-14732  
Figure 1-4. Model 3365 Rear Panel  
Table 1-1  
Rear Panel Connectors and Switches  
Name  
Function  
POWER  
Supplies power to the E1 NTU by providing an attachment for the ac power  
module or the optional dc power cable (+24 or 48 Vdc).  
AUX PORT  
COM PORT  
Supports SNMP LAN Adapter or daisy-chain connections.  
Provides access to a locally connected PC, an ASCII terminal or printer, or an  
SNMP management link.  
HDSL NETWORK  
Provides access to the HDSL network.  
G.703—120  
Provides a 120 ohm balanced G.703 interface.  
G.703—120/75(switch)  
Selects either a 120 ohm balanced G.703 interface (the switch is IN) or a 75 ohm  
unbalanced G.703 interface (the switch is OUT).  
G.703—75TX/RX  
Provides two BNC connectors (Transmit and Receive) for a 75 ohm unbalanced  
G.703 interface.  
G.703—RX SHIELD (switch)  
Selects either an “open” or “earth” shield connection for the 75 ohm RX interface.  
(This switch must be set to “open” when using the 120 ohm interface.)  
CLOCK IN (Models 3360/3364)  
PORTs 14  
Used to attach an external clock to the E1 NTU.  
Used to connect the customer’s synchronous data DTE to the E1 NTU.  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1-5  
     
Installation  
2
The E1 NTU is connected to the customer’s equipment  
through one of the synchronous data ports (PORTs 1– 4)  
or the G.703 DTE port. It is connected to the network  
through the HDSL Network interface.  
Overview  
This chapter contains information for installing your  
E1 NTU. It includes application examples, cabling, and  
power-up information.  
The E1 NTU normally operates in conjunction with a  
Line Termination Unit (LTU) that is installed in an  
ACCULINK Access Controller (AAC).  
Application Examples  
Some common applications for the E1 NTU are:  
The E1 NTU acts as an interface between a High  
bit-rate Digital Subscriber Line (HDSL) network and the  
customer’s equipment.  
Shared access to network-based services  
NETWORK  
SERVICES  
PBX  
HDSL  
AAC  
LTU  
NTU  
LAN  
ROUTER  
496-14736-01  
Figure 2-1. Shared Access Application Example  
3360-A2-GB20-20  
December 1996  
2-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
ACCULINK 336x E1 NTU  
NETWORK  
HDSL  
HDSL  
AAC  
LTU  
AAC  
LTU  
LAN  
ROUTER  
NTU  
NTU  
LAN  
ROUTER  
496-14735-01  
Figure 2-2. Point-to-Point Application Example  
HDSL  
NTU  
FRACTIONAL  
NETWORK  
LAN  
ROUTER  
LAN  
ROUTER  
E1  
AAC  
LTU  
E1  
DSU/CSU  
DSU/CSU  
LAN  
ROUTER  
LAN  
ROUTER  
496-14737-01  
Figure 2-3. Fractional E1 Application Example  
2-2  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Installation  
Daisy chaining the COM port of one device to the  
AUX port of the other to provide SNMP  
SNMP Connection Examples  
The E1 NTU can be connected to an SNMP  
management system in a number of ways. Some examples  
include:  
Remotely managing the E1 NTU through the  
Facility Data Link (FDL) or the synchronous data  
Directly connecting the COM port to the SNMP  
Connecting the COM port to a network device (e.g.,  
NOTE  
EDL is only available on 2-port  
and 4-port E1 NTUs.  
Connecting the COM port or the AUX port to an  
external LAN Adapter for Ethernet SNMP  
LAN  
ROUTER  
SNMP  
ETHERNET  
NTU  
NETWORK  
HDSL  
AAC  
LTU  
SNMP  
PPP/SLIP  
496-14738-01  
Figure 2-4. Direct Connection to an SNMP Manager  
LAN  
ROUTER  
SNMP  
ETHERNET  
NTU  
NETWORK  
HDSL  
AAC  
LTU  
SNMP  
PPP/SLIP  
496-14739-01  
Figure 2-5. Connection through a Router to SNMP  
3360-A2-GB20-20  
December 1996  
2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
ACCULINK 336x E1 NTU  
SNMP  
NMS  
LAN  
ROUTER  
NTU  
ETHERNET  
NETWORK  
HDSL  
AAC  
LTU  
SNMP  
PPP  
LAN  
ADAPTER  
496-14740-01  
Figure 2-6. Connection through a LAN Adapter to SNMP  
NTU  
HDSL  
AAC  
SNMP  
PPP  
LTU  
NTU  
NTU  
HDSL  
HDSL  
AAC  
LTU  
NETWORK  
SNMP  
NMS  
LAN  
ROUTER  
AAC  
LTU  
SNMP  
PPP  
ETHERNET  
SNMP  
PPP  
LAN  
ADAPTER  
496-14741-01  
Figure 2-7. LAN Adapter and Daisy Chaining for SNMP Support  
LAN  
ROUTER  
NTU  
NTU  
ETHERNET  
NETWORK  
HDSL  
HDSL  
AAC  
LTU  
AAC  
LTU  
SNMP  
FDL/EDL  
SNMP  
PPP  
LAN  
ADAPTER  
496-14742-01  
Figure 2-8. Remote SNMP Management through FDL/EDL  
2-4  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Installation  
Using the optional dc power cable, the E1 NTU is  
Important Instructions  
Read and follow all warning notices and instructions  
marked on the E1 NTU or included in this guide.  
capable of operating on either a +24 Vdc power source,  
48 Vdc single source battery, or 48 Vdc redundant  
source batteries (for power backup). To select the power,  
choose one of the following power supply types.  
For a complete listing of the safety instructions, see the  
this guide.  
Installing the +24 Vdc Power Supply  
To install the E1 NTU using a +24 Vdc power supply,  
HANDLING PRECAUTIONS  
FOR  
STATIC-SENSITIVE DEVICES  
To install the +24 Vdc power supply,  
This product is designed to protect  
sensitive components from damage  
due to electrostatic discharge (ESD)  
during normal operation. When  
performing installation procedures,  
however, take proper static control  
precautions to prevent damage to  
equipment. If you are not sure of the  
proper static control precautions,  
contact your nearest sales or service  
representative.  
1. Connect the green wire to a suitable earth ground.  
2. Connect the white wire to the +24 Vdc return.  
3. Connect the orange wire to the +24 Vdc source.  
4. Cut the black, red and blue wires off at the outer  
insulation.  
5. Plug the power connector into the E1 NTU.  
Optional Power Sources  
The E1 NTU is typically powered by the ac power  
module. Use the following procedures only if you want  
to use an optional dc power source.  
NTU POWER  
PLUG  
TO CUSTOMER-SUPPLIED BATTERY  
BLACK  
1
X
RED  
2
X
GREEN  
3
EARTH GROUND  
+24 VDC RETURN  
+24 VDC SOURCE  
WHITE  
4
ORANGE  
5
BLUE  
6
X
CABLE NUMBER 3100-F1-520  
495-14743  
Figure 2-9. +24 Vdc Power Supply Pinouts  
3360-A2-GB20-20  
December 1996  
2-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
ACCULINK 336x E1 NTU  
2. Connect the green wire to a suitable earth ground.  
Installing the Single –ā48 Vdc Power Supply  
To install the E1 NTU using a single source 48 Vdc  
procedure.  
3. Connect the orange and blue wires to the –ā48 Vdc  
input source.  
4. Cut the white wire off at the outer insulation.  
5. Plug the power connector into the E1 NTU.  
To install the 48 Vdc single source power supply,  
1. Connect the black and red wires to the 48 Vdc  
return source.  
NTU POWER  
PLUG  
TO CUSTOMER-SUPPLIED BATTERY  
BLACK  
1
48 VDC RETURN  
EARTH GROUND  
RED  
2
GREEN  
3
WHITE  
4
X
ORANGE  
5
48 VDC INPUT  
BLUE  
6
CABLE NUMBER 3100-F1-520  
495-14744  
Figure 2-10. ā48 Vdc Single Source Power Supply Pinouts  
2-6  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installation  
3. Connect the green wire to a suitable earth ground.  
Installing the Redundant –ā48 Vdc Power  
Supply  
4. Connect the orange wire to the 48 Vdc input  
source B.  
To install the E1 NTU using a redundant 48 Vdc  
procedure.  
5. Connect the blue wire to the 48 Vdc input  
source A.  
To install the redundant 48 Vdc power supply,  
6. Cut the white wire off at the outer insulation.  
7. Plug the power connector into the E1 NTU.  
1. Connect the black wire to the 48 Vdc return  
source B.  
2. Connect the red wire to the 48 Vdc return  
source A.  
NTU POWER  
PLUG  
TO CUSTOMER-SUPPLIED BATTERY  
BLACK  
1
48 VDC RETURN B  
48 VDC RETURN A  
EARTH GROUND  
RED  
2
GREEN  
3
WHITE  
4
X
ORANGE  
5
48 VDC INPUT B  
48 VDC INPUT A  
BLUE  
6
CABLE NUMBER 3100-F1-520  
495-14745  
Figure 2-11. ā48 Vdc Redundant Source Power Supply Pinouts  
3360-A2-GB20-20  
December 1996  
2-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
ACCULINK 336x E1 NTU  
Cabling Examples  
NOTE  
The E1 NTU is supplied with an ac power module.  
The 120/75switch selects  
either the 120 ohm balanced  
G.703 interface or the 75 ohm  
unbalanced G.703 interface. The  
RX SHIELD switch selects either  
an “open” or “earth” shield  
Optional cables that you can order from the company  
connection for the 75 ohm RX  
interface. (This switch must be set  
to “open” when using the 120 ohm  
interface.)  
HDSL  
HDSL  
NETWORK  
HDSL  
NETWORK  
HDSL  
COM PORT  
NETWORK  
COM PORT  
G.703  
G.703  
HDSL  
NETWORK  
HDSL  
NETWORK  
AUX  
PORT  
COM  
PORT  
AUX  
PORT  
COM  
PORT  
POWER  
POWER  
TX  
RX  
TX  
RX  
RX SHIELD  
OPEN  
RX SHIELD  
120  
120Ω  
120Ω  
IN  
OPEN 120Ω  
IN  
EARTH  
EARTH  
OUT  
OUT  
75Ω  
75Ω  
75Ω  
75Ω  
CAUTION: AUX PORT OR COM PORT MUST  
NOT BE CONNECTED TO HDSL NETWORK  
CAUTION: AUX PORT OR COM PORT MUST  
NOT BE CONNECTED TO HDSL NETWORK  
75Ω  
75Ω  
PORT  
PORT  
3
1
PORT  
4
PORT  
PORT  
3
1
PORT  
4
NTU  
NTU  
CLOCK IN  
PORT  
2
CLOCK IN  
PORT  
2
SERIAL  
PORT  
TO DC  
POWER  
3100-F1-520  
(OPTIONAL)  
TO AC  
POWER  
MODULE  
3100-F1-540  
SNMP  
MANAGER  
NOTE:  
3100 SERIES  
OR  
FRONT PANEL  
EMULATION  
SOFTWARE,  
3100-C1-010  
495-14746  
Figure 2-12. Cabling Examples  
2-8  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Installation  
If the self-test fails, the Failed screen appears for  
five seconds. The Fail LED lights, and an  
Power-Up Self-Test  
eight-digit failure code (xxxxxxxx) is displayed for  
use by service personnel to determine the cause of  
the self-test failure. The E1 NTU continues to try  
to operate. If you are in doubt about the results of  
the self-test, use the Self-Test Health command to  
Health section in Chapter 4, Maintenance).  
After you connect the E1 NTU to a power source, the  
unit performs the power-up self-test to ensure that it is in  
good working order. The E1 NTU performs this test on  
itself upon power-up or after a device reset, unless it has  
been disabled by the Self-Test configuration option (see  
The self-test includes a basic processor test, a limited  
memory test, a code checksum test, and basic verification  
tests of the internal components. The front panel LCD  
displays the progress and pass/fail status of these  
power-up tests.  
Self-Test:  
Failed xxxxxxxx  
F3  
F1  
F2  
The power-up self-test consists of the following steps:  
1. Once the E1 NTU is plugged in, the In Progress  
screen appears and the Fail LED blinks ON and  
Off continuously.  
OK FAIL TEST SIG1 SIG2 OOF ALRM SIG OOF ALRM PDV BPV  
NETWORK DTR TXD RXD CTS RTS  
495-14747  
4. The top-level menu screen appears.  
Self-Test:  
In Progress  
E1 HDSL NTU  
F3  
F1  
F2  
Stat  
Test  
Cnfig  
OK FAIL TEST SIG1 SIG2 OOF ALRM SIG OOF ALRM PDV BPV  
NETWORK DTR TXD RXD CTS RTS  
F3  
F1  
F2  
495-14747  
OK FAIL TEST SIG1 SIG2 OOF ALRM SIG OOF ALRM PDV BPV  
NETWORK DTR TXD RXD CTS RTS  
2. All the LEDs then start to flash simultaneously in  
the pattern twice ON, then Off. Then, the LCD  
begins to flash characters and numbers in the same  
pattern, alternating with the flashing LEDs.  
495-14749  
3. If the self-test is successful, the Passed screen  
appears for one second, the Fail LED turns Off  
and the OK LED lights.  
Self-Test:  
Passed  
F3  
F1  
F2  
OK FAIL TEST SIG1 SIG2 OOF ALRM SIG OOF ALRM PDV BPV  
NETWORK DTR TXD RXD CTS RTS  
495-14748  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2-9  
   
Operation  
3
Configuring for Network Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-34  
3360-A2-GB20-20  
December 1996  
3-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ACCULINK 336x E1 NTU  
Overview  
Using the Front Panel  
This chapter contains information for operating your  
E1 NTU. It includes a description of the front panel and  
sample procedures for configuring the E1 NTU.  
LCD, a keypad, test jacks, and 12 LEDs.  
NOTE  
You can display a graphical  
representation of the E1 NTU  
front panel on an attached PC  
LCD  
KEYPAD  
F1  
F2  
F3  
E1  
E1  
HDSL  
LINE  
Lp1  
LINE MON  
In  
In  
OK FAIL TEST SIG1 SIG2 OOF ALRM SIG OOF ALRM PDV BPV  
NETWORK DTR TXD RXD CTS RTS  
Lp2  
Out  
Out  
496-14728-01  
TEST JACKS  
LEDs  
Figure 3-1. E1 NTU Front Panel  
3-2  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Operation  
LCD  
Keypad  
navigate through the menu tree and select choices  
presented on the second line of the LCD.  
Messages such as alarms, command/test  
completion, and action in progress  
Front panel menu tree information (see  
F3  
F1  
F2  
Figure 3-3. Keypad  
F3  
F1  
F2  
Use the  
key to move up the menu.  
Figure 3-2. LCD  
The LCD displays status messages as requested via the  
Device Health and Status branch of the front panel menu  
Maintenance). In addition, the highest level status  
message appears on the front panel automatically if no  
front panel action has occurred at the E1 NTU for the past  
five minutes.  
F3  
F1  
F2  
Use the  
key to exit any part of the menu in which  
you may be operating. You immediately return to the  
top-level menu screen shown on the front panel menu (see  
The LCD also lists commands, configuration options,  
and test results. In most cases, the top line shows the  
command or option name and default value, while the  
second line displays options and responses. When a  
response is required, select from the options displayed  
directly above the Function keys (F1, F2, F3); make your  
choice by pressing the corresponding Function key.  
F3  
F1  
F2  
Use the Function (F1, F2, F3) keys to make selections  
from the choices presented on the second line of the LCD.  
When this line presents choices, it is generally divided  
into three sections, each displayed directly above one of  
the Function keys. When your choice appears above one  
of the Function keys, press that key to select that choice.  
F3  
F1  
F2  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-3  
       
ACCULINK 336x E1 NTU  
The scroll keys ( and ) serve one of two functions,  
depending on whether a menu screen or a data entry  
screen appears on the front panel.  
LEDs  
There are twelve LEDs on the E1 NTU front panel.  
between the G.703 DTE port and the data ports. Refer to  
the Selecting the G.703 DTE or Data Port for LED  
status the LEDs display.  
For data entry screens, the  
character to the left while the  
character to the right.  
key scrolls one  
key scrolls one  
For menu screens, the  
key scrolls to the previous  
menu choice while the  
choice.  
key scrolls to the next menu  
OK FAIL TEST SIG1 SIG2 OOF ALRM SIG OOF ALRM PDV BPV  
If a choice is available to the left of the screen, the  
character appears on the top line. If a choice is  
available to the right of the screen, the character  
appears on the top line. If choices are available to both the  
right and the left of the screen, two arrows appear ( ).  
The arrows indicate that you must use the scroll keys to  
bring the additional options onto the screen.  
NETWORK  
DTR TXD RXD CTS RTS  
495-14749  
Figure 3-5. E1 NTU LEDs  
A green LED indicates normal operation. A yellow  
LED indicates a warning (for the G.703 DTE port) or  
activity (for the data ports). Conditions are sampled every  
tenth of a second.  
The twelve front panel LEDs are grouped into four  
sections to indicate the status of the:  
F3  
F1  
F2  
Test Jacks  
Six test jacks are located on the front panel  
in Chapter 4, Maintenance.  
HDSL  
NET  
E1  
E1  
LINE MON  
Lp1  
In  
In  
Lp2  
Out  
Out  
495-14753  
Figure 3-4. Test Jacks  
3-4  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
       
Operation  
Table 3-1  
System LEDs  
Name  
Color  
Meaning  
OK  
Green  
Indicates the current operational state of the E1 NTU.  
ON:  
The E1 NTU is operational and has power.  
OFF:  
The E1 NTU is performing a power-up self-test or a system failure  
has occurred.  
BLINKING:  
A software download is in progress.  
FAIL  
Yellow  
Yellow  
Indicates a system failure or a self-test.  
ON:  
A device error/fault is detected or a reset has just occurred.  
OFF:  
No system failures are detected.  
A self-test is in progress.  
BLINKING:  
TEST  
A system test is in progress.  
ON:  
A loopback or pattern test has been initiated either locally, by the  
network, or externally.  
OFF:  
No tests are active.  
Table 3-2  
Network Interface LEDs  
Name  
Color  
Meaning  
SIG1  
SIG2  
OOF  
Green  
Green  
Yellow  
Yellow  
Monitors the signal being received from the network.  
ON:  
A recoverable signal is being received from the network on loop 1.  
OFF:  
The signal cannot be recovered from the network on loop 1 (a Loss  
of Signal condition exists).  
Monitors the signal being received from the network.  
ON:  
A recoverable signal is being received from the network on loop 2.  
OFF:  
The signal cannot be recovered from the network on loop 2 (a Loss  
of Signal condition exists).  
Monitors Out Of Frame (OOF) conditions on the received network signal.  
ON:  
At least one OOF was detected on the signal during the sampling  
period.  
OFF:  
No OOFs were detected on the signal during the sampling period.  
ALRM  
Indicates whether an alarm condition exists on the received network signal.  
ON:  
An alarm condition (LOS, LOF, EER, RAI, AIS, RMA, MFA) exists on  
the received network signal. Use the Device Health and Status  
command to determine the alarm type.  
OFF:  
No alarm condition exists on the network interface signal.  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-5  
     
ACCULINK 336x E1 NTU  
Table 3-3  
G.703 DTE Port LEDs  
Name  
Color  
Meaning  
SIG  
Green  
Yellow  
Yellow  
Monitors the signal being received from the G.703 DTE port.  
ON:  
A recoverable signal is being received from the G.703 DTE port.  
OFF:  
The signal cannot be recovered from the G.703 DTE port (a Loss of  
Signal condition exists).  
OOF  
Monitors Out Of Frame (OOF) conditions on the received G.703 DTE signal.  
ON:  
At least one OOF was detected on the signal during the sampling  
period.  
OFF:  
No OOFs were detected on the signal during the sampling period.  
ALRM  
Indicates whether an alarm condition exists on the received G.703 DTE signal.  
ON:  
An alarm condition (LOS, LOF, EER, RAI, AIS, RMA, MFA) exists on  
the received G.703 DTE signal. Use the Device Health and Status  
command to determine the alarm type.  
OFF:  
No alarm condition exists on the G.703 DTE Interface signal.  
PDV  
BPV  
Yellow  
Yellow  
Monitors Pulse Density Violations (PDV) on the received G.703 DTE signal.  
ON:  
At least one PDV was detected (and corrected) on the received  
G.703 DTE signal during the sampling period.  
OFF:  
No PDVs were detected on the received G.703 DTE signal during  
the sampling period.  
Monitors Bipolar Violations (BPV) on the received G.703 DTE signal.  
ON:  
At least one BPV was detected (and corrected) on the received  
G.703 DTE signal during the sampling period.  
OFF:  
No BPVs were detected on the received G.703 DTE signal during  
the sampling period.  
3-6  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
   
Operation  
Table 3-4  
Data Port LEDs  
Name  
Color  
Meaning  
DTR  
Green  
Monitors the state of interchange circuit CD (CCITT 108/1, /2) – Data Terminal Ready  
received from the synchronous data DTE.  
ON:  
DTR is being asserted by the synchronous data DTE.  
DTR is not being asserted.  
OFF:  
TXD  
RXD  
Yellow  
Yellow  
Monitors activity on interchange circuit BA (CCITT 103) – Transmitted Data. This is the  
data sent from the synchronous data DTE to the data port on the E1 NTU.  
ON:  
Ones are being received from the synchronous data DTE.  
Zeros are being received from the synchronous data DTE.  
OFF:  
CYCLING:  
Both ones and zeros are being received from the synchronous  
data DTE.  
Monitors activity on interchange circuit BB (CCITT 104) – Received Data. This is data  
sent to the synchronous data DTE from the data port on the E1 NTU.  
ON:  
Ones are being sent to the synchronous data DTE.  
OFF:  
Zeros are being sent to the synchronous data DTE.  
Both ones and zeros are being sent to the synchronous data DTE.  
CYCLING:  
CTS  
RTS  
Yellow  
Yellow  
Monitors the state of interchange circuit CB (CCITT 106) – Clear-to-Send sent to the  
synchronous data DTE.  
ON:  
CTS is being asserted by the E1 NTU.  
CTS is not being asserted.  
OFF:  
Monitors the state of interchange circuit CA (CCITT 105) – Request-to-Send received  
from the synchronous data DTE.  
ON:  
RTS is being asserted by the synchronous data DTE.  
RTS is not being asserted.  
OFF:  
3360-A2-GB20-20  
December 1996  
3-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
ACCULINK 336x E1 NTU  
4. The following screens appear in the order listed  
Displaying Unit Identity  
each time you press the  
key.  
The identity of the E1 NTU (serial number, model  
number, software revision level, hardware revision level,  
and customer identification) is available through the  
Status branch of the front panel menu (see Appendix A,  
Identity:  
Ser=xxxxxxx  
F3  
F3  
F3  
F3  
F3  
F3  
F3  
F1  
F2  
The customer identification is the only identity number  
you can change.  
To display the E1 NTU’s identity (ID),  
Identity:  
Mod=xxxx-xx-xxx  
1. From the top-level menu screen, select Stat.  
F1  
F2  
E1 HDSL NTU  
Stat  
Test  
Cnfig  
F3  
Identity:  
Cust ID=xxxxxxxx  
F1  
F2  
F1  
F2  
2. From the Status screen, press the  
ID selection appears on the screen.  
key until the  
Identity:  
SRev=xx.xx.xx  
Status:  
HDSL DevHS STest  
F1  
F2  
F3  
F1  
F2  
Identity:  
CCA1=xxxx-xxx  
3. Select ID.  
Status:  
TStat  
F1  
F2  
LED  
ID  
F3  
F1  
F2  
Identity:  
CCA2=xxxx-xxx  
F1  
F2  
Identity:  
CCA3=xxxx-xxx  
F1  
F2  
3-8  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
   
Operation  
To change the customer identification (CID),  
4. Select CID.  
1. From the top-level menu, press the  
the Ctrl selection appears on the screen.  
key until  
Control:  
Reset CID  
DL  
E1 HDSL NTU  
F3  
F1  
F2  
Stat  
Test  
Cnfig  
F3  
F1  
F2  
5. Use the  
and  
keys to position the cursor  
under the desired character. You must enter a  
character before the  
moves the cursor to the  
next space to the right.  
2. Select Ctrl.  
CustID:xxxxxxxx  
E1 HDSL NTU  
Cnfig Ctrl  
Up  
Down Save  
Test  
F3  
F1  
F2  
F3  
F1  
F2  
6. Enter the desired ID. Press F1 (Up) and F2  
(Down) to scroll up and down through the valid  
characters/numbers for the customer ID. Valid  
characters are 0 through 9, #, -, ., /, A to Z, and  
blank space. Press F3 (Save) to save the ID.  
3. From the Control screen, press the  
key until  
the CID selection appears on the screen.  
Control:  
Rel  
LED ClrReg  
CustID:xxxxxxxx  
F3  
F1  
F2  
Up  
Down Save  
F3  
F1  
F2  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-9  
 
ACCULINK 336x E1 NTU  
4. From the Select LEDs screen, press the Function  
key that corresponds to E1 or the port for which  
you want to display LEDs. Use the scroll keys, if  
necessary.  
Displaying LED Conditions  
The same conditions monitored by the front panel  
LEDs can also be monitored by the LED command. This  
command is most useful when the E1 NTU is being  
Emulation). When using Front Panel Emulation, no LEDs  
are shown on the PC’s screen; you must use the Stat  
command procedure described below to get LED  
information.  
Select LEDs:  
E1  
Prt1  
Prt2  
F3  
F1  
F2  
NOTE  
If you chose E1, the LED Display screen lists the  
LED signals, two at a time, on the second line. A  
vertical bar at the left of the LED name indicates  
the condition is ON, while an underscore indicates  
the condition is Off.  
The following procedure is an  
example only. Screen displays  
may vary depending on the  
model of the E1 NTU.  
LED Display:  
_Test _NetSig1  
To display LED conditions on the front panel screen,  
1. From the top-level menu screen, select Stat.  
F3  
F1  
F2  
E1 HDSL NTU  
If you chose a port, the Port n LEDs screen lists  
the LED signals, two at a time, on the second line.  
A vertical bar at the left of the LED name  
indicates the condition is ON, while an underscore  
indicates the condition is Off.  
Stat  
Test  
Cnfig  
F3  
F1  
F2  
2. From the Status screen, press the  
LED selection appears on the screen.  
key until the  
Port n LEDs:  
_DTR _TXD  
Status:  
F3  
F1  
F2  
HDSL DevHS STest  
F3  
F1  
F2  
5. Use the  
and  
keys to scroll LED names  
onto the screen.  
3. From the Status screen, select LED.  
Status:  
Perf  
TStat LED  
F3  
F1  
F2  
3-10  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
   
Operation  
The currently selected port name appears on the  
top line of the LCD. DTE indicates the G.703  
DTE port.  
Selecting the G.703 DTE or  
Data Port for LED Display  
Use the LED command on the Control branch to select  
which port’s (G.703 DTE or data port) status appears on  
the five shared LEDs on the front panel.  
LED Dsply: DTE  
DTE  
Prt1  
Prt2  
F3  
F1  
F2  
NOTE  
The following procedure is an  
example only. Screen displays  
may vary depending on the  
model and configuration of the  
E1 NTU.  
4. From the LED Dsply screen, press the Function  
key that corresponds to the G.703 DTE or data  
port for which you want the LEDs to display. Use  
the scroll keys, if necessary.  
Select DTE to monitor the G.703 DTE port’s SIG,  
OOF, ALRM, PDV, and BPV status signals on the  
shared LEDs.  
To select a port for LED display,  
1. From the top-level menu screen, press the  
until the Ctrl selection appears on the screen.  
key  
Select a particular data port to monitor the data  
port’s DTR, TXD, RXD, CTS, and RTS control  
signals on the shared LEDs.  
E1 HDSL NTU  
Stat  
Test  
Cnfig  
Changing Configuration  
Options  
F3  
F1  
F2  
The E1 NTU is an intelligent device that displays only  
valid options for the current configuration. Therefore, you  
are only presented with menu choices that are consistent  
with the current configuration and operational state of the  
E1 NTU; invalid combinations of configuration options  
do not appear. For example, menus displayed for the  
Model 3360 (2 ports) and the Model 3364 (4 ports) differ  
due to the number of ports available. Also, if the G.703  
DTE interface selection is disabled, many of the menu  
choices do not appear. Be aware that although all options  
are shown in this guide, what you see on your E1 NTU  
varies with your configuration.  
2. Select Ctrl.  
E1 HDSL NTU  
Test Cnfig Ctrl  
F3  
F1  
F2  
3. From the Control screen, select LED.  
The E1 NTU offers four sets of configuration options  
located in the following memory areas:  
Control:  
Active (Activ). The configuration option set active  
for the E1 NTU is stored here. Before a  
Rel  
LED ClrReg  
configuration option set becomes active for the E1  
NTU, you must save the set to the Active area.  
When the E1 NTU is shipped from the factory, the  
Active configuration option set is identical to the  
Factory set. This area can be written to and controls  
the current operation of the device.  
F3  
F1  
F2  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-11  
     
ACCULINK 336x E1 NTU  
Customer 1 (Cust1). The first of two sets of  
customer-defined configuration options. This area  
can be written to.  
2. Select the configuration option set to be copied  
into the Edit area by using the appropriate  
Function key. Use the scroll keys, if necessary.  
Customer 2 (Cust2). The second of two sets of  
customer-defined configuration options. This area  
can be written to.  
Load from:  
Activ Cust1  
Factory (Fact). This is a set of configuration  
options preset at the company. This set is  
determined by what is considered to be the most  
common configuration used in the E1 NTU market.  
Factory options are read-only.  
F3  
F1  
F2  
3. Select Edit.  
The configuration options are divided into functional  
groups. Appendix C contains a list of the configuration  
options and defaults. These groups are:  
Choose Funct:  
Edit  
Save  
DTE (G.703) Interface  
Port  
F3  
F1  
F2  
Network Interface  
Channel  
4. From the Edit screen, select the functional group  
you want to edit by pressing the appropriate  
Function key. Use the scroll keys, if necessary.  
(The NET selection is shown as an example only.)  
General  
User Interface  
Alarm  
Edit:  
General SNMP  
SNMP Trap  
DTE  
Port  
NET  
F3  
F1  
F2  
Use the Configuration (Cnfig) branch of the front panel  
menu tree to display or change E1 NTU configuration  
The configuration options for the selected  
functional group appear on the front panel one  
option at a time. The option name appears on  
Line 1 with the current value next to it. To reach  
other options, use the Next and Previous selections  
to scroll forward and backward through the group  
of options.  
Displaying/Editing Configuration Options  
To display/edit configuration options,  
1. From the top-level menu screen, select Cnfig.  
HDSL Mode:NTU  
E1 HDSL NTU  
Next  
NTU  
LTU  
Stat  
Test  
Cnfig  
F3  
F1  
F2  
F3  
F1  
F2  
5. Press the appropriate Function key to choose  
another value. Use the scroll keys, if necessary.  
6. Use the Save procedure to save your changes to  
the Active or Customer area.  
3-12  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
   
Operation  
Saving Edit Changes  
Selecting/Copying to a Specific Port  
Save edit changes to the Active area when you want  
those changes to take effect immediately. Save edit  
changes to the Customer area when you want to overwrite  
the existing Customer configuration options and store  
these changes for future use.  
For the E1 NTU, you have the capability of selecting a  
specific port to configure, and then (for 2-port and 4-port  
E1 NTUs) copying the configuration options from that  
port to another port (or to all ports).  
NOTE  
NOTE  
The following procedure is an  
example only. Screen displays  
may vary depending on the  
model and configuration of the  
E1 NTU.  
If you attempt to exit the Edit  
function after making changes  
without performing a Save, the E1  
NTU prompts you with Save  
Options? Choose Yes or No.  
To select a specific port to configure,  
To save edit changes,  
1. From the top-level menu screen, select Cnfig.  
1. From the Choose Function screen (one level above  
the Edit screen, two levels below the top-level  
menu screen), select Save.  
2. Select the configuration option set to be copied  
into the Edit area by using the appropriate  
Function key. Use the scroll keys, if necessary.  
Choose Funct:  
3. Select Edit.  
Edit  
Save  
4. From the Edit screen, select Port.  
F3  
F1  
F2  
Edit:  
DTE  
Port  
NET  
2. Choose whether you want to save to the Active,  
Customer 1, or Customer 2 area. Use the scroll  
keys, if necessary.  
F3  
F1  
F2  
Save Edit to:  
Activ Cust1  
5. From the Port Select screen, press the Function  
key that corresponds to the port you want to  
configure. Use the  
onto the screen, if necessary. Configure the port  
key to scroll addition ports  
F3  
F1  
F2  
Port Select:  
Copy Prt1  
Prt2  
F3  
F1  
F2  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-13  
 
ACCULINK 336x E1 NTU  
To copy the configuration options to one or all ports,  
6. From the Port Select screen, select Copy.  
Specify the two community names that are allowed  
to access the device’s Management Information  
Base (MIB).  
Configure the device to send traps to the SNMP  
manager, if desired.  
Port Select:  
Copy Prt1  
Prt2  
Selecting the Port  
F3  
F1  
F2  
The SNMP manager or network device (e.g., a router)  
can be directly connected to the communications (COM)  
port. An external LAN Adapter can be connected to either  
the COM port or the auxiliary (AUX) port to provide  
Ethernet or Token Ring connectivity. Also, the E1 NTU  
can be daisy chained together by connecting the COM  
port of one device to the AUX port of the other, providing  
SNMP connectivity.  
7. Select the port from which you want to copy the  
configuration options using the corresponding  
Function key.  
Copy From:  
Prt1  
Prt2  
Prt3  
The COM port can support either synchronous or  
asynchronous PPP, or asynchronous SLIP at data rates of  
up to 38,400 bps. The AUX port can support data rates up  
to 38,400 bps.  
F3  
F1  
F2  
The example shown below assumes that the COM port  
is being used as the link to the SNMP manager.  
8. Select the port to which you want to copy the  
configuration options using the corresponding  
Function key. Or, press F1 (All) to choose to copy  
to all ports.  
To select the COM port as the management link,  
1. From the top-level menu screen, select Cnfig.  
2. Select the configuration option set to be copied  
into the Edit area by using the appropriate  
Copy To:  
All  
Prt1  
Prt2  
Function key. Use the scroll keys, if necessary.  
F3  
F1  
F2  
3. Select Edit.  
4. From the Edit screen, press the  
key until the  
User selection appears on the screen.  
Configuring the E1 NTU for  
SNMP Management  
5. Select User.  
To configure the E1 NTU for management by an  
SNMP management system you must,  
Edit:  
Chan Gen  
User  
Select and configure the port that provides the link  
to the SNMP management system.  
F3  
F1  
F2  
Set the Internet Protocol (IP) address and subnet  
mask needed to access the device (see Appendix F,  
6. Press F1 (Next) until the Com Use configuration  
option appears.  
Select the link layer protocol (PPP or SLIP) for the  
port.  
3-14  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
       
Operation  
7. Select SNMP to configure the COM port as the  
management link to an external SNMP manager.  
6. From the SNMP Config screen, select Gen.  
SNMP Config:  
Com Use:  
Gen  
Trap  
Next SNMP ASCII  
F3  
F1  
F2  
F3  
F1  
F2  
7. Press F1 (Next) until the Com IP Adr  
configuration option appears.  
Setting the IP Address  
The IP address is the address used by the SNMP  
manager to access the device. For devices using PPP, the  
IP address can be negotiated if the network device (e.g.,  
router or SNMP manager) supports such negotiation. The  
IP address is composed of four fields with three digits per  
field (xxx.xxx.xxx.xxx).  
NOTE  
Steps 8 and 9 describe the  
process for entering the Com IP  
address. This process applies to  
any IP address.  
The IP address is set for the COM port or the AUX  
port (with LAN Adapter or daisy chain), depending on  
which one has been chosen as the SNMP communications  
link. The example below assumes that an IP address of  
010.155.111.222 is being set for the COM port. You can  
use the same principles to assign any value (between 000  
and 255 for each digit field) to either port.  
8. Press F2 (Edit) to edit the IP address. You have the  
option of using F3 (Clear) to reset the IP address  
to the factory default 000.000.000.000.  
Com IP Adr:  
Next Edit  
To assign an IP address to the COM port,  
Clear  
1. From the top-level menu screen, select Cnfig.  
F3  
F1  
F2  
2. Select the configuration option set to be copied  
into the Edit area by using the appropriate  
Function key. Use the scroll keys, if necessary.  
9. Use the  
and  
keys to position the cursor  
under the digit you want to change. Press F1 (Up)  
to increment the digit or F2 (Down) to decrement  
the digit. In this example, you would press  
once to place the cursor under the middle digit in  
the first digit field, then press F1 (Up) once to  
change the 0 to a 1. Continue in this manner to  
change the other digits.  
3. Select Edit.  
4. From the Edit screen, press the  
key until the  
SNMP selection appears on the screen.  
5. Select SNMP.  
000.000.000.000  
Edit:  
Up  
Down Save  
User Alarm SNMP  
F3  
F1  
F2  
F3  
F1  
F2  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-15  
   
ACCULINK 336x E1 NTU  
10. When you are through changing the IP address,  
you must press F3 (Save) to save the value.  
Otherwise, the original value will be retained.  
To select the link layer protocol,  
1. From the top-level menu screen, select Cnfig.  
2. Select the configuration option set to be copied  
into the Edit area by using the appropriate  
010.155.111.222  
Up  
Down Save  
Function key. Use the scroll keys, if necessary.  
F3  
F1  
F2  
3. Select Edit.  
4. From the Edit screen, press the  
key until the  
SNMP selection appears on the screen.  
Selecting the Link Layer Protocol  
5. Select SNMP.  
Two link layer protocols, Point-to-Point Protocol (PPP)  
and Serial Line Internet Protocol (SLIP), are supported for  
connection to an external SNMP manager or network  
device (e.g., a router). PPP can be used for synchronous or  
asynchronous operation. SLIP can be used for  
Edit:  
User Alarm SNMP  
asynchronous operation only.  
F3  
F1  
F2  
The E1 NTU implementation of PPP supports the  
following:  
6. From the SNMP Config screen, select Gen.  
Full negotiation of PPP’s Link Control Protocol  
(LCP).  
Active negotiation of LCP when the connection is  
established.  
SNMP Config:  
Gen  
Trap  
Maximum Request Unit (MRU) sizes up to  
1500 bytes, but the E1 NTU will attempt to  
negotiate down to 500 bytes.  
F3  
F1  
F2  
The E1 NTU provides a unique LCP magic number  
derived from the unit serial number and the elapsed  
time.  
7. Press F1 (Next) until the Com Link configuration  
option appears.  
Full negotiation of escape characters.  
8. Press F2 (PPP) or F3 (SLIP).  
The E1 NTU implementation of PPP does not support  
Link Quality Reports (LQR), compression, encryption,  
Password Authentication Protocol (PAP) or Challenge  
Authentication Protocol (CHAP).  
Com Link:  
Next PPP  
SLIP  
The E1 NTU implementation of SLIP supports a fixed  
MRU size of 1006 bytes.  
F3  
F1  
F2  
Before selecting the protocol, you must first select the  
port to be used as the communications link. Refer to the  
assumes that the COM port is being used as the  
communications link.  
3-16  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Operation  
8. Press F2 (Edit) to edit the community name. The  
Specifying the Community Name(s) and  
Access Type(s)  
factory default community name is public.  
You have the capability of specifying up to two  
community names (community name 1 and community  
name 2) to be used by external SNMP managers when  
trying to access objects in the E1 NTU’s MIB. Once you  
specify the community name(s), you must then specify the  
type of access to the MIB that SNMP managers in the  
community are permitted to have.  
CommunityName1:  
Next Edit  
Clear  
F3  
F1  
F2  
To specify the community name 1 and its access type,  
1. From the top-level menu screen, select Cnfig.  
NOTE  
Steps 9 and 10 describe the  
process for entering text strings  
for SNMP configuration options.  
This process applies to entering  
any text strings into SNMP  
configuration options.  
2. Select the configuration option set to be copied  
into the Edit area by using the appropriate  
Function key. Use the scroll keys, if necessary.  
3. Select Edit.  
4. From the Edit screen, press the  
key until the  
SNMP selection appears on the screen.  
9. Use the  
and  
keys to position the cursor  
under the character you want to change. Press  
F1 (Up) or F2 (Down) to scroll through the valid  
numbers/characters for the text string.  
5. Select SNMP.  
Edit:  
User Alarm SNMP  
public  
Up  
Down Save  
F3  
F1  
F2  
F3  
F1  
F2  
6. From the SNMP Config screen, select Gen.  
The F1 (Up) key scrolls through the ASCII  
character set in the following order: numbers  
(09), lowercase letters (a–z), uppercase letters  
(A–Z), space character, ASCII symbols (ascending  
order, based on ASCII code), and the End of Line  
symbol (). The erases all characters to the  
right of the cursor.  
SNMP Config:  
Gen  
Trap  
F3  
F1  
F2  
10. When you are through changing the community  
name, you must press F3 (Save) to save the value.  
Otherwise, the original value will be retained.  
7. Press F1 (Next) until the CommunityName1  
configuration option appears.  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-17  
 
ACCULINK 336x E1 NTU  
11. Press F1 (Next) until the Access 1 configuration  
option appears.  
Enabling SNMP Trap Messages  
To enable SNMP trap messages from this device,  
12. Press F2 (Read) or F3 (R/W).  
1. From the top-level menu screen, select Cnfig.  
2. Select the configuration option set to be copied  
into the Edit area by using the appropriate  
Access 1:  
Next Read R/W  
Function key. Use the scroll keys, if necessary.  
F3  
F1  
F2  
3. Select Edit.  
4. From the Edit screen, press the  
key until the  
The Read selection allows read-only access  
(SNMP “Get”) to the accessible objects in the  
MIB when community name 1 is used. The R/W  
selection allows Read/Write access (SNMP “Get”  
and “Set”) to the objects in the MIB. Write access  
is allowed for all objects specified as read/write in  
the MIB. Read access is allowed for all objects  
specified as read-only or read/write.  
Alarm selection appears on the screen.  
5. Select Alarm.  
Edit:  
User Alarm SNMP  
F3  
F1  
F2  
Configuring SNMP Traps  
A trap is an unsolicited message that is sent from the  
E1 NTU to an SNMP manager when the device detects  
certain, pre-specified conditions. These traps enable the  
SNMP manager to monitor the state of the network.  
6. Press F1 (Next) until the SNMP Trap  
configuration option appears.  
7. Press F2 (Enab) to enable trap messages over the  
SNMP management link.  
The SNMP Trap configuration option must be enabled  
for trap messages to be sent over the communications  
link. You must specify the number of SNMP managers  
that are to receive traps from this device, an IP address for  
each SNMP manager specified, and the type of traps to be  
sent from this device. For more information, refer to  
section in Chapter 4, Maintenance.  
SNMP Trap:  
Next Enab  
Disab  
F3  
F1  
F2  
3-18  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Operation  
Selecting the Number of Trap Managers  
Configuring a Destination for SNMP Traps  
If you intend to issue traps to an SNMP manager(s)  
from this device, you must specify the number of SNMP  
managers that are to receive the traps.  
A destination must be configured for each SNMP trap  
manager specified. This configuration option is displayed  
for the number of trap managers specified by the Number  
of Trap Managers configuration option.  
To specify the number of SNMP managers to receive  
traps from this device,  
To configure an IP address for the SNMP trap  
manager,  
1. From the top-level menu screen, select Cnfig.  
1. From the top-level menu screen, select Cnfig.  
2. Select the configuration option set to be copied  
into the Edit area by using the appropriate  
2. Select the configuration option set to be copied  
into the Edit area by using the appropriate  
Function key. Use the scroll keys, if necessary.  
Function key. Use the scroll keys, if necessary.  
3. Select Edit.  
3. Select Edit.  
4. From the Edit screen, press the  
key until the  
SNMP selection appears on the screen.  
4. From the Edit screen, press the  
key until the  
SNMP selection appears on the screen.  
5. Select SNMP.  
5. Select SNMP.  
Edit:  
User Alarm SNMP  
Edit:  
User Alarm SNMP  
F3  
F1  
F2  
F3  
F1  
F2  
6. From the SNMP Config screen, select Trap.  
6. From the SNMP Config screen, select Trap.  
SNMP Config:  
Gen  
Trap  
SNMP Config:  
Gen  
Trap  
F3  
F1  
F2  
F3  
F1  
F2  
7. Select the number of SNMP managers to receive  
traps (from 1 through 6) by using the appropriate  
Function key. Use the scroll keys, if necessary.  
7. Press F1 (Next) until the Trapn IP Address  
configuration option appears.  
8. Press F2 (Edit) to edit the IP address. You have the  
option of using F3 (Clear) to reset the IP address  
to the factory default 000.000.000.000. Refer to  
more information on setting an IP address.  
Num Trap Mgrs:1  
Next  
1
2
F3  
F1  
F2  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-19  
 
ACCULINK 336x E1 NTU  
9. Press F1 (Next) until the Trapn Destination  
configuration appears, and select the destination  
for the SNMP trap by using the appropriate  
Function key. Use the scroll keys, if necessary.  
NOTE  
If TS16 is reserved for CCS, D16  
will automatically be assigned to  
N16, and the G.703 DTE DS0  
channels allocated to the network  
must be directly connected to the  
corresponding channel (e.g., D1  
to N1, D2 to N2, etc.).  
Trapn Dst:  
Next None Com  
F3  
F1  
F2  
To allocate DS0 channels, begin by defining the logical  
channel configuration for the network interface, and then  
the G.703 DTE interface, and then any ports, if desired.  
diagrams of channel configurations.  
Configuring DS0 Channels  
The E1 NTU provides channel configuration options  
that allow you to do the following:  
NOTE  
Display the DS0 assignments for the network,  
G.703 DTE, and data port interfaces.  
With the exception of time-slot 16,  
a CAS allocation example is the  
same as the example in Figures  
3-8 and 3-9. TS16, however, is  
directly connected when using  
CAS (D16 to N16).  
Allocate DS0 channels on the G.703 DTE interface  
to the network interface.  
Allocate DS0 channels on the network or G.703  
DTE interface to particular data ports.  
Specify whether time-slot 16 (TS16) is available for  
data or reserved for signaling information using  
Common-Channel Signaling (CSS) or  
Blank configuration worksheets are provided at the  
the configuration worksheets for DS0 channel allocation:  
Channel-Associated Signaling (CAS).  
1. Complete the Network Interface and the G.703  
DTE Interface tables (unless the G.703 DTE  
interface is disabled) as shown in the examples in  
NOTE  
CCS is typically used in a 2-frame  
multiframe system, whereas CAS  
is used in a 16-frame system.  
2. Using the worksheets shown in Figures 3-10  
and 3-11, circle the configuration options needed  
to implement the logical channel configuration.  
Clear (deallocate) all DS0 channels from the  
network, G.703 DTE, or data port interface.  
Once you have completed the worksheets, enter this  
Map data from one port to another.  
3-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
   
Operation  
G.703 DTE INTERFACE  
D1  
D2  
NETWORK INTERFACE  
D3  
(N1-D1, N2-D2, ETC.)  
N1  
D4  
N2  
D5  
N3  
D6  
N4  
D7  
N5  
D8  
N6  
D9  
N7  
D10  
D11  
D12  
D13  
D14  
D15  
D16  
D17  
D18  
D19  
D20  
D21  
D22  
D23  
D24  
D25  
D26  
D27  
D28  
D29  
D30  
D31  
N8  
N9  
N10  
N11  
N12  
N13  
N14  
N15  
N16  
N17  
N18  
N19  
N20  
N21  
N22  
N23  
N24  
N25  
N26  
N27  
N28  
N29  
N30  
N31  
AUTOMATIC ALLOCATION  
PORTS  
PRT 1  
PRT 2  
PRT 3  
PRT 4  
496-14880  
Figure 3-6. Example of Channel Allocation with TS16 Reserved for Common-Channel Signaling  
3360-A2-GB20-20  
December 1996  
3-21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
ACCULINK 336x E1 NTU  
Network Interface  
Network Channel Allocation  
G.703 DTE Interface  
G.703 Channel Allocation  
N1  
N2  
N3  
N4  
N5  
N6  
N7  
N8  
N9  
D1  
D2  
D3  
D4  
D5  
D1  
N1  
N2  
N3  
N4  
N5  
D2  
D3  
D4  
D5  
D6  
D7  
D8  
D9  
N10  
N11  
D10  
D11  
D12  
D13  
D10  
D11  
D12  
D13  
D14  
D15  
D16  
D17  
D18  
D19  
D20  
D21  
D22  
D23  
D24  
D25  
D26  
D27  
D28  
D29  
D30  
D31  
Allocations  
N10  
N11  
N12  
N13  
N12  
N13  
N14  
N15  
N16  
N17  
N18  
N19  
N20  
N21  
N22  
N23  
N24  
N25  
N26  
N27  
N28  
N29  
N30  
N31  
Allocations  
D16  
N16  
Prt1  
Prt1  
Prt3  
Prt2  
Prt2  
Prt2  
Prt2  
Prt2  
Prt2  
Prt3  
D1 – D31 indicates allocation to DTE  
(G.703) channels.  
N1 – N31 indicates allocation to network  
channels.  
Prt1 – Prt4 indicates allocation to  
synchronous data ports.  
Figure 3-7. Example of Interface Worksheet with TS16 Reserved for Common Channel Signaling  
3-22  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Operation  
G.703 DTE INTERFACE  
D1  
D2  
NETWORK INTERFACE  
D3  
N1  
D4  
N2  
D5  
N3  
D6  
N4  
D7  
N5  
D8  
N6  
D9  
N7  
D10  
D11  
D12  
D13  
D14  
D15  
D16  
D17  
D18  
D19  
D20  
D21  
D22  
D23  
D24  
D25  
D26  
D27  
D28  
D29  
D30  
D31  
N8  
N9  
N10  
N11  
N12  
N13  
N14  
N15  
N16  
N17  
N18  
N19  
N20  
N21  
N22  
N23  
N24  
N25  
N26  
N27  
N28  
N29  
N30  
N31  
PORTS  
PRT 1  
PRT 2  
PRT 3  
PRT 4  
496-14879  
Figure 3-8. Example of Channel Allocation with TS16 Available for Data  
3360-A2-GB20-20  
December 1996  
3-23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ACCULINK 336x E1 NTU  
Network Interface  
Network Channel Allocation  
G.703 DTE Interface  
G.703 Channel Allocation  
N1  
N2  
N3  
N4  
N5  
N6  
N7  
N8  
N9  
D1  
D2  
D3  
D4  
D1  
N1  
N2  
N3  
N4  
N6  
D2  
D3  
D4  
D5  
D5  
D6  
D7  
D8  
D9  
N10  
N11  
D10  
D11  
D12  
D13  
D16  
D10  
D11  
D12  
D13  
D14  
D15  
D16  
D17  
D18  
D19  
D20  
D21  
D22  
D23  
D24  
D25  
D26  
D27  
D28  
D29  
D30  
D31  
Allocations  
N10  
N11  
N12  
N13  
N12  
N13  
N14  
N15  
N16  
N17  
N18  
N19  
N20  
N21  
N22  
N23  
N24  
N25  
N26  
N27  
N28  
N29  
N30  
N31  
Allocations  
Prt1  
N14  
Prt1  
Prt1  
Prt3  
Prt2  
Prt2  
Prt2  
Prt2  
Prt2  
Prt2  
Prt3  
D1 – D31 indicates allocation to DTE  
(G.703) channels.  
N1 – N31 indicates allocation to network  
channels.  
Prt1 – Prt4 indicates allocation to  
synchronous data ports.  
Figure 3-9. Example of Interface Worksheet with TS16 Available for Data  
3-24  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Operation  
Port Chan  
Conf  
Options  
Value  
Assign To  
Assign By  
NET, DTE, Prt2, Prt3, Prt4  
Block, Chan  
Port Rate  
Nx64: 64, 128, 192, 256, 320, 384, 448, 512, 576,  
640, 704, 768, 832, 896, 960, 1024, 1088, 1152,  
1216, 1280, 1344, 1408, 1472, 1536, 1600, 1664,  
1728, 1792, 1856, 1920, 1984  
NOTE: If time-slot 16 is reserved for signaling, the  
If Assign By Block  
If Assign By Chan  
Port 1  
highest port rate (1984) does not appear.  
Start At  
Time Slot (Nn or Dn): 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,  
12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25,  
26, 27, 28, 29, 30, 31 (Select One)  
Time Slot (Nn or Dn): 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,  
12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25,  
26, 27, 28, 29, 30, 31 (Select Multiple)  
Assign To  
Assign By  
NET, DTE, Prt1, Prt3, Prt4  
Block, Chan  
Port Rate  
Nx64: 64, 128, 192, 256, 320, 384, 448, 512, 576,  
640, 704, 768, 832, 896, 960, 1024, 1088, 1152,  
1216, 1280, 1344, 1408, 1472, 1536, 1600, 1664,  
1728, 1792, 1856, 1920, 1984  
NOTE: If time-slot 16 is reserved for signaling, the  
If Assign By Block  
If Assign By Chan  
Port 2  
highest port rate (1984) does not appear.  
Start At  
Time Slot (Nn or Dn): 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,  
12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25,  
26, 27, 28, 29, 30, 31 (Select One)  
Time Slot (Nn or Dn): 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,  
12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25,  
26, 27, 28, 29, 30, 31 (Select Multiple)  
Figure 3-10. Port Channel Configuration Worksheet (Ports 1 and 2)  
3360-A2-GB20-20  
December 1996  
3-25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCULINK 336x E1 NTU  
Port Chan  
Conf  
Options  
Value  
Assign To  
Assign By  
NET, DTE, Prt1, Prt2, Prt4  
Block, Chan  
Port Rate  
Nx64: 64, 128, 192, 256, 320, 384, 448, 512, 576,  
640, 704, 768, 832, 896, 960, 1024, 1088, 1152,  
1216, 1280, 1344, 1408, 1472, 1536, 1600, 1664,  
1728, 1792, 1856, 1920, 1984  
NOTE: If time-slot 16 is reserved for signaling, the  
If Assign By Block  
If Assign By Chan  
Port 3  
highest port rate (1984) does not appear.  
Start At  
Time Slot (Nn or Dn): 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,  
12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25,  
26, 27, 28, 29, 30, 31 (Select One)  
Time Slot (Nn or Dn): 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,  
12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25,  
26, 27, 28, 29, 30, 31 (Select Multiple)  
Assign To  
Assign By  
NET, DTE, Prt1, Prt2, Prt3  
Block, Chan  
Port Rate  
Nx64: 64, 128, 192, 256, 320, 384, 448, 512, 576,  
640, 704, 768, 832, 896, 960, 1024, 1088, 1152,  
1216, 1280, 1344, 1408, 1472, 1536, 1600, 1664,  
1728, 1792, 1856, 1920, 1984  
NOTE: If time-slot 16 is reserved for signaling, the  
If Assign By Block  
If Assign By Chan  
Port 4  
highest port rate (1984) does not appear.  
Start At  
Time Slot (Nn or Dn): 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,  
12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25,  
26, 27, 28, 29, 30, 31 (Select One)  
Time Slot (Nn or Dn): 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,  
12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25,  
26, 27, 28, 29, 30, 31 (Select Multiple)  
Figure 3-11. Port Channel Configuration Worksheet (Ports 3 and 4)  
3-26  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
3. Select Edit.  
NOTE  
4. From the Edit screen, press the  
key until the  
The following procedures are  
examples only. Screen displays  
may vary depending on the  
model and configuration of the  
E1 NTU.  
Chan selection appears on the screen.  
5. Select Chan.  
Edit:  
Port  
NET  
Chan  
Displaying DS0 Channel Assignments  
F3  
F1  
F2  
Use the Display command (in the Channel  
Configuration branch) to view how the DS0 channels are  
currently allocated.  
6. From the Channel Config screen, select Dsply  
(display).  
Line 1 of the display shows the 31 channels of the  
selected interface. Pressing the  
or  
key scrolls the  
channels onto the screen in groups of three. Line 2  
displays what is allocated to the DS0 channel listed in  
Line 1. Symbols used in the display are shown in  
Channel Config:  
Dsply Clear DTE  
F3  
F1  
F2  
Table 3-5  
Display Channel Symbols  
7. From the Display Chan screen, select NET to  
display the channels allocated to the network  
interface.  
Symbol  
Meaning  
The DS0 channel is not allocated.  
Prtn  
The DS0 channel is allocated to Port n,  
where n is 1, 2, 3, or 4.  
Display Chan:  
NET  
DTE  
Ports  
Nn  
The DS0 channel is allocated to the  
network interface DS0 channel n, where  
n can be any number from 1 through 31.  
F3  
F1  
F2  
Dn  
The DS0 channel is allocated to the  
G.703 DTE interface DS0 channel n,  
where n can be any number from 1  
through 31.  
Or, select DTE to display the channels allocated to  
the G.703 DTE interface.  
Display Chan:  
NET  
DTE  
Ports  
To display the DS0 channel allocation,  
F3  
F1  
F2  
1. From the top-level menu screen, select Cnfig.  
2. Select the configuration option set to be copied  
into the Edit area by using the appropriate  
Function key. Use the scroll keys, if necessary.  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-27  
     
ACCULINK 336x E1 NTU  
8. If you selected NET the channels allocated to the  
network interface are displayed. Line 1 displays  
the 31 channels for the network interface, while  
Line 2 displays what is allocated to the DS0  
Once a port is selected, you have access to the  
configuration options to complete the port allocation  
procedure. These configuration options enable you to,  
Assign the selected port to the desired interface  
Select the desired method for channel allocation  
channel shown in Line 1. Pressing the  
or  
key scrolls the channels onto the screen in groups  
of three.  
Select the port rate and starting channel (if the  
allocation method is block)  
N1  
D2  
N2  
D3  
N3  
Prt1  
Select the specific channels (if the allocation  
method is by individual channel)  
F3  
F1  
F2  
These configuration options are explained in detail in  
To select the data port,  
If you selected DTE, the channels allocated to the  
G.703 DTE interface are displayed. Line 1  
displays the 31 channels for the G.703 DTE  
interface, while Line 2 displays what is allocated  
to the DS0 channel shown in Line 1.  
1. From the top-level menu screen, select Cnfig.  
2. Select the configuration option set to be copied  
into the Edit area by using the appropriate  
Function key. Use the scroll keys, if necessary.  
D1  
D2  
N1  
D3  
N2  
3. Select Edit.  
4. From the Edit screen, press the  
key until the  
Chan selection appears on the screen.  
F3  
F1  
F2  
5. Select Chan.  
Allocating Data Ports  
Edit:DTE  
By using the configuration options, assign a specific  
port to DS0 channels on either the network interface or  
the G.703 DTE interface. The following methods are  
available to assign DS0 channels to the port:  
Port  
NET  
Chan  
F3  
F1  
F2  
Block – Allows a block of contiguous channels to be  
assigned by specifying a data port rate and an initial DS0  
channel (the first DS0 channel in a block of DS0  
channels). The number of channels assigned is determined  
by the port rate. Only those initial DS0 channel numbers  
that provide enough bandwidth (based on the port’s data  
rate) are displayed on the screen. These channels are  
automatically assigned to the destination E1 interface  
(HDSL or G.703 DTE) when the initial DS0 channel is  
selected.  
6. From the Channel Config screen, press the  
key to scroll the ports onto the screen.  
Channel Config:  
Dsply Clear DTE  
F3  
F1  
F2  
Chan – Individually selects the DS0 channels to  
allocate to the data port. The data port rate is  
automatically determined based on the number of  
channels selected.  
3-28  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Operation  
7. Select the desired port by pressing its  
corresponding Function key.  
2. Press F1 (Next) to display the next configuration  
option (Port Rate).  
3. Use the  
or  
key to scroll the desired port  
Channel Config:  
rate onto the screen. Rates scroll in groups of  
three. Available selections depend on the current  
base rate selected for the port. Press the  
corresponding Function key to select the port rate.  
Then, select Next to display the Start At  
configuration option on the screen.  
Prt1  
Prt2  
Prt3  
F3  
F1  
F2  
8. The configuration option for the data port channel  
allocation destination appears on the screen. Select  
NET to assign this port to the network interface,  
select DTE to assign this port to the G.703 DTE  
Port Rate:384  
Next  
64  
128  
interface, or press the  
key and the appropriate  
F3  
F1  
F2  
Function key to assign this port to another port.  
Assign To:NET  
4. The Start At screen displays the configuration  
option used to select the starting DS0 channel. If  
the destination selected is the network interface,  
then the network channels appear on the screen. If  
the destination selected is the G.703 DTE  
interface, then these channels appear on the  
screen.  
Next  
NET  
DTE  
F3  
F1  
F2  
9. Press F1 (Next) to display the appropriate  
configuration options on the screen. Use one of  
the following examples, depending on whether  
you are assigning by block or individual channel.  
The following screen shows an example for the  
network interface. Use the  
or  
key to  
scroll the desired channel onto the screen. Use the  
Function keys to select the starting channel. Only  
those DS0 channel numbers that provide enough  
bandwidth (based on the configured data rate) to  
be used as a starting channel number are  
Block Channel Assignment Method  
The Assign By configuration option screen appears  
after you select a port.  
displayed. Channel allocation for this port can  
only be cleared by selecting Clear.  
To assign by the block method,  
1. Press F2 (Block).  
Start At:Clear  
Next  
Clear N1  
F3  
F1  
F2  
Assign By:  
Next  
Block Chan  
F3  
F1  
F2  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-29  
   
ACCULINK 336x E1 NTU  
Individual Channel Assignment Method  
Allocating DS0 Channels from the G.703  
DTE Interface to the Network Interface  
The Assign By configuration option screen appears  
after you select a port.  
By using the configuration options, you can allocate  
DS0 channels from the G.703 DTE interface to the  
network interface and specify whether time-slot 16 (TS16)  
is reserved for signaling information.  
To assign by the individual channel method,  
1. Press F3 (Chan).  
To allocate DS0 channels from the G.703 DTE  
interface to the network interface,  
Assign By:  
Next  
Block Chan  
1. From the top-level menu screen, select Cnfig.  
F3  
F2  
F1  
2. Select the configuration option set to be copied  
into the Edit area by using the appropriate  
Function key. Use the scroll keys, if necessary.  
2. Press F1 (Next) to display the next configuration  
option (channel allocation).  
3. Select Edit.  
4. From the Edit screen, press the  
key until the  
3. Line 1 displays the 31 channels for the network  
interface or the G.703 DTE interface, depending  
on which destination was chosen. This example  
assumes that the network is the destination. Line 2  
displays what is allocated to the DS0 channel  
Chan selection appears on the screen.  
5. Select Chan.  
shown in Line 1. Pressing the  
or  
key  
Edit:  
Port  
scrolls the channels onto the screen in groups of  
three. Select the channel by pressing the Function  
key under the desired number. Portn appears. The  
port is assigned to that channel. To deallocate a  
port, press the Function key under that port  
number. Pressing the Function key under channels  
assigned to other ports has no effect.  
NET  
Chan  
F3  
F1  
F2  
6. From the Channel Config screen, select DTE.  
N1  
Prt1  
N2  
Prt2  
Channel Config:  
Dsply Clear DTE  
Next  
F3  
F1  
F2  
F3  
F1  
F2  
NOTE  
N16 will not appear if time-slot 16  
(TS16) is reserved for signaling.  
(The default is TS16 available for  
data.)  
3-30  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
 
Operation  
7. From the DTE Channels screen, select TS16.  
10. From the DTE Channels screen, select Assign.  
DTE Channels:  
TS16 Assign  
DTE Channels:  
TS16 Assign  
F3  
F3  
F1  
F2  
F1  
F2  
8. Pressing F2 (Rsvd) reserves time-slot 16 for  
Common-Channel Signaling (CSS). Pressing F3  
(CAS) selects Channel-Associated Signaling. Data  
is the default for TS16.  
11. Press the Function key below the network channel  
desired. Each time that you press the Function key,  
the DTE channel number will scroll up one  
number. If the network channel is currently  
unassigned (‘‘–” is displayed on Line 2), the DTE  
channel number initially displays the same number  
as the corresponding network channel number.  
However, if the network channel is currently  
assigned, the DTE channel number is shown as  
Dn. Pressing the Function key for D31 wraps the  
display back to D1. Only those channels that are  
not already assigned will appear on the LCD when  
scrolling. The network channels assigned to ports  
(Prt1...Prt4) are unavailable for assignment.  
TS16:Data  
Data  
Rsvd CAS  
F3  
F1  
F2  
NOTE  
If TS16 is reserved for CSS by  
selecting Rsvd, D16 will be  
assigned to N16, and the G.703  
DTE DS0 channels allocated to  
the network must be directly  
connected to the corresponding  
channel (e.g., D1 to N1, D2 to N2,  
etc.).  
N1  
D1  
N2  
D2  
N3  
F3  
F1  
F2  
9. From the TS16 screen, press the  
to the DTE Channels screen.  
key to return  
TS16:Data  
Data  
Rsvd CAS  
F3  
F1  
F2  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-31  
ACCULINK 336x E1 NTU  
6. From the Channel Config screen, select Clear.  
Clearing DS0 Channel Allocation  
You can clear (deallocate) all the DS0 channels  
currently allocated to either the network interface, the  
G.703 DTE interface, or the synchronous data ports.  
Channel Config:  
Dsply Clear DTE  
To clear DS0 channel allocation,  
F3  
F1  
F2  
1. From the top-level menu screen, select Cnfig.  
2. Select the configuration option set to be copied  
into the Edit area by using the appropriate  
7. From the Clear Channel screen, select NET to  
clear all DS0 channels assigned to the network  
interface. Or, select DTE to clear all DS0 channels  
assigned to the G.703 DTE interface. Or, select a  
port to clear all assignments for that data port.  
Function key. Use the scroll keys, if necessary.  
3. Select Edit.  
4. From the Edit screen, press the  
key until the  
Chan selection appears on the screen.  
Clear Channel:  
NET  
DTE  
Port1  
5. Select Chan.  
F3  
F1  
F2  
Edit:  
Port  
NET  
Chan  
F3  
F1  
F2  
3-32  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
   
Operation  
The clock source configuration options enable you to  
select either the network interface, a synchronous data  
port, the internal clock, the G.703 DTE interface, or an  
external clock. If external clocking is selected, you must  
use the clock rate configuration option to specify the clock  
configurations. Two sample procedures for configuring  
more information on configuration options, refer to  
Selecting the Timing Source  
The E1 NTU provides the ability to select a primary  
clock (timing) source that is used to synchronize all of the  
E1 and data port interfaces on the E1 NTU. The clock for  
each interface is at the appropriate rate for that interface  
(e.g., 2.048 Mbps for the E1 interfaces, the configured  
port rate for the data ports), and it is independent of the  
primary clock rate. This means that the primary clock rate  
and the E1 NTU interface rates may be different.  
The E1 NTU automatically falls back to the secondary  
clock when a failure of the selected primary clock is  
detected. If a secondary clock failure is detected, the E1  
NTU falls back to its internal clock.  
NOTE  
External clock and secondary  
clock sources are only available  
for 2-port and 4-port E1 NTUs.  
NETWORK  
CLOCK: NETWORK  
CLOCK: NETWORK  
CLOCK: INTERNAL  
CLOCK: NETWORK  
CLOCK: EXTERNAL  
CLOCK: NETWORK  
CLOCK: NETWORK  
PBX  
CLOCK: DTE (G.703) CONNECTOR  
TERMINAL  
EQUIPMENT  
CLOCK: PORT 1, 2, 3, OR 4  
CLOCK: NETWORK  
496-14341-03  
Figure 3-12. Common Clocking Configurations  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-33  
     
ACCULINK 336x E1 NTU  
Configuring for Network Timing  
Configuring for External Timing  
To configure for network timing,  
To configure 2-port and 4-port E1 NTUs for external  
timing,  
1. From the top-level menu screen, select Cnfig.  
1. From the top-level menu screen, select Cnfig.  
2. Select the configuration option set to be copied  
into the Edit area by using the appropriate  
2. Select the configuration option set to be copied  
into the Edit area by using the appropriate  
Function key. Use the scroll keys, if necessary.  
Function key. Use the scroll keys, if necessary.  
3. Select Edit.  
3. Select Edit.  
4. From the Edit screen, press the  
key until the  
Gen selection appears on the screen.  
4. From the Edit screen, press the  
key until the  
Gen selection appears on the screen.  
5. Select Gen.  
5. Select Gen.  
Edit:  
NET  
Chan Gen  
Edit:  
NET  
Chan Gen  
F3  
F1  
F2  
F3  
F1  
F2  
6. Select the primary clock source. For network,  
press F2 (note that network is also the default).  
6. Select the primary clock source. For external,  
press the  
key until the Ext selection appears  
on the screen.  
Pri Clk Src:NET  
Next  
NET  
DTE  
Pri Clk Src:NET  
Next  
NET  
DTE  
F3  
F1  
F2  
F3  
F1  
F2  
NOTE  
7. Select Ext (external timing).  
The procedure for configuring the  
secondary clock source is similar  
to the example shown above. For  
more information on configuration  
Pri Clk Src:NET  
Prtn  
Int  
Ext  
F3  
F1  
F2  
3-34  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
   
Operation  
8. Select the appropriate external clock rate by  
pressing the corresponding Function key. This step  
is mandatory if you have chosen external clocking.  
The inactive interface displays the following message  
when a Function key is pressed or a connection is made  
on the inactive user interface and control cannot be  
switched because the currently active interface is in use.  
On the screen, either Ft. Panel (front panel) or COM Port  
is displayed in the user interface (User I/F) field.  
Clock Rate:2048  
Next  
2048  
8
E1 HDSL NTU  
User I/F active  
F3  
F1  
F2  
F3  
F1  
F2  
Acquiring/Releasing  
the User Interface  
You can access the user interface from either the front  
panel or the COM port. The E1 NTU allows only one user  
interface to be active at a time. The front panel is the  
default user interface at power-up or after a reset. It is also  
the default during a software download or when a failure  
occurs at either the local or remote PC interface.  
The inactive interface displays the following message  
after control has been released from the previously active  
interface and another interface has not become active.  
E1 HDSL NTU  
User I/F idle  
F3  
F1  
F2  
You can switch an inactive user interface to active if,  
The current active user interface has had no activity  
(no key was pressed) for at least five minutes,  
and/or  
Releasing the Active User Interface  
To release the current active user interface, either allow  
five minutes to elapse without pressing any key or use the  
Release command.  
The active user interface has been released with the  
Release command.  
To use the Release command,  
Acquiring the Active User Interface  
1. From the top-level menu screen, press the  
until the Ctrl selection appears on the screen.  
key  
To acquire the active user interface, press any key. If  
you are using the PC interface, use the mouse to click on  
the desired Function key.  
The top-level menu screen appears on the active user  
interface, regardless of what screen was displayed at the  
previous active user interface.  
E1 HDSL NTU  
Stat  
Test  
Cnfig  
F3  
F1  
F2  
E1 HDSL NTU  
Stat  
Test  
Cnfig  
2. Select Ctrl.  
F3  
F1  
F2  
E1 HDSL NTU  
Test Cnfig Ctrl  
F3  
F1  
F2  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-35  
     
ACCULINK 336x E1 NTU  
3. From the Control screen, select Rel (Release).  
3. From the Control screen, press the  
key until  
the Reset selection appears on the screen.  
Control:  
Rel  
LED ClrReg  
Control:  
Rel  
LED ClrReg  
F3  
F1  
F2  
F3  
F1  
F2  
The active user interface is released. A screen with  
this message appears. No user interface is active  
until input is received from a user interface.  
4. Select Reset.  
Control:  
ClrReg Reset  
Ft. Panel:  
Released  
F3  
F1  
F2  
F3  
F1  
F2  
5. From the Device Reset screen, press F1 to initiate  
a reset of the E1 NTU (the power-up sequence  
screen appears). Press F2 instead to return to the  
Control screen without initiating a reset.  
Resetting the E1 NTU  
Use the Reset command to perform a power-on reset of  
the E1 NTU.  
Device Reset:  
To reset the E1 NTU,  
Yes  
No  
1. From the top-level menu screen, press the  
until the Ctrl selection appears on the screen.  
key  
F3  
F1  
F2  
E1 HDSL NTU  
Stat  
Test  
Cnfig  
Download Operations  
F3  
F1  
F2  
NOTE  
The Download command is for  
use by service personnel only.  
Loss of primary data could result  
from improper use.  
2. Select Ctrl.  
E1 HDSL NTU  
Test Cnfig Ctrl  
F3  
F1  
F2  
3-36  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
     
Operation  
E1 NTU User Interface  
Access Security  
The E1 NTU User Interface Access Security section of  
this document is not available for viewing online due to  
its security-sensitive contents.  
To order this manual, please contact your sales or  
service representative.  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-37  
Maintenance  
4
Self-Test Health . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2  
HDSL Loop Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5  
Monitoring Test Patterns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-23  
Overview  
NOTE  
The E1 NTU can detect and report faults, and perform  
diagnostic tests. These features ensure that your E1 NTU  
is giving you optimum performance in your network.  
The following procedures are  
examples only. Screen displays  
may vary depending on the  
configuration of the E1 NTU.  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-1  
   
ACCULINK 336x E1 NTU  
2. From the Status screen, select STest.  
Self-Test Health  
Use the Self-Test Health command to display the  
results of the power-up self-test. Possible messages are  
information about power-up self-test.  
Status:  
HDSL DevHS STest  
F3  
F1  
F2  
To display power-up self-test results,  
1. From the top-level menu screen, select Stat.  
3. View the results of the last power-up self-test. If  
no problems were found during power-up, the  
following message appears.  
E1 HDSL NTU  
Stat  
Test  
Cnfig  
SelfTst Health:  
Passed  
F3  
F1  
F2  
F3  
F1  
F2  
Table 4-1  
Self-Test Health Messages  
Message  
Description  
Passed  
No problems were found during power-up.  
CPU fail  
The central processing unit failed internal testing.  
Device fail  
HDSL fail  
One or more of the unit’s integrated circuit chips failed to pass internal device level testing.  
The unit failed to successfully test an internal HDSL subassembly.  
The unit failed to encode data properly or to detect Loss Of Signal.  
The unit failed to transmit AIS or to detect an RAI alarm.  
The unit failed program checksum verification.  
HDB3/LOS fail  
Alarm fail  
Memory fail  
LCD fail  
The front panel liquid crystal display (LCD) failed.  
NET Lp1 fail*  
NET Lp2 fail*  
NET E1 fail  
DTE E1 fail  
DSU fail  
The unit failed to internally loop data on the network loop 1 circuit.  
The unit failed to internally loop data on the network loop 2 circuit.  
The unit failed to internally loop data on the network E1 circuit.  
The unit failed to internally loop data on the DTE E1 circuit.  
The unit failed to internally loop data on the DSU.  
DSU Portn fail  
Port’s integrated circuitry failed to pass device internal testing.  
Unknown Exp Dev The unit is not able to recognize the expansion device connected to the main circuit card.  
Failure xxxxxxxx An 8-digit hexadecimal failure code is provided for service personnel.  
* Not available on all units.  
4-2  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Maintenance  
Alarm/status messages appear on Line 2 of the  
Device Health and Status  
Use the Device Health and Status branch to view the  
current health and status messages for the E1 NTU.  
LCD in priority order (highest to lowest). The E1  
NTU is polled for current status every ten seconds.  
If the status has changed from the last poll, the  
Health and Status screen is updated and the  
highest priority message is displayed.  
To display device health and status,  
3. Use the scroll keys, if necessary, to scroll  
additional device health and status messages onto  
the LCD.  
1. From the top-level menu screen, select Stat.  
E1 HDSL NTU  
Stat  
Test  
Cnfig  
Device H/S:  
LOS on Loop1  
F3  
F1  
F2  
F3  
F1  
F2  
2. From the Status screen, select DevHS.  
The Auto Device Health and Status screen appears  
when there is no activity (no keys pressed) on the  
active physical interface for five minutes. Only the  
highest priority message appears on Line 2 of the  
LCD.  
Status:  
HDSL DevHS STest  
F3  
F1  
F2  
Table 4-2  
(1 of 2)  
Health and Status Messages  
Message  
Description  
LOS on Loop1  
A Loss Of Signal condition (6 consecutive synchronization word mismatches) has been detected  
on loop 1 of the network interface. The condition is cleared when a signal match occurs.  
LOS on Loop2  
LOS at DTE  
OOF at Net  
A Loss Of Signal condition has been detected on loop 2 of the network interface. The condition is  
cleared when a signal match occurs.  
A Loss Of Signal condition (175 consecutive zeros) has been detected on the G.703 DTE interface.  
The condition is cleared when the density of ones to zeros received is 12.5%.  
An Out Of Frame condition (3 consecutive errored frame alignment events or, in CRC4 mode, a  
lack of multiframe alignment) has been detected on the network interface. The condition is cleared  
when a reframe occurs.  
OOF at DTE  
An Out Of Frame condition has been detected on the G.703 DTE interface. The condition is  
cleared when a reframe occurs.  
AIS at Net  
AIS at DTE  
EER at Net  
An Alarm Indication Signal (unframed all ones signal) is being received by the network interface.  
An Alarm Indication Signal is being received by the G.703 DTE interface.  
An Excessive Error Rate condition has been detected on the network interface (the bit error rate  
-3  
is 10 or greater for 4 to 5 seconds). The condition is cleared when the error rate falls below the  
-4  
threshold value (10 ) for 5 seconds.  
3360-A2-GB20-20  
December 1996  
4-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
ACCULINK 336x E1 NTU  
Table 4-2  
(2 of 2)  
Health and Status Messages  
Message  
Description  
EER at DTE  
An Excessive Error Rate condition has been detected on the G.703 DTE interface. The condition is  
cleared when the error rate falls below the threshold value (10 ) for 5 seconds.  
-4  
RAI at Net  
RAI at DTE  
MFA at Net  
A Remote Alarm Indication is being received by the network interface.  
A Remote Alarm Indication is being received by the G.703 DTE interface.  
A Multiframe Alarm condition (2 consecutive errored multiframe alignment signals, or two  
consecutive multiframes with all zeros in time-slot 16) has been detected on the network interface.  
The condition is cleared when realignment (or time-slot 16 correction) occurs.  
MFA at DTE  
A Multiframe Alarm condition has been detected on the G.703 DTE interface. The condition is  
cleared when realignment (or time-slot 16 correction) occurs.  
RMA at Net  
A Remote Multiframe Alarm signal is being received by the network interface.  
RMA at DTE  
Primary Clk fail  
Second Clk fail  
OOF at Prtn  
A Remote Multiframe Alarm signal is being received by the G.703 DTE interface.  
The primary clock has failed. Timing for the E1 NTU is provided by the secondary clock.  
The primary clock and the secondary clock have failed. Timing is provided by the internal clock.  
An Out Of Frame has been detected on data port Prtn (where n is the port number). This condition  
only occurs if the synchronous data port’s Embedded Data Link (EDL) is enabled (only available for  
2-port and 4-port E1 NTUs).  
EER at Prtn  
The error rate of the received signal has exceeded the configured threshold for data port Prtn  
(where n is the port number). This condition only occurs if the synchronous data port’s Embedded  
Data Link (EDL) is enabled (only available for 2-port and 4-port E1 NTUs). The condition is cleared  
when the error rate falls below the synchronous data port’s configured threshold value.  
PORT SNMP Down The SNMP management link is in a down state for PORT (where PORT is COM or AUX). This  
condition occurs if the PORT is configured for SNMP, and communication between the  
management system and the E1 NTU is not currently possible for this port. For the AUX port, this  
condition is detected only when a device reset or power-up occurs.  
Selftest failed  
A failure was detected during the power-on self-test. Select STest (in the Stat branch) to display  
more information about the failure.  
DevFail xxxxxxxx  
Download failed  
An internal error has been detected by the operating software. An 8-digit code appears for use by  
service personnel. The condition is cleared by resetting the device.  
A download attempt was interrupted and failed to complete. The condition is cleared by resetting  
the device.  
Test in progress  
Lp1/Lp2 Reversed  
NTU Operational  
A test is currently active. Select Tstat (in the Stat branch) to display more test information.  
The loop 1 and loop 2 connections on the HDSL network are reversed.  
This message only appears if the unit is configured as an NTU and there are no valid alarm or  
status messages.  
LTU Operational  
This message only appears if the unit is configured as an LTU and there are no valid alarm or  
status messages.  
4-4  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Maintenance  
HDSL messages appear on Line 2 of the LCD.  
HDSL Loop Performance  
Use the HDSL Loop Performance branch to view the  
signal quality and loop loss messages for each loop on the  
The E1 NTU is polled for current status every ten  
seconds. If the status has changed from the last  
poll, the HDSL screen is updated.  
3. Use the scroll keys, to scroll additional HDSL  
messages onto the LCD.  
To display HDSL loop performance,  
1. From the top-level menu screen, select Stat.  
HDSL:  
Lp1 SigQ=xx  
E1 HDSL NTU  
Stat  
Test  
Cnfig  
F3  
F1  
F2  
F3  
F1  
F2  
2. From the Status screen, select HDSL.  
Status:  
HDSL DevHS STest  
F3  
F1  
F2  
Table 4-3  
HDSL Loop Performance Messages  
Message  
Description  
Lp1 SigQ=xx  
The loop 1 signal quality value (xx) is 0 to 10. A value of 10 indicates the noise margin is 9 dB or  
more above the margin needed to produce a bit error rate of approximately 10 . The values of 2 to  
-7  
9 indicate noise margins of 1 to 8 dB above this margin. A value of 1 indicates the noise margin is  
-7  
less than or equal to the margin needed to produce a bit error rate of approximately 10 . A value of  
0 indicates the loop is out of synchronization or the noise margin is unavailable.  
Lp2 SigQ=xx  
Lp1 Loss=xx  
The loop 2 signal quality value (xx) is 0 to 10. (See the Lp1 SigQ description above.)  
The loop 1 loss value (xx) is 0 to 40. The value indicates an approximation (+/– 2 dB) of the loss  
that the E1 NTU detects at the interface to loop 1. Due to bridge taps on the loop, this value could  
be different at each end of the loop. (Values above 40 are invalid.)  
Lp2 Loss=xx  
The loop 2 loss value (xx) is 0 to 40. (See the Lp1 Loss description above.)  
3360-A2-GB20-20  
December 1996  
4-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
ACCULINK 336x E1 NTU  
2. From the Status screen, press the  
Perf selection appears on the screen.  
key until the  
Performance Reports  
Network performance is continuously monitored and  
maintained in network registers (NET), in G.703 DTE  
registers (DTE) and, if configured to do so, in far-end and  
near-end port registers (Prtn, where n is 1, 2, 3, or 4).  
Registers shown on the front panel LCD are listed in  
3. From the Status screen, select Perf.  
Status:  
DevHS STest Perf  
NET and DTE registers are status registers that collect  
performance data for the previous 24-hour period.  
Performance data is updated in 15-minute intervals. After  
15 minutes, the current interval is rolled over into a set of  
accumulator registers that represent the previous 96  
15-minute intervals for the register. An interval total of  
how many of the 96 registers contain valid data is also  
kept, as well as a 24-hour total for each accumulator  
register.  
F3  
F1  
F2  
4. Select NET registers.  
Performance:  
NET  
DTE  
Prt1  
For 2-port and 4-port E1 NTUs, port performance is  
continuously monitored and maintained in memory  
registers when the port is configured to use EDL. The  
E1 NTU maintains two sets of port registers for each  
synchronous data port: far-end port registers and near-end  
port registers. These registers are status registers that  
collect performance data for the previous 8-hour period.  
Port data is updated in 15-minute intervals. After  
15 minutes, the current interval is rolled over into a set of  
accumulator registers that represent the previous 32  
15-minute intervals for the register. An interval total of  
how many of the 32 registers contain valid data is also  
kept, as well as a 8-hour total for each accumulator  
register.  
F3  
F1  
F2  
5. From the NET Registers screen, select E1 to view  
the registers that apply to the E1 (G.704) network  
interface. Select Lp1 or Lp2 to view the HDSL  
loop 1 or loop 2 network interface registers. (In  
the following example, E1 is selected.)  
NET Registers:  
E1  
Lp1  
Lp2  
F3  
F1  
F2  
NOTE  
The following procedure is an  
example only. Screen displays  
may vary depending on the  
model and configuration of the  
E1 NTU. The procedure for  
displaying DTE and port registers  
is similar to this example.  
6. From the E1 Registers screen, press F1 to view  
E1 Registers:  
Cur  
24Tot Intvl  
To display network (NET) performance,  
F3  
F1  
F2  
1. From the top-level menu screen, select Stat.  
E1 HDSL NTU  
Stat  
Test  
Cnfig  
F3  
F1  
F2  
4-6  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
   
Maintenance  
7. When you press F1 from the E1 Registers screen,  
the E1 registers for the current 15-minute interval  
appear.  
You can reset the performance registers via the ClrReg  
command in the Control branch of the front panel menu.  
To clear the performance registers,  
1. From the top-level menu screen, press the  
until the Ctrl selection appears on the screen.  
key  
E1 Current:  
Event = xx,xxx  
2. Select Ctrl.  
F3  
F1  
F2  
E1 HDSL NTU  
Test  
Cnfig Ctrl  
8. When you press F2 from the E1 Registers screen,  
the E1 registers for the 24-hour total interval  
appear.  
F3  
F1  
F2  
E1 24 Hour:  
VldIntvl = xx  
3. From the Control screen, select ClrReg.  
F3  
F1  
F2  
Control:  
Rel  
LED ClrReg  
9. When you press F3 from the E1 Registers screen,  
the interval screen appears. Use this screen to  
choose the specific 15-minute interval.  
F3  
F1  
F2  
4. From the Clear Prf Regs screen, press F1 to clear  
the E1 registers.  
E1 Intvl: 01  
Up  
Down Dsply  
Clear Prf Regs:  
F3  
F1  
F2  
E1  
HDSL DTE  
F3  
F1  
F2  
10. Use the  
and  
keys to position the cursor  
under the first or second digit in the interval  
number displayed, then use the F1 (Up) and  
F2 (Down) keys to increment/decrement the  
number.  
If you selected E1, the E1 performance registers  
are cleared. All accumulators are reset to zero and  
all status registers are cleared, and the current  
interval timer, the number of valid intervals count  
and the total 24-hour counts are reset to zero. The  
Command Complete message then appears.  
11. When you have selected the number of the interval  
you want to display, press F3 (Dsply) to display  
the registers for the interval selected. Use the  
scroll keys to view additional register information.  
E1 Intvl: xx  
ES=xxx  
F3  
F1  
F2  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-7  
       
ACCULINK 336x E1 NTU  
Table 4-4  
(1 of 2)  
Performance Registers  
Register  
Interval Description  
Totals Description  
Event  
Error events counter. An error event is a frame  
N/A  
(Not valid for  
Lpn registers.)  
with either a Cyclic Redundancy Check (CRC)  
error or an Out Of Frame (OOF) event. The  
maximum count is 65,535. This register is only  
reset as a result of a Clear Performance  
Register command. This register is valid for the  
current interval only.  
CurTimer  
VldIntvl  
Current interval timer. This register records the  
number of seconds in the current 15-minute  
interval. The maximum is 900 seconds. This  
register is valid for the current interval only.  
N/A  
N/A  
Valid interval total. Records the number of valid  
15-minute intervals in the previous x hours, where x  
is 24 hours for aggregate performance and 8 hours  
for port performance. This register is not valid for the  
current interval.  
ES  
The number of errored seconds for the current  
interval. An errored second is any second with  
one or more of the following: errored frame  
alignment, CRC error, Loss of Signal (LOS),  
Alarm Indication Signal (AIS), or Loss of Frame  
(LOF). The maximum is 900 seconds.  
The total number of errored seconds for the previous  
x hours, where x is 24 hours for aggregate  
performance and 8 hours for port performance.  
UAS  
SES  
The number of unavailable seconds for the  
current interval. An unavailable second is any  
one second interval when service is  
unavailable. (Detection occurs with 10  
consecutive unavailable seconds.) The  
maximum is 900 seconds.  
The total number of unavailable seconds for the  
previous x hours, where x is 24 hours for aggregate  
performance and 8 hours for port performance.  
The number of severely errored seconds for the The total number of severely errored seconds for the  
current interval. For E1 or DTE registers, a previous x hours, where x is 24 hours for aggregate  
severely errored second is any second with 805 performance and 8 hours for port performance.  
or more CRC errors, 16 or more errored frame  
alignment signal events, or one or more LOS,  
AIS, or OOF event. For port registers, a  
severely errored second is any second with 320  
or more CRC errors, or one or more OOF  
event. For Lpn registers, a severely errored  
second is any second with 50 or more CRC6  
errors. The maximum is 900 seconds.  
BES  
(Not valid for  
The number of bursty errored seconds for the  
current interval. For E1 or DTE registers, a  
The total number of bursty errored seconds for the  
previous x hours, where x is 24 hours for aggregate  
Lpn registers.)  
bursty errored second is any second with more performance and 8 hours for port performance.  
than one, but less than 805, CRC errors when  
in CRC4 mode, or more than one, but less than  
16, errored frame alignment signals when in  
non-CRC4 mode. For port registers, a bursty  
errored second is any second with more than  
one, but less that 320, CRC errors. The  
maximum is 900 seconds.  
4-8  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Maintenance  
Table 4-4  
(2 of 2)  
Performance Registers  
Register  
Interval Description  
Totals Description  
LOFC  
The loss of frame count for the current interval. The total loss of frame count for the previous x  
(Not valid for  
Lpn registers.)  
This is a count of the number of times that an  
LOF is declared. The maximum count is 255.  
hours, where x is 24 hours for aggregate  
performance and 8 hours for port performance.  
StEvnt  
The status events register records whether one N/A  
or more of the following events have occurred  
at least once during the interval. The event is  
identified by a letter as follows:  
(Not valid for  
Lpn or port  
registers.)  
R – A Remote Alarm Indication has been  
received on the network interface or the  
G.703 DTE interface.  
L – Loss Of Signal has occurred on the  
network interface or the G.703 DTE  
interface.  
E – The Excessive Error Rate threshold has  
been exceeded.  
F – A Frame Synchronization Bit Error has  
been detected.  
V – A Bipolar Violation has been detected.  
If none of these events occurred during the  
interval, StEvnt=none will be displayed.  
FEBE  
The number of far-end block errors (reported by The total number of far-end block errors for the  
(Only valid for  
Lpn registers.)  
remote equipment) for the current interval. The  
maximum count is 900.  
previous x hours, where x is 24 hours for aggregate  
performance and 8 hours for port performance.  
Complete  
Bad line conditions or loopback tests may  
prevent far-end port statistics from reaching the  
E1 NTU. This field indicates whether the  
15-minute interval contains 900 seconds of  
statistics. If one or more seconds of far-end  
statistics are missing, this field will display  
Complete=No, otherwise it will display  
N/A  
(Only valid for  
far-end port  
registers.)  
Complete=Yes. This field is only displayed  
when Far is selected from the Prtn screen.  
3360-A2-GB20-20  
December 1996  
4-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ACCULINK 336x E1 NTU  
Loss of Multiframe alignment condition detected  
at the x Interface (where x is either Network or  
DTE).  
Alarms  
The E1 NTU can be attached, either locally or  
remotely, to an ASCII terminal or printer to display or  
print alarm messages. The Communications (COM) port  
can be used as the destination for Alarm Set and Alarm  
Clear messages. This enables an ASCII terminal or printer  
to monitor the E1 NTU for alarm conditions. Alarms can  
also be displayed on a PC that is using a terminal  
emulation package.  
Alarm Cleared. Loss of Multiframe alignment  
condition at the x Interface (where x is either  
Network or DTE).  
Remote Multiframe Alarm received at the x  
Interface (where x is either Network or DTE).  
Alarm Cleared. Remote Multiframe Alarm at  
the x Interface (where x is either Network or  
DTE).  
Each alarm message contains a customer identification  
to indicate which remote E1 NTU is reporting an alarm.  
For information about customer identification, refer to the  
For 2-port and 4-port E1 NTUs,  
Continuous Out Of Frame condition detected at  
synchronous data port n (where n is the port  
number).  
Possible alarm messages are as follows:  
Continuous Loss Of Signal detected at the x  
Interface (where x is either HDSL Network  
Loop 1, HDSL Network Loop 2, or DTE).  
Alarm Cleared. Out Of Frame condition at  
synchronous data port n (where n is the port  
number).  
Alarm Cleared. Loss of Signal condition at the x  
Interface (where x is either HDSL Network  
Loop 1, HDSL Network Loop 2, or DTE).  
An Excessive Error Rate has been detected at  
synchronous data port n (where n is the port  
number).  
Continuous Out Of Frame condition detected at  
the x Interface (where x is either Network or  
DTE).  
Alarm Cleared. An Excessive Error Rate at  
synchronous data port n (where n is the port  
number).  
Alarm Cleared. Out of Frame condition at the x  
Interface (where x is either Network or DTE).  
If two alarm conditions are detected at once, the higher  
priority alarm is reported. However, if an even higher  
priority alarm is detected before the first alarm is cleared,  
the later alarm is not reported. (The alarms listed above  
are in priority order with the highest priority listed first.)  
Alarm Indication Signal received at the x  
Interface (where x is either Network or DTE).  
Alarm Cleared. Alarm Indication Signal at the x  
Interface (where x is either Network or DTE).  
Alarms remain active until the alarm condition is  
cleared. Also, an alarm clear message is only sent when  
there are no other alarms active.  
An Excessive Error Rate has been detected at  
the x Interface (where x is either Network or  
DTE).  
For information about alarm configuration options,  
Appendix C, Configuration Options.  
Alarm Cleared. An Excessive Error Rate at the x  
Interface (where x is either Network or DTE).  
Remote Alarm Indication signal received at the  
x Interface (where x is either Network or DTE).  
For troubleshooting information, refer to the  
Alarm Cleared. Remote Alarm Indication signal  
at the x Interface (where x is either Network or  
DTE).  
4-10  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
   
Maintenance  
SNMP Traps  
Table 4-5  
Enterprise-Specific Trap Definitions  
A trap is an unsolicited message that is sent from the  
E1 NTU to an SNMP manager when the device detects  
certain, pre-specified conditions. These traps enable the  
SNMP manager to monitor the state of the network.  
Trap Value  
Event  
enterpriseClockFail(1)  
The currently configured  
primary clock source has  
failed.  
The SNMP Trap configuration option must be enabled  
for trap messages to be sent over the communications  
link. You must specify the number of SNMP managers  
that are to receive traps from this device, an IP address for  
each SNMP manager specified, and the type of traps to be  
sent from this device. For more information, refer to  
enterpriseSelfTestFail(2)  
A device hardware failure  
is detected at self-test.  
This trap is generated after  
device initialization.  
enterpriseDeviceFail(3)  
An internal device failure is  
detected by the operating  
software.  
Trap types consist of the following:  
enterpriseSecClockFail(4)  
The currently configured  
secondary clock source  
has failed.  
General traps – include warmStart and  
authenticationFailure. The device sends a  
warmStart trap after it has been reset to indicate  
that it has just reinitialized itself. The device sends  
an authenticationFailure trap when it has received  
an SNMP protocol message that has not been  
properly authenticated. These traps are set by the  
Gen Trap configuration option.  
enterpriseTestStart(5)  
A test is initiated.  
enterpriseTestClear(105)  
A test is concluded.  
Enterprise Specific traps – signify that the device  
has recognized an enterprise-specific event. See  
are set by the Entp Trap configuration option.  
Table 4-6  
SNMP Trap per Interface  
Interface Trap Meaning  
Link Traps – identify the condition of the  
communications interface, either linkDown (one of  
the communications interfaces has failed) or linkUp  
(one of the communications interfaces has just  
come up). These traps are set by the Link Trap  
configuration option. The communications  
interfaces for which these traps can be generated  
are specified by the Trap I/F configuration option.  
HDSL Network  
Up = No alarm or test  
conditions.  
Down = Alarm or test  
conditions.  
G.703 DTE  
Up = No alarm or test  
conditions, and the  
interface is enabled.  
Down = Alarm or test  
conditions, or the interface  
is disabled.  
Synchronous Data Ports  
Up = No test conditions,  
the port is assigned to a  
network interface, and both  
CTS and DSR are ON.  
Down = Test conditions,  
the port is unassigned, or  
either CTS or DSR is off.  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-11  
     
ACCULINK 336x E1 NTU  
For problems other than those listed in the table, please  
contact your service representative.  
Troubleshooting  
The E1 NTU is designed to provide you with many  
you some direction if a problem occurs.  
Table 4-7  
(1 of 2)  
Troubleshooting  
Symptom  
Possible Cause  
Solutions  
No power  
1. The power module is not securely attached.  
2. The wall receptacle has no power.  
1. Check the power module attachment.  
2. Check the wall receptacle power by plugging  
in some equipment that is known to be  
working.  
Power-Up  
Self-Test fails  
The E1 NTU has detected an internal hardware  
failure.  
Contact your field service representative.  
Message LOS on 1. Network cable problem.  
Loop1 or LOS on  
1. Check that the network cable is securely  
attached at both ends.  
Loop2 appears  
2. The far-end LTU/NTU is not transmitting.  
2. Check the far-end status.  
3. Network problem.  
3. Contact your facility provider.  
Message LOS at 1. G.703 DTE cable problem.  
DTE appears  
1. Check that the G.703 DTE cable is securely  
attached at both ends.  
2. No signal being transmitted from the DTE.  
2. Check the DTE status.  
3. The 120 ohm interface is being used and the  
RX SHIELD switch is in the EARTH position.  
3. Change the RX SHIELD switch to the OPEN  
position when using the 120 ohm interface.  
Message OOF at 1. Incompatible framing format between the  
1. Check that the framing format for the network  
interface is correct.  
Net appears  
network and the E1 NTU.  
2. Network cabling problem.  
2. Check that the network cable is securely  
attached at both ends.  
3. Facility problem.  
3. Contact your facility provider.  
Message OOF at 1. Incompatible framing format between the  
1. Check that the framing format for the G.703  
DTE interface is correct.  
DTE appears  
G.703 port on the customer premises  
equipment and the E1 NTU.  
2. G.703 DTE cabling problem.  
1. Network cable problem.  
2. Check that the G.703 DTE cable is securely  
attached at both ends.  
Message  
RAI at Net  
appears  
1. Check that your network cable is securely  
attached at both ends.  
2. Far-end LTU/NTU has detected an LOS, LOF, 2. Check the status of the far-end device.  
AIS, or EER condition on the line.  
3. Facility problem.  
3. Contact your facility provider.  
Message  
RAI at DTE  
appears  
DTE has detected an LOS, LOF, AIS, or EER  
condition.  
1. Check the status of the DTE.  
2. Check that the G.703 DTE cable is securely  
attached at both ends.  
Message  
AIS at Net  
appears  
1. Upstream LTU/NTU is transmitting an AIS.  
2. The network is transmitting an AIS.  
1. Check the status of the upstream device(s).  
2. Contact your facility provider.  
4-12  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Maintenance  
Table 4-7  
(2 of 2)  
Troubleshooting  
Symptom  
Possible Cause  
Solutions  
Message  
DTE is sending an AIS.  
Check the DTE.  
AIS at DTE  
appears  
Message EER at Facility problem.  
Contact your facility provider.  
Net appears  
BPV LED is ON  
1. Incompatible line coding format between the  
DTE and the E1 NTU.  
1. Check that the line coding format for the  
G.703 DTE interface is correct.  
2. G.703 DTE cable problem.  
2. Check that the DTE cable is securely attached  
at both ends.  
A failure message Internal E1 NTU problem.  
appears followed  
Record the 8-digit code, then contact your  
field service representative.  
by an 8-digit code  
(x x x x x x x x )  
SNMP link is  
down  
1. The SNMP manager configuration is  
mismatched with the device configuration.  
1. Check that the configurations are matched.  
2. The SNMP manager’s link layer protocol is not 2. Start the link layer protocol.  
running.  
No SNMP  
communication  
1. Cable problem.  
1. Check that the cable is securely attached at  
both ends.  
via the AUX port  
2. The link layer protocol is not running.  
2. Change the Aux Use configuration option to  
None, and then back to SNMP or Daisy (as  
appropriate).  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-13  
 
ACCULINK 336x E1 NTU  
Test Jacks  
HDSL  
NET  
E1  
E1  
LINE MON  
Lp1  
In  
In  
Six test jacks are located on the front panel  
and two monitor access points to the E1 NTU.  
Lp2  
Out  
Out  
495-14753  
Figure 4-1. E1 NTU Test Jacks  
E1  
E1  
HDSL  
NET  
Lp1  
LINE MON  
Out  
Out  
TERMINAL  
EQUIPMENT  
(DTE)  
LINE  
INTERFACE  
NTU  
CIRCUITRY  
LINE  
INTERFACE  
HDSL  
NETWORK  
E1  
E1  
HDSL  
NET  
Lp2  
Port 1  
Port 3  
Port 4  
LINE MON  
Port 2  
In  
In  
495-14754  
Figure 4-2. Test Jack Block Diagram  
Table 4-8  
Test Jack Functions  
Test Jack Name  
Function  
HDSL NET Lp1  
(HDSL Network Loop 1)  
A break-in test jack that allows a signal to be inserted by external test equipment.  
The signal is inserted and received on the HDSL (Loop 1) side of the E1 NTU.  
HDSL NET Lp2  
(HDSL Network Loop 2)  
A break-in test jack that allows a signal to be inserted by external test equipment.  
The signal is inserted and received on the HDSL (Loop 2) side of the E1 NTU.  
E1 LINE In  
A break-in test jack that allows an E1 signal to be inserted toward the E1 NTU on  
the G.703 DTE side of the E1 NTU.  
E1 LINE Out  
A break-in test jack that allows an E1 signal to be inserted toward the terminal  
equipment on the G.703 DTE side of the E1 NTU.  
E1 MON In  
(E1 Monitor In)  
A monitor jack that nonintrusively monitors the signal coming out of the terminal  
equipment on the G.703 DTE side of the E1 NTU.  
E1 MON Out  
(E1 Monitor Out)  
A monitor jack that nonintrusively monitors the signal going into the terminal  
equipment on the G.703 DTE side of the E1 NTU.  
4-14  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
       
Maintenance  
2. From the Test screen, select Rlpbk.  
Test Commands  
The test commands enable you to run loopbacks and  
test patterns on the E1 NTU, and to test the front panel  
LEDs. These tests can help you isolate areas of trouble if  
you are having problems with your E1 NTU.  
Test:  
Rlpbk Lpbk  
Ptrns  
F3  
F1  
F2  
To access all Test commands from the Test branch,  
press F2 to select Test from the top-level menu screen.  
3. From the Rem Loopback screen, press the  
Function key that corresponds to the specific  
loopback test you want to perform.  
E1 HDSL NTU  
Stat  
Test  
Cnfig  
F3  
F1  
F2  
Rem Loopback:  
DCLBUP  
DCLBDN  
F3  
NOTE  
F1  
F2  
The following procedures are  
examples only. Screen displays  
may vary depending on the  
model and configuration of the  
E1 NTU.  
The Rem Loop screen appears, where Type is  
either DCLBUP or DCLBDN.  
Rem Loop: Type  
Prt1  
Prt2 Prt3  
F3  
F1  
F2  
Remote Loopback Tests  
The Remote Loopback tests enable you to troubleshoot  
your circuit by sending the following to a far-end device:  
The DCLBUP and DCLBDN commands send the  
requested sequence out the network interface on  
the DS0 channels allocated to the port you select  
here.  
Data channel loopback up (DCLBUP) activation  
sequence to initiate a V.54 Loop 2  
Data channel loopback down (DCLBDN)  
deactivation sequence to terminate a V.54 Loop 2  
4. From the Rem Loop screen, press the desired  
Function key to select the specific port. Use the  
scroll keys, if necessary.  
You cannot perform remote loopbacks if any of the  
local loopbacks are active. If you attempt to do so, the  
error message Invld Test Combo (Invalid Test  
Combination) appears.  
After you select a port, the sequence is sent to the  
far-end device. During this time, Sending appears  
on Line 2 of the LCD, followed by Command  
Complete when the sequence is complete.  
To send a Data Channel Activation or Deactivation  
loopback sequence to the far-end device,  
During the Sending message, you can press the  
and  
keys without affecting transmission  
1. From the top-level menu screen, select Test.  
of the loopback sequence.  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-15  
     
ACCULINK 336x E1 NTU  
The Line Loopback command can be activated and  
deactivated in response to commands received over the  
network interface. The Network Interface configuration  
option NET LLB controls whether the E1 NTU responds  
to the commands transmitted on the network interface to  
Local Loopback Tests  
The Local Loopback tests enable you to conduct circuit  
testing and fault isolation for the digital line. The  
supported local loopback tests are:  
Line Loopback (LLB)  
The data port configuration option NET DCLB  
controls whether the E1 NTU responds to inband V.54  
commands to initiate DCLB for that port (see  
Payload Loopback (PLB)  
DTE Loopback (DLB)  
Repeater Loopback (RLB)  
Data Channel Loopback (DCLB)  
Data Terminal Loopback (DTLB)  
Local loopback tests can be aborted (Abort Command)  
at any time.  
No more than two local loopbacks can be active at any  
one time. An additional restriction prohibits certain  
loopbacks from running at the same time. Valid loopback  
NOTE  
DLB does not appear when the  
G.703 DTE interface is disabled.  
Table 4-9  
Valid Loopback Combinations  
LLB  
N/A  
NO  
PLB  
NO  
DLB  
YES  
YES  
N/A  
RLB  
YES  
NO  
DCLB  
NO  
DTLB  
YES  
YES  
YES  
YES  
LLB  
PLB  
N/A  
YES  
NO  
NO  
DLB  
RLB  
DCLB  
YES  
YES  
NO  
NO  
YES  
NO  
NO  
N/A  
NO  
NO  
YES  
YES  
(on separate  
ports)  
YES  
(on separate  
ports)  
DTLB  
YES  
YES  
YES  
YES  
YES  
(on separate  
ports)  
YES  
(on separate  
ports)  
4-16  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Maintenance  
Starting a Line Loopback  
Starting a Payload Loopback  
The Line Loopback command (LLB) loops the  
received signal on the network interface back to the  
network without change. All ones are transmitted on the  
G.703 DTE port for the DS0 channels allocated to the  
network interface. All ones are also transmitted to each  
synchronous data port allocated to the network interface.  
The Payload Loopback command (PLB) loops the  
received signal on the network interface back to the  
network. The signal is looped back as close to the G.703  
DTE port as possible (after it has passed through the  
framing circuitry of the E1 NTU). Therefore, framing  
CRCs and BPVs are corrected. All ones are transmitted on  
the G.703 DTE port for the DS0 channels allocated to the  
network interface. All ones are also transmitted to each  
synchronous data port allocated to the network interface.  
NTU  
AIS  
DTE  
(G.703)  
LLB  
HDSL  
NTU  
AIS  
DTE  
(G.703)  
PLB  
HDSL  
LINE LOOPBACK (LLB)  
495-14758  
PAYLOAD LOOPBACK (PLB)  
To perform a Line loopback,  
495-14759  
1. From the top-level menu screen, select Test.  
2. From the Test screen, select Lpbk.  
To perform a Payload loopback,  
1. From the top-level menu screen, select Test.  
2. From the Test screen, select Lpbk.  
Test:  
Rlpbk Lpbk  
Ptrns  
Test:  
F3  
F1  
F2  
Rlpbk Lpbk  
Ptrns  
F3  
F1  
F2  
3. From the Loopback screen, select LLB.  
3. From the Loopback screen, select PLB.  
Loopback:  
Abort LLB  
PLB  
Loopback:  
F3  
F1  
F2  
Abort LLB  
PLB  
F3  
F1  
F2  
Test Started appears on Line 2. If a line loopback  
is already in progress, the Already Active  
message appears. If an invalid combination of  
loopbacks is in progress, the error message Invld  
loopback test combinations).  
Test Started appears on Line 2. If a Payload  
loopback is already in progress, the Already  
Active message appears. If an invalid combination  
of loopbacks is in progress, the error message  
valid loopback test combinations).  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-17  
   
ACCULINK 336x E1 NTU  
4. Select DLB.  
Starting a DTE Loopback  
The DTE Loopback command (DLB) loops the  
received signal on the G.703 DTE port back to the DTE  
without change. All ones are inserted into the DS0  
channels allocated to the G.703 DTE port.  
Loopback:  
LLB  
PLB  
DLB  
F3  
F1  
F2  
A DTE loopback can be activated and deactivated  
based on the state of an external contact on the G.703  
DTE port. If this option is enabled with the DTE Interface  
configuration option Extrn DLB, closing the contact  
activates a DLB. The DLB remains active until the  
section in Appendix D, Pin Assignments, for more  
information.  
Test Started appears on Line 2. If a DTE  
loopback is already in progress, the Already  
Active message appears. If an invalid combination  
of loopbacks is in progress, the error message  
valid loopback test combinations).  
NTU  
Starting a Repeater Loopback  
AIS  
DTE  
(G.703)  
DLB  
HDSL  
The Repeater Loopback command (RLB) loops the  
signal being sent to the network back to the G.703 DTE  
and data ports. The signal is looped back as close to the  
network interface as possible (after it has passed through  
the framing circuitry of the E1 NTU). Therefore, framing  
CRCs and BPVs are corrected. All ones are transmitted to  
the network interface.  
DTE LOOPBACK (DLB)  
495-14760  
To perform a DTE loopback,  
1. From the top-level menu screen, select Test.  
2. From the Test screen, select Lpbk.  
NTU  
AIS  
DTE  
(G.703)  
RLB  
HDSL  
Test:  
Rlpbk Lpbk  
REPEATER LOOPBACK (RLB)  
Ptrns  
495-14761  
F3  
F1  
F2  
To perform a Repeater loopback,  
1. From the top-level menu screen, select Test.  
2. From the Test screen, select Lpbk.  
3. From the Loopback screen, press the  
the DLB selection appears on the screen.  
key until  
Loopback:  
Abort LLB  
Test:  
Rlpbk Lpbk  
PLB  
Ptrns  
F3  
F1  
F2  
F3  
F1  
F2  
4-18  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
     
Maintenance  
3. From the Loopback screen, press the  
the RLB selection appears on the screen.  
key until  
To perform a Data Channel loopback,  
1. From the top-level menu screen, select Test.  
2. From the Test screen, select Lpbk.  
Loopback:  
Abort LLB  
PLB  
F3  
F1  
F2  
Test:  
Rlpbk Lpbk  
Ptrns  
F3  
F1  
F2  
4. Select RLB.  
Loopback:  
3. From the Loopback screen, press the  
key until  
PLB  
DLB  
RLB  
the DCLB selection appears on the screen.  
F3  
F1  
F2  
Loopback:  
Abort LLB  
PLB  
Test Started appears on Line 2. If a Repeater  
loopback is already in progress, the Already  
Active message appears. If an invalid combination  
of loopbacks is in progress, the error message  
loopback test combinations).  
F3  
F1  
F2  
4. Select DCLB.  
Loopback:  
Starting a Data Channel Loopback  
DLB  
RLB  
DCLB  
The Data Channel Loopback command (DCLB) loops  
the data received from the network interface, for all DS0  
channels allocated to the selected port, back to the  
network. The loopback occurs after the data passes  
through the port circuitry but before it is sent out the data  
port. All ones are inserted into the DS0 channels allocated  
to that port.  
F3  
F1  
F2  
5. From the DCLB screen, press the Function key for  
the port for which you want to perform the data  
channel loopback. Use the scroll keys, if  
necessary.  
NTU  
DATA  
PORTS  
(1 - 4)  
AIS  
DCLB  
HDSL  
Loopback: DCLB  
Prt1  
Prt2  
Prt3  
F3  
F1  
F2  
DATA CHANNEL LOOPBACK (DCLB)  
495-14775  
Test Started appears on Line 2. If a Data Channel  
loopback is already in progress, the Already  
Active message appears. If an invalid combination  
of loopbacks is in progress, the error message  
valid loopback test combinations).  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-19  
   
ACCULINK 336x E1 NTU  
5. From the DTLB screen, press the Function key for  
the port for which you want to perform the data  
terminal loopback. Use the scroll keys, if  
necessary.  
Starting a Data Terminal Loopback  
The Data Terminal Loopback command (DTLB) loops  
the data received from the selected port, for all DS0  
channels allocated to the port, back out of the port. This  
loopback occurs after the data passes through the port  
circuitry but before it reaches the E1 framer. All ones are  
transmitted to that port.  
Loopback: DTLB  
Prt1  
Prt2  
Prt3  
F3  
F1  
F2  
NTU  
DATA  
PORTS  
(1 - 4)  
AIS  
DTLB  
HDSL  
Test Started appears on Line 2. If a Data  
Terminal loopback is already in progress, the  
Already Active message appears. If an invalid  
combination of loopbacks is in progress, the error  
message Invld Test Combo appears (see  
DATA TERMINAL LOOPBACK (DTLB)  
496-14774-01  
To perform a Data Terminal loopback,  
Aborting Loopbacks  
1. From the top-level menu screen, select Test.  
2. From the Test screen, select Lpbk.  
The Abort Loopback command stops all loopback tests  
or any selected loopback test currently active on the E1  
NTU.  
To abort one or more loopback tests,  
Test:  
Rlpbk Lpbk  
Ptrns  
1. From the top-level menu screen, select Test.  
2. From the Test screen, select Lpbk.  
F3  
F1  
F2  
Test:  
Rlpbk Lpbk  
3. From the Loopback screen, press the  
key until  
Ptrns  
the DTLB selection appears on the screen.  
F3  
F1  
F2  
4. Select DTLB.  
Loopback:  
3. From the Loopback screen, select Abort.  
RLB  
DCLB DTLB  
F3  
F1  
F2  
Loopback:  
Abort LLB  
PLB  
F3  
F1  
F2  
4-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
     
Maintenance  
4. From the Loopback Abort screen, press the  
desired Function key to abort All or one specific  
loopback test. Use the scroll keys, if necessary.  
Test Patterns  
Use the Test Pattern commands to send, monitor, and  
abort test patterns. Available test patterns are:  
32767 – A pseudo-random bit sequence (PRBS)  
Loopback: Abort  
that is 32,767 bits long (on the network only). This  
All  
LLB  
PLB  
15  
is a PRBS 2 –1 test.  
F3  
F1  
F2  
511 – A pseudo-random bit sequence (PRBS) that is  
511 bits long (on the data ports only). This is a  
9
PRBS 2 –1 test.  
If you select ALL, LLB, PLB, DLB, or RLB, skip  
Step 5.  
1-in-8 – A test pattern consisting of a one (1)  
followed by seven zeros (on the network only).  
5. From the Abort screen, press the Function key that  
corresponds to the port for which you want to  
abort the test. Use the scroll keys, if necessary.  
QRSS – A quasi-random signal source  
approximating live data that can be monitored for  
logic errors (on the data ports only).  
Sending Test Patterns  
Abort: Test Name  
Prt1  
Prt2  
Prt3  
Use the Send command to start transmission of a test  
pattern.  
F3  
F1  
F2  
Only one test pattern can be active at a time on one  
combinations. Valid combinations are identified by YES.  
When abort is complete, the message Command  
Complete appears on the Abort screen.  
To send a test pattern,  
1. From the top-level menu screen, select Test.  
2. From the Test screen, select Ptrns.  
NOTE  
Be careful when selecting a  
specific loopback test to abort. If  
you mistakenly choose to abort a  
loopback test that is not currently  
running, a Command Complete  
message will still display and the  
loopback that is currently active  
will still be running. You can use  
the TStat branch of the menu to  
view the test status to determine if  
the abort was successful.  
Test:  
Rlpbk Lpbk  
Ptrns  
F3  
F1  
F2  
3. From the Patterns screen, select Send.  
Patterns:  
Abort Send  
Mon  
F3  
F1  
F2  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-21  
     
ACCULINK 336x E1 NTU  
4. From the Patterns Send screen, press F1 to send a  
32767 pattern, F2 to send a 511 pattern, F3 to send  
The Test Started screen appears.  
a 1-in-8 pattern, or press the  
key and the  
appropriate Function key to send a QRSS pattern.  
Send: Name and Dest  
Test Started  
Patterns: Send  
F3  
F1  
F2  
32767 511  
1in8  
F3  
F1  
F2  
If the E1 NTU is already sending the test pattern  
you selected, the message Already active appears.  
If you selected an incompatible test pattern  
combination, the message Invld Test Combo  
If you send a 32767 or 1-in-8 pattern, skip Step 5.  
5. From the Send screen, press the Function key that  
corresponds to the port for which you want to send  
a test pattern. Use the scroll keys, if necessary.  
Send: Name  
Prt1  
Prt2  
Prt3  
F3  
F1  
F2  
Table 4-10  
Valid Send Test Pattern Combinations  
32767 (Network)  
511 (Port)  
1-in-8 (Network)  
QRSS (Port)  
32767 (Network)  
N/A  
NO  
NO  
NO  
NO  
NO  
511 (Port)  
YES (on  
YES (on  
separate ports)  
separate ports)  
1 in 8 (Network)  
QRSS (Port)  
NO  
NO  
NO  
N/A  
NO  
NO  
YES (on  
separate ports)  
YES (on  
separate ports)  
4-22  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Maintenance  
5. From the Monitor screen, press the Function key  
that corresponds to the port for which you want to  
monitor a QRSS or 511 test pattern. Use the scroll  
keys, if necessary.  
Monitoring Test Patterns  
Use the Monitor command to monitor 32767, QRSS, or  
511 test patterns.  
This command provides the number of errors detected  
in the test pattern (5 digits, maximum 99999).  
Monitor: Name  
To monitor a 32767, QRSS, or 511 test pattern,  
1. From the top-level menu screen, select Test.  
2. From the Test screen, select Ptrns.  
Prt1  
Prt2  
Prt3  
F3  
F1  
F2  
The Monitor screen appears with the error count.  
If the maximum of 99999 is exceeded, OvrFlw  
appears instead of the count. If the receiver loses  
synchronization while the monitor is active, No  
Sync appears.  
Test:  
Rlpbk Lpbk  
Ptrns  
F3  
F1  
F2  
Aborting Test Patterns  
Use the Abort command to stop all test patterns or any  
selected test pattern active on the E1 NTU.  
3. From the Patterns screen, select Mon.  
To abort test patterns,  
Patterns:  
Abort Send  
Mon  
1. From the top-level menu screen, select Test.  
2. From the Test screen, select Ptrns.  
F3  
F1  
F2  
Test:  
Rlpbk Lpbk  
4. From the Patterns Mon screen, press F1 for 32767,  
F2 for QRSS, or F3 for 511.  
Ptrns  
F3  
F1  
F2  
Patterns: Mon  
32767 QRSS 511  
3. From the Patterns screen, select Abort.  
F3  
F1  
F2  
Patterns:  
Abort Send  
If you monitor a 32767 pattern, skip Step 5.  
Mon  
F3  
F1  
F2  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-23  
   
ACCULINK 336x E1 NTU  
4. From the Patterns Abort screen, press the desired  
Function key to abort either All active test  
patterns, active Send test patterns, or the active  
Monitor (Mon) test pattern.  
Lamp Test  
Use the Lamp Test commands to start and stop a test of  
the E1 NTU front panel LCD and LEDs.  
Patterns: Abort  
Starting a Lamp Test  
All  
Send  
Mon  
To start a Lamp test,  
F3  
F1  
F2  
1. From the top-level menu screen, select Test.  
2. From the Test screen, press the  
key until the  
If you select All, the E1 NTU terminates all active  
test patterns and displays the message Command  
Complete. Skip Step 5.  
Lamp selection appears on the screen.  
Test:  
Rlpbk Lpbk  
Ptrns  
NOTE  
Be careful when selecting a specific  
test pattern to abort. If you mistakenly  
choose to abort a test pattern that is  
not currently running, a Command  
Complete message still displays and  
the test pattern currently active still  
runs. You can use the TStat branch of  
the menu to view the test status to  
determine if the abort was successful.  
F3  
F1  
F2  
3. From the Test screen, select Lamp.  
Test:  
Lpbk Ptrns Lamp  
F3  
F1  
F2  
5. From the Abort screen, press the Function key that  
corresponds to the network or port for which you  
want to abort a test pattern. Use the scroll keys, if  
necessary.  
4. From the Lamp Test screen, select Start.  
Lamp Test:  
Abort Start  
Abort: Send or Mon  
NET  
Prt1  
Prt2  
F3  
F1  
F2  
F3  
F1  
F2  
The E1 NTU terminates the selected test pattern  
and displays the message Command Complete.  
4-24  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
     
Maintenance  
5. The following screens alternately appear on the  
LCD until you press a Function key to return to  
the Lamp Test screen. In addition, all LEDs blink.  
Displaying E1 NTU Test Status  
Use the Test Status command to display the active tests  
for the E1 NTU. Status messages that can display on the  
To display test status,  
1. From the top-level menu screen, select Stat.  
F3  
F1  
F2  
E1 HDSL NTU  
Stat  
Test  
Cnfig  
0123456789 : ; < = > ?  
@ABCDEFGHIJKLMNO  
F3  
F1  
F2  
F3  
F1  
F2  
2. From the Status screen, press the  
TStat selection appears on the screen.  
key until the  
6. When you are satisfied that all LEDs are lighting  
and the LCD is functioning properly, abort the  
Lamp test from the Lamp Test screen. If there is  
no activity on the E1 NTU front panel for five  
minutes, the Device Health and Status screen  
appears automatically. However, the Lamp test  
remains active until it is aborted.  
Status:  
HDSL DevHS STest  
F3  
F1  
F2  
Aborting a Lamp Test  
3. Select TStat.  
To abort the Lamp test,  
Status:  
STest Perf  
1. Display the Lamp Test screen. To do this when the  
LCD is alternating the Lamp test screens, press  
any Function key. Otherwise, follow Steps 1  
through 3 for starting a Lamp test.  
TStat  
F3  
F1  
F2  
The Test Status screen appears showing you what  
tests are active for the E1 NTU.  
Lamp Test:  
Abort Start  
F3  
F1  
F2  
2. From the Lamp Test screen, select Abort.  
Lamp Test:  
Abort Start  
F3  
F1  
F2  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-25  
     
ACCULINK 336x E1 NTU  
Table 4-11  
Test Status Messages  
Message  
No Test Active  
LLB Test Active  
PLB Test Active  
DLB Test Active  
RLB Test Active  
DCLB on Port n  
DTLB on Port n  
1–8 Test Active  
32767 Tst Active  
QRSS on Port n  
511 on Port n  
Description  
No tests are currently active.  
The network interface is in Line loopback.  
The network interface is in Payload loopback.  
The G.703 DTE port is in DTE loopback.  
The G.703 DTE port is in Repeater loopback.  
Port n is in a Data Channel loopback.  
Port n is in a Data Terminal loopback.  
A 1-in-8 test pattern is being sent on the network interface.  
A 32767 test pattern is being sent on the network interface.  
A QRSS test pattern is being sent to the network on the channels allocated to port n.  
A 511 test pattern is being sent to the network on the channels allocated to port n.  
A QRSS test pattern is being monitored on the channels allocated to port n.  
A 32767 test pattern is being monitored on the network interface.  
A 511 test pattern is being monitored on the channels allocated to port n.  
The G.703 DTE port is being held in DTE loopback by the external contact.  
The Lamp test is currently active.  
Mon QRSS, Port n  
Mon 32767, Net  
Mon 511, Port n  
DLB Test, Extrn  
Lamp Test Active  
4-26  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Front Panel Menu  
A
NOTE  
Some selections are not available  
on 1-port and 2-port E1 NTUs.  
E1 HDSL NTU  
Stat  
Test  
Cnfig  
Ctrl  
Rel LED ClrReg Reset CID DL  
Rlpbk  
Lpbk  
Abort  
32767  
Ptrns  
Lamp  
Mon  
HDSL DevHs STest Perf TStat LED ID  
Send  
E1 Prtn  
E1 HDSL DTE Prt1 Prt2 Prt3 Prt4  
1in8  
511 QRSS  
NET  
DTE  
Prtn  
DCLBUP DCLBDN  
Cur 24Tot Intvl  
Near Far  
32767 QRSS  
DTE  
Prt1  
Prt2  
Prt4  
511  
Prt3  
Near Far  
E1  
Cur 24Tot Intvl  
Cur 24Tot Intvl  
Lpn  
Abort PLB RLB DTLB  
LLB DLB DCLB  
Load Edit Area From:  
Cur 8Tot Intvl  
Activ Cust1 Cust2 Fact  
Choose Function:  
Edit  
Save  
Activ Cust1 Cust2  
DTE  
Port  
NET  
Chan  
Gen  
User  
Alarm  
SNMP  
Dsply Clear DTE Prt1 Prt2 Prt3 Prt4  
Gen  
Trap  
Copy  
Port Select :  
All Prt1 Prt2 Prt3 Prt4  
Prt1  
Prt2  
Prt3  
Prt4  
495-14756  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A-1  
   
Technical Specifications  
B
Overview  
The technical specifications for the Models 3360,  
Table B-1  
(1 of 2)  
Models 3360/3364/3365 NTUs Technical Specifications  
Specifications  
Criteria  
POWER REQUIREMENTS  
Typical:  
AC Power Module  
Refer to the labeling on the ac power module for input requirements  
Optional:  
+24 Vdc  
+20 Vdc to +32 Vdc, 0.75A  
–38 Vdc to –60 Vdc, 0.375A  
–38 Vdc to –60 Vdc, 0.375A  
48 Vdc  
48 Vdc Redundant  
POWER CONSUMPTION AND  
DISSIPATION  
22.0 watts, 75.0 Btu per hour at 115 volts (ac power); 18.0 watts, 61.5 Btu per  
hour at +24 and 48 Vdc (dc power)  
G.703 DTE INTERFACE  
Physical Interface  
BNC pair for 75 ohm coaxial cables (unbalanced) or  
DB15 socket for 120 ohm twisted pair (balanced)  
CRC-4, non-CRC-4  
Framing Format  
Coding Format  
AMI, HDB3  
HDSL Network INTERFACE  
Physical Interface  
Framing Format  
Coding Format  
RJ48C for HDSL  
CRC-4, non-CRC-4  
HDB3  
PORT INTERFACE  
Standards  
Rates  
EIA 530A, V.35, RS-449, X.21  
Nx64 kbps  
3360-A2-GB20-20  
December 1996  
B-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
ACCULINK 336x E1 NTU  
Table B-1  
(2 of 2)  
Models 3360/3364/3365 NTUs Technical Specifications  
Specifications  
Criteria  
APPROVALS  
CISPR 22 Class A compliant  
CLOCKING SOURCES  
HDSL Network interface, synchronous data port, internal clock, G.703 DTE  
interface, or (for 2-port and 4-port E1 NTUs) external clock  
PHYSICAL DIMENSIONS  
Height  
Models 3360 and 3364 NTUs = 3.90 inches (10.0 cm)  
Model 3365 NTU = 2.13 inches (5.4 cm)  
7.63 inches (19.4 cm)  
Width  
Depth  
12.13 inches (30.8 cm)  
WEIGHT  
Models 3360 and 3364 NTUs = 3.6 pounds (1.7 kg)  
Model 3365 NTU = 2.4 pounds (1.1 kg)  
ENVIRONMENT  
Operating Temperature  
Storage Temperature  
Relative Humidity Shock and  
Vibration  
32°F to 122°F (0°C to 50°C)  
4°F to 158°F (20°C to 70°C)  
5% – 95% (noncondensing)  
Withstands normal shipping and handling  
B-2  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Configuration Options  
C
General Configuration Options  
Overview  
The General configuration options configure clocks  
The E1 NTU configuration option tables contain a list  
of all configuration options and their selectable options.  
The configuration options are arranged into functional  
groups:  
User Interface Configuration Options  
The User Interface configuration options configure  
DTE Interface Configuration Options  
The DTE Interface configuration options configure  
the G.703 DTE interface on the E1 NTU  
Alarm Configuration Options  
The Alarm configuration options specify how alarm  
Port Configuration Options  
SNMP Configuration Options  
The Port configuration options configure the  
The SNMP Configuration Options configure the  
Network Interface Configuration Options  
The Network Interface configuration options  
configure the HDSL Network interface on the  
The configuration tables include a description of each  
configuration function and its selectable options. In the  
tables, the top line of each configuration option entry  
indicates the factory default setting.  
Channel Configuration Options  
The Channel configuration options configure the  
G.703 DTE and synchronous data port channel  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C-1  
     
ACCULINK 336x E1 NTU  
DTE Interface  
Configuration Options  
Table C-1  
DTE Interface Configuration Options  
DTE Port: Enab  
Next Enab Disab Prev  
G.703 DTE Port. Enables the use of the G.703 DTE port.  
Enab – Allows the use of the G.703 DTE interface.  
Disab – Prohibits the use of the G.703 DTE interface.  
NOTE: When this configuration option is disabled, you cannot display or configure any other DTE Interface  
configuration options and TS16 is set to data. If a clock source configuration option is set to DTE, it is changed  
to NET.  
DTE Frame: noCRC  
Next CRC4 noCRC Prev  
DTE Line Framing Format. Designates the framing format for the G.703 DTE interface.  
CRC4 – Configures for the CRC4 framing format.  
noCRC – Configures for the non-CRC4 framing format.  
DTE Coding: HDB3  
Next AMI HDB3 Prev  
DTE Line Coding. Designates the line coding format to be used on the G.703 DTE interface.  
AMI – Uses the Alternate Mark Inversion coding format.  
HDB3 – Uses the High Density Bipolar 3 coding format.  
Extrn DLB: Disab  
Next Enab Disab Prev  
DTE Loopback on External Contact. Allows the initiation and termination of a DTE Loopback (DLB) by an external  
Enab – Allows the E1 NTU to begin a DLB when the external contact is closed (if the current E1 NTU state allows a DLB  
to be performed). If the E1 NTU is already performing a DLB, closing the contact will have no effect. Opening the contact  
takes the E1 NTU out of DLB. The E1 NTU remains in DLB as long as the contact remains closed.  
Disab – Prevents the state of the external contact from affecting the operation of DLB.  
Send Ones: Enab  
Next Enab Disab Prev  
Send All Ones on DTE Failure. Specifies the action to take on the signal transmitted to the network when a valid signal  
cannot be recovered from the G.703 DTE interface (due to an LOS, OOF, or AIS condition).  
Enab – Sends all ones on the DS0 channels allocated to the network interface when an LOS, AIS, or OOF condition  
occurs on the G.703 DTE interface.  
Disab – Passes the data unchanged to the network interface channels.  
C-2  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Configuration Options  
Port Configuration Options  
Table C-2  
(1 of 4)  
Port Configuration Options  
Port Type: E530  
Next E530 V.35 RS449 X.21 Prev  
Data Port Type. Allows selection of the data port interface type.  
E530 – Configures the port as an EIA 530A compatible interface. EIA 530A DTEs can be directly connected to a port  
connector on the back of the E1 NTU.  
V.35 – Configures the port as a V.35 compatible interface. V.35 DTEs can be connected to a port connector using an  
EIA 530A-to-V.35 adapter cable.  
RS449 – Configures the port as an RS449 compatible interface. RS449 DTEs can be connected to a port connector using  
an EIA 530A-to-RS449 adapter cable.  
X.21 – Configures the port as an X.21 compatible interface. X.21 DTEs can be connected to a port connector using an  
EIA 530A-to-X.21 adapter cable.  
NOTE: If this configuration option is set to X.21, you must set the All Ones configuration option to RTS or Disab.  
Net DCLB: Disab  
Next Enab Disab Prev  
Network Initiated DCLB. Allows the initiation and termination of a Data Channel Loopback (V.54 loop 2) by the receipt of a  
V.54 DCLB-actuate sequence or DCLB-release sequence from the network or far-end device.  
Enab – Allows the E1 NTU to begin a DCLB for this port when it receives a DCLB-actuate sequence (if the current E1  
NTU state allows a DCLB to be performed). Receiving a DCLB-release sequence terminates the DCLB.  
Disab – Ignores the DCLB-actuate and DCLB-release sequences for this port.  
Port LB: Disab  
Next Disab DTLB DCLB Both Prev  
Port (DTE) Initiated Loopbacks. Allows the initiation and termination of a local Data Terminal Loopback (DTLB) or remote  
Data Channel Loopback (DCLB) by the DTE connected to this port. (DTLB is equivalent to a V.54 loop 3, and DCLB is  
equivalent to a V.54 loop 2.) Control of these loopbacks is through the DTE interchange circuits as specified by the V.54  
standard.  
Disab – Disables control of local DTLBs and remote DCLBs by the DTE connected to this port.  
DTLB – Gives control of the local DTLBs for this port to the DTE attached to this port. This loopback is controlled by the  
Local Loopback interchange circuit LL (CCITT 141).  
DCLB – Gives control of the remote DCLBs for the far-end port connected to this port to the DTE attached to this port.  
This loopback is controlled by the Remote Loopback interchange circuit RL (CCITT 140). The far-end equipment must  
support in-band V.54 loopbacks.  
Both – Gives control of local DTLBs and remote DCLBs to the DTE connected to this port.  
3360-A2-GB20-20  
December 1996  
C-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
ACCULINK 336x E1 NTU  
Table C-2  
(2 of 4)  
Port Configuration Options  
All Ones: Both  
Next Disab DTR RTS Both Prev  
Send All Ones on Data Port Not Ready. Specifies the conditions on the data port that determine when valid data is not  
being sent from the DTE. When this condition is detected, all ones are sent to the network on the DS0 channels allocated  
to the port.  
Disab – Disables the monitoring of interchange circuits from the DTE connected to this port.  
DTR – Monitors the DTE Ready interchange circuit CD (CCITT 108/1/2). When DTR is interrupted, all ones are sent to  
the network.  
RTS – Monitors the Request-to-Send interchange circuit CA (CCITT 105). When RTS is interrupted, all ones are sent to  
the network.  
Both – Monitors both DTR and RTS. If either is interrupted, all ones are sent to the network.  
NOTE: If the Port Type configuration option is set to X.21, set this configuration option to RTS or Disab.  
Rcv RAI: Halt  
Next None Halt Prev  
Action on Network RAI Alarm. Specifies the action taken on this port when a Remote Alarm Indication (RAI) is received  
on the network interface.  
None – Makes the data port unaffected by RAIs received on the network interface.  
Halt – Stops the transmission of data on the port and disables the data port when RAIs are received on the network  
interface. When RAIs are received, all ones are sent on the Received Data interchange circuit BB (CCITT 104). The  
Clear-to-Send interchange circuit CB (CCITT 106) is interrupted.  
Tx Clock: Int  
Next Int Ext Prev  
Data Port Transmit Clock. Specifies whether the transmitted data for the port is clocked using an internal clock provided  
by the E1 NTU (synchronized to the clock source specified by the clock source configuration options in the General  
configuration option group) or an external clock provided by the DTE connected to the port. When an external clock is  
used, it must be synchronized to the same clock source as the E1 NTU.  
Int – Indicates the clock is provided internally by the E1 NTU on the TXC interchange circuit DB (CCITT 114).  
Ext – Indicates the clock is provided externally by the DTE on the XTXC interchange circuit DA (CCITT 113). Use this  
selection when either the primary or secondary clock source is set to this data port.  
InvertTxC: Disab  
Next Enab Disab Prev  
Invert Transmit Clock. Specifies whether the clock supplied by the E1 NTU on the TXC interchange circuit DB  
(CCITT 114) is phase inverted with respect to the Transmitted Data interchange circuit BA (CCITT 103). This  
configuration option is useful when long cable lengths between the E1 NTU and the DTE are causing data errors.  
Enab – Indicates TXC supplied by the E1 NTU on this port is phase inverted.  
Disab – Indicates TXC supplied by the E1 NTU on this port is not phase inverted.  
InvrtData: Disab  
Next Enab Disab Prev  
Invert Transmitted and Received Data. Specifies whether the port’s transmitted data and received data are logically  
inverted before being transmitted or received. This configuration option is useful for applications where HDLC data is  
being transported. Inverting the data ensures that the density requirements for the network interface are met.  
Enab – Indicates the transmitted data and received data for this port are inverted.  
Disab – Indicates the transmitted data and received data for this port are not inverted.  
C-4  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Configuration Options  
Table C-2  
(3 of 4)  
Port Configuration Options  
EDL: Disab  
Next Enab Disab Prev  
Embedded Data Link. Specifies whether Embedded Data Link (EDL) is enabled for a particular port. If EDL is enabled,  
then 8 kbps of the total bandwidth allocated for this port is not available to the synchronous data port. For example, if the  
port rate is 256 kbps (4 DS0 channels allocated) and EDL is enabled, then only 248 kbps is available to the port. EDL  
provides the following: detection of frame synchronization, CRC of the data stream (excluding the 8 kbps EDL), and an  
in-band data link (4 kbps) between the local and remote units. The 4 kbps in-band data link can be used for performance  
report messages and as a management link for SNMP.  
Enab – Indicates the port’s EDL is enabled.  
Disab – Indicates the port’s EDL is disabled.  
NOTE: This configuration option is only available on 2-port and 4-port E1 NTUs.  
NOTE: If the local E1 NTU’s EDL is enabled, then the remote E1 NTU’s EDL must also be enabled.  
NOTE: EDL is not recommended for networks in which data is examined for routing purposes (e.g., frame relay, x.25).  
Err Rate: 10E-4  
Next 10E-4 10E-5 10E-6 10E-7 10E-8 10E-9 Prev  
Port Excessive Error Rate Threshold. Sets the error rate threshold that determines when an Excessive Error Rate (EER)  
condition is declared for a particular port. The error rate selected by this configuration option is determined by the ratio of  
the number of CRC5 errors to the total number of bits received over a set period of time.  
10E-4 – 10E-4 Threshold. For example, at 1984 kbps, EER is declared if more than 1,983 CRC5 errors are detected in a  
10-second period. It is cleared with less than 1,984 errors in ten seconds.  
10E-5 – 10E-5 Threshold. For example, at 1984 kbps, EER is declared if more than 1,189 CRC5 errors are detected in a  
60-second period. It is cleared with less than 1,190 errors in sixty seconds.  
10E-6 – 10E-6 Threshold. For example, at 1984 kbps, EER is declared if more than 119 CRC5 errors are detected in a  
60-second period. It is cleared with less than 120 errors in sixty seconds.  
10E-7 – 10E-7 Threshold. For example, at 1984 kbps, EER is declared if more than 11 CRC5 errors are detected in a  
60-second period. It is cleared with less than 12 errors in sixty seconds.  
10E-8 – 10E-8 Threshold. For example, at 1984 kbps, EER is declared if more than 53 CRC5 errors are detected in three  
15-minute intervals. It is cleared with less than 54 errors in three 15-minute intervals.  
10E-9 – 10E-9 Threshold. For example, at 1984 kbps, EER is declared if more than 5 CRC5 errors are detected in three  
15-minute intervals. It is cleared with less than 6 errors in three 15-minute intervals.  
NOTE: This configuration option is only available on 2-port and 4-port E1 NTUs.  
NOTE: This configuration option is not available if EDL is disabled.  
Near-end: Disab  
Next Disab Maint Send Both Prev  
Near-End Performance Statistics. Specifies whether the E1 NTU will maintain near-end performance statistics and send  
performance report messages (PRMs) for a particular port.  
Disab – Disables near-end performance statistics and does not send PRMs.  
Maint – Maintains near-end performance statistics for this port.  
Send – Sends PRMs over the port’s EDL every second. Each PRM contains the performance statistics for the previous  
4 seconds.  
Both – Maintains near-end performance statistics and sends PRMs over the port’s EDL.  
NOTE: This configuration option is only available on 2-port and 4-port E1 NTUs.  
NOTE: This configuration option is not available if EDL is disabled.  
NOTE: If the local E1 NTU is configured to send near-end performance statistics, then the remote device must be  
configured to maintain far-end performance statistics.  
3360-A2-GB20-20  
December 1996  
C-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ACCULINK 336x E1 NTU  
Table C-2  
(4 of 4)  
Port Configuration Options  
Far-end: Disab  
Next Disab Maint Prev  
Far-End Performance Statistics. Specifies whether to monitor for far-end performance report messages (PRMs) and  
maintain far-end performance registers for a particular port.  
Disab – Disables far-end performance statistics.  
Maint – Monitors the port’s EDL for PRMs and maintains far-end performance statistics.  
NOTE: This configuration option is only available on 2-port and 4-port E1 NTUs.  
NOTE: This configuration option is not available if EDL is disabled.  
NOTE: If the local E1 NTU is configured to maintain far-end performance statistics, then the remote device must be  
configured to send near-end performance statistics.  
Mgmt Link: Disab  
Next Disab SNMP Prev  
EDL Management Link. Specifies whether the EDL management link is enabled for a particular port. Selecting SNMP  
allows SNMP management traffic to flow over the 4 kbps in-band data link provided by EDL.  
Disab – Disables the port’s EDL management link.  
SNMP – Enables the port’s EDL management link.  
NOTE: This configuration option is only available on 2-port and 4-port E1 NTUs.  
NOTE: This configuration option is not available if EDL is disabled or FDL is enabled for SNMP.  
NOTE: If the local E1 NTU’s EDL is enabled, then the remote device’s EDL must also be enabled.  
C-6  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Configuration Options  
Network Interface  
Configuration Options  
Table C-3  
Network Interface Configuration Options  
HDSL Mode: NTU  
Next NTU LTU Prev  
HDSL Mode. Specifies whether the operating mode is Network Termination Unit (NTU) or Line Termination Unit (LTU). In  
a poll/response environment, the LTU serves as the control unit that polls the NTU and controls such items as the  
distribution of payload data, start-up procedures, and timing references.  
NTU – Configures for the NTU mode.  
LTU – Configures for the LTU mode.  
NET Frame: noCRC  
Next CRC4 noCRC Prev  
Network Line Framing Format. Designates the framing format for the HDSL Network interface.  
CRC4 – Configures for the CRC4 framing format.  
noCRC – Configures for the non-CRC4 framing format.  
Mgmt Link: Disab  
Next Disab SNMP Prev  
FDL Management Link. Specifies whether Facility Data Link (FDL) is enabled. Selecting SNMP allows SNMP  
management traffic to flow over the 4 kbps data link provided by FDL. Running SNMP over FDL requires an end-to-end  
FDL connection and cannot be terminated within the network.  
Disab – Disables the FDL Management Link.  
SNMP – Enables the FDL Management Link for SNMP.  
NOTE: This configuration option is not available if EDL is enabled for SNMP.  
NOTE: If the local E1 NTU’s FDL is enabled for SNMP, the remote E1 NTU’s FDL must also be enabled for SNMP.  
HDSL: Disab  
Next Disab Maint Prev  
HDSL Performance Statistics. Specifies whether to monitor local HDSL performance statistics for each loop and maintain  
Loop 1 (Lp1) and Loop 2 (Lp2) performance registers.  
Disab – Disables Lp1 and Lp2 performance statistics.  
Maint – Maintains Lp1 and Lp2 performance statistics.  
Circuit Ident:  
Next Edit Clear Prev  
Network Circuit Identifier. Specifies the transmission vendor’s circuit identifier for the purpose of facilitating  
troubleshooting. The network circuit identifier is an ASCII text string that may be up to 255 characters in length.  
Edit – Allows you to edit and/or display the network circuit identifier using the generic text string entry screen.  
Clear – Allows you to clear the network circuit identifier. The network circuit identifier will be set to a null string.  
3360-A2-GB20-20  
December 1996  
C-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
ACCULINK 336x E1 NTU  
Channel Configuration  
Options  
The Channel configuration options are divided into two  
tables as follows:  
NOTE  
DTE and data port configuration  
options. For information about the  
operation of Display and Clear,  
refer to the Configuring DS0  
Operation.  
Data Port Channel Configuration Options  
Table C-4  
DTE Channel Configuration Options  
DTE Channels:  
TS16 Assign  
G.703 DTE Channel. Allows the selection of time-slot 16 (TS16) for signaling information or assigns DS0 channels from  
the G.703 DTE interface to DS0 channels on the network interface.  
TS16 – Allows the selection of TS16 for signaling information (see the TS16 configuration option below).  
Assign – Allows the assignment of DS0 channels from the G.703 DTE interface to the network interface.  
TS16: Data  
Data Rsvd CAS  
G.703 DTE TS16 Allocation. Specifies whether time-slot 16 (TS16) is reserved for signaling information or available for  
data.  
Data – Specifies that TS16 is available for data.  
Rsvd – Specifies that TS16 is reserved for Common-Channel Signaling information. The time slots must be directly  
connected so that the G.703 DS0 channels are connected to the corresponding network DS0 channels (e.g., D1 to N1,  
D2 to N2, etc.).  
CAS – Specifies that TS16 is reserved for Channel-Associated Signaling information. Except for time-slot 16, the other  
time slots do not need to be directly connected as they are in Common-Channel Signaling.  
NOTE: Changing this configuration option from one selection to the other (Data, Rsvd, or CAS), deallocates all DS0  
channels assigned to either the network interface or the G.703 DTE interface.  
N1 N2 N3 N4 N5 N6 N7 N8 N9 N10 N11 N12 N13 N14 N15 ... N31  
...  
G.703 DTE Channel Allocation. Assigns DS0 channels from the G.703 DTE interface to the network interface.  
Line 1 displays the 31 channels for the network interface. Line 2 displays what is allocated to the DS0 channel indicated  
in Line 1. Possible values for Line 2 are:  
Value Meaning  
This DS0 channel is not allocated. You can modify this value on this screen.  
Prtn This DS0 channel is allocated to port n, where n is a number from 1 to 4. You cannot modify this value  
on this screen.  
Dn  
This DS0 channel is allocated to the G.703 DTE interface DS0 channel n, where n is a number  
from 1 to 31. You can modify this value on this screen.  
Assign DTE channels to network channels by pressing the Function key below the network channel desired. The DTE  
channel number scrolls up one number each time you press the Function key. Only unassigned DTE channels appear  
during scrolling.  
and will not be available for allocation on this screen.  
C-8  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Configuration Options  
Table C-5  
(1 of 3)  
Data Port Channel Configuration Options  
Channel Config:  
Dsply Clear DTE Prt1 Prt2 Prt3 Prt4  
_______________________  
NOTE: The configuration options described in this table are made available by selecting Prt1, Prt2, Prt3, or Prt4  
Operation.  
Data Port Channel. Allows the assignment of a particular port to DS0 channels on either the network interface, the G.703  
DTE interface, or another port (see the Assign To configuration option below).  
NOTE: For 2-port E1 NTUs, only Ports 1 and 2 are available; for 1-port E1 NTUs, only Port 1 is available.  
Assign To: NET  
Next NET DTE Prtn Prtn Prtn Prev  
Data Port Channel Allocation Destination. Allows you to assign this port to DS0 channels on either the network interface,  
the G.703 DTE interface, or another port.  
NET – Assigns this port to DS0 channels on the network interface.  
DTE – Assigns this port to DS0 channels on the G.703 DTE interface. If the G.703 DTE interface is disabled, this  
selection is not displayed.  
Prtn – Assigns this port to another port, where n is the port number of all available ports except the port selected from the  
Channel Config screen. For example, if you select Prt1 from the Channel Config screen, Prt2, Prt3, and Prt4 appear for  
4-port E1 NTUs. Use this feature to designate a port as a backup port. You can attach an external backup device to Prtn  
and manually assign the selected port to the backup port (i.e., route data from the selected port to the backup port). When  
a port is assigned to another port, DSR is turned on. Selecting Prtn and Next takes you directly to the Port Rate  
configuration option, bypassing the Assign By configuration option. EDL (for 2-port and 4-port E1 NTUs) does not operate  
when a synchronous data port is assigned to another synchronous data port. Therefore, if EDL is enabled, it is ignored.  
NOTE: Changing this configuration option from one E1 interface to the other (NET or DTE) deallocates all DS0 channels  
allocated to the previous interface.  
Assign By: Block  
Next Block Chan Prev  
Data Port Channel Allocation Method. If NET or DTE is selected using the Assign To configuration option, this  
configuration option designates the method for assigning DS0 channels to the destination E1 interface.  
Block – Allocates DS0 channels to this port by the block method.  
Chan – Allocates DS0 channels to this port by the individual channel method.  
NOTE: If time-slot 16 is reserved for signaling, the DS0 channels associated with time-slot 16 are not available for  
assignment using either method (Block or Chan).  
NOTE: Changing this configuration option from one method to the other (Block or Chan) deallocates all DS0 channels  
assigned to either the network interface or the G.703 DTE interface.  
3360-A2-GB20-20  
December 1996  
C-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ACCULINK 336x E1 NTU  
Table C-5  
(2 of 3)  
Data Port Channel Configuration Options  
Port Rate: 384  
Next 64 128 192 256 320 384 448 512 576 640 704 768 832 896 960 1024 1088  
1152 1216 1280 1344 1408 1472 1536 1600 1664 1728 1792 1856 1920 1984 Prev  
Data Port Rate (appears when using the block channel allocation method, or when a synchronous data port is assigned  
to another synchronous data port). Designates the data rate for the port. The base rate is Nx64.  
NOTE: This configuration option does not appear if the individual channel allocation method (Chan) is selected using the  
Assign By configuration option.  
NOTE: If time-slot 16 is reserved for signaling, the highest port rate (1984) does not appear.  
NOTE: Changing this configuration option from one rate to another deallocates all DS0 channels assigned to either the  
network interface or the G.703 DTE interface.  
NOTE: When you enable EDL (for 2-port and 4-port E1 NTUs), 8 kbps of the total bandwidth allocated for this port is not  
available to the synchronous data port. For example, if you select 256 kbps and EDL is enabled, only 248 kbps  
are available.  
NOTE: When you enable EDL (for 2-port and 4-port E1 NTUs) on a synchronous data port and the clock source (either  
primary or secondary) is set to that synchronous data port, the external device must provide a clock of 8 kbps  
less than the expected data port rate. For example, if you select 64 kbps, the external clock source must supply  
a 56 kbps clock signal.  
NOTE: For the 3364 NTU there is a hardware limitation that limits the combined bandwidth used by Port 1 and Port 3 to  
a total of 2048 kbps and the combined bandwidth used by Port 2 and Port 4 to 2048 kbps. Thus, when entering  
this menu, the rate choices are limited due to this constraint. This limitation only occurs in configurations  
mapping a port to a port or when mapping ports to the G.703 DTE interface and to the network.  
Start At:  
Next Clear N1 N2 N3 N4 N5 N6 N7 N8 N9 N10 N11 ... N31 Prev  
OR  
Start At:  
Next Clear D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 ... D31 Prev  
Data Port Channel Allocation (appears for the block method only). Designates the starting DS0 channel (N1–N31 for the  
network interface and D1–D31 for the G.703 DTE interface).  
Available selections are only those DS0 channels that provide enough bandwidth (based on the configured data rate) to  
be used as a starting channel number.  
Select the desired starting channel number by pressing the Function key under that number. When you make the  
selection, the E1 NTU allocates the correct amount of DS0 channels to support the data rate currently configured for the  
port.  
Clear – Deallocates all DS0 channels for this port from either the network interface or the G.703 DTE interface.  
NOTE: This configuration option does not appear if the individual channel allocation method (Chan) is selected using the  
Assign By configuration option, or if Prtn is selected using the Assign To configuration option.  
C-10  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Configuration Options  
Table C-5  
(3 of 3)  
Data Port Channel Configuration Options  
N1 N2 N3 N4 N5 N6 N7 N8 N9 N10 N11 N12 ... N31  
Next  
OR  
...  
Prev  
Prev  
D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 ... D31  
-– ...  
Next  
Data Port Channel Allocation (appears for the individual channel method only). Designates the DS0 channel to allocate to  
this port (N1–N31 for the network interface and D1–D31 for the G.703 DTE interface).  
Line 1 displays the 31 channels for the network interface or the G.703 DTE interface. Line 2 displays what is allocated to  
the DS0 channel indicated in Line 1. Possible values for Line 2 are:  
Value Meaning  
This DS0 channel is not allocated. You can modify this value on this screen.  
Prtn  
This DS0 channel is allocated to port n, where n is a number from 1 to 4. You can modify this value  
on this screen for this port only.  
Nn  
Dn  
This DS0 channel is allocated to the network interface DS0 channel n, where n is a number from  
1 to 31. You cannot modify this value on this screen.  
This DS0 channel is allocated to the G.703 DTE interface DS0 channel n, where n is a number  
from 1 to 31. You can modify this value on this screen.  
Select the channel by pressing the Function key under that number. To deallocate a port, press the Function key under  
that port number. Pressing the Function key under channels assigned to other ports has no effect.  
NOTE: The E1 NTU automatically derives the data rate for the port from the number of DS0 channels allocated.  
NOTE: If time-slot 16 is reserved for signaling , D16 automatically connects to N16 and cannot be changed from this  
screen.  
NOTE: For the 3364 NTU there is a hardware limitation that limits the combined bandwidth used by Port 1 and Port 3 to  
a total of 2048 kbps and the combined bandwidth used by Port 2 and Port 4 to 2048 kbps. If a selection of Prtn  
causes this limit to be exceeded, the selection is ignored and the “–” will continue to be displayed for the  
channel.  
3360-A2-GB20-20  
December 1996  
C-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ACCULINK 336x E1 NTU  
General Configuration Options  
Table C-6  
General Configuration Options  
Pri Clk Src: NET  
Next NET DTE Prt1 Prt2 Prt3 Prt4 Int Ext Prev  
Primary Clock Source. Specifies the primary clock source for the E1 NTU. This selection synchronizes all internal timing  
and external interface clocks. Failure of the clock specified by this selection results in automatic fallback to the secondary  
clock source.  
NET – Configures the HDSL Network interface as the primary clock source.  
DTE – Configures the G.703 DTE interface as the primary clock source. This selection is not available if the G.703 DTE  
interface is disabled. If the G.703 DTE interface is disabled after making this selection, the primary clock source is  
changed to NET.  
Prt1, 2, 3, 4 – Configures data port 1, 2, 3, or 4 as the primary clock source. Set the same port’s Transmit Clock to  
External. If you enable EDL for the same port, the external device must provide clocking of 8 kbps less than the expected  
data port rate. For example, if you select 64 kbps, the external clock must supply a 56 kbps clock signal. This selection is  
only available on 2-port and 4-port E1 NTUs.  
Int – Configures the internal clock as the primary clock source.  
Ext – Configures an external clock (provided through the Clock In connector) as the primary clock source. This selection  
is only available on 2-port and 4-port E1 NTUs.  
NOTE: For 2-port E1 NTUs, only Ports 1 and 2 are available.  
Sec Clk Src: NET  
Next NET DTE Prt1 Prt2 Prt3 Prt4 Ext Disab Prev  
Secondary Clock Source. Specifies the secondary clock source for the E1 NTU. Failure of the clock specified by the  
Primary Clock Source selection results in automatic fallback to the secondary clock source. When this occurs, this  
selection synchronizes all internal timing and external interface clocks. Failure of the clock specified by the Secondary  
Clock Source selection results in automatic fallback to internal clock.  
NET – Configures the HDSL Network interface as the secondary clock source.  
DTE – Configures the G.703 DTE interface as the secondary clock source. This selection is not available if the G.703  
DTE interface is disabled. If the G.703 DTE interface is disabled after making this selection, the secondary clock source is  
changed to NET.  
Prt1, 2, 3, 4 – Configures data port 1, 2, 3, or 4 as the secondary clock source. Set the same port’s Transmit Clock to  
External. If you enable EDL for the same port, the external device must provide clocking of 8 kbps less than the expected  
data port rate. For example, if you select 64 kbps, the external clock must supply a 56 kbps clock signal.  
Ext – Configures an external clock (provided through the Clock In connector) as the secondary clock source.  
Disab – Disables the secondary clock source. Failure of the primary clock source results in automatic fallback to the  
internal clock.  
NOTE: This configuration option is only available on 2-port and 4-port E1 NTUs.  
NOTE: For 2-port E1 NTUs, only Ports 1 and 2 are available.  
Clock Rate: 2048  
Next 2048  
8
Prev  
External Clock Rate. Specifies the clock rate when the primary or secondary clock source is configured for external clock  
(Ext). This configuration option does not appear when the clock source is not an external clock.  
2048 – Sets the input rate of the external clock to 2,048 kHz.  
8 – Sets the input rate of the external clock to 8 kHz.  
NOTE: This configuration option is only available on 2-port and 4-port E1 NTUs.  
C-12  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Configuration Options  
User Interface  
Configuration Options  
Table C-7  
(1 of 3)  
User Interface Configuration Options  
Self-Test: Enab  
Next Enab Disab Prev  
Initial Self-Test. Specifies whether the E1 NTU performs a device self-test at power-up and after a device reset.  
Enab – Enables a self-test.  
Disab – Disables the self-test.  
Com Use: ASCII  
Next SNMP ASCII Daisy Prev  
Communication Port Use. Specifies how the communication port is used. The communication port can be configured for  
only one use (each use is mutually exclusive): it can be configured as the management link to an external SNMP  
manager, it can be configured as a proprietary ASCII port, or it can be configured as an SNMP management link daisy  
chained to another 33xx Series device.  
SNMP – Specifies that the communication port is used as the management link to an external SNMP manager.  
ASCII – Specifies that the communication port is used as a proprietary ASCII port supporting Front Panel Emulation  
software and ASCII alarm messages.  
Daisy – Specifies that the communication port is used as an SNMP management port that is daisy chained to the  
auxiliary port of an another 33xx Series device.  
NOTE: SNMP and ASCII selections can be made using the ifAdminStatus MIB object (up = SNMP, testing = ASCII).  
NOTE: The Daisy selection requires the use of a customer-supplied, 8-pin-to-8-pin, straight-through cable. Whenever  
the cable is connected or disconnected, change the Daisy selection to another selection, and then back to Daisy,  
to ensure that the correct parameters have been negotiated for the link layer.  
Com Type: Async  
Next Async Sync Prev  
Communication Port Type. Specifies whether the communication port uses synchronous or asynchronous operation when  
it is configured as the SNMP management link.  
Async – Configures the communication port for asynchronous operation.  
Sync – Configures the communication port for synchronous operation.  
NOTE: This configuration option is not available if the Com Use configuration option is set to ASCII or Daisy. In these  
cases, the communication port is always asynchronous.  
Com Clk: Int  
Next Int Ext Prev  
Communication Port Synchronous Clock. Specifies whether the communication port uses internal or external clocking  
when it is configured for synchronous operation.  
Int – Configures the communication port for internal clocking.  
Ext – Configures the communication port for external clocking.  
NOTE: This configuration option is not available if the Com Type configuration option is set to Async.  
3360-A2-GB20-20  
December 1996  
C-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
ACCULINK 336x E1 NTU  
Table C-7  
(2 of 3)  
User Interface Configuration Options  
Com Rate: 9.6  
Next 1.2 2.4 4.8 9.6 14.4 19.2 38.4 Prev  
Communication Port Rate. Configures the bit rate for the communication port.  
1.2 – Sets the bit rate to 1200 bps.  
2.4 – Sets the bit rate to 2400 bps.  
4.8 – Sets the bit rate to 4800 bps.  
9.6 – Sets the bit rate to 9600 bps.  
14.4 – Sets the bit rate to 14,400 bps.  
19.2 – Sets the bit rate to 19,200 bps.  
38.4 – Sets the bit rate to 38,400 bps.  
NOTE: This configuration option is not available if the communication port is configured for synchronous operation and  
the clock source is external.  
Char Length: 8  
Next  
7
8
Prev  
Communication Port Character Length. Configures the character length (7 or 8 bits) for the communication port.  
NOTE: This configuration option must be set to 8 if the communication port is used for Front Panel Emulation or SNMP  
management.  
NOTE: This configuration option is not available if the communication port is configured for synchronous operation.  
CParity: None  
Next None Even Odd Prev  
Communication Port Parity. Configures the parity (none, even, or odd) for the communication port.  
NOTE: This configuration option is not available if the communication port is configured for synchronous operation.  
CStop Bits: 1  
Next  
1
1.5  
2
Prev  
Communication Port Stop Bits. Configures the number of stop bits (1, 1.5, or 2) for the communication port.  
NOTE: This configuration option is not available if the communication port is configured for synchronous operation.  
C-14  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Configuration Options  
Table C-7  
(3 of 3)  
User Interface Configuration Options  
Ignore DTR: No  
Next Yes No Prev  
Communication Port Ignore DTR State. Specifies whether the E1 NTU ignores the state of the Data Terminal Ready  
(DTR) input to the communication port.  
Yes – DTR is ignored.  
No – DTR is not ignored.  
NOTE: This configuration option is not available if the communication port is configured for synchronous operation.  
Aux Use: None  
Next None SNMP Daisy Prev  
Auxiliary Port Use. Specifies how the auxiliary port is used. The auxiliary port only supports Point-to-Point Protocol (PPP)  
with the following parameters: type is asynchronous, character length is 8, parity is none, and stop bit is 1.  
None – Specifies that the auxiliary port is not to be used.  
SNMP – Specifies that the auxiliary port is to be used as the management link to an external SNMP manager via an  
external LAN Adapter.  
Daisy – Specifies that the auxiliary port is to be used as an SNMP management link that is daisy chained to the  
communication port of another 33xx Series device.  
NOTE: The Daisy or SNMP selection requires the use of a customer-supplied, 8-pin-to-8-pin, straight-through cable.  
Whenever the cable is connected or disconnected, change the selection to None, and then back to Daisy or  
SNMP, to ensure that the correct parameters have been negotiated for the link layer.  
Aux Rate: 19.2  
Next 9.6 14.4 19.2 38.4 Prev  
Auxiliary Port Rate. Configures the bit rate for the auxiliary port.  
9.6 – Configures the auxiliary port rate as 9600 bps.  
14.4 – Configures the auxiliary port rate as 14,400 bps.  
19.2 – Configures the auxiliary port rate as 19,200 bps.  
38.4 – Configures the auxiliary port rate as 38,400 bps.  
3360-A2-GB20-20  
December 1996  
C-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ACCULINK 336x E1 NTU  
Alarm Configuration Options  
Table C-8  
Alarm Configuration Options  
Alrm Msg: Disab  
Next Enab Disab Prev  
Alarm Messages. Controls the generation of alarm messages, which are routed to an ASCII terminal or printer attached to  
Enab – Enables alarm messages routed to the communication port.  
Disab – Prevents alarm messages for any alarm conditions.  
NOTE: Alarm messages are only sent to the communication port if the Com Use configuration option is set to ASCII,  
otherwise the alarm messages are discarded.  
SNMP Trap: Disab  
Next Enab Disab Prev  
SNMP Trap Enable. Specifies whether SNMP trap messages are sent over the SNMP management link. For more  
Enab – Enables sending SNMP trap messages from this unit over any SNMP management link.  
Disab – Disables sending SNMP trap messages from this unit over any SNMP management link.  
C-16  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Configuration Options  
SNMP Configuration Options  
The SNMP configuration options are divided into two  
tables as follows:  
Table C-9  
(1 of 4)  
General SNMP Configuration Options  
System Name:  
Next Edit Clear Prev  
System Name. Specifies the SNMP system name for this unit. This is the name of this SNMP-managed node.  
Edit – Allows you to edit or display the system name.  
Clear – Allows you to clear the system name.  
System Location:  
Next Edit Clear Prev  
System Location. Specifies the SNMP system location for this unit. This is the physical location of this SNMP-managed  
node.  
Edit – Allows you to edit or display the system location.  
Clear – Allows you to clear the system location.  
System Contact:  
Next Edit Clear Prev  
System Contact. Specifies the SNMP system contact person for this unit, and how to contact this person.  
Edit – Allows you to edit or display the system contact.  
Clear – Allows you to clear the system contact.  
CommunityName1:public  
Next Edit Clear Prev  
Community Name 1. Specifies the first of two community names that are allowed to access this unit’s Management  
Information Base (MIB). External SNMP managers must supply this name to access an object in the MIB.  
Edit – Allows you to edit or display the first community name. The factory default sets this string to public.  
Clear – Allows you to clear the first community name.  
Access 1: Read  
Next Read R/W Prev  
Access 1. Specifies the type of access allowed for community name 1. This is the type of access allowed for external  
SNMP managers accessing objects in the MIB using community name 1.  
Read – Allows read-only access (SNMP Get) to the accessible objects in the MIB for this device when community  
name 1 is used. This includes all objects specified as either read-only or read/write in the MIB RFCs.  
R/W – Allows read and write access (SNMP Get and Set) to the objects in the MIB for this device when community  
name 1 is used. Write access is allowed for all objects specified as read/write in the MIB RFCs. Read access is allowed  
for all objects specified as either read-only or read/write.  
3360-A2-GB20-20  
December 1996  
C-17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
ACCULINK 336x E1 NTU  
Table C-9  
(2 of 4)  
General SNMP Configuration Options  
CommunityName2:  
Next Edit Clear Prev  
Community Name 2. Specifies the second of two community names that are allowed to access this unit’s Management  
Information Base (MIB). External SNMP managers must supply this name to access an object in the MIB.  
Edit – Allows you to edit or display the second community name.  
Clear – Allows you to clear the second community name.  
Access 2: Read  
Next Read R/W Prev  
Access 2. Specifies the type of access allowed for community name 2. This is the type of access allowed for external  
SNMP managers accessing objects in the MIB using community name 2.  
Read – Allows read-only access (SNMP Get) to the accessible objects in the MIB for this device when community  
name 2 is used. This includes all objects specified as either read-only or read/write in the MIB RFCs.  
R/W – Allows read and write access (SNMP Get and Set) to the objects in the MIB for this device when community  
name 2 is used. Write access is allowed for all objects specified as read/write in the MIB RFCs. Read access is allowed  
for all objects specified as either read-only or read/write.  
IP Adr:  
Next Edit Clear Prev  
IP Address for the E1 NTU. Specifies the IP address needed to access the E1 NTU. Since this IP Address is not bound to  
a particular port, it can be used for remote access via the FDL or EDL (for 2-port and 4-port E1 NTUs) management link.  
Edit – Allows you to edit and/or display the IP address for the E1 NTU.  
Clear – Allows you to clear the IP address for the E1 NTU. The IP address is set to 000.000.000.000.  
NetMask:  
Next Edit Clear Prev  
Subnet Mask for the E1 NTU. Specifies the subnet mask needed to access the E1 NTU. Since this subnet mask is not  
bound to a particular port, it can be used for remote access via the FDL or EDL (for 2-port and 4-port E1 NTUs)  
management link.  
Edit – Allows you to edit and/or display the subnet mask for the E1 NTU.  
Clear – Allows you to clear the subnet mask for the E1 NTU. The subnet mask is set to 000.000.000.000. If the subnet  
mask is 000.000.000.000, the IP protocol creates a default subnet mask based on the class of the IP address (Class A:  
255.000.000.000, Class B: 255.255.000.000, or Class C: 255.255.255.000).  
C-18  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Configuration Options  
Table C-9  
(3 of 4)  
General SNMP Configuration Options  
Com IP Adr:  
Next Edit Clear Prev  
Com Port IP Address. Specifies the IP address for the communication port when it is configured as the SNMP  
management link. The IP address is only in effect when the Com Use configuration option is set to SNMP or Daisy.  
Edit – Allows you to edit or display the IP address for the communication port.  
Clear – Allows you to clear the IP address for the communication port. The IP address is set to 000.000.000.000.  
Com NetMask:  
Next Edit Clear Prev  
Subnet Mask for the Communication Port. Specifies the subnet mask needed to access the unit when the communication  
port is configured as the SNMP management link. The subnet mask is only in effect when the Com Use configuration  
option is set to SNMP or Daisy.  
Edit – Allows you to edit and/or display the subnet mask for the communication port.  
Clear – Allows you to clear the subnet mask for the communication port. The subnet mask is set to 000.000.000.000. If  
the subnet mask is 000.000.000.000, the IP protocol creates a default subnet mask based on the class of the IP address  
(Class A: 255.000.000.000, Class B: 255.255.000.000, or Class C: 255.255.255.000).  
Com Link: PPP  
Next PPP SLIP Prev  
Com Port Link Layer Protocol. Specifies the link layer protocol for the communication port when it is configured as the  
SNMP management link. This protocol is only in effect when the Com Use configuration option is set to SNMP.  
PPP – Specifies PPP as the link layer protocol for the SNMP management link on the communication port.  
SLIP – Specifies SLIP as the link layer protocol for the SNMP management link on the communication port. The  
communication port must be configured for asynchronous operation to support SLIP. This selection does not appear if the  
Com Use configuration option is set to Daisy.  
3360-A2-GB20-20  
December 1996  
C-19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ACCULINK 336x E1 NTU  
Table C-9  
(4 of 4)  
General SNMP Configuration Options  
Aux IP Adr:  
Next Edit Clear Prev  
IP Address for the Auxiliary Port. Specifies the IP address needed to access the unit when the auxiliary port is configured  
as the SNMP management link. The IP address is only in effect when the Aux Use configuration option is set to SNMP or  
Daisy. The auxiliary port only supports the PPP link protocol.  
Edit – Allows you to edit and/or display the IP address for the auxiliary port.  
Clear – Allows you to clear the IP address for the auxiliary port. The IP address is set to 000.000.000.000.  
Aux NetMask:  
Next Edit Clear Prev  
Subnet Mask for the Auxiliary Port. Specifies the subnet mask needed to access the unit when the auxiliary port is  
configured as the SNMP management link. The subnet mask is only in effect when the Aux Use configuration option is  
set to SNMP or Daisy.  
Edit – Allows you to edit and/or display the subnet mask for the auxiliary port.  
Clear – Allows you to clear the subnet mask for the auxiliary port. The subnet mask is set to 000.000.000.000. If the  
subnet mask is 000.000.000.000, the IP protocol creates a default subnet mask based on the class of the IP address  
(Class A: 255.000.000.000, Class B: 255.255.000.000, or Class C: 255.255.255.000).  
Def Netwk: None  
Next None Com Aux FDL EDL1 EDL2 EDL3 EDL4 Prev  
Default Network Destination. Specifies the default network destination. This configuration option specifies where the  
default network is connected. For example, if the default network is connected to the communication port, you select  
Com. If the default network is connected to the far-end 33xx Series device over the FDL, you select FDL. The routing  
protocol uses the default network destination to route data that does not have a specific route.  
None – No default network destination. Data that cannot be routed is discarded.  
Com – The default network destination is the communication port. This selection only appears if the Com Use  
configuration option is set to SNMP.  
Aux – The default network destination is the auxiliary port. This selection only appears if the Aux Use configuration option  
is set to SNMP.  
FDL – The default network destination is FDL. This selection only appears if the FDL management link is enabled for  
SNMP.  
EDLn – For 2-port and 4-port E1 NTUs, the default network destination is the EDLn port (where n is 14). This selection  
only appears in 2-port and 4-port E1 NTUs if the synchronous data port’s EDL management link is enabled for SNMP.  
NOTE: If the chosen default network link is disabled or down, data is discarded. Return to this menu and choose another  
default network.  
C-20  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Configuration Options  
Table C-10  
(1 of 2)  
SNMP Trap Configuration Options  
Num Trap Mgrs: 1  
Next  
1
2
3
4
5
6
Prev  
Number of Trap Managers. Specifies the number of SNMP trap managers that are to receive traps for this unit.  
NOTE: You must configure an IP address for each trap manager that is to receive trap messages.  
Trapn IP Adr:  
Next Edit Clear Prev  
Trap n IP Address. Specifies the IP address for each trap manager. This configuration option is repeated for all trap  
managers supported by the unit.  
Edit – Allows you to edit or display the IP address for Trap Manager n.  
Clear – Allows you to clear the IP address for Trap Manager n. The IP address is set to 000.000.000.000.  
Trapn Dst: None  
Next None Com Aux FDL EDL1 EDL2 EDL3 EDL4 Prev  
Trap Manager n Destination. Specifies the network destination for Trap Manager n. This configuration option is displayed  
for the number of trap managers (n) specified by the Number of Trap Managers configuration option.  
None – No Trap Manage n network destination. Traps are discarded.  
Com – The Trap Manager n network destination is the communication port. This selection only appears if the Com Use  
configuration option is set to SNMP or Daisy.  
Aux – The Trap Manager n network destination is the auxiliary port. This selection only appears if the Aux Use  
configuration option is set to SNMP or Daisy.  
FDL – The Trap Manager n network destination is the FDL management link. This selection only appears if the FDL  
management link is enabled for SNMP.  
EDLn – The Trap Manager n network destination is the EDLn port (where n is 14). This selection only appears if the  
synchronous data port’s EDL management link is enabled for SNMP.  
NOTE: If the chosen destination link is disabled or down, the traps are discarded. Return to this menu and choose  
another destination.  
Gen Trap: Both  
Next Disab Warm Auth Both Prev  
Chapter 4, Maintenance.  
Disab – Disables the sending of trap messages for warmStart and authenticationFailure events.  
Warm – Sends trap messages for warmStart events to the currently configured trap manager(s).  
Auth – Sends trap messages for authenticationFailure events to the currently configured trap manager(s).  
Both – Sends trap messages for warmStart and authenticationFailure events to the currently configured trap manager(s).  
NOTE: This configuration option is not available if the SNMP Trap configuration option (in the Alarm Configuration  
3360-A2-GB20-20  
December 1996  
C-21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ACCULINK 336x E1 NTU  
Table C-10  
(2 of 2)  
SNMP Trap Configuration Options  
Entp Trap: Enab  
Next Enab Disab Prev  
Enterprise Specific Traps. Specifies whether enterpriseSpecific traps are enabled. For more information, refer to the  
Enab – Sends trap messages for enterpriseSpecific events to the currently configured trap manager(s).  
Disab – Disables the sending of trap messages for enterpriseSpecific events.  
NOTE: This configuration option is not available if the SNMP Trap configuration option (in the Alarm Configuration  
Link Trap: Both  
Next Disab Up Down Both Prev  
Link Trap Type. Specifies the link trap type to enable. Interfaces monitored for linkUp and linkDown traps are specified  
Disab – Disables the sending of trap messages for linkDown or linkUp events.  
Up – Sends trap messages for linkUp events to the currently configured trap manager(s).  
Down – Sends trap messages for linkDown events to the currently configured trap manager(s).  
Both – Sends trap messages for linkUp and linkDown events to the currently configured trap manager(s).  
NOTE: This configuration option is not available if the SNMP Trap configuration option (in the Alarm Configuration  
Trap I/F: All  
Next NET DTE E1s Ports All Prev  
Link Trap Interfaces. Specifies which interfaces generate linkUp and linkDown trap messages. These traps are supported  
on the E1 interfaces (network and G.703 DTE) and the synchronous data ports.  
NET – Sends trap messages for linkUp, linkDown, enterpriseTestStart, or enterpriseTestClear events occurring on the  
network interface.  
DTE – Sends trap messages for linkUp, linkDown, enterpriseTestStart, or enterpriseTestClear events occurring on the  
G.703 DTE interface. This selection is not displayed if the G.703 DTE interface is disabled.  
E1s – Sends trap messages for linkUp, linkDown, enterpriseTestStart, or enterpriseTestClear events occurring on either  
the network or G.703 DTE interface.  
Ports – Sends trap messages for linkUp, linkDown, enterpriseTestStart, or enterpriseTestClear events occurring on the  
synchronous data ports.  
All – Sends trap messages for linkUp, linkDown, enterpriseTestStart, or enterpriseTestClear events occurring on the  
network interface, G.703 DTE interface, or the synchronous data ports.  
NOTE: This configuration option is not available if the Link Trap configuration option is not configured to generate trap  
messages for linkUp or linkDown events.  
C-22  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Configuration Options  
Configuration Worksheets  
This section contains one set of blank worksheets to be  
used when configuring your E1 NTU in the network. It is  
recommended that you copy these blank worksheets  
before using them.  
DTE Options  
DTE Port  
Value  
User Options  
Self-Test  
Value  
Enab, Disab  
Enab, Disab  
CRC4, noCRC  
AMI, HDB3  
Com Use  
Com Type  
Com Clk  
SNMP, ASCII, Daisy  
Async, Sync  
Int, Ext  
DTE Frame  
DTE Coding  
Extrn DLB  
Enab, Disab  
Enab, Disab  
Com Rate  
Char Length  
CParity  
1.2, 2.4, 4.8, 9.6, 14.4, 19.2, 38.4  
7, 8  
Send Ones  
None, Even, Odd  
1, 1.5, 2  
CStop Bits  
Ignore DTR  
Aux Use  
Yes, No  
Net Options  
HDSL Mode  
NET Frame  
Mgmt Link  
HDSL  
Value  
None, SNMP, Daisy  
9.6, 14.4, 19.2, 38.4  
NTU, LTU  
Aux Rate  
CRC4, noCRC  
Disab, SNMP  
Disab, Maint  
Edit, Clear  
Alarm  
Options  
Circuit Ident  
Value  
Alrm Msg  
Enab, Disab  
Enab, Disab  
SNMP Trap  
General  
Options  
Value  
Pri Clk Src  
Sec Clk Src  
Clock Rate  
NET, DTE, Prt1, Prt2, Prt3, Prt4, Int,  
Ext  
NET, DTE, Prt1, Prt2, Prt3, Prt4, Ext,  
Disab  
2048, 8  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C-23  
   
ACCULINK 336x E1 NTU  
Prt1 Options  
Value  
Prt3 Options  
Port Type  
NetDCLB  
Port LB  
Value  
E530, V.35, RS449, X.21  
Enab, Disab  
Port Type  
NetDCLB  
Port LB  
E530, V.35, RS449, X.21  
Enab, Disab  
Disab, DTLB, DCLB, Both  
Disab, DTR, RTS, Both  
None, Halt  
Disab, DTLB, DCLB, Both  
Disab, DTR, RTS, Both  
None, Halt  
All Ones  
Rcv RAI  
Tx Clock  
InvertTxC  
InvrtData  
EDL  
All Ones  
Rcv Yellow  
Tx Clock  
InvertTxC  
InvrtData  
EDL  
Int, Ext  
Int, Ext  
Enab, Disab  
Enab, Disab  
Enab, Disab  
Enab, Disab  
Enab, Disab  
Enab, Disab  
Err Rate  
10E–4, 10E–5, 10E–6, 10E–7, 10E–8,  
10E–9  
Err Rate  
10E–4, 10E–5, 10E–6, 10E–7, 10E–8,  
10E–9  
Near-end  
Far-end  
Disab, Maint, Send, Both  
Disab, Maint  
Near-end  
Far-end  
Disab, Maint, Send, Both  
Disab, Maint  
Mgmt Link  
Disab, SNMP  
Mgmt Link  
Disab, SNMP  
Prt2 Options  
Port Type  
NetDCLB  
Port LB  
Value  
E530, V.35, RS449, X.21  
Enab, Disab  
Prt4 Options  
Port Type  
NetDCLB  
Port LB  
Value  
E530, V.35, RS449, X.21  
Enab, Disab  
Disab, DTLB, DCLB, Both  
Disab, DTR, RTS, Both  
None, Halt  
Disab, DTLB, DCLB, Both  
Disab, DTR, RTS, Both  
None, Halt  
All Ones  
Rcv Yellow  
Tx Clock  
InvertTxC  
InvrtData  
EDL  
All Ones  
Rcv Yellow  
Tx Clock  
InvertTxC  
InvrtData  
EDL  
Int, Ext  
Int, Ext  
Enab, Disab  
Enab, Disab  
Enab, Disab  
Enab, Disab  
Enab, Disab  
Enab, Disab  
Err Rate  
10E–4, 10E–5, 10E–6, 10E–7, 10E–8,  
10E–9  
Err Rate  
10E–4, 10E–5, 10E–6, 10E–7, 10E–8,  
10E–9  
Near-end  
Far-end  
Disab, Maint, Send, Both  
Disab, Maint  
Near-end  
Far-end  
Disab, Maint, Send, Both  
Disab, Maint  
Mgmt Link  
Disab, SNMP  
Mgmt Link  
Disab, SNMP  
C-24  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
 
Configuration Options  
Network Interface  
Network Channel Allocation  
G.703 DTE Interface  
G.703 Channel Allocation  
N1  
N2  
N3  
N4  
N5  
N6  
N7  
N8  
N9  
D1  
D2  
D3  
D4  
D5  
D6  
D7  
D8  
D9  
N10  
N11  
D10  
D11  
D12  
D13  
D14  
D15  
D16  
D17  
D18  
D19  
D20  
D21  
D22  
D23  
D24  
D25  
D26  
D27  
D28  
D29  
D30  
D31  
N12  
N13  
N14  
N15  
N16  
N17  
N18  
N19  
N20  
N21  
N22  
N23  
N24  
N25  
N26  
N27  
N28  
N29  
N30  
N31  
Allocations  
Allocations  
D1 – D31 indicates allocation to DTE  
(G.703) channels.  
N1 – N31 indicates allocation to network  
channels.  
Prt1 – Prt4 indicates allocation to  
synchronous data ports.  
Prt1 – Prt4 indicates allocation to  
synchronous data ports.  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C-25  
 
ACCULINK 336x E1 NTU  
Port Chan  
Conf  
Options  
Value  
Assign To  
Assign By  
NET, DTE, Prt2, Prt3, Prt4  
Block, Chan  
Port Rate  
Nx64: 64, 128, 192, 256, 320, 384, 448, 512, 576,  
640, 704, 768, 832, 896, 960, 1024, 1088, 1152,  
1216, 1280, 1344, 1408, 1472, 1536, 1600, 1664,  
1728, 1792, 1856, 1920, 1984  
NOTE: If time-slot 16 is reserved for signaling, the  
If Assign By Block  
If Assign By Chan  
Port 1  
highest port rate (1984) does not appear.  
Start At  
Time Slot (Nn or Dn): 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,  
12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25,  
26, 27, 28, 29, 30, 31 (Select One)  
Time Slot (Nn or Dn): 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,  
12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25,  
26, 27, 28, 29, 30, 31 (Select Multiple)  
Assign To  
Assign By  
NET, DTE, Prt1, Prt3, Prt4  
Block, Chan  
Port Rate  
Nx64: 64, 128, 192, 256, 320, 384, 448, 512, 576,  
640, 704, 768, 832, 896, 960, 1024, 1088, 1152,  
1216, 1280, 1344, 1408, 1472, 1536, 1600, 1664,  
1728, 1792, 1856, 1920, 1984  
NOTE: If time-slot 16 is reserved for signaling, the  
If Assign By Block  
If Assign By Chan  
Port 2  
highest port rate (1984) does not appear.  
Start At  
Time Slot (Nn or Dn): 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,  
12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25,  
26, 27, 28, 29, 30, 31 (Select One)  
Time Slot (Nn or Dn): 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,  
12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25,  
26, 27, 28, 29, 30, 31 (Select Multiple)  
C-26  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
 
Configuration Options  
Port Chan  
Conf  
Options  
Value  
Assign To  
Assign By  
NET, DTE, Prt1, Prt2, Prt4  
Block, Chan  
Port Rate  
Nx64: 64, 128, 192, 256, 320, 384, 448, 512, 576,  
640, 704, 768, 832, 896, 960, 1024, 1088, 1152,  
1216, 1280, 1344, 1408, 1472, 1536, 1600, 1664,  
1728, 1792, 1856, 1920, 1984  
NOTE: If time-slot 16 is reserved for signaling, the  
If Assign By Block  
If Assign By Chan  
Port 3  
highest port rate (1984) does not appear.  
Start At  
Time Slot (Nn or Dn): 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,  
12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25,  
26, 27, 28, 29, 30, 31 (Select One)  
Time Slot (Nn or Dn): 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,  
12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25,  
26, 27, 28, 29, 30, 31 (Select Multiple)  
Assign To  
Assign By  
NET, DTE, Prt1, Prt2, Prt3  
Block, Chan  
Port Rate  
Nx64: 64, 128, 192, 256, 320, 384, 448, 512, 576,  
640, 704, 768, 832, 896, 960, 1024, 1088, 1152,  
1216, 1280, 1344, 1408, 1472, 1536, 1600, 1664,  
1728, 1792, 1856, 1920, 1984  
NOTE: If time-slot 16 is reserved for signaling, the  
If Assign By Block  
If Assign By Chan  
Port 4  
highest port rate (1984) does not appear.  
Start At  
Time Slot (Nn or Dn): 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,  
12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25,  
26, 27, 28, 29, 30, 31 (Select One)  
Time Slot (Nn or Dn): 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,  
12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25,  
26, 27, 28, 29, 30, 31 (Select Multiple)  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C-27  
 
ACCULINK 336x E1 NTU  
General SNMP  
Options  
SNMP Trap  
Options  
Value  
Value  
System Name  
System Location  
System Contact  
CommunityName1  
Access 1  
Edit, Clear  
Edit, Clear  
Edit, Clear  
Edit, Clear  
Read, R/W  
Edit, Clear  
Read, R/W  
Edit, Clear  
Edit, Clear  
Edit, Clear  
Edit, Clear  
PPP, SLIP  
Edit, Clear  
Edit, Clear  
Num Trap Mgrs  
Trapn IP Adr  
Trapn Dst  
1, 2, 3, 4, 5, 6  
Edit, Clear  
None, Com, Aux, FDL, EDL1,  
EDL2, EDL3, EDL4  
Gen Trap  
Entp Trap  
Link Trap  
Trap I/F  
Disab, Warm, Auth, Both  
Enab, Disab  
CommunityName2  
Access 2  
Disab, Up, Down, Both  
NET, DTE, E1s, Ports, All  
IP Adr  
NetMask  
Com IP Adr  
Com NetMask  
Com Link  
Aux IP Adr  
Aux NetMask  
None, Com, Aux, FDL, EDL1,  
EDL2, EDL3, EDL4  
Def Netwk  
C-28  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
 
Pin Assignments  
D
AUX Port Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-3  
Overview  
HDSL Network Interface  
The E1 NTU is shipped with a power module. Various  
other interconnecting cables are available from the  
company. For cable feature numbers, refer to Appendix H,  
assignments for the E1 NTU, Paradyne cables, and  
customer-supplied cables.  
The HDSL Network interface is an 8-position, unkeyed  
Table D-1  
HDSL Network Connector  
Signal  
Pin Number  
Loop 2 Ring  
Loop 2 Tip  
Unused  
1
2
3
4
5
6
7
8
Loop 1 Ring  
Loop 1 Tip  
Unused  
Unused  
Unused  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-1  
       
ACCULINK 336x E1 NTU  
G.703 DTE Interface  
Table D-2  
G.703 DTE Connector (120 Ohm)  
The G.703 DTE interface is either two BNC  
connectors (Transmit and Receive) for a 75 ohm  
unbalanced interface, or a DB15-type socket connector  
information about using Relay Contact Sense for external  
DTE loopback, refer to the Extrn DLB configuration  
of Appendix C.  
Signal  
Pin Number  
Receiver Tip from DTE  
Receiver Ring from DTE  
Transmitter Tip to DTE  
Transmitter Ring to DTE  
Relay Contact Sense Return  
Relay Contact Sense  
Shield Ground  
1
9
3
11  
12  
14  
2, 4  
supplied by a DTE vendor. It is made of shielded  
twisted-pair wires (22 AWG). The cable connector is a  
DB15 plug. Be sure to connect the shield ground only at  
the E1 NTU end to prevent ground loops.  
Figure D-1. G.703 DTE Cable  
D-2  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
       
Pin Assignments  
AUX Port Interface  
NOTE  
The Auxiliary (AUX) port connects to the SNMP LAN  
Adapter for SNMP applications, or to another E1 NTU’s  
COM port for daisy chain connectivity. (The SNMP LAN  
Adapter includes the cable that is needed to attach it to  
the E1 NTU.) The AUX port connector is an 8-pin  
For daisy-chaining an AUX port  
to a COM port, a customer  
supplied, 8-pin-to-8-pin, straight-  
through cable is required and  
the appropriate configuration  
options (Com Use and Aux Use)  
must be set to Daisy. Whenever  
the cable is connected or  
disconnected, you should  
change the Daisy selection to  
ensure that the correct  
parameters have been  
negotiated for the link layer.  
Table D-3  
AUX Port Connector  
Direction  
From NTU  
To NTU  
Signal  
DTE Transmit Clock  
DTE Receive Data  
Signal Ground  
Pin Number  
1
2
3
4
8
DTE Transmit Data  
DTE Receive Clock  
From NTU  
From NTU  
3360-A2-GB20-20  
December 1996  
D-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
ACCULINK 336x E1 NTU  
COM Port Interface  
NOTE  
The COM port connects to a PC for front panel  
emulation, to an ASCII terminal or printer for alarms, to a  
network device (e.g., a router) for SNMP applications, to  
the SNMP LAN Adapter for SNMP applications, or to  
another E1 NTU’s AUX port for daisy chain connectivity.  
(The SNMP LAN Adapter includes the cable that is  
needed to attach it to the E1 NTU.) The COM port  
connector is an 8-position keyed modular connector  
a DTE interface.  
For daisy-chaining an AUX port  
to a COM port, a customer  
supplied, 8-pin-to-8-pin, straight-  
through cable is required and  
the appropriate configuration  
options (Com Use and Aux Use)  
must be set to Daisy. Whenever  
the cable is connected or  
disconnected, you should  
change the Daisy selection to  
ensure that the correct  
the COM port-to-terminal/printer cable is shown in  
parameters have been  
negotiated for the link layer.  
Table D-4  
COM Port Connector  
Direction  
From NTU  
From NTU  
Signal  
DCE Transmit Clock  
DCE Receive Data  
Signal Ground  
Pin Number  
1
2
3
4
5
6
7
8
DCE Transmit Data  
DCE Data Terminal Ready  
DCE Carrier Detect  
DCE Request-to-Send  
DCE Receive Clock  
To NTU  
To NTU  
From NTU  
To NTU  
From NTU  
D-4  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Pin Assignments  
Figure D-2. COM Port-to-PC Cable  
Figure D-3. COM Port-to-Terminal/Printer Cable  
3360-A2-GB20-20  
December 1996  
D-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
ACCULINK 336x E1 NTU  
EIA 530A Port Interface  
Connector  
The EIA 530A Port interface connector information is  
Table D-5  
EIA 530A Port Interface Connector  
Circuit  
Mnemonic  
CCITT  
Number  
Signal  
Direction  
Pin  
Shield  
AB  
AC  
BA  
1
7
Signal Common  
Signal Common  
Transmitted Data  
102A  
102B  
103  
23  
To NTU  
2 (A)  
14 (B)  
Received Data  
Request-to-Send  
Clear-to-Send  
BB  
CA  
CB  
CF  
104  
105  
106  
109  
From NTU  
To NTU  
3 (A)  
16 (B)  
4 (A)  
19 (B)  
From NTU  
From NTU  
5 (A)  
13 (B)  
Received Line Signal Detector  
8 (A)  
10 (B)  
DCE Ready  
CC  
CD  
DA  
107  
108/1, /2  
113  
From NTU  
To NTU  
6
DTE Ready  
20  
Transmit Signal Element Timing (DTE Source)  
To NTU  
11 (B)  
24 (A)  
Transmit Signal Element Timing (DCE Source)  
Receiver Signal Element Timing (DCE Source)  
DB  
DD  
114  
115  
From NTU  
From NTU  
12 (B)  
15 (A)  
17 (A)  
9 (B)  
Local Loopback  
Remote Loopback  
Test Mode  
LL  
RL  
TM  
141  
140  
142  
To NTU  
18  
21  
25  
To NTU  
From NTU  
D-6  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Pin Assignments  
EIA 530A-to-RS449  
Cable Interface  
530  
SIGNAL  
DB37 449  
SOCKET SIGNAL  
DB25  
PLUG  
SHIELD  
TD-A  
1
1
SHIELD  
TD-A  
2
4
TD-B  
14  
3
22  
6
TD-B  
RD-A  
RD-A  
RD-B  
16  
15  
12  
17  
9
24  
5
RD-B  
TXC-A  
TXC-B  
RXC-A  
RXC-B  
RTS-A  
RTS-B  
CTS-A  
CTS-B  
DTR  
TXC-A  
TXC-B  
RXC-A  
RXC-B  
RTS-A  
RTS-B  
CTS-A  
CTS-B  
DTR-A  
RR-A  
23  
8
26  
7
4
19  
5
25  
9
13  
20  
8
27  
12  
13  
31  
11  
19  
14  
10  
20  
17  
35  
18  
RLSD-A  
RLSD-B  
DSR  
10  
6
RR-B  
DM-A  
SIG. COMMON  
RL  
7
SIG. COMMON  
RL  
21  
18  
23  
24  
11  
25  
22  
LL  
LL  
RCV. COMMON  
TT-A  
RCV. COMMON  
TT-A  
TT-B  
TT-B  
TM  
TM  
SIG. COMMON  
29  
30  
DM-B  
DTR-B  
495-14323-01  
Figure D-4. EIA 530A-to-RS449 Cable  
3360-A2-GB20-20  
December 1996  
D-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
ACCULINK 336x E1 NTU  
Table D-6  
RS449 Cable Interface  
Circuit  
Mnemonic  
CCITT  
Number  
Signal  
Direction  
Pin  
Shield  
102A  
102B  
1
Signal Ground  
Receive Ground  
Send Common  
Send Data  
SG  
RC  
SC  
SD  
19  
20  
37  
103  
To NTU  
4 (A)  
22 (B)  
Receive Data  
Request-to-Send  
Clear-to-Send  
Receiver Ready  
Data Mode  
RD  
RS  
CS  
RR  
DM  
TR  
TT  
104  
105  
From NTU  
To NTU  
6 (A)  
24 (B)  
7 (A)  
25 (B)  
106  
From NTU  
From NTU  
From NTU  
To NTU  
9 (A)  
27 (B)  
109  
13 (A)  
31 (B)  
107  
11 (A)  
29 (B)  
Terminal Ready  
Terminal Timing  
Send Timing  
108/1, /2  
113  
12 (A)  
30 (B)  
To NTU  
17 (A)  
35 (B)  
ST  
RT  
114  
From NTU  
From NTU  
5 (A)  
23 (B)  
Receive Timing  
115  
8 (A)  
26 (B)  
Local Loopback  
Remote Loopback  
Test Mode  
LL  
RL  
TM  
141  
140  
142  
To NTU  
10  
14  
18  
To NTU  
From NTU  
D-8  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Pin Assignments  
EIA 530A-to-V.35  
Cable Interface  
530 DB25  
SIGNAL PLUG  
V.35  
SIGNAL  
MS34  
SOCKET  
SHIELD  
TD-A  
1
2
A
P
SHIELD  
TD-A  
TD-B  
RD-A  
RD-B  
TXC-A  
TXC-B  
RXC-A  
RXC-B  
RTS  
TD-B  
14  
3
S
RD-A  
R
T
RD-B  
16  
15  
12  
17  
9
TXC-A  
TXC-B  
RXC-A  
RXC-B  
RTS  
Y
AA  
V
X
4
C
D
F
CTS  
5
CTS  
RLSD  
DSR  
8
RLSD  
DSR  
6
E
SIG. COMMON  
TT-A  
7
B
SIG. COMMON  
TT-A  
24  
11  
20  
21  
18  
25  
U
W
H
N
L
TT-B  
TT-B  
DTR  
DTR  
RL  
RL  
LL  
LL  
TM  
NN  
TM  
495-14324-01  
Figure D-5. EIA 530A-to-V.35 Cable  
3360-A2-GB20-20  
December 1996  
D-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
ACCULINK 336x E1 NTU  
Table D-7  
V.35 Cable Interface  
CCITT  
Number  
Signal  
Direction  
Pin  
Shield  
A
B
Signal Common  
Transmitted Data  
102  
103  
To NTU  
P (A)  
S (B)  
Received Data  
104  
From NTU  
R (A)  
T (B)  
Request-to-Send  
Clear-to-Send  
105  
106  
To NTU  
C
D
F
From NTU  
From NTU  
From NTU  
To NTU  
Data Channel Received Line Signal Detector  
Data Set Ready  
109  
107  
E
H
Data Terminal Ready  
108/1, /2  
113  
Transmit Signal Element Timing (DTE Source)  
To NTU  
U (A)  
W (B)  
Transmit Signal Element Timing (DCE Source)  
Receiver Signal Element Timing (DCE Source)  
114  
115  
From NTU  
From NTU  
Y (A)  
AA (B)  
V (A)  
X (B)  
Local Loopback  
141  
140  
142  
To NTU  
L
N
Loopback/Maintenance  
Test Indicator  
To NTU  
From NTU  
NN  
D-10  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Pin Assignments  
EIA 530A-to-X.21  
Cable Interface  
530 DB25  
SIGNAL PLUG  
X.21  
SIGNAL  
DB15  
SOCKET  
TD-A  
TD-B  
2
14  
3
2
9
TD-A  
TD-B  
RD-A  
4
RD-A  
RD-B  
16  
17  
9
11  
6
RD-B  
RXC-A  
RXC-A  
RXC-B  
RTS-A  
RTS-B  
RLSD-A  
RLSD-B  
SIG. COMMON  
TT-A  
RXC-B  
13  
3
RTS-A  
4
RTS-B  
19  
8
10  
5
RLSD-A  
RLSD-B  
SIG. COMMON  
TT-A  
10  
7
12  
8
24  
11  
7
TT-B  
14  
TT-B  
495-14787  
Figure D-6. EIA 530A-to-X.21 Cable  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-11  
   
ACCULINK 336x E1 NTU  
Table D-8  
X.21 Cable Interface  
CCITT  
Number  
Signal  
Direction  
Pin  
Signal Common  
Transmitted Data  
102  
103  
8
To NTU  
2 (A)  
9 (B)  
Received Data  
104  
105  
109  
113  
115  
From NTU  
To NTU  
4 (A)  
11 (B)  
Request-to-Send  
3 (A)  
10 (B)  
Data Channel Received Line Signal Detector  
Transmit Signal Element Timing (DTE Source)  
Receiver Signal Element Timing (DCE Source)  
From NTU  
To NTU  
5 (A)  
12 (B)  
7 (A)  
14 (B)  
From NTU  
6 (A)  
13 (B)  
D-12  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Pin Assignments  
Power Input Connector  
Optional DC Power Cable  
The input power connector leads are shown in  
The power cable is a 14.5-foot, 18 AWG stranded  
cable. The connector is terminated at one end with a  
6-position connector. The other end of the cable is  
terminated with a bare wire that should be connected to a  
power source can be either a single source of +24 Vdc or  
up to two sources of 48 Vdc (A and B). You cannot  
connect +24 Vdc and 48 Vdc to the same unit. See the  
Table D-9  
DC Power Connector  
Signal  
Pin Number  
48 Vdc Return  
1, 2  
6
48 Vdc A  
48 Vdc B  
5
+24 Vdc  
5
+24 Vdc Return  
Chassis Ground  
4
3
Figure D-7. DC Power Cable  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-13  
       
ACCULINK 336x E1 NTU  
External Clock Interface  
The External Clock connector pinouts are in  
Table D-10  
External Clock Connector  
Signal  
Pin Number  
customer-supplied cable.  
Shield  
1
2
Clock (+) (RS422 only)  
Clock (–) (RS422 only)  
Clock In (RS423 only)  
Signal Common  
3
9
11  
Figure D-8. External Clock Connector  
D-14  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
SNMP MIB Objects  
E
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-1  
the implementation of the E1 NTU. The MIB II object  
groups supported or not supported by the 33xx Series  
devices are as follows:  
Overview  
This appendix describes the Management Information  
Base (MIB) objects that are supported by the E1 NTU and  
provides a correlation between front panel commands and  
MIB objects (Table E-1).  
System Group Supported.  
Interface  
Group  
Supported for the network  
interface, the G.703 DTE interface,  
the synchronous data ports, the  
COM port, and the AUX port.  
Interface statistics (counters) apply  
to any port (COM or AUX),  
whichever is defined as the SNMP  
management link.  
Management Information  
Base (MIB) II (RFC 1213)  
The objects defined by MIB II are organized into  
10 different groups. The E1 NTU implements only those  
groups where the semantics of the group are applicable to  
Address  
Translation  
Group  
Not supported since this group is  
not supported in MIB II.  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E-1  
   
ACCULINK 336x E1 NTU  
System Group – “sysObjectID” Object  
(system 2)  
IP Group  
Supported.  
ICMP Group Supported.  
This object provides the authoritative identification of  
the network management subsystem contained in the unit.  
This object displays the following object identifier:  
TCP Group  
Not supported since the TCP  
protocol is not supported by the  
E1 NTU.  
UDP Group  
EGP Group  
Supported.  
3360  
3364  
3365  
1.3.6.1.4.1.74.1.14.2.3.2  
1.3.6.1.4.1.74.1.14.2.3.3  
1.3.6.1.4.1.74.1.14.2.3.4  
Not supported since the EGP  
protocol is not supported by the  
E1 NTU.  
Transmission Supported on the E1 interfaces  
System Group – “sysServices” Object  
(system 7)  
Group  
using the DS1/E1 MIB. Supported  
on the synchronous data ports  
using the RS-232-like MIB.  
This object provides a value which indicates the set of  
services that are potentially offered by the E1 NTU. Only  
the following values are supported by the E1 NTU.  
Supported on the COM and AUX  
ports using the RS-232-like MIB.  
SNMP Group Supported.  
physical(1) – Layer 1 functionality for all  
interfaces.  
System Group, MIB II  
datalink/subnetwork(2) – Layer 2 functionality  
(SLIP, PPP) for the COM and AUX ports.  
The System Group objects are fully supported by the  
E1 NTU. The following sections provide clarification for  
objects contained in the System Group where it is not  
otherwise clear how the object definition in MIB II is  
related to the E1 NTU. Objects not mentioned are  
supported as stated in the MIB.  
internet(4) – Layer 3 functionality (IP) for all  
management links.  
end-to-end(8) – Layer 4 functionality (UDP) for all  
management links.  
Therefore, set this object to 15 (the sum  
of 1 + 2 + 4 + 8).  
System Group – “sysDescr” Object (system 1)  
This object provides the full name and version  
identification for the system hardware and software. This  
object displays the following string for 2-port and 4-port  
E1 NTUs (1-port E1 NTUs do not have H/W CCA2):  
Interface Group, MIB II  
The Interface Group consists of an object indicating the  
number of interfaces supported by the unit and an  
E1 HDSL NTU; model: xxxx-xx-xxx; S/W Release:  
yy.yy.yy; H/W CCA1: zzzz-zzz; H/W CCA2: zzzz-zzz;  
H/W CCA3: zzzz-zzz; Serial number: sssssss.  
interface table containing an entry for each interface. The  
E1 NTU provides an entry in the interface table for the  
network interface, the G.703 DTE interface, each of the  
synchronous data ports (1, 2, or 4 depending on the  
model), the COM port, and the AUX port, if they apply.  
The following sections provide clarification for objects  
contained in the Interface Group where it is not clear how  
the object definition in MIB II is related to the E1 NTU.  
Where:  
xxxx-xx-xxx represents the full model  
number of the unit.  
yy.yy.yy represents the software revision  
number of the unit.  
zzzz-zzz represents the hardware  
revision numbers of the unit.  
Interface Group – “ifNumber” Object  
(interfaces 1)  
sssssss represents the serial number of  
the unit.  
This variable contains the maximum number of MIB II  
supported interfaces possible across the 33xx Series  
product line (9). This is different from the MIB  
description, which is defined as the number of interfaces  
on the particular device. This change allows the use of the  
same ifIndexes across all 33xx Series models.  
E-2  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
   
SNMP MIB Objects  
The supported ifIndexes for the 3365 NTU are:  
Interface Group – “ifIndex” Object (ifEntry 1)  
Net E1  
This object provides the index into the ifTable and  
typically into tables in other MIBs also. The values of the  
ifIndex object do not vary between models even though  
not all indexes are supported for a particular model. When  
an unsupported index is accessed, “noSuchName” is  
returned.  
DTE E1  
COM port  
Auxiliary RS-232 port  
DCE port 1  
The following are the values of the ifIndexes for all  
33xx Series models:  
1 – Net E1  
Interface Group – “ifDescr” Object (ifEntry 2)  
2 – DTE E1  
This object provides the textual information about the  
interface. Each interface displays a text string as shown  
below:  
3 – COM port  
4 – (not used)  
5 – Auxiliary RS-232 port  
6 – DCE port 1  
7 – DCE port 2  
8 – DCE port 3  
9 – DCE port 4  
Network E1:  
DTE E1:  
COM:  
“Network E1. E1 HDSL NTU,  
Hardware Version: [CCA number  
for the CSU board]”.  
“DTE E1. E1 HDSL NTU,  
Hardware Version: [CCA number  
for the CSU board]”.  
“COM port. E1 HDSL NTU,  
Hardware Version: [CCA number  
for the CSU board]”.  
The supported ifIndexes for the 3360 NTU are:  
AUX:  
“AUX port. E1 HDSL NTU,  
Hardware Version: [CCA number  
for the CSU board]”.  
Net E1  
DTE E1  
Data Ports:  
“Data Port n. E1 HDSL NTU,  
Hardware Version: [CCA number  
for the DSU board]” (where n is 1  
to 4).  
COM port  
Auxiliary RS-232 port  
DCE port 1  
DCE port 2  
Interface Group – “ifType” Object (ifEntry 3)  
The supported ifIndexes for the 3364 NTU are:  
This object identifies the type of the interface based on  
the physical/link protocol(s) immediately below the  
network layer. Only the following values are supported by  
the E1 NTU:  
Net E1  
DTE E1  
COM port  
e1(19) – Used for the network and G.703 DTE  
interfaces.  
Auxiliary RS-232 port  
DCE port 1  
DCE port 2  
DCE port 3  
DCE port 4  
propPointToPointSerial(22) – Used for the  
synchronous data ports, and for the COM port when  
the port is not configured as the SNMP  
management interface.  
ppp(23) – Used for the AUX or COM port when  
the port is configured for PPP.  
slip(28) – Used for the COM port when the port is  
configured for SLIP.  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E-3  
ACCULINK 336x E1 NTU  
Interface Group – “ifMtu” Object (ifEntry 4)  
Interface Group – “ifOperStatus” Object  
(ifEntry 8)  
This object identifies the largest datagram that can be  
sent or received on the interface. It is applicable only to  
the interface configured as the SNMP management link.  
This object is zero for all other interfaces.  
This object specifies the current operational state of the  
interface. The value of this object for each interface is  
defined as follows:  
Network E1:  
The interface is up(1) when no  
alarm conditions exist.  
Interface Group – “ifSpeed” Object (ifEntry 5)  
This object provides the interface’s current bandwidth  
in bits per second. The value of this object for each  
interface is specified as follows:  
The interface is down(2) when an  
alarm condition is active.  
The interface is testing(3) when a  
test is active on the interface.  
E1 Interfaces:  
2,048,000 bps.  
DTE E1:  
The interface is up(1) when no  
alarm conditions exist and the  
interface is enabled.  
COM and  
AUX:  
The currently configured data rate  
for the port.  
The interface is down(2) when an  
alarm condition is active or the  
interface is disabled.  
Data Ports:  
The currently configured data rate  
for the port when the port is  
allocated to one of the E1  
interfaces or to another port as a  
backup. If the port is not allocated  
the data rate is defined as zero.  
The interface is testing(3) when a  
test is active on the interface.  
COM Port:  
AUX Port:  
Data Ports:  
When configured as an SNMP  
management link, up and down are  
based on the current state of the  
link layer protocol. Otherwise, the  
interface is always up(1).  
Interface Group – “ifAdminStatus” Object  
(ifEntry 7)  
The interface is never in the  
testing(3) state.  
This object specifies the desired state (configuration)  
of the interface. This object is supported only for the  
COM port. It provides the ability to switch between using  
the port for SNMP or ASCII operations. The value of this  
object will not affect the state of any of the interfaces on  
the E1 NTU other than the COM port. Only the following  
values are supported by the E1 NTU:  
When configured as an SNMP  
management link, up and down are  
based on the current state of the  
link layer protocol. Otherwise, the  
interface is always down(2).  
The interface is never in the  
testing(3) state.  
up(1) – The SNMP management link is active on  
the COM port.  
The interface is up(1) when the  
port is assigned to the E1 interface  
or another data port as a backup,  
and both CTS and DSR are ON.  
testing(3) – The SNMP management link is inactive  
on the COM port; the COM port can be used for  
proprietary ASCII functions.  
The interface is down(2) when the  
port is unassigned, or either CTS  
or DSR is OFF.  
The interface is testing(3) when a  
test is active on the interface.  
E-4  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
SNMP MIB Objects  
Interface Group – “ifLastChange” Object  
(ifEntry 9)  
IP Group, MIB II  
The IP Group objects are supported by the E1 NTU for  
all data paths which currently are configured to carry IP  
data to or from the E1 NTU, including the COM, AUX,  
EDL, and FDL. All of the objects in the IP Group other  
than the IP Address Translation table are fully supported.  
The IP Address Translation table (ipNetToMediaTable)  
does not apply to the E1 NTU and will be empty (i.e.,  
have zero entries). The following sections provide  
clarification for objects contained in the IP Group when it  
is not clear how the object definition in MIB II is related  
to the E1 NTU.  
This object contains the value of “sysUpTime” at the  
time the interface entered its current operational state. For  
the E1 NTU, this object is only updated for the “up” and  
“down” states. This is done since the “testing” state is not  
mutually exclusive with the “up” and “down” states.  
Interface Group – Input Counters  
(objects ifEntry 10 to ifEntry 15)  
These objects collect statistics on the data received by  
the COM port and the AUX port when these ports are  
configured as SNMP management links. For interfaces  
that are not configured as an SNMP management link,  
these statistics are not provided and an error status is  
returned if access is attempted. The objects used to collect  
input statistics are listed below:  
IP Group – “ipForwarding” Object (ip 1)  
This object specifies whether the unit is acting as an IP  
gateway in respect to the forwarding of a datagram  
received by, but not addressed to, this unit. Only the  
following value is supported by the E1 NTU.  
ifInOctets (ifEntry 10)  
forwarding(1) – The unit is acting as a gateway.  
ifInUcastPkts (ifEntry 11)  
ifInNUcastPkts (ifEntry 12)  
ifInDiscards (ifEntry 13)  
ifInErrors (ifEntry 14)  
IP Group – “ipAddrTable” Object (ip 20)  
The address table is supported by the E1 NTU.  
ifInUnknownProtos (ifEntry 15)  
IP Group – “ipAdEntAddr” Object  
(ipAddrEntry 1)  
Interface Group – Output Counters  
(objects ifEntry 16 to ifEntry 21)  
The ipAdEntAddr object is an IP address supported by  
the device and serves as the index to the address table.  
Since indexes for tables must be unique, only one ifIndex  
may be displayed for each IP address supported by the  
device. If you have configured the same IP address for  
multiple interfaces or for default IP addresses, you will  
not see all interfaces that support a particular IP address  
upon display of the ipAddrTable.  
These objects collect statistics on the data received by  
the COM port and the AUX port when these ports are  
configured as SNMP management links. For interfaces  
that are not configured as an SNMP management link,  
these statistics are not provided and an error status is  
returned if access is attempted. The objects used to collect  
output statistics are listed below:  
IP Group – “ipAdEntIfIndex” Object  
(ipAddrEntry 2)  
ifOutOctets (ifEntry 16)  
ifOutUcastPkts (ifEntry 17)  
ifOutNUcastPkts (ifEntry 18)  
ifOutDiscards (ifEntry 19)  
ifOutErrors (ifEntry 20)  
ifOutQLen (ifEntry 21)  
For some address table entries, the ipAdEntIfIndex  
object may have a value greater than ifNumber. In these  
cases, the ipAdEntIfIndex refers to a proprietary interface  
which is not currently implemented by the interface group  
of MIB II.  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E-5  
 
ACCULINK 336x E1 NTU  
The following read-only objects must not be specified  
in the set PDU used to add a route.  
IP Group – “ipRouteTable” Object (ip 21)  
The routing table used by the E1 NTU is supported as a  
read/write table. Entries in this table may be added,  
deleted, or changed. You should exercise great caution  
when adding or modifying routes in the ipRoutingTable.  
In general, it should not be necessary to add or modify  
routes in the E1 NTU. In those cases where it is deemed  
necessary, the routes should only be added to the  
connected device (i.e., the device closest to the  
destination). Internal routing mechanisms will propagate  
the route to the other devices.  
ipRouteProto – Set to netmgmt(3) by software.  
ipRouteAge – Defaulted to 999.  
ipRouteInfo – Set to OBJECT IDENTIFIER {0, 0}  
since it is unused.  
IP Group – “ipRouteDest” Object  
(ipRouteEntry 1)  
An existing route may be effectively deleted by setting  
the ipRouteType object to “invalid” for the entry to be  
deleted. An existing route may be modified by changing  
fields in the desired entry (indexed by ipRouteDest) of the  
routing table. A new route may be added by specifying  
values for a table entry for which the index  
The ipRouteDest object serves as the index to the  
routing table. Since indexes for tables must be unique,  
only one route per destination may appear in the table. To  
ensure that no duplicate destinations appear in the routing  
table, the ipRouteDest object of the ipRouteTable is  
treated as described in RFC 1354 (IP Forwarding Table  
MIB):  
(“ipRouteDest”) does not already exist.  
To add a route using an SNMP set, you must specify a  
group of minimal objects. These variable bindings must  
be contained in a single Protocol Data Unit (PDU). The  
objects are described in more detail in the following  
sections. The minimal set consists of:  
“The destination IP address of this route. An entry with  
a value of 0.0.0.0 is considered a default route. This object  
may not take a Multicast (Class D) address value. Any  
assignment (implicit or otherwise) of an instance of this  
object to a value x must be rejected if the bitwise  
logical–AND of x with the value of the corresponding  
instance of the ipForwardMask object is not equal to x.”  
ipRouteDest  
ipRouteIfIndex  
The following objects are defaulted if not specified in  
the set PDU used to add a route.  
IP Group – “ipRouteIfIndex” Object  
(ipRouteEntry 1)  
ipRouteMetric1 – Defaulted to 1 hop.  
When the routing table is displayed, the ipRouteIfIndex  
object for some entries may have a value greater than  
ifNumber. In these cases, the ipRouteIfIndex refers to a  
proprietary interface which is not currently implemented  
by the interface group of MIB II. Route entries with an  
unrecognized ipRouteIfIndex value should not be deleted.  
ipRouteMetric2 – Defaulted to –1 for standalone  
devices.  
ipRouteType – Defaulted to indirect.  
ipRouteMask – Defaulted as specified in the MIB  
description.  
When setting this object via SNMP, the ipRouteIfIndex  
value can only assume an appropriate value of ifIndex  
defined for the particular device type.  
The following objects are unused in the E1 NTU and  
setting them will have no effect on the operation of the IP  
implementation.  
IP Group – “ipRouteMetric2” Object  
(ipRouteEntry 4)  
ipRouteMetric3, ipRouteMetric4, ipRouteMetric5 –  
Defaulted to –1 as specified in the MIB.  
For standalone devices, ipRouteMetric2 is not used and  
contains –1.  
ipRouteNextHop – Defaulted to 0.0.0.0.  
When adding a route to the routing table using SNMP,  
do not specify a value for ipRouteMetric2.  
E-6  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
SNMP MIB Objects  
IP Group – “ipRouteProto” Object  
(ipRouteEntry 9)  
Transmission Group, MIB II  
Objects in the transmission group are supported on the  
network and G.703 DTE interfaces, the COM port, the  
AUX port, and the synchronous data ports. The objects in  
the transmission group are not defined within MIB II, but  
rather through other Internet standard MIB definitions.  
The following two transmission group objects are  
supported by the E1 NTU.  
This object is a read-only object and may have the  
following values in the E1 NTU.  
other(1) – Temporary route added by IP.  
local(2) – Route added or modified as a result of  
user configuration via the front panel.  
ds1 (transmission 18) – The transmission object  
supported on the E1 interfaces.  
netmgmt(3) – Route added or modified by means of  
an SNMP set.  
rs232 (transmission 33) – The transmission object  
supported on the synchronous data ports, COM  
port, and AUX port.  
icmp(4) – Route added or modified by Internet  
Control Management Protocol (ICMP).  
rip(8) – Route added or modified by the Routing  
Information Protocol (RIP) or similar proprietary  
protocol.  
The “ds1” transmission object is defined by the  
DS1/E1 MIB. The rs232 transmission object is defined by  
the RS-232-like MIB.  
IP Group – “ipRouteAge” Object  
(ipRouteEntry 10)  
SNMP Group, MIB II  
The SNMP Group objects that apply to a management  
agent are fully supported by the E1 NTU. The following  
objects apply only to an NMS and return a zero value if  
accessed.  
This object is implemented as a read-only object in the  
E1 NTU. In the E1 NTU, it reflects the value of the  
route’s time-to-live (in seconds). When displayed, a value  
of 999 represents a route that is retained permanently. For  
temporary routes, the ipRouteAge object decrements over  
time. All routes added via an SNMP set of the  
ipRouteTable are considered permanent routes. These  
routes do not age, but will remain unless deleted via  
SNMP.  
snmpInTooBigs (snmp 8)  
snmpInNoSuchNames (snmp 9)  
snmpInBadValues (snmp 10)  
snmpInReadOnlys (snmp 11)  
snmpInGenErrs (snmp 12)  
ICMP Group, MIB II  
snmpInGetResponses (snmp 18)  
snmpInTraps (snmp19)  
The ICMP Group objects are fully supported by the E1  
NTU.  
snmpOutGetRequests (snmp 25)  
snmpOutGetNexts (snmp 26)  
snmpOutSetRequests (snmp 27)  
snmpOutGetResponses (snmp 28)  
UDP Group, MIB II  
The User Datagram Protocol (UDP) Group objects are  
fully supported by the E1 NTU.  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E-7  
     
ACCULINK 336x E1 NTU  
Near End Group – “dsx1LineType” Object  
(dsx1ConfigEntry 5)  
DS1/E1 MIB (RFC 1406)  
The “ds1” object defined by RFC 1406 is supported for  
both the network and G.703 DTE interfaces. The DS1  
Near End Group and DS1 Fractional Group are supported  
for both interfaces. The DS1 Far End Group is not  
supported.  
This object corresponds to the NET Framing/DTE  
Framing configuration options for the E1 interfaces on the  
E1 NTU. Only the following values are supported by the  
E1 NTU.  
dsx1E1(4) – Indicates non-CRC-4 framing.  
dsx1E1-CRC(5) – Indicates CRC-4 framing.  
Near End Group, DS1/E1 MIB  
The DS1 Near End Group consists of the following  
four tables:  
Near End Group – “dsx1LineCoding” Object  
(dsx1ConfigEntry 6)  
DS1 Configuration  
DS1 Current  
DS1 Interval  
DS1 Total  
This object corresponds to the DTE Coding  
configuration option on the E1 NTU. Only the following  
values are supported by the E1 NTU.  
dsx1HDB3(3) – Indicates HDB3 line coding.  
All four tables are fully supported for the network  
interface. Since statistics are not kept for the G.703 DTE  
interface, only the DS1 Configuration table is fully  
supported. The “statistic” objects for the G.703 DTE  
interface entry in the DS1 Current, DS1 Interval, and DS1  
Total tables are always zero (null). The following sections  
provide clarification for objects contained in the Near End  
Group when it is not clear how the object definition in the  
DS1/E1 MIB is related to the E1 NTU.  
dsx1AMI(5) – Indicates AMI line coding (for DTE  
only, not available for NET).  
Near End Group – “dsx1SendCode” Object  
(dsx1ConfigEntry 7)  
This object specifies the test patterns/codes being sent  
over the network interface. These tests are not supported  
on the G.703 DTE interface. Only the following values  
are supported by the E1 NTU.  
Near End Group – “dsx1TimeElapsed” Object  
(dsx1ConfigEntry 3)  
dsx1SendNoCode(1) – Specifies that the interface  
is sending normal or looped data. Setting the  
interface to this value stops an active “send pattern”  
test on the interface. This is the only value  
supported by the G.703 DTE interface.  
Applies to the network interface only. An error status is  
returned if access is attempted for the G.703 DTE  
interface.  
dsx1SendOtherTestPattern(8) – Specifies that the  
network interface is sending a 1-in-8 or a 32767 test  
pattern. This value is read-only. An attempt to write  
this value returns a badValue response.  
Near End Group – “dsx1ValidIntervals” Object  
(dsx1ConfigEntry 4)  
Applies to the network interface only. An error status is  
returned if access is attempted for the G.703 DTE  
interface.  
Near End Group – “dsx1CircuitIdentifier” Object  
(dsx1ConfigEntry 8)  
This object is only supported on the network interface.  
E-8  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
   
SNMP MIB Objects  
Near End Group – “dsx1LoopbackConfig”  
Object (dsx1ConfigEntry 9)  
Near End Group – “dsx1SignalMode” Object  
(dsx1ConfigEntry 11)  
This object specifies the loopback state of the E1  
interfaces. Only the following values are supported by the  
E1 NTU.  
This object specifies whether time-slot 16 (TS16) is  
reserved for signaling. Only the following values are  
supported by the E1 NTU.  
dsx1NoLoop(1) – The E1 interface is not in a  
loopback state.  
none(1) – No signaling is being used on this  
interface.  
dsx1PayloadLoop(2) – Specifies that a Payload  
Loopback (PLB) is active for the network interface  
or a Repeater Loopback (RLB) is active for the  
G.703 DTE interface.  
bitOriented(3) – Indicates that TS16 is using  
Channel-Associated Signaling.  
messageOriented(4) – Indicates that TS16 is  
reserved for signaling.  
dsx1LineLoop(3) – Specifies that a Line Loopback  
(LLB) is active for the network interface or a DTE  
Loopback (DLB) is active for the G.703 DTE  
interface.  
Changing from none(1) to bitOriented(3) or  
messageOriented(4) deallocates all DS0 channels on the  
G.703 DTE and network interfaces.  
Near End Group – “dsx1TransmitClockSource”  
Object (dsx1ConfigEntry 12)  
Near End Group – “dsx1LineStatus” Object  
(dsx1ConfigEntry 10)  
This object specifies the timing source for the currently  
active transmit clock for this E1 interface. This may be  
either the primary clock source, secondary clock source (if  
the primary has failed), or the internal clock (if both  
primary and secondary have failed). This object differs  
from the MIB definition in that it is “read-only” (not  
read/write) for E1 NTUs. Only the following values are  
supported by the E1 NTU.  
This object specifies the line (alarm) status of the E1  
interfaces. Only the following values are supported by the  
E1 NTU. More than one value may be active at a time.  
dsx1NoAlarm(1) – No alarm present.  
dsx1RcvFarEndLOF(2) – A Remote Alarm  
Indication (RAI) signal is being received.  
dsx1RcvAIS(8) – An Alarm Indication Signal  
(AIS) is being received.  
loopTiming(1) – The recovered receive clock is  
being used as the transmit clock.  
dsx1LossOfFrame(32) – An Out Of Frame (OOF)  
condition has persisted for more that 2.5 seconds.  
localTiming(2) – The E1 NTU’s internal clock is  
being used as the transmit clock.  
dsx1LossOfSignal(64) – A Loss of Signal (LOS)  
condition has persisted for more that 2.5 seconds.  
ThroughTiming(3) – The recovered receive clock  
from another interface (e.g., E1, Port, or External)  
is being used as the transmit clock.  
dsx1LoopbackState(128) – The near end of the E1  
interface is in a loopback state.  
dsx1RcvFarEndLOMF(512) – The far end is  
sending a Loss of MultiFrame Failure (RMA).  
Near End Group – “dsx1Fdl” Object  
(dsx1ConfigEntry 13)  
dsx1XmtFarEndLOMF(1024) – The near end is  
sending a Loss of MultiFrame Failure (MFA).  
This object specifies how Facility Data Link is being  
used. Only the following values are supported by the  
E1 NTU. More than one value may be active at a time.  
dsx1Other Failure(4096) – An Excessive Error Rate  
(EER) has been detected on the network interface.  
dsx1other(1) – SNMP data is being sent over FDL.  
dsx1Fdl-none(8) – Indicates that the device does  
not use FDL. This value is always returned for the  
G.703 DTE interface. It is also returned for the  
network interface when the FDL management link  
is disabled.  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E-9  
ACCULINK 336x E1 NTU  
dsx1TotalIndex – The index that identifies the E1  
interface.  
Near End Group – The DS1 Current Table  
Objects (dsx1CurrentEntry)  
dsx1TotalESs – The 24-hour total Errored Seconds.  
The following DS1 current table objects are provided  
for the network interface only. Objects in the table that are  
not listed are not supported and will return an error status  
if access is attempted.  
dsx1Total SESs – The 24-hour total Severely  
Errored Seconds.  
dsx1TotalUASs – The 24-hour total Unavailable  
Seconds.  
dsx1CurrentIndex – The index that identifies the E1  
interface.  
dsx1TotalBESs – The 24-hour total Bursty Errored  
Seconds.  
dsx1CurrentESs – Errored Seconds for the current  
interval.  
dsx1Current SESs – Severely Errored Seconds for  
the current interval.  
Far End Group, DS1/E1 MIB  
dsx1CurrentUASs – Unavailable Seconds for the  
current interval.  
The DS1 Far End Group consists of the following three  
tables:  
dsx1CurrentBESs – Bursty Errored Seconds for the  
current interval.  
DS1 Far End Current  
DS1 Far End Interval  
DS1 Far End Total  
Near End Group – The DS1 Interval Table  
Objects (dsx1IntervalEntry)  
These tables are not supported for either the network or  
G.703 DTE interface.  
The following DS1 interval table objects are provided  
for the network interface only. Objects in the table that are  
not listed are not supported and will return an error status  
if access is attempted.  
The DS1 Fractional Group, DS1/E1 MIB  
The DS1 Fractional group consists of the DS1  
fractional table. This table (dsx1FracTable) is fully  
supported by the 336x NTUs and allows channel (time  
slots) to be mapped between the E1 interfaces and data  
ports. If an invalid channel map (e.g., two interfaces  
mapped to a single time slot, one interface mapped to two  
E1s, etc.) is received, an error is returned to the SNMP  
manager. The E1 NTU validates all channel  
dsx1IntervalIndex – The index that identifies the E1  
interface.  
dsx1IntervalNumber – The interval number  
(1 to 96).  
dsx1IntervalESs – Errored Seconds for the interval.  
dsx1Interval SESs – Severely Errored Seconds for  
the interval.  
configurations before applying them.  
Operational Note: The fractional E1 group only allows  
specification of an entire interface to a particular time slot  
on another interface (i.e., a time slot on one interface  
cannot be mapped to a time slot on another interface).  
This prevents complete mapping of time slots on the  
G.703 DTE interface to time slots on the network  
interface. For mapping time slots between the network  
and G.703 DTE interfaces, the following convention is  
used: Time slots on the E1 interface that are mapped to  
another E1 interface (i.e., not a data port) are connected in  
ascending order. For example, if the fractional table for  
the network interface maps time-slots 1, 3 and 5 to the  
G.703 DTE interface and the G.703 DTE interface maps  
time-slots 10, 11 and 15 to the network, the following  
time slots are connected: N1 to D10, N3 to D11, and N5  
to D15.  
dsx1IntervalUASs – Unavailable Seconds for the  
interval.  
dsx1Interval BESs – Bursty Errored Seconds for  
the interval.  
Near End Group – The DS1 Total Table Objects  
(dsx1TotalEntry)  
The following DS1 total table objects are provided for  
the network interface only. Objects in the table that are not  
listed are not supported and will return an error status if  
access is attempted.  
E-10  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
   
SNMP MIB Objects  
When time-slot 16 is reserved for signaling, allocated  
DTE channels must be mapped to the corresponding  
network channels (e.g., D1 to N1, etc.), otherwise an error  
is returned to the SNMP manager.  
(rs232PortTable). The values of the rs232PortIndex object  
vary between models and are listed below.  
The values of rs232PortIndex for the 3360 NTU are:  
1 – COM port  
When time-slot 16 is using Channel-Associated  
Signaling (CAS), allocated DTE channels can be mapped  
to any other corresponding network channels (e.g., D1 to  
N3, D5 to N7, etc.).  
2 – Auxiliary RS-232 port  
3 – DCE port 1  
4 – DCE port 2  
The values of rs232PortIndex for the 3364 NTU are:  
RS-232-like MIB (RFC 1317)  
1 – COM port  
The “rs232” object defined by RFC 1317 is supported  
for all of the synchronous data ports, the COM port, and  
the AUX port. The RS-232-like MIB consists of one  
object and five tables, as follows:  
2 – Auxiliary RS-232 port  
3 – DCE port 1  
Number of RS-232-like ports  
The General Port Table  
4 – DCE port 2  
5 – DCE port 3  
The Asynchronous Port Table  
The Synchronous Port Table  
The Input Signal Table  
6 – DCE port 4  
The values of rs232PortIndex for the 3365 NTU are:  
1 – COM port  
The Output Signal Table  
2 – Auxiliary RS-232 port  
3 – DCE port 1  
The Asynchronous Port table is not supported by the  
E1 NTU for the synchronous data ports. The Input Signal  
and Output Signal tables are not supported for the AUX  
and COM ports. The following sections provide  
clarification for objects contained in the RS-232-like MIB  
when it is not clear how the object definition in MIB is  
related to the E1 NTU.  
General Port Table – “rs232PortType” Object  
(rs232PortEntry 2)  
This object is used to identify the port’s hardware type.  
Only the following values are supported by the E1 NTU.  
other(1) – Used to identify synchronous data ports  
that are configured as X.21.  
Number of Ports – “rs232Number” Object  
(rs232 1)  
rs232(2) – Used to identify the AUX and COM  
ports.  
This object contains the number of ports in the  
RS-232-like general port table. This number is 3 for the  
3365 NTU, 4 for the 3360 NTU, and 6 for the 3364 NTU.  
rs422(3) – Used to identify synchronous data ports  
that are configured as EIA-530A or RS-449.  
v35(5) – Used to identify synchronous data ports  
that are configured as V.35.  
General Port Table, RS-232-like MIB  
The general port table contains general configuration  
objects for the RS-232-like interfaces.  
General Port Table – “rs232PortInSigNumber”  
Object (rs232PortEntry 3)  
General Port Table – “rs232PortIndex” Object  
(rs232PortEntry 1)  
This object contains the number of input signals  
contained in the input signal table. This is the number of  
signals that can be detected. This number is 2 for the  
This object contains a unique value for each port and is  
used as an index into the general port table  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E-11  
   
ACCULINK 336x E1 NTU  
synchronous data ports and 0 for the AUX and COM  
ports.  
Asynchronous Port Table, “rs232AsyncPortBits”  
(rs232AsyncPortEntry 2)  
This object specifies the number of bits in a character.  
Only the following values are supported by the E1 NTU.  
General Port Table – “rs232PortOutSigNumber”  
Object (rs232PortEntry 4)  
7 – 7-bit characters. Supported on the COM port  
only.  
This object contains the number of output signals  
contained in the output signal table. This is the number of  
signals that can be asserted. This number is 2 for the  
synchronous data ports and 0 for the AUX and COM  
ports.  
8 – 8-bit characters.  
Asynchronous Port Table,  
“rs232AsyncPortStopBits”  
(rs232AsyncPortEntry 3)  
General Port Table – “rs232PortInSpeed”  
Object (rs232PortEntry 5)  
This object specifies the number of stop bits supported.  
Only the following values are supported by the E1 NTU.  
This object contains the port’s input speed in bits per  
second. For the E1 NTU, the rs232PortInSpeed object has  
the same value as the rs232PortOutSpeed object. The  
input speed of a synchronous data port is determined by  
the channel configuration and cannot be changed through  
this object. Thus, for the synchronous data ports, this  
object is read-only. The input speed of the AUX or COM  
port is the currently configured speed. Setting of this  
value for the AUX or COM port causes the configured  
port speed to be changed.  
one(1) – One stop bit.  
two(2) – Two stop bits. Supported on the COM port  
only.  
one-and-half(3) – One and a half stop bits.  
Supported on the COM port only.  
Asynchronous Port Table,  
“rs232AsyncPortParity”  
(rs232AsyncPortEntry 4)  
General Port Table – “rs232PortOutSpeed”  
Object (rs232PortEntry 6)  
This object specifies the parity used by the port. Only  
the following values are supported by the E1 NTU.  
This object contains the port’s output speed in bits per  
second. For the E1 NTU, the rs232PortInSpeed object has  
the same value as the rs232PortOutSpeed object. The  
input speed of a synchronous data port is determined by  
the channel configuration and cannot be changed through  
this object. Thus, for the synchronous data ports, this  
object is read-only. The input speed of the AUX or COM  
port is the currently configured speed. Setting of this  
value for the AUX or COM port causes the configured  
port speed to be changed.  
none(1) – No parity bit.  
odd(2) – Odd parity. Supported on the COM port  
only.  
even(3) – Even parity. Supported on the COM port  
only.  
Asynchronous Port Table,  
“rs232AsyncPortAutoBaud”  
(rs232AsyncPortEntry 5)  
Asynchronous Port Table, RS-232-like MIB  
The asynchronous port table contains an entry for the  
AUX or COM port when the port is configured for  
asynchronous operation. For the E1 NTU, the entries in  
the table that are counters (rs232AsyncPortEntry 6–8) are  
used to collect statistics and are not supported.  
This object specifies the ability to automatically sense  
the input speed of the port. Only the following value is  
supported by the E1 NTU.  
disabled(2) – Autobaud is not supported.  
E-12  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
 
SNMP MIB Objects  
Synchronous Port Table, RS-232-like MIB  
Output Signal Table, RS-232-like MIB  
The synchronous port table contains an entry for each  
of the synchronous data ports and the COM port when the  
port is configured for synchronous operation. For the  
E1 NTU, the entries in the table that are counters  
(rs232SyncPortEntry 3–7) are used to collect statistics and  
are not supported.  
This object contains entries for the output signals that  
can be asserted by the unit for each of the synchronous  
data ports.  
Output Signal Table – “rs232OutSigName”  
(rs232OutSigEntry 2)  
Synchronous Port Table –  
“rs232SyncPortClockSource”  
(rs232SyncPortEntry 2)  
This object contains the identification of a hardware  
output signal. Only the following values are supported by  
the E1 NTU.  
cts(1) – Clear-To-Send.  
dsr(4) – Data Set Ready.  
This object specifies the clock source for the port. Only  
the following values are supported by the E1 NTU.  
internal(1) – The port uses an internal clock.  
external(2) – The port uses an external clock.  
Output Signal Table – “rs232OutSigState”  
(rs232OutSigEntry 3)  
Input Signal Table, RS-232-like MIB  
This object contains the current signal state. Only the  
following values are supported by the E1 NTU.  
This table contains entries for the input signals that can  
be detected by the unit for each of the synchronous data  
ports.  
on(2) – The signal is asserted.  
off(3) – The signal is not asserted.  
Input Signal Table – “rs232InSigName”  
(rs232InSigEntry 2)  
Output Signal Table – “rs232OutSigChanges”  
(rs232OutSigEntry 4)  
This object contains the identification of a hardware  
input signal. Only the following values are supported by  
the E1 NTU.  
This object is not supported by the E1 NTU.  
rts(1) – Request-To-Send.  
Generic-Interface Extension  
MIB (RFC 1229)  
dtr(4) – Data Terminal Ready.  
This generic-interface MIB is an experimental MIB  
that provides extensions to the generic interface group  
defined in MIB II. This MIB describes three tables:  
Input Signal Table – “rs232InSigState”  
(rs232InSigEntry 3)  
This object contains the current signal state. Only the  
following values are supported by the E1 NTU.  
Generic Interface Extension Table  
Generic Interface Test Table  
on(2) – The signal is asserted.  
Generic Receive Address Table  
off(3) – The signal is not asserted.  
Only the generic interface test table is supported by the  
E1 NTU. This table is supported for the network interface  
only.  
Input Signal Table – “rs232InSigChanges”  
(rs232InSigEntry 4)  
This object is not supported by the E1 NTU.  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E-13  
     
ACCULINK 336x E1 NTU  
testSend511 – Initiates a Send 511 test on the  
interface. Only supported for the data ports.  
Generic Interface Test Table, Generic  
Interface MIB  
testSendV54Up – Sends a V54 Up code to the  
remote unit. Only supported for the data ports.  
The test table provides access to additional tests  
(loopbacks and pattern tests) that are not in the interfaces  
group of MIB II.  
testSendV54Down – Sends a V54 Down code to  
the remote unit. Only supported for the data ports.  
Generic Interface Test Table – “ifExtnsTestType”  
Object (ifExtnsTestEntry 4)  
testSend32767 – Initiates a Send 32767 test on the  
network interface.  
testSend1in8 – Initiates a Send 1-in-8 test on the  
network interface.  
This object is a control variable used to start and stop  
operator-initiated tests on the interface. It provides the  
capability to:  
testMon32767 – Initiates a Monitor 32767 test on  
the network interface.  
Start/stop the Send 32767 test pattern on the  
network interface.  
Where these object identifiers are defined as follows:  
Start/stop the Send 1-in-8 test pattern on the  
network interface.  
noTest – OBJECT IDENTIFIER ::=  
[wellKnownTests 0]  
Start/stop the Send QRSS/511 test pattern on a  
synchronous data port.  
testFullDuplexLoopBack – OBJECT  
IDENTIFIER ::= [wellKnownTests 1]  
Start sending a V.54 UP/DOWN code to the remote  
unit for a synchronous data port.  
testLoopDTLB – OBJECT IDENTIFIER ::=  
[wellKnownTests 2]  
Start/stop the Monitor 32767 test pattern on the  
network interface.  
testMonQRSS – OBJECT IDENTIFIER ::=  
[wellKnownTests 3]  
Start/stop the Monitor QRSS/511 test pattern on a  
synchronous data port.  
testMon511 – OBJECT IDENTIFIER ::=  
[wellKnownTests 4]  
Start/stop the DCLB/DTLB loopback test on a  
synchronous data port.  
testSendQRSS – OBJECT IDENTIFIER ::=  
[wellKnownTests 5]  
The following object identifiers control tests on the  
interface.  
testSend511 – OBJECT IDENTIFIER ::=  
[wellKnownTests 6]  
noTest – Stops the test in progress on the interface.  
testSendV54Up – OBJECT IDENTIFIER ::=  
[wellKnownTests 7]  
testFullDuplexLoopBack – Initiates a DCLB on the  
interface. Only supported for the data ports.  
testSendV54Down – OBJECT IDENTIFIER ::=  
[wellKnownTests 8]  
testLoopDTLB – Initiates a DTLB on the interface.  
Only supported for the data ports.  
testSend32767 – OBJECT IDENTIFIER ::=  
[wellKnownTests 11]  
testMonQRSS – Initiates a Monitor QRSS test on  
the interface. Only supported for the data ports.  
testSend1in8 – OBJECT IDENTIFIER ::=  
[wellKnownTests 12]  
testMon511 – Initiates a Monitor 511 test on the  
interface. Only supported for the data ports.  
testMon32767 – OBJECT IDENTIFIER ::=  
[wellKnownTests 13]  
testSendQRSS – Initiates a Send QRSS test on the  
interface. Only supported for the data ports.  
E-14  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
 
SNMP MIB Objects  
Generic Interface Test Table –  
“ifExtnsTestResult” Object (ifExtnsTestEntry 5)  
Paradyne Enterprise MIB  
The variable devConfigAreaCopy under the  
This object contains the result of the most recently  
requested test. Only the following values are supported by  
the E1 NTU.  
devConfigAreaCopy group in the common area of the  
Paradyne Enterprise MIB will be supported. This variable  
allows the entire contents of one configuration area to be  
copied into another configuration area. Only the following  
values are supported by the E1 NTU.  
none(1) – No test currently active.  
inProgress(3) – A test is currently in progress.  
noOp(1) – An attempt to read this value returns a  
“noOp” response.  
notSupported(4) – The requested test is not  
supported.  
active-to-customer1(2) – Copy from the active area  
to the customer 1 area.  
unAbleToRun(5) – The requested test cannot run  
due to the state of the unit.  
active-to-customer2(3) – Copy from the active area  
to the customer 2 area.  
customer1-to-active(4) – Copy from the customer 1  
area to the active area.  
Generic Interface Test Table –  
“ifExtnsTestCode” Object  
(ifExtnsTestEntry 6)  
customer1-to-customer2(5) – Copy from the  
customer 1 area to the customer 2 area.  
This object contains a code that contains more specific  
information on the test result. This object is defined as an  
object identifier. Only the following values are supported  
by the E1 NTU.  
customer2-to-active(6) – Copy from the customer 2  
area to the active area.  
customer2-to-customer1(7) – Copy from the  
customer 2 area to the customer 1 area.  
none – No further information is available. Used for  
the send pattern/code and loopback tests.  
factory1-to-active(8) – Copy from the factory area  
to the active area. (There is only one factory area  
for the E1 NTU.)  
inSyncNoBitErrors – A monitor pattern (QRSS or  
511) test has synchronized on the pattern and has  
not detected any bit errors.  
factory1-to-customer1(9) – Copy from the factory  
area to the customer 1 area.  
inSyncWithBitErrors – A monitor pattern (QRSS or  
511) test has synchronized on the pattern and has  
detected bit errors.  
factory1-to-customer2(10) – Copy from the factory  
area to the customer 2 area.  
notInSync – A monitor pattern (QRSS or 511) test  
has not synchronized on the requested pattern.  
Where these object identifiers are defined as follows:  
wellKnownCodes – OBJECT IDENTIFIER ::=  
[ifExtensions 5]  
none – OBJECT IDENTIFIER ::=  
[wellKnownCodes 1]  
inSyncNoBitErrors – OBJECT IDENTIFIER ::=  
[wellKnownCodes 2]  
inSyncWithBitErrors – OBJECT IDENTIFIER ::=  
[wellKnownCodes 3]  
notInSync – OBJECT IDENTIFIER ::=  
[wellKnownCodes 4]  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E-15  
 
ACCULINK 336x E1 NTU  
panel and how the same function is accomplished using  
access to the SNMP database. SNMP objects are  
displayed in bold type while values for SNMP objects are  
displayed in italics.  
Correlation between Menu  
Commands and SNMP Objects  
function is performed or status is displayed on the front  
Table E-1  
(1 of 4)  
SNMP MIB to Front Panel Command Cross-Reference  
Front Panel Command  
SNMP MIB Object  
Stat–>DevHS:  
Read the dsx1LineStatus object for NET E1  
dsx1LossOfSignal  
dsx1LossOfFrame  
dsx1RcvFarEnd  
dsx1RcvAIS  
dsx1OtherFailure  
dsx1RcvFarEndLOMF  
dsx1XmtFarEndLOMF  
LOS at NET  
OOF at NET  
RAI at NET  
AIS at NET  
EER at NET  
RMA at NET  
MFA at NET  
Stat–>DevHS:  
Read the dsx1LineStatus object for DTE E1  
dsx1LossOfSignal  
dsx1LossOfFrame  
dsx1RcvFarEnd  
dsx1RcvAIS  
dsx1OtherFailure  
dsx1RcvFarEndLOMF  
dsx1XmtFarEndLOMF  
LOS at DTE  
OOF at DTE  
RAI at DTE  
AIS at DTE  
EER at DTE  
RMA at DTE  
MFA at DTE  
Stat–>Perf–>NET–>Cur:  
CurTimer  
Read the value in the following objects for NET E1  
dsx1TimeElapsed  
ES  
dsx1CurrentES  
UAS  
SES  
BES  
dsx1CurrentUAS  
dsx1CurrentSES  
dsx1CurrentBES  
Stat–>Perf–>NET–>Intvl–>Dsply:  
Select the interval number with dsx1IntervalNumber. Read the value  
in the following objects for NET E1  
dsx1IntervalES  
ES  
UAS  
SES  
BES  
VldIntvl  
dsx1IntervalUAS  
dsx1IntervalSES  
dsx1IntervalBES  
dsx1ValidIntervals  
Stat–>Perf–>NET–>24Tot:  
Read the value in the following objects for NET E1  
dsx1ValidIntervals  
dsx1TotalES  
VldIntvl  
ES  
UAS  
SES  
BES  
dsx1TotalUAS  
dsx1TotalSES  
dsx1TotalBES  
E-16  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
   
SNMP MIB Objects  
Table E-1  
(2 of 4)  
SNMP MIB to Front Panel Command Cross-Reference  
Front Panel Command  
SNMP MIB Object  
Stat–>Tstat:  
Read:  
LLB Test Active  
PLB Test Active  
RLB Test Active  
DLB Test Active  
DCLB on Port n  
DTLB on Port n  
32767 Test Active  
1–8 Test Active  
QRSS on Port n  
511 on Port n  
dsx1LineLoop from dsx1LoopbackConfig for Net E1  
dsx1PayloadLoop from dsx1LoopbackConfig for Net E1  
dsx1PayloadLoop from dsx1LoopbackConfig for DTE E1  
dsx1LineLoop from dsx1LoopbackConfig for DTE E1  
testFullDuplexLoopback from IfExtnsTestType for Port n  
testLoopDTLB from IfExtnsTestType for Port n  
testSend32767 from ifExtnsTestType for Net E1  
testSend1in8 from ifExtnsTestType for Net E1  
testSendQRSS from IfExtnsTestType for Port n  
testSend511 from IfExtnsTestType for Port n  
Mon QRSS, Port n  
Mon511, Port n  
Mon 32767, Net E1  
testMonQRSS from ifExtnsTestType for Port n  
testMon511 from ifExtnsTestType for Port n  
testMon32767 from ifExtnsTestType for Net E1  
Stat–>LED–>Prtn:  
Read:  
DTR  
CTS  
RTS  
rs232InSigState from rs232InSigName == dtr  
rs232outSigState from rs232OutSigName == cts  
rs232InSigState from rs232InSigName == rts  
Stat–>ID:  
Ser  
Mod  
SRev  
Read sysDescr object from the System Group  
HRevCCA1  
HRevCCA2  
HRevCCA3  
Test–>Rlpbk–>DCLBUP–>Prtn  
Test–>Rlpbk–>DCLBDN–>Prtn  
Set IfExtnsTestType for port n to testSendV54Up  
Set IfExtnsTestType for port n to testSendV54Down  
Test–>Lpbk–>LLB  
Set dsx1LoopbackConfig for NET E1 to dsx1LineLoop  
Test–>Lpbk–>Abort–>LLB  
Set dsx1LoopbackConfig for NET E1 to dsx1NoLoop  
Test–>Lpbk–>PLB  
Set dsx1LoopbackConfig for NET E1 to dsx1PayloadLoop  
Test–>Lpbk–>Abort–>PLB  
Set dsx1LoopbackConfig for NET E1 to dsx1NoLoop  
Test–>Lpbk–>DLB  
Set dsx1LoopbackConfig for DTE E1 to dsx1LineLoop  
Test–>Lpbk–>Abort–>DLB  
Set dsx1LoopbackConfig for DTE E1 to dsx1NoLoop  
Test–>Lpbk–>RLB  
Set dsx1LoopbackConfig for DTE E1 to dsx1PayloadLoop  
Test–>Lpbk–>Abort–>RLB  
Set dsx1LoopbackConfig for DTE E1 to dsx1NoLoop  
3360-A2-GB20-20  
December 1996  
E-17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCULINK 336x E1 NTU  
Table E-1  
(3 of 4)  
SNMP MIB to Front Panel Command Cross-Reference  
Front Panel Command  
SNMP MIB Object  
Test–>Lpbk–>DCLB–>Prtn  
Set IfExtnsTestType for port n to testFullDuplexLoopBack  
Test–>Lpbk–>Abort–>DCLB–>Prtn  
Set dsx1LoopbackConfig for port n to noTest  
Test–>Lpbk–>DTLB–>Prtn  
Set IfExtnsTestType for port n to testLoopDTLB  
Test–>Lpbk–>Abort–>DTLB–>Prtn  
Set dsx1LoopbackConfig for port n to noTest  
Test–>Ptrns–>Send–>QRSS–>Prtn  
Test–>Ptrns–>Abort–>Send–>Prtn  
Set IfExtnsTestType for port n to testSendQRS  
Set IfExtnsTestType for port n to noTest  
Test–>Ptrns–>Send–>32767  
Set ifExtnsTestType for NET E1 to testSend32767  
Test–>Ptrns–>Abort–>Send–>NET  
Set ifExtnsTestType for NET E1 to noTest  
Test–>Ptrns–>Send–>1in8  
Set ifExtnsTestType for NET E1 to testSend1in8  
Test–>Ptrns–>Abort–>Send–>NET  
Set dsx1SendCode for NET E1 to dsx1SendNoCode  
Test–>Ptrns–>Send–>511–>Prtn  
Test–>Ptrns–>Abort–>Send–>Prtn  
Set IfExtnsTestType for port n to testSend511  
Set IfExtnsTestType for port n to noTest  
Test–>Ptrns–>Mon–>QRSS–>Prtn  
Test–>Ptrns–>Abort–>Mon–>Prtn  
Set ifExtnsTestType for port n to testMonQRSS  
Set ifExtnsTestType for port n to noTest  
Test–>Ptrns–>Mon–>511–>Prtn  
Test–>Ptrns–>Abort–>Mon–>Prtn  
Set ifExtnsTestType for port n to testMon511  
Set ifExtnsTestType for port n to noTest  
Test–>Ptrns–>Mon–>32767–>NET  
Test–>Ptrns–>Abort–>Send–>NET  
Set ifExtnsTestType for NET E1 to testMon32767  
Set dsx1SendCode for NET E1 to dsx1SendNoCode  
Cnfig–>Load  
Cnfig–>Save  
Set devConfigAreaCopy to desired choice(Active to Customer1, etc.)  
Set/Display dsx1LineType for DTE E1 to dsx1E1 or dsxE1-CRC  
Set/Display dsx1LineCoding for DTE E1 to dsx1HDB3 or dsx1AMI  
Display rs232PortType for port n to rs422, v35, or X.21  
Cnfig–>Activ–>Edit–>DTE–>DTE–>Frame  
Cnfig–>Activ–>Edit–>DTE–>DTE–>Coding  
Cnfig–>Activ–>Edit–>Port–>Prtn->Port Type  
Cnfig–>Activ–>Edit–>Port–>Prtn–>TxClock  
Set/Display rs232SyncPortClockSource for port n to internal or  
external  
Cnfig–>Activ–>Edit–>NET–>NET Frame  
Cnfig–>Activ–>Edit–>NET–>Mgmt Link  
Set/Display dsx1LineType for NET E1 to dsx1E1 or dsxE1-CRC  
Set/Display dsx1Fdl for NET E1 to dsx1other or dsx1FDL-none  
E-18  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
SNMP MIB Objects  
Table E-1  
(4 of 4)  
SNMP MIB to Front Panel Command Cross-Reference  
Front Panel Command  
SNMP MIB Object  
Cnfig–>Activ–>Edit–>Chan–>DTE–>Assign  
Cnfig–>Activ–>Edit–>Chan–>DTE–>TS16  
Set/Display dsx1FracNumber and dsx1FracIfindex for DTE E1  
Display dsx1SignalMode for DTE E1 to none or bitOriented or  
messageOriented  
Cnfig–>Activ–>Edit–>Chan–>Prtn–>Assign To  
Cnfig–>Activ–>Edit–>Chan–>Dsply  
Set/Display dsx1FracNumber and dsx1Fracifindex for DTE E1 or  
NET E1  
Cnfig–>Activ–>Edit–>Chan–>Prtn–>Port Rate  
Display rs232PortInSpeed or rs232PortOutSpeed for port n  
Cnfig–>Activ–>Edit–>Gen–>Pri Clk Src  
Cnfig–>Activ–>Edit–>Gen–>Sec Clk Src  
Display dsx1TransmitClockSource for DTE E1 or NET E1 (Displays  
the active clock only)  
Cnfig–>Activ–>Edit–>User–>Com Rate  
Cnfig–>Activ–>Edit–>User–>Aux Rate  
Set/Display rs232PortInSpeed or rs232PortOutSpeed for COM or  
AUX port  
Cnfig–>Activ–>Edit–>User–>Char Length  
Cnfig–>Activ–>Edit–>User–>CParty  
Cnfig–>Activ–>Edit–>User–>CStop Bits  
Set/Display rs232AyncPortBits for COM port  
Set/Display rs232AyncPortParity for COM port  
Set/Display rs232AyncPortStopBits for COM port  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E-19  
 
IP Network Addressing Scenario  
F
Interconnected 33xx Series devices automatically  
Overview  
pass routing information between them; however, a  
static route to the subnet(s) must be set in the  
routing table of the NMS host. This route uses the  
33xx Series device connected to the LAN (via the  
LAN Adapter), or the NMS (via a direct PPP or  
SLIP connection) as a gateway to the subnet(s). In  
all instances, the addressing scheme presented  
works for both the LAN and the direct connections.  
This appendix describes a means of configuring 33xx  
Series devices in an Internet Protocol (IP) network to  
provide SNMP connectivity to a network management  
system (NMS). Since there are many possible network  
addressing schemes, this appendix describes an addressing  
scheme for a typical customer network scenario. This  
appendix is not intended to be an IP addressing or routing  
tutorial, and a basic understanding of IP and 33xx Series  
features is assumed.  
Although routing table entries are maintained  
automatically by 33xx Series devices, without the  
need for user configuration, only a maximum of  
100 routes is supported for a given device.  
IP Network Addressing  
The choice of a host address within a given subnet  
is completely arbitrary. Choose any legal host  
address for a given subnet, without regard to the  
local or remote devices.  
consists of a series of standalone 33xx Series devices  
daisy chained together, with remotes connected via the  
FDL. In this scenario, all 33xx Series devices are on the  
same subnet (135.18.1.0). The subnet mask for each  
device is FF.FF.FF.00. A static route is set in the NMS  
host to subnet 135.18.1.0.  
Although the default route (to the NMS) is  
configurable for all devices, only devices that have  
a direct external connection to an NMS (via the  
COM or AUX ports) need a default route set. In the  
following example, the default port (COM or AUX)  
is set in the device connected to the LAN Adapter.  
The following notes apply to this scenario:  
Connections to remote devices may be via EDL or  
FDL. Check with the service provider to be sure  
that the FDL is end-to-end (i.e., not terminated at  
an intermediate point within the network).  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
F-1  
       
ACCULINK 336x E1 NTU  
ETHERNET  
135.18.40.1  
135.18.1.2  
NETWORK  
135.18.1.3  
LAN  
ADAPTER  
SUBNET 135.18.40.0  
AUX/COM IP ADDRESS: 135.18.40.2  
135.18.1.4  
135.18.1.5  
SUBNET 135.18.1.0  
135.18.1.1  
135.18.1.7  
135.18.1.6  
496-14645-03  
Figure F-1. Daisy-Chained Standalone Devices at the Central Site  
F-2  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Front Panel Emulation  
G
Overview  
The E1 NTU offers functionality through Front Panel  
Emulation software that is similar to that provided by the  
E1 NTU front panel. The E1 NTU can either be locally or  
remotely attached to a 386 or higher PC that has at least  
4 MB of RAM. (An external modem is required for  
remote attachment.) A copy of the E1 NTU front panel  
appears on the PC. The functionality of the front panel is  
available by clicking on the Function keys with the mouse  
rather than by pressing keys from the actual front panel.  
4. Type the letter of the drive being used by the  
diskette, followed by a colon. Then,  
5. TYPE: INSTALL  
6. PRESS: ENTER  
Installing Front Panel  
Emulation Software  
7. An Information screen appears. Choose Continue  
to continue the installation.  
The Front Panel Emulation software is supplied on a  
3.5-inch, 1.44 MB, double-sided, high-density,  
write-protected diskette, with 15 sectors per track,  
80 tracks per side, and 96 tracks per inch.  
8. Type the letter of the destination drive, followed  
by a colon (default is C:), then the appropriate  
directory name (default is C:\FRONTPAN).  
This software must be installed on a 386 or higher PC  
with Microsoft Windows Release 3.1 or higher,  
MS-DOS 3.3 or higher, and at least 4 MB of RAM. A  
VGA color monitor with VGA adapter (or higher  
resolution) is required. A mouse is also required. The  
following procedures must be performed in the Windows  
environment.  
If the selected directory already exists, the  
following message appears: The specified  
directory already exists. Do you want to  
overwrite the directory?  
If the selected directory is new, the following  
message appears: The specified directory does  
not exist. Do you want to create the directory?  
To install Front Panel Emulation software,  
1. Insert the diskette into the appropriate drive.  
2. Select File from Program Manager.  
3. Choose Run.  
9. Select Yes. A confirmation screen appears. Select  
Install to continue the installation.  
10. A Setup Completed screen appears. Select  
Continue. The Program Manager screen appears  
with the Front Panel icon.  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
G-1  
       
ACCULINK 336x E1 NTU  
3. Double click on the Front Panel icon that appears  
after the Front Panel Emulation program is  
installed on the PC. The Front Panel Emulation  
screen appears.  
Starting Front Panel  
Emulation  
If the E1 NTU selected is not locally attached to the  
PC, you must first dial to the remote E1 NTU before  
starting front panel emulation. The modem attached to the  
PC must support AT commands for the Front Panel  
Emulation software to successfully place the call.  
To start front panel emulation,  
1. From the PC, open Program Manager from  
Windows.  
4. Enter the Com Port and Speed from the  
drop-down selection list boxes.  
The Com Port field needs to contain the actual  
communications port name as recorded in the  
Windows information file (INI).  
The Speed field needs to contain one of the  
following communications speeds: 1200, 2400,  
4800, 9600, 14400, 19200, or 38400 and should  
match the E1 NTU’s COM port configuration.  
2. The Front Panel Window opens.  
5. Choose either a Local (for near-end E1 NTU) or  
Remote (for far-end E1 NTU) destination.  
6. If you chose a Local destination, click on the  
Execute button. If you chose a Remote  
destination, enter the telephone number of the  
external modem connected to the far-end E1 NTU  
in the Phone Number field, then click on the Dial  
button.  
7. The front panel of the selected E1 NTU appears  
on the PC.  
NOTE  
When using Front Panel  
Emulation, no LEDs are shown on  
the PC’s screen; you must use  
the Stat command procedure to  
get LED information (see the  
section in Chapter 3, Operation).  
G-2  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3360-A2-GB20-20  
   
Equipment List  
H
Equipment  
Feature Number  
3360-A1-310  
3364-A1-310  
3365-A1-310  
3100-F1-550  
3100-F1-540  
3100-F1-520  
3100-C1-010  
3100-F1-580  
3100-F1-570  
3100-F1-571  
3100-F1-400  
COMCODE  
107699035  
107699043  
107699068  
406941542  
406941534  
406941492  
406942110  
107116543  
107116550  
107768103  
406941674  
Model 3360 E1 NTU  
Model 3364 E1 NTU  
Model 3365 E1 NTU  
Modular COM Port-to-PC Cable, 8-pin modular to DB9S  
COM Port-to-Terminal/Printer Cable, 8-pin modular to DB25P  
DC Power Cable  
Front Panel Emulation Software  
DB25 EIA 530A-to-RS449/422 Cable  
DB25 EIA 530A-to-V.35 Cable  
DB25 EIA 530A-to-X.21 Cable  
Wall-Mount/Rack-Mount Adapter  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
H-1  
   
Glossary  
Activ  
Active configuration area. The configuration option set that is currently active for  
the device. Before a configuration option set becomes active, you must save the set  
to the Active configuration area.  
adapter  
Hardware that provides some transitional function between two or more devices.  
A symbol (usually numeric) that identifies the interface attached to a network.  
address  
agent (SNMP)  
A software program housed within a device to provide SNMP functionality. Each  
agent stores management information and responds to the manager’s request for  
this information.  
aggregate  
AIS  
A single bit stream that combines two or more bit streams.  
Alarm Indication Signal. A signal transmitted instead of the normal signal to  
maintain transmission continuity and to indicate to the receiving device that a  
transmission fault exists.  
AMI  
Alternate Mark Inversion. A line coding technique used to accommodate the ones  
density requirements of E1 lines.  
application  
ASCII  
The use to which a device is put.  
American Standard Code for Information Interchange. A 7-bit code which  
establishes compatibility between data services.  
ASCII terminal/printer  
asynchronous data  
Devices that can be attached, either locally or remotely, to the E1 NTU to display or  
print alarm messages.  
Data transmission that is synchronized by a transmission start bit at the beginning  
of a character (five to eight bits) and one or more stop bits at the end.  
authenticationFailure trap  
An SNMP trap that indicates that the device has received an SNMP protocol  
message that has not been properly authenticated.  
AUX port  
AWG  
The auxiliary communications port on the E1 NTU.  
American Wire Gauge. An indication of wire size.  
bandwidth  
The range of frequencies that a circuit can pass. The greater the bandwidth, the  
more information that can be sent in a given amount of time.  
BES  
Bursty Errored Seconds. Seconds with more than one, but less that 805 CRC errors.  
bipolar signal  
A signal in which successive “ones” (marks, pulses) are of alternating, positive and  
negative polarity, and in which a “zero” (space, no pulse) is of zero amplitude.  
bit  
Binary digit. The smallest unit of information, representing a choice between a one  
or a zero (sometimes called mark or space).  
block allocation method  
A method of allocating DS0 channels as a group rather than individually.  
3360-A2-GB20-20  
December 1996  
Glossary-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ACCULINK 336x E1 NTU  
BNC  
bps  
Bayonet-Neill-Concelman. A bayonet-type connector for coaxial cables.  
Bits per second. Indicates the speed at which bits are transmitted across a data  
connection.  
BPV  
Bipolar Violation. In a bipolar signal, a “one” (mark, pulse) which has the same  
polarity as its predecessor.  
byte  
CAS  
A small group of bits (usually 8) that is handled as a unit of data.  
Channel-Associated Signaling. Time-slot 16 is reserved for signaling in a 16-frame  
multiframe system. With the exception of time-slot 16, the other time slots do not  
need to be directly connected as they are in Common-Channel Signaling (CCS).  
CCITT  
CCS  
The International Consultative Committee for Telegraphy and Telephony. (It is now  
renamed as the ITU.)  
Common-Channel Signaling. Time-slot 16 is reserved for signaling in a 2-frame  
multiframe system. The time slots must be directly connected so that the G.703  
DS0 channels are connected to the corresponding network DS0 channels (e.g., D1  
to N1, D2 to N2, etc.).  
CD  
Carrier Detect. The received line signal detector. V.24 circuit 109.  
CEPT  
The European Conference of Postal and Telegraph Authorities. A European  
standards organization.  
channel  
An independent data path.  
channel allocation  
Assigning specific DS0 channels in the E1 NTU to specific interfaces (HDSL  
Network, G.703 DTE, etc.).  
CHAP  
Challenge Authentication Protocol.  
character  
CID branch  
client  
A letter, figure, number, punctuation, or other symbol.  
Customer Identification branch or the E1 NTU menu tree.  
A device that receives a specific service, such as database management, from a  
server.  
CLOCK IN interface  
ClrReg branch  
Cnfig branch  
The external clock interface on the E1 NTU.  
Clear Performance Registers branch of the E1 NTU menu tree.  
Configuration branch of the E1 NTU menu tree.  
coaxial cable  
A transmission cable consisting of a conducting outer tube which encloses and is  
insulated from an inner conducting core.  
coding  
A technique used to accommodate the ones density requirements of E1 lines.  
A code used when ordering parts.  
COMCODE  
COM port  
The communications port on the E1 NTU.  
community name  
configuration  
An identification used by SNMP to grant an SNMP server access rights to a MIB.  
The arrangement of a system or network as defined by the characteristics of its  
functional units.  
configuration option  
Device firmware that establishes specific operating parameters for the device.  
Sometimes referred to as straps.  
control unit  
CPU fail  
A unit that exerts control over another unit.  
Central Processing Unit failure. A Self-Test Health message indicating a failure in  
the device’s central processing unit.  
Glossary-2  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Glossary  
CRC  
Cyclic Redundancy Check. A mathematical method of confirming the integrity of  
received digital data.  
CRC4  
CRC5  
CRC6  
CSA  
CRC using four check bits.  
CRC using five check bits.  
CRC using six check bits.  
Canadian Standards Association.  
CSU  
Channel Service Unit. Protects the E1 line from damage and regenerates the E1  
signal.  
Ctrl branch  
CTS  
Control branch of the E1 NTU menu tree.  
Clear-to-Send. V.24 circuit 106.  
Cust1  
Customer 1 configuration area. The first of two sets of customer-defined  
configuration options.  
Cust2  
Customer 2 configuration area. The second of two sets of customer-defined  
configuration options.  
daisy chaining  
Connecting the COM port of one E1 NTU to the AUX port of another E1 NTU to  
provide SNMP connectivity.  
database  
data port  
An organized compilation of computerized data.  
The electrical interface between the E1 NTU and the synchronous data terminal  
equipment.  
DB15 connector  
DB25 connector  
DCE  
A 15-position connector used on cables or devices.  
A 25-position connector used on cables or devices.  
Data Circuit-terminating Equipment or Data Communications Equipment. A device  
which provides signal conversion for communication between the DTE and the  
network.  
DCLB  
Data Channel Loopback. Loops the data received from the network interface, for all  
DS0 channels allocated to the selected port, back to the network.  
default  
A preset value that is assumed to be correct unless changed by the user.  
DevFail  
Device Failure. A message that indicates that an internal failure has been detected  
by the operating firmware. An 8-digit code appears for use by service personnel.  
DevHS branch  
device  
Device Health and Status branch of the E1 NTU menu tree.  
A mechanical, electrical, or electronic unit with a special purpose.  
digital signal  
A signal composed of discrete elements (zeros and ones) instead of a great  
multitude of analog elements.  
diskette  
DLB  
A thin, flexible magnetic disk enclose in a protective jacket.  
DTE Loopback. Loops the received signal on the G.703 DTE port back to the DTE  
without change.  
DL branch  
download  
Download branch of the E1 NTU menu tree.  
A process that transfers device firmware from a locally-attached PC to a device, or  
allows the duplication of firmware from a local device to a remote device.  
downstream device  
drop/insert  
A device that is connected farther from the host computer.  
An interconnection point for terminals, multiplexers, and transmission facilities.  
Individual channels may be inserted into the aggregate stream or dropped out to  
accommodate specific applications.  
3360-A2-GB20-20  
December 1996  
Glossary-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCULINK 336x E1 NTU  
DSR  
Data Set Ready. V.24 circuit 107.  
DS0  
Digital Signal Level 0. A 64 kbps standard signal or channel.  
DS0 channel allocation  
Assigning specific DS0 channels in the E1 NTU to specific interfaces (HDSL  
Network, G.703 DTE, etc.).  
DS1/E1 MIB  
DTE  
Defines objects for managing E1 interfaces and supports the network and G.703  
DTE interfaces on the E1 NTU.  
Data Terminal Equipment. The equipment, such as a computer or terminal, that  
provides data in the form of digital signals.  
DTLB  
Data Terminal Loopback. Loops the data received from the selected port, for all  
DS0 channels allocated to the port, back out the port.  
DTR  
EDL  
Data Terminal Ready. V.24 circuit 108/1, /2.  
Embedded Data Link. The 8 kbps in-band performance channel that provides  
4 kbps of user bandwidth for the support of an SNMP management link.  
EER  
EIA  
Excessive Error Rate. An error rate that is greater than the threshold in the E1 NTU.  
Electronic Industries Association. An organization providing standards for the data  
communication industry.  
EIA 530A  
An EIA standard for a high-speed, 25-position, DCE/DTE interface.  
MIB objects unique to Paradyne devices.  
Enterprise MIB  
enterprise-specific trap  
error  
A trap unique to Paradyne devices.  
A discrepancy between a measured or computed value or condition and the true or  
specified value or condition.  
ES  
Errored seconds. Seconds with one or more error events.  
ESD  
Electrostatic discharge. An undesirable discharge of static electricity that can  
damage equipment and degrade electrical circuitry.  
ETSI  
E1  
European Telecommunications Standardization Institute. An organization that  
produces technical standards in the area of telecommunications.  
A wideband digital interface operating at 2.048 Mbps defined by CCITT standards  
G.703 and G.704.  
Fact  
Factory configuration area. A configuration option set that is preset at the company  
(read-only options).  
failure  
fault  
An uncorrected hardware error.  
An accidental condition that causes a functional unit to fail to perform its required  
function.  
FCC  
FDL  
Federal Communications Commission. A board of commissioners that regulates  
electrical communication systems that originate in the United States.  
Facility Data Link. The selected framing bits in a wide-area link that are used for  
control, monitoring, and testing.  
FEBE  
Far-End Block Error. Block errors reported by remote equipment.  
Fractional E1  
Individual DS0 channels that may be sold separately or in groups to provide  
bandwidth that is some fraction of the total E1 capability.  
frame  
One identifiable group of bits that includes a sequence of bits for control,  
framing, etc.  
frame relay  
A switching interface that is designed to get frames from one part of the network to  
another as quickly as possible.  
Glossary-4  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Glossary  
framing  
A technique that separates bits into identifiable groups.  
Generic-Interface Extension  
MIB  
An extension to MIB II that defines additional objects for control of generic  
interfaces in MIB II.  
Get command (SNMP)  
ground  
Read-only access to SNMP MIB objects.  
A physical connection to earth or other reference point.  
G.703  
The ITU (formerly CCITT) standard for the physical and logical characteristics of  
transmissions over digital circuits.  
G.703 DTE interface  
G.704  
The G.703 interface on the rear panel of the E1 NTU.  
The ITU (formerly CCITT) standard for the physical and electrical characteristics  
of digital interfaces.  
HDB3  
HDLC  
HDSL  
High Density Bipolar Three Zeros Substitution. A line coding technique used to  
accommodate the ones density requirements of E1 lines.  
High-level Data Link Control. A communications protocol defined by the  
International Standards Organization (ISO).  
High bit-rate Digital Subscriber Line. A technique that allows high bit-rate (E1)  
digital signals to be transmitted over subscriber (local loop) lines.  
host  
Hz  
A computer system used for application processing on a network.  
Hertz. A unit of frequency that equals one cycle per second.  
ICMP  
Internet Control Management Protocol. The protocol that enables in-band control,  
diagnostic, and error messages to be passed between nodes in an IP internetwork.  
ID branch  
interface  
Internet  
Identity branch of the E1 NTU menu tree.  
A shared boundary between functional units.  
The worldwide interconnected collection of networks that predominantly use the  
TCP/IP protocol.  
internetwork  
IP address  
An interconnected collection of networks (also called an internet).  
Internet Protocol address. The address used by the SNMP manager to access the  
device.  
ISO  
ITU  
International Standards Organization.  
International Telecommunications Union. The telecommunications agency of the  
United Nations, established to provide standardized communications procedures  
and practices.  
kbps  
LAN  
Kilobits per second (thousand bits per second).  
Local Area Network. A network that spans a small geographic area (e.g., a  
building).  
LCD  
Liquid Crystal Display. Sealed glass plates containing liquid crystal material. When  
voltage is applied, the amount of light passing through the plates is altered so that  
messages may be displayed.  
LCP  
LED  
Link Control Protocol.  
Light-Emitting Diode. A status indicator that glows in response to the application of  
a voltage.  
link  
A communication path between two network nodes.  
link layer protocol  
The protocol that regulates the communication between two network nodes.  
3360-A2-GB20-20  
December 1996  
Glossary-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCULINK 336x E1 NTU  
link trap  
LLB  
A trap that identifies the condition of the communications interface (linkDown or  
linkUp traps).  
Line Loopback. Loops the received signal on the network interface back to the  
network without change.  
local loop  
A twisted-wire-pair cable that connects the subscriber’s premises to the local  
switching office.  
LOF  
Loss Of Frame. The inability to maintain frame synchronization.  
Loss Of Frame Count. A count of the number of LOFs declared.  
LOFC  
loopback test  
A test that verifies a device’s operation by connecting the device’s output to the  
device’s input.  
LOS  
Loss Of Signal. The E1 line condition where there are no pulses.  
Local Loopback branch of the E1 NTU menu tree.  
Link Quality Reports.  
Lpbk branch  
LQR  
LTU  
Line Termination Unit. The control unit on the network end of an HDSL link. (The  
NTU is on the customer end.)  
manager (SNMP)  
MB  
The device that queries agents for management information, or receives unsolicited  
messages (traps) indicating the occurrence of specific events.  
Megabytes. A unit of memory measurement equal to approximately one million  
bytes (typically 1,048,576 bytes).  
Mbps  
Megabits per second (million bits per second).  
menu tree  
A display of E1 NTU functions that are accessed by selecting various branches  
(Status, Test, etc.).  
MFA  
MIB  
Multiframe Alarm. A condition in which two consecutive multiframe alignment  
signals are received in error.  
Management Information Base. A database of managed objects used by SNMP to  
provide network management information.  
MIB II  
MIB Release 2. The current Internet-standard MIB.  
MRU  
Maximum Request Unit.  
module  
A compact assembly functioning as a component in a larger system or unit.  
An ordered, functional sequence of frames on a multiplexed digital circuit.  
To interleave or simultaneously transmit two or more messages on a single circuit.  
A configuration of data processing devices for information exchange.  
The HDSL Network interface connector on the rear panel of the E1 NTU.  
multiframe  
multiplex  
network  
network interface  
NMS  
Network Management System. A computer system used for monitoring and  
controlling network devices.  
node  
NTU  
A connection or switching point on the network.  
Network Termination Unit. The tributary unit on the customer end of an HDSL  
link. (The LTU is on the network end.)  
object (SNMP)  
OOF  
A specific item within a Management Information Base (MIB).  
Out Of Frame. An error condition in which frame synchronization bits are in error.  
option  
A hardware or software function that can be selected or enabled as part of a  
configuration process.  
PAP  
Password Authentication Protocol.  
Glossary-6  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Glossary  
parity  
A way of checking data accuracy by counting the number of bits that have a value  
of one.  
payload  
PBX  
The information bits in a frame.  
Private Branch Exchange. Telephone switching equipment dedicated to one  
customer. A PBX connects private telephones to each other and to the public  
network.  
PC  
Personal computer. In this document, references to a PC imply an IBM PC or an  
IBM-compatible PC.  
PDU  
PDV  
Protocol Data Unit. Used when adding routes in the Internet.  
Pulse Density Violation. The number of “ones” (marks, pulses) is not adequate for  
the line requirement.  
Perf branch  
PLB  
Performance Report branch of the E1 NTU menu tree.  
Payload Loopback. Loops the received signal on the network interface back to the  
network after it has passed through the framing circuity of the E1 NTU.  
port  
An access point for data entry or exit.  
PORT (14) interface  
POWER connector  
power-up self-test  
The synchronous data port interface on the E1 NTU.  
The power input connector on the E1 NTU.  
A test that checks most hardware components when power is applied to the device  
or a reset is initiated.  
PPP  
Point-to-Point Protocol. A link layer protocol used by SNMP.  
PRBS  
Psuedo-Random Bit Sequence. A test pattern containing any possible combination  
of digital ones and zeros for a given string length.  
primary clock  
PRM  
The primary timing source used to synchronize all of the E1 and data port interfaces  
on the E1 NTU.  
Performance Report Message. A message indicating performance data such as  
errored seconds, unavailable seconds, etc.  
protocol  
A set of rules that determines the behavior of functional units in achieving  
communication.  
Ptrns branch  
pulse density  
Test Patterns branch of the E1 NTU menu tree.  
A measure of the number of “ones” (marks, pulses) in relation to the total number  
of bits transmitted.  
QRSS Test  
Quasi-Random Signal Test. A test pattern simulating a random pattern of digital  
ones and zeros used to simulate normal transmission.  
RAI  
Remote Alarm Indication. A remote alarm on an E1 line.  
RAM  
Random-access memory. Read/write memory that is volatile and loses its contents  
when power is removed.  
register  
A part of the device’s memory that holds stored values.  
Release branch of the E1 NTU menu tree.  
Rel branch  
3360-A2-GB20-20  
December 1996  
Glossary-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCULINK 336x E1 NTU  
reset  
RFC  
A reinitialization of the E1 NTU that occurs at power-up or in response to a reset  
command.  
Request for Comments. The set of documents that describes the standard  
specifications for the TCP/IP protocol suite.  
RIP  
Routing Information Protocol. A protocol used to add routes in the Internet.  
An 8-position modular connector.  
RJ48C  
RLB  
Repeater Loopback. Loops the signal being sent to the network back to the G.703  
DTE and data ports after it has passed through the framing circuitry of the E1 NTU.  
Rlpbk branch  
RMA  
Remote Loopback branch of the E1 NTU menu tree.  
Remote Multiframe Alarm. An indication of a Multiframe Alarm condition at a  
remote location.  
router  
A device that connects LAN segments.  
RS-232  
An EIA standard for a low-speed, 25-position, DCE/DTE interface.  
RS-232-like MIB  
Defines objects for managing RS-232-type interfaces and supports synchronous  
data ports and management communication ports on the E1 NTU.  
RS-449  
RTS  
An EIA standard for a general-purpose, 37-position, DCE/DTE interface.  
Request-to-Send. V.24 circuit 105.  
RX  
Receive. To obtain signals that have been transmitted.  
Receive Clock. V.24 circuit 115.  
RXC  
RXD  
Receive Data. V.24 circuit 104.  
secondary clock  
The secondary clock source used to provide timing to the E1 NTU when the  
primary clock fails.  
self-test  
A test that checks most hardware components when power is applied to the device  
or a reset is initiated.  
server  
SES  
A device that offers a specific service, such as database management, to a client.  
Severely Errored Seconds. For E1 data, seconds with 805 or more CRC errors or  
errored frame alignment signals; or one or more LOS, AIS, or OOF events.  
Set command (SNMP)  
Write access to SNMP MIB objects.  
SLIP  
Serial Line Internet Protocol. A link layer protocol used by SNMP.  
SNMP  
Simple Network Management Protocol. A generic network management system  
that allows the device to be managed by any industry-standard SNMP manager.  
Stat branch  
STest branch  
StEvnt  
Status branch of the E1 NTU menu tree.  
Self Test Health branch of the E1 NTU menu tree.  
Status Event Register. Records the occurrence of certain alarm conditions.  
subnet  
An IP addressing standard in which a portion of the host address can be used to  
create multiple network addresses that are logically a subdivision of the network  
address.  
subnet mask  
synchronous data  
TCP/IP  
An integer used with the IP address of the host to determine which bits in the host  
address are used in the subnet address.  
Data transmission that is synchronized by timing signals. Characters are sent at a  
fixed rate.  
Transmission Control Protocol/Internet Protocol. The dominant protocol in the  
worldwide Internet.  
Glossary-8  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Glossary  
time slot  
The allocated DS0 channel slot when DS0 channels are combined to form an  
aggregate bit stream.  
trap (SNMP)  
A notification message to the SNMP manager when an unusual event occurs on a  
network device, such as a reinitialization.  
tributary unit  
TStat branch  
TS16  
A unit that is under the control of another unit.  
Test Status branch of the E1 NTU menu tree.  
Time-slot 16. The time slot which may be reserved for signaling.  
Transmit. To send signals from a device.  
TX  
TXC  
Transmit Clock. V.24 circuit 114.  
TXD  
Transmit Data. V.24 circuit 103.  
UAS  
Unavailable Seconds. A count of 1-second intervals when service is unavailable.  
UDP  
User Datagram Protocol. A TCP/IP protocol describing how messages reach  
application programs within a destination computer.  
UL  
Underwriter’s Laboratories, Inc. An organization which promotes product safety.  
Volts alternating current.  
Vac  
Vdc  
Volts direct current.  
V.24  
A CCITT standard for a low-speed, 25-position, DCE/DTE interface.  
A CCITT standard for a high-speed, 34-position, DCE/DTE interface.  
A CCITT standard for local and remote diagnostic loopback tests.  
A CCITT standard for a data channel loopback (DCLB).  
A CCITT standard for a data terminal loopback (DTLB).  
Wide Area Network. A network that spans a large geographic area (e.g., a country).  
An SNMP trap that indicates that the device has reinitialized itself.  
External Transmit Clock. V.24 circuit 113.  
V.35  
V.54  
V.54 Loop 2  
V.54 Loop 3  
WAN  
warmStart trap  
XTXC  
X.21  
A CCITT standard for a high-speed, 15-position, DCE/DTE interface.  
1in8 Test  
A test pattern consisting of a one (1) followed by seven zeros (on the network  
only).  
2B1Q  
Two binary, one quaternary. A line coding technique that compresses two binary  
bits of data into one time state as a four-level code.  
511 Test  
32767 Test  
A pseudo-random bit sequence (PRBS) that is 511 bits long (on the data ports  
only). This is a PRBS 2 –1 test.  
9
A pseudo-random bit sequence (PRBS) that is 32,767 bits long (on the network  
15  
only). This is a PRBS 2 –1 test.  
3360-A2-GB20-20  
December 1996  
Glossary-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
A
C
abort  
cabling  
Chan (Channel) Configuration branch  
Activ (Active) configuration area  
addressing. See IP (Internet Protocol) addressing  
agent, SNMP, 1-2  
channel allocation  
AIS (Alarm Indication Signal) condition  
CID (Customer Identification) branch  
CLOCK IN interface  
Alarm Configuration branch  
clocking  
alarm messages. See messages, alarm  
allocation, DS0 channel. See channel allocation  
ClrReg (Clear Performance Registers) branch  
ASCII terminal/printer  
AUX Port  
Cnfig (Configuration) branch. See configuration options  
COM Port  
used with ASCII terminal/printer, 1-2, 2-8, 4-10  
community name  
configuration options  
B
BPV (Bipolar Violation) condition  
procedure for changing, 3-11–3-14  
tables  
3360-A2-GB20-20  
December 1996  
Index-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ACCULINK 336x E1 NTU  
E
EER (Excessive Error Rate) condition  
connectors, rear panel  
Embedded Data Link (EDL)  
Ctrl (Control) branch  
Cust1 (Customer 1) configuration area  
error messages. See messages, alarm  
Cust2 (Customer 2) configuration area  
cyclic redundancy check (CRC)  
F
Facility Data Link (FDL)  
Fact (Factory) configuration area  
failure analysis. See troubleshooting  
failure message  
front panel  
D
daisy chaining  
connectivity, 1-5, 2-3, 2-4  
data port. See PORT (1–4) interface  
database, SNMP, 1-2  
DevHS (Device Health and Status) branch  
Front Panel Emulation  
feature number, H-1  
DL (Download) branch  
DS0 channel allocation. See channel allocation  
DTE (G.703) interface. See G.703 DTE interface  
DTE Configuration branch  
G
G.703 DTE interface  
managed by SNMP, 1-2  
Index-2  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
Gen (General) Configuration branch  
liquid crystal display (LCD)  
LOF (Loss Of Frame) condition  
loopback  
H
HDB3 (High Density Bipolar 3) coding  
HDSL (High bit-rate Digital Subscriber Line) branch  
HDSL network. See network interface  
LOS (Loss Of Signal) condition  
Lpbk (Local Loopback) branch  
I
ID (Identity) branch  
indicators. See LEDs, front panel  
IP (Internet Protocol) addressing  
M
K
L
maintenance  
keypad  
manager, SNMP, 1-2  
messages  
LED Control branch  
LED Status branch  
LEDs, front panel  
alarm  
with ASCII terminal/printer, 1-2, 4-10  
status  
MFA (Multiframe Alarm) condition  
MIBs, SNMP. See SNMP, MIBs  
3360-A2-GB20-20  
December 1996  
Index-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCULINK 336x E1 NTU  
Port Configuration branch  
power input  
N
NET (Network) Configuration branch  
network interface  
power-up self-test  
primary clock  
problem determination. See troubleshooting  
protocol, link layer, 3-14, 3-16  
Ptrns (Test Patterns) branch  
O
P
OOF (Out Of Frame) condition  
options, strap. See configuration options  
Q
R
QRSS Test, 4-21  
RAI (Remote Alarm Indication) condition  
PDV (Pulse Density Violation) condition, 3-6  
Perf (Performance Report) branch  
rate  
Point-to-Point Protocol (PPP)  
PORT (14) interface  
rear panel  
connectors. See connectors, rear panel  
managed by SNMP, 1-2  
Rel (Release) branch  
reset  
Index-4  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
Reset branch  
status messages. See messages, status  
STest (Self-Test Health) branch  
Rlpbk (Remote Loopback) branch  
straps. See configuration options  
RMA (Remote Multiframe Alarm) condition  
synchronous data port. See PORT (1–4) interface  
RX network connector, 1-5  
T
temperature  
Test branch  
S
secondary clock  
self-test  
Serial Line Internet Protocol (SLIP)  
test jacks  
time-slot 16 (TS16)  
timing. See clocking  
SNMP (Simple Network Management Protocol)  
configuration options  
manager, 1-2  
MIBs  
traps, SNMP. See SNMP, traps  
troubleshooting  
traps  
TStat (Test Status) branch  
Stat (Status) branch  
TX network connector, 1-5  
3360-A2-GB20-20  
December 1996  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index-5  
ACCULINK 336x E1 NTU  
U
W
X
User Configuration branch  
V
V.54 Loop 2. See data channel loopback (DCLB)  
V.54 Loop 3. See data terminal loopback (DTLB)  
Index-6  
December 1996  
3360-A2-GB20-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

MTD Log Splitter 249 640A User Manual
NEC Home Theater System NP M260WJL User Manual
New Holland Lawn Mower 300GM Series User Manual
Nintendo Automobile Accessories APS 996a User Manual
Omega Engineering Clock Radio I 32 User Manual
Onkyo Stereo System SR803 User Manual
Oregon Clock Radio PE329 User Manual
Oregon Scientific Games 086L004850 017 User Manual
Oregon Scientific Microcassette Recorder VR355 User Manual
OWI Portable Speaker LR202 User Manual