Panasonic Switch AM1 NZ BASIC User Manual

AM1 (NZ BASIC)  
SWITCHES  
HIGH CONTACT CAPACITY,  
PRECISE OPERATION  
FEATURES  
TYPICAL APPLICATION  
• 10 A High current switching capacity  
and high precision  
• General industrial machinery  
• Medical equipment  
17.5  
49.2  
• Wide allowance of operating speed  
• Versatile variety of actuators  
• UL/C-UL approved  
• Measuring instruments  
• Transportation equipment  
• Home electric appliances  
24.1  
Compliance with RoHS Directive  
ORDERING INFORMATION  
Ex. AM  
1
5
0
1
K
F
Type of  
switch  
Basic  
specifications  
Upper body cover shape & terminal  
Actuators  
Contact  
NZ basic 1: Flat, solder terminal  
Upper body cover shape  
0: Standard type 0: Pin plunger  
F: Cadmium  
free  
(AM1)  
switch  
3: Flat, screw terminal  
5: Grooved, solder terminal  
7: Grooved, screw terminal  
1: Oil tight type  
3: Reversed  
action type  
1: Hinge lever (leaf spring)  
3: Hinge roller lever (roller, leaf, spring)  
4: Hinge short roller lever  
Flat  
Grooved  
4: One way type 5: Overtravel plunger  
6: Compact overtravel plunger  
7: Panel mount plunger  
811: Panel mount roller plunger  
812: Panel mount cross roller plunger  
Remarks: Not every combination is available. Please refer to the following table, “PRODUCT TYPES”.  
TERMINAL VARIATION  
Standard types, reversed action types and oil tight types are available in two terminal designs, solder and screw terminals, as shown  
in the above columns:  
Differences in dimension between solder and screw terminals are as follows;  
mm  
Solder terminal  
Screw terminal  
6.3  
9.1  
49.2  
49.2  
N.O.  
CIRCUT  
C
NO  
NC  
17.5  
17.5  
N.C.  
CIRCUT  
Terminal plate  
19.8  
M4 screw P0.7  
20.2  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AM1  
OPERATING CHARACTERISTICS  
Standard types  
Compact overtravel  
plunger  
Types of actuator  
Pin plunger  
Overtravel plunger  
Panel mount plunger  
Operating force, max.  
3.63 N  
1.12 N  
0.4  
Release force, min.  
Pretravel, max. mm  
Movement differential, max. mm  
Overtravel, min. mm  
0.05  
0.13  
1.5  
1.5  
5.6  
Operating position, mm  
15.9 0.4  
28.2 0.5  
21.2 0.5  
21.8 0.8  
Panel mount roller  
plunger  
Panel mount cross roller  
plunger  
Types of actuator  
Flexible leaf lever  
Flexible roller leaf lever  
Operating force, max.  
Release force, min.  
3.63 N  
1.47 N  
1.12 N  
0.4  
0.14 N  
4
Pretravel, max. mm  
Movement differential, max. mm  
Overtravel, min. mm  
0.05  
1.3  
3.6  
1.6  
Operating position, mm  
33.3 1.2  
17.5 0.8  
28.6 0.8  
Standard types (cont' d)  
Types of actuator  
Rigid lever  
0.69 N  
0.14 N  
10  
Rigid short roller lever  
Rigid roller lever  
Operating force, max.  
Release force, min.  
1.57 N  
0.42 N  
4.5  
0.98 N  
0.2 N  
7.5  
Pretravel, max. mm  
Movement differential, max. mm  
Overtravel, min. mm  
1.3  
0.7  
1.3  
5.6  
2.4  
3.6  
Operating position, mm  
19.1 0.7  
30.2 0.4  
30.2 0.7  
One way types  
Types of actuator  
Rigid short roller lever  
Rigid roller lever  
Operating force, max.  
Release force, min.  
2.23 N  
0.42 N  
3.5  
1.67 N  
0.42 N  
4.5  
Pretravel, max. mm  
Movement differential, max. mm  
Overtravel, min. mm  
Free position, max. mm  
Operating position, mm  
0.4  
0.5  
1.5  
2.4  
31.8  
43.3  
30.2 0.4  
41.3 0.4  
Reversed action types  
Types of actuator  
Rigid lever  
Rigid short roller lever  
Rigid roller lever  
Operating force, max.  
Release force, min.  
1.67 N  
0.27 N  
5.0  
5.30 N  
1.67 N  
2.5  
2.35 N  
0.56 N  
3.6  
Pretravel, max. mm  
Movement differential, max. mm  
Overtravel, min. mm  
0.9  
0.4  
0.7  
5.6  
2.0  
4.0  
Operating position, mm  
19.1 0.8  
30.2 0.5  
30.2 0.8  
Oil tight types  
Types of actuator  
Rigid lever  
0.69 N  
0.14 N  
10  
Rigid short roller lever  
Rigid roller lever  
0.98 N  
0.20 N  
7.5  
Operating force, max.  
Release force, min.  
Pretravel, max. mm  
Movement differential, max. mm  
Overtravel, min. mm  
Operating position, mm  
1.67 N  
0.42 N  
4.5  
1.5  
0.7  
1.3  
5.6  
2.4  
3.6  
19.1 0.7  
30.2 0.4  
30.2 0.7  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AM1  
mm General tolerance: 0.4  
DIMENSIONS  
1. Standard types  
Pin plunger  
Operating force,  
max.  
3.63 N  
1.12 N  
0.4  
23.3 0.3  
P. T.  
2.4  
Release force,  
min.  
O.P.  
14.6  
5.4  
15  
Pretravel,  
max. mm  
9.1  
Movement differential,  
max. mm  
0.05  
+0.1  
4.2  
dia. hole  
0.05  
+0.1  
4.2  
0.05  
17.5  
AM1100KF (Solder terminal)  
AM1300KF (Screw terminal)  
Overtravel,  
min. mm  
0.13  
4.5 0.1  
25.4 0.1  
49.2  
11.9  
Operating position,  
mm  
15.9 0.4  
Overtravel plunger  
Operating force,  
max.  
3.63 N  
1.12 N  
0.4  
23.3 0.3  
4 dia.  
6.35 dia.  
Release force,  
min.  
Plunger: Hardening steel  
P. T.  
Pretravel,  
max. mm  
8.4  
15  
O.P.  
Movement differential,  
max. mm  
0.05  
Overtravel,  
min. mm  
AM1105KF (Solder terminal)  
AM1305KF (Screw terminal)  
1.5  
Operating position,  
mm  
28.2 0.5  
Compact over plunger  
Operating force,  
max.  
3.63 N  
1.12 N  
0.4  
Plunger: Plastic  
P.T.  
Release force,  
min.  
0.3  
23.3  
0.4 max.  
7.1 dia.  
4.2  
Pretravel,  
max. mm  
O.P.  
+0.10  
–0.05  
0.5  
21.2  
4.2  
14.3 14.5  
Movement differential,  
max. mm  
0.05  
Overtravel,  
min. mm  
AM1106KF (Solder terminal)  
AM1306KF (Screw terminal)  
1.5  
+0.10  
4.2  
dia.  
–0.05  
Operating position,  
mm  
21.2 0.5  
Panel mount plunger  
Plunger: Plastic  
Operating force,  
max.  
R8  
M12 × P1  
3.63 N  
1.12 N  
0.4  
P.T.  
0.3  
23.3  
0.4 max.  
8.25 dia.  
Release force,  
min.  
Lock nut  
(2 thick)  
O.P.  
Pretravel,  
max. mm  
0.8  
21.8  
Nut (2 thick)  
13.1  
Movement differential,  
max. mm  
0.05  
0.5  
+0.10  
–0.05  
16  
4.2  
14.3  
Overtravel,  
min. mm  
5.6  
Operating position,  
mm  
AM1107KF (Solder terminal)  
AM1307KF (Screw terminal)  
+0.10  
–0.05  
4.2  
dia.  
21.8 0.8  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AM1  
Panel mount roller plunger  
mm General tolerance: 0.4  
Operating force,  
max.  
3.63 N  
1.12 N  
0.4  
Release force,  
min.  
P.T.  
Roller 12.7 dia. × 4.6  
: Plastic  
0.4 max.  
0.3  
23.3  
Pretravel,  
max. mm  
M12 × P1  
Movement differential,  
max. mm  
0.05  
O.P.  
Nut (2 thick)  
1.2  
33.3  
15.5  
Overtravel,  
min. mm  
3.6  
+0.10  
–0.05  
0.5  
4.2  
Operating position,  
mm  
16  
14.3  
AM110811KF (Solder terminal)  
AM130811KF (Screw terminal)  
33.3 1.2  
+0.10  
4.2  
dia.  
–0.05  
Panel mount cross roller plunger  
Operating force,  
max.  
3.63 N  
1.12 N  
0.4  
Release force,  
min.  
Roller 12.7 dia. × 4.6  
: Plastic  
P.T.  
0.3  
0.4 max.  
23.3  
Pretravel,  
max. mm  
M12 × P1  
Movement differential,  
max. mm  
0.05  
O.P.  
Nut (2 thick)  
1.2  
33.3  
Overtravel,  
min. mm  
15.5  
3.6  
+0.10  
–0.05  
Operating position,  
mm  
0.5  
4.2  
16  
33.3 1.2  
14.3  
AM110812KF (Solder terminal)  
AM130812KF (Screw terminal)  
+0.10  
4.2  
dia.  
–0.05  
Dimensions and Operating characteristics are the same as those of Panel mount roller plunger type. However, the roller joins the switch body at an angle of 90°.  
Flexible leaf lever  
Operating force,  
max.  
1.47 N  
Release force,  
min.  
0.14 N  
4
49.6 0.8  
Leaf: Stainless steel  
Pretravel,  
max. mm  
4.8  
Movement differential,  
max. mm  
F.P.  
O.P.  
14.6  
1.3  
Overtravel,  
min. mm  
AM1101KF (Solder terminal)  
AM1301KF (Screw terminal)  
1.6  
Operating position,  
mm  
17.5 0.8  
Flexible roller leaf lever  
Operating force,  
max.  
1.47 N  
0.14 N  
4
Roller 9.5 dia.×4:  
Release force,  
min.  
Plastic  
46 0.8  
Leaf: Stainless steel  
Pretravel,  
max. mm  
F.P.  
O.P.  
Movement differential,  
max. mm  
1.3  
14.6  
Overtravel,  
min. mm  
AM1103KF (Solder terminal)  
AM1303KF (Screw terminal)  
1.6  
Operating position,  
mm  
28.6 0.8  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AM1  
mm General tolerance: 0.4  
Rigid lever  
Operating force,  
max.  
0.69 N  
0.14 N  
10  
Lever: Stainless steel  
26.1  
Release force,  
min.  
R63.5  
4.8  
Pretravel,  
max. mm  
F.P.  
Movement differential,  
max. mm  
20.1 0.5  
O.P.  
1.3  
Overtravel,  
min. mm  
5.6  
AM1501KF (Solder terminal)  
AM1701KF (Screw terminal)  
Operating position,  
mm  
19.1 0.7  
Rigid short roller lever  
Operating force,  
max.  
1.57 N  
0.42 N  
4.5  
Roller 9.5 dia.×4:  
26.1  
Plastic  
Release force,  
min.  
Pretravel,  
max. mm  
R26.7  
Movement differential,  
max. mm  
F.P.  
O.P.  
0.7  
20.1 0.5  
Overtravel,  
min. mm  
2.4  
Operating position,  
mm  
AM1504KF (Solder terminal)  
AM1704KF (Screw terminal)  
30.2 0.4  
Rigid roller lever  
Operating force,  
max.  
0.98 N  
0.2 N  
7.5  
Roller 9.5 dia.×4:  
Release force,  
min.  
26.1  
Plastic  
R48.3  
Pretravel,  
max. mm  
Movement differential,  
max. mm  
F.P.  
1.3  
O.P.  
20.1 0.5  
Overtravel,  
min. mm  
3.6  
AM1503KF (Solder terminal)  
AM1703KF (Screw terminal)  
Operating position,  
mm  
30.2 0.7  
2. One way types  
This type is operated only to one direction, not to the reversed direction by the construction of the roller lever, pivoting away from the  
cam on the return stroke.  
Rigid short roller lever  
Operating force,  
max.  
2.23 N  
Roller 4.75 dia.×4.75:  
Plastic  
Release force,  
26.1  
0.42 N  
min.  
Pretravel,  
3.5  
R21.1  
max. mm  
Movement differential,  
0.4  
27.8 max.  
F.P.  
max. mm  
O.P.  
20.1 0.5  
Overtravel,  
min. mm  
1.5  
AM1544KF (Solder terminal)  
AM1744KF (Screw terminal)  
Operating position,  
mm  
30.2 0.4  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AM1  
Rigid roller lever  
mm General tolerance: 0.4  
Operating force,  
max.  
1.67 N  
0.42 N  
4.5  
Roller 9.5 dia.×4:  
Plastic  
26.1  
Release force,  
min.  
R31  
Pretravel,  
max. mm  
Movement differential,  
max. mm  
O.P. F.P.  
0.5  
34.1 max.  
20.1 0.5  
Overtravel,  
min. mm  
2.4  
Operating position,  
mm  
41.3 0.4  
AM1543KF (Solder terminal)  
AM1743KF (Screw terminal)  
3. Reversed action types  
When the actuator is operated, the switching mechanism returns to the free position. Extraordinary force by pushing the plunger too  
much is not put on the switching mechanism, which means stability in life.  
Rigid lever  
Lever: Stainless steel  
4.8  
18.7  
Operating force,  
max.  
1.67 N  
0.27 N  
5.0  
R56  
Release force,  
min.  
F.P.  
20.1 0.5  
9.1  
O.P.  
Pretravel,  
max. mm  
16.9 0.8  
Movement differential,  
max. mm  
0.9  
+0.1  
4.2  
dia. hole  
0.05  
+0.1  
4.2  
0.05  
Overtravel,  
min. mm  
4.5 0.1  
5.6  
17.5  
11.9  
25.4 0.1  
11.9  
AM1531KF (Solder terminal)  
AM1731KF (Screw terminal)  
Operating position,  
mm  
49.2  
19.1 0.8  
Rigid short roller lever  
Operating force,  
max.  
5.30 N  
1.67 N  
2.5  
Roller 9.5 dia.×4:  
Plastic  
Release force,  
min.  
18.7  
Pretravel,  
max. mm  
R19  
Movement differential,  
max. mm  
F.P.  
O.P.  
0.4  
20.1 0.5  
Overtravel,  
min. mm  
2.0  
AM1534KF (Solder terminal)  
AM1734KF (Screw terminal)  
Operating position,  
mm  
30.2 0.5  
Rigid roller lever  
Operating force,  
max.  
2.35 N  
0.56 N  
3.6  
Roller 9.5 dia.×4:  
Plastic  
Release force,  
min.  
18.7  
R41  
Pretravel,  
max. mm  
Movement differential,  
max. mm  
F.P.  
0.7  
O.P.  
20.1 0.5  
Overtravel,  
min. mm  
4.0  
Operating position,  
mm  
AM1533KF (Solder terminal)  
AM1733KF (Screw terminal)  
30.2 0.8  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AM1  
mm General tolerance: 0.4  
4. Oil tight types  
The pushbutton part is sealed with the rubber cap and the connected part between the cap and body is also coated with resin so that  
these parts are kept away from foreign matters. This type has resistance to oil.  
Rigid lever  
Operating force,  
0.69 N  
max.  
Plunger seal  
Lever: Stainless steel  
Release force,  
0.14 N  
min.  
26.1  
Pretravel,  
max. mm  
R63.5  
4.8  
10  
1.5  
Movement differential,  
max. mm  
F.P.  
20.1 0.5  
O.P.  
Overtravel,  
min. mm  
5.6  
Operating position,  
mm  
19.1 0.7  
AM1511KF (Solder terminal)  
AM1711KF (Screw terminal)  
Rigid short roller lever  
Operating force,  
max.  
1.67 N  
0.42 N  
4.5  
Plunger seal  
Roller 9.5 dia.×4:  
Release force,  
min.  
Plastic  
26.1  
Pretravel, max.  
mm  
R26.7  
Movement differential,  
max. mm  
F.P.  
O.P.  
0.7  
20.1 0.5  
16.9 0.8  
Overtravel,  
min. mm  
2.4  
AM1514KF (Solder terminal)  
AM1714KF (Screw terminal)  
Operating position,  
mm  
30.2 0.4  
Rigid roller lever  
Operating force,  
max.  
0.98 N  
0.20 N  
7.5  
Roller 9.5 dia.×4:  
Plunger seal  
Plastic  
Release force,  
min.  
26.1  
R48.3  
Pretravel,  
max. mm  
F.P.  
Movement differential,  
max. mm  
O.P.  
1.3  
20.1 0.5  
16.9 0.8  
Overtravel,  
min. mm  
3.6  
Operating position,  
mm  
AM1513KF (Solder terminal)  
AM1713KF (Screw terminal)  
30.2 0.7  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AM1  
NOTES  
1. Regarding fastening of switch body  
1) In fastening the switch body, use M4  
mounting screws to attach switches with  
the torque 1.5 N·m or less.  
3. Soldering operations  
Soldering should be done in less than 5  
seconds, with a 60 watt iron (tip  
temperature = 350°C max.). Care should  
be taken not to apply force to the terminal  
during soldering.  
2) After mounting and wiring, the  
insulation distance between ground and  
each terminal should be confirmed as  
sufficient.  
4. Avoid using switches in the  
following conditions:  
2. Adjustment of the operating device  
The operating device should be  
• In corrosive gases such as hydrogen  
sulfide.  
positioned so that it applies no stress to  
the pushbutton or actuator when the  
switch is in the open position. If this  
condition is exceeded, the mechanical  
and electrical performance will be  
impaired. In addition, the force applied by  
the operating device should be in a  
perpendicular direction. Even if the  
pushbutton is used in the full total travel  
position, there will be no influence on the  
life of the switch.  
• In flammable or explosive gases such  
as gasoline or thinner etc.  
• In a dusty environment.  
• In an ambient humidity over 85%.  
• In conditions where the perpendicular  
operating speed is less than 0.1 mm/sec.  
or more than 1,000 mm/sec.  
• In a silicon atmosphere.  
5. Others  
Caution should be taken not to drop  
switches.  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Ventilation Hood DA2210 User Manual
Moxa Technologies Network Card CP 168U User Manual
NewAir Dehumidifier AU 100 User Manual
Nikon Camcorder 1 J2 User Manual
Nikon Microscope Magnifier 50i and E100 User Manual
Omega Juicer L 4000 User Manual
OmniWare Scanner Pro 12 ScanSoft User Manual
Panasonic All in One Printer KXFLM600AL User Manual
Panasonic Laptop Docking Station JS950D5C020 User Manual
Paradyne Network Router 9123 User Manual