Enhanced Series
For personal computers and work stations
ES550C / ES800C / ES1000C / ES1000C-RM / ES1500C /
ES1500C-RM
ES550C / ES800C / ES1000C / ES1500C
* ES1500C
Protection for small electronic equipment
The ESC series offer the highest power capacity and the best equipment protection around. Not only do they protect
against blackouts, sags and surges, but with the added feature of AVR (Automatic Voltage Regulator), these UPS
products ensure that only clean and safe currents reach your equipment.
What is AVR?
AVR is a feature that corrects under and over voltages without draining the battery, thus providing extended battery life
and, most important, allowing the UPS to provide high quality power during unacceptable voltage fluctuations.
Backup Time (Typical)
Features
* Easy battery replacement procedure
* 1050 Joules surge energy rating
* 4 hours battery recharge time
* AVR (automatic voltage regulator)
* Up to 8 battery backup outlets
* RJ11/RJ45 protection
ES550C
ES800C
ES1000C
ES1500C
1PC+1LCD 21 mins
1PC+1LCD 33 mins
1PC+1LCD 40 mins
1PC+1LCD 45 mins
* Smart power management software
Front Panel
Specifications
ES550C / ES800C
Model Name
Topology
On-battery Output Waveform
INPUT
ES550C
ES800C
ES1000C
ES1500C
A
B
C
D
Battery
Fault
Battery
Mode
AC
ON/OFF
Line-interactive
Simulated Sine Wave
Mode TEST/SILENCE
550VA / 330W
800VA / 480W
100 / 110 / 120Vac or 220 / 230 / 240Vac**
50Hz / 60Hz Auto Sensing
1000VA / 700W
1400VA / 980W
Maximum Capacity
Nominal Input Voltage
Nominal Input Frequency
Input Voltage Range
Input Short Protection
OUTPUT
C) AC Mode
D) On / Off, Test / Silence
A) Battery Fault
B) Battery Mode
Rated Voltage +/- 25%
Circuit Breaker (US), Fuse (IEC)
Circuit Breaker
ES1000C / ES1500C
Nominal Output Voltage
Output Voltage Regulation
Transfer Time
100 / 110 / 120Vac or 220 / 230 / 240Vac**
A
Battery
Fault
B
C
Battery
Mode
D
E
F
ON/OFF
Rated Voltage +/- 5% (on battery)
4 ms (typical)
Buck
Boost AC Mode
TEST/SILENCE
8 Battery backup (US)
8 Battery backup (IEC)
Number of Outlets
3 UPS outlets + 3 Surge protected outlets (US)
3 UPS outlets + 2 Surge protected outlets (IEC)
PROTECTION
A) Battery Fault
B) Buck
C) Battery Mode
D) Boost
E) AC Mode
F) On / Off, Test / Silence
Automatic Voltage Regulation (AVR)
Data Line Surge Protection
Surge Energy Rating
Normal Mode Noise Suppression
BATTERY
Yes
RJ11 / RJ45
1050 Joules
Full time EMI/RFI filtering
Rear Panel
User Replaceable Battery
Recharge Time to 90%
Audible Alarms
COMMUNICATION INTERFACE
Communication Port*
ENVIRONMENTAL
Operation Temperature
Storage Temperature
Audible Noise
PHYSICAL
Dimensions (Physical / Packing)
(in)
(L x W x H)
Weight (Net / Gross)
12V/7.2AH x 1
12V/34W x 1
12V/7.2AH x 2
12V/34W x 2
< 4 Hours
ES550C / ES800C
Battery mode / UPS fault / Overload
Communication
Port
RS232
Data Line
Protection
0°~40°C / 32°~104°F
-20°~60°C / -4°~140°F
< 40 dBA
Battery Backup
Outlets
Convenience
Outlets
14.9 x 5.5 x 7.9 / 19.2 x 10.6 x 12.8
378 x 140 x 201 / 487 x 270 x 326
31.1 / 33.3
14.1 / 15.7
12.7 x 4 x 6.5 / 16.1 x 7.7 x 10.6
322 x 102 x 165 / 410 x 195 x 268
14.1 / 16.1
Surge Protected
(mm)
(lbs)
(kg)
Outlets
Input
15.4 / 17.4
7 / 7.9
35.7 / 39.2
16.2 / 17.8
6.4 / 7.3
100V
110V
120V
220V
230V
240V
CONFORMANCE
Approvals
BSMI ; CE ; UL / cUL ; C-Tick, A-Tick ; GOST-R
Specifications are subject to change without notice.
* You can purchase RS232 to USB cable.
** See VS1000C on page 6
ES1000C / 1500C
Communication
Port
Data Line
Protection
IBM
Win
windows
SUN Solaris
HP-UX
SGI Irix
windows
2000 / XP
2003 / Vista
Novell Netware
Linux
FreeBSD
IBM OS/2
IBM AIX
Simulated
Sine Wave
95/98
ME/NT
Output
Breaker
Input
100V
110V
120V
220V
230V
240V
11.