Studio SDI Card
AW-PB506AL
This product consists of an SDI card and an
interface bracket.
Before attempting to connect, operate or adjust this product,
please read these instructions completely.
Download from Www.Somanuals.com. All Manuals Search And Download.
Information on Disposal for Users of Waste Electrical & Electronic
Equipment (private households)
This symbol on the products and/or accompanying documents
means that used electrical and electronic products should not be
mixed with general household waste.
For proper treatment, recovery and recycling, please take these
products to designated collection points, where they will be accepted
on a free of charge basis. Alternatively, in some countries you may
be able to return your products to your local retailer upon the purchase of an
equivalent new product.
Disposing of this product correctly will help to save valuable resources and prevent
any potential negative effects on human health and the environment which could
otherwise arise from inappropriate waste handling.
Please contact your local authority for further details of your nearest designated
collection point.
Penalties may be applicable for incorrect disposal of this waste, in accordance with
national legislation.
For business users in the European Union
If you wish to discard electrical and electronic equipment, please contact your
dealer or supplier for further information.
Information on Disposal in other Countries outside the European
Union
This symbol is only valid in the European Union.
If you wish to discard this product, please contact your local authorities or dealer
and ask for the correct method of disposal.
Download from Www.Somanuals.com. All Manuals Search And Download.
- ꢀ (E) -
Contents
Configuration ........................................ 3
Accessories .......................................... 3
Introduction ........................................... 4
Characteristics ...................................... 4
Precautions for use .............................. 4
Connections .......................................... 9
When configuring a system
with the remote control unit ......... 9
When configuring a system
with the remote operation panel ... 10
Setting and changing of menu items ... 11
Performing the settings .................. 11
Optional card settings submenu .... 1ꢀ
Major operating controls and
their functions ................................. 5
SDI card ........................................... 5
Interface bracket .............................. 6
Appearance ......................................... 14
SDI card ......................................... 14
Interface bracket ............................ 15
Installing the SDI card .......................... 7
Specifications ..................................... 16
Interface bracket mountings ............... 8
Mounting the bracket on a tripod ..... 8
Mounting the camera ....................... 8
Mounting the viewfinder
on a bracket.................................. 8
Configuration
SDI card (AW-PB506A U01) ................... 1
Interface bracket (AW-PB506A U02) .... 1
Accessories
Adjuster plug (M6 M3) ........................ 1
Screws (6 mm) ....................................... 2
Screws (8 mm) ....................................... 4
Download from Www.Somanuals.com. All Manuals Search And Download.
- ꢀ (E) -
Introduction
Installing the SDI card in a convertible
camera (such as the AW-Eꢀ50, AW-E650,
AW-E655, AW-E750 and AW-E860) and
mounting the camera on the interface
bracket makes it possible for a viewfinder
and/or inter-communications headset to
be used and thus enable the camera to
be used as a studio camera. In addition,
there are two signal outputs for SDI signals
Notes
The AW-PB506A cannot be installed
to the following models;
AW-Eꢀ00, AW-Eꢀ00A, AW-Eꢀ00S,
AW-E600, AW-E800, AW-E800A,
AW-RP605, AW-PB605
When the SDI card unit is to be
discarded at the end of its service
life, ask a specialized contractor
to dispose of it properly in order to
protect the environment.
c
ompliant with EBU Tech.ꢀꢁ67-E standard.
Characteristics
Two signal outputs for SDI signals
compliant with the EBU Tech.ꢀꢁ67-E
standard (BBC No. PSF1/ꢁM, BELDEN
8ꢁ81 or equivalent coaxial cable; max.
ꢁ00 m)
EDH (Error Detection and Handling)
flags complying with the SMPTE RP165
standard can be added.
Output signals (brightness and
composite video signals) to the
viewfinder can be switched using the
menu settings.
Zebra pattern and safety zone displays
appearing in the viewfinder can be
switched using the menu settings.
(A switch can be used to enable or
disable the addition of these flags.)
The VIDEO ON/OFF switch function of
the viewfinder (AW-VF64) is incorporated.
(In order to prevent CRT burn-in, the
AW-VF64 does not come with a standby
function.)
An inter-communications headset can be
used and its volume adjusted.
The STANDBY/ON switch function of
the viewfinder (WV-VF65B, AW-VF80) is
incorporated.
Precautions for use
When connecting or disconnecting a
cable from any unit, ensure that the
power to that unit is turned off.
Avoid using the unit in very humid or
dusty locations, as this may cause it to
malfunction.
Do not drop this product or subject it to
strong shock or vibration, as this may
cause it to malfunction.
Avoid using the product at a cold place
below –10°C or at a hot place above
+45°C because extremely low or high
temperature will adversely affect the
parts inside.
Download from Www.Somanuals.com. All Manuals Search And Download.
- 4 (E) -
Major operating controls and their functions
SDI card
2: Model selection <E350/E860>
(Factory setting: Eꢁ50)
EVF I/F connector [EVF I/F]
The EVF I/F cable 9 from the interface
bracket is connected here.
When the AW-Eꢁ50, AW-E650,
AW-E655 or AW-E750 is used, set
this switch at the Eꢁ50.
When the AW-E860 is used, set this
switch at the E860.
SDI output 1, 2 connector
[SDI OUT 1, 2]
SDI signals are output from here.
3: DATA CLIP <NORMAL/CLIP>
(Factory setting: NORMAL)
At the NORMAL setting, signal input
is output at the same level at which it
was input.
Setting switches
At the CLIP setting, signal input at
less than 0% is output at 0%, and
signal input at more than 100% is
clipped at 100%.
SW NO
EDH
SETTING
OFF
ON
1
ꢀ
ENABLE DISABLE
Eꢁ50
E860
CLIP
PAL
4: NTSC/PAL switching <NTSC/PAL>
(Factory setting: NTSC)
ꢁ DATA CLIP NORMAL
4 NTSC/PAL NTSC
Leave this switch at the factory setting.
1: EDH <ENABLE/DISABLE>
(Factory setting: ENABLE)
An EDH flag is added to SDI output at
the ENABLE setting.
Download from Www.Somanuals.com. All Manuals Search And Download.
- 5 (E) -
Major operating controls and their functions
Interface bracket
EVF connector 1 [EVF1]
The viewfinder (WV-VF65B, AW-VF80)
is connected here.
7
Inter-communications level control
[LEVEL]
This adjusts the sound level output to
the inter-communications headset.
5EVF connector 2 [EVF2]
The viewfinder AW-VF64 is connected
here.
8Inter-communications jack (M3)
[INCOM]
The inter-communications headset is
connected here.
If the plug diameter does not match, use
the adjuster plug (M6 Mꢁ) supplied
with this product.
Note
Do not connect EVFs to EVF
connectors 1 and ꢀ ( and 5) at
the same time.
MIC:
Dynamic (With Preamp)
50 /–ꢀ0 dB
6EVF standby / VIDEO ON/OFF
switch
Receiver: 150 (max. ꢀ00 mW)
[ST.BY / VIDEO ON/OFF]
<For the WV-VF65B, AW-VF80>
ST.BY: Places the viewfinder in standby
mode.
9EVF I/F cable
This is connected to the EVF I/F
connector on the SDI card.
ON:
Outputs images to the viewfinder.
TALLY input connector [TALLY IN]
This is the tally control external input
connector.
<For the AW-VF64>
VIDEO ON: Outputs images to the
viewfinder.
VIDEO OFF: No images appear on the
viewfinder.
OPEN: TALLY OFF
SHORT: TALLY ON
When using the AW-CB400 remote
operation panel and AW-CA50T8G
control cable for connecting to the
convertible camera, connect the TALLY
cable of the AW-CA50T8G to this
connector.
The AW-VF64 does not come with a
standby function.
Download from Www.Somanuals.com. All Manuals Search And Download.
- 6 (E) -
Installing the SDI card
Always ask your local dealer to install the SDI card.
Before installing the SDI card:
Release the static carried in the body of the person to perform the installation.
Installation can be performed more safely if an anti-static wrist strap is worn.
Touching the card without first releasing this static may cause malfunctioning.
Do not allow the metal part of the card come in contact with any other metal parts.
Rear panel
Optional card
slot cover
SDI card
2 screws (6 mm)
4 screws (8 mm)
1
5
6
Turn the power to the camera off
and remove any cables which are
connected to the power connector or
other connectors.
Firmly tighten the ꢀ screws (6 mm) to
the optional card slot.
Firmly secure the rear panel with the
4 screws (8 mm).
2
3
4
Loosen the 4 screws (8 mm) on the
rear panel of the camera, then remove
the panel itself.
Note
If the screws are misplaced, use
the extra screws supplied with this
product.
Loosen the ꢀ screws (6 mm) on the
optional card slot cover, then remove
the cover.
Align the SDI card with the guides and
insert it.
Ensure the card is fully inserted.
Download from Www.Somanuals.com. All Manuals Search And Download.
- 7 (E) -
Interface bracket mountings
Mounting the bracket
on a tripod
Mounting the viewfinder
on a bracket
3
1
Mount the mounting base that is
supplied to the viewfinder onto the top
of the interface bracket using the ꢀ
screws provided.
Mount the interface bracket on the
tripod. (Screw: 1/4 – ꢀ0UNC)
(Mount the base securely so that it is
not unsteady.)
Mounting base
2 screws
4
5
6
Slide the viewfinder onto the mounting
base and tighten the fixing knob to
secure it firmly.
Connect the viewfinder cable to the
EVF connector 1 or ꢀ on the interface
bracket.
Mounting the camera
2
Mount the camera (in which the
SDI card has been installed) on the
interface bracket.
Connect the EVF I/F cable from
the interface bracket to the EVF I/F
connector on the SDI card.
Fasten the fixing knob to firmly secure
the camera.
<WV-VF65B,
AW-VF80, etc.>
Fixing knob
Fixing knob
Fixing knob
<AW-VF64>
Download from Www.Somanuals.com. All Manuals Search And Download.
- 8 (E) -
Connections
When configuring a system with the remote control unit
Convertible camera:
AW-Eꢀ50, AW-E650, AW-E655,
Inter-communications headset
Video monitor
AW-E750, AW-E860, etc.
SDI monitor
Viewfinder:
WV-VF65B, AW-VF80, AW-VF64, etc.
Use the RCU cable (AW-CA50Aꢁ6) to
connect the remote control unit to the
convertible camera.
Power to the camera is supplied from the
remote control unit.
Remote control unit (RCU):
WV-RC700A, WV-RC550, AW-RC600,
etc.
Inter-communications headset
Viewfinder:
WV-VF65B, AW-VF80,
AW-VF64, etc.
Convertible camera:
AW-Eꢀ50, AW-E650, AW-E655,
AW-E750, AW-E860, etc.
SDI monitor
SDI output
Coaxial cable:
BBC No. PSF1/ꢁM, BELDEN
8ꢁ81 or equivalent coaxial
cable max. ꢁ00 m
Remote control unit (RCU):
WV-RC700A, WV-RC550,
AW-RC600, etc.
Video monitor
Composite signals
Coaxial cable
Inter-communications headset
RCU cable:
AW-CA50Aꢁ6
Download from Www.Somanuals.com. All Manuals Search And Download.
- 9 (E) -
Connections
When configuring a system with the remote operation panel
Convertible camera:
AW-Eꢀ50, AW-E650, AW-E655,
AW-E750, AW-E860, etc.
Use the control cable (AW-CA50T8G) to
connect the remote operation panel to
the convertible camera.
Use the AW-PS505A AC adapter, which
is an optional accessory, for the power
supply.
Viewfinder:
WV-VF65B, AW-VF80, AW-VF64, etc.
Remote operation panel:
AW-CB400, etc.
Inter-communication between the
remote operation panel and studio SDI
card is not possible.
Video monitor
SDI monitor
Viewfinder:
WV-VF65B, AW-VF80,
AW-VF64, etc.
TALLY cable
Convertible camera:
AW-Eꢀ50, AW-E650,
AW-E655, AW-E750,
AW-E860, etc.
SDI monitor
Coaxial cable:
SDI output
BBC No. PSF1/ꢁM, BELDEN
8ꢁ81 or equivalent coaxial
cable max. ꢁ00 m
AC adapter:
AW-PS505A
Cable provided
with AC adapter
Remote operation
panel:
AW-CB400, etc.
Video monitor
10BASE-T
straight cable
Cable provided with AC adapter
AC adapter:
AW-PS505A
Control cable:
AW-CA50T8G
Download from Www.Somanuals.com. All Manuals Search And Download.
- 10 (E) -
Setting and changing of menu items
Camera settings to match the system configuration and filming conditions can be made
using the menu screens.
See the convertible camera operating instructions for more information on the settings.
For details on the setting procedures when the remote control unit and remote operation
panel are used, refer to the operating instructions of the unit and panel.
Main menu for user mode
Performing the settings
1
Display the main menu.
When performing the settings with
the convertible camera:
Press the MENU switch continuously
for at least 5 seconds.
When performing the settings with
the remote control unit (AW-RC600):
Set the MENU switch to “ON”.
* “Option Card 2” is displayed on the
menu when the optional card has been
Main menu for halogen light mode,
fluorescent light mode and outdoor mode
plugged into the optional card slot of
the additional card box.
The mode selected is displayed here.
Convertible camera
MENU switch
ITEM/AWC switch
YES/ABC switch
NO/BAR switch
To return to filming mode
(This is displayed when the convertible
camera is used to perform the settings.)
Remote control unit (AW-RC600)
MENU switch
ITEM UP switch
ITEM DOWN switch
DATAYES/UP switch
DATA NO/DOWN switch
Download from Www.Somanuals.com. All Manuals Search And Download.
- 11 (E) -
Setting and changing of menu items
2
4
Select “Option Card 1” to display the
submenu.
Return to filming mode.
When performing the settings with
the convertible camera:
Press the MENU or ITEM/AWC
switch and select “End” on the main
menu, then press the YES/ABC
switch.
When performing the settings with
the convertible camera:
Press the MENU or ITEM/AWC
switch to move the flashing to the
setting item, then press the YES/ABC
switch to display the submenu.
When performing the settings with
the remote control unit (AW-RC600):
Set the MENU switch to “OFF”.
When performing the settings with
the remote control unit (AW-RC600):
Press the ITEM UP or ITEM DOWN
switch to move the flashing to the
setting item, then press the DATA
YES/UP switch to display the
submenu.
After being returned to filming mode,
the convertible camera will operate as
per the changed settings.
3
Select the setting item and change the
setting.
When performing the settings with
the convertible camera:
Press the MENU or ITEM/AWC
switch to move the flashing to the
desired setting item, then press
the YES/ABC or NO/BAR switch to
change the setting.
When performing the settings with
the remote control unit (AW-RC600):
Press the ITEM UP or ITEM DOWN
switch to move the flashing to the
desired setting item, then press the
DATA YES/UP or DATA NO/DOWN
switch to change the setting.
Download from Www.Somanuals.com. All Manuals Search And Download.
- 1ꢀ (E) -
Setting and changing of menu items
Optional card settings submenu
Safety zone (1 to 4, OFF)
This selects the type of safety zone that
is displayed in the viewfinder.
If “OFF” is selected, a safety zone will
not be displayed.
<Note>
The safety zone and the center marker
reflect the electrical positions which may
differ from the optical positions.
Zebra indicator (ON, OFF)
This sets the zebra pattern display
which appears in the viewfinder.
ON: Zebra patterns are displayed in
the viewfinder.
OFF: Zebra patterns are not displayed
in the viewfinder.
<Note>
Even if “ON” is selected for this setting,
the zebra patterns will not be displayed
in the viewfinder if “CVBS” has been
selected as the EVF output setting.
The inner frame and the outer frame
are approximately 90% and 95%,
respectively, of the safety zone.
Level (70% to 110%)
EVF output (Y, CVBS)
This sets the signals to be output to the
viewfinder.
The zebra patterns are displayed to use
as a yardstick for the brightness level.
Y:
Brightness signals are output to
the viewfinder.
<Note>
These settings are available when
“ON” has been selected for the Zebra
indicator setting.
CVBS: Color signals are output to the
viewfinder.
<Note>
The zebra pattern is not displayed in
the viewfinder when “CVBS” has been
selected.
Download from Www.Somanuals.com. All Manuals Search And Download.
- 1ꢀ (E) -
Appearance
Unit: mm
SDI card
70
Download from Www.Somanuals.com. All Manuals Search And Download.
- 14 (E) -
Appearance
Unit: mm
Interface bracket
50
190
141
30
Download from Www.Somanuals.com. All Manuals Search And Download.
- 15 (E) -
Specifications
Power requirements: DC 1ꢁ V (supplied from convertible camera)
Power consumption: 15 W (When WV-VF65B, AW-VF80 is connected)
indicates safety information.
Ambient operating temperature: –10°C to +45°C
Ambient operating humidity:
ꢀ0% to 90% (without condensation)
Dimensions (WHD):
SDI card
ꢁ1.5709ꢁ mm (excluding protrusions)
Interface bracket
19018ꢀ171 mm (excluding protrusions)
Weight:
SDI card
Interface bracket
0.10 kg
1.06 kg
Input/output connectors:
SDI card
SDI OUT 1, ꢁ connector
EVF I/F connector
Interface bracket
EVF connector 1
BNC, compliant with EBU Tech.ꢀꢁ67-E standard
10-pin, round
10-pin, round, composite signals/brightness, 1.0 V [P-P]
EVF connector ꢁ
6-pin, round, composite signals/brightness, 1.0 V [P-P]
Inter-communications jack
TALLY input connector
Mꢀ
BNC
Switch/control functions:
SDI card
• EDH
• Model selection
• DATA CLIP
ENABLE/DISABLE
Eꢀ50/E860
NORMAL/CLIP
• NTSC/PAL switching NTSC/PAL
EVF standby / VIDEO ON/OFF switch
WV-VF65B, AW-VF80 ST.BY/ON
Interface bracket
Menu screens
AW-VF64
VIDEO ON/VIDEO OFF
Inter-communications level control
Zebra indicator (ON/OFF)
Level (70% to 110%)
Safety zone (1/ꢁ/ꢀ/4/5/OFF)
EVF output (Y/CVBS)
Weight and dimensions indicated above are approximate.