Panasonic Ventilation Hood FV 05 11VK1 User Manual

Model No.  
FV-05-11VKS1  
FV-05-11VK1  
FV-11-15VK1  
Contents  
2-3  
GENERAL SAFETY INFORMATION  
PLEASE READ PRIOR TO INSTALLING THIS FAN  
DESCRIPTION  
4
4
4
UNPACKING  
5
SUPPLIED ACCESSORIES  
5
DIMENSIONS  
5
WIRING DIAGRAM  
FEATURE  
6
FV-05-11VKS1 FV-05-11VK1  
INDICATION (PLUG ‘N PLAY FUNCTION DEVICES)  
MOTION (PLUG ‘N PLAY FUNCTION DEVICES)  
INSTALLATION (PLUG ‘N PLAY FUNCTION DEVICES)  
INSTALLATION (NEW CONSTRUCTION)  
INSTALLATION (RETROFIT)  
MAINTENANCE (CLEANING)  
6-7  
7
8
8-10  
10  
11  
PRACTICAL GUIDE TO INSTALLATION  
SPECIFICATIONS  
BACK COVER  
BACK COVER  
BACK COVER  
PRODUCT SERVICE  
FV-11-15VK1  
Thank you for purchasing this Panasonic product.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING  
Canada only: Not to be installed in a ceiling thermally insulated to a value greater than R40.  
Do not disassemble the unit for reconstruction. It may cause fire or electric shock.  
When this product is no longer being operated, please remove the product to prevent the  
possibility of falling.  
Ceiling joist must be subjected to static load more than five times the weight of the product.  
Do not install with a method which is not approved in the instructions.  
Do not use this fan with any solid-state speed control device. Solid state controls may cause  
harmonic distortion which can cause motor humming noise.  
This product must be properly grounded.  
CAUTION  
Do not install this ventilating fan where interior room temperature may  
exceed 104°F(40°C).  
Make sure that the electric service supply voltage is AC 120V, 60Hz.  
Follow all local electrical and safety codes, as well as the National  
Electrical Code (NEC) and the Occupation Safety and Health Act (OSHA).  
Always disconnect the power source before working on or near the fan,  
motor or junction box.  
Protect the supply wiring from sharp edges, oil, grease, hot surfaces,  
chemicals or other objects.  
Adaptor  
Do not kink the supply wiring.  
Provide make up air for proper ventilation.  
For general ventilating use only. Do not use to exhaust hazardous or  
explosive materials and vapors.  
(Cooking area)  
Do not install the unit where ducts are configured as shown  
Do not install above or  
in Fig.A.  
inside this area  
Not for use in cooking area. (Fig.B)  
The special-purpose or dedicated parts, such as mounting  
fixtures, must be used if such parts are provided.  
Floor  
Cooking  
equipment  
Fig. B  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
PLEASE READ PRIOR TO INSTALLING THIS FAN  
Spot and Continuous Ventilation: These fans are designed to run continuously ensuring a healthy  
environment at low CFM levels 24 hours a day. By utilizing the optional CustomVent Multi-Speed  
module the fans are built to run continuously at a pre-set lower level (FV-05-11VKS1 and FV-05-11VK1:  
0, 30, 40, 50, 60, 70, 80, 90, 100 CFM; FV-11-15VK1: 0, 50, 60, 70, 80, 90, 100, 110, 120 CFM). The  
setting is dependent on the size of the house and the individual wishes of the homeowner. It is crucial  
that the installer pre-set the lower setting during the installation. Please refer to the chart below  
and the switch indication on page 6.  
CustomVent Multi-Speed module (Lower Setting). ASHRAE 62.2-2010  
(sq.feet)  
Two Bedrooms Three Bedrooms Four Bedrooms Five Bedrooms  
33  
38  
43  
48  
53  
58  
63  
68  
73  
78  
83  
88  
93  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
95  
100  
<1,000  
1,500  
2,000  
2,500  
3,000  
3,500  
4,000  
4,500  
5,000  
5,500  
6,000  
6,500  
7,000  
48  
53  
58  
63  
68  
73  
78  
83  
88  
93  
98  
103  
108  
55  
60  
65  
70  
75  
80  
85  
90  
95  
100  
105  
110  
These fans are also built to take care of the homeowner’s spot ventilation needs when the room is  
occupied. The basic fan models allow a choice of three speeds. When fans are equipped with the optional  
Multi-Speed module, these models kick up to a maximum level of 150 CFM for the FV-11-15VK1 and 110  
CFM for the FV-05-11VKS1 and FV-05-11VK1 either when the switch is turned on or activated by the  
optional Condensation Sensor module or the optional Motion Sensor module.  
A High/Low Delay Timer, located inside the fan unit, is utilized to return the fan back to the pre-set  
Continuous ventilation mode. The installer needs to consult with the homeowner for the desired  
setting on the timer (0 - 60 minutes) and make the adjustments during the installation.  
DESCRIPTION  
These products are listed by UL under UL file No. E78414.  
These products use a sirocco fan driven by a DC motor powered by an integral transformer. The motor is  
designed to have long operating life, high dynamic response, higher speed ranges with saving energy.  
The grille covering the fan body is a spring-loaded, quick remove type. A damper for preventing air counter  
flow is provided. The blower uses a high-capacity sirocco fan developed to reduce the noise level.  
UNPACKING  
Unpack and carefully remove the unit from carton.  
Refer to the Supplied Accessories list to verify that all parts are present.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
SUPPLIED ACCESSORIES  
Quantity  
Quantity  
1
Part name  
Appearance  
Part name  
Appearance  
Warranty  
sheet  
Grille  
1
Flex-Z FastTM  
bracket  
Tapping screw  
(ST4.2X20)  
1
2
4
4
Installation  
instructions  
Self-drilling  
screw  
DIMENSIONS  
Unit: inches (mm)  
FV-11-15VK1  
1 (26)  
7/8 (22.5)  
4
5/8 (116)  
10  
FV-05-11VK1  
FV-11-15VK1  
6
3/8 (163)  
7
3/8 (190)  
12  
11  
11  
FV-11-15VK1  
FV-05-11VKS1  
No.  
1
No.  
7
Part name  
Part name  
Connector cover  
Base PCB box  
13 (330)  
Blade  
Grille  
2
8
Motion sensor location  
(FV-MSVK1 not included)  
9
Pick-A-Flow switch  
3
10  
11  
4
5
Junction box  
Adaptor  
Fan body  
Damper  
Multi-Speed module  
(FV-05-11VKS1 only,  
Flex-Z FastTM bracket  
12  
6
3 7/8 (100)  
10 1/4 (260)  
3 7/8 (100)  
other models not included)  
WIRING DIAGRAM  
Junction box  
Fan body  
DC-Motor  
Switch for power  
(114°C Fuse)  
Live  
Black  
(Power supply)  
AC120V 60Hz  
Thermally  
protected  
Neutral  
White  
Multi-Speed module  
(FV-05-11VKS1  
Hi/Low switch: When plug in  
Multi-Speed module;  
On/Off switch: When plug in  
other Plug ‘N Play modules.  
only, other models  
not included)  
Red  
Red  
Plug ‘N Play module slot  
(Non-powered control wires)  
Plug ‘N Play module slot  
Green  
Earth ground  
Green  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
FEATURE  
[For models of: FV-05-11VKS1, FV-05-11VK1, FV-11-15VK1.]  
The WhisperGreen Select Line of ventilation fans employs innovative, state-of-the-art technologies that  
provide a number of customizable unique features that lead to improved indoor air quality. Please  
read the installation manual first in order to realize the benefits of this customizable, modular fan.  
Optimum Ventilation Performance:  
Duct length, elbows and other factors increase static pressure which can hinder the performance of most  
ventilation fans. This fan utilizes SmartFlow microchip technology that monitors the static pressure in the  
system and speeds up or slows down the rpm of the fan depending upon the amount of resistance within  
the ducts. This feature allows the fan to perform as rated and avoid potential installation issues.  
Outstanding Energy Savings:  
The WhisperGreen Select Line of fans are built using DC motor technology. The DC motor is 30% - 70%  
more energy efficient than the minimum ENERGY STAR requirements.  
Pick-A-Flow Feature  
All the WhisperGreen Select base models of fans come with Pick-A-Flow  
speed options. The Pick-A-Flow switch on the face of all WhisperGreen  
Select fans allows the option to choose 50 – 80 – 110 CFM for the  
FV-05-11VK1, FV-05-11VKS1 or 110 – 130 – 150 CFM for the  
FV-11-15VK1. These fans can run continuously or intermittently,  
depending upon the needs of the owner.  
Air volume type (CFM)  
Factory setting  
(
)
AIR VOLUME CFM  
05-11 50  
Pick-A-Flow  
switch  
80 110  
FV-05-11VKS1  
FV-05-11VK1  
MODEL  
50  
80  
110  
80 CFM  
11-15  
FV-11-15VK1  
110 130 150  
130 CFM  
MODEL110130150  
INDICATION (PLUG ‘N PLAY FUNCTION DEVICES)  
PLUG ‘N PLAY Modular Component Accessories  
Sold Separately, Not Included With Base Model Fan  
FV-VS15VK1 Multi-Speed module allows the fan to run continuously  
at lower speeds to maintain ventilation standards to meet Indoor  
Air Quality and then boost up to high speed to meet intermittent  
needs for ‘Spot’ or ‘Point Source’ exhaust needs. The FV-VS15VK1  
Modular Component will operate for both the FV-05-11VK1 and the  
FV-11-15VK1 matching the appropriate Multi-Speed setting shown  
below. The FV-05-11VKS1 comes with the FV-VS15VK1 Multi-Speed  
module. It is not necessary to purchase this component.  
Note the options on the face of the FV-VS15VK1 Multi-Speed module  
to choose appropriate levels of airflow (CFM) and time delay before  
returning back to low speed (TIME). Choosing the Pick-A-Flow setting  
automatically adjusts the Multi-Speed setting accordingly. As an  
example, if the Pick-A-Flow Multi-speed setting is 80 CFM, the  
Multi-Speed settings adjust automatically to be 0, 30, 40, 50, 60 or 70  
CFM at the lower speeds. The fan will ‘boost’ to the 80 CFM speed as  
the high speed setting. Selecting a particular TIME option will cause  
the fan to run for the selected amount of time before returning to  
the lower speed setting chosen on the CFM dial.  
Note that there is ONLY ONE  
Plug ‘N Play slot to insert the  
Multi-Speed module within the  
base model fan. There are TWO  
interchangeable Plug ‘N Play  
slots to insert the Condensation  
Sensor module, Motion Sensor  
module or Nite-GloTM LED Night  
Light module within the base  
model fan.  
Multi-Speed Air volume (CFM)  
Pick-A-Flow (CFM)  
50  
80  
110  
110  
130  
150  
0
0
0
0
0
0
30  
30  
30  
50  
50  
50  
40  
40  
40  
60  
60  
60  
40  
50  
50  
70  
70  
70  
40  
60  
60  
80  
80  
80  
40  
70  
70  
40  
70  
80  
40  
70  
90 100  
40  
70  
FV-05-11VKS1,  
FV-05-11VK1  
(plug-in FV-VS15VK1)  
90 100 100 100  
90 100 110 110  
90 100 110 120  
FV-11-15VK1  
(plug-in FV-VS15VK1)  
Delay Time (min)  
45  
Factory setting: 20 minutes.  
Delay Time position “0“ : Manual wall switch control is 0 minute;  
without manual wall switch control is 0.5 minute.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
INDICATION (PLUG ‘N PLAY FUNCTION DEVICES) CONTINUED  
PLUG ‘N PLAY Modular Component Accessories  
Sold Separately, Not Included With Base Model Fan  
FV-CSVK1 Condensation Sensor module turns the base fan on or  
boosts to higher speed when humidity is detected when used in  
combination with the FV-VS15VK1. The Condensation Sensor works  
based on calculations from the Psychrometric Chart, or combination  
of Relative Humidity (RH) and Temperature. This allows the fan to  
anticipate the formation of condensation and automatically turn on  
when needed to expel humid air. The Condensation Sensor is pre-set  
to run for 20 minutes; it will then check the RH and Temperature to  
detect if the fan needs to run for another 20 minutes cycle.  
FV-MSVK1 Motion Sensor module turns the base fan on or boosts  
to higher speed when motion is detected when using in combination  
with the FV-VS15VK1. The Motion Sensor is pre-set to run for 20  
minutes; it will then re-check for movement; if detected the fan will  
run for another 20 minutes cycle. The Motion Sensor detects within  
the range shown below.  
The distance that motion  
can be detected is limited  
to 10 feet (3m). The field  
of view of the sensor is 90°.  
(Room temperature is 25 C).  
FV-NLVK1 Nite-GloTM LED Night Light module automatically turns on  
when ambient light levels are met. Turning the dial on the Modular  
Nite-Glo Component to ‘DARK’ is ideal if the fan is in an isolated room  
with little ambient light from nearby rooms. Turning the dial to  
‘BRIGHT’ is ideal if there is light spill from nearby rooms. (Note that it is  
necessary to connect wall switch when only plug in FV-NLVK1, fan can  
operate on high speed with wall switch control, fan can also operate  
on low speed when used in combination with the FV-VS15VK1.)  
MOTION (PLUG ‘N PLAY FUNCTION DEVICES)  
PLUG ‘N PLAY Modular  
Components used in  
Combinations  
PLUG ‘N PLAY Modular Component Accessories  
Sold Separately, Not Included With Base Model Fan  
FV-CSVK1 + FV-MSVK1  
Turns the fan on for 20 minutes when either  
motion or excess humidity is detected.  
FV-CSVK1 + FV-VS15VK1  
Cycles the fan to high speed from low speed  
for the amount of time selected on the Control  
Dial based upon detection of excess humidity.  
FV-MSVK1 + FV-VS15VK1  
Cycles the fan to high speed from low speed  
for the amount of time selected on the Control  
Dial based upon motion within the room.  
Fan  
Time delay  
operation  
Motion  
Human  
active  
operation  
FV-CSVK1 only  
Fan  
ON/OFF  
20 minutes  
time delay  
When motion or  
excess humidity is  
detected, fan runs the delay time has  
at high speed. passed.  
Remains running  
at high speed until  
FV-MSVK1 only  
Fan  
active  
At low  
speed  
Depend on  
FV-VS15VK1 Time  
delay setting  
FV-CSVK1 + FV-VS15VK1  
FV-MSVK1 + FV-VS15VK1  
Fan  
Hi/Low speed  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION (PLUG ‘N PLAY FUNCTION DEVICES)  
You can purchase the specified Plug ‘N Play devices that are explained on page 6-7 and install them in positions  
2
3
,
and  
. Position  
can only be used with Multi-Speed module (model FV-05-11VKS1 already have  
and can be used for any of the other optional control modules.  
this control installed), position  
2
3
1. Remove the connector cover from position  
, 2 or 3 .  
2. Plug in the specified devices to Base PCB box and fix to the slot, till hear the sound installed in place.  
Connector  
cover  
Base PCB box  
Slot  
2
2
3
3
Clasp  
Squeeze tabs on the Clasp to  
remove. Squeeze, insert and  
release the tabs on Clasp to replace.  
INSTALLATION (NEW CONSTRUCTION)  
The fan position between joists from 16" to 24"  
on center can be adjusted flexibly.  
Adaptor  
Machine screw  
(M4X6)  
CAUTION  
Please wear gloves during the installation  
work as follow.  
Fig.1  
Fan body  
1. Disconnet plug connector from receptacle and  
remove adaptor from fan body by removing the  
machine screw (M4X6) before installation. (Fig.1)  
Joist  
IMPORTANT:  
Remove the tape from damper and adaptor  
before installation. As shown below:  
Bend down  
4 tabs  
Adaptor  
Damper  
2 Tapping screws  
(ST4.2X20)  
Fig.2  
Tape  
Joist  
2. Bend down 4 tabs for positioning, install the  
Flex-Z FastTM bracket to joists by using 2 tapping  
screws(ST4.2X20) (Please prepare the screws and  
put on Flex-Z FastTM bracket before Flex-Z FastTM  
bracket is installed on joist). (Fig.2)  
3. Adjust the length of Flex-Z FastTM bracket as the  
spacing between joists, and install to joists by  
using 2 tapping screws (ST4.2X20). (Fig.3)  
4. Remove junction box cover and secure conduit  
or stress relief to junction box knock-out hole.  
(Fig.4)  
2 Tapping screws  
(ST4.2X20)  
Fig.3  
Circular duct  
Mastic or  
approved  
foil tape  
Conduit  
5. Install a circular duct and secure it with clamps,  
or ties and seal it with mastic or approved foil tape.  
4 inch 6 inch circular duct is needed to connect to  
relevant part of common adaptor. (Fig.4)  
6. Install the adaptor to Flex-Z FastTM bracket by  
using 2 self-drilling screws. (Fig.4)  
Knock-out  
hole  
Junction box  
cover  
2 Self-drilling screws  
Fig.4  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION (NEW CONSTRUCTION) CONTINUED  
7. Refer to wiring diagram on page 5.  
Follow all the local electrical safety codes as well  
as the National Electrical Code (NEC).  
Using UL approved wire nuts, connect house  
power wires to ventilating fan wires. (Fig.5)  
FV-05-11VKS1  
FV-05-11VK1  
FV-11-15VK1  
Conduit  
Earth ground  
to green  
Wire nut  
Junction  
box  
Netural to white  
CAUTION  
Two red wires  
(Connect to a general  
manual wall switch)  
Mount junction box cover carefully so that  
lead wires are not pinched.  
Live to black  
Fig.5  
8. Insert fan body and slide into adapter assy with  
some strength, untill the flange overlaps the  
Flex-Z FastTM bracket. Secure the fan body to  
Flex-Z FastTM bracket by using 2 self-drilling screws,  
plug connector to receptacle and secure the fan  
body to adaptor by using machine screw (M4X6).  
(Fig.6)  
Joist  
CAUTION  
Plug connector  
Receptacle  
Secure machine screw (M4X6) to the suitable  
hole and not touch the Flex-Z FastTM bracket.  
Please fix the screw carefully to avoid screw  
slip teeth.  
Machine  
screw  
(M4X6)  
2 Self-drilling  
screws  
9. Finish ceiling work. Ceiling hole should be aligned  
with the inside edge of the flange. (Fig.7)  
Fig.6  
10. Remove the tapes from louver and springs  
before installation. (Fig.8)  
Ceiling  
Unit: inches (mm)  
(270)  
10 1/2  
10 1/2  
IMPORTANT:  
(270)  
Replace the sensor cover before the installation  
(only for plug-in Motion sensor modular FV-MSVK1).  
As shown below:  
Keep on pressing the clasps when removing the ornamental cover.  
Gloves  
After finishing the ceiling job, fill gap between flange  
and ceillng with caulk or other sealant to prevent air  
leakage  
Fig.7  
Tapes  
Ornamental  
cover  
Insert the sensor cover (attachment for FV-MSVK1) into slot.  
Sensor  
cover  
Fig.8  
Clasp  
Ceiling  
11. Insert the grille mounting spring on the wiring  
side into the slot. (Fig.9)  
12. Plug in the specified devices as your choice  
(refer to installation on page 8). Insert the  
motion sensor (FV-MSVK1 only) or LED night  
light (FV-NLVK1 only) into slot of the grille.  
Fix the lead wire into the clasp (Fig.9).  
Motion sensor  
(FV-MSVK1 only)  
LED night light  
(FV-NLVK1 only)  
Fig.9  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION (NEW CONSTRUCTION) CONTINUED  
13. Adjust Pick-A-Flow switch; if used, adjust the  
FV-VS15VK1 Multi-Speed module. (Fig.10)  
Refer to indication on page 6.  
Ceiling  
Grille  
14. Insert the other mounting spring into the slot as  
shown and mount grille to fan body. (Fig.11)  
Fig.10  
CAUTION  
Mount grille carefully so that lead wire is  
Ceiling  
not pinched.  
Mounting  
spring  
Gloves  
Fig.11  
Grille  
INSTALLATION (RETROFIT)  
Unit: inches (mm)  
Joist  
Conduit  
Circular duct  
WARNING  
Disconnect power source before working  
on unit.  
4 Tapping  
screws (ST4.2x20)  
1. Remove the existing fan and cut ceiling openning.  
Secure the Flex-Z FastTM bracket to joists by using 4  
tapping screws (ST4.2x20) (Please prepare the  
screws and put on Flex-Z FastTM bracket before  
Flex-Z FastTM bracket is installed on joist).  
(275)  
10 7/8  
Fig.12  
Ceiling (already existed)  
Conduit  
Existing ductwork and wiring left in place. (Fig.12)  
Circular duct  
Mastic or  
approved  
foil tape  
2. Follow the step 1, 4, 5 on page 8 and step 7 on  
page 9. (Before connect the circular duct to the  
adaptor, should pull down the circular duct from  
the ceiling)  
Joist  
Knock-out  
hole  
3. Install the adaptor to Flex-Z FastTM bracket by  
using 2 self-drilling screws. (Fig.13)  
Junction box  
cover  
2 Self-drilling screws  
Ceiling  
Fig.13  
4. Secure the fan body to Flex-Z FastTM bracket by  
using 2 self-drilling screws, plug connector to  
receptacle and secure the fan body to adaptor  
by using machine screw (M4X6). (Fig.14)  
Joist  
CAUTION  
Secure machine screw (M4X6) to the suitable  
hole and not touch the Flex-Z FastTM bracket.  
Please fix the screw carefully to avoid screw  
slip teeth.  
Ceiling  
Flange  
Machine screw (M4X6)  
2 Self-drilling screws (Fix the  
flange and Flex-Z Fast bracket through the ceiling)  
TM  
5. Follow the step 10 to 14 on page 9 to 10.  
Fig.14  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mounting spring  
Gloves  
WARNING  
Disconnect power source before working  
on unit.  
Grille  
Slot  
Fig.15  
CAUTION  
Routine maintenance must be done  
every year. Please wear gloves during  
the cleaning work.  
Clasp  
Ceiling  
Never use gasoline, benzene, thinner or  
any other such chemicals for cleaning the  
ventilating fan.  
Motion sensor  
(FV-MSVK1 only)  
LED night light  
Do not immerse motor in water when  
cleaning. Do not soak resin parts in water  
over 140°F (60°C).  
(FV-NLVK1 only)  
Fig.16  
1. Remove grille by pulling down one mounting  
spring (Fig.15), then pull down the other. (For  
models plug-in FV-MSVK1 or FV-NLVK1: Pull  
down the mounting spring that without lead  
wire passed side, and remove motion sensor or  
LED night light as shown in Fig.16) (Squeeze  
mounting spring and pull down carefully)  
Gloves  
Fig.17  
2. Clean grille. (Don’t put into hot water. Use  
non-abrasive kitchen detergent, wipe dry with  
clean cloth) (Fig.17)  
Ceiling  
3. The grille should be dry after cleaning.  
Vacuum  
cleaner  
4. Remove dust and dirt from fan body using a  
vacuum cleaner. (Fig.18)  
Fig.18  
5. Using a cloth dampened with kitchen detergent,  
remove any dirt from fan body. Wipe dry with  
clean cloth. (Fig.19)  
Ceiling  
6. Reinstall grille.  
Gloves  
Fig.19  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRACTICAL GUIDE TO INSTALLATION  
Properly insulate the area around the fan to  
minimize building heat loss and gain. (Fig.20)  
Loose fill or batt insulation can be placed  
directly over the fan housing in the attic.  
Our fans and fan/light combination units do  
not create excessive heat that is a common  
problem with recessed light fixtures or some  
competitor’s fan/light combination. Our  
efficient, cool-running motors and our LED  
lighting unit do not create enough ambient  
heat to be subjected to these limitations.  
4 inches or 6 inches roof jack, wall cap,  
or soffit vent with backdraft damper  
Mechanically connect duct to termination  
and seal with mastic or approved foil  
faced tape  
2-3 ft straight run before elbow  
ln attic installation,  
caulk box to drywall  
Short piece of flexible duct helps  
alignment and absorbs sound.  
lnsulation  
Clamps plus mastic or approved  
foil faced tape at all flex joints  
Foil tape tightly covers all metal  
duct joints (glue PVC joints)  
Fig.20  
SPECIFICATIONS  
Specifications for Base Model fans  
Duct  
Air volume  
Noise  
Air  
direction  
Voltage Frequency  
Speed  
(rpm)  
Power  
(W)  
Weight  
Ib.  
diameter at 0.1"WG  
(inches)  
Model No.  
(V)  
(Hz)  
(sones)  
(CFM)  
<0.3  
<0.3  
<0.3  
<0.3  
<0.3  
50  
80  
110  
110  
130  
150  
740  
795  
915  
620  
630  
660  
3.5  
5.5  
9.5  
7.0  
10.0  
FV-05-11VKS1  
FV-05-11VK1  
Exhaust  
Exhaust  
4 or 6  
10.6(4.8)  
10.6(4.8)  
FV-11-15VK1  
13.0  
<0.3  
HVI Certified performance based on HVI Procedures 915, 916, and 920.  
Specifications for Multi Speed fans  
Duct  
Air volume  
Air  
direction  
Voltage Frequency  
(V) (Hz)  
Noise  
(sones)  
Speed  
(rpm)  
Power  
(W)  
Weight  
Ib.  
diameter at 0.1"WG  
(inches)  
Model No.  
(CFM)  
100  
90  
80  
70  
60  
50  
40  
30  
0
120  
110  
100  
90  
80  
70  
<0.3  
<0.3  
<0.3  
<0.3  
<0.3  
<0.3  
<0.3  
<0.3  
8.0  
6.5  
5.5  
4.3  
3.6  
3.5  
2.7  
2.4  
870  
835  
795  
760  
745  
740  
FV-05-11VKS1,  
FV-05-11VK1  
(Plug-in  
FV-VS15VK1)  
Exhaust  
Exhaust  
10.6(4.8)  
10.6(4.8)  
730  
725  
<0.3  
<0.3  
<0.3  
<0.3  
<0.3  
<0.3  
<0.3  
<0.3  
7.4  
7.0  
5.6  
4.9  
4.4  
3.8  
3.6  
3.1  
625  
620  
615  
610  
605  
600  
FV-11-15VK1  
(Plug-in  
FV-VS15VK1)  
60  
50  
595  
590  
0
Warning Concerning Removal of Covers. The unit should be serviced by qualified technicians only.  
Your product is designed and manufactured to ensure a minimum of maintenance. Should your unit  
require service or parts, call Panasonic Call Center at 1-866-292-7299 (USA) or 1-800-669-5165 (Canada).  
Two Riverfront Plaza, Newark, NJ 07102  
Panasonic corporation 2014  
X0114-2024 15VK10420B  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Washer 04 610 490 User Manual
NETGEAR Modem XM128S User Manual
Nikon Camera Lens 180mm F 28 User Manual
NXP Semiconductors Switch PIP3210 R User Manual
Olympus Microcassette Recorder DP 201 User Manual
Oregon Scientific Thermometer RGR126 User Manual
P3 International Pest Control Equipment P7906 User Manual
Panasonic Air Compressor DC66C10RCU6 User Manual
Panasonic Answering Machine KX TG5831AL User Manual
Panasonic Ventilation Hood FV 08vsl2 User Manual