Introduction
Thank you for purchasing the OMRON Comp Air Elite.
This product was developed in conjunction with respiratory therapists for the
successful treatment of asthma, chronic bronchitis, allergies and other respiratory
disorders. The compressor forces air to the nebuliser. When the air enters the
nebuliser, it converts the prescribed medication into an aerosol of microscopic
droplets that can easily be inhaled.
The Comp Air Elite is a medical device. Operate this device only as instructed by
your doctor and/or respiratory therapist.
Intended use
Medical Purpose
Intended User
This product is intended to be used for inhaling medication
for respiratory disorders.
• Legally certified medical experts, such as doctor, nurse and
therapist, or healthcare personnel or patient under the
guidance of qualified medical experts.
• The user should also be capable of understanding general
machine operation and the content of instruction manual.
Intended Patients
Environment
This product should not be used by patients, who are
unconscious or are not breathing spontaneously.
This product is intended for use in a medical facility, such as
Hospital, clinic and doctor’s office, in a room of general
household, and in open-air environment with a roof.
Durable period
Durable periods are as follows, provided the product is used
to nebulise saline 3 times a day for 10 minutes each time at
room temperature (23°C).
Durable period may vary depending on usage environment.
EN
Main unit
5 years
Nebuliser Kit
(Cap, Inhalation Air Inlet, Baffle, Medication Cup) 1 year
Mouthpiece
Air Tube
Air Filter
1 year
1 year
60 days
1 year
Child Mask
Adapter for Child Mask 1 year
Precautions for use Warnings and cautions described in the instruction manual
should be observed.
Download from Www.Somanuals.com. All Manuals Search And Download.
3
Important safety instructions
Read all the information in the instruction manual and any other literature included
in the box before using the device.
When using an electrical product, especially when children are present, basic
safety precautions should always be followed including the following:
Warning:
Indicates a potentially hazardous situation which, if not avoided, could result in
serious injury.
(Usage)
• For type, dose, and regime of medication follow the instructions of your doctor or
respiratory therapist.
• Do not use only water in the nebuliser, for nebulising purposes.
• Clean and disinfect the nebuliser kit, mouthpiece and optional nosepiece or
masks before using them for the first time after purchase, if the device has not
been used for a long period of time, or if more than one person uses the same
device.
• Be sure to wash the parts after use, and ensure that they are thoroughly
disinfected and dried, and stored in a clean location.
• Keep the device out of the reach of unsupervised infants and children. The
device may contain small pieces that can be swallowed.
• Store the device and accessories in a clean location.
• Do not store the air tube while there is moisture or medication remaining inside it.
• Always rinse the nebulising parts with clean hot tap water after disinfecting them.
Never leave the cleaning solution in the medication tank or mouthpiece.
• Do not use or store the device where it may be exposed to noxious fumes or
volatile substances.
• Do not use the device where it may be exposed to flammable gas.
• Make sure that the nebuliser kit is clean before use.
• Always dispose of any remaining medication after use, and use fresh medication
each time.
• Do not use in anaesthetic or ventilator breathing circuits.
(Risk of electrical shock)
• When using the optional rechargeable battery, always charge the battery fully
using the battery charger specially designed for this device. If the battery is
frequently used without being fully charged, the capacity of the battery will be
reduced and the device may stop during use. In this case have an alternative
power source, such as the AC adapter ready.
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Important safety instructions
• Do not use the main unit, AC adapter, optional rechargeable battery, or optional
battery charger while they are wet, or connect them to a power outlet or other
devices with wet hands.
• The compressor, AC adapter, and optional rechargeable battery and charger are
not waterproof. Do not spill water, or other liquids, on these parts. If liquid does
spill on these parts, immediately unplug the power cord and wipe off the liquid
with gauze or other absorbent material.
• Do not immerse the main unit in water or other liquid.
• Do not use or store the device in humid locations, such as a bathroom.
• Do not short circuit the battery terminals on the rechargeable battery. Make sure
battery terminals do not come in contact with keys, coins or other metal objects.
• When using the carrying bag to carry the device and optional rechargeable
battery, do not place hair pins or other metal objects in the bag.
• Use only original OMRON AC adapter for AC power outlet. Use of unsupported
AC adapter may damage the device.
• Do not operate the unit with a damaged cord or plug.
• Keep the power cord away from heated surfaces.
Read and follow the “Important information regarding Electro Magnetic
Compatibility (EMC)” in the Technical Data Section.
Caution:
Indicates a potentially hazardous situation which if not avoided, may result in minor
or moderate injury, or physical damage.
(Usage)
• Provide close supervision when this device is used by, on, or near children or
invalids.
• Make sure that the parts are attached correctly.
• Make sure that the vaporiser head is correctly installed before use.
• Make sure that the air filter is correctly attached.
EN
• Make sure that the air filter is clean. If the air filter has changed colour, or has
been used on average for more than 60 days, replace it with a new one.
• Do not spill liquid or medication on the compressor.
• Do not tilt the nebuliser kit so that it is at an angle of greater than 45°, or shake it
while in use.
• Do not use or store the device while the air tube is creased.
• Use only original nebulising parts, air tube, air filter and filter cover.
• Do not add more than 7 ml of medication to the medication tank.
• Do not carry or leave the nebuliser kit while the medication tank contains
medication.
Download from Www.Somanuals.com. All Manuals Search And Download.
5
Important safety instructions
• Do not leave the unit unattended with infants or persons who cannot express
their consent.
• Do not subject the device or the parts to any strong shocks such as dropping the
device on the floor.
• Do not distort the vaporiser head, or jab the nozzle of the medication tank with a
pin etc.
• Do not cover the compressor, optional rechargeable battery and charger with a
blanket or towel etc., during use.
• Do not insert fingers or objects inside the compressor.
• Do not disassemble or attempt to repair the compressor, AC adapter, optional
rechargeable battery or charger.
• Do not leave the device or its parts where is will be exposed to extreme
temperatures or changes in humidity, such as in a vehicle during the summer, or
where it will be exposed to direct sunlight.
• Do not block the air filter cover.
• When sterilising parts by boiling, make sure that the container does not boil dry.
• Never place, or attempt to dry the compressor, AC adapter or nebulising parts in
a microwave oven.
• Do not use the device while sleeping or if drowsy.
• To avoid injury to the nose mucosa, do not squeeze the nosepiece into the back
of the nose.
• Do not block the slit between the cap and the inhalation air inlet.
• Do not use a microwave oven or hair dryer to dry the nebulising parts.
• Approved for human use only.
(Risk of electrical shock)
• Always unplug the AC adapter from the power outlet after use and before
cleaning.
• Plug the device into the appropriate voltage outlet. Do not overload power outlets
or use extension cords.
• Always read the instructions included with optional parts, such as the
rechargeable battery and charger, before using them.
• Always remove the optional battery and AC adapter from the device after use
and before cleaning.
• Do not misuse the cord of the AC adapter.
• Do not wind the cord of the AC adapter around the main unit or AC adapter.
• Changes or modifications not approved by OMRON Healthcare will void the user
warranty.
Download from Www.Somanuals.com. All Manuals Search And Download.
6
Important safety instructions
General Safety Precautions:
• Inspect the device and parts before using them each time, and check that there
are no problems. In particular, be sure to check the following:
- That the vaporiser head, nozzle or air tube are not damaged.
- That the nozzle is not blocked.
- That the compressor operates normally.
• When using this device, there will be some noise and vibration caused by the
pump in the compressor. There will also be some noise caused by the emission
of compressed air from the nebuliser kit. This is normal and does not indicate a
malfunction, or reduce the working life of the device.
• Limit use to 20 minutes at a time, and allow a 40 minute interval before using the
device again.
• Operate the device only as intended. Do not use the device for any other
purpose.
• Do not use the device at temperatures greater than +40°C.
• Do not spill liquid or medication on the battery connector, optional rechargeable
battery or charger connectors, or allow them to become dusty. Immediately wipe
off the liquid or dust with gauze or other absorbent material.
• Make sure that the air tube is securely attached to the compressor (main unit)
and nebuliser kit, and does not come loose. Twist the airtube plug slightly when
inserting it into the connectors to avoid the tube disconnecting during use.
• The AC adapter is provided so that the unit can be completely isolated from the
power source. To completely isolate the unit from the power source unplug the
AC adapter from the power source.
Read and follow the “Correct Disposal of This Product” in the Technical Data
Section when disposing of the device and any used accessories or optional parts.
Save these instructions for future reference.
EN
Download from Www.Somanuals.com. All Manuals Search And Download.
7
1. Know your unit
D
A
C
A1
A2
A3
D1
D2
D3
D4
5
3
E
A4
A5
A6
E1
B1
E2
E3
B2
B
E4
Rear View
Bottom View
E5
E7
E6
5
3
A7
A8
A. Compressor (Main Unit)
A1. Power Indicator
A2. Power Switch
D. Inhalation Attachments
D1. Mouthpiece
D2. Adult Mask (PVC)
D3. Child Mask (PVC)
D4. Nosepiece
A3. Charge Indicator
A4. Air Connector
A5. Filter Cover (* Air filter inside.)
A6. Nebuliser Kit Holder
A7. AC Adapter Jack
A8. Battery Connector
B. Air Tube (PVC, 207cm)
B1. Air Plug
E. Nebuliser Kit
E1. Cap
E2. Inhalation Air Inlet
E3. Inhalation Top
E4. Vaporiser Head
E5. Medication Tank
E6. Nozzle
B2. Air Plug
C. Nebulising Parts
E7. Air Tube Connector
Download from Www.Somanuals.com. All Manuals Search And Download.
8
1. Know your unit
Accessories
F
G2
H
G1
G
I
J
F. Spare Air Filters x 5
G. AC Adapter
I. Instruction Manual
J. Warranty Card
G1. Power Connector
G2. Power Cord
H. Carrying Bag
Material of attachment
Nebuliser Kit, Mouthpiece, Nosepiece, Adapter for
Child Mask (SEBS):
Polypropylene
Adult Mask (PVC), Child Mask (PVC):
Adult Mask (SEBS), Child Mask (SEBS):
Air Tube:
PVC
EN
SEBS
PVC and Polypropylene
Air Filter:
Polyester
ABS
Air Filter Cover:
• Also applicable Section 10. Optional parts and accessories.
Download from Www.Somanuals.com. All Manuals Search And Download.
9
2. Guide to using the Comp Air Elite
Preparing the Nebuliser for Use (Section 3)
Note: Clean and disinfect the nebuliser kit and applicable inhalation
attachments before using the device for the first time, or if it has not
been used for more than one week.
Taking Medication (Section 4)
Notes:
• Do not tilt the nebuliser kit so that it is at an
angle of greater than 45°.
5
• Do not crease or fold the air tube.
Cleaning Parts After Use (Section 5)
Note: Failure to clean the nebulising parts
after use may lead to infection.
How the nebuliser kit works
Baffle
The compressed air from the
Aerosol
Aerosol
compressor is forced through the
nozzle, as it does so, it is mixed with
the medication in the vaporiser head
and forced upwards. The medication
is then turned into a fine aerosol and
directed upwards by the baffle,
where it is broken down into many
smaller aerosol particles.
Vaporiser
Head
Nozzle
Medication
Medication
Compressed Air
Download from Www.Somanuals.com. All Manuals Search And Download.
10
Operating instructions
3. Preparing the nebuliser for use
Warning:
Clean and disinfect the nebuliser kit, mouthpiece and optional nosepiece or
masks before using them for the first time after purchase, if the device has
not been used for a long period of time, or if more than one person uses the
same device.
For directions on cleaning and disinfecting the parts of the device refer to Section 5
in this instruction manual.
Note: Make sure that the air filter is changed regularly. (See “7. Changing the air
filter”.)
3.1 Connecting the AC adapter
1. Insert the power connector of the AC adapter
into the AC adapter jack on the compressor.
Power Connector
AC Adapter Jack
2. Plug the AC adapter into a power outlet.
Power Outlet
EN
Note: When disconnecting the AC adapter, unplug the AC adapter from
the power outlet before removing the power connector on the
compressor.
Download from Www.Somanuals.com. All Manuals Search And Download.
11
3. Preparing the nebuliser for use
3.2 Adding medication and assembling the parts
1. Remove the mouthpiece and cap from the
nebuliser kit.
2. Remove the inhalation top from the medication
2
tank.
1) Rotate the inhalation top anti-clockwise.
1
2) Lift the inhalation top out of the medication
tank.
5
3
3. Remove the vaporiser head from the medication
tank.
4. Add the correct amount of prescribed
medication to the medication tank.
Caution: The capacity of the medication
tank is 2 to 7 ml.
max
5
3
Note: Scales on the nebuliser kit are for
reference only. The scale on the outside
of the tank is with vaporiser head in place.
The scale on the inside is with no vaporiser head. Please use the
scale on your syringe or vial for accurate measurement of
medication.
Download from Www.Somanuals.com. All Manuals Search And Download.
12
3. Preparing the nebuliser for use
5. Reattach the vaporiser head to the medication
tank.
6. Put the inhalation top back inside the
medication tank.
1
1) Align the protrusion on the inhalation top
with the indent on the medication tank, as
shown.
max
5
3
2) Rotate the inhalation top clockwise and align
with the medication tank until they click in
place.
2
7. Attach the desired inhalation attachment, as described below.
Attaching the mouthpiece
2
Make sure you also attach the cap, when using
the mouthpiece.
1
1) Attach the cap to the inhalation air inlet.
2) Attach the mouthpiece to the inhalation top.
EN
Attaching the adult mask (PVC)
Attach the mask to the inhalation top.
Note: If the amount of aerosol is too great,
attach the cap.
Download from Www.Somanuals.com. All Manuals Search And Download.
13
3. Preparing the nebuliser for use
Attaching the child mask (PVC)
Attach the mask to the inhalation top.
1) Attach the cap to the inhalation air inlet.
2) Attach the child mask to the inhalation top.
2
1
Attaching the nosepiece
Attach the cap when using the nosepiece.
1) Attach the cap to the inhalation air inlet.
2) Attach the nosepiece to the inhalation top.
2
1
Download from Www.Somanuals.com. All Manuals Search And Download.
14
3. Preparing the nebuliser for use
8. Attach the air tube.
1) Attach the air tube to the air connector on the compressor.
2) Attach the other end of the air tube to the air tube connector on the
medication tank.
2
1
Notes:
• Make sure that the air tube is securely attached to the compressor (main
unit) and nebuliser kit, and does not come loose. Twist the airtube plug
slightly when inserting it into the connectors to avoid the tube
disconnecting during use.
• Take care not to spill the medication when attaching the air tube. Keep
the nebuliser kit upright.
• Use the nebuliser kit holder as a temporary
holder for the nebuliser kit.
EN
Download from Www.Somanuals.com. All Manuals Search And Download.
15
4. Taking medication
1. Hold the nebuliser kit as indicated on the right.
Caution:
Do not tilt the nebuliser kit so that
it is at an angle of greater than
45°. Medication may flow into the
mouth.
45°
2. Press the power switch.
The compressor starts and nebulisation
starts.
Notes:
• The green light shows that the power is
on.
• Observe whether aerosol is generated.
To stop nebulisation
Press the power switch again. The light goes out.
Caution:
Do not block the air filter cover.
Notes:
• Do not leave the compressor on for a long period of time. This could
result in the compressor overheating or malfunctioning.
• Limit use to 20 minutes at a time, and allow a 40 minute interval (cool off
period) before using the device again.
Download from Www.Somanuals.com. All Manuals Search And Download.
16
4. Taking medication
3. Inhale medication according to your doctor’s and/or health care adviser’s
instructions.
Using the mouthpiece
Prepare your mouthpiece according to
Section 3.2.7.
Insert the mouthpiece into your mouth and
inhale the medication breathing normally.
Exhale as normal through the mouthpiece.
Using the nosepiece
Prepare your nosepiece according to
Section 3.2.7.
Inhale the medication through the nosepiece, as
shown and exhale through the mouth.
Using the adult mask (PVC)
Attach the mask so that it covers your nose and
mouth and inhale the medication.
Exhale through the mask.
Note: If the amount of aerosol is too great,
attach the cap.
Using the child mask (PVC)
EN
Prepare your child mask according to
Section 3.2.7.
Attach the mask so that it covers your nose and
mouth and inhale the medication.
Exhale through the mask.
Download from Www.Somanuals.com. All Manuals Search And Download.
17
4. Taking medication
4. When treatment is complete, turn the power off. Check that there is no
condensation or moisture in the air tube and unplug the device from the
power outlet.
Power Outlet
Warning:
Condensation may occur in the air tube. Do not store the air tube
while it contains condensation or moisture. This could result in
infection via bacteria.
If there is moisture or liquid remaining in the air tube, be sure to follow the
procedure below to remove any moisture from within the air tube.
1)Make sure that the air tube is still connected to the air connector on the
compressor.
2)Unplug the air tube from the nebuliser kit.
3)Turn on the compressor and pump air through the air tube to expel the
moisture.
Download from Www.Somanuals.com. All Manuals Search And Download.
18
Care and maintenance
5. Cleaning and daily disinfecting
5.1 Cleaning
Following the cleaning instructions after each use will prevent any remaining
medication in the tank from drying, resulting in the device not nebulising effectively
and also for preventing infections.
Warning:
Thoroughly rinse the nebuliser and the mask, nosepiece or mouthpiece with
clean hot tap water after each use, and disinfect the parts of the nebuliser kit
and applicable inhalation attachments after the last treatment of the day.
Note: Do not start operation before the cleaned parts are completely dried.
1. Make sure that the power indicator is out.
Power Indicator
2. Disconnect the AC adapter from the wall outlet
and the compressor.
3. Remove the nebuliser kit from the air tube and disassemble the nebuliser
kit. (see Section 3)
4. Discard any remaining medication in the
medication tank.
EN
5. Wash all the nebulising parts in warm water and mild detergent and rinse in
clean hot tap water, or wash in a dishwasher.
For instructions on how to disinfect the parts, see the following section.
Download from Www.Somanuals.com. All Manuals Search And Download.
19
5. Cleaning and daily disinfecting
6. After cleaning and disinfecting the parts, rinse them thoroughly with clean
water and allow the parts to air dry in a clean environment.
5
3
7. If the compressor is dirty, wipe it clean with a soft
cloth moistened with water or mild detergent.
Caution: The compressor is not
waterproof.
8. If the outside of the air tube is dirty, wipe it clean
with a soft cloth moistened with water or mild detergent.
9. Reassemble the nebuliser kit. Put the parts in a dry, sealed bag and place
in the storage pocket of the carrying bag.
Note: Nebuliser kit should be replaced after using for 6 months.
5.2 Disinfecting the nebulising parts
Always clean before disinfection. (See Section 5.1)
Always disinfect the medication tank, mouthpiece and other nebulising parts after
the last treatment of the day. To disinfect the parts, use one of the methods
described below:
A.Use a commercially available disinfectant. Follow the instructions provided by
the disinfectant manufacturer.
1. Submerge the parts in the cleansing solution for the specified period.
2. Remove the parts and discard the solution.
3. Rinse the parts with clean hot tap water, shake off excess water and allow
to air dry in a clean environment.
B.Parts may be boiled between 15 to 20 minutes (except for PVC mask).
After boiling, carefully remove the parts, shake off excess water and allow to air dry
in a clean environment.
Download from Www.Somanuals.com. All Manuals Search And Download.
20
5. Cleaning and daily disinfecting
Handling the Vaporiser Head
The vaporiser head is an important part that is used to vaporise medication.
Be sure to observe the following precautions when handling it.
Caution:
• Always wash the vaporiser head after each
use. Failure to do so could cause blockages
and a deterioration in your condition due to a
failure to vaporise medication effectively.
Baffle
• Do not use a brush or pin etc., to clean the
parts. This could damage the baffle and cause
a deterioration in your condition due to a fail-
ure to vaporise medication effectively.
• When disinfecting the parts by boiling, be
sure to boil them in plenty of water. If there is
insufficient water, the parts could become dis-
torted due to the high temperature near the
bottom of the pan. Distorted parts could
Vaporiser head
cause a deterioration in your condition due to a failure to vaporise medi-
cation effectively.
• Do not boil vaporiser head together with other objects, other than appli-
cable nebuliser accessories. This could damage the baffle and cause a
deterioration in your condition due to a failure to vaporise medication
effectively.
• Do not use a microwave oven, dish dryer or hair dryer to dry parts. The
parts could become distorted due to the high temperature and cause a
deterioration in your condition due to a failure to vaporise medication
effectively.
EN
Download from Www.Somanuals.com. All Manuals Search And Download.
21
6. Maintenance and storage
To keep your device in the best condition and protect the device from damage
follow these directions:
Caution:
• Do not leave the unit unattended with infants or persons who cannot
express their consent.
• Do not subject the device or the parts to any strong shocks such as
dropping the device on the floor.
Notes:
• Do not store the device in extreme hot or cold temperatures, high humidity or
under direct sunlight.
• Do not crease or fold the air tube.
• Dispose of the device and any used accessories or optional parts according to
applicable local regulations.
• Never clean with benzene, thinner or a flammable chemical.
Always transport the device in its carrying bag, and store the
device in the bag if it will not be used for a long period.
Caution:
Do not carry or leave the nebuliser while the medication tank contains
medication.
Download from Www.Somanuals.com. All Manuals Search And Download.
22
7. Changing the air filter
On average, the air filter should be changed every 60 days or so, or when the filter
has changed colour from white.
1. Pull the air filter cover off the compressor.
2. Change the air filter.
Remove the old air filter with a sharp object,
such as a toothpick, and insert the new air
filter.
3. Put the air filter cover back in place.
Notes:
• Use only OMRON air filters designed for this
unit. Do not operate without a filter.
• There is no front or back orientation for the
air filters.
• Check that air filters are clean and free of dust before inserting them.
• Do not attempt to wash or clean the filter. If the air filter becomes wet,
replace it. Damp air filters can cause blockages.
• To prevent the air filter cover from becoming blocked, wash the cover
regularly. Do not boil the air filter cover.
EN
Remove the air filter cover, wash it, and make sure it is dry and
reattached correctly.
• Please contact your OMRON dealer for additional air filters, or if the parts
supplied with the device are damaged or missing.
Download from Www.Somanuals.com. All Manuals Search And Download.
23
8. Troubleshooting
Check the following if your unit should fail during operation. You can also refer to
the pages of this manual for complete instructions.
Symptom
Cause
Remedy
Check that the plug is
inserted in an electrical
outlet. Unplug then reinsert
the plug if necessary.
Is the AC adapter connected
correctly to the an electrical
outlet and the compressor?
Nothing happens when the
power switch is pressed.
(The power indicator does
not light.)
Is the optional rechargeable Make sure that the battery is
battery connected correctly? correctly attached.
Is the optional rechargeable
Charge the battery.
battery charged sufficiently?
Is the optional DC auto
Make sure that the adapter
adapter connected
is correctly attached.
correctly?
Is there medication in the
Fill the medication tank.
medication tank?
Is there too much/little
Add the correct amount of
medication in the medication medication to the medication
tank?
tank.
Is the vaporiser head
missing and not assembled
correctly?
Attach the vaporiser head
correctly.
Is the nebuliser kit
assembled correctly?
Assemble the nebuliser kit
correctly.
Make sure that the nozzle is
free of blockages.
No nebulisation or low
nebulisation rate, when the
power is on. (The green
power indicator is lit.)
Is the nozzle blocked?
Make sure that the nebuliser
kit is not tilted at an angle of
more than 45 degrees.
Is the nebuliser kit tilted at a
sharp angle?
Make sure that the air tube is
correctly connected to the
compressor and nebuliser.
Is the air tube connected
correctly?
Is the air tube folded or
damaged?
Make sure that the air tube
does not contain kinks.
Make sure that the air tube is
free of blockages.
Is the air tube blocked?
Is the air filter dirty?
Replace the air filter with a
new one.
The device is abnormally
loud.
Is the air filter cover attached Attach the air filter cover
correctly? correctly.
Download from Www.Somanuals.com. All Manuals Search And Download.
24
8. Troubleshooting
Symptom
Cause
Remedy
The compressor is covered
by a cloth.
The device is very hot.
Remove the cloth.
Is the optional rechargeable
battery charged sufficiently?
Charge the battery.
The battery has expired and
cannot be recharged
enough.
Replace with a new battery.
Charge the battery.
The device stops soon when
using the optional
rechargeable battery, or
operation time is short.
Has the battery been left
unused for a long time?
Rundown, then recharge the
battery two or three times.
(See Section 11)
Is the battery allowed to fully
rundown before it is
recharged?
Notes:
• If the suggested remedy does not solve the problem, do not try to repair the
device - no parts of the unit are user serviceable.
Return the unit to an authorized OMRON retail outlet or distributor.
• The device should be serviced once a year by an approved OMRON service
centre.
EN
Download from Www.Somanuals.com. All Manuals Search And Download.
25
9. Technical data
Name:
Comp Air Elite
Model:
OMRON NE-C30-E
Type:
Power Supply:
Non-heating compressor nebuliser
12VDC 1A (Compressor)
100 - 240VAC, 50/60Hz (AC adapter)
12 watts
Power Consumption:
Operating Temperature/
Humidity:
+10°C to +40°C 30% to 85% RH
Storage Temperature/
Humidity/Air Pressure:
-20°C to +60°C 10% to 95% RH 700 - 1060 hPa
Weight:
440 g (compressor only)
Dimensions:
Contents:
Approx. 124 (W) × 52 (H) × 103 (D) mm (compressor only)
Compressor, Nebuliser Kit, Air Tube (PVC, 207cm),
5 pcs Replacement Filters, Mouthpiece, Adult Mask (PVC),
Child Mask (PVC), Nosepiece, AC Adapter, Carrying Bag,
Instruction Manual, Warranty Card.
Notes:
• Subject to technical modification without prior notice.
• This OMRON product is produced under the strict quality system of OMRON Healthcare Co. Ltd.,
Japan.
• The device may not work if the temperature and voltage conditions are different to those defined in
the specifications.
Download from Www.Somanuals.com. All Manuals Search And Download.
26
9. Technical data
Technical data for the OMRON Comp Air compressor with the OMRON V.V.T.
(Virtual Valve Technology) Nebuliser kit:
Particle Size:
Medication Tank
Capacity:
*MMAD **approximately 3µm
7 ml maximum
Appropriate Medication
Quantities:
2 ml minimum - 7 ml maximum
Sound:
Noise level (at 1 m distance) 53 db
0.35 ml/min (by weight loss)
**0.3 ml (2ml, 1%NaF)
Nebulisation Rate:
Aerosol Output:
Aerosol Output Rate:
**0.05 ml/min (2ml, 1%NaF)
Notes:
• Performance may vary with drugs such as suspensions or high viscosity. See
drug supplier’s data sheet for further details.
• The data above is referenced by Omron Healthcare.
• See web site of Omron Healthcare Europe to update technical information.
Result of cascade impactor** measurements for particle size with OMRON
NE-C30-E and OMRON V.V.T. Nebuliser kit
Cumulative % particle mass of sodium fluoride under size
100
90
80
70
60
50
40
30
Individual tests
20
10
0
Mean
MMAD: 3µm
EN
0.1
1
10
100
Particle Size Dp (µm)
*MMAD = Mass Median Aerodynamic Diameter
**Independently measured at SolAero Ltd., Canada, Dr. John Dennis, according to
EN 13544-1
Download from Www.Somanuals.com. All Manuals Search And Download.
27
9. Technical data
Notes:
= Type B
= Type B
• Do not use the device where it may be exposed to flammable gas.
• This device fulfils the provisions of the EC directive 93/42/EEC (Medical Device
Directive) and the European Standard EN13544-1:2007, Respiratory therapy
equipment - Part1: Nebulizing systems and their components.
= Class ll
= Read the instruction manual carefully
Important information regarding Electro Magnetic Compatibility (EMC)
With the increased number of electronic devices such as PC’s and mobile
(cellular) telephones, medical devices in use may be susceptible to
electromagnetic interference from other devices. Electromagnetic interference
may result in incorrect operation of the medical device and create a potentially
unsafe situation.
Medical devices should also not interfere with other devices.
In order to regulate the requirements for EMC (Electro Magnetic Compatibility)
with the aim to prevent unsafe product situations, the EN60601-1-2 standard
has been implemented. This standard defines the levels of immunity to
electromagnetic interferences as well as maximum levels of electromagnetic
emissions for medical devices.
This medical device manufactured by OMRON Healthcare conforms to this
EN60601-1-2:2007 standard for both immunity and emissions.
Nevertheless, special precautions need to be observed:
• Do not use mobile (cellular) telephones and other devices, which generate
strong electrical or electromagnetic fields, near the medical device. This may
result in incorrect operation of the unit and create a potentially unsafe
situation. Recommendation is to keep a minimum distance of 7 m. Verify
correct operation of the device in case the distance is shorter.
Further documentation in accordance with EN60601-1-2:2007 is available at
OMRON Healthcare Europe at the address mentioned in this instruction
manual.
Download from Www.Somanuals.com. All Manuals Search And Download.
28
9. Technical data
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
This marking shown on the product or its literature, indicates that it should not
be disposed of, with other household wastes at the end of its working life. To
prevent possible harm to the environment or human health from uncontrolled
waste disposal, please separate this from other types of wastes and recycle it
responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this
product, or their local government office, for details of where and how they can
take this item for environmentally safe recycling.
Business users should contact their supplier and check the terms and
conditions of the purchase contract. This product should not be mixed with
other commercial wastes for disposal.
This product does not contain any hazardous substances.
EN
Download from Www.Somanuals.com. All Manuals Search And Download.
29
10.Optional parts and accessories
OMRON V.V.T. Nebuliser
Kit Set
Air Tube (PVC, 207cm)
Order No. 9956270-0
Mouthpiece
Order No. 9956273-5
Order No. 9956268-9
Nebuliser Kit
Air Tube (Silicon, 100cm)
Order No. 9956269-7
Nosepiece
Order No. 9956274-3
Mouthpiece
Child Mask (SEBS) Set
Adult Mask (SEBS)
Adult Mask (PVC)
Order No. 9956281-6
Order No. 9956312-0
Order No. 9956275-1
Child Mask (SEBS)
Child Mask (PVC)
Order No. 9956276-0
Air Filters (x 5)
Order No. 9956636-6
Adapter for
Child Mask (SEBS)
Download from Www.Somanuals.com. All Manuals Search And Download.
30
10. Optional parts and accessories
Filter Cover
Order No.9956638-2
Instruction Manual
Order No.9956633-1
Carrying Bag
Order No.9956631-5
Battery Set
Includes the rechargeable battery,
battery charger.
Rechargeable Battery
Order No.9986457-0
Battery Charger
Order No.9986461-8
Order No.9986453-7
AC Adapter
Order No.9956628-5
EN
Download from Www.Somanuals.com. All Manuals Search And Download.
31
11.Using optional accessories
11.1 Using the optional rechargeable battery
Use the rechargeable battery as shown in the chart below. For details, refer to the
following pages.
When the battery has
Using the battery for
not been used for a
the first time.
while.
Fully charge the battery.
Attach the battery to the
Attach the battery to the
main unit and use the
main unit.
device.
Notes:
• Limit use to 20 minutes at a time.
• If the battery is frequently used
without being fully charged, have
an alternative power source ready.
Charge indicator lights?
No
Yes
Operate the device until the
charge indicator lights.
Charge the battery before
using it next time.
Download from Www.Somanuals.com. All Manuals Search And Download.
32
11. Using optional accessories
Important notes on using the optional rechargeable battery
• Charge the battery before using it for the first time. The battery is not charged
at the time of shipment.
• Use the optional charger to charge the battery. The battery takes about 3 hours
to charge fully.
• A fully charged battery can be used to operate the device for approximately 35
minutes, when used within the normal operating temperature range.
Note: Limit use to 20 minutes at a time, and allow a 40 minute interval before
using the device again.
• Use the battery until the charge indicator on the main unit lights.
• The battery can be charged approximately 300 times. After 300 charges the
operating capacity of the battery will be reduced to about half its normal
capacity. We therefore recommend that you replace the rechargeable battery
with a new one after 300 charges. (If the battery is charged once each day and
is used for three sessions each day, the battery should last for approximately
one year.)
• Always recharge the battery before using it again. Even if the battery has been
fully charged after the previous use, its operating time can be reduced due to
self-discharge.
1. Charge the battery.
1) Insert the power connector of the AC adapter into the AC adapter jack
on the charger.
2) Plug the AC adapter into a power outlet.
2
EN
1
Download from Www.Somanuals.com. All Manuals Search And Download.
33
11. Using optional accessories
3) Attach the optional battery to the
Charging Indicator blinks
charger.
Align the connectors on the battery and
charger, and press the battery until it
clicks into place. Charging starts and the
green charging indicator blinks.
3
2. After the battery is fully charged, remove the battery from the charger.
The green charging indicator changes from blinking to remaining
continuously lit when the battery is fully charged.
1) Unplug the AC adapter from the
ChargingIndicator
remains lit
power outlet, then disconnect the
charger.
2) While pressing the button on the side
of the battery, lift the battery off the
charger.
Push Button
3. Mount the compressor on the battery.
Align the connector on the bottom of the compressor with that on the
battery and mount the compressor on the battery. Push the compressor
down until it clicks into place.
Note: To separate the compressor and battery,
press the push button on the side of the
battery and lift the compressor off the battery.
Push Button
Download from Www.Somanuals.com. All Manuals Search And Download.
34
11. Using optional accessories
When battery power is low
The charge indicator on the main unit will light
when battery power is low. Please note the
following points about using the device after the
charge indicator lights:
• Stop using the device when the charge indicator
comes on.
• Battery power is low and the device will cease to
operate shortly after the charge indicator comes
on.
Charge Indicator
• To continue using the device after the charge indicator comes on, use the AC
adapter or an alternative power source to power the device.
• Always fully charge the battery before using it again after the charge indicator
lights.
• If the operating time for each charge when using the battery become noticeably
shorter than usual, refer to “About the Memory Effect” below.
If the battery will not be used for a long time
• If the battery is not used for approximately 10 days after being charged, the
battery capacity will be reduced to about half that of normal due to self-discharge
of the battery power. If the battery will not be used for a long time, use the battery
until the charge indicator on the main unit lights (to fully discharge the battery)
before charging it.
About the Memory Effect
• If the battery is repeatedly charged before it has fully discharged, the operating
time possible for each charge will gradually be reduced. This is known as the
“memory effect” and is normal for nickel metal hydride (NiMH) batteries. It does
not indicate a battery error or malfunction.
EN
• If the operating time for each charge become reduced, fully charge the battery
and operate the device until the unit stops operating (rather then when the charge
indicator lights) two or three times in a row. This should restore the battery
capacity to normal. If the battery capacity does still not return to normal, replace
the battery with a new one.
Download from Www.Somanuals.com. All Manuals Search And Download.
35
Manufacturer
OMRON HEALTHCARE Co., Ltd.
53, Kunotsubo, Terado-cho, Muko, Kyoto,
617-0002 JAPAN
EU-representative
OMRON HEALTHCARE EUROPE B.V.
Scorpius 33, 2132 LR Hoofddorp
THE NETHERLANDS
OMRON (DALIAN) CO., LTD.
Production facility
Subsidiary
Dalian, CHINA
OMRON HEALTHCARE UK LTD.
Opal Drive
Fox Milne, Milton Keynes, MK15 0DG, U.K.
OMRON MEDIZINTECHNIK HANDELSGESELLSCHAFT mbH
John-Deere-Str. 81a, 68163 Mannheim, GERMANY
OMRON SANTÉ FRANCE SAS
14, rue de Lisbonne, 93561 Rosny-sous-Bois Cedex, FRANCE
Made in China
Download from Www.Somanuals.com. All Manuals Search And Download.
36
|