92 sq.×25t
AC Fan Motor
(ASEN9)
DIMENSIONS (mm inch)
300 min
11.811 min
Earth tap M4
(200V class)
82.5 0.3
3.248 .012
92.5
3.642
3.5
.138
3.5
.138
3.5
.138
3.5
.138
82.5 0.3
3.248 .012
92.5
+1
+1
25
25
–0.3
–0.3
+.039
+.039
.984
.984
–.012
–.012
3.642
RoHS Directive compatibility information
Airflow
Airflow
Lead wire type
2 terminals type
RATING
1. Lead wire type, Standard speed
Ratedvoltage
(V)
Frequency
(Hz)
Input power,
Rated current*1 Locked current*3
Rotation
Max. air flow*2
Max. static
Noise*3
(dB(A))
Operating voltage Weight
Part number
+10
% (W)
(mA)
190/150
170/130
100/80
90/70
(mA)
speed*2 (r/min)
(m3/min)
pressure*2 (Pa)
range (V) (%)
(kg)
−20
ASEN90211
ASEN90212
ASEN90214
ASEN90216
100
115
200
230
200/170
180/160
110/100
100/80
34/39
(39/44)
50/60
13/10
2600/3100
0.80/0.98
43.1/60.8
10
0.3
2. 2 terminals type, Standard speed
Ratedvoltage
(V)
Frequency
(Hz)
Input power,
Rated current*1 Locked current*3
Rotation
Max. air flow*2
(m3/min)
Max. static
Noise*3
(dB(A))
Operating voltage Weight
Part number
+10
% (W)
(mA)
190/150
170/130
100/80
90/70
(mA)
speed*2 (r/min)
pressure*2 (Pa)
range (V) (%)
(kg)
−20
ASEN902519
ASEN902529
ASEN902549
ASEN902569
100
115
200
230
200/170
180/160
110/100
100/80
34/39
(39/44)
50/60
13/10
2600/3100
0.80/0.98
43.1/60.8
10
0.3
*1: Designates maximum values, *2: Designates minimum values, *3: Designates average values
Notes: 1. Values above without designations are averages.
2. Noise level was measured at a distance of 1 m from side of fan. Values in brackets were measured at a distance of 1 m from front of fan.
DATA (Airflow - Static pressure
MATERIALS USED
Characteristic Curve)
Frame: aluminum alloy die-casting
Propeller: plastic
Terminal: Equivalent to Faston #110
Label: 100 V class...black base
200 V class...red base
Bearings: ball bearings
Lead wires: UL3266 and AWG22
60 Hz
50 Hz
60
40
20
SPECIFICATIONS
Ambient temperature
Ambient humidity
Storage temperature
Breakdown voltage
Insulation resistance
Insulation class
–10°C to +60°C +14°F to +140°F
15 to 85%RH
–20°C to +70°C –4°F to +158°F
1,500 V AC for 1 min. (between charging section and frame)
Min. 100MΩ (at 500 V DC megger)(between charging section and frame)
UL:A class, CSA:B class
10 to 55Hz
Frequency
Double amplitude width
Applied direction
Applied time
0.75mm
Vibration
resistance
X, Y and Z directions
10 min. in each direction
Impedance protected
0
0.2
0.4
0.6
0.8
1.0
Airflow (m3/min)
Protection
Mean life
MTTF: 50,000 hrs. (Time it takes until rotation frequency drops 30% of initial value when
run continuously under 25°C 77°F and room humidity at the nominal voltage.)