User’s Manual   
					LGP Series   
					Handheld CCD Scanner   
					25-ULGPMU01-01   
					April 2002   
					Keyboard Wedge Interface   
					USB Interface   
					RS232 Interface   
					8 Olympic Drive   
					Orangeburg, NY 10962   
					Tel 845.365.0090   
					Fax 845.365.1251   
					
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
		
			
				 
			 
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Table of Contents   
					PART I CCD Scanning   
					Part III Bar Code Menu Functions   
					Section A Programming the Scanner……………….13   
					
					Unpacking   
					Factory Technical Support   
					Section B Symbology Selections ..................... 14   
					Enabling only a single symbology...................... 14   
					Enabling additional symbology......................... 16   
					Number of Characters…………………………….........18   
					Setting Options for UPC-A/E ............................. 19   
					Setting Options for EAN-13 and -8 .................... 21   
					Code 39 Settings ............................................. 23   
					Codabar Settings ............................................. 25   
					2 of 5 Settings................................................. 28   
					MSI/Plessey Setting ......................................... 30   
					Code 128 Setting............................................. 31   
					IATA Settings .................................................. 32   
					Part II Installation and SetUp   
					A. Installation –Wedge Interface ……………5   
					Reset all Defaults …………………………………………….6   
					
					Keyboard Wedge and USB Option…………………7   
					InterCharacter Delay ..........................................8   
					Section C: Universal Selections   
					B. Installation – RS232 Interface................ 9   
					
					
					
					Case Conversion.............................................. 34   
					Prefix Options.................................................. 35   
					Suffix Options.................................................. 37   
					Direct Input - Keyboard Keys............................ 39   
					Direct Input - Characters ................................ 42   
					Direct Input - Control Characters ...................... 50   
					Read Mode Settings......................................... 53   
					Trigger Settings............................................... 54   
					Beeper Options................................................ 58   
					Good Read Indicator (LED)............................... 60   
					
					_________________________________________   
					NOTICE   
					Opticon has taken every step to ensure that the   
					information included in this manual is accurate,   
					however we reserve the right to change any   
					specification at any time without prior notice.   
					_________________________________________   
					Page 3   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
				 
			 
			
				
					Manual No. 25-ULGPMU01-01   
					Part I   
					Series LGP Handheld CCD Scanner   
					General Information   
					The LGP-6125 Series CCD Scanners utilize state-of-the-art imaging technology similar to that found in digital cameras,   
					facsimile machines and video camcorders. The scanner images the bar code label, then converts the digital signals into data   
					the host computer can understand. By capturing the bar code image all at once, the scanner provides fast, highly accurate   
					reading.   
					Miniature surface mount electronics make up the CCD scanner's solid state construction. CCD scanners have no moving   
					mechanical parts and provide years of trouble-free operation.   
					This manual contains information on setting-up the scanner as well as programming various parameters of the scanner.   
					The LGP6125 scanner is available in several different interface configurations:   
					Keyboard Wedge Interface   
					RS232 Serial Interface   
					USB Interface   
					There is a specific section of this manual for installing each type of interface. Be sure you are using the section of the   
					manual that pertains to interface you are using.   
					Unpacking   
					Remove the scanner from its packaging and inspect it for damage. If the scanner was damaged in transit, call the dealer or   
					distributor from whom you purchased it. If you purchased it directly from Opticon, call Opticon Customer Service Dept. at   
					800-636-0090.   
					Factory Technical Support   
					If you have any questions or need assistance with programming your scanner call Opticon Technical Support at 800-636-   
					0090 please have the unit model number and several bar code labels readily at hand. The model number is located near the   
					connector end of the cable.   
					If the scanner must be returned, please contact Opticon to obtain an RMA (Return Merchandise Authorization) number prior   
					to returning the product. The Customer Service Dept. may be reached at 800-636-0090.   
					NOTE: Returned merchandise will not be accepted without a RMA number indicated clearly on the outside of the carton.   
					Page 4   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
				 
			 
		 
		
			
				 
			 
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Part II Installation and SetUp   
					This section of the manual contains information on the physical installation of the scanner as well as certain programming options.   
					There is a separate section for each type of interface. Check to see which type of interface your scanner has and turn to that   
					section for information on installing the scanner   
					A.) Installation – Keyboard Wedge Interface   
					A "Y" connection cable is required for installation. The scanner is installed or "wedged" between the keyboard and the computer..   
					Your “Y” cable should have connectors for both a PS2 and AT type installation. The "Y" cable connects both the scanner and the   
					keyboard to the computer.   
					The scanner must match the type of computer being used. The default setting is for an IBM AT type computer. If this type does   
					not match the host computer, refer to the “Computer Type Selection” in the programming section that follows. If the connector   
					does not match the host compute remove the short cable section, reverse it and insert it in the other connector   
					Page 5   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
				 
			 
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Reset All Defaults – Keyboard Wedge Interface   
					Our scanners are shipped with factory default settings that represent the settings most commonly used by our customers. In most   
					applications, the scanner will work right out of the box without any need for additional programming. At any time you can return   
					the scanner to the factory default settings. First scan the Start Program Menu bar code below, then scan the “Reset all Defaults”   
					programming bar code, and then the End Program Menu bar.   
					NOTE: (   
					) A pointing finger indicates default settings throughout the following menus.   
					% 
					Start   
					Program Menu   
					ZZ   
					[[   
					Reset All Defaults   
					UB   
					(AT Wedge)   
					VC   
					
					End   
					Program Menu   
					ZZ   
					[[   
					Computer Type Selection (for Keyboard Wedge only)   
					The Keyboard Wedge interface scanner is designed to operate with an IBM personal computers and compatibles along with a   
					Macintosh PC's. Select the host computer type from the menu below.   
					NOTE: If the scanner has not been set to the correct host computer, the scanner may display random characters on the screen after   
					reading a bar code label.   
					Start   
					Program Menu   
					ZZ   
					[[   
					IBM PC/XT   
					UA   
					VB   
					IBM AT &   
					compatibles   
					UB   
					VC   
					VE   
					VN   
					[[   
					
					HP Vectra   
					Macintosh   
					UD   
					UM   
					ZZ   
					End   
					Program Menu   
					Page 6   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Keyboard Wedge and USB options   
					With Keyboard: Use this mode in case a keyboard is connected to the PC wedge Y-cable. The Wedge is only listening in case the   
					computer is booting or the wedge is idle.   
					Without Keyboard: Use this mode in case no keyboard is connected to the PC wedge Y- cable. In some cases, this mode is   
					required when a PC USB keyboard is connected. If this option is enable, the computer detects the wedge as a keyboard. If the   
					computer reports a keyboard error or in case no data is displayed, try this option. It is required to power OFF the PC, wait 10   
					seconds and power ON the PC.   
					NOTE: Do not enable ‘without keyboard’ option when a keyboard is connected to the Y cable. The ‘without keyboard’ option is   
					only supported for PC/AT wedges.   
					Start   
					Program Menu   
					ZZ   
					[[   
					With keyboard   
					KM   
					LN   
					LM   
					[[   
					
					Without keyboard   
					KL   
					ZZ   
					End   
					Program Menu   
					Page 7   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Intercharacter Delay for Keyboard Wedge interface   
					The scanner may send data faster than the computer or application program can accept. This is called "keyboard buffer overrun".   
					If data appears to be missing, random read errors occur or the scanner locks up and will not scan, experiment with the various   
					keyboard timing options listed in the menu to follow.   
					Start Program   
					ZZ   
					Menu   
					[[   
					No Delay   
					LA   
					MB   
					
					Delay = 1   
					LB   
					MB   
					Delay = 2   
					LC   
					MD   
					Delay = 3   
					LD   
					ME   
					Delay = 4   
					LE   
					MF   
					Delay = 5   
					LF   
					MG   
					Delay = 6   
					LG   
					MH   
					Delay = 7   
					LH   
					MI   
					Delay = 8   
					LI   
					MJ   
					Delay = 9   
					LJ   
					MK   
					Delay = 10   
					LK   
					ML   
					End Program   
					ZZ   
					Menu   
					[[   
					+ 
					Page 8   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
				 
			 
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					B.) Installation – RS232 Interface   
					The RS-232 scanner cable is terminated in with a DB9 female connector. An external power supply (+5V DC) may be necessary.   
					There is a power supply jack on the RS-232 connector.   
					Installation is as follows:   
					1. Plug the scanner into an RS232 serial port (such as COM1) of the host PC. If external power is required, insert external power   
					plug into the jack on the RS-232 connector.   
					2. Connect the power supply into an electrical outlet (110 V AC)   
					3. Turn on the power to the host computer. Make sure the communication parameters of the computer match those of the   
					scanner. The default communications settings are: 9600 baud, 8 data bits, 1 stop bit, no parity, no handshaking   
					4. Be sure the PC is in a program (such as WordPad) that will accept input from the serial port.   
					Reset All Defaults – RS232   
					Our scanners are shipped with factory default settings that represent the settings most commonly used by our customers. In most   
					applications, the scanner will work right out of the box without any need for additional programming. At any time you can return   
					the scanner to the factory default settings by scanning the “Reset all Defaults” programming bar codes below. First scan the Start   
					Program Menu bar code below, then scan the “Reset all Defaults” programming bar code, and then the End Program Menu bar.   
					Start   
					Program Menu   
					ZZ   
					[[   
					RS232   
					Reset all defaults   
					U2   
					V3   
					End   
					Program Menu   
					ZZ   
					[[   
					Page 9   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					RS-232C Communication Parameters   
					Handshaking Protocol   
					Start   
					Program   
					Menu   
					ZZ   
					P0   
					[[   
					Q1   
					None   
					
					RTS/CTS   
					ACK/NAK   
					Xon/Xoff   
					HP04   
					P3   
					+IQ15+   
					Q!   
					ZG   
					[H   
					Flow   
					Control   
					Time   
					I0   
					J1   
					
					Unlimited   
					Flow   
					Control:   
					100ms   
					I1   
					I2   
					I3   
					J2   
					J3   
					J!   
					Flow   
					Control:   
					200ms   
					Flow   
					Control:   
					400ms   
					Baud Rate   
					19200   
					9600   
					4800   
					2400   
					1200   
					600   
					K7   
					K6   
					K5   
					K4   
					K3   
					K2   
					L8   
					L7   
					L6   
					L5   
					L!   
					L3   
					
					Page 10   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Data Bits / Stop Bits / Parity   
					7 Data Bits   
					L0   
					L1   
					L5   
					L6   
					L3   
					L4   
					L2   
					ZZ   
					M1   
					M2   
					M6   
					M7   
					M!   
					M5   
					M3   
					[[   
					8 Data Bits   
					1 Stop Bit   
					2 Stop Bits   
					
					
					Even   
					Parity   
					Odd   
					Parity   
					Mark   
					No Parity   
					
					End   
					Program   
					Menu   
					Page 11   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					C.) Installation – USB Interface   
					Plug the scanner into the USB connector on your host computer. PC must be running Windows 98 or higher or iMac Rev A or   
					higher. The computer will sense the presence of the scanner and load any required software drivers automatically.   
					Reset All Defaults - USB Interface   
					Our scanners are shipped with factory default settings that represent the settings most commonly used by our customers. In most   
					applications, the scanner will work right out of the box without any need for additional programming. At any time you can return   
					the scanner to the factory default settings by scanning the “Reset all Defaults” programming bar code below.   
					Start   
					Program   
					Menu   
					ZZ   
					SU   
					ZZ   
					[[   
					TV   
					[[   
					USB   
					End   
					Program Menu   
					Page 12   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
				 
			 
		 
		
			
				 
			 
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Part III   
					Bar Code Menu Functions   
					Section A Programming the Scanner   
					This manual contains information that allows you to easily change certain programmable parameters of the scanner. The scanner is   
					ready to use - no additional programming is required in most situations. The scanner has been programmed at the factory with the   
					most common settings. These factory default settings are ideal for most situations.   
					A specific parameter is set or changed by scanning one or more of the special programming bar codes found on the following   
					pages. For each parameter, you can choose from a menu of options. When you scan the special bar code for a specific menu   
					option, the scanner retains the changes you have made even if you disconnect the scanner or t-urn off the power.   
					Step-by-Step   
					Programming is easy. Simply:   
					1. Scan the bar code for "Start/End Program Menu" (ZZ). The scanner will beep continuously to indicate that it is ready to be   
					programmed. When the scanner is in Programming Mode, it cannot read normal bar code. It can only read the special bar   
					codes found on the following pages.   
					2. Select desired parameter from menu and scan the bar code. The scanner will beep once and the green light will flash,   
					indicating the desired parameter has been scanned. The scanner will continue to beep continuously while in Programming   
					Mode.   
					3. Scan "Start/End Program Menu" (ZZ). The scanner will stop beeping, indicating that it is back in normal scanning mode.   
					The changes made while in Programming Mode are now saved in the scanner's memory.   
					When the scanner is in Programming Mode, more than one parameter at a time can be changed. Until some proficiency at   
					programming is achieved, it is highly recommended that users only change only one parameter at a time and test the change before   
					proceeding to program any additional changes. It is also recommended that users keep a record of the changes made to the scanner.   
					What If I Make A Mistake?   
					Scanning the "Reset All Defaults" bar code for your type of interface will return the scanner to all factory default settings   
					(including any changes made during previous programming sessions).   
					NOTE: (   
					) A pointing finger indicates scanner default settings throughout the following menus.   
					% 
					Page 13   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Symbology Selection   
					Start/End   
					Program   
					Menu   
					ZZ   
					A0   
					A2   
					A3   
					A4   
					A5   
					A6   
					A7   
					A9   
					AB   
					J0   
					[[   
					B1   
					B3   
					B!   
					B5   
					B6   
					B7   
					B8   
					B:   
					BC   
					K1   
					K2   
					Read all codes   
					% 
					Code 39   
					only   
					Codabar   
					only   
					IATA only   
					Code 93   
					only   
					Code 128   
					only   
					MSI/Plessey   
					only   
					Telepen   
					only   
					Matrix 2of5   
					only   
					All UPC and   
					EAN only   
					UPC   
					only   
					J1   
					CONTINUED ON NEXT PAGE...   
					Page 14   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Symbology Selection (continued)   
					Start/End   
					Program   
					Menu   
					ZZ   
					J2   
					J3   
					J4   
					J5   
					J6   
					J7   
					J8   
					JD   
					[[   
					K3   
					K!   
					K5   
					K6   
					K7   
					K8   
					K9   
					KE   
					UPC+2   
					only   
					UPC+5   
					only   
					EAN   
					only   
					EAN+2   
					only   
					EAN+5   
					only   
					Industrial   
					2of5   
					only   
					Interleaved   
					2of5   
					only   
					Trioptics   
					only   
					These options do not influence the reading of the menu labels. The required bar code types can be selected by enabling a single   
					readable code only and enabling a single readable code only and enabling readable codes. It is strongly recommended that only the   
					required codes be selected.   
					Page 15   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Symbology Additions   
					If scanner will not be used to read all symbologies (default setting), speed operation by using this menu to add only the specific   
					symbologies being used (add only the symbologies that are required).   
					Start/End   
					Program   
					Menu   
					ZZ   
					[[   
					Disable all   
					B0   
					C1   
					Enable   
					Code 39   
					B2   
					C3   
					Enable   
					Codabar   
					B3   
					C!   
					Enable   
					IATA   
					B4   
					C5   
					Enable   
					Code 93   
					B5   
					C6   
					Enable   
					Code 128   
					B6   
					C7   
					Enable   
					MSI/Plessey   
					B7   
					C8   
					Enable   
					Telepen   
					B9   
					C:   
					Enable   
					Trioptics   
					JZ   
					K[   
					Enable   
					UPC   
					R1   
					S2   
					Enable   
					UPC+2   
					R2   
					S3   
					Enable   
					UPC+5   
					R3   
					S!   
					CONTINUED ON NEXT PAGE...   
					Page 16   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Symbology Additions (continued)   
					Start/End   
					Program   
					Menu   
					ZZ   
					R4   
					R5   
					R6   
					R7   
					R8   
					[[   
					S5   
					S6   
					S7   
					S8   
					S9   
					Enable   
					EAN   
					Enable   
					EAN+2   
					Enable   
					EAN+5   
					Enable   
					Industrial   
					2of5   
					Enable   
					Interleaved   
					2of5   
					Page 17   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
				 
			 
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Setting the Number of   
					Characters to be Scanned   
					Start/End   
					Program   
					Menu   
					ZZ   
					[[   
					I1   
					I2   
					IL   
					IM   
					IN   
					Fixed length   
					OFF   
					all codes   
					H0   
					H1   
					% 
					Fixed length   
					ON   
					all codes   
					Fixed length   
					ON   
					selected codes   
					HK   
					HL   
					HM   
					Min. length   
					selected codes   
					Max. length   
					selected codes   
					Setting Code Specific Options - Options for specific codes may be configured affecting:   
					* 
					* 
					Enabling and disabling code variants and translations.   
					Data verification such as by mean of a check digit calculation. A check digit has a value that can be calculated from   
					the other data characters and is usually the last data character in a bar code.   
					* 
					Pre-editing of the data string such as removing the check digit and/or ST/SP characters.   
					The more common options are described here.   
					Check CD - Enables the check digit calculation. If the calculated check digit does not correspond to the check digit in the bar   
					code, then the bar code is ignored. The use of a check digit greatly improves the security of a bar code.   
					Do Not Check CD - Disables the check digit calculation. This option is required when the bar codes do not contain a check digit   
					or contain an invalid check digit.   
					Transmit CD - Enables the transmission of the check digit together with the data characters. If the check digit calculation is   
					disabled, the reader cannot differentiate anymore between a (valid) check digit and a data character. It will therefore transmit all   
					data characters of the label, including what could constitute a check digit.   
					Do Not Transmit CD - Disables the transmission of the check digit. If the check digit calculation is disabled, the reader cannot   
					differentiate between a (valid) check digit and a data character. It will therefore transmit all data characters of the able, excluding   
					the character that could constitute the check digit for the type of bar code.   
					Transmit ST/SP - Enables the transmission of the start and stop characters of a bar code.   
					Do Not Transmit ST/SP - Disables the transmission of the start and stop characters of a bar code.   
					Page 18   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					UPC-A/E Settings   
					Options for UPC-A and UPC-E bar codes.   
					NOTE: Abbreviations: Xmit = transmit; CD = Check digit; CC = Country code   
					Start/End   
					Program   
					Menu   
					ZZ   
					[[   
					UPC-A   
					as EAN13   
					w/ CD   
					E2   
					F3   
					(13 digits)   
					UPC-A   
					% 
					% 
					w/ CD   
					(12 digits)   
					E3   
					F!   
					UPC-A   
					w/ CD   
					(12 digits)   
					E4   
					F5   
					UPC-A   
					w/o CD   
					(11 digits)   
					E5   
					F6   
					UPC-E   
					w/ CC & CD   
					(8 digits)   
					E6   
					F7   
					UPC-E   
					w/o CC,   
					w/ CD   
					(7 digits)   
					E7   
					F8   
					UPC-E   
					w/ CC,   
					w/o CD   
					(7 digits)   
					UPC-E   
					E8   
					F9   
					w/o CC & CD   
					(6 digits)   
					E9   
					F:   
					Xmit UPC-E   
					as UPC-A   
					w/ CD   
					6P   
					7Q   
					(8 digits)   
					Do not   
					xmit UPC-E   
					as UPC-A   
					w/o CD   
					(7 digits)   
					6Q   
					% 
					7R   
					Page 19   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
				 
			 
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					UPC Settings (continued)   
					Options for UPC-A - The UPC-A symbology is a fixed length symbology encoding 11 data digits, a check digit and non printable   
					start/stop characters. Supported characters are numeric digits 1 to 9.   
					An optional leading zero can be transmitted which, together with the data and the check digit, forms a 13 digit field providing   
					compatibility with the EAN-13 format.   
					String format:   
					Leading   
					0 
					data   
					(11 digits)   
					check   
					digit   
					UPC-A add-on 2/add-on 5 - The UPC-A symbology as described above can be succeeded by an additional 2 or 5 digit UPC-A   
					code.   
					String format:   
					Leading   
					0 
					data   
					(11 digits)   
					check   
					digit   
					add-on   
					2 or 5   
					Options for UPC-A   
					* 
					* 
					Disable transmission of the leading zero   
					Disable transmission of the check digit   
					Options for UPC-E - The UPC-E symbology is a fixed length symbology encoding 6 data digits, a check digits and non printable   
					start/stop characters. Supported characters include numeric digits 0 to 9. An optional leading zero can be transmitted which,   
					together with the data and the check digit, forms an 8 digit field providing a compatibility with the EAN-8 format.   
					String format:   
					Leading   
					0 
					data   
					(6 digits)   
					check   
					digit   
					UPC-E add-on 2/add-on 5 - The UPC-E symbology as described above can be succeeded by an additional 2 or 5 digit UPC-A   
					code.   
					String format:   
					Leading   
					0 
					data   
					(6 digits)   
					check   
					digit   
					add-on   
					2 or 5   
					Options for UPC-E   
					* 
					* 
					* 
					Enable transmission of the leading zero   
					Disable transmission of the check digit   
					Transmit UPC-E as UPC-A   
					Page 20   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					EAN-13 and EAN-8 Settings   
					Start/End   
					Program   
					Menu   
					ZZ   
					[[   
					7L   
					7K   
					7J   
					7I   
					JC   
					JB   
					JL   
					IO   
					IP   
					5W   
					EAN-13   
					transmit CD   
					6K   
					6J   
					% 
					% 
					% 
					EAN-13   
					do not   
					transmit CD   
					EAN-8   
					transmit CD   
					6I   
					EAN-8   
					do not   
					transmit CD   
					6H   
					IB   
					Disable   
					ISBN   
					translation   
					Enable   
					ISBN   
					translation   
					IA   
					IK   
					HN   
					HO   
					4V   
					Enable   
					ISBN if   
					possible   
					Disable   
					ISSN   
					translation   
					% 
					Enable   
					ISSN   
					translation   
					Enable   
					ISSN if   
					possible   
					Page 21   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
				 
			 
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					EAN-13 and EAN-8 Settings   
					EAN-13 is a fixed length symbology encoding 12 data digits, a check digit and non printable start/stop characters. Supported   
					characters are numeric digits 0 to 9. The data may be translated into ISBN or ISSN format.   
					String format:   
					data   
					(12 digits)   
					check   
					digit   
					EAN-13 add-on 2/add-on 5 - The EAN-13 symbology as described above can be succeeded by an additional 2 or 5 digit UPC-A   
					code.   
					String format:   
					data   
					(12 digits)   
					check   
					digit   
					add-on   
					2 or 5   
					EAN-8 is a fixed length symbology encoding 7 data digits, a check digit and non printable start/stop characters. Supported   
					characters are numeric digits 0 to 9.   
					String format:   
					data   
					(7 digits)   
					check   
					digit   
					EAN-8 add-on 2/add-on 5 - The EAN-8 symbology as described above can be succeeded by an additional 2 or 5 digit UPC-A   
					code.   
					String format:   
					data   
					(7 digits)   
					check   
					digit   
					add-on   
					2 or 5   
					Options for EAN   
					* 
					* 
					Disable transmission of the check digit   
					Enable ISBN or ISSN translation   
					Enable ISBN or ISSN translation - If this option is enabled, an EAN-13 label is verified for the correct format and transmitted as a   
					10 digit ISBN number or 8 digit ISSN number.   
					Page 22   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Code 39 Settings   
					Start/End   
					Program   
					Menu   
					ZZ   
					C0   
					C1   
					D0   
					D1   
					D4   
					D5   
					D8   
					D9   
					+K   
					+L   
					+M   
					8D   
					8E   
					[[   
					D1   
					D2   
					E1   
					E2   
					E5   
					E6   
					E9   
					E:   
					,L   
					,M   
					,N   
					9E   
					9F   
					Check CD   
					Do not   
					check CD   
					% 
					% 
					Xmit ST/SP   
					Do not   
					xmit ST/SP   
					Full ASCII   
					Normal   
					Code 39   
					% 
					% 
					Do not   
					xmit CD   
					Xmit CD   
					Full ASCII   
					Code 39 if   
					possible   
					Enable   
					concat-enation   
					Disable   
					concat-enation   
					% 
					Minimum   
					3 digits   
					Minimum   
					1 digit   
					CONTINUED ON NEXT PAGE...   
					Page 23   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
				 
			 
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Code 39 Settings (continued)   
					Code 39 is a variable length symbology with an optional check digit ("CD") and printable start/stop ("ST/SP") characters. The   
					following characters are supported:   
					• 
					• 
					• 
					• 
					Numeric characters 0 to 9   
					Alpha characters capital A to Z   
					Special characters - $ / + % and SPACE   
					Start/stop character is *   
					The checksum is calculated as the sum modulo 43 of the numerical value of the data characters.   
					In full ASCII mode, all 128 ASCII characters are supported. This is done by combining one of the characters +, %, $ or / with one   
					of the alpha characters (A to Z).   
					String format:   
					start   
					char.   
					data (0 or   
					more characters)   
					check stop   
					digit char.   
					Options for Code 39:   
					* 
					* 
					* 
					* 
					* 
					* 
					* 
					Enable full ASCII conversion   
					Enable Italian Pharmaceutical conversion   
					Enable check digit   
					Disable transmission of the check digit   
					Enable transmission of start/stop   
					Enable leading A for Italian Pharmaceutical   
					Selection of the minimum number of data characters   
					Normal Code 39 - In this mode the decoded data characters are transmitted without further translation.   
					Full ASCII Code 39 - In this mode the decoded data characters are translated to full ASCII Code 39.   
					Full ASCII Code 39 if possible - In this mode the decoded data characters are translated to full ASCII code 39. Invalid   
					combinations are not translated and are transmitted as is.   
					Concatenation - If a Code 39 bar code contains a leading space, the data is stored into the reader's buffer without the leading   
					space. As soon as a Code 39 bar code is read without a leading space, the data is appended to the reader's buffer and the entire   
					buffer is transmitted and cleared for new data. In case a non Code 39 bar code bar is transmitted and the buffer is cleared. The   
					buffer size is reader dependant.   
					Page 24   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Codabar Settings   
					Start/End   
					Program   
					Menu   
					ZZ   
					F0   
					F1   
					F2   
					F3   
					F4   
					H3   
					H4   
					H5   
					H6   
					H7   
					H8   
					H9   
					[[   
					G1   
					G2   
					G3   
					G!   
					G5   
					I!   
					I5   
					I6   
					I7   
					I8   
					I9   
					I:/   
					Do not   
					transmit   
					start/stop   
					% 
					Transmit   
					start/stop as   
					ABCD/TN*E   
					Transmit   
					start/stop as   
					abcd/tn*e   
					Transmit   
					start/stop as   
					ABCD/ABCD   
					Transmit   
					start/stop as   
					abcd/abcd   
					Enable   
					Codabar,   
					ABC and CX   
					Enable only   
					ABC code   
					Enable only   
					CX code   
					Check CD   
					Do not   
					check CD   
					% 
					% 
					Transmit   
					CD   
					Do not   
					transmit CD   
					CONTINUED ON NEXT PAGE...   
					Page 25   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Codabar Settings (continued)   
					Start/End   
					Program   
					Menu   
					ZZ   
					HA   
					HB   
					HC   
					HD   
					HE   
					HF   
					HH   
					HI   
					[[   
					IB   
					IC   
					ID   
					IE   
					IF   
					IG   
					II   
					IJ   
					Enable   
					Codabar   
					normal mode   
					only   
					% 
					Min. data   
					3 chars.   
					Min. data   
					1 char.   
					Enable space   
					insertion   
					Disable space   
					insertion   
					% 
					% 
					% 
					Min. data   
					5 chars.   
					Enable   
					interchar. gap   
					check   
					Disable   
					interchar. gap   
					check   
					Codabar Settings   
					Codabar (NW7) is a variable length symbology with an optional check digit and printable start/stop characters. Supported   
					characters include:   
					* 
					* 
					* 
					Numeric digits 0 to 9   
					special characters - $ : / , +   
					start/stop characters are A, B, C or D   
					The checksum is calculated as the sum modulo 16 of the numerical values of all data characters.   
					String format:   
					start   
					char.   
					data (1 or   
					more chars.)   
					check   
					digit   
					stop   
					char.   
					CONTINUED ON NEXT PAGE...   
					Page 26   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
				 
			 
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Codabar Settings (continued)   
					ABC-Code - The ABC code is an acronym for American Blood Commission. The code consists of two bar codes which are   
					decoded in one read cycle. the code is concatenated when the stop character of the first bar code and the start character of the   
					second bar code is a D. These two D's are not transmitted.   
					String format:   
					start data (1+ check data (1+ check stop   
					char.   
					chars.)   
					digit   
					chars.)   
					digit char.   
					CX-Code - The CX-Code consists of two are codes which are decoded in one read cycle. The code is concatenated when the stop   
					character of the first bar code is a C, and the start character of the second bar code is a B. The B and C characters are not   
					transmitted.   
					String format:   
					start data (1+ check data (1+ check stop   
					char.   
					chars.)   
					digit   
					chars.)   
					digit char.   
					Options for Codabar:   
					* 
					* 
					* 
					* 
					* 
					* 
					* 
					* 
					* 
					Enable ABC code concatenation.   
					Enable CD code concatenation.   
					Enable check digit check.   
					Disable transmission of the check digit.   
					Disable transmission of start/stop.   
					Selection of start/stop character translation.   
					Selection of minimum number of data characters.   
					Enable library space (CLSI) insertion.   
					Space insertion - This option inserts spaces in position 2, 7 and 13 of the data string for use in library systems.   
					ST/SP translation - This option enables the translation and transmission of the start and stop characters. Thus, if the option   
					ST/SP: abcd/tn*e is chosen, the start character is converted to lower case, e.g. from A, B, C or D to a, b, c or d, respectively), and   
					the stop character is converted from A, B, C or D to t, n, * or e, respectively.   
					Minimum data characters - Codabar labels are checked for a minimum of 1, 3 or 5 characters as set by the user. If the number of   
					characters in the label is shorter than the minimum selected, the label will be rejected. If the fixed length option is used for   
					Codabar type labels, then such labels will additionally be checked for fixed length. This option will no longer be supported in   
					future software releases.   
					Intercharacter gap check - This option enables the reading of Codabar labels with a large or irregular gap between characters.   
					Page 27   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					2of5 Settings   
					Start/End   
					Program   
					Menu   
					ZZ   
					E0   
					E1   
					G0   
					G1   
					GE   
					GF   
					GI   
					[[   
					F1   
					F2   
					H1   
					H2   
					HF   
					HG   
					GJ   
					GK   
					HL   
					Transmit   
					CD   
					% 
					% 
					Do not   
					transmit CD   
					Do not   
					check CD   
					Check CD   
					Min. data   
					1 char.   
					Min. data   
					3 chars.   
					Min. data   
					5 chars.   
					% 
					% 
					Enable space   
					check for   
					Industrial 2of5   
					GJ   
					GK   
					Disable space   
					check for   
					Industrial 2of5   
					CONTINUED ON NEXT PAGE...   
					Page 28   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
				 
			 
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					2of5 Settings (continued)   
					Code 2of5 is a variable length symbology with an optional check digit and non printable start and stop character. Supported   
					characters include numeric digits 0 to 9.   
					The checksum is calculated as the sum modulo 10 of the numerical values of all the data characters. The following 2of5 codes are   
					supported.   
					Industrial 2of5 (D 2of5) - This symbology encodes a pair of digits in each symbol, the number of digits are therefore always an   
					even number. Information is carried in the bars and spaces. The start and stop pattern in not unique inside the code. It is therefore   
					essential to use the fixed length option to prevent partial reads.   
					Matrix 2of5 - This symbology encodes 1 digit in each character, the number of digits can therefore be an odd or an even number.   
					Information is carried in the bars and spaces.   
					String format - Industrial, Interleaved or Matrix 2of5:   
					leading   
					zero   
					data (1 or   
					more digits)   
					check   
					digit   
					Options for Code 2of5:   
					* 
					* 
					* 
					* 
					* 
					* 
					Disable transmission of the check digit   
					Enable check digit check   
					Selection of the minimum number of data characters   
					Disable space check for industrial 2of5   
					Transmit S Code as Interleaved 2of5   
					Minimum data characters - Code 2of5 are checked for a minimum of 1, 3 or 5 characters as set by the user. If the number of   
					characters in the label is less than the number set, the label will be rejected. If the fixed length option is used for a Code 2of5 type   
					label, then such label will also be checked for fixed length.   
					Intercharacter gap check - This option enables the reading of Industrial 2of5 labels with a large or irregular spacing.   
					Page 29   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
				 
			 
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					MSI/Plessey Settings   
					Start/End   
					Program   
					Menu   
					ZZ   
					4A   
					4B   
					4C   
					4D   
					4E   
					4F   
					[[   
					5B   
					5C   
					%D   
					5E   
					5F   
					5G   
					5H   
					5S   
					Do not   
					check CD   
					Check 1 CD =   
					Mod 10   
					% 
					% 
					Check 2 CD's   
					= Mod 10   
					/Mod 10   
					Check 2 CD's   
					= Mod 10   
					/Mod 11   
					Transmit CD1   
					Transmit CD1   
					and CD2   
					Do not   
					transmit CD   
					4G   
					Check 2 CD's   
					= Mod 11   
					/Mod 10   
					4R   
					MSI Plessey is a variable length symbology with one or two optional check digit calculations CD1 and CD2 and non printable   
					start/stop characters. Supported characters include numeric digits 0 through 9.   
					The checksum is calculated as the sum modulo 10 or 11 of the data characters. The checksum CD2 is calculated as the sum   
					modulo 10 or 11 of the data characters and CD1.   
					String format:   
					data (1 to   
					CD1 CD2   
					13 digits)   
					Options for MSI/Plessey:   
					* 
					* 
					* 
					Disable check digit check.   
					Selection of the check digit calculation.   
					Selection of the number of check digits to be transmitted.   
					Check digit - If the check digit calculation is required, then the appropriate calculation method must be selected.   
					Do not transmit CD - The character positions CD1 and CD2 are not transmitted.   
					Transmit CD1 - The character position CD2 is not transmitted.   
					Transmit CD1 and CD2 - All characters in the label are transmitted.   
					Page 30   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
				 
			 
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Code 128, EAN 128 Settings   
					Start/End   
					Program   
					Menu   
					ZZ   
					[[   
					KG   
					NP   
					NQ   
					PG   
					PH   
					Enable   
					EAN 128   
					only   
					JF   
					Enable FNC2   
					concat-enation   
					MO   
					MP   
					OF   
					Disable FNC2   
					concat-enation   
					% 
					% 
					Disable   
					EAN 128   
					Enable   
					EAN 128   
					if possible   
					OG   
					Code 128 is a variable length symbology with a mandatory check digit and non-printable start/stop characters. Supported   
					characters include:   
					* 
					* 
					* 
					* 
					* 
					All 128 ASCII characters;   
					4 non data function characters;   
					4 code set selection characters;   
					3 start characters; and   
					1 stop character.   
					The check is calculated as the sum modulo 103 of the start character and the weighted values of the data and special characters.   
					String format:   
					data (1 or more characters)   
					EAN 128 - In this mode, the Code 128 data is translated to the EAN 128 format. EAN 128 data starts with the FNC1 character and   
					separates 2 data fields with the FNC1 character. The first FNC1 character is translated to ]C1, and the second FNC1 character is   
					translated to ASCII GS (hex 1D) character.   
					String format:   
					data   
					characters   
					data   
					characters   
					]C1   
					<GS>   
					Enable EAN 128 only - In the mode, the decoded data characters are translated to the EAN 128 format. If the data does not   
					comply with the EAJ 128 format, then the label is rejected.   
					Enable EAN 128 if possible - In this mode, the decoded data characters are translated to the EAN 128 format. If the data does not   
					comply with the EAN 128 format, then the label is transmitted as Code 128.   
					FNC2 Concatenation - If a Code 128 bar code contains a leading FNC2 character, the data is stored into the reader's buffer. As   
					soon as a Code 128 bar code is read without a leading FNC2 character, the data is appended to the reader's buffer and the entire   
					buffer is transmitted and cleared for new data. In case a non Code 128 bar code is read, the data in the non-Code 128 bar code is   
					transmitted and the buffer is cleared. The buffer size is reader dependent.   
					Page 31   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
				 
			 
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					IATA Settings   
					Start/End   
					Program   
					Menu   
					ZZ   
					4H   
					4I   
					[[   
					5I   
					Do not   
					check CD   
					% 
					Check S/N   
					only   
					5J   
					5K   
					5L   
					5M   
					5N   
					Check CPN,   
					S/N   
					4J   
					Check CPN,   
					airline and   
					S/N   
					4K   
					4L   
					4M   
					Transmit CD   
					% 
					Do not   
					transmit CD   
					IATA is a variable length symbology with an optional check digit and non printable start/stop characters. Supported characters   
					include numeric digits 0 through 9.   
					The checksum is calculated as the modulo seven of the data string. IATA is acronym for International Air Transport Association.   
					String format - A possible format of IATA is as follows:   
					Code   
					Description Coupon Airline Code Form Code Serial Number Check Digit   
					Digits   
					15   
					CPN   
					AC   
					FC   
					SN   
					CD   
					1 
					3 
					2 
					8 
					Options for IATA:   
					* 
					* 
					* 
					Enable check digit check.   
					Selection of the check digit calculation.   
					Disable transmission of the check digit.   
					Check digit - If the check digit calculation is required, then the appropriate calculation method must be selected.   
					Page 32   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Telepen Settings   
					Start/End   
					Program   
					Menu   
					ZZ   
					D2   
					D3   
					[[   
					E3   
					E!   
					Numeric   
					mode   
					% 
					ASCII mode   
					Telepen is a variable length symbology with a check digit and non printable start/stop characters. Supported characters include   
					numeric digits 00 through 99 in numeric mode, and all 128 ASCII characters in full ASCII mode.   
					The check digit calculation is derived from the sum of all data characters modulo 127. The check digit cannot be transmitted.   
					String format:   
					Data   
					(1 to 32 characters)   
					Options for Telepen:   
					* 
					Selection of full ASCII mode.   
					Page 33   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Case Conversion   
					Start/End   
					Program   
					Menu   
					ZZ   
					YZ   
					[[   
					Z[   
					ZX   
					ZY   
					ZZ   
					No case   
					conversion   
					% 
					Convert to   
					upper case   
					YW   
					YX   
					YY   
					Convert to   
					lower case   
					Exchange case   
					String Options - This section describes the alterations which can be made to the format of the transmitted data string. Options   
					available are:   
					* 
					* 
					* 
					* 
					* 
					Case conversion   
					Transmission of a code identifier   
					Transmission of the code length   
					Transmission of a prefix   
					Transmission of a suffix   
					The prefix and/or suffix may include a code identifier and/or the code length.   
					String format:   
					bar code   
					data   
					suffix   
					prefix   
					Case conversion - The bar code may be converted to either lower of upper case or the case my be exchanged. These options may   
					be used if the user of a wedge has a preference to leave, for instance, the CAPSLOCK ON or if the host required upper case   
					characters only.   
					Page 34   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Setting a Prefix or Suffix   
					A Prefix and Suffix consisting of a maximum 4 direct input entries each may be included in front and at the end of the string,   
					respectively.   
					The following steps are used to establish a Prefix or Suffix that will be transmitted with the bar code data.   
					1)   
					2)   
					3)   
					4)   
					Scan Start/End Program Menu to enter programming mode.   
					Scan the bar code representing the desired symbology you wish to add a Prefix or Suffix to.   
					Scan the character(s) that comprise the Prefix or Suffix. Up to 4 numbers, letters or control characters may be used.   
					Scan Start/End Program Menu to exit programming mode.   
					Prefix Settings   
					Start/End   
					Program   
					Menu   
					ZZ   
					GL   
					I8   
					[[   
					HM   
					J9   
					M9   
					/N1   
					N2   
					N!   
					N!   
					N5   
					N6   
					N7   
					Matrix 2of5   
					IATA   
					Telepen   
					L8   
					UPC-A   
					+ add-on   
					M0   
					M1   
					M2   
					M3   
					M4   
					M5   
					M6   
					UPC-E   
					+ add-on   
					EAN-13   
					+ add-on   
					EAN-8   
					+ add-on   
					Code 39   
					Codabar   
					Industrial 2of5   
					CONTINUED ON NEXT PAGE...   
					Page 35   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Prefix Settings (continued)   
					Start/End   
					Program   
					Menu   
					ZZ   
					M7   
					M8   
					M9   
					N0   
					[[   
					N8   
					N9   
					N:   
					O1   
					O2   
					O3   
					O!   
					O5   
					SZ   
					NH   
					N[   
					Interleaved   
					2of5   
					Code 93   
					Code 128   
					MSI/Plessey   
					UPC-A   
					N1   
					UPC-E   
					N2   
					EAN-13   
					EAN-8   
					N3   
					N4   
					All codes   
					RY   
					MG   
					MZ   
					Clear all   
					prefixes   
					Preamble   
					Page 36   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Suffix Settings   
					Start/End   
					Program   
					Menu   
					ZZ   
					GM   
					I9   
					[[   
					HN   
					J:   
					M:   
					O6   
					O7   
					O8   
					O9   
					O:   
					P1   
					P2   
					P3   
					P!   
					P5   
					P6   
					Matrix 2of5   
					IATA   
					Telepen   
					MSI/Plessey   
					UPC-A   
					L9   
					N5   
					N6   
					N7   
					N8   
					N9   
					O0   
					O1   
					O2   
					O3   
					O4   
					O5   
					UPC-E   
					EAN-13   
					EAN-8   
					UPC-A   
					+ add-on   
					UPC-E   
					+ add-on   
					EAN-13   
					+ add-on   
					EAN-8   
					+ add-on   
					Code 39   
					Codabar   
					CONTINUED ON NEXT PAGE...   
					Page 37   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Suffix Settings (continued)   
					Start/End   
					Program   
					Menu   
					ZZ   
					O6   
					O7   
					O8   
					O9   
					PR   
					PS   
					RZ   
					[[   
					P7   
					P8   
					P9   
					P:   
					QS   
					QT   
					S[   
					Industrial   
					2of5   
					Interleaved   
					2of5   
					Code 93   
					Code 128   
					Clear all   
					suffixes   
					Postamble   
					All Codes   
					Page 38   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Direct Input Keyboard Keys   
					Start/End   
					Program   
					Menu   
					ZZ   
					[[   
					9K   
					9L   
					9M   
					9N   
					9O   
					9P   
					9Q   
					9R   
					9S   
					9T   
					9U   
					9V   
					:Y   
					8I   
					F1   
					F2   
					8J   
					8K   
					8L   
					8M   
					8N   
					8O   
					8P   
					F3   
					F4   
					F5   
					F6   
					F7   
					F8   
					8Q   
					8R   
					8S   
					F9   
					F10   
					F11   
					F12   
					Backspace   
					TAB   
					8T   
					8U   
					9X   
					7H   
					CONTINUED ON NEXT PAGE...   
					Page 39   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Direct Input Keyboard Keys (continued)   
					Start/End   
					Program   
					Menu   
					ZZ   
					7I   
					[[   
					8J   
					8R   
					8S   
					8E   
					8K   
					8L   
					8M   
					8N   
					8O   
					8U   
					WR   
					WS   
					WT   
					8P   
					Carriage   
					return   
					% 
					Enter   
					(numeric pad)   
					7Q   
					7R   
					7S   
					Enter make   
					(alpha pad)   
					Enter make   
					and break   
					(alpha pad)   
					ESC   
					7J   
					Arrow down   
					Arrow up   
					Arrow right   
					Arrow left   
					<DEL>   
					7K   
					7L   
					7M   
					7N   
					7T   
					VQ   
					VR   
					VS   
					7O   
					<INSERT>   
					<HOME>   
					<END>   
					Page up   
					CONTINUED ON NEXT PAGE...   
					Page 40   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Direct Input Keyboard Keys (continued)   
					Start/End   
					Program   
					Menu   
					ZZ   
					7P   
					[[   
					8Q   
					8V   
					8X   
					8Z   
					8W   
					8Y   
					8[   
					:T   
					Page down   
					Left   
					<Shift>   
					7U   
					7W   
					7Y   
					7V   
					7X   
					7Z   
					9S   
					Left   
					<Ctrl>   
					Left   
					<Alt>   
					Right   
					<Shift>   
					Right   
					<Ctrl>   
					Right   
					<Alt>   
					CAPSLOCK   
					Page 41   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Direct Input Characters   
					Start/End   
					Program   
					Menu   
					ZZ   
					5A   
					5B   
					5C   
					5D   
					5E   
					5F   
					5G   
					5H   
					5I   
					[[   
					6B   
					6C   
					6D   
					6E   
					6F   
					6G   
					6H   
					6I   
					6J   
					6K   
					6L   
					6M   
					6N   
					6O   
					<SPACE>   
					! 
					" 
					# 
					$ 
					% 
					& 
					' 
					( 
					) 
					5J   
					* 
					+ 
					, 
					5K   
					5L   
					5M   
					5N   
					- 
					CONTINUED ON NEXT PAGE...   
					Page 42   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Direct Input Characters (continued)   
					Start/End   
					Program   
					Menu   
					ZZ   
					5O   
					5P   
					[[   
					6P   
					6Q   
					7B   
					7C   
					7D   
					7E   
					7F   
					7G   
					7H   
					8B   
					8C   
					8D   
					8E   
					8F   
					. 
					/ 
					: 
					6A   
					6B   
					6C   
					6D   
					6E   
					6F   
					; 
					< 
					= 
					> 
					? 
					@ 
					[ 
					6G   
					7A   
					7B   
					7C   
					7D   
					7E   
					\ 
					] 
					^ 
					_ 
					CONTINUED ON NEXT PAGE...   
					Page 43   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Direct Input Characters (continued)   
					Start/End   
					Program   
					Menu   
					ZZ   
					7F   
					[[   
					8G   
					:U   
					:V   
					:W   
					:X   
					` 
					{ 
					| 
					9T   
					9U   
					9V   
					9W   
					} 
					~ 
					CONTINUED ON NEXT PAGE...   
					Page 44   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Direct Input Characters (continued)   
					Start/End   
					Program   
					Menu   
					ZZ   
					Q0   
					Q1   
					Q2   
					Q3   
					Q4   
					Q5   
					Q6   
					Q7   
					Q8   
					Q9   
					0A   
					0B   
					0C   
					[[   
					R1   
					R2   
					R3   
					R!   
					R5   
					R6   
					R7   
					R8   
					R9   
					R:   
					1B   
					1C   
					1D   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					9 
					A 
					B 
					C 
					CONTINUED ON NEXT PAGE...   
					Page 45   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Direct Input Characters (continued)   
					Start/End   
					Program   
					Menu   
					ZZ   
					0D   
					0E   
					0F   
					0G   
					0H   
					0I   
					[[   
					1E   
					1F   
					1G   
					1H   
					1I   
					1J   
					1K   
					1L   
					1M   
					1N   
					1O   
					1P   
					1Q   
					1R   
					D 
					E 
					F 
					G 
					H 
					I 
					J 
					0J   
					K 
					L 
					M 
					N 
					O 
					P 
					0K   
					0L   
					0M   
					0N   
					0O   
					0P   
					0Q   
					Q 
					CONTINUED ON NEXT PAGE...   
					Page 46   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Direct Input Characters (continued)   
					Start/End   
					Program   
					Menu   
					ZZ   
					0R   
					0S   
					[[   
					1S   
					1T   
					1U   
					1V   
					1W   
					1X   
					1Y   
					1Z   
					1[   
					%B   
					%C   
					%D   
					%E   
					%F   
					R 
					S 
					T 
					U 
					V 
					W 
					X 
					Y 
					Z 
					a 
					0T   
					0U   
					0V   
					0W   
					0X   
					0Y   
					0Z   
					$A   
					$B   
					$C   
					$D   
					$E   
					b 
					c 
					d 
					e 
					CONTINUED ON NEXT PAGE...   
					Page 47   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Direct Input Characters (continued)   
					Start/End   
					Program   
					Menu   
					ZZ   
					$F   
					$G   
					$H   
					$I   
					[[   
					%G   
					%H   
					%I   
					%J   
					%K   
					%L   
					%M   
					%N   
					%O   
					%P   
					%Q/   
					%R   
					%S   
					%T   
					f 
					g 
					h 
					i 
					j 
					$J   
					k 
					l 
					$K   
					$L   
					$M   
					$N   
					$O   
					$P   
					$Q   
					$R   
					$S   
					m 
					n 
					o 
					p 
					q 
					r 
					s 
					CONTINUED ON NEXT PAGE...   
					Page 48   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Direct Input Characters (continued)   
					Start/End   
					Program   
					Menu   
					ZZ   
					$T   
					[[   
					%U   
					%V   
					%W   
					%X   
					%Y   
					%Z   
					%[   
					t 
					u 
					v 
					w 
					x 
					y 
					z 
					$U   
					$V   
					$W   
					$X   
					$Y   
					$Z   
					Page 49   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Direct Input Control Characters   
					Start/End   
					Program   
					Menu   
					ZZ   
					9G   
					1A   
					1B   
					1C   
					1D   
					1E   
					1F   
					1G   
					1H   
					1I   
					[[   
					:H   
					2B   
					2C   
					2D   
					2E   
					2F   
					2G   
					2H   
					2I   
					2J   
					2K   
					2L   
					2M   
					2N   
					^@(NULL)   
					^A(SOH)   
					^B(STX)   
					^C(ETX)   
					^D(EOT)   
					^E(ENQ)   
					^F(ACK)   
					^G(BEL)   
					^H(BS)   
					^I(HT)   
					^J(LF)   
					1J   
					^K(VT)   
					1K   
					1L   
					1M   
					^L(FF)   
					^M(CR)   
					CONTINUED ON NEXT PAGE...   
					Page 50   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Direct Input Control Characters (continued)   
					Start/End   
					Program   
					Menu   
					ZZ   
					1N   
					1O   
					1P   
					[[   
					2O   
					2P   
					2Q   
					2R   
					2S   
					2T   
					2U   
					2V   
					2W   
					2X   
					2Y   
					2Z   
					2[   
					:B   
					^N(SO)   
					^O(SI)   
					^P(DLE)   
					^Q(DC1)   
					^R(DC2)   
					^S(DC3)   
					^T(DC4)   
					^U(NAK)   
					^V(SYN)   
					^W(ETB)   
					^X(CAN)   
					^Y(EM)   
					^Z(SUB)   
					^[(ESC)   
					1Q   
					1R   
					1S   
					1T   
					1U   
					1V   
					1W   
					1X   
					1Y   
					1Z   
					9A   
					CONTINUED ON NEXT PAGE...   
					Page 51   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Direct Input Control Characters (continued)   
					Start/End   
					Program   
					Menu   
					ZZ   
					9B   
					9C   
					9D   
					9E   
					9F   
					[[   
					:C   
					:D   
					:E   
					:F   
					:G   
					^\(FS)   
					^](GS)   
					^^(RS)   
					^_(US)   
					DEL   
					(ASCII 127)   
					Direct Input Code ID/Length   
					Start/End   
					Program   
					Menu   
					ZZ   
					[[   
					%3   
					%!   
					Code   
					identification   
					$2   
					Code length   
					$3   
					Page 52   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
				 
			 
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Read Mode Settings   
					Start/End   
					Program   
					Menu   
					ZZ   
					S0   
					[[   
					T1   
					T2   
					T3   
					YB   
					TC   
					YD   
					YE   
					Single   
					read   
					Multiple   
					read   
					S1   
					% 
					% 
					Continuous   
					read   
					S2   
					Add-on   
					wait mode   
					disabled   
					XA   
					XB   
					XC   
					XD   
					Add-on   
					wait mode   
					0.25 sec.   
					Add-on   
					wait mode   
					0.50 sec.   
					Add-on   
					wait mode   
					0.70 sec.   
					Single Read - When a bar code has been decoded, the reader will be turned OFF. The reader must be triggered again to read   
					another label. This option and "Disable trigger" cannot be programmed at the same time.   
					Multiple Read - When a bar code has been decoded, the reader will stay ON for a time as set by "read time settings" or   
					indefinitely if the trigger switch has been disabled. The same label can only be decoded again after the label has not been detected   
					for a number of scans.   
					Continuous Read - The reader will produce as much data as it can decode regardless whether it is the same or not. This mode is   
					mainly used for demonstration and diagnosis.   
					Add-on Wait Mode - Used if UPC/EAN with add-on is enabled. The reader searches within the selected time for a valid add-on   
					code. If a valid add-on code is found, the reader transmits the data immediately. If nothing is found behind the code, the scanner   
					will transmit the data without add-on. If something is found behind the code, the reader ignored the code in case it is not a valid   
					add-on.   
					Page 53   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Trigger Settings   
					Start/End   
					Program   
					Menu   
					ZZ   
					S7   
					S8   
					[[   
					T8   
					T9   
					Disable   
					trigger   
					Enable   
					trigger   
					Disable Trigger - This is applicable to readers which have a trigger switch. When this option is selected, the reader will stay ON   
					all the time.   
					Multiple Read Reset Time   
					Start/End   
					Program   
					Menu   
					ZZ   
					[[   
					50 ms   
					AH   
					BI   
					100 ms   
					AI   
					BJ   
					200 ms   
					AJ   
					BK   
					300 ms   
					AK   
					BL   
					400 ms   
					AL   
					BM   
					500 ms   
					AM   
					% 
					BN   
					BO   
					600 ms   
					AN   
					Multiple Read Reset Time - This option can be used in conjunction with multiple read mode. It sets the time the reader should be   
					pointed away from the label before it can decode the same label again.   
					Page 54   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Quiet Zone Settings   
					Start/End   
					Program   
					Menu   
					ZZ   
					YN   
					YO   
					YP   
					YQ   
					YR   
					YS   
					YT   
					YU   
					[[   
					ZO   
					ZP   
					ZQ   
					ZR   
					ZS   
					ZE   
					ZU   
					ZV   
					No margin   
					check   
					Margin   
					check 1/7   
					normal   
					Margin   
					check 2/7   
					normal   
					Margin   
					check 3/7   
					normal   
					Margin   
					check 4/7   
					normal   
					Margin   
					check 5/7   
					normal   
					Margin   
					check 6/7   
					normal   
					Margin   
					check   
					normal   
					% 
					With these settings, the reader can decode bar codes that have smaller start and/or end margins than specified for the symbology.   
					These settings may increase the possibility of partial and ghost reads, hence do not use smaller margin checks than necessary.   
					Replace any bar code labels with ones that have the correct start and end margins if possible.   
					Page 55   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Read Time Settings   
					Start/End   
					Program   
					Menu   
					ZZ   
					Y0   
					Y1   
					Y2   
					Y3   
					Y4   
					Y5   
					Y6   
					Y7   
					Y8   
					YL   
					YM   
					[[   
					Z1   
					Z2   
					Z3   
					Z!   
					Z5   
					Z6   
					Z7   
					Z8   
					Z9   
					ZM   
					ZN   
					0 seconds   
					1 second   
					2 seconds   
					3 seconds   
					4 seconds   
					5 seconds   
					6 seconds   
					7 seconds   
					8 seconds   
					% 
					Read time   
					x 10   
					Indefinitely   
					Read Time Settings - the length of the period that the reader is ON after the trigger switch is pressed, or (in multiple or   
					continuous read mode) after a label has been read. Selecting a read time of 0 means that the reader will stay ON as long as the   
					trigger switch is being pressed. Selecting a read time for readers without a trigger switch, or when the trigger switch is disabled,   
					has no effect.   
					Page 56   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Redundant Decoding Settings   
					Start/End   
					Program   
					Menu   
					ZZ   
					X0   
					X1   
					X2   
					X3   
					[[   
					Y1   
					Y2   
					Y3   
					Y!   
					No   
					redundancy   
					Two times   
					redundant   
					% 
					Three times   
					redundant   
					Four times   
					redundant   
					Redundancy Settings - This is the number of times that a label must be correctly decoded before it is transmitted. Selecting a   
					higher redundancy count makes reading slower, but it reduces the probability of reading errors, especially when labels of poor   
					definition are used.   
					Positive and Negative Bar Codes   
					Start/End   
					Program   
					Menu   
					ZZ   
					[[   
					Positive   
					bar codes   
					V2   
					W3   
					Both positive   
					and negative   
					V4   
					% 
					W5   
					Positive and Negative Bar Codes - Usually bar codes are printed black on white, but sometime white on black. These labels are   
					bar codes   
					called positive and negative, respectively.   
					Page 57   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Buzzer Settings   
					Start/End   
					Program   
					Menu   
					ZZ   
					W8   
					W0   
					W1   
					W2   
					W3   
					W7   
					W4   
					W5   
					W6   
					T0   
					[[   
					X9   
					X1   
					X2   
					X3   
					X!   
					X8   
					X5   
					X6   
					X7   
					U1   
					U2   
					U3   
					U!   
					WZ   
					Enable   
					software   
					buzzer   
					% 
					% 
					Disable   
					buzzer   
					Single tone   
					buzzer   
					High - low   
					buzzer   
					Low - high   
					buzzer   
					Buzzer   
					duration   
					50 msec.   
					Buzzer   
					duration   
					100 msec.   
					Buzzer   
					duration   
					200 msec.   
					% 
					% 
					Buzzer   
					duration   
					400 msec.   
					Buzzer   
					volume   
					maximum   
					Buzzer   
					volume   
					loud   
					T1   
					Buzzer   
					volume   
					normal   
					T2   
					Buzzer   
					volume   
					minimum   
					T3   
					Buzzer before   
					transmission   
					VY   
					% 
					CONTINUED ON NEXT PAGE...   
					Page 58   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
				 
			 
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Buzzer Settings   
					Start/End   
					Program   
					Menu   
					ZZ   
					VZ   
					GD   
					GC   
					[[   
					W[   
					HE   
					HD   
					Buzzer   
					after   
					transmission   
					Disable   
					startup buzzer   
					Enable startup   
					buzzer   
					Buzzer Settings - These options determine the buzzer type, tone, duration and loudness. By default, the buzzer is disabled for   
					Linker type readers.   
					Buzzer Type - The buzzer may be disabled or enabled as either a hardware of software buzzer. Not all readers support both a   
					hardware and software buzzer.   
					Buzzer Tone - If a software buzzer is used, the buzzer tone may be selected.   
					Buzzer Duration and Volume - If a software buzzer is used, a buzzer duration of 50, 100, 200 or 400 msec. may be selected.   
					Volume may also be adjusted.   
					Buzzer Before Transmission - The good read buzzer will be activated after decoding the bar code, but before transmission.   
					During transmission, the buzzer sequence will be completed.   
					Buzzer After Transmission - The good read buzzer will be activated after transmission.   
					Enable Startup Buzzer - When this option is selected, the reader will generate a single good read buzzer to indicate the reader is   
					ready after the reader is supplied with power.   
					Disable Startup Buzzer - When this option is selected, the reader will not sound the buzzer after the reader is supplied with   
					power.   
					Page 59   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					Good Read LED   
					Start/End   
					Program   
					Menu   
					ZZ   
					T4   
					T5   
					T6   
					T7   
					[[   
					U5   
					U6   
					U7   
					U8   
					Disable   
					indicator   
					Indicator   
					duration   
					0.2 sec.   
					% 
					Indicator   
					duration   
					0.4 sec.   
					Indicator   
					duration   
					0.8 sec.   
					Diagnostics   
					Start/End   
					Program   
					Menu   
					ZZ   
					Z1   
					[[   
					[2   
					[!   
					[B   
					ZW   
					UI   
					UJ   
					Transmit   
					software   
					version   
					Transmit   
					settings   
					Z3   
					Transmit   
					ASCII   
					printable   
					string   
					ZA   
					YV   
					TH   
					TI   
					Transmit   
					ASCII control   
					string   
					Error msg.   
					label   
					Error msg. no   
					decode   
					Page 60   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 
			 
		 
		
			
			
				
					Manual No. 25-ULGPMU01-01   
					Series LGP Handheld CCD Scanner   
					History of changes to Manual   
					Sept 2002   
					Corrected programming bar codes for Computer Type Selection (keyboard wedge).   
					Changed: “OPT” Series to “LGP” Series   
					November 2005   
					Added keyboard wedge and USB options programming commands   
					February 2006   
					Correct enable Code 39 Full ASCII   
					Page 61   