Panasonic Projector D10000 User Manual

Panasonic Projector RS-232C Control Specifications  
PT-DW10000/D10000  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Response (Callback) of the basic control command  
In the period when commands can be accepted  
Differs according to each command.  
In the period when commands cannot be accepted  
Hexadecimal  
Character  
02h  
45h  
E
52h  
R
34h  
4
30h  
0
31h  
1
03h  
03h  
In case of the parameter error  
Hexadecimal  
Character  
02h  
45h  
E
52h  
R
34h  
4
30h  
0
32h  
2
Notes when two or more projectors are used  
Make the communication conditions the same between output/input. IN and OUT can be independently  
set respectively. (When you set RS-422 OUT of the first projector to 38 400 bps, set RS-422 IN of the  
second projector to 38 400 bps.)  
Make only one in VPS SYSTEM MASTER and make all of the remainder VPS SYSTEM SLAVE.  
Set ID number different in each projector.  
I/O to RS-422 OUT is not done during MAIN POWER OFF. Turn on MAIN POWER of all projectors.  
Make only one of the each group in GROUP MASTER and make all the remainder-GROUP SLAVE.  
Attention:  
No command may be sent or received for 10 to 60 seconds after the lamp starts lighting. Try sending  
any command after that period has elapsed.  
When sending several commands, be sure to wait for a response from the projector, and send the next  
command after 0.5 seconds or more pass.  
It might take time by the time the response returns because the command is processed in the projector.  
Set the time-out to ten seconds or more.  
Notes:  
This projector will respond to the computer only in the following cases:  
If the sent ID coincides with the projector ID,  
VPS SYSTEM in RS232C settings of this projector is MASTER and the sent ID is ALL, or  
If-Group (A—Z) of the sent ID coincides with GROUP in RS232C settings of this projector and  
GROUP in RS232C settings of this projector is MASTER.  
When the command is received during STNDBY, this projector returns the receiving command as it is as  
a response (callback) if it is in the period when the concerned command cannot be accepted.  
Each setting/query command concerning P IN P controls to information on the user being set by current  
P IN P setting. Therefore, ER401 is returned as a response (callback) when P IN P setting is OFF.  
3/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Basic Control Command  
Explanatory notes  
Yes: Enable  
No: Disable  
2.1. Power ON (Lamp ON)  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
50h  
P
4Fh  
O
4Eh  
N
03h  
Response (Callback)  
In the period when the command can be accepted (This command in power-on condition is included)  
Hexadecimal  
Character  
02h  
50h  
P
4Fh  
O
4Eh  
N
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes Yes Yes Yes Yes (Yes)  
Notes:  
• When you confirm whether to have succeeded in power-on, confirm it by QPW (query power condition) command after  
receiving the callback of PON command.  
• When REMOTE2 is effective, ER401 is returned as a response (callback).  
2.2. Power OFF (Standby)  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
50h  
P
4Fh  
O
46h  
F
03h  
Response (Callback)  
In the period when the command can be accepted (This command in power-off condition is included)  
Hexadecimal  
Character  
02h  
50h  
P
4Fh  
O
46h  
F
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes Yes Yes Yes Yes (Yes)  
Notes:  
• When you confirm whether to have succeeded in power-off, confirm it by QPW (Query Power) command after receiving  
the callback of POF command.  
• When REMOTE2 is effective, ER401 is returned as a response (callback).  
2.3. AUTO SETUP  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
41h  
A
53h  
S
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Fh  
O
41h  
A
53h  
S
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No No No No Yes  
Note:  
• This command is acceptable only when RGB1 or RGB2 is selected and RGB PC signals are input. In other cases, ER401  
is returned.  
2.4. SHUTTER  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
53h  
S
48h  
H
3Ah  
:
*1  
*2  
03h  
Parameters (*1, *2)  
Shutter OFF  
Shutter ON  
Hexadecimal  
Character  
30h  
0
31h  
1
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Fh  
O
53h  
S
48h  
H
3Ah  
:
*1  
*2  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes No Yes Yes Yes (Yes)  
Note:  
• The setting by REMOTE2 is given to priority. When a command different from the setting of REMOTE2 is sent, ER402 is  
returned.  
4/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.5. Input Change  
Hexadecimal 02h  
Character  
41h  
A
44h 5Ah 5Ah 3Bh  
49h  
I
49h  
I
53h 3Ah  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
D
Z
Z
;
S
:
Parameters (*1, *2, *3, *4, *5, *6)  
RGB1  
RGB2  
47h  
G
Hexadecimal  
Character  
52h  
R
47h  
G
31h  
1
52h  
R
32h  
2
VIDEO  
49h  
I
S-VIDEO  
56h  
V
Hexadecimal  
Character  
56h  
V
44h  
D
53h  
S
44h  
D
DVI  
56h  
V
AUX  
55h  
U
Hexadecimal  
Character  
44h  
D
49h  
I
41h  
A
58h  
X
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
49h  
I
49h  
I
53h  
S
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes No Yes Yes Yes (Yes)  
Notes:  
• REMOTE2 is given to priority. Calls back ER402 if the input select of REMOTE2 is available.  
• When AUX is specified for the parameter with incompatible input module installed in the slot, ER401 is returned.  
• When AUX is specified for the parameter with no input module installed in the slot, ER402 is returned.  
2.6. TEST PATTERN  
Hexadecimal 02h  
Character  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
54h  
T
53h  
S
3Ah  
:
*1  
*2  
*3  
*4  
03h  
Parameters (*1, *2, *3, *4)  
OFF  
White  
31h  
Black  
Flag  
Reversed flag  
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
32h  
2
30h  
0
33h  
3
30h  
0
34h  
4
1
0
Window  
Reversed  
window  
Focus  
Color bar  
Gray 1 (20%  
brightness)  
Hexadecimal  
Character  
30h  
0
35h  
5
30h  
0
36h  
6
30h  
0
37h  
7
30h  
0
38h  
8
31h  
1
30h  
0
Ramp  
White  
Red  
Green  
Blue  
Hexadecimal  
Character  
31h  
1
31h  
1
32h  
2
31h  
1
32h  
2
32h  
2
32  
2
33  
3
32h  
2
34h  
4
10% brightness  
(White)  
5% brightness  
(White)  
Cyan  
Magenta  
Yellow  
Hexadecimal  
Character  
32h  
2
35h  
5
32h  
2
36h  
6
32h  
2
38h  
8
32h  
2
39h  
9
33h  
3
30h  
0
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Fh  
O
54h  
T
53h  
S
3Ah  
:
*1  
*2  
*3  
*4  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
2.7. ON SCREEN  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
4Fh  
O
53h  
S
3Ah  
:
*1  
*2  
03h  
Parameters (*1, *2)  
Shutter OFF  
Shutter ON  
Hexadecimal  
Character  
30h  
0
31h  
1
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Fh  
O
4Fh  
O
53h  
S
3Ah  
:
*1  
*2  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes No Yes Yes  
Note:  
• When the display setting of SECURITY is not OFF, ER401 is returned.  
5/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.8. MENU key  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
4Dh  
M
4Eh  
N
03h  
03h  
03h  
03h  
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
Acceptability  
02h  
4Fh  
O
4Dh  
M
4Eh  
03h  
N
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
No  
Yes  
Yes  
2.9. ENTER key  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
45h  
E
4Eh  
N
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
Acceptability  
02h  
4Fh  
O
45h  
E
4Eh  
03h  
N
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
No  
Yes  
Yes  
2.10. Up () key  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
43h  
C
55h  
U
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
Acceptability  
02h  
4Fh  
O
43h  
C
55h  
03h  
U
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
No  
Yes  
Yes  
2.11. Down () key  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
43h  
C
44h  
D
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
Acceptability  
02h  
4Fh  
O
43h  
C
44h  
03h  
D
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
No  
Yes  
Yes  
2.12. Left () key  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
43h  
C
4Ch  
L
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Fh  
O
43h  
C
4Ch  
L
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes No Yes No Yes Yes  
6/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.13. Right () key  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
43h  
C
52h  
R
03h  
03h  
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
Acceptability  
02h  
4Fh  
O
43h  
C
52h  
03h  
R
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
No  
Yes  
Yes  
2.14. DEFAULT key  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
53h  
S
54h  
T
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
Acceptability  
02h  
4Fh  
O
53h  
S
54h  
03h  
T
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No  
No  
No  
Yes  
Yes  
2.15. FUNC1 key  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
46h  
F
43h  
C
31h  
1
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
46h  
F
43h  
C
31h  
1
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No (Yes) (Yes) (Yes) (Yes)  
Note:  
• The acceptability conforms to the function allocated in FUNC1.  
2.16. SYSTEM SELECTOR  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
53h  
S
4Ch  
L
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Fh  
O
53h  
S
4Ch  
L
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No  
No  
Yes  
Yes  
Yes  
Yes  
Note:  
• When the input signal is not switchable, ER401 is returned.  
2.17. Numeric key  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
4Eh  
N
4Bh  
K
3Ah  
:
*1  
*2  
03h  
Parameters (*1, *2)  
0 key  
1 key  
31h  
1
2 key  
32h  
2
3 key  
33h  
3
4 key  
34h  
4
5 key  
35h  
5
6 key  
36h  
6
7 key  
37h  
7
8 key  
38h  
8
9 key  
39h  
9
Hexadecimal  
Character  
30h  
0
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Fh  
O
4Eh  
N
4Bh  
K
3Ah  
:
*1  
*2  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes No Yes Yes  
7/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.18. LAMP SELECT  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Ch  
L
50h  
P
4Dh  
M
3Ah  
:
*1  
*2  
*3  
*4  
03h  
Parameters (*1, *2, *3, *4)  
QUAD  
L1/L4  
L2/L3  
DUAL  
L1/L2/L3  
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
33h  
0
33h  
3
30h  
0
34h  
4
L1/L2/L4  
L1/L3/L4  
L2/L3/L4  
TRIPLE  
L1  
Hexadecimal  
Character  
30h  
0
35h  
5
30h  
0
36h  
6
30h  
0
37h  
7
30h  
0
38h  
8
30h  
0
39h  
9
L2  
L3  
L4  
SINGLE  
Hexadecimal  
Character  
31h  
1
30h  
0
31h  
1
31h  
1
31h  
1
32h  
2
31h  
1
33h  
3
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Ch  
L
50h  
P
4Dh  
M
3Ah  
:
*1  
*2  
*3  
*4  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
Note:  
• During the lamp change processing, ER401 is returned.  
2.19. INSTALLATION  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
49h  
I
4Ch  
L
3Ah  
:
*1  
*2  
03h  
Parameters (*1, *2)  
FRONT-F  
REAR-F  
FRONT-C  
REAR-C  
Hexadecimal  
Character  
30h  
0
31h  
1
32h  
2
33h  
3
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Fh  
O
49h  
I
4Ch  
L
3Ah  
:
*1  
*2  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
2.20. SUB MEMORY CHANGE  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
43h  
C
53h  
S
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
03h  
Parameters (*1, *2, *3, *4)  
*nn of submemory number (mm—nn)  
01  
02  
94  
03  
95  
04  
96  
Hexadecimal  
Character  
30h  
0
31h  
1
30h  
32h  
2
30h  
0
33h  
3
30h  
0
34h  
4
0
93  
Hexadecimal  
Character  
39h  
9
33h  
3
39h  
9
34h  
4
39h  
9
35h  
5
39h  
9
36h  
6
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Fh  
O
43h  
C
53h  
S
3Ah  
:
*1  
*2  
*3  
*4  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No No Yes Yes Yes  
8/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.21. SUB MEMORY CHANGE (Enhanced)  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
43h  
C
53h  
S
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
2Dh  
*5  
*6  
*7  
*8  
03h  
Parameters  
mm of submemory number (mm–nn) (*1,*2,*3,*4)  
01  
02  
03  
94  
04  
95  
Hexadecimal  
Character  
30h  
0
31h  
1
30h  
0
32h  
2
30h  
0
33h  
3
30h  
0
34h  
4
92  
93  
Hexadecimal  
Character  
39h  
9
32h  
2
39h  
9
33h  
3
39h  
9
34h  
4
39h  
9
35h  
5
nn of submemory number (mm–nn) (*5, *6, *7, *8)  
01  
02  
03  
95  
04  
96  
Hexadecimal  
Character  
30h  
0
31h  
1
30h  
0
32h  
2
30h  
0
33h  
3
30h  
0
34h  
4
93  
94  
Hexadecimal  
Character  
39h  
9
33h  
3
39h  
9
34h  
4
39h  
9
35h  
5
39h  
9
36h  
6
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Fh  
O
43h  
C
53h  
S
3Ah  
:
*1  
*2  
*3  
*4  
2Dh  
*5  
*6  
*7  
*8  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No  
No  
No  
Yes  
Yes  
Yes  
2.22. SUB MEMORY STORE  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
45h  
E
53h  
S
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Fh  
O
45h  
E
53h  
S
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No  
No  
No  
Yes  
Yes  
Yes  
2.23. SUB MEMORY DELETE  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
44h  
D
53h  
S
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
2Dh  
*5  
*6  
*7  
*8  
03h  
Parameters (*1, *2, *3, *4, *5, *6)  
mm of submemory number (mm–nn) (*1,*2)  
01  
02  
03  
94  
04  
95  
Hexadecimal  
Character  
30h  
0
31h  
1
30h  
0
32h  
2
30h  
0
33h  
3
30h  
0
34h  
4
92  
93  
Hexadecimal  
Character  
39h  
9
32h  
2
39h  
9
33h  
3
39h  
9
34h  
4
39h  
9
35h  
5
nn of submemory number (mm–nn) (*3,*4)  
01  
02  
03  
95  
04  
96  
Hexadecimal  
Character  
30h  
0
31h  
1
30h  
0
32h  
2
30h  
0
33h  
3
30h  
0
34h  
4
93  
94  
Hexadecimal  
Character  
39h  
9
33h  
3
39h  
9
34h  
4
39h  
9
35h  
5
39h  
9
36h  
6
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Fh  
O
44h  
D
53h  
S
3Ah  
:
*1  
*2  
*3  
*4  
2Dh  
*5  
*6  
*7  
*8  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
9/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.24. PICTURE MODE  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
56h  
V
50h  
P
4Dh  
M
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Parameters (*1, *2, *3, *4, *5, *6)  
DYNAMIC  
GRAPHIC  
USER  
Hexadecimal  
Character  
44h  
D
59h  
Y
STANDARD  
4Eh  
N
47h  
G
52h  
41h  
A
55h  
U
53h  
52h  
R
R
CINEMA  
49h  
S
NATURAL  
41h  
Hexadecimal  
Character  
53h  
S
54h  
T
44h  
D
43h  
C
4Eh  
N
4Eh  
N
54h  
T
I
A
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
50h  
P
4Dh  
M
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No  
No  
Yes  
Yes  
Yes  
Yes  
2.25. COLOR  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
56h  
V
43h  
C
4Fh  
O
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Parameters (*1, *2, *3, *4, *5, *6)  
0
1
30h  
0
2
30h  
0
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
98  
39h  
9
99  
39h  
9
100  
30h  
0
Hexadecimal  
Character  
30h  
0
38h  
8
30h  
0
39h  
9
31h  
1
30h  
0
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
43h  
C
4Fh  
O
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No No Yes Yes Yes  
Note:  
• It is displayed in the menu by the value in which 50 is subtracted from the specified value.  
2.26. TINT  
Hexadecimal  
02h  
41h  
A
*3  
44h  
D
*5  
5Ah  
Z
03h  
5Ah  
Z
3Bh  
;
56h  
V
54h  
T
4Eh  
N
3Ah  
:
Character  
Hexadecimal  
Character  
*1  
*2  
*4  
*6  
Parameters (*1, *2, *3, *4, *5, *6)  
0
1
30h  
0
61  
36h  
6
2
30h  
0
62  
36h  
6
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
60  
36h  
6
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
54h  
T
4Eh  
N
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No No Yes Yes Yes  
Note:  
• It is displayed in the menu by the value in which 31 is subtracted from the specified value.  
10/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.27. COLOR TEMP.  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
54h  
T
45h  
E
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
03h  
Parameters (*1, *2, *3, *4)  
LOW  
MIDDLE  
31h  
1
HIGH  
32h  
2
USER1  
34h  
4
USER2  
39h  
9
DEFAULT  
31h 30h  
Hexadecimal  
Character  
30h  
0
1
0
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Fh  
O
54h  
T
45h  
E
3Ah  
:
*1  
*2  
*3  
*4  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
Note:  
• If you specify parameters other than USER1 when COLOR MATCHING is not OFF, ER402 is returned.  
2.28. WHITE BALANCE LOW — R  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
56h  
V
4Fh  
O
52h  
R
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Parameters (*1, *2, *3, *4, *5, *6)  
1
2
30h  
0
3
30h  
0
Hexadecimal  
Character  
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
30h  
0
33h  
3
253  
35h  
5
254  
35h  
5
255  
35h  
5
Hexadecimal  
Character  
32h  
2
33h  
3
32h  
2
34h  
4
32h  
2
35h  
5
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
4Fh  
O
52h  
R
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
Notes:  
• When a parameter other than USER1 or USER2 is specified for COLOR TEMP., ER401 is returned.  
• It is displayed in the menu by the value in which 128 is subtracted from the specified value.  
2.29. WHITE BALANCE LOW — G  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
56h  
V
4Fh  
O
47h  
G
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Parameters(*1,*2,*3,*4,*5,*6)  
1
2
30h  
0
3
30h  
0
Hexadecimal  
Character  
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
30h  
0
33h  
3
253  
35h  
5
254  
35h  
5
255  
35h  
5
Hexadecimal  
Character  
32h  
2
33h  
3
32h  
2
34h  
4
32h  
2
35h  
5
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
4Fh  
O
47h  
G
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
Notes:  
•When a parameter other than USER1 or USER2 is specified for COLOR TEMP., ER401 is returned.  
• It is displayed in the menu by the value in which 128 is subtracted from the specified value.  
11/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.30. WHITE BALANCE LOW — B  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
56h  
V
4Fh  
O
42h  
B
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Parameters (*1, *2, *3, *4, *5, *6)  
1
2
30h  
0
3
30h  
0
Hexadecimal  
Character  
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
30h  
0
33h  
3
253  
35h  
5
254  
35h  
5
255  
35h  
5
Hexadecimal  
Character  
32h  
2
33h  
3
32h  
2
34h  
4
32h  
2
35h  
5
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
4Fh  
O
42h  
B
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
Notes:  
• When a parameter other than USER1 or USER2 is specified for COLOR TEMP., ER401 is returned.  
• It is displayed in the menu by the value in which 128 is subtracted from the specified value.  
2.31. WHITE BALANCE HIGH — R  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
56h  
V
48h  
H
52h  
R
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Parameters (*1, *2, *3, *4, *5, *6)  
0
1
30h  
0
2
30h  
0
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
253  
35h  
5
254  
35h  
5
255  
35h  
5
Hexadecimal  
Character  
32h  
2
33h  
3
32h  
2
34h  
4
32h  
2
35h  
5
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
48h  
H
52h  
R
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
Note:  
• When a parameter other than USER1 or USER2 is specified for COLOR TEMP., ER401 is returned.  
2.32. WHITE BALANCE HIGH — G  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
56h  
V
48h  
H
47h  
G
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Parameters (*1, *2, *3, *4, *5, *6)  
0
1
30h  
0
2
30h  
0
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
253  
35h  
5
254  
35h  
5
255  
35h  
5
Hexadecimal  
Character  
32h  
2
33h  
3
32h  
2
34h  
4
32h  
2
35h  
5
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
48h  
H
47h  
G
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
Note:  
• When a parameter other than USER1 or USER2 is specified for COLOR TEMP., ER401 is returned.  
12/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.33. WHITE BALANCE HIGH — B  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
56h  
V
48h  
H
42h  
B
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Parameters (*1, *2, *3, *4, *5, *6)  
0
1
30h  
0
2
30h  
0
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
253  
35h  
5
254  
35h  
5
255  
35h  
5
Hexadecimal  
Character  
32h  
2
33h  
3
32h  
2
34h  
4
32h  
2
35h  
5
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
48h  
H
42h  
B
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
Note:  
• When a parameter other than USER1 or USER2 is specified for COLOR TEMP., ER401 is returned.  
2.34. CONTRAST  
Hexadecimal  
02h  
41h  
A
*3  
44h  
D
*5  
5Ah  
Z
03h  
5Ah  
Z
3Bh  
;
56h  
V
43h  
C
4Eh  
N
3Ah  
:
Character  
Hexadecimal  
Character  
*1  
*2  
*4  
*6  
Parameters (*1, *2, *3, *4, *5, *6)  
1
2
30h  
0
62  
36h  
6
3
30h  
0
63  
36h  
6
Hexadecimal  
Character  
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
30h  
0
33h  
3
61  
36h  
6
Hexadecimal  
Character  
30h  
0
31h  
1
30h  
0
32h  
2
30h  
0
33h  
3
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
43h  
C
4Eh  
N
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No No Yes Yes Yes  
Note:  
• It is displayed in the menu by the value in which 32 is subtracted from the specified value.  
2.35. BRIGHTNESS  
Hexadecimal  
02h  
41h  
A
*3  
44h  
D
*5  
5Ah  
Z
03h  
5Ah  
Z
3Bh  
;
56h  
V
42h  
B
52h  
R
3Ah  
:
Character  
Hexadecimal  
Character  
*1  
*2  
*4  
*6  
Parameters (*1, *2, *3, *4, *5, *6)  
1
2
30h  
0
62  
36h  
6
3
30h  
0
63  
36h  
6
Hexadecimal  
Character  
30h  
0
30h  
0
31h  
1
30h  
0
31h  
2
30h  
0
33h  
3
61  
36h  
6
Hexadecimal  
Character  
30h  
0
30h  
1
30h  
0
31h  
2
30h  
0
32h  
3
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
42h  
B
52h  
R
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No No Yes Yes Yes  
Note:  
• It is displayed in the menu by the value in which 32 is subtracted from the specified value.  
13/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.36. SHARPNESS  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
56h  
V
53h  
S
52h  
R
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Parameters (*1, *2, *3, *4, *5, *6)  
0
1
30h  
0
14  
31h  
1
2
30h  
0
15  
31h  
1
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
13  
31h  
1
Hexadecimal  
Character  
30h  
0
33h  
3
30h  
0
34h  
4
30h  
0
35h  
5
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
53h  
S
52h  
R
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No  
No  
No  
Yes  
Yes  
Yes  
2.37. NOISE REDUCTION  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
56h  
V
4Eh  
N
53h  
S
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
03h  
Parameters (*1, *2)  
OFF  
30h  
0
ON or 1  
31h  
2
32h  
2
3
33h  
3
Hexadecimal  
Character  
1
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
4Eh  
N
53h  
S
3Ah  
:
*1  
*2  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No No Yes Yes Yes  
Notes:  
• When FRAME DELAY is set to SHORT, ER401 is returned.  
• During P IN P, ER401 is returned.  
14/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.38. DYNAMIC IRIS  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
41h  
A
49h  
I
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Parameters (*1, *2)  
Mode  
OFF  
1
2
3
USER  
AUTO  
IRIS  
41h  
A
MANUAL IRIS DYNAMIC-GAMMA  
Hexadecimal  
Character  
30h  
0
31h  
1
32h  
2
33h  
3
34h  
4
4Dh  
M
44h  
D
* When Mode is OFF—USER, parameters *3—*6 are not sent.  
Example: When you set USER into Mode  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
41h  
A
49h  
I
34h  
4
03h  
* When Mode is AUTO IRIS or DYNAMIC GAMMA, parameters *5 and *6 are not sent.  
Example: When Mode is AUTO IRIS and you set 3 into AUTO IRIS  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
41h  
A
49h  
I
3Ah  
:
Hexadecimal  
Character  
41h  
A
33h  
3
03h  
Example: When Mode is MANUAL IRIS and you set 30 into MANUAL IRIS  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
41h  
A
49h  
I
3Ah  
:
Hexadecimal  
Character  
4Dh  
M
33h  
3
30h  
0
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Fh  
O
41h  
A
49h  
I
3Ah  
:
*1  
*2  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No  
No  
Yes  
Yes  
Yes  
Yes  
2.39. DYNAMIC IRIS  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
41h  
A
49h  
I
3Ah  
:
*1  
*2  
03h  
Parameters (*1, *2)  
OFF  
30h  
0
1
31h  
1
2
32h  
2
3
33h  
3
USER  
34h  
4
Hexadecimal  
Character  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Fh  
O
41h  
A
49h  
I
3Ah  
:
*1  
*2  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No  
No  
Yes  
Yes  
Yes  
Yes  
2.40. DYNAMIC IRIS (AUTO IRIS)  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
41h  
A
49h  
I
3Ah  
:
Hexadecimal  
Character  
41h  
A
*1  
*2  
03h  
Parameters (*1, *2)  
OFF  
30h  
0
1
31h  
1
2
32h  
2
3
33h  
3
Hexadecimal  
Character  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Fh  
O
41h  
A
49h  
I
3Ah  
:
41h  
A
*1  
*2  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
15/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.41. DYNAMIC IRIS (MANUAL IRIS)  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
41h  
A
49h  
I
3Ah  
:
Hexadecimal  
Character  
4Dh  
M
*1  
*2  
*3  
*4  
03h  
Parameters (*1, *2, *3, *4)  
OFF  
1
2
3
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
30h  
0
33h  
3
60  
61  
62  
63  
Hexadecimal  
Character  
36h  
6
30h  
0
36h  
6
31h  
1
36h  
6
32h  
2
36h  
6
33h  
3
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Fh  
O
41h  
A
49h  
I
3Ah  
:
4Dh  
M
*1  
*2  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No  
No  
Yes  
Yes  
Yes  
Yes  
2.42. DYNAMIC IRIS (DYNAMIC GAMMA)  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
41h  
A
49h  
I
3Ah  
:
Hexadecimal  
Character  
44h  
D
*1  
*2  
03h  
Parameters (*1, *2)  
OFF  
30h  
0
1
31h  
1
2
32h  
2
3
33h  
3
Hexadecimal  
Character  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Fh  
O
41h  
A
49h  
I
3Ah  
:
44h  
D
*1  
*2  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No  
No  
Yes  
Yes  
Yes  
Yes  
2.43. TV-SYSTEM  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
56h  
V
53h  
S
47h  
G
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Parameters (*1, *2, *3, *4, *5, *6)  
AUTO 1  
AUTO 2  
54h  
T
PAL  
41h  
A
NTSC  
54h  
T
PAL-M  
41h  
A
Hexadecimal  
Character  
41h  
A
54h  
31h  
1
41h  
A
32h  
2
4Eh  
N
53h  
S
T
NTSC4.43  
34h  
Hexadecimal  
Character  
4Eh  
N
34h  
4
50h  
P
4Ch  
L
50h  
P
4Dh  
M
4
PAL-N  
41h  
A
SECAM  
45h  
E
PAL60  
36h  
6
Hexadecimal  
Character  
50h  
P
4Eh  
N
53h  
S
43h  
C
50h  
P
30h  
0
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
53h  
S
47h  
G
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
16/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.44. SHIFT H  
Hexadecimal  
02h  
41h  
A
*3  
44h  
D
*5  
5Ah  
Z
*7  
5Ah  
Z
03h  
3Bh  
;
56h  
V
54h  
T
48h  
H
3Ah  
:
Character  
Hexadecimal  
Character  
*1  
*2  
*4  
*6  
*8  
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)  
0
1
2
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
30h  
0
30h  
0
2
2
4093  
4094  
4095  
Hexadecimal  
Character  
34h  
4
30h  
0
39h  
9
33h  
3
34h  
4
30h  
0
39h  
9
34h  
4
34h  
4
30h  
0
39h  
9
35h  
5
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
54h  
T
48h  
H
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No No Yes No Yes  
Note:  
The maximum value that can be actually set changes according to the input signal and the input resolution setting, etc.  
2.45. SHIFT V  
Hexadecimal  
02h  
41h  
A
*3  
44h  
D
*5  
5Ah  
Z
03h  
5Ah  
Z
3Bh  
;
56h  
V
54h  
T
56h  
V
3Ah  
:
Character  
Hexadecimal  
Character  
*1  
*2  
*4  
*6  
Parameters (*1, *2, *3, *4, *5, *6)  
0
1
2
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
30h  
0
30h  
0
32h  
2
4093  
4094  
4095  
Hexadecimal  
Character  
34h  
4
30h  
0
39h  
9
33h  
3
34h  
4
30h  
0
39h  
9
34h  
4
34h  
4
30h  
0
39h  
9
35h  
5
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
54h  
T
56h  
V
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No No Yes No Yes  
Note:  
The maximum value that can be actually set changes according to the input signal and the input resolution setting, etc.  
17/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.46. ASPECT  
Hexadecimal  
02h  
41h  
A
*3  
44h  
D
03h  
5Ah  
Z
5Ah  
Z
3Bh  
;
56h  
V
53h  
S
45h  
E
3Ah  
:
Character  
Hexadecimal  
Character  
*1  
*2  
*4  
Parameters (*1, *2, *3, *4)  
• Input route: VIDEO  
Input signal: NTSC  
VID AUTO  
4:3 *1  
31h  
1
16:9 *2  
32h  
2
S4:3 *2  
33h  
3
THROUGH  
Hexadecimal  
Character  
30h  
0
35h  
5
HV FIT  
36h  
6
H FIT *1  
39h  
Hexadecimal  
Character  
9
• Input route: VIDEO  
Input signal: Except NTSC  
DEFAULT  
30h  
4:3 *1  
31h  
1
H FIT *1  
39h  
16:9 *2  
32h  
2
S4:3 *2  
33h  
3
THROUGH  
Hexadecimal  
Character  
35h  
5
0
HV FIT  
36h  
6
Hexadecimal  
Character  
9
• Input route: S-VIDEO  
Input signal: NTSC  
VID AUTO(PRI.)  
4:3 *1  
31h  
1
16:9 *2  
32h  
S4:3 *2  
33h  
THROUGH  
Hexadecimal  
Character  
30h  
0
35h  
5
2
3
HV FIT  
36h  
6
H FIT *1  
39h  
S1 AUTO  
VID AUTO  
Hexadecimal  
Character  
32h  
30h  
33h  
30h  
0
9
2
0
3
• Input route: S-VIDEO  
Input signal: Except NTSC  
DEFAULT  
30h  
0
HV FIT  
36h  
6
4:3 *1  
31h  
1
H FIT *1  
39h  
16:9 *2  
32h  
2
S4:3 *2  
33h  
3
THROUGH  
Hexadecimal  
Character  
35h  
5
Hexadecimal  
Character  
9
• Input route: Except VIDEO/S-VIDEO  
Input signal: SD  
DEFAULT  
16:9 *2  
32h  
S4:3 *2  
33h  
3
THROUGH  
Hexadecimal  
Character  
30h  
0
35h  
5
2
HV FIT  
36h  
6
H FIT *1  
39h  
Hexadecimal  
Character  
9
• Input route: Except VIDEO/S-VIDEO  
Input signal: HD  
DEFAULT  
4:3 *1  
31h  
1
S4:3 *2  
33h  
3
THROUGH  
Hexadecimal  
Character  
30h  
0
35h  
5
HV FIT  
36h  
6
H FIT *1  
39h  
Hexadecimal  
Character  
9
*1: Because it is not able to specify it in D10000, ER402 is returned.  
*2: Because it is not able to specify it in DW10000, ER402 is returned.  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
53h  
S
45h  
E
3Ah  
:
*1  
*2  
*3  
*4  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No No Yes No Yes  
Notes:  
• When it is not able to set it according to the input signal, ER402 is returned.  
• Parameter *3 and *4 are specified only for two digits.  
18/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.47. ZOOM H  
Hexadecimal  
02h  
41h  
A
*3  
44h  
D
*5  
5Ah  
Z
03h  
5Ah  
Z
3Bh  
;
4Fh  
O
5Ah  
Z
48h  
H
3Ah  
:
Character  
Hexadecimal  
Character  
*1  
*2  
*4  
*6  
Parameters (*1, *2, *3, *4, *5, *6)  
50  
51  
35h  
5
52  
35h  
5
Hexadecimal  
Character  
30h  
0
35h  
5
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
997  
39h  
9
998  
39h  
9
999  
39h  
9
Hexadecimal  
Character  
39h  
9
37h  
7
39h  
9
38h  
8
39h  
9
39h  
9
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Fh  
O
5Ah  
Z
48h  
H
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No No Yes No Yes  
Notes:  
• When ASPECT is THROUGH, ER401 is returned.  
• If INTERLOCKED is ON, set it to OFF.  
2.48. ZOOM V  
Hexadecimal 02h  
Character  
41h  
A
44h 5Ah 5Ah 3Bh 4Fh 5Ah 56h 3Ah  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
D
Z
Z
;
O
Z
V
:
Parameters (*1, *2, *3, *4, *5, *6)  
50  
51  
35h  
5
52  
35h  
5
Hexadecimal  
Character  
30h  
0
35h  
5
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
997  
39h  
9
998  
39h  
9
999  
39h  
9
Hexadecimal  
Character  
39h  
9
37h  
7
39h  
9
38h  
8
39h  
9
39h  
9
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Fh  
O
5Ah  
Z
56h  
V
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No No Yes No Yes  
Notes:  
• When ASPECT is THROUGH, ER401 is returned.  
• If INTERLOCKED is ON, set it to OFF.  
2.49. CLOCK PHASE  
Hexadecimal 02h  
Character  
41h  
A
44h 5Ah 5Ah 3Bh 56h  
43h 50h 3Ah  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
D
Z
Z
;
V
C
P
:
Parameters (*1, *2, *3, *4, *5, *6)  
0
1
30h  
0
2
30h  
0
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
29  
32h  
2
30  
33h  
3
31  
33h  
3
Hexadecimal  
Character  
30h  
0
39h  
9
30h  
0
30h  
0
30h  
0
31h  
1
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
43h  
C
50h  
P
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN  
No No No Yes No  
REMOTE2  
Yes  
Note:  
• It is able to accept only when the selected slot is RGB1 or RGB2, and ER401 is returned besides.  
19/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.50. INPUT RESOLUTION — TOTAL DOTS  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
56h  
V
54h  
T
44h  
D
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)  
330  
331  
Hexadecimal  
Character  
30h  
0
33h  
3
33h  
3
30h  
0
30h  
0
33h  
3
33h  
3
31h  
1
4093  
4094  
Hexadecimal  
Character  
34h  
4
30h  
0
39h  
9
33h  
3
34h  
4
30h  
0
39h  
9
34h  
4
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
54h  
T
44h  
D
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN  
No No No Yes Yes  
REMOTE2  
Yes  
Notes:  
• This command is acceptable only when RGB1 or RGB2 is selected and RGB signals are input. In other cases, ER401 is  
returned.  
The maximum value that can be actually set changes according to the input signal and the input resolution setting, etc.  
• When less than number of display dots is specified, ER402 is returned.  
2.51. INPUT RESOLUTION — DISPLAY DOTS  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
56h  
V
44h  
D
44h  
D
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)  
300  
301  
Hexadecimal  
Character  
30h  
0
33h  
3
30h  
0
30h  
0
30h  
0
33h  
3
30h  
0
31h  
1
2045  
2046  
Hexadecimal  
Character  
24h  
2
30h  
0
34h  
4
35h  
5
32h  
2
30h  
0
34h  
4
36h  
6
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
44h  
D
44h  
D
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN  
No No No Yes Yes  
REMOTE2  
Yes  
Notes:  
• This command is acceptable only when RGB1 or RGB2 is selected and RGB signals are input. In other cases, ER401 is  
returned.  
• When the value that exceeds the number of total dots is specified, ER402 is returned.  
20/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.52. INPUT RESOLUTION — TOTAL LINES  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
56h  
V
54h  
T
4Ch  
L
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)  
211  
212  
Hexadecimal  
Character  
30h  
0
32h  
2
31h  
1
31h  
1
30h  
0
32h  
2
31h  
1
32h  
2
2046  
2047  
Hexadecimal  
Character  
24h  
2
30h  
0
34h  
4
36h  
6
32h  
2
30h  
0
34h  
4
37h  
7
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
54h  
T
4Ch  
L
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN  
No No No Yes Yes  
REMOTE2  
Yes  
Notes:  
• This command is acceptable only when RGB1 or RGB2 is selected and RGB signals are input. In other cases, ER401 is  
returned.  
• When less than number of display lines is specified, ER402 is returned.  
2.53. INPUT RESOLUTION — DISPLAY LINES  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
56h  
V
44h  
D
4Ch  
L
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)  
200  
201  
Hexadecimal  
Character  
30h  
0
32h  
2
30h  
0
30h  
0
30h  
0
32h  
2
30h  
0
31h  
1
1199  
1200  
Hexadecimal  
Character  
21h  
1
31h  
1
39h  
9
39h  
9
31h  
1
32h  
2
30h  
0
30h  
0
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
44h  
D
4Ch  
L
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN  
No No No Yes Yes  
REMOTE2  
Yes  
Notes:  
• This command is acceptable only when RGB1 or RGB2 is selected and RGB signals are input. In other cases, ER401 is  
returned.  
• When the value that exceeds the number of total lines is specified, ER402 is returned.  
2.54. CLAMP POSITION  
Hexadecimal 02h  
Character  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
56h  
V
4Ch  
L
54h  
T
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Parameters(*1,*2,*3,*4,*5,*6)  
0
1
2
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
30h  
0
32h  
2
253  
35h  
5
254  
35h  
5
255  
35h  
5
Hexadecimal  
Character  
32h  
2
33h  
3
32h  
2
34h  
4
32h  
2
35h  
5
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
4Ch  
L
54h  
T
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN  
No No No Yes Yes  
REMOTE2  
Yes  
Note:  
• It is able to accept only when RGB1 or RGB2 is selected, and ER401 is returned besides.  
21/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.55. KEYSTONE  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
4Bh  
K
53h  
S
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)  
127  
126  
125  
31h  
1
Hexadecimal 2Dh  
Character  
31h  
1
32h  
2
37h  
7
2Dh  
31h  
1
32h  
36h  
6
2Dh  
32h  
2
35h  
5
2
+125  
+126  
+127  
Hexadecimal 2Bh  
Character  
31h  
1
32h  
2
35h  
5
2Bh  
+
31h  
1
32h  
2
36h  
6
2Bh  
+
31h  
1
32h  
2
37h  
7
+
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Fh  
O
4Bh  
K
53h  
S
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No  
No  
Yes  
Yes  
Yes  
Yes  
2.56. KEYSTONE2  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
53h  
S
4Bh  
K
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)  
127  
126  
125  
31h  
1
Hexadecimal 2Dh  
Character  
31h  
1
32h  
2
37h  
7
2Dh  
31h  
1
32h  
36h  
6
2Dh  
32h  
2
35h  
5
2
+125  
+126  
+127  
Hexadecimal 2Bh  
Character  
31h  
1
32h  
2
35h  
5
2Bh  
+
31h  
1
32h  
2
36h  
6
2Bh  
+
31h  
1
32h  
2
37h  
7
+
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Fh  
O
53h  
S
4Bh  
K
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
Notes:  
• When 0 is set into KEYSTONE, ER401 is returned.  
• Even if KEYSTONE2 value is changed, it might not operate according to KEYSTONE condition.  
2.57. LINEARITY  
Hexadecimal  
02h  
41h  
A
*3  
44h  
D
*5  
5Ah  
Z
*7  
5Ah  
Z
03h  
3Bh  
;
56h  
V
4Ch  
L
49h  
I
3Ah  
:
Character  
Hexadecimal  
Character  
*1  
*2  
*4  
*6  
*8  
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)  
127  
126  
125  
31h  
1
Hexadecimal 2Dh  
Character  
31h  
1
32h  
2
37h  
7
2Dh  
31h  
1
32h  
36h  
6
2Dh  
32h  
2
35h  
5
2
+125  
+126  
+127  
Hexadecimal 2Bh  
Character  
31h  
1
32h  
2
35h  
5
2Bh  
+
31h  
1
32h  
2
36h  
6
2Bh  
+
31h  
1
32h  
2
37h  
7
+
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
4Ch  
L
49h  
I
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
Notes:  
• When 0 is set into KEYSTONE, ER401 is returned.  
• Even if LINEARITY value is changed, it might not operate according to KEYSTONE condition.  
22/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.58. DISPLAY LANGUAGE  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
4Ch  
L
47h  
G
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Parameters (*1, *2, *3, *4, *5, *6)  
English  
German  
45h  
French  
52h  
Hexadecimal  
Character  
45h  
E
4Eh  
N
47h  
G
44h  
D
55h  
U
46h  
F
41h  
A
E
R
Spanish  
53h  
Italian  
54h  
T
Japanese  
50h  
Hexadecimal  
Character  
45h  
E
50h  
P
49h  
I
4Ch  
L
4Ah  
J
4Eh  
N
S
P
Chinese  
48h  
Russian  
55h  
Korean  
4Fh  
Hexadecimal  
Character  
43h  
C
49h  
I
52h  
R
53h  
S
4Bh  
K
52h  
R
H
U
O
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Fh  
O
4Ch  
L
47h  
G
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
2.59. BLANKING — UPPER  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
44h  
D
42h  
B
55h  
U
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Parameters (*1, *2, *3, *4, *5, *6)  
0
1
30h  
0
2
30h  
0
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
D10000  
523  
32h  
3
524  
32h  
3
525  
32h  
4
Hexadecimal  
Character  
35h  
5
33h  
8
35h  
5
34h  
9
35h  
5
35h  
0
DW10000  
538  
33h  
3
539  
33h  
3
540  
34h  
4
Hexadecimal  
Character  
35h  
5
38h  
8
35h  
5
39h  
9
35h  
5
30h  
0
Note:  
• The maximum value that can be set changes according to the setting condition of the input signal, ASPECT and ZOOM.  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
44h  
D
42h  
B
55h  
U
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
23/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.60. BLANKING — LOWER  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
44h  
D
42h  
B
42h  
B
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Parameters (*1, *2, *3, *4, *5, *6)  
0
1
30h  
0
2
30h  
0
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
D10000  
523  
32h  
3
524  
32h  
3
525  
32h  
4
Hexadecimal  
Character  
35h  
5
33h  
8
35h  
5
34h  
9
35h  
5
35h  
0
DW10000  
538  
33h  
3
539  
33h  
3
540  
34h  
4
Hexadecimal  
Character  
35h  
5
38h  
8
35h  
5
39h  
9
35h  
5
30h  
0
Note:  
• The maximum value that can be set changes according to the setting condition of the input signal, ASPECT and ZOOM.  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
44h  
D
42h  
B
42h  
B
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
2.61. BLANKING — RIGHT  
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 44h 42h 52h 3Ah  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Character  
A
D
Z
Z
;
D
B
R
:
Parameters (*1, *2, *3, *4, *5, *6)  
0
1
30h  
0
2
30h  
0
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
D10000  
698  
39h  
9
699  
39h  
9
700  
30h  
0
Hexadecimal  
Character  
36h  
6
38h  
8
36h  
6
39h  
9
37h  
7
30h  
0
DW10000  
958  
35h  
5
959  
35h  
5
960  
36h  
6
Hexadecimal  
Character  
39h  
9
38h  
8
39h  
9
39h  
9
39h  
9
30h  
0
Note:  
• The maximum value that can be set changes according to the setting condition of the input signal, ASPECT and ZOOM.  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
44h  
D
42h  
B
52h  
R
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
24/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.62. BLANKING — LEFT  
Hexadecimal 02h  
Character  
41h  
A
44h 5Ah 5Ah 3Bh  
44h  
D
42h 4Ch 3Ah  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
D
Z
Z
;
B
L
:
Parameters (*1, *2, *3, *4, *5, *6)  
0
1
30h  
0
2
30h  
0
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
D10000  
698  
39h  
9
699  
39h  
9
700  
30h  
0
Hexadecimal  
Character  
36h  
6
38h  
8
36h  
6
39h  
9
37h  
7
30h  
0
DW10000  
958  
35h  
5
959  
35h  
5
960  
36h  
6
Hexadecimal  
Character  
39h  
9
38h  
8
39h  
9
39h  
9
39h  
9
30h  
0
Note:  
• The maximum value that can be set changes according to the setting condition of the input signal, ASPECT and ZOOM.  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
44h  
D
42h  
B
4Ch  
L
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No  
No  
Yes  
Yes  
Yes  
Yes  
2.63. DVI EDID  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
44h  
O
42h  
E
4Ch  
D
3Ah  
:
*1  
*2  
03h  
Parameters (*1, *2)  
EDID1  
EDID2 (PC)  
Hexadecimal  
Character  
31h  
1
32h  
2
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
44h  
O
42h  
E
4Ch  
D
3Ah  
:
*1  
*2  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No  
No  
Yes  
Yes  
Yes  
Yes  
2.64. AUX DVI EDID  
Hexadecimal  
Character  
Hexadecimal  
Character  
02h  
41h  
44h  
D
55h  
U
5Ah  
Z
58h  
X
5Ah  
Z
03h  
3Bh  
;
44h  
O
42h  
E
4Ch  
D
3Ah  
:
A
41h  
A
*1  
*2  
Parameters (*1, *2)  
EDID1  
31h  
1
EDID2 (PC)  
Hexadecimal  
Character  
32h  
2
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
44h  
O
42h  
E
4Ch  
D
3Ah  
:
*1  
*2  
41h  
A
55h  
U
58h  
X
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
25/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.65. P IN P  
Hexadecimal  
02h  
41h  
A
03h  
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Fh  
O
50h  
P
50h  
P
3Ah  
:
Character  
Hexadecimal  
Character  
*1  
*2  
Parameters (*1, *2)  
OFF  
30h  
0
USER1  
31h  
1
USER2  
32h  
USER3  
33h  
Hexadecimal  
Character  
2
3
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Fh  
O
50h  
P
50h  
P
3Ah  
:
*1  
*2  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No  
No  
Yes  
Yes  
Yes  
Yes  
Note:  
• When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
2.66. P IN P — MAIN WINDOW  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Dh  
M
53h  
S
49h  
I
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Parameters (*1, *2)  
RGB1  
47h  
G
RGB2  
47h  
G
DVI  
56h  
V
Hexadecimal  
Character  
52h  
R
31h  
1
52h  
R
32h  
2
44h  
D
49h  
I
VIDEO  
49h  
I
S VIDEO  
56h  
AUX  
55h  
U
Hexadecimal  
Character  
56h  
V
44h  
D
53h  
S
44h  
D
41h  
A
58h  
X
V
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Dh  
M
53h  
S
49h  
I
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
Notes:  
• When AUX is specified for the parameter with incompatible input module installed in the slot, ER401 is returned.  
• When AUX is specified for the parameter with no input module installed in the slot, ER402 is returned.  
• When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
• If the same content as the channel set to sub window is specified ER402 is returned.  
• If RGB1 (RGB2) is specified when RGB2 (RGB1) is set for the sub window, ER402 is returned.  
• If S-VIDEO (VIDEO) is specified when VIDEO (S-VIDEO) is set for the sub window, ER402 is returned.  
2.67. P IN P — MAIN WINDOW:SIZE — INTERLOCKED  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Dh  
M
53h  
S
4Ch  
L
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
03h  
Parameters (*1, *2)  
OFF  
ON  
Hexadecimal  
Character  
30h  
0
31h  
1
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Dh  
M
53h  
S
4Ch  
L
3Ah  
:
*1  
*2  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
Note:  
• When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
26/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.68. P IN P — MAIN WINDOW:SIZE — V  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Dh  
M
53h  
S
56h  
V
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Parameters(*1, *2, *3, *4, *5, *6)  
10  
11  
97  
12  
98  
13  
99  
14  
Hexadecimal  
Character  
31h  
1
30h  
0
31h  
1
31h  
1
31h  
1
32h  
2
31h  
1
33h  
3
31h  
1
34h  
4
96  
100  
Hexadecimal  
Character  
39h  
9
36h  
6
39h  
9
37h  
7
39h  
9
38h  
8
39h  
9
39h  
9
31h 30h 30h  
1
0
0
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Dh  
M
53h  
S
56h  
V
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No  
No  
Yes  
Yes  
Yes  
Yes  
Note:  
• When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
2.69. P IN P — MAIN WINDOW:SIZE — H  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Dh  
M
53h  
S
48h  
H
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Parameters (*1, *2, *3, *4, *5, *6)  
10  
11  
97  
12  
98  
13  
99  
14  
Hexadecimal  
Character  
31h  
1
30h  
0
31h  
1
31h  
1
31h  
1
32h  
2
31h  
1
33h  
3
31h  
1
34h  
4
96  
100  
Hexadecimal  
Character  
39h  
9
36h  
6
39h  
9
37h  
7
39h  
9
38h  
8
39h  
9
39h  
9
31h 30h 30h  
1
0
0
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Dh  
M
53h  
S
48h  
H
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No  
No  
Yes  
Yes  
Yes  
Yes  
Note:  
• When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
2.70. P IN P — MAIN WINDOW:SIZE — HV  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Dh  
M
53h  
S
5Ah  
Z
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Parameters (*1, *2, *3, *4, *5, *6)  
10  
11  
97  
12  
98  
13  
99  
14  
Hexadecimal  
Character  
31h  
1
30h  
0
31h  
1
31h  
1
31h  
1
32h  
2
31h  
1
33h  
3
31h  
1
34h  
4
96  
100  
Hexadecimal  
Character  
39h  
9
36h  
6
39h  
9
37h  
7
39h  
9
38h  
8
39h  
9
39h  
9
31h 30h 30h  
1
0
0
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Dh  
M
53h  
S
5Ah  
Z
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
Note:  
• When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
27/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.71. P IN P — MAIN WINDOW:POSITION — V  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Dh  
M
50h  
P
56h  
V
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)  
D10000  
505  
504  
503  
35h  
5
Hexadecimal 2Dh  
Character  
35h  
5
30h  
0
+503  
35h  
5
2Dh  
35h  
5
30h  
34h  
4
2Dh  
30h  
0
33h  
3
0
+504  
+505  
Hexadecimal 2Bh  
Character  
DW10000  
35h  
5
30h  
0
33h  
3
2Bh  
+
35h  
5
30h  
0
34h  
4
2Bh  
+
35h  
5
30h  
0
35h  
3
+
520  
519  
518  
Hexadecimal 2Dh  
Character  
35h  
5
32h  
2
30h  
0
2Dh  
35h  
5
31h  
1
39h  
9
2Dh  
35h  
5
31h  
1
38h  
8
+518  
+519  
+520  
Hexadecimal 2Bh  
Character  
35h  
5
31h  
1
38h  
8
2Bh  
+
35h  
5
31h  
1
39h  
9
2Bh  
+
35h  
5
32h  
2
30h  
0
+
Note:  
• The maximum value and minimum value that can be actually set change according to the setting condition of the input  
signal, ASPECT and ZOOM.  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Dh  
M
50h  
P
56h  
V
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
Note:  
• When FRAME DELAY is set besides DEFAULT or RASTER POSITION is set besides 0, ER401 is returned.  
2.72. P IN P — MAIN WINDOW:POSITION — H  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
4Dh  
M
50h  
P
48h  
H
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)  
D10000  
674  
673  
672  
36h  
6
Hexadecimal 2Dh  
Character  
36h  
6
37h  
7
34h  
4
2Dh  
36h  
6
37h  
33h  
3
2Dh  
37h  
7
32h  
2
7
+672  
+673  
+674  
Hexadecimal 2Bh  
Character  
DW10000  
36h  
6
37h  
7
32h  
2
2Bh  
+
36h  
6
37h  
7
33h  
3
2Bh  
+
36h  
6
37h  
7
34h  
4
+
926  
925  
924  
Hexadecimal 2Dh  
Character  
39h  
9
32h  
2
36h  
6
2Dh  
39h  
9
32h  
2
35h  
5
2Dh  
39h  
9
32h  
2
34h  
4
+924  
+925  
+926  
Hexadecimal 2Bh  
Character  
39h  
9
32h  
2
34h  
4
2Bh  
+
39h  
9
32h  
2
35h  
5
2Bh  
+
39h  
9
32h  
2
36h  
6
+
Note:  
• The maximum value and minimum value that can be actually set change according to the setting condition of the input  
signal, ASPECT and ZOOM.  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Dh  
M
50h  
P
48h  
H
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
Note:  
• When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
28/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.73. P IN P — SUB WINDOW  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
53h  
S
49h  
I
53h  
S
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Parameters (*1, *2)  
RGB1  
47h  
G
RGB2  
47h  
G
DVI  
56h  
V
Hexadecimal  
Character  
52h  
R
31h  
1
52h  
R
32h  
2
44h  
D
49h  
I
VIDEO  
49h  
I
S VIDEO  
56h  
AUX  
55h  
U
Hexadecimal  
Character  
56h  
V
44hh  
D
53h  
S
44h  
D
41h  
A
58h  
X
V
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
53h  
S
49h  
I
53h  
S
3Ah  
:
*1  
*2  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
Note:  
• When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
• If the same content as the channel set to main window is specified ER402 is returned.  
• If RGB1 (RGB2) is specified when RGB2 (RGB1) is set for the main window, ER402 is returned.  
• If S-VIDEO (VIDEO) is specified when VIDEO (S-VIDEO) is set for the main window, ER402 is returned.  
2.74. P IN P — SUB WINDOW:SIZE — INTERLOCKED  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
53h  
S
53h  
S
4Ch  
L
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
03h  
Parameters (*1, *2)  
OFF  
ON  
Hexadecimal  
Character  
30h  
0
31h  
1
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
53h  
S
53h  
S
4Ch  
L
3Ah  
:
*1  
*2  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No  
No  
Yes  
Yes  
Yes  
Yes  
Note:  
• When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
2.75. P IN P — SUB WINDOW:SIZE — V  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
53h  
S
53h  
S
56h  
V
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Parameters (*1, *2, *3, *4, *5, *6)  
10  
11  
97  
12  
98  
13  
99  
14  
Hexadecimal  
Character  
31h  
1
30h  
0
31h  
1
31h  
1
31h  
1
32h  
2
31h  
1
33h  
3
31h  
1
34h  
4
96  
100  
Hexadecimal  
Character  
39h  
9
36h  
6
39h  
9
37h  
7
39h  
9
38h  
8
39h  
9
39h  
9
31h 30h 30h  
1
0
0
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
53h  
S
53h  
S
56h  
V
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
Note:  
• When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
29/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.76. P IN P — SUB WINDOW:SIZE — H  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
53h  
S
53h  
S
48h  
H
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Parameters (*1, *2, *3, *4, *5, *6)  
10  
11  
97  
12  
98  
13  
99  
14  
Hexadecimal  
Character  
31h  
1
30h  
0
31h  
1
31h  
1
31h  
1
32h  
2
31h  
1
33h  
3
31h  
1
34h  
4
96  
100  
Hexadecimal  
Character  
39h  
9
36h  
6
39h  
9
37h  
7
39h  
9
38h  
8
39h  
9
39h  
9
31h 30h 30h  
1
0
0
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
4Dh  
M
53h  
S
48h  
H
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No  
No  
Yes  
Yes  
Yes  
Yes  
Note:  
• When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
2.77. P IN P — SUB WINDOW:SIZE — HV  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
53h  
S
53h  
S
5Ah  
Z
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Parameters (*1, *2, *3, *4, *5, *6)  
10  
11  
97  
12  
98  
13  
99  
14  
Hexadecimal  
Character  
31h  
1
30h  
0
31h  
1
31h  
1
31h  
1
32h  
2
31h  
1
33h  
3
31h  
1
34h  
4
96  
100  
Hexadecimal  
Character  
39h  
9
36h  
6
39h  
9
37h  
7
39h  
9
38h  
8
39h  
9
39h  
9
31h 30h 30h  
1
0
0
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
53h  
S
53h  
S
5Ah  
Z
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
Note:  
• When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
30/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.78. P IN P — SUB WINDOW:POSITION — V  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
53h  
S
50h  
P
56h  
V
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)  
D10000  
505  
504  
503  
35h  
5
Hexadecimal 2Dh  
Character  
35h  
5
30h  
0
35h  
5
2Dh  
35h  
5
30h  
34h  
4
2Dh  
30h  
0
33h  
3
0
+503  
+504  
+505  
Hexadecimal 2Bh  
Character  
DW10000  
35h  
5
30h  
0
33h  
3
2Bh  
+
35h  
5
30h  
0
34h  
4
2Bh  
+
35h  
5
30h  
0
35h  
5
+
520  
519  
518  
Hexadecimal 2Dh  
Character  
35h  
5
32h  
2
30h  
0
2Dh  
35h  
5
31h  
1
39h  
9
2Dh  
35h  
5
31h  
1
38h  
8
+518  
+519  
+520  
Hexadecimal 2Bh  
Character  
35h  
5
31h  
1
38h  
8
2Bh  
+
35h  
5
31h  
1
39h  
9
2Bh  
+
35h  
5
32h  
2
30h  
0
+
Note:  
• The maximum value and minimum value that can be actually set change according to the setting condition of the input  
signal, ASPECT and ZOOM.  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
53h  
S
50h  
P
56h  
V
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No  
No  
Yes  
Yes  
Yes  
Yes  
Note:  
• When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
2.79. P IN P — SUB WINDOW:POSITION — H  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
53h  
S
50h  
P
48h  
H
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)  
D10000  
674  
673  
672  
36h  
6
Hexadecimal 2Dh  
Character  
36h  
6
37h  
7
34h  
4
2Dh  
36h  
6
37h  
33h  
3
2Dh  
37h  
7
32h  
2
7
+672  
+673  
+674  
Hexadecimal 2Bh  
Character  
DW10000  
36h  
6
37h  
7
32h  
2
2Bh  
+
36h  
6
37h  
7
33h  
3
2Bh  
+
36h  
6
37h  
7
34h  
4
+
926  
925  
924  
Hexadecimal 2Dh  
Character  
39h  
9
32h  
2
36h  
6
2Dh  
39h  
9
32h  
2
35h  
5
2Dh  
39h  
9
32h  
2
34h  
4
+924  
+925  
+926  
Hexadecimal 2Bh  
Character  
39h  
9
32h  
2
34h  
4
2Bh  
+
39h  
9
32h  
2
35h  
5
2Bh  
+
39h  
9
32h  
2
36h  
6
+
Note:  
• The maximum value and minimum value that can be actually set change according to the setting condition of the input  
signal, ASPECT and ZOOM.  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
53h  
S
50h  
P
48h  
H
3Ah  
:
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
Note:  
• When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
31/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.80. P IN P — FRAME LOCK  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
50h  
P
46h  
F
4Ch  
L
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
03h  
Parameters (*1, *2)  
MAIN WINDOW  
SUB WINDOW  
Hexadecimal  
Character  
30h  
0
31h  
1
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
50h  
P
46h  
F
4Ch  
L
3Ah  
:
*1  
*2  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No No Yes Yes Yes Yes  
Note:  
• When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
• When moving picture signals are input to either main or sub, the frame lock is fixed to the moving picture signals.  
2.81. P IN P — TYPE  
Hexadecimal 02h  
Character  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
50h  
P
54h  
T
50h  
P
3Ah  
:
*1  
*2  
03h  
Parameters (*1, *2)  
MAIN WINDOW  
SUB WINDOW  
Hexadecimal  
Character  
30h  
0
31h  
1
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
50h  
P
54h  
T
50h  
P
3Ah  
:
*1  
*2  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
No  
No  
Yes  
Yes  
Yes  
Yes  
Note:  
• When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
2.82. Set Date  
Hexadecimal  
02h  
*y1  
41h  
A
*y2  
44h  
D
*y3  
5Ah  
Z
*y4  
5Ah  
Z
*m1  
3Bh  
;
*m2  
54h  
T
*d1  
53h  
S
*D2  
44h  
D
*w  
3Ah  
:
03h  
Character  
Hexadecimal  
Character  
Parameters  
*y1—*y4: Year (4 digits)  
*m1, *m2: Month (2 digits)  
*d1, *d2: Day (2 digits)  
*w: Day of the week (Mon = 1, Tue = 2, Wed = 3, Thu = 4, Fri = 5, Sat = 6, Sun = 7)  
Set it by UTC (Coordinated Universal Time).  
Example: Thursday, June 29, 2006  
*y1  
32h  
2
*y2  
30h  
0
*y3  
30h  
0
*y4  
36h  
6
*m1  
30h  
0
*m2  
36h  
6
*d1  
32h  
2
*D2  
39h  
9
*w  
34h  
4
Hexadecimal  
Character  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
Hexadecimal  
Character  
02h  
54h  
T
*y4  
53h  
S
*m1  
44h  
D
*m2  
3Ah  
:
*d1  
*y1  
*d2  
*y2  
*w  
*y3  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes Yes Yes Yes Yes Yes  
32/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.83. Set Time  
Hexadecimal  
02h  
*h1  
41h  
A
*h2  
44h  
D
*m1  
5Ah  
Z
*m2  
5Ah  
Z
*s1  
3Bh  
;
*s2  
54h  
T
03h  
53h  
S
54h  
T
3Ah  
:
Character  
Hexadecimal  
Character  
Parameters  
*h1, *h2: Hour (2 digits)  
*m1, *m2Minute (2 digits)  
*s1, *s2Second (2 digits)  
Set it by UTC (Coordinated Universal Time).  
Example: 3 seconds at 3:45 p.m.  
*h1  
31h  
1
*h2  
35h  
5
*m1  
34h  
4
*m2  
35h  
5
*s1  
30h  
0
*s2  
33h  
3
Hexadecimal  
Character  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
54h  
T
53h  
S
54h  
T
3Ah  
:
Hexadecimal  
Character  
*h1  
*h2  
*m1  
*m2  
*s1  
*s2  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
2.84. Query Power  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
50h  
P
57h  
W
03h  
Response (Callback)  
OFF  
Hexadecimal  
Character  
ON  
Hexadecimal  
Character  
02h  
30h  
0
30h  
0
31h  
0
03h  
03h  
02h  
30h  
0
30h  
0
31h  
1
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
2.85. Query SHUTTER  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
53h  
S
48h  
H
03h  
Response (Callback)  
OFF  
Hexadecimal  
Character  
02h  
31h  
0
03h  
ON  
Hexadecimal  
Character  
02h  
31h  
1
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes No Yes Yes Yes Yes  
33/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.86. Query Input Change  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
03h  
I
N
Response (Callback)  
RGB1  
Hexadecimal  
Character  
RGB2  
Hexadecimal  
Character  
VIDEO  
Hexadecimal  
Character  
SVIDEO  
Hexadecimal  
Character  
DVI  
Hexadecimal  
Character  
AUX  
02h  
02h  
02h  
02h  
02h  
02h  
52h  
R
47h  
G
31h  
1
03h  
03h  
03h  
03h  
03h  
03h  
52h  
R
47h  
G
32h  
2
56h  
V
49h  
I
44h  
D
53h  
S
56h  
V
44h  
D
44h  
D
56h  
V
49h  
I
Hexadecimal  
Character  
Acceptability  
41h  
A
55h  
U
58h  
X
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
2.87. Query TEST PATTERN  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
54h  
T
53h  
S
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
03h  
Parameters (*1, *2, *3, *4)  
OFF  
White  
Black  
30h 32h  
Flag  
Reversed flag  
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
31h  
30h  
0
33h  
3
30h  
0
34h  
4
1
0
2
Window  
Reversed  
window  
Focus  
Colorbar  
Gray 1 (20%  
brightness)  
Hexadecimal  
Character  
30h  
0
35h  
5
30h  
0
36h  
6
30h  
0
37h  
7
30h  
0
38h  
8
31h  
1
30h  
0
Ramp  
White  
Red  
Green  
Blue  
Hexadecimal  
Character  
31h  
1
31h  
1
32h  
2
31h  
1
32h  
2
32h  
2
32  
2
33  
3
32h  
2
34h  
4
10% brightness  
(White)  
5% brightness  
(White)  
Cyan  
Magenta  
Yellow  
Hexadecimal  
Character  
32h  
2
35h  
5
32h  
2
36h  
6
32h  
2
38h  
8
32h  
2
39h  
9
33h  
3
30h  
0
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
2.88. Query ON SCREEN  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
4Fh  
O
53h  
S
03h  
Response (Callback)  
OFF  
Hexadecimal  
Character  
02h  
31h  
03h  
ON  
Hexadecimal  
Character  
02h  
31h  
1
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes No Yes Yes Yes Yes  
34/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.89. Query PICTURE MODE  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
50h  
P
4Dh  
M
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters(*1,*2,*3,*4,*5,*6)  
DYNAMIC  
GRAPHIC  
USER  
Hexadecimal  
Character  
44h  
D
59h  
Y
STANDARD  
4Eh  
N
47h  
G
52h  
41h  
A
52h  
U
41h  
41h  
R
R
CINEMA  
49h  
S
NATURAL  
41h  
Hexadecimal  
Character  
53h  
S
54h  
T
44h  
D
43h  
C
4Eh  
N
4Eh  
N
54h  
T
I
A
2.90. Query COLOR  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
56h  
V
43h  
C
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6)  
0
1
30h  
0
2
30h  
0
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
98  
39h  
9
99  
39h  
9
100  
30h  
0
Hexadecimal  
Character  
30h  
0
38h  
8
30h  
0
39h  
9
31h  
1
30h  
0
Note:  
• The value in which 50 is added to the value displayed in the menu is returned as a response (callback).  
2.91. Query TINT  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
56h  
V
54h  
T
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6)  
0
1
30h  
0
61  
36h  
6
2
30h  
0
62  
36h  
6
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
60  
36h  
6
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
Note:  
• The value in which 31 is added to the value displayed in the menu is returned as a response (callback).  
35/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.92. Query COLOR TEMP.  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
54h  
T
45h  
E
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4)  
LOW  
MIDDLE  
31h  
1
HIGH  
32h  
2
USER1  
34h  
4
USER2  
39h  
9
DEFAULT  
31h 30h  
Hexadecimal  
Character  
30h  
0
1
0
Note:  
• The response (callback) other than DEFAULT (10) is one digit.  
2.93. Query WHITE BALANCE LOW — R  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
4Fh  
O
52h  
R
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6)  
1
2
30h  
0
3
30h  
0
Hexadecimal  
Character  
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
30h  
0
33h  
3
253  
35h  
5
254  
35h  
5
255  
35h  
5
Hexadecimal  
Character  
32h  
2
33h  
3
32h  
2
34h  
4
32h  
2
35h  
5
Notes:  
• When a parameter other than USER1 or USER2 is specified for COLOR TEMP., ER401 is returned.  
• The value in which 128 is added to the value displayed in the menu is returned as a response (callback).  
2.94. Query WHITE BALANCE LOW — G  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
4Fh  
O
47h  
G
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6)  
1
2
30h  
0
3
30h  
0
Hexadecimal  
Character  
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
30h  
0
33h  
3
253  
35h  
5
254  
35h  
5
255  
35h  
5
Hexadecimal  
Character  
32h  
2
33h  
3
32h  
2
34h  
4
32h  
2
35h  
5
Notes:  
• When a parameter other than USER1 or USER2 is specified for COLOR TEMP., ER401 is returned.  
• The value in which 128 is added to the value displayed in the menu is returned as a response (callback).  
36/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.95. WHITE BALANCE LOW — B  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
4Fh  
O
42h  
B
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6)  
1
2
30h  
0
3
30h  
0
Hexadecimal  
Character  
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
30h  
0
33h  
3
253  
35h  
5
254  
35h  
5
255  
35h  
5
Hexadecimal  
Character  
32h  
2
33h  
3
32h  
2
34h  
4
32h  
2
35h  
5
Notes:  
• When a parameter other than USER1 or USER2 is specified for COLOR TEMP., ER401 is returned.  
• The value in which 128 is added to the value displayed in the menu is returned as a response (callback).  
2.96. Query WHITE BALANCE HIGH — R  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
48h  
H
52h  
R
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6)  
0
1
30h  
0
2
30h  
0
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
253  
35h  
5
254  
35h  
5
255  
35h  
5
Hexadecimal  
Character  
32h  
2
33h  
3
32h  
2
34h  
4
32h  
2
35h  
5
Note:  
• When a parameter other than USER1 or USER2 is specified for COLOR TEMP., ER401 is returned.  
2.97. Query WHITE BALANCE HIGH — G  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
48h  
H
47h  
G
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6)  
0
1
30h  
0
2
30h  
0
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
253  
35h  
5
254  
35h  
5
255  
35h  
5
Hexadecimal  
Character  
32h  
2
33h  
3
32h  
2
34h  
4
32h  
2
35h  
5
Note:  
• When a parameter other than USER1 or USER2 is specified for COLOR TEMP., ER401 is returned.  
37/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.98. Query WHITE BALANCE HIGH — B  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
48h  
H
42h  
B
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6)  
0
1
30h  
0
2
30h  
0
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
253  
35h  
5
254  
35h  
5
255  
35h  
5
Hexadecimal  
Character  
32h  
2
33h  
3
32h  
2
34h  
4
32h  
2
35h  
5
Note:  
• When a parameter other than USER1 or USER2 is specified for COLOR TEMP., ER401 is returned.  
2.99. Query CONTRAST  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
56h  
V
52h  
R
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6)  
1
2
30h  
0
62  
36h  
6
3
30h  
0
63  
36h  
6
Hexadecimal  
Character  
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
30h  
0
33h  
3
61  
36h  
6
Hexadecimal  
Character  
30h  
0
31h  
1
30h  
0
32h  
2
30h  
0
33h  
3
Note:  
• The value in which 32 is added to the value displayed in the menu is returned as a response (callback).  
2.100. Query BRIGHTNESS  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
56h  
V
42h  
B
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6)  
1
2
30h  
0
62  
36h  
6
3
30h  
0
63  
36h  
6
Hexadecimal  
Character  
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
30h  
0
33h  
3
61  
36h  
6
Hexadecimal  
Character  
30h  
0
31h  
1
30h  
0
32h  
2
30h  
0
33h  
3
Note:  
• The value in which 32 is added to the value displayed in the menu is returned as a response (callback).  
38/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.101. Query SHARPNESS  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
56h  
V
53h  
S
03h  
03h  
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
Acceptability  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6)  
0
30h  
0
13  
31h  
1
1
30h  
0
14  
31h  
1
2
30h  
0
15  
31h  
1
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
Hexadecimal  
Character  
30h  
0
33h  
3
30h  
0
34h  
4
30h  
0
35h  
5
2.102. Query NOISE REDUCTION  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
4Eh  
N
53h  
S
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters(*1,*2)  
OFF  
30h  
0
ON or 1  
31h  
2
32h  
2
3
33h  
3
Hexadecimal  
Character  
Notes:  
• When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
• During P IN P, ER401 is returned.  
1
2.103. Query DYNAMIC IRIS  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
41h  
A
49h  
I
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2)  
OFF  
30h  
0
1
31h  
1
2
32h  
2
3
33h  
3
USER  
34h  
4
Hexadecimal  
Character  
39/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.104. Query DYNAMIC IRIS  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
41h  
A
49h  
I
3Ah  
:
*1  
*2  
03h  
Parameters (*1, *2)  
AUTO IRIS  
MANUAL IRIS  
DYNAMIC-GAMMA  
Hexadecimal  
Character  
41h  
A
4Dh  
M
44h  
D
Response (Callback)  
In the period when the command can be accepted  
When AUTO IRIS or DYNAMIC-GAMMA is specified for the parameter (*1, *2)  
Hexadecimal  
Character  
02h  
*3  
*4  
03h  
When MANUAL IRIS is specified for the parameter (*1, *2)  
Hexadecimal  
Character  
02h  
*5  
*6  
*7  
*8  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters (*3, *4,)  
OFF  
30h  
0
1
31h  
1
2
32h  
2
3
33h  
3
Hexadecimal  
Character  
Parameters (*5, *6, *7, *8,)  
OFF  
1
2
3
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
30h  
0
33h  
3
60  
61  
62  
63  
Hexadecimal  
Character  
36h  
6
30h  
0
36h  
6
31h  
1
36h  
6
32h  
2
36h  
6
33h  
3
2.105. Query TV-SYSTEM  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
53h  
S
47h  
G
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6)  
AUTO 1  
AUTO 2  
54h  
T
PAL  
41h  
A
NTSC  
54h  
T
PAL-M  
41h  
A
Hexadecimal  
Character  
41h  
A
54h  
31h  
1
41h  
A
32h  
2
4Eh  
N
53h  
S
T
NTSC4.43  
34h  
Hexadecimal  
Character  
4Eh  
N
34h  
4
50h  
P
4Ch  
L
50h  
P
4Dh  
M
4
PAL-N  
41h  
A
SECAM  
45h  
E
PAL60  
36h  
6
Hexadecimal  
Character  
50h  
P
4Eh  
N
53h  
S
43h  
C
50h  
P
30h  
0
40/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.106. Query SHIFT H  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
54h  
T
48h  
H
3Ah  
:
Hexadecimal  
Character  
31h  
1
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes No No Yes No Yes  
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)  
0
1
2
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
30h  
0
30h  
0
2
2
4093  
4094  
4095  
Hexadecimal  
Character  
34h  
4
30h  
0
39h  
9
33h  
3
34h  
4
30h  
0
39h  
9
34h  
4
34h  
4
30h  
0
39h  
9
35h  
5
2.107. Query SHIFT V  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
54h  
T
56h  
V
3Ah  
:
Hexadecimal  
Character  
31h  
1
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
No  
Yes  
No  
Yes  
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)  
0
1
2
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
30h  
0
30h  
0
32h  
2
4093  
4094  
30h  
0
4095  
Hexadecimal  
Character  
34h  
4
30h  
0
39h  
9
33h  
3
34h  
4
39h  
9
34h  
4
34h  
4
30h  
0
39h  
9
35h  
5
41/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.108. Query ASPECT  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
53  
S
45h  
E
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
No  
Yes  
No  
Yes  
Parameters (*1, *2, *3, *4)  
• Input route: VIDEO  
Input signal: NTSC  
VID AUTO  
4:3 *1  
31h  
1
H FIT *1  
39h  
16:9 *2  
32h  
2
S4:3 *2  
33h  
3
THROUGH  
Hexadecimal  
Character  
30h  
0
35h  
5
HV FIT  
36h  
6
Hexadecimal  
Character  
9
• Input route: VIDEO  
Input signal: Except NTSC  
DEFAULT  
30h  
4:3 *1  
31h  
1
H FIT *1  
39h  
16:9 *2  
32h  
2
S4:3 *2  
33h  
3
THROUGH  
Hexadecimal  
Character  
35h  
5
0
HV FIT  
36h  
6
Hexadecimal  
Character  
9
• Input route: S-VIDEO  
Input signal: NTSC  
VID AUTO(PRI.)  
4:3 *1  
31h  
1
16:9 *2  
32h  
2
S4:3 *2  
33h  
3
THROUGH  
Hexadecimal  
Character  
30h  
0
35h  
5
HV FIT  
36h  
6
H FIT *1  
39h  
S1 AUTO *3  
VID AUTO *3  
Hexadecimal  
Character  
32h  
2
30h  
0
33h  
3
30h  
0
9
• Input route: S-VIDEO  
Input signal: Except NTSC  
DEFAULT  
30h  
0
HV FIT  
36h  
6
4:3 *1  
31h  
1
H FIT *1  
39h  
16:9 *2  
32h  
2
S4:3 *2  
33h  
3
THROUGH  
Hexadecimal  
Character  
35h  
5
Hexadecimal  
Character  
9
• Input route: Except VIDEO/S-VIDEO  
Input signal: SD  
DEFAULT  
16:9 *2  
32h  
S4:3 *2  
33h  
3
THROUGH  
Hexadecimal  
Character  
30h  
0
35h  
5
2
HV FIT  
36h  
6
H FIT *1  
39h  
Hexadecimal  
Character  
9
• Input route: Except VIDEO/S-VIDEO  
Input signal: HD  
DEFAULT  
4:3 *1  
31h  
1
S4:3 *2  
33h  
3
THROUGH  
Hexadecimal  
Character  
30h  
0
35h  
5
HV FIT  
36h  
6
H FIT *1  
39h  
Hexadecimal  
Character  
9
*1: Effective for DW10000 only  
*2: Effective for D10000 only  
*3: The response (callback) other than this item is one digit.  
42/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.109. Query ZOOM H  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
5Ah  
Z
48h  
H
03h  
03h  
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
Acceptability  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
No  
Yes  
No  
Yes  
Parameters (*1, *2, *3, *4, *5, *6)  
50  
35h  
5
997  
39h  
9
51  
35h  
5
998  
39h  
9
52  
35h  
5
999  
39h  
9
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
Hexadecimal  
Character  
Notes:  
• When ASPECT is THROUGH, ER401 is returned.  
• Even if INTERLOCKED is ON, the value of ZOOM H is returned.  
39h  
9
37h  
7
39h  
9
38h  
8
39h  
9
39h  
9
2.110. Query ZOOM V  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
5Ah  
Z
56h  
V
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
Acceptability  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
No  
Yes  
No  
Yes  
Parameters (*1, *2, *3, *4, *5, *6)  
50  
35h  
5
997  
39h  
9
51  
35h  
5
998  
39h  
9
52  
35h  
5
999  
39h  
9
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
Hexadecimal  
Character  
Notes:  
• When ASPECT is THROUGH, ER401 is returned.  
• Even if INTERLOCKED is ON, the value of ZOOM H is returned.  
39h  
9
37h  
7
39h  
9
38h  
8
39h  
9
39h  
9
2.111. Query CLOCK PHASE  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
43h  
C
50h  
P
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
No  
Yes  
No  
Yes  
Parameters (*1, *2, *3, *4, *5, *6)  
0
1
30h  
0
30  
33h  
3
2
30h  
0
31  
33h  
3
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
29  
32h  
2
Hexadecimal  
Character  
30h  
0
39h  
9
30h  
0
30h  
0
30h  
0
31h  
1
Note:  
• It is able to accept only when the selected slot is RGB1 or RGB2, and ER401 is returned besides.  
43/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.112. Query INPUT RESOLUTION — TOTAL DOTS  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
54h  
T
44h  
D
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
No  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)  
0
1
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
4093  
4094  
Hexadecimal  
Character  
34h  
4
30h  
0
39h  
9
33h  
3
34h  
4
30h  
0
39h  
9
34h  
4
Note:  
• This command is acceptable only when RGB1 or RGB2 is selected and RGB signals are input. In other cases, ER401 is  
returned.  
2.113. Query INPUT RESOLUTION — DISPLAY DOTS  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
44h  
D
44h  
D
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
No  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)  
300  
301  
Hexadecimal  
Character  
30h  
0
33h  
3
30h  
0
30h  
0
30h  
0
33h  
3
30h  
0
31h  
1
2045  
2046  
Hexadecimal  
Character  
32h  
2
30h  
0
34h  
4
35h  
5
32h  
2
30h  
0
34h  
4
36h  
6
Note:  
• This command is acceptable only when RGB1 or RGB2 is selected and RGB signals are input. In other cases, ER401 is  
returned.  
2.114. Query INPUT RESOLUTION — TOTAL LINES  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
54h  
T
4Ch  
L
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
No  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)  
211  
212  
Hexadecimal  
Character  
30h  
0
32h  
2
31h  
1
31h  
1
30h  
0
32h  
2
31h  
1
32h  
2
2046  
2047  
Hexadecimal  
Character  
32h  
2
30h  
0
34h  
4
36h  
6
32h  
2
30h  
0
34h  
4
37h  
7
Note:  
• This command is acceptable only when RGB1 or RGB2 is selected and RGB signals are input. In other cases, ER401 is  
returned.  
44/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.115. Query INPUT RESOLUTION — DISPLAY LINES  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
44h  
D
4Ch  
L
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN  
REMOTE2  
Yes  
Yes  
No  
No  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)  
200  
201  
Hexadecimal  
Character  
30h  
0
32h  
2
30h  
0
30h  
0
30h  
0
32h  
2
30h  
0
31h  
1
1199  
1200  
Hexadecimal  
Character  
31h  
1
31h  
1
39h  
9
39h  
8
31h  
1
32h  
2
30h  
0
30h  
0
Note:  
• This command is acceptable only when RGB1 or RGB2 is selected and RGB signals are input. In other cases, ER401 is  
returned.  
2.116. Query CLAMP POSITION  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
4Ch  
L
54h  
T
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN  
REMOTE2  
Yes  
Yes  
No  
No  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6)  
0
1
30h  
0
2
30h  
0
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
253  
35h  
5
254  
35h  
5
255  
35h  
5
Hexadecimal  
Character  
32h  
2
33h  
3
32h  
2
34h  
4
32h  
2
35h  
5
Note:  
• This command is acceptable only when RGB1 or RGB2 is selected. In other cases, ER401 is returned.  
2.117. Query KEYSTONE  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
4Bh  
K
53h  
S
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)  
127  
126  
125  
31h  
1
Hexadecimal 2Dh  
Character  
31h  
1
32h  
2
37h  
7
2Dh  
31h  
1
32h  
36h  
6
2Dh  
32h  
2
35h  
5
2
+125  
+126  
+127  
Hexadecimal 2Bh  
Character  
31h  
1
32h  
2
35h  
5
2Bh  
+
31h  
1
32h  
2
36h  
6
2Bh  
+
31h  
1
32h  
2
37h  
7
+
45/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.118. Query KEYSTONE2  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
53h  
S
4Bh  
K
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)  
127  
126  
125  
31h  
1
Hexadecimal 2Dh  
Character  
31h  
1
32h  
2
37h  
7
2Dh  
31h  
1
32h  
36h  
6
2Dh  
32h  
2
35h  
5
2
+125  
+126  
+127  
Hexadecimal 2Bh  
31h  
1
32h  
2
35h  
5
2Bh  
+
31h  
1
32h  
2
36h  
6
2Bh  
+
31h  
1
32h  
2
37h  
7
Character  
+
2.119. Query LINEARITY  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
4Ch  
L
49h  
I
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)  
127  
126  
125  
Hexadecimal 2Dh  
Character  
31h  
1
32h  
2
37h  
7
2Dh  
31h  
1
32h  
2
36h  
6
2Dh  
31h  
1
32h  
2
35h  
5
+125  
+126  
+127  
Hexadecimal 2Bh  
Character  
31h  
1
32h  
2
35h  
5
2Bh  
+
31h  
1
32h  
2
36h  
6
2Bh  
+
31h  
1
32h  
2
37h  
7
+
2.120. Query DISPLAY LANGUAGE  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
4Ch  
L
47h  
G
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6)  
English  
German  
45h  
French  
52h  
Hexadecimal  
Character  
45h  
E
4Eh  
N
47h  
G
44h  
D
55h  
U
46h  
F
41h  
A
E
R
Spanish  
53h  
Italian  
54h  
T
Japanese  
50h  
Hexadecimal  
Character  
45h  
E
50h  
P
49h  
I
4Ch  
L
4Ah  
J
4Eh  
N
S
P
Chinese  
48h  
Russian  
55h  
Korean  
4Fh  
Hexadecimal  
Character  
43h  
C
49h  
I
52h  
R
53h  
S
4Bh  
K
52h  
R
H
U
O
46/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.121. Query BLANKING — UPPER  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
4Ch  
L
55  
U
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN  
REMOTE2  
Yes  
Yes  
No  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6)  
0
1
30h  
0
2
30h  
0
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
D10000  
523  
32h  
3
524  
32h  
3
525  
32h  
4
Hexadecimal  
Character  
35h  
5
33h  
8
35h  
5
34h  
9
35h  
5
35h  
0
DW10000  
538  
33h  
3
539  
33h  
3
540  
34h  
4
Hexadecimal  
Character  
35h  
5
38h  
8
35h  
5
39h  
9
35h  
5
30h  
0
2.122. Query BLANKING — LOWER  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
4Ch  
L
42h  
B
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN  
REMOTE2  
Yes  
Yes  
No  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6)  
0
1
30h  
0
2
30h  
0
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
D10000  
523  
32h  
3
524  
32h  
3
525  
32h  
4
Hexadecimal  
Character  
35h  
5
33h  
8
35h  
5
34h  
9
35h  
5
35h  
0
DW10000  
538  
33h  
3
539  
33h  
3
540  
34h  
4
Hexadecimal  
Character  
35h  
5
38h  
8
35h  
5
39h  
9
35h  
5
30h  
0
47/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.123. Query BLANKING — RIGHT  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
4Ch  
L
4Ch  
L
03h  
03h  
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
Acceptability  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN  
REMOTE2  
Yes  
Yes  
No  
Yes  
Yes  
Yes  
Parameters(*1,*2,*3,*4,*5,*6)  
0
30h  
0
1
30h  
0
2
30h  
0
Hexadecimal  
Character  
D10000  
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
698  
39h  
9
699  
39h  
9
700  
30h  
0
Hexadecimal  
Character  
DW10000  
36h  
6
38h  
8
36h  
6
39h  
9
37h  
7
30h  
0
958  
35h  
5
959  
35h  
5
960  
36h  
6
Hexadecimal  
Character  
39h  
9
38h  
8
39h  
9
39h  
9
39h  
9
30h  
0
2.124. Query BLANKING — LEFT  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
4Ch  
L
52h  
R
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
Acceptability  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN  
REMOTE2  
Yes  
Yes  
No  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6)  
0
30h  
0
1
30h  
0
2
30h  
0
Hexadecimal  
Character  
D10000  
30h  
0
30h  
0
30h  
0
31h  
1
30h  
0
32h  
2
698  
39h  
9
699  
39h  
9
700  
30h  
0
Hexadecimal  
Character  
DW10000  
36h  
6
38h  
8
36h  
6
39h  
9
37h  
7
30h  
0
958  
35h  
5
959  
35h  
5
960  
36h  
6
Hexadecimal  
Character  
39h  
9
38h  
8
39h  
9
39h  
9
39h  
9
30h  
0
2.125. Query INSTALLATION  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
53h  
S
50h  
P
Response (Callback)  
FRONT-F  
Hexadecimal  
Character  
02h  
30h  
0
03h  
REAR-F  
Hexadecimal  
Character  
FRONT-C  
Hexadecimal  
Character  
REAR-C  
02h  
02h  
02h  
34h  
1
03h  
03h  
03h  
31h  
2
Hexadecimal  
Character  
32h  
3
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes Yes Yes Yes Yes Yes  
48/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.126. Query PROJECTOR RUNTIME  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
53h  
S
54h  
T
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
*9  
*10  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6, *7, *8, *9, *10)  
0
1
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
30h  
0
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
99998  
39h  
9
99999  
39h  
9
Hexadecimal  
Character  
39h  
9
39h  
9
39h  
9
38h  
8
39h  
9
39h  
9
39h  
9
39h  
9
2.127. Query LAMP RUNTIME  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
24h  
$
4Ch  
L
3Ah  
:
*1  
*2  
03h  
Parameters (*1, *2)  
LAMP1  
31h  
1
LAMP2  
32h  
2
LAMP3  
33h  
3
LAMP4  
34h  
4
Hexadecimal  
Character  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)  
0 h  
1 h  
Hexadecimal  
Character  
30h  
0
30h  
0
30h  
0
30h  
0
30h  
0
30h  
0
30h  
0
31h  
1
9998 h  
9999 h  
Hexadecimal  
Character  
39h  
9
39h  
9
39h  
9
38h  
8
39h  
9
39h  
9
39h  
9
39h  
9
Note:  
• It returns with 65535 (five digits) when LAMP RUNTIME cannot be obtained.  
2.128. Query LAMP SELECT  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
53h  
S
4Ch  
L
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4)  
QUAD  
L1/L4  
31h  
1
L1/L3/L4  
36h  
L2/L3  
32h  
2
L2/L3/L4  
37h  
DUAL  
33h  
3
TRIPLE  
38h  
L1/L2/L3  
34h  
4
L1  
39h  
9
Hexadecimal  
Character  
30h  
0
L1/L2/L4  
35h  
Hexadecimal  
Character  
5
6
7
8
L2  
L3  
L4  
SINGLE  
Hexadecimal  
Character  
31h  
1
30h  
0
31h  
1
31h  
1
31h  
1
32h  
2
31h  
1
33h  
3
Note:  
• The response (callback) of QUAD (0) — L1 (9) is one digit.  
49/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.129. Query Lamp Status  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
53h  
S
03h  
$
Response (Callback)  
Lamp OFF  
Hexadecimal  
Character  
02h  
30h  
0
03h  
In turning ON  
Hexadecimal  
Character  
02h  
02h  
02h  
31h  
1
03h  
03h  
03h  
Lamp ON  
Hexadecimal  
Character  
Cooling  
31h  
2
Hexadecimal  
Character  
33h  
3
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
2.130. Query VPS SYSTEM  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
56h  
V
59h  
Y
03h  
Response (Callback)  
SLAVE  
Hexadecimal  
Character  
02h  
30h  
0
03h  
MASTER  
Hexadecimal  
Character  
02h  
32h  
1
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
2.131. Query TEMP.  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
54h  
T
4Dh  
M
3Ah  
:
Hexadecimal  
Character  
*1  
*2  
03h  
Parameters (*1, *2)  
Intake air  
Exhaust air  
Optical module  
Hexadecimal  
Character  
30h  
0
31h  
1
32h  
2
Response (Callback)  
For –20°C  
Celsius  
Fahrenheit  
30h 30h  
Hexadecimal  
Character  
For 120°C  
02h  
02h  
2Dh  
30h  
0
32h  
30h  
0
2Fh  
/
2Dh  
34h  
4
03h  
2
0
0
Celsius  
Fahrenheit  
32h 34h  
Hexadecimal  
Character  
30h  
0
31h  
1
32h  
2
30h  
0
2Fh  
/
30h  
0
38h  
8
03h  
2
4
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes Yes Yes Yes Yes Yes  
50/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.132. Query ALTITUDE  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
46h  
F
4Dh  
M
03h  
Response (Callback)  
LOW  
Hexadecimal  
Character  
02h  
30h  
0
03h  
HIGH  
Hexadecimal  
Character  
02h  
31h  
1
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
2.133. Query FUNC1  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
46h  
F
43h  
C
03h  
Response (Callback)  
P IN P  
Hexadecimal  
Character  
02h  
30h  
0
03h  
SUB MEMORY LIST  
Hexadecimal  
Character  
SYSTEM SELECTOR  
Hexadecimal  
Character  
02h  
02h  
33h  
3
03h  
03h  
34h  
4
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
2.134. Query Usage Condition of Sub Memory  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
53h  
S
42h  
B
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
No  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4)  
When the sub memory is not used, ER401 is returned.  
01  
02  
94  
03  
95  
04  
96  
Hexadecimal  
Character  
30h  
0
31h  
1
30h  
0
32h  
2
30h  
0
33h  
3
30h  
0
34h  
4
93  
Hexadecimal  
Character  
39h  
9
33h  
3
39h  
9
34h  
4
39h  
9
35h  
5
39h  
9
36h  
6
2.135. Query DVI EDID  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
42h  
E
4Ch  
D
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes Yes Yes Yes Yes Yes  
Parameters (*1, *2)  
EDID1  
EDID2(PC)  
Hexadecimal  
Character  
31h  
1
32h  
2
51/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.136. Query AUX DVI EDID  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
42h  
E
4Ch  
D
3Ah  
:
Hexadecimal  
Character  
41h  
A
55h  
U
58h  
X
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2)  
EDID1  
EDID2(PC)  
Hexadecimal  
Character  
31h  
1
32h  
2
2.137. Query P IN P  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
50h  
P
50h  
P
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2)  
OFF  
30h  
0
USER1  
31h  
1
USER2  
32h  
USER3  
33h  
Hexadecimal  
Character  
2
3
Note:  
• When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
2.138. Query P IN P — MAIN WINDOW  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
49h  
I
4Dh  
M
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2)  
RGB1  
47h  
G
RGB2  
47h  
G
DVI  
56h  
V
Hexadecimal  
Character  
52h  
R
31h  
1
52h  
R
32h  
2
44h  
D
49h  
I
VIDEO  
49h  
I
S VIDEO  
56h  
AUX  
55h  
U
Hexadecimal  
Character  
56h  
V
44hh  
D
53h  
S
44h  
D
41h  
A
58h  
X
V
Note:  
• When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
52/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.139. Query P IN P — MAIN WINDOW:SIZE  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
53h  
S
4Dh  
M
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
Hexadecimal  
Character  
02h  
*1  
*2  
*13  
*14  
*3  
*4  
*15  
*16  
2Ch  
56h  
*5  
*7  
*8  
*17  
*18  
*9  
2Ch  
,
*21  
*22  
48h  
H
03h  
,
2Ch  
,
V
48h  
H
*6  
56h  
V
*10  
*19  
*20  
*11  
*12  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4)  
INTERLOCKED  
OFF  
ON  
Hexadecimal  
Character  
4Fh  
O
46h  
F
4Fh  
O
4Eh  
N
Parameters (*5, *6, *7, *8, *9, *10)  
V SIZE  
10  
11  
12  
13  
14  
Hexadecimal 30h 31h 30h 30h 31h 31h 30h 31h 32h 30h 31h 33h 30h 31h 34h  
Character  
0
1
0
0
1
1
0
1
2
0
1
3
0
1
4
96  
97  
98  
99  
100  
Hexadecimal 30h 39h 36h 30h 39h 37h 30h 39h 38h 30h 39h 39h 31h 30h 30h  
Character  
0
9
6
0
9
7
0
9
8
0
9
9
1
0
0
Parameters (*11, *12, *13, *14, *15, *16)  
H SIZE  
10  
11  
12  
13  
14  
Hexadecimal 30h 31h 30h 30h 31h 31h 30h 31h 32h 30h 31h 33h 30h 31h 34h  
Character  
0
1
0
0
1
1
0
1
2
0
1
3
0
1
4
96  
97  
98  
99  
100  
Hexadecimal 30h 39h 36h 30h 39h 37h 30h 39h 38h 30h 39h 39h 31h 30h 30h  
Character  
0
9
6
0
9
7
0
9
8
0
9
9
1
0
0
Parameters (*17, *18, *19, *20, *21, *22)  
HV SIZE  
10  
11  
12  
13  
14  
Hexadecimal 30h 31h 30h 30h 31h 31h 30h 31h 32h 30h 31h 33h 30h 31h 34h  
Character  
0
1
0
0
1
1
0
1
2
0
1
3
0
1
4
96  
97  
98  
99  
100  
Hexadecimal 30h 39h 36h 30h 39h 37h 30h 39h 38h 30h 39h 39h 31h 30h 30h  
Character  
0
9
6
0
9
7
0
9
8
0
9
9
1
0
0
Note:  
• When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
53/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.140. Query P IN P — MAIN WINDOW:POSITION  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
50h  
P
4Dh  
A
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
2Ch  
,
48h  
H
*9  
*10  
*11  
*12  
*13  
*14  
*15  
*16  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes No Yes Yes Yes Yes  
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)  
V POSITION  
D10000  
505  
504  
35h  
5
503  
35h  
5
Hexadecimal  
Character  
2Dh  
35h  
5
30h  
0
35h  
5
2Dh  
30h  
0
34h  
4
2Dh  
30h  
0
33h  
3
+503  
+504  
+505  
Hexadecimal  
Character  
2Bh  
+
35h  
5
30h  
0
33h  
3
2Bh  
+
35h  
5
30h  
0
34h  
4
2Bh  
+
35h  
5
30h  
0
35h  
3
DW10000  
520  
519  
518  
Hexadecimal  
Character  
2Dh  
35h  
5
32h  
2
30h  
0
2Dh  
35h  
5
31h  
1
39h  
9
2Dh  
35h  
5
31h  
1
38h  
8
+518  
+519  
+520  
Hexadecimal  
Character  
2Bh  
+
35h  
5
31h  
1
38h  
8
2Bh  
+
35h  
5
31h  
1
39h  
9
2Bh  
+
35h  
5
32h  
2
30h  
0
Parameters(*9,*10, *11, *12, *13, *14, *15, *16)  
H POSITION  
D10000  
674  
673  
672  
Hexadecimal  
Character  
2Dh  
36h  
6
37h  
7
34h  
4
2Dh  
36h  
6
37h  
7
33h  
3
2Dh  
36h  
6
37h  
7
32h  
2
+672  
+673  
+674  
Hexadecimal  
Character  
2Bh  
+
36h  
6
37h  
7
32h  
2
2Bh  
+
36h  
6
37h  
7
33h  
3
2Bh  
+
36h  
6
37h  
7
34h  
4
DW10000  
926  
925  
924  
Hexadecimal  
Character  
2Dh  
39h  
9
32h  
2
36h  
6
2Dh  
39h  
9
32h  
2
35h  
5
2Dh  
39h  
9
32h  
2
34h  
4
+924  
+925  
+926  
Hexadecimal  
Character  
2Bh  
+
39h  
9
32h  
2
34h  
4
2Bh  
+
39h  
9
32h  
2
35h  
5
2Bh  
+
39h  
9
32h  
2
36h  
6
Note:  
• When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
2.141. Query P IN P — SUB WINDOW  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
49h  
I
53h  
S
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
*5  
*6  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2)  
RGB1  
47h  
G
RGB2  
47h  
G
DVI  
56h  
V
Hexadecimal  
Character  
52h  
R
31h  
1
52h  
R
32h  
2
44h  
D
49h  
I
VIDEO  
49h  
I
S VIDEO  
56h  
AUX  
55h  
U
Hexadecimal  
Character  
56h  
V
44hh  
D
53h  
S
44h  
D
41h  
A
58h  
X
V
Note:  
• When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
54/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.142. Query P IN P — SUB WINDOW:SIZE  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
53h  
S
53h  
S
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
Hexadecimal  
Character  
02h  
*1  
*2  
*13  
*14  
*3  
*4  
*15  
*16  
2Ch  
56h  
*5  
*7  
*8  
*17  
*18  
*9  
2Ch  
,
*21  
*22  
48h  
H
03h  
,
2Ch  
,
V
48h  
H
*6  
56h  
V
*10  
*19  
*20  
*11  
*12  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4)  
INTERLOCKED  
OFF  
ON  
Hexadecimal  
Character  
4Fh  
O
46h  
F
4Fh  
O
4Eh  
N
Parameters (*5, *6, *7, *8, *9, *10)  
V SIZE  
10  
11  
12  
13  
14  
Hexadecimal 30h 31h 30h 30h 31h 31h 30h 31h 32h 30h 31h 33h 30h 31h 34h  
Character  
0
1
0
0
1
1
0
1
2
0
1
3
0
1
4
96  
97  
98  
99  
100  
Hexadecimal 30h 39h 36h 30h 39h 37h 30h 39h 38h 30h 39h 39h 31h 30h 30h  
Character  
0
9
6
0
9
7
0
9
8
0
9
9
1
0
0
Parameters (*11, *12, *13, *14, *15, *16)  
H SIZE  
10  
11  
12  
13  
14  
Hexadecimal 30h 31h 30h 30h 31h 31h 30h 31h 32h 30h 31h 33h 30h 31h 34h  
Character  
0
1
0
0
1
1
0
1
2
0
1
3
0
1
4
96  
97  
98  
99  
100  
Hexadecimal 30h 39h 36h 30h 39h 37h 30h 39h 38h 30h 39h 39h 31h 30h 30h  
Character  
0
9
6
0
9
7
0
9
8
0
9
9
1
0
0
Parameters (*17, *18, *19, *20, *21, *22)  
HV SIZE  
10  
11  
12  
13  
14  
Hexadecimal 30h 31h 30h 30h 31h 31h 30h 31h 32h 30h 31h 33h 30h 31h 34h  
Character  
0
1
0
0
1
1
0
1
2
0
1
3
0
1
4
96  
97  
98  
99  
100  
Hexadecimal 30h 39h 36h 30h 39h 37h 30h 39h 38h 30h 39h 39h 31h 30h 30h  
Character  
0
9
6
0
9
7
0
9
8
0
9
9
1
0
0
Note:  
• When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
55/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.143. Query P IN P — SUB WINDOW:POSITION  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
50h  
P
53h  
S
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
56h  
V
*1  
*2  
*3  
*4  
*5  
*6  
*7  
*8  
2Ch  
,
48h  
H
*9  
*10  
*11  
*12  
*13  
*14  
*15  
*16  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes No Yes Yes Yes Yes  
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)  
V POSITION  
D10000  
505  
504  
35h  
5
503  
35h  
5
Hexadecimal  
Character  
2Dh  
35h  
5
30h  
0
35h  
5
2Dh  
30h  
0
34h  
4
2Dh  
30h  
0
33h  
3
+503  
+504  
+505  
Hexadecimal  
Character  
2Bh  
+
35h  
5
30h  
0
33h  
3
2Bh  
+
35h  
5
30h  
0
34h  
4
2Bh  
+
35h  
5
30h  
0
35h  
3
DW10000  
520  
519  
518  
Hexadecimal  
Character  
2Dh  
35h  
5
32h  
2
30h  
0
2Dh  
35h  
5
31h  
1
39h  
9
2Dh  
35h  
5
31h  
1
38h  
8
+518  
+519  
+520  
Hexadecimal  
Character  
2Bh  
+
35h  
5
31h  
1
38h  
8
2Bh  
+
35h  
5
31h  
1
39h  
9
2Bh  
+
35h  
5
32h  
2
30h  
0
Parameters (*9, *10, *11, *12, *13, *14, *15, *16)  
H POSITION  
D10000  
674  
673  
672  
Hexadecimal  
Character  
2Dh  
36h  
6
37h  
7
34h  
4
2Dh  
36h  
6
37h  
7
33h  
3
2Dh  
36h  
6
37h  
7
32h  
2
+672  
+673  
+674  
Hexadecimal  
Character  
2Bh  
+
36h  
6
37h  
7
32h  
2
2Bh  
+
36h  
6
37h  
7
33h  
3
2Bh  
+
36h  
6
37h  
7
34h  
4
DW10000  
926  
925  
924  
Hexadecimal  
Character  
2Dh  
39h  
9
32h  
2
36h  
6
2Dh  
39h  
9
32h  
2
35h  
5
2Dh  
39h  
9
32h  
2
34h  
4
+924  
+925  
+926  
Hexadecimal  
Character  
2Bh  
+
39h  
9
32h  
2
34h  
4
2Bh  
+
39h  
9
32h  
2
35h  
5
2Bh  
+
39h  
9
32h  
2
36h  
6
Note:  
• When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
2.144. Query P IN P — FRAME LOCK  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
50h  
P
46h  
F
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes No Yes Yes Yes Yes  
Parameters (*1, *2)  
MAIN WINDOW  
SUB WINDOW  
Hexadecimal  
Character  
30h  
0
31h  
1
Note:  
• When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
56/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.145. Query P IN P — TYPE  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
50h  
P
54h  
T
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2)  
MAIN WINDOW  
SUB WINDOW  
Hexadecimal  
Character  
30h  
0
31h  
1
Note:  
•When FRAME DELAY is set besides DEFAULT, ER401 is returned.  
2.146. Query Date  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
47h  
G
44h  
D
03h  
Response (Callback)  
Hexadecimal  
Character  
02h  
*y1  
*y2  
*y3  
*y4  
*m1  
*m2  
*d1  
*D2  
*w  
03h  
Parameters  
*y1—*y4: Year (4 digits)  
*m1, *m2: Month (2 digits)  
*d1, *d2: Day (2 digits)  
*w: Day of the week (Mon = 1, Tue = 2, Wed = 3, Thu = 4, Fri = 5, Sat = 6, Sun = 7)  
Set it by UTC (Coordinated Universal Time).  
Example: Thursday, June 29, 2006  
*y1  
32h  
2
*y2  
30h  
0
*y3  
30h  
0
*y4  
36h  
6
*m1  
30h  
0
*m2  
36h  
6
*d1  
32h  
2
*D2  
39h  
9
*w  
34h  
4
Hexadecimal  
Character  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
2.147. Query Time  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
47h  
G
54h  
T
03h  
Response (Callback)  
Hexadecimal  
Character  
02h  
*h1  
*h2  
*m1  
*m2  
*s1  
*s2  
03h  
Parameters  
*h1, *h2: Hour (2 digits)  
*m1, *m2Minute (2 digits)  
*s1, *s2Second (2 digits)  
Set it by UTC (Coordinated Universal Time).  
Example: 3 seconds at 3:45 p.m.  
*h1  
31h  
1
*h2  
35h  
5
*m1  
34h  
4
*m2  
35h  
5
*s1  
30h  
0
*s2  
33h  
3
Hexadecimal  
Character  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes Yes Yes Yes Yes Yes  
57/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.148. Query Model (Series) Name  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
49h  
I
44h  
D
03h  
Response (Callback)  
In the period when the command can be accepted  
D10000  
Hexadecimal  
Character  
02h  
44h  
D
31h  
1
30h  
0
30h  
0
30h  
0
30h  
0
03h  
DW10000  
Hexadecimal  
Character  
02h  
44h  
D
57h  
W
31h  
1
30h  
0
30h  
0
30h  
0
30h  
0
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
2.149. Query Lamp ON Status  
Hexadecimal  
Character  
02h  
41h  
A
44h  
D
5Ah  
Z
5Ah  
Z
3Bh  
;
51h  
Q
h
L
h
S
03h  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
Character  
02h  
*1  
*2  
*3  
*4  
03h  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Parameters (*1, *2, *3, *4)  
Lamp OFF  
30h  
0
L1/L2/L4  
35h  
L1/ L2/L3/L4 ON  
L1/L4 on  
32h  
2
L2/L3/L4  
37h  
L2/L3  
33h  
3
L1  
38h  
8
L1/L2/L3  
Hexadecimal  
Character  
31h  
34h  
4
L2  
39h  
9
1
L1/L3/L4  
36h  
Hexadecimal  
Character  
5
6
7
L3  
L4  
Hexadecimal  
Character  
31h  
1
30h  
0
31h  
1
31h  
1
Extended Control Command  
Start  
(STX)  
ID  
Command  
1 byte or 3 bytes  
Parameters  
End  
(ETX)  
1 byte  
1 byte  
Undefined length  
1 byte  
58/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ID of the extended control command  
ID  
Hexadecimal  
(1 byte)  
ID  
Hexadecimal  
(1 byte)  
ID  
ID46  
Hexadecimal  
(1 byte)  
ID  
Hexadecimal  
(1 byte)  
84  
ALL  
00  
01  
02  
03  
04  
05  
06  
07  
08  
09  
0A  
0B  
0C  
0D  
0E  
0F  
10  
11  
12  
13  
14  
15  
16  
ID23  
17  
18  
19  
1A  
1B  
1C  
1D  
1E  
1F  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
2A  
2B  
2C  
2D  
2E  
2F  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
3A  
3B  
3C  
3D  
3E  
3F  
40  
80  
81  
82  
83  
Group E  
Group F  
Group G  
Group H  
Group I  
ID1  
ID24  
ID25  
ID26  
ID27  
ID28  
ID29  
ID30  
ID31  
ID32  
ID33  
ID34  
ID35  
ID36  
ID37  
ID38  
ID39  
ID40  
ID41  
ID42  
ID43  
ID44  
ID45  
ID47  
85  
86  
87  
88  
89  
8A  
8B  
8C  
8D  
8E  
8F  
90  
91  
92  
93  
94  
95  
96  
97  
98  
99  
ID2  
ID48  
ID3  
ID49  
ID4  
ID50  
ID5  
ID51  
Group J  
Group K  
Group L  
Group M  
Group N  
Group O  
Group P  
Group Q  
Group R  
Group S  
Group T  
Group U  
Group V  
Group W  
Group X  
Group Y  
Group Z  
ID6  
ID52  
ID7  
ID53  
ID8  
ID54  
ID9  
ID55  
ID10  
ID11  
ID12  
ID13  
ID14  
ID15  
ID16  
ID17  
ID18  
ID19  
ID20  
ID21  
ID22  
ID56  
ID57  
ID58  
ID59  
ID60  
ID61  
ID62  
ID63  
ID64  
Group A  
Group B  
Group C  
Group D  
2.150. Lens Control  
Hexadecimal  
Remarks  
02h  
STX  
*1  
ID  
B1h  
Command  
7Ch  
*2  
*3  
Parameters  
*4  
03h  
ETX  
Parameters (*2)  
LENS SHIFT H  
00h  
LENS SHIFT V  
LENS FOCUS  
02h  
LENS ZOOM  
Hexadecimal  
01h  
03h  
Parameters (*3)  
Slowly  
00h  
Normal  
01h  
Fast  
02h  
Home position *  
80h  
Hexadecimal  
Parameters (*4)  
Right / Up / Forward / In / Cancel  
00h  
Left / Down / Backward / Out / Start  
01h  
Hexadecimal  
Note:  
• It is effective only when the parameter (*2) is LENS SHIFT H (00h) or LENS SHIFT V (01h).  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
02h  
STX  
*5  
ID  
B3h  
7Ch  
*2  
*3  
*4  
03h  
ETX  
Callback  
Parameters  
In the period when the command cannot be accepted  
Hexadecimal  
02h  
STX  
*5  
ID  
FFh  
Error  
03h  
ETX  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes No Yes Yes Yes Yes  
59/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.151. SELF CHECK Information  
Hexadecimal  
Remarks  
02h  
STX  
*1  
ID  
FEh  
Command  
FEh  
Option  
03h  
ETX  
Response (Callback)  
In the period when the command can be accepted  
Hexadecimal  
02h  
STX  
*5  
ID  
FEh  
FEh  
*2  
*3  
*4  
*15  
*16  
*17  
03h  
Parameters  
Acceptability  
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Parameters (*2—*17)  
Bit  
Name  
Description  
Condition of Clear Bit  
It is less than the specific  
value.  
0
Temperature warning (IN)  
Intake air temperature is the specific value or higher.  
1
2
3
4
5
6
7
Temperature warning (OPT)  
Temperature warning (OUT)  
Low temperature warning (OPT)  
Temperature error (IN)  
Optical module (DMD surroundings) temperature is the  
specific value or higher.  
It is less than the specific  
value.  
Exhaust air temperature is the specific value or higher.  
It is less than the specific  
value.  
Optical module (DMD surroundings) temperature is less than It is the specific value or  
the specific value.  
higher.  
Intake air temperature is the specific value or higher.  
It is less than the specific  
value.  
Temperature error (OPT)  
Temperature error (OUT)  
Low temperature error (OPT)  
Optical module (DMD surroundings) temperature is the  
specific value or higher.  
It is less than the specific  
value.  
Exhaust air temperature is the specific value or higher.  
It is less than the specific  
value.  
Optical module (DMD surroundings) temperature is less than It is the specific value or  
the specific value.  
higher.  
8
Lamp 1 operating time warning  
Lamp 2 operating time warning  
Lamp 3 operating time warning  
Lamp 4 operating time warning  
Lamp 1 operating time exceeded  
Lamp 2 operating time exceeded  
Lamp 3 operating time exceeded  
Lamp 4 operating time exceeded  
Lamp 1 going out  
Lamp cumulative usage time is the specific value or longer.  
Lamp replacement  
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
Lamp cumulative usage time is the specific value or longer.  
Lamp-Goes out after turning on.  
Executes the lamp  
turning on processing.  
Lamp 2 going out  
Lamp 3 going out  
Lamp 4 going out  
Lamp 1 lighting failure  
Lamp ignition failure  
Lamp 2 lighting failure  
Lamp 3 lighting failure  
Lamp 4 lighting failure  
Lamp 1 not installed  
Lamp not installed, or Lamp memory read failure  
MAIN POWER ON after  
the lamp is installed, or  
Lamp memory  
Lamp 2 not installed  
Lamp 3 not installed  
initialization  
Lamp 4 not installed  
AC power supply voltage drop  
warning (less than 90 V)  
Lamp unit cover is not closed  
29  
Lamp unit cover is not closed for 1 second or longer.  
POWER ON after the lamp  
unit cover is closed  
30  
31  
60/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
32  
33  
Thermosensor disconnected (IN)  
Thermosensor disconnected  
(OPT)  
Intake air thermosensor is disconnected.  
MAIN POWER ON  
Optical module (DMD) thermosensor is disconnected.  
34  
Thermosensor disconnected  
(OUT)  
Exhaust air thermosensor is disconnected.  
Airflow sensor is disconnected.  
35  
36  
37  
Airflow sensor disconnected  
Air filter is blocked  
Internal clock battery replacement  
The date is before December 31, 2005 or after January 1,  
2036.  
Sets the date after the  
battery is replaced.  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
62  
63  
64  
65  
66  
67  
68  
69  
70  
71  
72  
73  
74  
75  
76  
77  
78  
79  
80  
81  
Fan error 1  
Power unit fan  
Lamp fan 1  
Fan normal operation  
Fan error 2  
Fan error 3  
Lamp fan 2  
Fan error 4  
Lamp fan 3  
Fan error 5  
Lamp fan 4  
Fan error 6  
Ballast fan 1  
Fan error 7  
Ballast fan 3  
Fan error 8  
Radiator fan  
Fan error 9  
Exhaust fan (C)  
Exhaust fan (L)  
Exhaust fan (R)  
R-DMD fan  
Fan error 10  
Fan error 11  
Fan error 12  
Fan error 13  
Fan error 14  
Fan error 15  
Fan error 16  
Fan error 17  
Fan error 18  
Shutter error  
Dynamic iris error  
Air filter unit error  
2.5 V DC error  
3.3 V DC error  
5.0 V DC error  
Lamp 1 uninitialization  
Lamp 2 uninitialization  
Lamp 3 uninitialization  
Lamp 4 uninitialization  
Lamp 1 PFC error  
Lamp 2 PFC error  
Lamp 3 PFC error  
Lamp 4 PFC error  
FPGA1 configuration error  
FPGA2 SXGA+ configuration error  
Liquid cooling pump (G)  
Liquid cooling pump (B)  
Color prism fan  
Lamp prism fan  
Ballast fan 2  
Ballast fan 4  
Shutter error  
Shutter ON/OFF  
Air filter cleaning processing time-out  
Executes cleaning.  
POWER ON  
The voltage is higher than 120% or lower than 80%.  
Lamp EEPROM is not initialized.  
Lamp EEPROM  
initialization  
61/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
82  
FPGA2 FULL-HD configuration  
error  
83  
84  
85  
86  
87  
88  
89  
90  
91  
92  
93  
94  
95  
96  
97  
FLASH ROM error  
RAM error  
FPGA evolvement error  
Lens shift error  
RESIZE setting error  
Network CPU communication  
error  
MAIN POWER ON  
MAIN POWER ON  
98  
99  
Sub CPU communication error  
IIC communication retry 1  
MAIN POWER ON  
100 IIC communication retry 2  
101 IIC communication retry 3  
102 IIC communication retry 4  
103 IIC communication retry 5  
104 IIC communication retry 6  
105 IIC communication retry 7  
106 IIC communication retry 8  
107 IIC communication retry 9  
108 IIC communication retry 10  
109 IIC communication retry 11  
110 IIC communication retry 12  
111 IIC communication retry 13  
112 IIC communication retry 14  
113 IIC communication retry 15  
114 IIC communication retry 16  
115 A-P.C.Board uninitialization  
A-P.C.Board  
initialization  
POWER ON  
116 FM-R test failure  
RDRAM test error  
117 FM-G test failure  
118 FM-B test failure  
119 FPGA1 setting error  
120 FPGA2 setting error  
121 FM communication error  
Communication error with FM  
MAIN POWER ON  
122  
123  
124  
125  
126 Internal error (Used in main CPU)  
127 Internal error (Used in main CPU)  
All fans have stopped in the factory mode.  
Error Axx has been occurred.  
POWER ON  
When the error Axx  
is canceled  
Note:  
• In this projector, must specify option FEh.  
62/62  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Multiquip Saw Sp 6065 User Manual
Multi Tech Systems Network Card MT2834ZPX User Manual
Murphy Switch WAI Series User Manual
NAD Stereo Receiver L 76 User Manual
National Instruments Model Vehicle OAC5 User Manual
Numark Industries CD Player CDN 36 User Manual
Optiview Security Camera 30XSPDIN User Manual
Optoma Technology Projector H55 User Manual
Panasonic Answering Machine KX TG5240AL User Manual
Panasonic Flat Panel Television BT LH2600WMC User Manual