HH147  
Handheld Thermometer  
K/J/T/E/R/S/N Types  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction .................................................. 1  
Features ........................................................ 2  
General Specifications ................................ 3  
Electrical Specifications ............................. 4  
Names of Parts ............................................ 5  
Operation ...................................................... 6  
RS-232 Operation ...................................... 16  
RS-232 Installation Proceedure ................ 24  
RS-232 Operation of Software .................. 26  
Battery Replacement ................................. 34  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction  
Thank you for purchasing model HH147,  
RS232 Data Logger Thermometer. Please take  
a few minutes to browse through this user  
manual before you begin to operate the unit to  
ensure that you are fully familiarized on how  
to best operate the meter.  
The model HH147 features a microprocessor-  
rated digital temperature gauge.  
HH147  
Four Channel  
K/J/T/E/R/S/N Types  
RS232 + Data Logger (with Back Light)  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Features  
1. Displays maximum value for four temperatures.  
2. Resolution: 0.1°C/0.1°F, 1°C/1°F.  
3. Swift response.  
4. Alert temperature range, setting.  
5. Auto power off function.  
6. Low batttery indicator function.  
7. Perpetual calendar function.  
8. “Count” function.  
9. T1-T4 exchange to main display function.  
10. T1-T2, T3-T4 function.  
11. Additional features: HOLD, °C/°F, REL, CHAN,  
MAX/MIN/AVG, 1°, TYPE, TIME (CLOCK  
setting), LIMIT (HiLo setting).  
12. CE certified, according to ITS-90.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
General Specifications  
1. Display Mode: Four-digit liquid crystal display.  
2. Polarity indicator: No indicator is shown when  
readouts are in the positive value while the  
symbol “-” is prompted when readouts fall into  
the negative value.  
3. Overload indicator: “OL” or “-OL” is displayed.  
B
4. Low battery indicator: The symbol “ ” is  
prompted on the LCD when the battery runs  
low.  
5. Power source: Four AAA batteries.  
6. Auto power off: The unit powers down after  
20 minutes of operation. Press the “Shift”  
key for 3 seconds, the auto power off will be  
disabled.  
7. Sample rate: 1 time/sec.  
8. Battery life: Approx. 550 hours.  
9. Operating Temperature and Humidity:  
0°~50°C (32°~122°F), 0~80%RH  
10. Storage Temperature and Humidity:  
-20°~60°C (-4~140°F), 0~80%RH.  
11. Dimension: 164x76x32mm (LxWxH).  
12. Weight: approx. 415g (includes batteries).  
13. Accessories:  
(A) AAA Battery (4pcs).  
(B) Housing (1pc).  
(C) K-type thermocouple wire (4pcs).  
(D) Users manual (1pc).  
(E) RS-232 cable (1pc).  
(F) RS-232 software CD (1pc).  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical Specifications  
1. Temp. unit: Celsius temp. (°C). Fahrenheit temp.  
(°F), Absolute temp. (K).  
2. Measurement Range: (At 23 5°C,<80%RH)  
K-type: -100~1300°C (-148~2372°F)  
J-type: -100~1000°C (-148~1832°F)  
T-type: -100~400°C (-148~752°F)  
E-type: -50~800°C (-58~1472°F)  
R&S-type: -0~1700°C (32~3092°F)  
NK-type: -100~1300°C (-149~2372°F)  
3. Accuracy: The basic accuracy does not include  
the error of the thermocouple.  
K/J/T/E/-type:  
(0.1% reading +0.7°C) -100°~-1300°C  
(0.1% reading +1.4°F) -148°~2372°F  
R/S-type:  
(0.1% reading +2°C) 0°~1700°C  
(0.1% reading +4°F) 32°~3092°F  
N-type:  
(0.1% reading +1.5°C) 100°~1300°C  
(0.1% reading +3°F) 148°~2372°F  
4. Resolution:  
1°C  
0.1°C  
-100°~1300°C  
-100°~1000°C  
-100°~400°C  
-50°~800°C  
0°~1700°C  
-100°~200°C  
-100°~150°C  
-100°~150°C  
-50°~100°C  
K
J
T
E
R
S
N
0°~1700°C  
-100°~1300°C  
-100°~150°C  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
1.  
: Power ON/OFF Key.  
Press the power button to turn the power  
ON or OFF.  
2. °C/°F/K: The Temp. Unit Selection Key.  
Press the key to sequentially alternate  
the three temp. units of °C, °F, and K.  
3. HOLD: The Readout Hold Function Key.  
Press the “HOLD” key, a “HOLD” icon  
will display on the LCD and the readout  
will be held in; press the “HOLD” key  
once more to cancel the “HOLD”  
function.  
4. MAX/MIN/Avg: The Maximum/Minimum/  
Average Readout Function Key  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
5. REL: The Minus Relative Readout Function Key.  
Press the “REL” key, a “REL” icon will  
display on the LCD and the original temp.  
will go to 0 and save the original temp.  
to make a standard value.  
Whenever the input temp. shifts, the LCD  
will show the minus value of the original  
temp. value and input temp. value.  
6.1°: 1° or 0.1° Unit Selection Function Key  
Press the “1” key, the whole resolution will  
become 1°C.1°F, and eliminate the dot. Press  
the key again and the display will be restored  
to the common state (the resolution will  
become 0.1°C/0.1°F).  
Note: The resolution of the thermocouple types  
is shown on page 4.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
8. TYPE: Select a thermocouple type function key.  
HH147 includes seven diffferent  
thermocouple types. The method of  
operation:  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
8. COUNT: The Count Time Setting Function Key.  
The max count time is 99 hours and  
59 minutes.  
10. TIME: To set the present time function key.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
13. LIMIT: To Enforce Alarm Function Key  
NOTE 1: The alarm will continue to be activated  
when the main display temp. value is  
higher than the alarm setting Hi temp.  
value or lower than the alarm Lo  
setting value.  
The Hi/Lo setting temp. values of the  
thermocouple types vary.  
2:  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
15. CLOCK: To Enforce Date Setting Function Key.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
16. Perpetual Calendar:  
Backlight:  
A. Press the backlight button to turn the  
backlight ON or OFF.  
B. If you do not disable the backlight  
feature, the backlight will stay on for  
1 minute.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
1. RS-232: When you turn on the “RS-232”  
function the auto power off and the  
power off will be cancelled.  
2. REC: When you turn on the “REC” function the  
reading value of the meter will transmit  
the settlement of interval in time, and will  
write down in the memory in real time.  
The maximum number of records is  
10000 records at most. When turning on  
“REC” function, the auto power off and  
the power off will be cancelled. When the  
memory is filled, the display will show “ou”.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
3. CALL: The HH147 can display the data of  
every channel, and can also inquire  
about the surplus space of the memory.  
When the “CALL” function is on, the  
auto power off will be cancelled.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
: When the RS-232 function is  
on the biggest settlement time  
is 59 minutes and 59 seconds.  
Minimum set time is one  
second.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
: When the record interval  
function is on, the biggest  
settlement time is 59 minutes  
59 seconds. Minimum set time  
is 1 second.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 Data Form  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 Data Form  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 Data Form  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 Software Installation Procedure  
1. Place CD-R into the CD-ROM driver.  
2. Installation may be automatic or manual in accordance  
with your personal software. The manual installation  
is: A. Pushing my computer, the mouse clicked two  
times. B. Pushing the CD-ROM driver, the mouse  
clicked two times. C. Pushing the “setup” file, the  
mouse clicked two times. Begin to enter installation  
procedure.  
3. Begin to install picture:  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 Software Installation Procedure  
25
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 Operation of Software  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 Operation of Software  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 Operation of Software  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 Operation of Software  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 Operation of Software  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 Operation of Software  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 Operation of Software  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 Operation of Software  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Battery Replacement  
B
1. The symbol “ ” that appears in the upper  
left of the LCD display indicates that the  
battery is running low. Please replace the AAA  
battery at once to ensure the test accuracy.  
2. Remove the battery cover with a screwdriver.  
3. Replace the old batteries with four new AAA  
batteries and lock the battery cover.  
4. Prior to replacing the battery, please make  
certain to remove the thermocouple from the  
temperature gauge as a safety precaution.  
5. When in extended idle, please remove the  
AAA battery from the temperature gauge and  
store the temperature gauge in a cool and  
low-humidity setting.  
6. To avoid combustion, DO NOT dispose of  
batteries into an open flame.  
7. Please note the position of the positive and  
negative polarity when loading battery.  
8. Please abide by pertinent laws and  
regulations when disposing of used batteries.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Caution  
1. Input protection: The temperature jack carry’s  
a maximum voltage of 34 volts DC or AC.  
2. Temperature jacks: Designed for insertion of  
a standard small thermocouple jack which  
have a center spacing of 7.9 mm between the  
two prongs.  
3. Please DO NOT place the HH147 inside a  
microwave for temperature testing.  
4. A correct thermocouple slot should be chosen  
when operating the temperature gauge.  
5. Please DO NOT attempt to use a temperature  
gauge that is not working properly. Consult  
Omega Customer Service for repair service  
at once.  
6. Please DO NOT attempt to operate the  
temperature gauge around sites where  
explosive gases, vapor, or dust particles are  
present.  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY/DISCLAIMER  
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and  
workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an  
additional one (1) month grace period to the normal one (1) year product warranty to cover  
handling and shipping time. This ensures that OMEGA’s customers receive maximum  
coverage on each product.  
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer  
Service Department will issue an Authorized Return (AR) number immediately upon phone or  
written request. Upon examination by OMEGA, if the unit is found to be defective, it will be  
repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting  
from any action of the purchaser, including but not limited to mishandling, improper interfacing,  
operation outside of design limits, improper repair, or unauthorized modification. This  
WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence  
of having been damaged as a result of excessive corrosion; or current, heat, moisture or  
vibration; improper specification; misapplication; misuse or other operating conditions outside of  
OMEGA’s control. Components in which wear is not warranted, include but are not limited to  
contact points, fuses, and triacs.  
OMEGA is pleased to offer suggestions on the use of its various products. However,  
OMEGA neither assumes responsibility for any omissions or errors nor assumes liability  
for any damages that result from the use of its products in accordance with information  
provided by OMEGA, either verbal or written. OMEGA warrants only that the parts  
manufactured by the company will be as specified and free of defects. OMEGA MAKES  
NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER,  
EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES  
INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR  
PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of pur-  
chaser set forth herein are exclusive, and the total liability of OMEGA with respect to this  
order, whether based on contract, warranty, negligence, indemnification, strict liability or  
otherwise, shall not exceed the purchase price of the component upon which liability is  
based. In no event shall OMEGA be liable for consequential, incidental or special damages.  
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as  
a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity;  
or (2) in medical applications or used on humans. Should any Product(s) be used in or with any  
nuclear installation or activity, medical application, used on humans, or misused in any way,  
OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language,  
and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability  
or damage whatsoever arising out of the use of the Product(s) in such a manner.  
RETURN REQUESTS/INQUIRIES  
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department.  
BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN  
AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT  
(IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be  
marked on the outside of the return package and on any correspondence.  
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to  
prevent breakage in transit.  
FOR WARRANTY RETURNS, please have  
the following information available BEFORE  
contacting OMEGA:  
1. Purchase Order number under which  
the product was PURCHASED,  
2. Model and serial number of the product  
under warranty, and  
3. Repair instructions and/or specific  
problems relative to the product.  
FOR NON-WARRANTY REPAIRS, consult  
OMEGA for current repair charges. Have the  
following information available BEFORE  
contacting OMEGA:  
1. Purchase Order number to cover the  
COST of the repair,  
2. Model and serial number of the  
product, and  
3. Repair instructions and/or specific problems  
relative to the product.  
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is  
possible. This affords our customers the latest in technology and engineering.  
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.  
© Copyright 2009 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied,  
photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in  
whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Where Do I Find Everything I Need for  
Process Measurement and Control?  
OMEGA…Of Course!  
Shop online at omega.comSM  
TEMPERATURE  
ߜ
 
ߜ
 
ߜ
 
ߜ
 
ߜ
 
Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies  
Wire: Thermocouple, RTD & Thermistor  
Calibrators & Ice Point References  
Recorders, Controllers & Process Monitors  
Infrared Pyrometers  
PRESSURE, STRAIN AND FORCE  
ߜ
 
ߜ
 
ߜ
 
ߜ
 
Transducers & Strain Gages  
Load Cells & Pressure Gages  
Displacement Transducers  
Instrumentation & Accessories  
FLOW/LEVEL  
ߜ
 
ߜ
 
ߜ
 
ߜ
 
Rotameters, Gas Mass Flowmeters & Flow Computers  
Air Velocity Indicators  
Turbine/Paddlewheel Systems  
Totalizers & Batch Controllers  
pH/CONDUCTIVITY  
ߜ
 
ߜ
 
ߜ
 
ߜ
 
pH Electrodes, Testers & Accessories  
Benchtop/Laboratory Meters  
Controllers, Calibrators, Simulators & Pumps  
Industrial pH & Conductivity Equipment  
DATA ACQUISITION  
ߜ
 
ߜ
 
ߜ
 
ߜ
 
ߜ
 
Data Acquisition & Engineering Software  
Communications-Based Acquisition Systems  
Plug-in Cards for Apple, IBM & Compatibles  
Data Logging Systems  
Recorders, Printers & Plotters  
HEATERS  
ߜ
 
ߜ
 
ߜ
 
ߜ
 
ߜ
 
Heating Cable  
Cartridge & Strip Heaters  
Immersion & Band Heaters  
Flexible Heaters  
Laboratory Heaters  
ENVIRONMENTAL  
MONITORING AND CONTROL  
ߜ
 
ߜ
 
ߜ
 
ߜ
 
ߜ
 
ߜ
 
Metering & Control Instrumentation  
Refractometers  
Pumps & Tubing  
Air, Soil & Water Monitors  
Industrial Water & Wastewater Treatment  
pH, Conductivity & Dissolved Oxygen Instruments  
M4250/0809  
Download from Www.Somanuals.com. All Manuals Search And Download.  

MotoSAT Stereo System D DP3 User Manual
Mustang Survival Life Jacket MD3091 User Manual
NEC Server 320Fd User Manual
NETGEAR Computer Drive 600B User Manual
Norcent Technologies Flat Panel Television LT 3290 User Manual
NuTone Ventilation Hood RF 59NRPSC User Manual
Optimus Stereo Receiver STA 3500 User Manual
Palsonic TV Converter Box 6860PFST User Manual
Panasonic Power Hammer EY6803 User Manual
Panasonic Scanner KV S5055C User Manual