AC Adapter
AW-PS300
Before attempting to connect or operate this product,
please read these instructions completely.
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
FEATURES ................................................................................................................................................................................... 1
PRECAUTIONS ............................................................................................................................................................................. 2
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS ...................................................................................................... 3
CONNECTION .............................................................................................................................................................................. 6
SPECIFICATIONS ......................................................................................................................................................................... 8
ACCESORY ................................................................................................................................................................................... 8
FEATURES
• This is the AC Adapter for the Pan/tilt Head AW-PH300.
• It has an AC outlet (500 W maximum) for halogen
lamps that can be switched on and off from a Control
Panel (AW-RP301, AW-RP305, AW-RP501, or AW-
RP505).
• The maximum allowable cable length between this
adapter and pan/tilt head is 30 meters.
• It also has an option switch (120V, 1A maximum)
whose contact can be shorted or opened from a
Control Panel (AW-RP301, AW-RP305, AW-RP501, or
AW-RP505).
-1-
Download from Www.Somanuals.com. All Manuals Search And Download.
PRECAUTIONS
• Handle the adaptor with care.
Dropping the control panel or subjecting it to a strong
shock can cause a failure or an accident.
• Care
Pull out the power cable plug, and wipe the control
panel clean with a dry cloth. If it is extremely dirty, dip
a cloth into a diluted solution of kitchen detergent,
squeeze it hard, and wipe the product surfaces care-
fully.
• Operating temperature range –10°C to +45°C
Avoid using it in a cold place below –10°C or a hot
place above +45°C because low or high temperature
will adversely affect the parts inside.
Note
• Do not use benzine, paint thinner, or other volatile
liquids.
• When using a chemical duster, carefully read the
caution notes on its use.
• Switch power off before power cable connection or
disconnection.
Be sure to switch power off before connecting or dis-
connecting the power cable.
• Avoid outdoor use.
• Install the control panel more than 1 meter away
from the monitors.
-2-
Download from Www.Somanuals.com. All Manuals Search And Download.
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS
■ FRONT PANEL
FUSE(POWER)
FUSE(LAMP)
POWER
F U S E
F U S E
OFF
ON
O
I
FUSE
FUSE
T
T
AC Adaptor
AW-PS300
125V 3.15A
125V 6.3A
POWER
q Power Switch (POWER, ON/OFF)
e Fuse [FUSE (POWER)]
Power is switched on to supply power to the pan/tilt
head when this switch is pressed to the ON position
(POWER Indicator lights), and is switched off when the
switch is pressed to the OFF position.
Power fuse. Use a 125V, 3.15A fuse to replace it.
r Lamp Fuse [FUSE (LAMP)]
Halogen lamp fuse. Use a 125V, 6.3A fuse to replace
it.
w Power Indicator (POWER)
Lights red when POWER ON/OFF Switch q is pressed
to the ON position, and goes out when POWER
ON/OFF Switch q is pressed back to the OFF position.
-3-
Download from Www.Somanuals.com. All Manuals Search And Download.
■ FRONT PANEL
LAMP AC OUT
100V 500W
AC IN
OPTION SW OPTION SW
CONTROL OUT CONTROL IN
OP
LAMP
DC 15V
OUT
CONTROL
C
S
+
−
t AC 120V Inlet [AC IN](AC 3P Inlet)
y to short or open, using a cable (to be locally pur-
chased) with a nominal cross section of 0.3 mm or
2
Connect the supplied AC cable.
more that meets the UL specifications. The maximum
allowable cable length is 30 meters.
Applicable Wire
y Option Switch Terminal (OPTION SW CONTROL
OUT) (2P Terminal Board)
A relay switch capable of controlling the contact to
short or open from a Control Panel (AW-RP301, AW-
RP305, AW-RP501, or AW-RP505). The terminal board
has a maximum capacity of 120 V, 1 A (AC/DC), and is
valid when it is connected to OPTION SW CONTROL IN
Terminal u on the pan/tilt head.
Solid wire:
Stranded wire:
Usable wire range
Solid wire:
ø1.02 (AWG 18)
0.75 mm
2
ø0.64 to ø1.02
(AWG 22 to 18)
2
2
Stranded wire:
0.3 mm to 0.75 mm
(AWG 22 to 20)
Strand diameter: ø0.18 or more
Standard bare end length 10 mm
u Option Switch Control Input Terminal (OPTION SW
CONTROL IN) (1P Terminal Board)
Connect it to OP Output Terminal on the pan/tilt head
when controlling OPTION SW CONTROL OUT Terminal
-4-
Download from Www.Somanuals.com. All Manuals Search And Download.
i Lamp Control Input Terminals (LAMP CONTROL
C/S) (2P Terminal Board)
Applicable (usable) wire
Solid wire:
ø1.29 (AWG 16)
2
Connect it to LAMP CONTROL C/S Terminals on the
pan/tilt head when controlling the halogen lamp con-
nected to LAMP AC OUT Connector ! to switch it on
and off, using a cable (to be locally purchased) with a
Stranded wire:
1.25 mm (AWG 16)
Strand diameter ø0.18 or more
Standard bare end length
11 mm
2
nominal cross section of 0.3 mm or more that meets
! Lamp AC Output Connector [LAMP AC OUT]
(AC 3P Outlet)
the UL specifications. The maximum allowable cable
length is 30 meters.
Applicable wire
AC Output Connector for halogen lamps to be
switched on and off from a Control Panel (AW-RP301,
AW-RP305, AW-RP501, or AW-RP505). Locally pur-
chase an AC plug conversion cable that matches the
AC plug for the halogen lamp to be used. Connect a
halogen lamp of 250 W to 500 W. If a halogen lamp of
less than 250 W is connected, the LAMP Indicator on
the control panel may flash to indicate a burnt bulb
even though the lamp is normal.
Solid wire:
Stranded wire:
Usable wire range
Solid wire:
ø1.29 (AWG 16)
1.25 mm (AWG 16)
2
ø0.64 to ø1.29
(AWG 22 to 16)
2
2
Stranded wire:
0.3 mm to 1.25 mm
(AWG 22 to 16)
Strand diameter ø0.18 or more
Standard bare end length 11 mm
o DC 15V Output Terminal (DC 15V OUT +/–)
(2P Terminal Board)
Connect it to (DC 15V IN +/– Terminals) on the pan/tilt
head with a cable (to be locally purchased) with a nom-
2
inal cross section of 1.25 mm or more that meets the
UL specifications. The maximum allowable cable
length is 30 meters.
-5-
Download from Www.Somanuals.com. All Manuals Search And Download.
CONNECTION
• Switch off all the devices before making any connec-
tion.
• Use the Pan/tilt Head AW-PH300.
Applicable wire
Solid wire:
Stranded wire:
Usable wire range
Solid wire:
ø1.29 (AWG 16)
1.25 mm(AWG16)
2
• Connect the DC 15V OUT Terminals [+] and [–] on this
adapter to the DC 15V IN Terminals [+] and [–] on the
Pan/tilt Head (AW-PH300) respectively with cables (to
be locally purchased) with a nominal cross section of
ø0.64 to 1.29 (AWG 22 to 16)
2
2
Stranded wire:
0.3 mm to 1.25 mm
2
(AWG 22 to 16)
1.25 mm or more that meets the UL specifications.
Strand diameter ø0.18 or more
Standard bare end length: 11 mm
The maximum allowable cable length between the
adapter and pan/tilt head is 30 meters.
Applicable (usable) wire
• To control the option switch terminal to short or open
from the control panel, connect the OPTION SW CON-
TROL IN Terminal [OP] on the adapter to the OP
Output Terminal on the pan/tilt head with a cable (to be
locally purchased) with a nominal cross section of 0.3
Solid wire:
Stranded wire:
ø1.29 (AWG 16)
1.25mm (AWG 16)
2
Strand diameter ø0.18 or more
Standard bare end length:
11 mm
2
mm or more that meets the UL specifications. The
• To switch on and off the halogen lamp from the control
panel, connect the LAMP CONTROL Input Terminals
[C] and [S] to the LAMP CONTROL Output Terminals
[C] and [S] on the pan/tilt head respectively with cables
(to be locally purchased) with a nominal cross section
maximum capacity of the option switch terminal is
120V 1A (AC/DC).
Applicable wire
Solid wire:
Stranded wire:
Usable wire range
Solid wire:
ø1.02 (AWG 18)
2
2
0.75 mm
of 0.3 mm or more that meets the UL specifications.
The maximum allowable cable length is 30 meters.
Locally purchase an AC plug conversion cable that
matches the AC plug for the halogen lamp to be used,
and connect a halogen lamp of 250 W to 500 W to the
lamp AC outlet. If a halogen lamp of less than 250 W is
connected, the LAMP Indicator on the control panel
may flash to indicate a burnt bulb even though the
lamp is normal.
ø0.64 to 1.02 (AWG 22 to 18)
2
2
Stranded wire:
0.3 mm to 0.75 mm
(AWG 22 to 20)
Strand diameter ø0.18 or more
Standard bare end length: 10 mm
• For details on the connection, refer to the Operating
Instructions.
-6-
Download from Www.Somanuals.com. All Manuals Search And Download.
• For a detailed description of con-
necting the individual devices,
refer to their Operating
Instructions.
• Connect the supplied AC cable to
the AC 120V inlet. Plug the AC
cable to an AC outlet, and press
the power switch on the adapter
to the ON position.
Pan/tilt Head
AW-PH300
Lamp Control Cable
(Nominal cross section 0.3 mm or
Halogen Lamp
2
more, to be locally purchased)
* Unnecessary if lamp control is
not needed.
DC cable
(Nominal cross section 1.25 mm or
more, to be locally purchased)
2
Option switch control cable
2
(Nominal cross section 0.3 mm or
more, to be locally purchased)
* Unnecessary if option switch
control is not needed.
LAMP AC OUT
100V 500W
AC IN
OPTION SW OPTION SW
CONTROL OUT CONTROL IN
OP
LAMP
DC 15V
OUT
CONTROL
C
S
+
−
Locally purchase an AC plug conversion
cable that matches the halogen lamp AC
plug.
* Unnecessary if no halogen lamp is con-
nected.
AC Cable
(supplied)
Option Unit
120V AC
60Hz
-7-
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS
Source Voltage:
Input Capacity:
Power Output:
120 V AC 60 Hz
552W
DC 15V OUT: DC15V 2.5A, with over-current protect circuit
LAMP AC OUT: 120V AC, max. 500W, min. 250W
Pan/tilt head connecting
cables:
5 cables (2 DC power cables, 2 lamp control cables, 1 option switch control cable)
(in case of using the lamp control and option switch control functions)
Maximum cable length
Operating temperature:
Dimensions:
30 m
–10°C to +45°C (14°F to 113°F)
210(W) x 51(H) x 250(D) mm
8-1/4”(W) x 2”(H) x 9-7/8”(D)
2.5 kg (5.5 lbs.)
Weight:
Finish:
AV Ivory baking
Weight and dimensions indicated are approximate.
Specifications are subject to change without notice.
ACCESORY
AC Cable .......................................................................1 pc.
-8-
Download from Www.Somanuals.com. All Manuals Search And Download.
Broadcast & Television Systems Company
Division of Matsushita Electric Corporation of America
Executive Office: One Panasonic Way 2E-6, Secaucus, NJ 07094
Regional Offices:
EASTERN ZONE: 43 Hartz Way, Secaucus, NJ 07094 (201) 348-7620
CENTRAL ZONE: 1707 North Randall Road, Elgin, IL 60123 (847) 468-5200
SOUTHERN ZONE:
Atlanta Region: 1225 Northbrook Parkway, Suite 1-160, Suwanee, GA 30174
Panazip 11 (770) 338-6841, fax (770) 338-6741
Law Enforcement Video Products: 1225 Northbrook Parkway, Suite 1-160, Suwanee, GA
30174, Panazip 11 (770) 338-6844, fax (770) 338-6721
WESTERN ZONE:
Los Angeles Region: 6550 Katella Ave. 17A-1, Cypress, CA 90630 (714) 373-7271
Government Marketing Department: 52 West Gude Drive, Rockville, MD 20850 (301) 738-3840
PANASONIC CANADA INC.
5770 Ambler Drive, Mississauga, Ontario, L4W 2T3 Canada (905) 624-5010
PANASONIC SALES COMPANY
DIVISION OF MATSUSHITA ELECTRIC OF PUERTO RICO, INC.
San Gabriel Industrial Park, 65th Infantry Ave. KM. 9.5 Carolina, Puerto Rico 00630 (809) 750-4300
N1197-0
7J1A110A
Printed in Japan
Download from Www.Somanuals.com. All Manuals Search And Download.
|